Página 1
CITY OF DOVER, DELAWARE
PLANNING COMMISSION
Tuesday, January 19, 2021 at 7:00 PM
Virtual Meeting
AGENDA
Written comments are accepted via mail to City of Dover – Planning Commission, P.O. Box 475 Dover
DE 19903 and via email at CompPlan@dover.de.us.
VIRTUAL MEETING NOTICE
The Planning Commission Meeting for Tuesday, January 19, 2021 will be held only as a Virtual Meeting
using WebEx. Representatives of each Project Application will receive a specific invitation to attend this
meeting. Regular Planning Commission member participants will receive a specific invitation to attend
the meeting as a Panelist.
PUBLIC PARTICIPATION INFORMATION
City of Dover Planning Commission Meeting of Tuesday, January 19, 2021
Dial: 1-408-418-9388
Event number/Access code: 179 665 6580
Event password: DoverPC
Event Address: https://bit.ly/PCMeeting011921
If you are new to WebEx get the app now at https://www.webex.com/ to be ready when the
meeting starts. For problems accessing the meeting, please call the Planning Office at (302) 736-
7196.
CALL TO ORDER
PLEDGE OF ALLEGIANCE
ROLL CALL
ADOPTION OF AGENDA
APPROVAL OF MINUTES
1. Adoption of Minutes of December 21, 2020.
COMMUNICATIONS & REPORTS
1
Página 2
PLANNING COMMISSION - January 19, 2021 PAGE 2
Meeting Reminder: The next Planning Commission regular meeting date Tuesday, February 16,
2021 at 7:00 PM.
Update on City Council Actions
Department of Planning & Inspections Updates
2. Summary of Applications 2020
Education and Training Opportunities
3. University of Delaware: Institute for Public Administration - Training Opportunities
OPENING REMARKS CONCERNING MEETING PROCEDURES FOR APPLICATIONS
OLD BUSINESS
Request Extension of Planning Commission Approval: None
NEW APPLICATION
4. C-21-01 Cassidy Commons at 101-1001 Cassidy Drive - Public Hearing and Review of a
resubmission of an expired Conditional Use Site Plan for the construction of six (6) additional
manufacturing/warehousing buildings (in addition to the four (4) already constructed) for a
total of ten (10) 9,950 SF manufacturing/warehousing buildings on one parcel of land and other
associated site improvements at 101-1001 Cassidy Drive. The property is 10 acres ± and is
zoned M (Manufacturing Zone) and is subject to the AEOZ (Airport Environs Overlay Zone)
APZ I and Noise Zones A and B. The property is located on the south side of Lafferty Lane
west of Horsepond Road along a private drive known as Cassidy Drive. The owner of record is
Cassidy Commons, LLC. Property Address: 101-1001 Cassidy Drive. Tax Parcel: ED05-
077.00-01-28.04-000. Council District 2. This Plan was originally submitted as Conditional
Use Site Plan Application C-09-03 then superseded by C-11-04 M & L Ventures at Lafferty
Lane. C-11-04 received Conditional Approval by the Planning Commission in June 2011 and
as amended in February 2012 with Final Plan Approval granted on April 23, 2012. Four of the
originally proposed ten building were constructed, but due to a prolonged period of inactive
construction the Plan C-11-04 has since expired. Waivers Requested: Reduction of Bicycle
Parking, Partial Elimination of Curbing, and Partial Elimination of Sidewalk and
Consideration of a Performance Standards Review Application.
NEW BUSINESS
ADJOURN
Posted Agenda: January 8, 2021
THE AGENDA ITEMS AS LISTED MAY NOT BE CONSIDERED IN SEQUENCE. PURSUANT TO
29 DEL. C. §10004(e)(2), THIS AGENDA IS SUBJECT TO CHANGE TO INCLUDE THE ADDITION
OR THE DELETION OF ITEMS, INCLUDING EXECUTIVE SESSIONS, WHICH ARISE AT THE
TIME OF THE MEETING
2
Página 3
Item 1.
CITY OF DOVER PLANNING COMMISSION
DECEMBER 21, 2020
The Meeting of the City of Dover Planning Commission was held on Monday, December 21,
2020 at 7:00 PM as a Virtual Meeting using the phone/videoconferencing system WebEx due to
Delaware’s Declaration of the State of Emergency for COVID-19. The Meeting Session was
conducted with Chair Mrs. Maucher presiding. Members present were Mr. Adams, Mr. Roach,
Mrs. Malone, Mr. Hartman, Mrs. Lord, Mrs. Welsh, Dr. Jones and Mrs. Maucher. Mr. Baldwin
was absent.
Staff members present were Mr. Dave Hugg, Mrs. Dawn Melson-Williams, Mr. Julian
Swierczek, Mrs. Samantha Bulkilvish, Mr. Jason Lyon, Mrs. Tracey Harvey and Mrs. Kristen
Mullaney. Also present were Mr. Doug Barry, Mr. Dave Grayson and Ms. Jabria Allen.
Speaking from the public was Mr. Donny Legans.
APPROVAL OF AGENDA
Dr. Jones moved to approve the Agenda tonight, seconded by Mrs. Welsh and the motion was
unanimously carried 8-0 with Mr. Baldwin absent.
APPROVAL OF THE PLANNING COMMISSION MEETING MINUTES OF
NOVEMBER 16, 2020
Mrs. Welsh moved to approve the Planning Commission Meeting Minutes of November 16, 2020,
seconded by Mr. Adams and the motion was unanimously carried 8-0 with Mr. Baldwin absent.
COMMUNICATIONS & REPORTS
Mr. Hugg stated that the next Planning Commission regular meeting is scheduled for Tuesday,
January 19, 2021 at 7:00PM.
Mr. Hugg provided an update on the regular City Council and various Committee meetings held
on November 23 & 24, 2020 and December 14 & 15, 2020.
Mr. Hugg stated they did receive three requests in a timely manner on Comprehensive Plan
Amendments that Mrs. Melson-Williams will discuss with the Commission.
Mr. Hugg stated that in tonight’s packet, there are a number of course announcements from the
Institute of Public Administration which Planning Staff strongly recommend.
Mrs. Melson-Williams stated for the update on the implementation of the Dover 2019
Comprehensive Plan, Mr. Hugg mentioned that we had several Comprehensive Plan
Amendments Applications filed. The filing deadline as established by your adopted
Comprehensive Plan was December 15, 2020 for anyone seeking to make changes to the
Comprehensive Plan in either the text or the maps that are part of that document. They expected
three requests from the public and they will now begin a formal review process, ultimately
appearing before the Planning Commission and City Council for public hearings. The first step
for any Comprehensive Plan Amendment Request is for City Staff to submit those requests
through the PLUS process. So Staff, in the next few weeks, will be preparing that submission for
1
3
Página 4
Item 1.
CITY OF DOVER PLANNING COMMISSION DECEMBER 21, 2020
PLUS in order to meet their January 4, 2021 submission deadline and PLUS will hear that later
in the month of January. The action and the hearing on the Comprehensive Plan Amendments
and any associated applications, two of them also made requests for Rezoning, will be heard at
the February 2021 Planning Commission Meeting and then City Council action in March 2021.
There are three items and there will be information forthcoming on those when they are ready for
Planning Commission review in February. The second item is the Comprehensive Rezoning
Project. Staff continues to prepare what will be the list for consideration. With that, we have to
compare the City’s existing Zoning Map with the Land Development Plan Map that is part of the
Comprehensive Plan (that is Map 12-1) to identify where there is potential conflicts either in
zoning or if the zoning is deemed appropriate, whether there needs to be a map change in that
area. We have been through a fairly substantial, almost parcel by parcel review and are working
to take the next steps with that project. They will certainly have more information to report in
January on that. It is trailing a little bit behind our Comprehensive Plan Amendment process
which might be good so that it’s not confusing for the Commission members. That is something
that we do have to have complete by June 2021.
Mrs. Melson-Williams stated that the City Hall and City Buildings continue to be closed to the
public. Staff is working remotely when possible and/or different schedules to limit interaction
amongst staff to the best of our ability and still continue business operations. She would point
you to the City’s website for how to reach out to the various departments. Email continues to be
the best way to reach Planning Staff directly. She will let them know that this week. Christmas
Eve is considered a City holiday thanks to City Council action last week as is Christmas Day.
The following week, New Year’s Day is also a City holiday. In November, Mrs. Bulkilvish and
Mr. Swierczek both passed their AICP Certification tests and now can proudly display those
famous professional certifications that all Planners aspire to have with AICP after their names.
Mrs. Melson-Williams stated that included in the packet is the Meeting and Deadline Schedule
for 2021. They published it as a Draft because they want to do one last check to make sure the
dates are good. You can mark your calendar with the Planning Commission meeting dates for
next year. You will continue to meet on the third Monday of each month unless that Monday
happens to be a holiday and then you meet on the Tuesday of that same week. That happens in
both January and February.
Mrs. Melson-Williams stated that in the packet, there is a whole series of sessions that the
University of Delaware: Institute for Public Administration is presenting. For those of you that
have done these in the past, they used to be an in-person meeting but they have moved to a
virtual format. The exciting part is that they are free so please take advantage of that. Especially
our new Planning Commission members or if you have been at this for a bit and want a good
refresher, these are excellent presentations. They are typically 1.5 - 2 hours and they have
specific dates. The next one coming up is on January 22, 2021 and that is “Planning 101:
Planning Your Community’s Future.” It is a great introduction to planning. These are presented
virtually using Zoom so you get to listen to the speaker and see all of their slides but she doesn’t
believe that they have to see your face. They do encourage interaction with asking questions of
the presenters. A lot of the presenters are well versed in how things work in Delaware. If you
know David Edgell, he is a presenter at that first session. Our previous Planning Director, Ann
Marie Townshend is one of the presenters in the March session. We certainly encourage you to
2
4
Página 5
Item 1.
CITY OF DOVER PLANNING COMMISSION DECEMBER 21, 2020
go online and register. Once you register online, they will send you the direct link for the Zoom
meeting.
OPENING REMARKS CONCERNING DEVELOPMENT APPLICATIONS
Mrs. Melson-Williams presented the audience information on policies and procedures for the
Virtual Meeting using the WebEx system.
OLD BUSINESS
1) Requests for Extensions of Planning Commission Approval: None
NEW APPLICATIONS
C-20-04 Kid Clouds Child Day Care at 113 North West Street - Public Hearing and Review of a
Conditional Use application to establish a Large Family Day Care serving up to 12 children
within an existing building. The property is 0.558 acres and is zoned RG-1 (General Residence
Zone). The property is located on the east side of North West Street just north of Fulton Street.
The owner of record is the Solid Rock Baptist Church. Property Address: 113 North West Street.
Tax Parcel: ED-05-076.08-03-02.00-000. Council District 4. This property was previously
subject to Conditional Use Application C-16-01 The Gathering Place Large Family Daycare.
The application was granted Conditional Approval by the Planning Commission at their
February 2016 meeting, Final Plan Approval on April 18, 2016, and was in operation until
October 2018.
Mrs. Melson-Williams stated that they have not seen the applicant join the meeting at this time.
Planning Staff was going to try to reach out to her.
Mrs. Harvey stated that she called, texted and emailed the applicant and has not gotten a
response back.
Mrs. Melson-Williams stated that she is going to turn to Mr. Hugg for a decision. The
application was properly noticed and the public hearing would be this evening. Should we
proceed and then they could recess the hearing to their January meeting in hopes that the
applicant would be present? Responding to Mrs. Melson-Williams, Mr. Hugg stated that he
suggests that we move ahead to the next application and give the first applicant that much more
time to possibly attend tonight and then if they are not here, we can make a decision at that time.
Consideration of Application C-20-04 was deferred until later in the meeting.
C-20-05 Bay Pointe Apartments at 1080 and 1106 Bay Road - Public Hearing and Review of a
Conditional Use Site Plan Application and associated Lot Consolidation Plan to permit the
construction of two (2) Multiple Dwelling-Unit (Apartment) Buildings consisting of a three-story
39,750 SF building with 30 units and a three-story 30,864 SF building with 24 units for a total
of 54 apartment units and associated site improvements. The proposed Apartment buildings
require Conditional Use review in the C-4 zoning district. The three existing lots to be
consolidated total 3.302 +/- acres and are zoned C-4 (Highway Commercial Zone). The property
3
5
Página 6
Item 1.
CITY OF DOVER PLANNING COMMISSION DECEMBER 21, 2020
is located on the southwest side of Bay Road at the intersection with Lafferty Lane. The owner of
record is Patel Hospitality Properties. Property Addresses: 1080 and 1106 Bay Road and an
unaddressed parcel. Tax Parcel Numbers: ED-05-086.00-01-18-00-000, ED-05-086.00-01-19.00-
000, and ED-05-086.00-01-20.00-000. Council District 2. Waiver Request: Reduction of Arterial
Street Buffer and Elimination of Rear Emergency Access. For Consideration: Active Recreation
Plan and Request for Cash-in-Lieu of Recreation Area Construction.
Representatives: Mr. Doug Barry, Pennoni and Associates; Mr. Dave Grayson
Mr. Swierczek stated that this is a Conditional Use Site Plan Application for the construction of
two apartment buildings on two parcels of land that are on Bay Road at Lafferty Lane. The third
parcel is not addressed. A Parcel Consolidation would be part of this application as well. As a
Conditional Use Site Plan Application, the zoning is C-4 (Highway Commercial Zone) which
requires specific approval of the use by the Planning Commission. So that is something to note in
your motion. The applicant has submitted two waiver requests. One is for the reduction of the
Arterial Street Buffer that is specific to the frontage along Route 1. The piece of land where this
is proposed does not have any access to Route 1 as it is obviously a limited access road;
however; technically by Code it does have frontage on that road. There is a part of the proposed
development to the northwest of the site where the parking does slightly encroach into the
Arterial Street Buffer setback. The second waiver that they have submitted is for Rear
Emergency Access. This is a somewhat unique layout as the main entrances of the buildings
technically face internal to the site. There is one two-way access road that is shown in the
proposal providing access to the parking lots. The apartment buildings face internal towards that
parking lot and not outwards towards Bay Road. Planning Staff had suggested that they seek a
waiver request for Rear Emergency Access but they also wanted input from the Fire Marshal’s
Office. One key item for consideration is that there is also an Active Recreation Area
requirement. Any development of this scale with multiple dwelling units has a requirement that
the developer provide some type of active recreation outdoors for the tenants. Based on the
requirements as labeled in Code, there is the minimum of 10,000 SF of Active Recreation Area
required for this development. The developer had initially submitted plans not showing any
Active Recreation being provided. They have submitted Revised Site Plans that are shown right
now on the screen that show that they have extended a sidewalk that wraps from the multi-modal
path that they are providing along Bay Road into the site to provide some walking area for
tenants which is beneficial as this land does not actually have any pedestrian access to any other
adjacent properties. They also provided a picnic area on the site as well. Their Revised Active
Recreation that was submitted to the Parks and Recreation, as Mr. Hugg noted, was
recommended to move forward to the Planning Commission for your consideration. They are not
quite at the 10,000 SF and they would still have to submit a payment towards that Active
Recreation Fund but again, that is for the Commission’s consideration tonight as well.
They did provide renderings of the buildings. It wasn’t specifically labeled but you can see a
general idea. They have open staircases that face inward to the site. He believes that these
renderings only show one of the buildings but they would both be similarly built. As he noted,
they do provide a ten foot multi-modal path along the Bay Road frontage. There is a multi-modal
path on the other side of Route 1 that is not accessible from this area. They do not have
pedestrian access to any other sidewalks or neighboring parcels in the area so while Code does
4
6
Página 7
Item 1.
CITY OF DOVER PLANNING COMMISSION DECEMBER 21, 2020
require that pedestrian access be provided; it will not be connecting to anything, only to the
internal facilities on the site. They are showing one hundred twenty-four parking spaces which
would require seven bicycle parking spaces. They have indicated that they will be covering that
requirement.
Mr. Barry stated that he wanted to offer some things that were in the review commentary that we
might not have hit on. They realize that there were some minor inconsistencies with the
architectural renderings that they will work out prior to submitting a Building Permit. They were
minor details on how the buildings were going to look. With regards to the bedroom count, that
was one of the questions that the City posed, what they foresee with the fifty-four units is thirty-
six two-bedroom units and eighteen one-bedroom units. Also in the review commentary, the
developer is amenable to considering construction techniques that will mitigate noise as a
conditional approval.
Mr. Hartman stated that this property that is zoned C-4 (Highway Commercial Zone), it appears
to him that that’s the way it should be used. What the applicant is proposing here is a somewhat
isolated site where some substantial waivers have to be requested to make it even semi-livable.
He thinks that the waiver to reduce the green space of the active recreation area in an isolated
area like this is abysmal to the quality of life that the people who live there will have to
experience. A sidewalk and a picnic table does not compensate for the recreational area that
should be provided. More importantly, the Fire Marshal, himself, has said that he will not
support the waiver for the emergency access. That waiver and the waiver on the recreational
area, he believes, is enough for the Commissioners to consider denying this application.
Mrs. Lord questioned if there were one hundred twenty-seven parking spaces? Responding to
Mrs. Lord, Mr. Barry stated there are one hundred twenty-four spaces.
Mrs. Lord further questioned if that is enough to cover maximum capacity and visitors?
Responding to Mrs. Lord, Mr. Barry stated yes; the City requires two parking spaces per unit
with a residual ¼ space for visitors. That comes out to 2.25 spaces or for this application, one
hundred twenty-two spaces. So they are parking compliant.
Mrs. Lord questioned if each unit would get a ¼ of a space of visitor parking? Responding to
Mrs. Lord, Mr. Barry stated that was correct. That is even for the one bedroom units; they get
2.25 spaces also.
Mr. Swierczek stated that it is rounded up so if there was just to be two units that would require
five spaces. Responding to Mr. Swierczek, Mrs. Lord stated that she finds that a little
problematic only because many places have those visitors or family coming in and we have all
been to other apartments building or townhouses where you drive around forever trying to find a
place to park. Having a ¼ of a space per unit seems a bit small.
Mr. Swierczek stated that two spaces would be provided for the residents at each apartment unit
and then that ¼ space is the added bit extra. So, essentially every four apartments gets an added
space.
5
7
Página 8
Item 1.
CITY OF DOVER PLANNING COMMISSION DECEMBER 21, 2020
Mrs. Lord stated that you would have a two-bedroom apartment with two people and two cars
and they get ¼ visitors space. Responding to Mrs. Lord, Mr. Barry stated yes, that is assuming
that there are two people in the two bedroom units. Sometimes there is only one car.
Mrs. Lord stated that she is just pointing it out because it has always been a frustration of hers
when visiting people.
Dr. Jones stated that without repeating Mr. Hartman’s observations of this application, she
concurs whole heartedly with him regarding the two items, especially the Active Recreation Area
and the emergency exits.
Mrs. Welsh stated that she concurs with Dr. Jones and Mr. Hartman’s comments. In particular,
about the Fire Marshal’s review of this project. That seems to be a life safety issue and as far as
she can see that is paramount as far as what they are looking at here.
Mrs. Maucher opened the public hearing.
Mr. Swierczek stated that an email was received by a Mr. Richard Bubik and he communicated
via email that he was in favor of the project and he was happy to go on record saying that he was
welcoming it, wished it success and it seemed like a great use for the property.
Mrs. Maucher closed the public hearing.
Mr. Hartman moved to deny C-20-05 Bay Pointe Apartments at 1080 and 1106 Bay Road based
on the Zoning Ordinance, Article 10, Section 1.1, the lack of emergency accessibility there which
coincides with the Fire Marshal’s rejection of their waiver for the emergency access and Article
10, Section 1.2, this does not fit in with the character of C-4 (Highway Commercial Zone) as it is
an isolated area and the quality of life of the residents would be greatly affected, seconded by
Dr. Jones and the motion carried 8-0 by roll call vote with Mr. Baldwin absent. Mr. Hartman
voting yes; he wanted to add earlier that the package presented by the DAC and the Planning
Office and the applicant as well, was very well done and made it easy to understand. He is sorry
that he had to go against it. Mrs. Lord voting yes; she finds it troubling that the Fire Marshal
pointed out the limited access because to her that is a cost of life issue. Dr. Jones voting yes;
based upon her previous comments and comments from the other Commissioners. Mrs. Welsh
voting yes, she agrees with the issue of safety for fire access although it was a well done
presentation and that space would be very usable for something other than apartments. Mr.
Adams voting yes; primarily for the public safety issue. Mr. Roach voting yes; for the concerns
that the Fire Marshal has as far as the safety of the site. It was a very nice presentation and he
does feel as though it would help having apartments unlike some of the other Commissioners but
the safety of the people in the building are more important to him than having more apartments.
Mrs. Malone voting yes; her reasons are the emergency access issue and the Cash-in-lieu of
Active Recreation Area. Mrs. Maucher voting yes; the emergency access is a great concern. The
lack of Active Recreation Area and Cash-in-lieu of is an amenity of an apartment and people can
decide whether or not that is something that they need. And, if it’s not offered then they can go
look elsewhere.
6
8
Página 9
Item 1.
CITY OF DOVER PLANNING COMMISSION DECEMBER 21, 2020
Returning back to the other application C-20-04 due to the arrival of its representative.
C-20-04 Kid Clouds Child Day Care at 113 North West Street - Public Hearing and Review of a
Conditional Use application to establish a Large Family Day Care serving up to 12 children
within an existing building. The property is 0.558 acres and is zoned RG-1 (General Residence
Zone). The property is located on the east side of North West Street just north of Fulton Street.
The owner of record is the Solid Rock Baptist Church. Property Address: 113 North West Street.
Tax Parcel: ED-05-076.08-03-02.00-000. Council District 4. This property was previously
subject to Conditional Use Application C-16-01 The Gathering Place Large Family Daycare.
The application was granted Conditional Approval by the Planning Commission at their
February 2016 meeting, Final Plan Approval on April 18, 2016, and was in operation until
October 2018.
Representatives: Ms. Jabria Allen
Mrs. Harvey stated that this Conditional Use Site Plan review is to permit a Large Family Day
Care in the community room of an existing building that is being utilized as a church at 113
North West Street to be known as Kid Clouds Large Family Day Care. The property for the
proposed development is zoned RG-1 (General Residence Zone). The property was previously
subject to Conditional Use project C-16-01 The Gathering Place Large Family Day Care. It was
granted Conditional Use approval by the Planning Commission at the February 2016 Meeting
and was in operation until October 2018. Conditional Use Site Plan C-13-07 for the construction
of a two story community center building also on the property but addressed as 109 North West
Street was approved by Planning Commission at the August 2013 Meeting. It is adjacent to the
existing place of worship. The Conditional Use Site Plan C-13-07 included the construction of a
parking lot and tree plantings for the site so the requirement for tree planting and parking has
been met for the Day Care. The applicant’s submission states up to twelve children, infants and
toddlers 0-12 months only will be attending the Day Care with two adult attendees. The applicant
has submitted changes to the plans stating that the age of the children will go up to 24 months
and there will be three attendees. The project proposal for twelve children would be classified as
a Large Family Day Care by the Zoning Ordinance as it provides care for more than six children
but less than thirteen. Since the large family day care is proposing to operate in a community
room of a church, this review is considered a Conditional Use Plan Application. Since the
applicant indicated the age of the children attending the Day Care would be infants and toddlers
only up to 24 months, no outdoor play area will be required.
Mrs. Lord stated that there will be twelve children but it states infants only 0-12 months but then
she heard Mrs. Harvey say up to 24 months. Responding to Mrs. Lord, Ms. Allen stated yes, it is
actually going to be twelve children and infants ranging from 0-12 months. It is not 0-24 months;
it is 0-12 months.
Mrs. Lord questioned no toddlers? Responding to Mrs. Lord, Ms. Allen stated no toddlers.
Originally, they were going to accept toddlers but they have decided to keep it strictly infants.
Mrs. Lord stated that when she heard the toddler provision earlier and no outdoor play space, she
was concerned because we all know little kids need to go outside and run. Do you feel that two
7
9
Página 10
Item 1.
CITY OF DOVER PLANNING COMMISSION DECEMBER 21, 2020
people can handle twelve infants? Responding to Mrs. Lord, Ms. Allen stated no they cannot; so
there will be based on the number of children enrolled. If there are three infants then there will
be one teacher, if there are six infants then there will be two teachers, and if there are nine infants
there will be three teachers. The ratio is one teacher per three infants.
Mrs. Malone stated that she is confused because she thought that it was mentioned that they are
going to have children up to 24 months. Responding to Mrs. Malone, Ms. Allen stated that
originally they were but as of a week or two ago, they changed it back to just infants. She is
guessing that it wasn’t updated in the description that Mrs. Harvey read but it will only be 0-12
months.
Dr. Jones stated that she is concerned about the note stating that there will be one teacher and
one intern. Responding to Dr. Jones, Ms. Allen stated that originally the Day Care was only
planning to have four children. So it was going to be her and an intern who can be a family
member or a family friend. When she talked to the Fire Marshal, he told her that she could have
up to twelve children. Right now, it will be based off of ratio. The number of teachers will be
dependent on how many children attend the Day Care.
Dr. Jones stated that intern, to her, implies that it is someone who is in training who may come
and go. Responding to Dr. Jones, Ms. Allen stated that this is a family child care, it is not really a
day care center. It is going to be very intimate and very small. It says an “intern” but it is really
just a family friend who will be assisting her. She will be a qualified teacher but she will be listed
as an intern because she (Ms. Allen) would be in charge of the Large Family Day Care.
Mrs. Lord questioned if everyone is going to be CPR certified for infants? Responding to Mrs.
Lord, Ms. Allen stated yes.
Mrs. Lord questioned if there will be background checks done on employees? Responding to
Mrs. Lord, Ms. Allen stated yes.
Mrs. Maucher opened the public hearing.
Mr. Donny Legans – 139 N American Avenue Dover, DE 19901
Mr. Legans stated that his question is for the applicant. Is there any concern with the long term
vacant buildings in the area that the church or day care might have? Responding to Mr. Legans,
Ms. Allen stated no, there are no concerns.
Mrs. Lord stated that it sounds like you will not be taking the children outside because of their
very young age and because there is no playground or anything like that. Responding to Mrs.
Lord, Ms. Allen stated that when the weather permits, some days they will do walks in the
stroller.
Mrs. Lord questioned where they will be walking the children? Responding to Mrs. Lord, Ms.
Allen stated around the parking lot around the church but they won’t be going anywhere too far.
Mrs. Lord questioned if the applicant feels like it is a safe environment to take the children
8
10
Página 11
Item 1.
CITY OF DOVER PLANNING COMMISSION DECEMBER 21, 2020
outside? Do you feel like the environment is conducive to that? Responding to Mrs. Lord, Ms.
Allen stated that she feels it will be safe because it won’t be her alone with twelve infants; it will
be her alone with three. She will be in charge of three children and another teacher will be in
charge of three children.
Mrs. Maucher closed the public hearing.
Mr. Hartman thanked the applicant for undertaking this job. He thinks that it is very much
needed and he appreciates it.
Mrs. Maucher questioned if this was a Conditional Use that would limit the age of the children?
Is it a Conditional Use for twelve children 0-12 months of age or can it be changed later by the
applicant? Responding to Mrs. Maucher, Ms. Allen stated that there is not a limit on the age; she
just decided to do 0-12 months because it is just something that she has always wanted to do. She
just wanted to have a small intimate day care where there will be mainly infants. In the future, it
will not change unless she moves into a completely different building.
Mrs. Maucher questioned if the applicant would have to come back if she wanted to make that
change? Is our approval approving a Large Family Day Care strictly for children up to 12
months? Responding to Mrs. Maucher, Mrs. Melson-Williams stated that she thinks that since
this is a Conditional Use, in making any motion the Commission could certainly as a condition
of approval limit that age bracket if you wanted to. That would mean if for some reason in the
future she wanted to increase the age of the kids that she was servicing, that would then trigger
some type of outdoor play area and it would need to come back to the Commission for focusing
on services for that age group of children. She thinks that you are certainly within your means
since it is a condition to make that part of your review and approval process this evening.
Mrs. Lord moved to approve C-20-04 Kid Clouds Child Care at 113 North West Street with the
condition that it is only 0-12 months because there is not an outdoor playground and she is not
sure that it would be a safe area for an outdoor playground, seconded by Mrs. Malone and the
motion was carried 8-0 by roll call vote with Mr. Baldwin absent. Mrs. Lord voting yes. Dr.
Jones voting yes; this type of children care facility is very much in need. Mrs. Welsh voting yes.
Mr. Adams voting yes. Mr. Roach voting yes; we appreciate you taking your time to serve this
age group and also being careful enough to be providing for the safety of the children regardless
of the surrounding circumstances. Mrs. Malone voting yes; for reasons previously stated. Mr.
Hartman voting yes; he wishes the applicant the best of luck. Mrs. Maucher voting yes; she
concurs with the successful wishes.
NEW BUSINESS
Meeting adjourned at 8:21 PM.
Sincerely,
Kristen Mullaney
Secretary
9
11
Página 12
Item 2.
City of Dover, Delaware
Summary of Applications
2019 2020
2005 2006 2007 2008 2009 2010 2011 2012 2013 2014 2015 2016 2017 2018
Application
Type
Q1 Q2 Q3 Q4 Total Q1 Q2 Q3 Q4 Total
Board of
Adjustment
18 25 38 20 15 15 13 15 17 14 15 16 17 12 3 2 4 0 9 3 1 0 1 5
Annexations 6 10 4 3 1 0 0 1 3 0 1 3 0 2 1 0 0 0 1 2 1 0 0 3
Conditional
Use
9 8 7 14 8 5 7 6 11 6 4 5 6 5 0 2 5 1 8 1 0 2 2 5
Site Plans 39 49 66 43 29 33 23 20 21 24 16 24 33 12 8 4 8 5 25 1 3 4 6 14
Subdivisions 8 7 7 2 7 5 2 2 6 5 2 0 2 4 0 1 0 0 1 1 0 1 0 2
Rezoning 7 13 10 11 5 8 6 2 3 4 4 7 5 3 4 2 0 0 6 1 0 0 2 3
Miscellaneous 17 17 23 20 15 20 17 24 22 14 14 18 8 13 2 2 4 0 8 2 3 1 2 8
Unified Sign 1 0 1 3 1 0 2 2 3 1 2 4 2 0 0 0 0 0 0 0 0 0 0 0
Historic
District 3 9 7 4 4 11 5 7 5 6 8 6 4 3 1 0 3 0 4 1 0 0 1 2
Commission
TOTAL 108 138 163 120 85 97 75 79 91 74 66 83 77 54 19 13 24 6 62 12 8 8 14 42
*Summary of Applications through year end of 2020 including all 2020 Meetings of the Planning Commission, Board of Adjustment and Historic
District Commission and Administrative Plan Reviews.
12
Página 13
The Institute for Public Administration presents Item 3.
Planning 101: Planning Your
Community’s Future
COURSE INSTRUCTOR COURSE INSTRUCTOR
David Edgell, AICP Edward O’Donnell, AICP
Principal Planner Senior Fellow, IPA
Office of State Planning Coordination University of Delaware
COURSE INSTRUCTOR
Max Walton, Esq.
Partner
Connolly Gallagher, LLP
JANUARY 22, 2021 Planning 101 provides valuable information for
all elected officials who consider and act upon
comprehensive plans, land use and zoning matters,
10:00 a.m. to NOON .
and other growth issues. Planning and zoning
commissioners, board of adjustment members, and
those who take part in community planning and
VIA ZOOM MEETING land-development matters will enjoy this course.
Registration in advance is required. Course topics will include:
After registering, you will receive a
confirmation email with information
• Delaware planning and zoning statutory
about joining the webinar. requirements
• The elements of a comprehensive plan
REGISTER ONLINE • The basics of land use control
www.bidenschool.udel.edu/ • The role of the planning & zoning commissioner
ipa/events/upcoming This session qualifies for certificate credit in the
Academy for Excellence in Local Government
Leadership and the Delaware Planning Education
Program.
13
Página 14
Item 3.
The Institute for Public Administration presents
Introduction to Land-Use Law,
the Constitution, and Takings
COURSE INSTRUCTOR
Max Walton, Esq.
Partner
Connolly Gallagher, LLP
FEBRUARY 12, 2021 This course focuses on Land Use Law in Delaware.
It begins a review of the basic principles governing
land-use law. Topics include police power, delegation
10:00 a.m. to NOON
Check-in begins at 8:30 a.m.
of authority, nuisances, due process, equal protection,
just compensation, vagueness, and vested rights.
Participants will then learn about Delaware court
decisions affecting local land use.
VIA ZOOM MEETING
Course topics will include:
Registration in advance is required. • Basic terms and concepts
After registering, you will receive a
confirmation email with information • A summary of tools
about joining the webinar.
• Zoning, subdivision, and site-plan review
• Other approaches to land-use control
REGISTER ONLINE This session qualifies for certificate credit in the
www.bidenschool.udel.edu/ Academy for Excellence in Local Government
ipa/events/upcoming Leadership and the Delaware Planning Education
Program.
14
Página 15
Item 3.
The Institute for Public Administration presents
Introduction to
Land Use Administration
COURSE INSTRUCTOR COURSE INSTRUCTOR
Ann Marie Townshend, AICP Savannah Edwards
City Manager Planner, Municipal Department
City of Lewes AECOM
March 5, 2021 Introduction to Land Use Administration focuses
on the principal strategy for implementing
comprehensive plans.
10:00 a.m. to NOON
Check-in begins at 8:30 a.m.
Course topics include:
• Zoning, subdivision, and land-use codes and
how they are linked to comprehensive plans
VIA ZOOM MEETING • Typical contents of land-use, zoning, and
subdivision codes
Registration in advance is required.
After registering, you will receive a • Procedures and issues governing changes to
confirmation email with information the zoning map
about joining the webinar.
• Issues involved in the day-to-day administration
of land-use codes
REGISTER ONLINE This session qualifies for certificate credit in the
www.bidenschool.udel.edu/ Academy for Excellence in Local Government
ipa/events/upcoming Leadership and the Delaware Planning Education
Program.
15
Página 16
Item 4.
City of Dover
DATA SHEET FOR CONDITIONAL USE SITE PLAN REVIEW
DEVELOPMENT ADVISORY COMMITTEE MEETING OF January 6, 2021
PLANNING COMMISSION MEETING OF January 19, 2021
Plan Title: Cassidy Commons at 101–1001 Cassidy Drive, C-21-01
Plan Type: Conditional Use Site Plan
Location: South side of Lafferty Lane west of Horsepond Road along a private
drive known as Cassidy Drive
Tax Map #: ED-05-077.00-01-28.04-000
Owner/Applicant: Cassidy Commons, LLC
Site Area: 10 acres +/-
Zoning: M (Manufacturing Zone)
AEOZ (Airport Environs Overlay Zone)
APZ I (Accident Potential Zone I)
Noise Zone A
Noise Zone B
Proposed Use: Wholesale Storage and Warehouses
Manufacturing
Building Contractor’s Yards
Building Area(s): Buildings 1-4 individually (constructed): 9,950 SF
Building 6-10 individually (to be constructed): 9,950 SF
Total Area: 99,500 SF
Off Street Parking: Required – 125 spaces
Constructed – 52 spaces with Buildings 1-4
Additional Proposed – 78 spaces
Sewer & Water: City of Dover
Waiver Requests: Partial Elimination of Sidewalk
Partial Elimination of Upright Curbing
Elimination of Bicycle Parking
For Consideration: Performance Standards Review Application
P. O. Box 475 Dover, DE 19903
Community Excellence Through Quality Service 16
Página 17
Item 4.
City of
Dover
CITY OF DOVER Planning
Office
DEVELOPMENT ADVISORY COMMITTEE
APPLICATION REVIEW COMMENTARY
D.A.C. MEETING DATE: January 6, 2021
APPLICATION: Cassidy Commons at 101-1001 Cassidy Drive
FILE #: C-21-01 REVIEWING AGENCY: City of Dover Planning
CONTACT PERSON: Julian Swierczek, AICP, Planner I PHONE #: (302) 736-7196
I. PLAN SUMMARY
This application is for review of a resubmission of an expired Conditional Use Site Plan
Application to permit the construction of six (6) additional manufacturing/warehousing buildings
(in addition to the four (4) already constructed) for a total of ten (10) 9,950 SF
manufacturing/warehousing buildings on one parcel of land and other associated site
improvements at 101-1001 Cassidy Drive. The property is 10 acres ± and is zoned M
(Manufacturing Zone) and is subject to the AEOZ (Airport Environs Overlay Zone) APZ I and
Noise Zones A and B. The property is located on the south side of Lafferty Lane west of
Horsepond Road along a private drive known as Cassidy Drive. The owner of record is Cassidy
Commons, LLC. Property Address: 101-1001 Cassidy Drive. Tax Parcel: ED05-077.00-01-
28.04-000
Previous Applications:
This Plan was originally submitted as Conditional Use Site Plan Application C-09-03 then
superseded by C-11-04 M & L Ventures at Lafferty Lane. C-11-04 received Conditional
Approval by the Planning Commission in June 2011 and as amended in February 2012 (related
to timing of Road construction) with Final Plan Approval granted on April 23, 2012. Four of the
originally proposed ten (10) buildings were constructed, but due to a prolonged period of
inactive construction the Plan C-11-04 has since expired.
Preliminary Land Use Services Review (PLUS)
A development application for this property was reviewed on April 21, 2008 by the Preliminary
Land Use Services as part of the original Application (C-09-03) submitted by the Applicant and
approved by the Planning Commission in March of 2009. The PLUS Review is required by a City
of Dover Memorandum of Understanding (MOU) for certain types of projects. This MOU requires
that non-residential development of over 75,000 S.F. complete the PLUS Review process prior to
application submission. The applicant’s response to the PLUS letter from 2008 is on file at the
Planning Office. As the remainder of the project does not meet that minimum 75,000 SF threshold,
the applicant did not need to resubmit for a PLUS review for this Application C-21-01.
17
Página 18
Item 4.
C-21-01 Cassidy Commons at 101-1001 Cassidy Drive
DAC Report of January 6, 2021
Page 2
II. PROJECT DESCRIPTION
The subject property is located to the south of Lafferty Lane, with Bay Road and Horsepond
Road at some distance from the subject site. The applicant is resubmitting a previously approved
Conditional Use Site Plan which itself is proposing to construct the remaining six (6) one-story
structures measuring 9,950 SF each to be utilized primarily for the following uses: wholesale
storage and warehouses, manufacturing, and building contractor’s yards. These six (6) proposed
structures are in addition to the four (4) already built per Conditional Use Site Plan Application
C-11-04 Land of M&L Ventures. No specific type of manufacturing use has been identified for
the six (6) new buildings proposed.
Planning Staff notes that this project is returning to the Planning Commission as the previously
approved Conditional Use Site Plan C-11-04 Lands of M&L Ventures has expired. This previous
Plan C-11-04 was granted approval by the Planning Commission on June 20, 2011 and
established a plan for construction of ten warehouse/storage buildings on the property. Final
Plan approval was granted April 23, 2012 and four of the buildings have been constructed, each
with multiple tenant spaces. The Conditional Use Plan approval for the unbuilt six (6) other
warehouse buildings is considered expired as construction has not been continuous. This new
Conditional Use Application has been submitted for review by the Planning Commission in
order to continue construction.
Neighboring properties along Lafferty Lane are also zoned M (Manufacturing Zone). The
property immediately to the east and south is currently undeveloped, as is the property
immediately to the west. The property across Lafferty Lane to the north also remains
undeveloped.
III. ZONING REVIEW
M (Manufacturing Zone)
The application is a Conditional Use Site Plan for the proposed construction of a series of
warehouse style buildings for multiple tenants. Manufacturing, building contractor’s yards, and
wholesale storage and warehousing buildings in the M Zone are Conditional Uses which require
approval from the Planning Commission. (Zoning Ordinance, Article 3 Section 19.1)
Article 3 Section 19.1 Manufacturing zone (M)
19.1 Uses permitted. No building or premises shall be used, and no building or part of a building shall
be erected, which is arranged, intended or designed to be used, in whole or in part, for any purpose,
except the following, and conditional upon approval as to use by the planning commission in
accordance with the provisions of article 10, section 1 and in accordance with performance standards
procedure as set forth in article 5, section 8:
19.11 Manufacturing, assembling, converting, altering, finishing, cleaning or any other processing,
handling, or storage of products or materials involving the use of only oil, gas or electricity for fuel.
19.12 Research, design and development laboratories.
19.13 Wholesale storage and warehousing.
19.14 Building contractors' yards.
19.15 Public utilities uses.
18
Página 19
Item 4.
C-21-01 Cassidy Commons at 101-1001 Cassidy Drive
DAC Report of January 6, 2021
Page 3
19.16 Ministorage facilities, subject to the following regulations:
(a) No unit shall be placed within 30 feet of any other structure on the lot or a residential
property line.
(b) No outside storage, except for recreational vehicles, boats or personal automobiles
when completely screened from view and parked in specifically approved locations.
Parking for these vehicles shall not count toward the required parking set forth in
subsection (e) below.
(c) No individual unit may be used for retail, garage sale or any other commercial
activities.
(d) No storage of flammable, explosive, corrosive or other hazardous products may occur
in the individual unit.
(e) Parking must be provided at a ratio of one space for each 25 rental units, plus a
minimum of three spaces for an office outside of the enclosure. One row of parallel parking
is permitted between buildings at a ratio of one space per 25 feet.
(f) All other bulk requirements of this ordinance are met.
This Conditional Use Site Plan is subject to the requirements of Article 10 §1 further discussed
below.
With Conditional Use Site Plan applications, the Planning Commission reviews the proposed
project to determine whether or not the intended use is appropriate in type and scale for the
immediate neighborhood. The Commission must also consider whether or not the proposed use
will have an adverse impact on the future orderly development of the surrounding area. The
following sections of the Zoning Ordinance which relates to the role of the Commission in
reviewing Conditional Use Site Plan applications are particularly relevant when reviewing this
application:
Article 10 §1.1 Accessibility for emergency response. That all proposed structures, equipment or
material shall be readily accessible for fire, ambulance, police, and other emergency response;
Article 10 §1.2 Harmony of location, size and character. That the proposed use shall be of such
location, siz, and character that, in general, it will be in harmony with the appropriate and orderly
development of the zone in which it is proposed to be situated and will not be detrimental to the
orderly development of adjacent properties in accordance with the zoning classification of such
properties;
AEOZ (Airport Environs Overlay Zone)
The application is subject to the AEOZ (Airport Environs Overlay Zone): Noise Zones A and B,
and APZ I (Accident Potential Zone I) whose requirements may be found in the Zoning
Ordinance, Article 3 Section 22. Article 3 Section 22.6 provides a Land Use Compatibility Table
that specifically lays out permitted as well as restricted uses within the various Airport Environs
Overlay Zones. The site is located within Noise Zone A (65dB-69dB) and Noise Zone B (70dB-
74dB), and within Accident Potential Zone I (APZ I). The location of the property in the APZ I
may limit the types of manufacturing allowed. The Noise Zones may require an interior noise
level reduction of twenty-five (25) decibels or more.
The proposed land uses (including any tenants within the buildings) must comply with the
permitted uses of the M (Manufacturing) Zoning District (Article 3 §19) and the Land Use
Compatibility Table of the AEOZ (Article 3 §22.6). The application generally meets the
19
Página 20
Item 4.
C-21-01 Cassidy Commons at 101-1001 Cassidy Drive
DAC Report of January 6, 2021
Page 4
requirements of the M Zone for the proposed uses. However, as each specific tenant is identified,
the use must be reviewed through a Permit Review process for compliance with the M Zone and
the AEOZ Land Use Compatibility Table.
IV. PARKING SUMMARY
The parking requirement for most uses in the M (Manufacturing Zone) is based on a rate of one
parking space per 800 square feet of floor area or one parking spaces per employee, per largest
working shift (if greater than the requirement under the floor area calculation). Based on a total
floor area of 99,500 SF the facility would require 125 parking spaces. The plan notes a total of
130 parking spaces. The Plan shows a parking area consisting of 26 parking spaces between each
paired sets of buildings.
Loading Berths
Article 6 Section 4.2 of the Zoning Ordinance states that for manufacturing, wholesale, or
storage uses in the M or IPM zone, and for buildings in excess of 150,000 square feet in any
zone, sufficient off-street loading berths shall be provided. Staff will determine the sufficiency of
the loading berths after reviewing written documentation from the applicant through the site plan
review process. The Applicant does not currently note any specific loading area(s) on the Plan
submitted.
The applicant had noted on the previous submission (C-11-04) that the proposed development
will not be utilized by large semi-trucks. The applicant will however still need provide a written
description of all proposed activity to take place on site with this current submission, before
Planning Staff may determine the sufficiency of the proposed loading berths.
Waiver Request: Bicycle Parking
Bicycle parking shall be provided for parking spaces at a rate of one (1) bicycle parking space
for every twenty (20) parking spaces. Based on the 130 parking spaces provided, seven (7)
bicycle spaces are required. The Plans submitted note two (2) Bicycle Parking spaces being
provided between Buildings 1 and 2, but do not appear to be noted anywhere else on the site
Plan.
The Planning Commission may waive the requirement for the bicycle parking if it is
demonstrated that bicycle parking would not be appropriate for safety reasons or due to the
nature of the use of the site. The Applicant has submitted a written waiver request for the
elimination of bicycle parking for consideration by the Planning Commission. The request notes
the belief of the Applicant that due to the type of tenants planned, and the general remote
location of the site in relation to other developed areas, meeting the full minimum requirement of
seven (7) bicycle parking spaces would not be necessary. The Planning Commission previously
approved the waiver to eliminate bicycle parking as a part of the previous application C-11-04.
V. SITE CONSIDERATIONS
Access
The property is accessed via Cassidy Drive, a private drive constructed as part of the original
20
Página 21
Item 4.
C-21-01 Cassidy Commons at 101-1001 Cassidy Drive
DAC Report of January 6, 2021
Page 5
approval of Conditional Use Site Plan C-11-04. The drive provides two-way access off of
Lafferty Lane, a State maintained road; this entrance was constructed under a previous Entrance
Plan approval from DelDOT. Cassidy Drive currently has only been constructed only up to and
providing access to Building 4. This drive was originally approved and is still shown on the Plan
to be constructed all the way through the length of the site to Building 10 at the rear (southeast
end) of the property. It is noted on the Site Plans submitted that this drive is to remain private,
and not be dedicated to the City.
There is also shown a proposed street (named Construction Drive) on the plans submitted that
was to provide cross-access to the adjoining properties. This street was initially proposed to
facilitate access to any potential future developments on the sites immediately to the east and
west of the subject site and become part of a larger street network in the general area. Previously,
the Planning Commission revised the timeframe for construction of this street requiring it to be
constructed prior to Building 7. Construction Drive was shown labeled as cross-access easement
and as a proposed 60 ft. right-of-way on a Record Plan recorded in April 2012 (KCRD Plat Book
117 page 56). As depicted on the current C-21-01 Plans, this street Construction Drive is still
shown as proposed. The intentions of the applicant must be clarified as to if it will be privately
maintained or constructed to be ultimately dedicated to the City of Dover.
Lighting
Exterior building wall-mounted lighting is shown along the front of each of the buildings (the
“front” being the elevation of each building facing the parking areas). There does not appear to be
any pole lighting shown, either in the parking areas, or along Cassidy Drive.
Dumpsters
Industrial/warehousing buildings require one (1) dumpster pad for the first 40,000 S.F. of
building area and one (1) for each additional 40,000 S.F. of building area or a fraction thereof.
Based on this calculation one (1) dumpster pad may be required for each building. Based on this
calculation ten (10) dumpsters are required. The Site Plan currently indicates ten (10) dumpster
pads. The method of private trash collection needs to be identified on the plan. A dumpster
enclosure detail shall be provided on the plan to ensure that the architectural components of the
Dumpster enclosures match the construction materials of the proposed buildings.
Sidewalks
Waiver Request: Elimination of Sidewalk
Sidewalk is required along all street frontages. Sidewalk appears to have been constructed along
Lafferty Lane. Sidewalk is also shown being provided along both sides the cross-access
connector street of Construction Drive. Furthermore, sidewalk is provided along the east side of
Cassidy Drive. A written waiver request for the elimination of sidewalk along the west side of
Cassidy Drive was approved by the Planning Commission for the previous submission of this
Site Plan submission (C-11-04).
The C-21-01 Plans submitted similarly show sidewalks along all street frontages except for the
western side of the privately maintained Cassidy Drive. The Applicant has submitted a written
waiver request from the requirements for a sidewalk along the western side of Cassidy Drive for
consideration by the Planning Commission. The request notes the existence of sidewalk along the
21
Página 22
Item 4.
C-21-01 Cassidy Commons at 101-1001 Cassidy Drive
DAC Report of January 6, 2021
Page 6
eastern side of Cassidy Drive already planned, as well as the limited space to accommodate a
sidewalk along the western side of Cassidy Drive, as reasons for the request.
Administrative Waiver Request: Partial Elimination of Upright Curbing
The parking areas and access drives are required to be curbed with upright curbing (Zoning
Ordinance, Article 6 §3.6). Curbing is provided along the east side of Cassidy Drive and the
cross-access connector street. Planning Staff can consider a Waiver from the requirements for
Upright Curbing, provided the Applicant can demonstrate sufficient need. A written waiver
request for the elimination of curbing has been submitted, and subsequently granted by Planning
Staff. The request specifically notes the necessity for the waiver so as to help facilitate sheet
water flow as part of the approved stormwater management plan.
It is noted that the Planning Commission previously approved the waiver to allow for the
elimination of upright curbing and the use of depressed curbing as part of a previous application
(C-11-04). This Waiver however no longer needs to be considered by the Planning Commission,
but rather can be reviewed administratively by Planning Staff.
VI. BUILDING ARCHITECTURE
The proposed buildings will be a metal building with siding and a stone watertable feature. The
buildings will have pitched roofs. The buildings will have bay doors with an awning and window
over and next to the door. The proposed six (6) buildings to be constructed under this plan
resubmission appear to be of the same format and design of the four (4) buildings already
constructed.
VII. TREE PLANTING AND LANDSCAPE PLAN
Tree Planting Requirements
The Zoning Ordinance further requires a tree planting/landscape plan for at a rate of one tree per
3,000 SF of development area. Based on the size of the site 146 trees are required. The Plan
notes 146 trees being provided; however, the Tree Planting Plan appears to only show 145 trees.
The trees are located throughout the development with concentrations along the proposed access
road, and the property boundary. The trees are a mixture of deciduous trees and evergreen trees.
The trees include White Pines and Red Sunset Maple trees.
Planning Staff notes that the site must maintain compliance and achieve compliance with the 146
trees shown on the Plans. As trees had been previously provided on the site, the applicant must
ensure that their overall health is maintained. If any already planted trees have since been
removed, new ones must be provided to ensure continued compliance.
VII. PERFORMANCE STANDARDS REVIEW
Uses in the M Zone are subject to the Performance Standards Procedure set forth in the Zoning
Ordinance, Article 5, Section 8.1 and 8.2 and referenced sections.
Article 5 §8.1 Dangerous and objectionable elements. No land or building in any zone shall be
used or occupied in any manner so as to cause any one or more of the following conditions to
exist and to be dangerous, injurious, noxious or offensive beyond the boundaries of such
premises in such a manner or in such amount as to adversely affect the reasonable use of the
surrounding area or adjoining premises: Fire, explosive or other hazard; noise, or vibration;
smoke, dust, odor or other form of air pollution; heat, cold, dampness or electromagnetic
22
Página 23
Item 4.
C-21-01 Cassidy Commons at 101-1001 Cassidy Drive
DAC Report of January 6, 2021
Page 7
disturbance; glare, liquid or solid refuse or waste; traffic congestion causing roadways or
intersections in the surrounding highway network to fall below acceptable levels of comfort and
convenience; or other substance, condition or element (referred to hereinafter as "dangerous or
objectionable elements"), provided that any use permitted or not expressly prohibited by this
ordinance may be undertaken and maintained if it conforms to the regulations of this section
limiting dangerous and objectionable elements at the point of the determination of their existence.
The project’s compliance with a series of performance standards for the “dangerous and
objectionable elements” had previously considered by the Planning Commission. The “dangerous
and objectionable elements” are as follows:
• Fire and explosion hazards (activities with and storage of)
• Radioactivity or electromagnetic disturbance
• Noise (sound pressure level)
• Vibration
• Smoke
• Odors (Odorous gases or odorous matter)
• Fly ash, dust, fumes, vapors, gases and other forms of air pollution
• Glare (from lighting or high temperature processes)
• Liquid or solid wastes
• Traffic congestion (Level of Service E)
The project cannot cause the above conditions to exist so that they adversely affect the
surrounding areas or adjoining properties. The specific limits of each performance standard are
described in the Zoning Ordinance. Where the performance standards conflict with regulations
established by other state or local agencies such as the Delaware Department of Natural
Resources and Environmental Control (DNREC), the more restrictive regulations apply.
As part of this procedure, a Performance Standard Review Application is required to accompany
this Plan submission for review and approval. The Applicant has submitted a Performance
Standard Review Application letter indicating how the proposed development would restrict the
emission of dangerous and objectionable elements detailed in Article 5, Section 8.5.
VIII. CITY AND STATE CODE REQUIREMENTS:
The subject proposal has been reviewed for code compliance, plan conformity, and completeness
in accordance with the agency’s authority and area of expertise. The following items have been
identified as elements which need to be addressed by the applicant:
1) Sidewalk/pathway must be provided along the entire western side of Cassidy Drive in
accordance with the Zoning Ordinance unless a Waiver is granted by the Planning
Commission. A written Waiver Request has been submitted by the applicant for
consideration and approval by the Planning Commission in order to eliminate the sidewalk
along the western side of Cassidy Drive.
2) Bicycle Parking must be provided at a rate of one (1) space for every twenty (20) vehicle
parking spaces in accordance with the Zoning Ordinance (seven bicycle parking spaces)
unless a Waiver is granted by the Planning Commission. A written Waiver Request has been
23
Página 24
Item 4.
C-21-01 Cassidy Commons at 101-1001 Cassidy Drive
DAC Report of January 6, 2021
Page 8
submitted by the Applicant for consideration and approval by the Planning Commission in
order to reduce the number of bicycle parking spaces to be provided.
3) Upright Curbing must be provided in accordance with the Zoning Ordinance unless an
Administrative Waiver is granted by Planning Staff. A written Waiver Request was
submitted by the Applicant to Planning Staff which has granted an Administrative Waiver as
they have sufficiently demonstrated that there is sufficient need related to stormwater
management design for such a Waiver to be granted.
4) A Performance Standard Review Application is required to accompany this Plan submission
for review and approval by the Planning Commission. The applicant has submitted a
Performance Standard Review Application letter to the Planning Office indicating how the
proposed development would restrict the emission of dangerous and objectionable elements
detailed in Zoning Ordinance, Article 5, Section 8.5.
5) The Project Data column must be updated per the actions of the Planning Commission and as
follows:
a) Update AEOZ (APZ I and Noise Zones A and B).
b) Add property addresses.
c) Add notes regarding the actions taken on each Waiver Request.
6) Please note that a minimum of 146 trees are required for the overall site; however, the plans
submitted appear to only show 145 trees being provided. Please revise to show compliance
with minimum Tree Planting Requirements as laid out in the Zoning Ordinance.
7) Clarify the intent to provide a cross-access street allowing access to the properties immediately
east and west of the subject site shown to be between Buildings 6 and 7. Clarify the status and
intended use of the street (Construction Drive) shown to be between Buildings 6 and 7.
a) A previous Record Plan was approved and recorded in relation to the previous application
C-11-04, but it is not certain as to whether the road/street is to be established as right-of-
way, or simply as a cross-access easement.
b) Similarly, note whether the road/street is to be dedicated or privately maintained. If this is
right-of-way to be dedicated to the City, then a Record Plan will be required to establish
the area of dedicated right-of-way.
8) Please note that the plans submitted are a copy of the previously approved Final Plans for
Conditional Use Site Plan C-11-04. Please note on the Plans, the status of all Site
improvements already made (Current Conditions Plan Sheet) as well as a separate Sheet for all
Site Improvements to still be carried out (Proposed Site Plan Sheet).
9) Please identify the locations of all proposed parking spaces in the format constructed
(Buildings 1-4 have angled parking), and how many are to be handicapped parking spaces.
10) If further Bicycle Parking Spaces are proposed beyond the two (2) identified, please note them
on the Plans.
24
Página 25
Item 4.
C-21-01 Cassidy Commons at 101-1001 Cassidy Drive
DAC Report of January 6, 2021
Page 9
11) Please identify the location of any dumpsters and note details of any proposed dumpster
enclosures. Please note as well that Private Trash Collection is to be provided.
12) Clarify the operation of loading spaces on the site. Information in the various narrative
provided seem to indicate most activity as internal to the buildings.
13) Clarify the location of curbing on the site on all plan sheets.
14) Provide construction details for the following items but not limited to: barrier free sidewalk,
dumpster pad, curbing, traffic control signage, lighting fixtures, handicap signage, bike racks,
etc.
VIII. RECOMMENDATIONS SUGGESTED AS CONDITIONS OF APPROVAL TO MEET
CODE OBJECTIVES:
In accordance with the Zoning Ordinance, Article 10 §1, the Planning Commission in
considering and acting upon Conditional Use Plans may prescribe appropriate conditions and
safeguards so that the public health, safety, and welfare, the comfort and convenience of the
public in general, and the residents of the immediate neighborhood in particular shall be taken
into consideration. These safeguards may to the maximum extent possible further the expressed
intent of the Zoning Ordinance and the accomplishment of several objectives in particular listed
in subsections 1.1 to 1.3.
1) Recommendation on Waiver Requests:
a) Elimination of Sidewalk: A written Waiver Request has been submitted by the Applicant
demonstrating the need for a Waiver Request to be granted by the Planning Commission.
Planning Staff recommends approval of the Waiver Request, as the Applicant has noted
the limited space to accommodate said sidewalk on the west side of Cassidy Drive due to
the stormwater management plan for the site. The Applicant will still provide a sidewalk
along the eastern side of Cassidy Drive. Staff again notes that the Planning Commission
had previously approved a similar Waiver Request for Application C-11-04 and portions
of the approved stormwater management plan for the site have been implemented with the
construction of Buildings 1-4.
b) Reduction in Minimum Required Bicycle Parking Spaces: A written Waiver Request has
been submitted by the Applicant demonstrating the need for a Waiver Request to be
granted for consideration of the Planning Commission. Staff recommends approval as the
Applicant has noted that the intended uses on the site, as well as the relative remoteness of
the location, will likely not encourage many to bike to the property. If a tenant finds the
need for bicycle parking to accommodate their employees or visitors, then consideration
of placement can occur.
c) Partial Elimination of Upright Curbing: An Administrative Waiver Request was submitted
and consequently granted by Planning Staff due to the stormwater management plan
approved and under implementation for the site. The Request noted the need to eliminate
the curbing so as to better accommodate sheet-flow for overall stormwater management.
25
Página 26
Item 4.
C-21-01 Cassidy Commons at 101-1001 Cassidy Drive
DAC Report of January 6, 2021
Page 10
2) Consideration of Performance Standards Review Application: Planning Staff recommends
approval of the Performance Standards Review, believing it sufficiently demonstrates the
intent to comply with the restriction as provide in Zoning Ordinance, Article 5 Section 8.1
and 8.2.
3) Any uses of the site, buildings, and individual tenant spaces within the buildings are subject
to compliance with the allowable uses of the M (Manufacturing Zone) and the AEOZ
(Airport Environs Overlay Zone) Land Use Compatibility Table. Evaluation of each use will
occur as part of the Permit process for construction activity or for establishment of a use and
also as part of the Business Licensing program. Currently, the Code Enforcement Division is
following-up on potential lack of compliance issues observed by the City Fire Marshal.
4) Status of Construction Drive (Proposed Street): Clarification is needed regarding the
proposed street or cross-access drive located between Buildings 6 and 7. The developer
should clarify if they intend to build this as a privately maintained drive or as a public street
for dedication to the City. Planning Staff recommends that this street/drive be constructed
prior to the issuance of Building 7. It begins to establish part of what could become a larger
circulation network for this area on the south side of Lafferty Lane as there are vacant lands
that could see future development.
IX. ADVISORY COMMENTS TO THE APPLICANT:
1) The Planning Commission should act upon the request for waivers as part of any motion
regarding this project application, or as a separate motion as necessary. Note: All waivers
are at the discretion of the Planning Commission. The Commission may approve or deny
waiver requests.
2) In the event, that major changes and revisions to the Conditional Use Site Plan occur in
the finalization of the Conditional Use Plan contact the Department of Planning and
Inspections. Examples include relocation of site components like paving and increases in
floor area. These changes may require resubmittal for review by the Development
Advisory Committee, Planning Commission, or other agencies and commissions making
recommendations in regard to the Plan.
3) Following Planning Commission approval of the Conditional Use Site Plan, the Plan
must be revised to meet all conditions of approval from the Development Advisory
Committee or as otherwise noted. A Check Print must be submitted for review by
Planning Office Staff and the other commenting agencies. Upon determination that the
Plan is complete and all agency approvals have been received, copies of the Plan may be
submitted for final endorsement (Final Plan Approval).
4) Other agencies and departments which participate in the Development Advisory
Committee may provide additional comments related to their areas of expertise and code
requirements.
26
Página 27
Item 4.
C-21-01 Cassidy Commons at 101-1001 Cassidy Drive
DAC Report of January 6, 2021
Page 11
5) For building new construction, the requirements of the building code and the fire code
must be complied with. Consult with the Chief Building Inspector and City of Dover Fire
Marshal for these requirements. The resolution of these items may impact the site design
including such items as building dimensions and height, building openings, and fire
protection needs, etc.
6) The applicant shall be aware that Conditional Use Plan approval does not represent a
Building Permit and associated construction activity permits. A separate application
process is required for issuance of a Building Permit from the City of Dover. Building
Permits will be required for each building and for each tenant space fit-out/occupancy.
7) In the event that there are changes to the architecture, building footprint, layout or square
footage of the building contact the Planning Office. These changes may require review by
the Planning Commission.
8) The applicant/developer shall be aware that prior to any ground disturbing activities on
the site the appropriate Site Plan approvals, Pre-Construction meetings, site inspections
and permits are required.
9) The applicant shall be aware that Plan approval does not represent a Sign Permit, nor
does it convey permission to place any sign on the premises. Any proposed site or
building identification sign may require a Sign Permit from the City of Dover prior to
placement of any such sign in accordance with Zoning Ordinance Article 5 §4.
If you have any questions or need to discuss any of the above comments, please call the
above contact person and the Planning Department as soon as possible.
27
Página 28
Item 4.
CITY OF DOVER
DEVELOPMENT ADVISORY COMMITTEE
APPLICATION REVIEW COMMENTARY
STAFF D.A.C. MEETING DATE: DECEMBER 30, 2020
APPLICATION: Cassidy Commons at 101-1001 Cassidy Drive
FILE #: C-21-01
REVIEWING AGENCY: City of Dover Department of Public Works
CONTACT PERSON: Sharon J. Duca, P.E.
CONTACT PHONE #: 302-736-7025
THE SUBJECT PROPOSAL HAS BEEN REVIEWED FOR CODE COMPLIANCE, PLAN CONFORMITY AND COMPLETENESS IN ACCORDANCE WITH THIS AGENCY’S
AUTHORITY AND AREA OF EXPERTISE. THE FOLLOWING ITEMS HAVE BEEN IDENTIFIED AS ELEMENTS WHICH NEED TO BE ADDRESSED BY THE APPLICANT:
CITY AND STATE CODE REQUIREMENTS
STORMWATER / STREETS / SANITATION / GENERAL
1. None.
RECOMMENDATIONS SUGGESTED AS CONDITIONS OF APPROVAL TO MEET CODE OBJECTIVES
STORMWATER
1. None.
STREETS
1. None.
SANITATION
1. The City of Dover is able to provide a maximum of two (2), ninety (90) gallon trash containers to commercial
customers. Bulk and yard waste collection services are not provided. Based upon the associated use, and to most
effectively meet the sanitation needs at this location, it is strongly recommended that a private hauler be utilized to
provide trash services.
GENERAL
1. None.
ADVISORY COMMENTS TO THE APPLICANT
STORMWATER / STREETS / SANITATION / GENERAL
1. None.
IF YOU HAVE ANY QUESTIONS OR NEED TO DISCUSS ANY OF THE ABOVE COMMENTS, PLEASE CALL THE ABOVE CONTACT PERSON AND THE PLANNING
DEPARTMENT AS SOON AS POSSIBLE.
28
Página 29
Item 4.
CITY OF DOVER
DEVELOPMENT ADVISORY COMMITTEE
APPLICATION REVIEW COMMENTARY
STAFF D.A.C. MEETING DATE: DECEMBER 30, 2020
APPLICATION: Cassidy Commons at 101-1001 Cassidy Drive
FILE #: C-21-01
REVIEWING AGENCY: City of Dover Department of Water & Wastewater
CONTACT PERSON: Jason A. Lyon, P.E., Director of Water & Wastewater
CONTACT PHONE #: 302-736-7025
CONTACT PHONE #: jlyon@dover.de.us
T HE S UBJECT P ROPOSAL HAS BEEN R EVIEWED FOR C ODE C OMPLIANCE , P LAN C ONFORMITY AND C OMPLETENESS IN
A CCORDANCE WITH THIS A GENCY ’ S A UTHORITY AND A REA OF E XPERTISE .
T HE F OLLOWING I TEMS HAVE BEEN I DENTIFIED AS E LEMENTS W HICH N EED TO BE A DDRESSED BY THE A PPLICANT :
CITY AND STATE CODE REQUIREMENTS
WATER
1. All water utility components must meet the requirements of the Water Wastewater Handbook, effective date March 22, 2010.
Please contact our office for more information.
2. The following notes must be added to the plans:
a. Hydrant connections by the contractor are prohibited. This method may not be utilized during any phase of the project.
b. Any existing water lines not to be utilized by the proposed facility must be properly abandoned at the mains in accordance
with the City of Dover Department of Water & Wastewater specifications and requirements.
c. The site contractor shall contact the City of Dover Department of Water & Wastewater Construction Manager at (302) 736-
7025 prior to the start of construction. A representative from the City of Dover Department of Water & Wastewater must
observe and approve all City owned water and sanitary sewer interconnections and testing. All water taps must be
performed by a City of Dover approved contractor. The proposed location for the water connection may need to be
adjusted in the field due to conditions of the existing main. Possible conditions that would require tapping relocation
include proximity to pipe joints, other taps, concrete encasements, conflict with other utilities, and the like. Test holes
must be performed by the contractor to determine the best tapping location. The City of Dover will not be held responsible
for field conditions requiring adjustment of the tapping location or for any work required by the contractor to make an
appropriate and lawful connection.
3. The size, type, and location of all proposed and existing water lines and valves must be shown on the plan.
4. Water usage projections (peak demand or plumbing fixtures) must be submitted to our office to correctly determine the size of
the domestic and irrigation (if applicable) water meter for the proposed building. These projections must be submitted prior to
approval so the meter size can be placed on the final site plan. The proposed water meter must be installed in a pit per City of
Dover requirements and manufacturer’s recommendations. Also, a dual check valve is required downstream of the meter.
5. The domestic service, fire main connection and valves must be clearly shown for each building. A valve must be installed at the
tee to isolate combined fire and domestic water service to the building from the water loop. Typically this valve is installed at
the tee or an acceptable distance from the building. A valve must be provided on the domestic water service, which must be
tapped off of the combined eight-inch (8”) fire/domestic service outside of the building. The domestic water tap and valve
29
Página 30
Item 4.
Cassidy Commons at 101-1001 Cassidy Drive
File #: C-21-01
December 30, 2020
Page 2 of 3
should be as close to the building as possible. Typically, the domestic tap and valve are located within five feet (5’) to ten feet
(10’) of the building. A blow up detail of this layout is recommended.
6. Provide a construction detail for the proposed restraining system for the fire main located within the buildings. The Department
of Water & Wastewater will test and inspect all fire mains to a blind flange located inside the buildings. The blind flange with
tap is used for hydrostatic pressure testing (200 psi for two (2) hours) and dechlorination. The flange must be restrained in the
direction of the pipe entering the facility. A pipe entering horizontally through a wall sleeve shall be restrained with rods
through the wall. A pipe entering vertically through a slab shall be restrained through the floor to the ninety degree (90) bend
and thrust block. All rods shall be a minimum of ¾” all thread. All pipes through walls and slabs must be Class 52 cement lined
ductile iron pipe. Confirm particulars to meet this requirement with mechanical designer.
7. A minimum of fifteen feet (15’) shall be provided between the fire hydrant and fire hydrant valve.
WASTEWATER
1. All wastewater utility components must meet the requirements of the Water Wastewater Handbook, effective date March 22,
2010. Please contact our office for more information.
2. The following notes must be added to the plans:
a. Any existing sanitary sewer lines not to be utilized by the proposed facility must be properly abandoned at the mains in
accordance with the City of Dover Department of Water & Wastewater specifications and requirements.
b. Part II, Chapter 180, Article III, Section 180-10 of the Code of Kent County requires that “no person shall discharge or cause
to be discharged any stormwater, surface water, uncontaminated groundwater, roof runoff, subsurface drainage,
uncontaminated noncontact cooling water or unpolluted industrial process waters to any sanitary sewer”, this shall include
condensate. Sec. 110-231 of the City of Dover Code defines storm sewer as “…any system used for conveying rain water,
surface water, condensate, cooling water or similar liquid wastes, exclusive of sewage.” The contractor, developer, owner
and designers shall ensure during construction that no illegal discharges to the sanitary sewer system are created with the
site improvements.
3. The size, length, slope, type and flow directions must be shown on all existing and proposed sanitary sewer lines. Rim and
invert elevations must be labeled on all sanitary structures.
4. Cleanouts must be installed on sanitary sewer laterals within five feet (5’) of the building, one foot (1’) outside of the right-of-
way and at all bends. Any cleanout located within a traffic bearing location shall be installed with a heavy duty cast iron frame
and cover to prevent damage to the cleanout and lateral.
5. Sizing (flow) calculations must be submitted for all sanitary sewer laterals (other than for single-family dwellings) showing that
velocity and all other requirements are met.
6. Sizing (flow) calculations must be submitted for all sanitary sewer mains showing that velocity and all other requirements are
met. Any projected future flow requirement must be clearly identified.
7. If kitchen facilities are proposed a minimum 1,000 gallon, two chamber grease trap, meeting all Kent County ordinance
requirements, must be provided. A construction detail for the proposed grease trap, as well as the proposed location, must be
provided on the plan.
GENERAL
1. All existing utilities shall be adjusted to final grade in accordance with current City of Dover requirements and practices. This
must be included as a note on the plan.
2. No trees may be planted within ten feet (10’) of utility infrastructure.
3. The final site plan must be submitted in the following compatible digital formats:
a. AutoCAD 2018 (.dwg format).
b. Adobe Reader (.pdf format).
30
Página 31
Item 4.
Cassidy Commons at 101-1001 Cassidy Drive
File #: C-21-01
December 30, 2020
Page 3 of 3
RECOMMENDATIONS SUGGESTED AS CONDITIONS OF APPROVAL TO MEET CODE OBJECTIVES
WATER / WASTEWATER / GENERAL
1. None
ADVISORY COMMENTS TO THE APPLICANT
WATER
1. The City of Dover water system is available to this site. The developer is responsible for all costs associated with extending and
providing service to the proposed development.
2. Prior to plan approval, the water system plans must be submitted to the Division of Public Health, Office of Drinking Water for
review and approval. The owner/developer will be responsible for providing all completed forms and plan sets to the City of
Dover as required for submission to the Office of Drinking Water. Plans will not be submitted to the Office of Drinking Water
until review has been completed by our office.
3. Hydrant flow testing is currently only performed during the spring and fall. The applicant must call the Department of Water &
Wastewater directly to schedule these tests. This applies to both existing hydrants as well as those proposed for the site.
4. Water impact fees will be required to be paid prior to Certificate of Occupancy for this project.
WASTEWATER
1. The City of Dover sanitary sewer system is available to this site. The developer is responsible for all costs associated with
extending and providing service and capacity to the proposed development.
2. Prior to plan approval, it may be required to submit the sanitary sewer system plans to the DNREC, Division of Water Resources,
Surface Water Discharges Section for review and approval. The owner/developer is responsible for providing all application
fees, completed forms and plan sets directly to DNREC.
3. Profiles of the sanitary sewer main must be provided with the construction plans. All water, sanitary sewer and storm sewer
crossings must be shown on the profiles.
4. Wastewater impact fees will be required to be paid prior to Certificate of Occupancy for this project.
GENERAL
1. The applicant is advised that depending upon the size of the existing water service and sanitary sewer lateral to be abandoned,
flowable fill may be required.
2. When this project is at least seventy five percent (75%) built out, the developer can request dedication for water and
wastewater mains to be provided to the City of Dover for ownership.
3. Construction plans will not be reviewed by our office unless all previous comments have been clearly addressed within the plan
set and accordingly identified within an itemized response letter and with the Water/Wastewater Initial Plan Submission
Checklist, which can be obtained from the following website: https://imageserv9.team-
logic.com/mediaLibrary/198/WaterWastewaterHandbookFinal_1.pdf, page 88.
I F Y OU H AVE A NY Q UESTIONS OR N EED TO D ISCUSS ANY OF THE A BOVE C OMMENTS , P LEASE C ALL THE A BOVE C ONTACT P ERSON AND THE
P LANNING D EPARTMENT AS S OON AS P OSSIBLE .
31
Página 32
Item 4.
CITY OF DOVER ELECTRIC
DEVELOPMENT ADVISORY COMMITTEE
APPLICATION REVIEW COMMENTARY
STAFF D.A.C. MEETING DATE: DECEMBER 30, 2020
APPLICATION: Cassidy Commons at 101-1001 Cassidy Drive
FILE #: C-21-01
REVIEWING AGENCY: City of Dover Electric Department
CONTACT PERSON: Paul Waddell, Electric Director
CONTACT PHONE #: 302-736-7072
CONTACT EMAIL: pwaddell@dover.de.us
T HE S UBJECT P ROPOSAL HAS BEEN R EVIEWED FOR C ODE C OMPLIANCE , P LAN C ONFORMITY AND C OMPLETENESS IN A CCORDANCE
WITH THIS A GENCY ’ S A UTHORITY AND A REA OF E XPERTISE .
T HE F OLLOWING I TEMS HAVE BEEN I DENTIFIED AS E LEMENTS W HICH N EED TO BE A DDRESSED BY THE A PPLICANT :
CITY AND STATE CODE REQUIREMENTS
ELECTRIC
1. Any relocation of existing electrical equipment will be engineered by the City of Dover Electric Department. Developer
may be required to perform a quantity of the relocation. Any work performed by the City of Dover will be at the
owner’s expense.
2. Owner is responsible for locating all existing underground facilities to include electric, water and gas.
3. Owner is responsible for site and/or street lighting.
4. Must maintain 10' clearance around all electrical equipment, unless pre-approved by the City of Dover Electric
Engineering Department.
5. Prior to the completion of any/all designs and estimates, the owner is responsible for providing the Electric
Engineering Department with a physical address of the property.
6. All Engineering and design for Dover Electric will be engineered upon receipt of final approved plans. All Engineering
work will be furnished by the City’s Electric Engineering Department.
GENERAL
1. Final site plan must be submitted in a digital format compatible with AutoCAD 2010 (.dwg format) and Adobe Reader
(.pdf format), if applicable.
RECOMMENDATIONS SUGGESTED AS CONDITIONS OF APPROVAL TO MEET CODE OBJECTIVES
1. Owner must give the City of Dover Electric Department three (3) months’ notice prior to construction. Owner is
responsible for following the requirements outlined in the City of Dover’s Electric Service Handbook. The handbook
is now available on the website at the following link: https://evogov.s3.amazonaws.com/media/27/media/13108.pdf.
32
Página 33
Cassidy Commons at 101-1001 Cassidy Drive Item 4.
File #: C-21-01
December 30, 2020
Page 2 of 2
ADVISORY COMMENTS TO THE APPLICANT
1. Provide load sheets as soon as possible for proper sizing of transformers and creation of primary fee estimates.
Current load sheets can be found at the following link:
https://www.cityofdover.com/media/Electric%20Department/COD%20Electric%20Load%20Sheet.pdf.
2.
I F Y OU H AVE A NY Q UESTIONS OR N EED TO D ISCUSS ANY OF THE A BOVE C OMMENTS , P LEASE C ALL THE A BOVE C ONTACT P ERSON
AND THE P LANNING D EPARTMENT AS S OON AS P OSSIBLE .
33
Página 34
C F
C-21-01 I I
Item 4.
T R
CITY OF DOVER Y E
DEVELOPMENT ADVISORY COMMITTEE O M
F A
APPLICATION REVIEW COMMENTARY
R
D.A.C. MEETING DATE: 12/30/20 D S
O H
V A
E L
APPLICATION: Cassidy Commons at 101-1001 Cassidy Dr
R
FILE #: C-21-01 REVIEWING AGENCY: City of Dover, Office of the Fire Marshal
CONTACT PERSON: Jason Osika, Fire Marshal PHONE #: (302) 736-4457
THE SUBJECT PROPOSAL HAS BEEN REVIEWED FOR CODE COMPLIANCE, PLAN CONFORMITY, AND
COMPLETENESS IN ACCORDANCE WITH THIS AGENCY’S AUTHORITY AND AREA OF EXPERTISE.
THE FOLLOWING ITEMS HAVE BEEN IDENTIFIED AS ELEMENTS WHICH NEED TO BE ADDRESS BY THE
APPLICANT:
CITY AND STATE CODE REQUIREMENTS:
1. Proposed occupancy classification is storage/industrial.
2. Building Access shall be no further than 50 feet from a primary entrance
Where buildings are provided with an automatic sprinkler system installed in accordance with
NFPA 13, access shall be no further than 100 feet from the primary entrance.
(2015 Delaware State Fire Prevention Regulations, 705, Chapter 5, 3)
3. Parking shall be prohibited in front of the primary entrance for a width of not less than 1.5 times
the width of the door(s) or for 10 feet, whichever is greater.
(2015 Delaware State Fire Prevention Regulations, 705, Chapter 5, 6.3.2)
4. Perimeter access shall be 50% (25% if sprinklered) and clearly shown on the plans.
Perimeter Access minimum width shall be 15 feet measured from the face of the building at grade
with a maximum slope of ten percent (10%). Plantings and utility services (includes condenser
units, transformers, etc.) shall be permitted within the perimeter access, and shall not interfere
with emergency services fire ground operations.
If a physical barrier (fence, pond, steep slope, etc) prevents access, that portion of the building
perimeter shall not be included in the calculation of Percent of Perimeter Access.
(2015 Delaware State Fire Prevention Regulations, 705, Chapter 5, 3)
5. Fire lanes are shown covering approximately 40% of the proposed building.
Fire lanes are required to be 24 feet wide and run along the front of the building as determined by
the primary entrance(s). In cases where there is more than one primary entrance(s), each shall be
served by a fire lane even if this exceeds the percentage as required.
The closest edge of fire lanes shall not be located closer than ten (10) feet to the exterior wall and
the closest edge of fire lanes shall not be located further than 50 feet from the exterior wall if one
34
Página 35
Item 4.
or two stories in height; 40 feet if three or four stories in height, or 30 feet if over four stories in
height.
(2015 Delaware State Fire Prevention Regulations, 705, Chapter 5)
6. Where parking is located between the building and the fire lane, parking shall not be located
closer than 15 feet to the exterior wall.
(2015 Delaware State Fire Prevention Regulations, 705, Chapter 5, 6.4.1)
7. All Fire Lanes shall be marked as follows:
both the inner and outer edges of the fire lane shall be marked, where curbs are present, the top
and face of the curb shall be painted yellow, where no curbs are present, a four inch (4”) solid
yellow demarcation line shall mark the edge(s) of the fire lane.
(2015 Delaware State Fire Prevention Regulations, 705, Chapter 5, 7)
8. The specific color yellow shall be the uniformly accepted yellow as utilized by State of Delaware
Department of Transportation (DelDOT). Only vivid and durable paint shall be used and shall be
suitable for street surfaces
9. Fire lane signs shall be located as follows:
see Figure 5-16 – Approved Sign For Marking Fire Lanes, fire lane signs shall be spaced at 150
foot intervals maximum, all fire lane signs shall be located no less than six feet (6’) and no higher
than eight feet (8’) above the pavement, signs shall be placed at each end of the fire lane, and
signs shall face all oncoming traffic.
Where parking is not restricted roadway markings shall utilize the words "FIRE" and "LANE" in
lieu of fire lane signs and shall conform to the specifications of 7.6.
(2015 Delaware State Fire Prevention Regulations, 705, Chapter 5, 7)
10. Where overhangs, canopies, balconies, or any other building or site features must project over
any fire lane, an unobstructed vertical clearance of not less than 13’-6” above the fire lane shall be
provided and the portion of the building perimeter which contains overhangs, canopies,
balconies, or any other building features shall not apply towards the fire lane accessibility
requirements of Section 4.0, Table 5-1 in this chapter.
(2015 Delaware State Fire Prevention Regulations, 705, Chapter 5, 6.8)
11. Multiple Access Roads shall be provided when a fire department access road (fire lane) is
determined by the Fire Marshal to be impaired by vehicle congestion, condition of terrain,
climatic conditions, or other factors that could limit access such as placement of fire hose from
fire equipment.
12. Street width shall be in accordance with City of Dover Code of Ordinances, Appendix A, Article
VII, Section A. 13,
Residential areas
24 feet wide with no parking,
30 feet wide with parking on one side, or
36 feet wide with parking on both sides
Commercial areas
26 feet wide with no parking,
32 feet wide with parking on one side, or
38 feet wide with parking on both sides
35
Página 36
Item 4.
Alley
12 feet wide
Any dead-end road more than 300 feet in length shall be provided with a turnaround or cul-de-
sac as outlined in the 2015 Delaware State Fire Prevention Regulations 705, chapter 5, 2.3.
13. Speed Reduction Devices must be approved, please see City of Dover Ordinance Chapter 98-10 in
reference to this process.
14. Gated Areas: Fire Department access shall be provided to the property through the use of a
system or device approved by the Fire Marshal. The system or device required shall be located in
an area accessible to the fire department and approved by the Fire Marshal. All gates shall be
either automatic or manual.
An automated system shall consist of one manual and one automated means to open the gate.
The owner or their representative shall meet with the Fire Marshal prior to submission to agree
on the system. A letter of agreement shall be created and signed by both parties. The letter shall
include a detailed description of both the manual and automated means.
A manual gate shall consist of one manual means to open the gate. The owner or their
representative shall meet with the Fire Marshal prior to submission to agree on the means to
open. A letter of agreement shall be created and signed by both parties. The letter shall include a
detailed description of the manual means to open.
To be considered accessible for fire department apparatus the actual clear openings shall be not
less than 14 feet, the paved surface through the gate shall be not less than 12 feet, and the gate
shall be setback from the perpendicular street by at least 50 feet.
Please contact this office to discuss options available to comply with this requirement.
(2015 Delaware State Fire Prevention Regulations 705, Chapter 5, 2.6)
15. All fire hydrants shall be marked as prescribed within the appropriate section of this regulation
and as illustrated by the appropriate figures of this regulation.
All fire hydrants shall have minimum of four-inch (4") solid yellow demarcation lines to define
specific areas, where fire hydrants are located along a curb line with permitted parking, the area
between the fire hydrant and the street or fire lane shall be stenciled with four inch (4")
demarcation lines and the words "NO PARKING", demarcation lines shall be measured from the
center line of the fire hydrant and extend for a distance 15 feet on both sides.
Where fire hydrants are located in parking lots or other areas susceptible to blockage by parked
vehicles they shall be treated as follows: fire hydrants shall be protected in all directions for a
distance of seven feet (7') with barriers or curbing, Minimum four-inch (4") diameter steel
bollards filled with concrete and marked yellow shall be installed at the outermost corners of the
fire hydrant demarcation area. The minimum height of the bollard shall be 36 inches above the
finished grade of the adjacent surface, and the steamer connection of all fire hydrants shall be
positioned so as to be facing the edge of the street, or traffic lane.
(2015 Delaware State Fire Prevention Regulations, 705, Chapter 6, 2)
The owner is responsible if the hydrant is private.
16. Hydrant barrels shall be provided with reflective material, such as paint, durable for
highway/roadway markings or a reflective tape of a minimum of 2” in width around the barrel
under the top flange, hydrant bonnets shall be color coded based on the following criteria: class
AA 1500 GPM - painted light blue, class A 1,000 GPM -1499 GPM - painted green, class B 500 -
999 GPM - painted orange, class C 250 - 499 GPM - painted red, class D under 250 GPM -
painted black.
36
Página 37
Item 4.
(2015 Delaware State Fire Prevention Regulations 703, Chapter 3. 4)
The owner is responsible if the hydrant is private.
17. NFPA 72 compliant Fire Alarm System TBD per occupancy code requirements.
Fire alarm in place of assembly. Fire alarm required. Any new occupancy or new portion of an
occupancy determined to be a place of assembly by the fire marshal and is capable of receiving an
occupant load of 75 persons or greater, shall be required to install a fire alarm in accordance with
NFPA codes governing the installation of fire alarms and the National Electrical Code.
Fire alarm system required. Any existing occupancy or portion of an existing occupancy determined
to be a place of assembly by the fire marshal, and is undergoing renovations in excess of 50
percent of the assessed value of the building and is capable of receiving an occupant load 75
persons or greater or is being enlarged to receive an occupant load of 75 persons or greater, shall
be required to install a complete fire alarm system in accordance with NFPA codes governing the
installation of fire alarms and the National Electrical Code.
Public mode audible requirements. To ensure that audible public mode signals are clearly heard by
occupants of a structure, they shall have a sound level at least 15 decibels (dB) above the average
ambient sound level or five decibels (dB) above the maximum sound level having a duration of at
least 60 seconds, whichever is greater, measured five feet (1.5m) above the floor in the area
required to be served by the system using the A-weighted scale dBA. In the event the stated
requirement cannot be met a shunt trip relay/switches shall be the approved method of meeting
the intent of this section of the Code.
(City Code of Ordinances 46-171)
18. Sprinkler system TBD (researching previous requirement). Sprinkler system is shown on the site
plan. System is to be monitored by an approved Fire Alarm System.
This chapter shall apply to all buildings, structures, marine vessels, premises, and conditions
which are modified by more than 50% after the effective date of these Regulations. The 50%
figure shall be calculated utilizing the gross square footage of the building, structure, marine
vessel, premises and conditions as to arrive at the correct application.
Any proposal that is presented to the Office of the State Fire Marshal for review and approval for
a building rehabilitation as defined in the 101 Life Safety Code, for less than 50% of the gross square
footage of a non-sprinklered building, may not have another such project for the same building submitted
for review and approval any sooner than three (3) years after the date of the final inspection unless
sprinkler projection is provided throughout the entire building.
In all buildings exceeding 10,000 square feet of aggregate, gross floor area.
In all buildings in excess of 40 feet in height or more than four (4) stories in height.
In all buildings or areas thereof used for the storage, fabricating, assembling, manufacturing,
processing, display or sale of combustible goods, wares, merchandise, products, or materials when more
than two (2) stories or 25 feet in height.
In all basement areas exceeding 2,500 square feet floor area.
In residential occupancies when of: Type V (0,0,0) or Type III (2,0,0) construction and exceeding
two (2) stories or 25 feet in height. Type V (1,1,1) and Type III (2,1,1) or
Type IV (2,H,H) construction exceeding three (3) stories or 3In all residential apartment
buildings storage areas except individual unit closets that are located within individual residential living
units.
In all buildings used as health care occupancies as defined in the Life Safety Code, NFPA 101, as
adopted and/or modified by these Regulations. In all buildings or areas classified as "high hazard" under
the Life Safety Code, NFPA 101, or "extra hazard" under the Standard for the Installation of Sprinkler
Systems, NFPA 13, as adopted and/or modified by these Regulations.
37
Página 38
Item 4.
All buildings used as dormitories, in whole or in part, to house students at a public or private
school or public or private institution of higher education. (16 Del.C. Ch. 88) This applies to all such
dormitories regardless if new or existing.
(2015 State of Delaware fire Prevention Regulations, 702, Chapter 4)
Places of assembly shall be sprinklered throughout in accordance with the most recently adopted
edition of NFPA 13 when the following apply:
All new indoor places of assembly with an occupant load of 150 persons or greater.
Any interior renovations of 50 percent or more to an existing place of assembly with an occupant
load greater than 150 persons.
Any additions or increase in interior size to an existing place of assembly that would create an
occupant load of 150 persons or greater.
Places of assembly where alcohol is served for consumption on the premises shall be sprinklered
throughout in accordance with the most recently adopted edition of NFPA 13 when the following
apply:
All new indoor places of assembly with an occupant load of 100 persons or greater and where
alcohol will be served for consumption on the premises.
Any interior renovation of 50 percent or more to an existing place of assembly with an occupant
load greater than 100 persons and where alcohol will be served for consumption on the premises.
Any additions or increase in interior size to an existing place of assembly which would create an
occupant load of 100 persons or greater and where alcohol will be served for consumption on the
premises.
New educational occupancies of 5,000 square feet or greater shall be sprinklered throughout in
accordance with the most recently adopted edition of NFPA 13.
(City of Dover Code of Ordinances 46-162)
19. Fire Department Connection is to be a 5-inch stortz connection on a 30-degree elbow located
within 50 feet of main entrance. Access to the Fire Department Connection must be clear
unobstructed access as defined by the AHJ.
Fire department connections. Unless otherwise approved by the fire marshal, fire department
connections shall be on the street side of the building and shall be located and arranged so that
hose lines can be readily and conveniently attached to without interference from any nearby
obstructions as defined by the fire marshal's office. Fire department connections shall be a five-
inch Storz. Fire department connections shall be within 300 feet of an approved City of Dover
Fire Hydrant and within 50 feet of the main entrance of the structure it serves. All fire
department connections shall be not less than three feet nor more than five feet in height above
finished grade. The fire marshal shall have the authority to require more stringent
requirements when deemed necessary. (City of Dover Code of Ordinances 46-162)
20. Parking and/or obstructions shall be prohibited in front of fire department connections for a
distance measuring from the center line and extending four feet on both sides.
(2015 Delaware State Fire Prevention Regulations, 705, Chapter 5, 6.3.4)
21. Fire Department Connection to be located within 300 feet of fire hydrant, measured as hose
would come off the fire equipment.
38
Página 39
Item 4.
22. If there is any type of rack storage, the following will be required: 1) a diagram showing the
layout and type of rack system 2) a list and quantity of items being stored 3) a letter from an
authorized/licensed fire suppression contractor stating that in rack sprinklers are or are not
needed. If in rack sprinklers are not needed, a letter may be requested from an
authorized/licensed fire suppression contractor to ensure that the sprinkler system is adequate
for the storage presented.
23. All standpipe and sprinkler connections shall be marked as prescribed within the appropriate
section of this regulation and as illustrated by the appropriate figures of this regulation. All
standpipe and sprinkler connections shall have minimum of four inch (4") solid yellow
demarcation lines to define specific areas, Solid yellow demarcation lines shall be measured from
the center line of the connection and extend for a distance of four feet (4') on both sides, and
where parking is allow between the building and the street or fire lane the solid yellow
demarcation lines shall extend from the end of the sidewalk surface to the street or fire lane
(Markings shall not be required on the sidewalk surface). All fire department connections
(standpipe and sprinkler) shall have a minimum 12" x 18" sign that reads FIRE DEPT.
CONNECTION, sign lettering shall be a minimum of 3 inches (3") in height with red scotchlite
letters on white scotchlite background. The sign shall be clearly visible from the fire lane or
roadway, and signs using NFPA international symbols shall be an acceptable alternative. (2015
Delaware State Fire Prevention Regulations, 705, Chapter 6, 3)
24. The installation of natural gas and LP gas meters, regulators, valves, and LP gas bottles shall be
protected from impact damage by impact protection. Natural gas and LP gas meters, regulators,
and valves located inside structures shall have impact protection, except when located in
separate protected utility rooms.
Dimensions of bollards. Bollards shall be a minimum of six-inch diameter filled with concrete. The
bollard shall be set into the ground at a depth of at least 36 inches (three ft.) embedded in
concrete at a minimum of 18 inches surrounding the bollard. The bollards must be a least 48
inches (four ft.) in height above the finish grade elevation. Any deviation of the stated
requirements must be approved by the fire marshal and/or chief building inspector. The above
dimensions shall serve as the requirement for installation; however, the fire marshal and/or chief
building inspector shall have the authority to require more stringent dimensions to fit the needs
of devices warranting impact protection.
Color of bollards. Bollards should be of the following colors; yellow, amber or orange. All colors
shall be of fluorescent or have a reflective coating. Any deviation of the stated requirements must
be approved by the fire marshal and/chief building inspector.
(City of Dover Code of Ordinances, 46-4)
25. Every house, building or structure used or intended for use as living quarters or as a place for
conducting business, and having any wall facing or abutting any public or private street or alley,
shall have displayed on that wall, in legible, easily read characters which are of contrasting color
to the background, the proper street number for such house, building, or structure in accordance
with the following:
One-family and two-family residential structures, height, the number shall measure a minimum of four
inches in height, location, the number shall be placed on the house above or to the left or right of
the front entrance, color, the number shall be contrasting to the background color, Arabic numerals,
all numbers shall be Arabic numerals.
Multiple-family dwellings, measurements, the number shall measure a minimum of six inches when
identifying individual apartments with exterior doors, and 12 inches when identifying buildings
with apartment complexes where there are two or more buildings not assigned street addresses.
39
Página 40
Item 4.
Individual buildings with street addresses shall have numbers measuring six inches, location,
numbers shall be placed either in the center of the building or on the street end of the building so
as to be visible from either the public or private street or from the parking lot, color, numbers shall
be contrasting to the background color, Arabic numerals, all numbers used shall be Arabic
numerals.
Commercial, industrial and office buildings, height, the numbers shall measure a minimum of 12 inches in
height, location generally, numbers shall be placed either in the center of the building or on the
street end of the building so as to be visible from either the public or private street or from the
parking lot,
property line or driveway, should the building be located far enough from a public or private road so
that the numbers are not clearly visible from the street, then the street address shall also be
posted on the property at or near the property line or driveway to said building,
color; each building, numbers shall be contrasting to the background color and shall be placed on
each building in the complex,
Arabic numerals, all numbers used shall be Arabic numerals,
Shopping centers. Shopping centers consisting of two or more stores shall have a tenant or suite
number affixed to the front of the tenant space and on the outside of the rear door which
corresponds with that tenant space. Numbers shall measure six inches in height.
(City of Dover Code of Ordinances, 98-344)
26. TBD A lock box (Knox) containing any and all means necessary for fire department access shall
be provided at the following occupancies: any occupancy that contains a fire alarm signaling
system that is monitored off-site, or any occupancy that contains an automatic sprinkler system.
(2015 Delaware State Fire Prevention Regulations 705, Chapter 5, 2.4)
Secured key systems. When required; exemption. A secured key system shall be required for any new
or existing building where a fire alarm or sprinkler system is being installed. It shall be the
responsibility of the owner or occupant to keep a set of keys in the secured key box that are
current to the locks of the protected occupancy. Buildings with 24-hour staffing or guard
service shall be exempt from this subsection.
Location. The secured key system shall be located as close to the main entrance as possible.
Should the building design not allow the secured key system to be located by the main
entrance, the fire marshal and fire chief shall come to an agreement as to an alternate
location for the key box. A secured key system, once installed, shall not be obstructed from
view or obstructed by any means that would delay the fire department access to the box.
Required keys. Keys to be secured in the key box shall include keys to all points of ingress or
egress, whether on the interior or exterior of the building, and keys to locked mechanical
rooms, electrical rooms, elevator rooms, fire alarm and sprinkler controls and any area
protected by automatic fire detection. Keys to individual residential apartment units are not
required.
Ordering responsibility. It shall be the responsibility of the general contractor to order the key
box for new buildings. It shall be the responsibility of the owner or tenant to order the key
box for existing buildings.
40
Página 41
Item 4.
Installation before testing. No acceptance test for sprinklers or fire alarms shall be conducted
before the installation of a key box.
(City Code of Ordinances 46-127)
Knox Box to be mounted 6 feet above ground level
27. All required means of egress shall have an exit discharge consisting of a non-slip surface and
leading to and terminating at a public way.
28. Project to be completed per approved Site Plan.
29. Full building and fire plan review is required.
30. Separate building permits/plans submission will be required for each building and/or tenant fit
out. If the permit submission is for a “shell” a Certificate of Occupancy will not be issued.
Separate plans and permits submissions will be required for each “tenant fit out” at which time a
Certificate of Occupancy will be issued upon compliance/completion of each “tenant fit out”.
Each “shell” will require a fire permit for sprinkler and fire alarm if applicable. Those systems (for
the “shell”) must be accepted into service prior to any “tenant fit out” fire permits being issued.
31. Construction or renovations cannot be started until building plans are approved.
32. Fire alarm systems, fire suppression systems, hoods, exhaust ducts, and hood suppression
systems require a fire permit from the Fire Marshal’s Office. This work cannot be started until
the permit is approved.
33. Building cannot be occupied by the public until a Certificate of Occupancy is obtained.
ADDITIONAL / SPECIFIC REQUIREMENTS TO OBTAIN APPROVAL:
1. The proposal is for manufacturing/warehousing buildings. Any other occupancy
classification would need to be approved through a building permit or license application.
Obtaining licenses and proper occupancy classifications have been an issue in the past.
2. We will not be reviewing/accepting building plans/code information as part of this submittal,
this is for site plan process only. Currently the two submitted documents do not have the
same information on them.
3. Plans show each building is sprinklered, please confirm the same.
4. Is this going to be single completed buildings or “shells” requiring fit outs?
5. This office will need to know what is being manufactured/stored in the buildings to
determine code requirements.
6. Ensure item #’s 29 and 30 listed above are followed.
7. I researched the current buildings and found the following which will be passed onto Code
Enforcement:
a. 101: A/B Ultimate Home Services (contractor), D JW Work Zone Supplies
(merchant), E Café Wine & Spirits (distributor), F 201: Eastern Shore Coffee &
Water (distributor).
b. 201: A Hunters Flooring (no license), C Morales Screen Printing (printer), D
Children’s Families First (no license), Mark North Builders (no license, could be
under contractor)
c. 301: No licenses B Tracey Palmer Ministers, Woods Hole Group, GND Contractors
41
Página 42
Item 4.
d. 401: A-D City Electric Supply (no license), E Blue Hen TV (no license) F Nu Vision
Auto Glass (motor vehicle serviceman)
e. Anyone without a license should contact planning first to see if it is a use that is
allowed in the zone
f. All trash and debris need to be removed from the property (rear), storage trailers/pods
at the rear need to be removed (if it is against code in this area)
8. Fire Lanes need to remain clear
APPLICABLE CODES LISTED BELOW (NOT LIMITED TO):
2015 NFPA 1 Fire Code (NFPA; National Fire Protection Association)
2015 NFPA 101 Life Safety Code (NFPA; National Fire Protection Association)
2013 NFPA 72 National Fire Alarm and Signaling Code (NFPA; National Fire Protection Association)
2013 NFPA 13 Installation of Sprinkler Systems (NFPA; National Fire Protection Association)
2009 IBC (International Building Code)
Latest editions of all other NFPA Codes as defined by the Delaware State Fire Prevention Regulations
2015 Delaware State Fire Prevention Regulations
City of Dover Code of Ordinances
*If you have any questions or need to discuss any of the above comments, please call the above
contact person listed.
42
Página 43
Item 4.
CITY OF DOVER D
E
DEVELOPMENT ADVISORY COMMITTEE
L
APPLICATION REVIEW COMMENTARY D
O
T
===============================================================
APPLICATION: Cassidy Commons (101 to 1001 Cassidy Drive)
FILE#: C-21-01 REVIEWING AGENCY: DelDOT
CONTACT PERSON: Joshua Schwartz PHONE#: 302-760-2768
===============================================================
THE SUBJECT PROPOSAL HAS BEEN REVIEWED FOR CODE COMPLIANCE, PLAN CONFORMITY AND COMPLETENESS IN
ACCORDANCE WITH THIS AGENCY'S AUTHORITY AND AREA OF EXPERTISE.
THE FOLLOWING ITEMS HAVE BEEN IDENTIFIED AS ELEMENTS WHICH NEED TO BE ADDRESSED BY THE APPLICANT:
CITY & STATE CODE REQUIREMENTS:
No person, firm, corporation or the like shall construct, open, reconstruct, maintain, modify or use any
crossing or entrance onto a state-maintained highway, street or road, including any drainage modifications
leading into or carried by the highway drainage system, without first having complied with standards and
regulations adopted by the Department and having obtained a permit issued by the Department.
Please contact the Delaware Department of Transportation - Development Coordination section to begin
permit process.
RECOMMENDATIONS SUGGESTED AS CONDITIONS OF APPROVAL TO MEET CODE
OBJECTIVES:
ADVISORY COMMENTS TO THE APPLICANT:
1. Schedule a pre-submittal meeting through DelDOT Subdivisions.
2. Record Plan and Entrance Plan approval will be required.
43
Página 44
KENT CONSERVATION DISTRICT
Item 4.
1679 SOUTH DUPONT HIGHWAY • DOVER, DELAWARE 19901• (302) 608-5370 • WWW.KENTCD.ORG
CITY OF DOVER
DEVELOPMENT ADVISORY COMMITTEE
APPLICATION REVIEW COMMENTARY
JANUARY 2021
APPLICATION: Cassidy Commons at 101-1001 Cassidy Drive
FILE #: C-21-01
REVIEWING AGENCY: Kent Conservation District
CONTACT PERSON: Katherine Owens PHONE #: 302-608-5370
THE SUBJECT PROPOSAL HAS BEEN REVIEWED FOR CODE COMPLIANCE, PLAN
CONFORMITY AND COMPLETENESS IN ACCORDANCE WITH THIS AGENCY’S AUTHORITY
AND AREA OF EXPERTISE. THE FOLLOWING ITEMS HAVE BEEN IDENTIFIED AS
ELEMENTS WHICH NEED TO BE ADDRESSED BY THE APPLICANT:
Source: 2019 Delaware Sediment and Stormwater Regulations
CITY AND STATE CODE REQUIREMENTS:
Kent Conservation District has no objection to the conditional use site plan for the above referenced site.
ADVISORY COMMENTS TO THE APPLICANT:
1. The Kent Conservation District sediment and stormwater management plan approval for this site
will expire on November 8, 2022.
2. If significant changes are made to the plan, a new application and plan set are to be submitted for a
re-review and approval.
44
Página 45
Item 4.
Mark E. North
211 Waterford Drive
Middletown, Delaware19709
302-530-3620
Marknorth15@gmail.com
To:
City of Dover, Delaware January 6, 2021
Department of Planning & Inspections
P.O. Box 475 Dover, Delaware 19903
Re: Cassidy Commons at 101–1001 Cassidy Drive, C-21-01
LAND DEVELOPMENT REQUEST FOR WAIVER
Elimination of Bicycle Parking
To Whom it May Concern:
The applicant requests to eliminate the bicycle parking requirement as per the
Dover, Delaware Code of Ordinances.
It is the applicants position that Cassidy Commons, unlike a retail, educational use
or office park, is not conducive to commuting by bicycle. Individual bicycle
parking racks would not likely be convent, attractive to or utilized by a person who
is so inclined to commute by bike. A cyclist would most likely park a personal
possession such as a bicycle close to the destination, i.e. the individual tenant space.
The applicant takes the opinion that the lack of bicycle parking will in no way
discourage such commuting but rather prevent the occurrence of damage to or the
theft of the bicycle. The applicant would rather not encourage such a bicycle owner
to leave, most likely, an expensive possession unattended on site for the safety of the
commuter and their possessions.
We hope you find this waiver request consistent with the intent and purpose of the
city zoning regulations, the city land use plan, and the requirements of this article.
Respectfully submitted,
Mark North
45
Página 46
Item 4.
Mark E. North
211 Waterford Drive
Middletown, Delaware19709
302-530-3620
Marknorth15@gmail.com
To:
City of Dover, Delaware January 6, 2021
Department of Planning & Inspections
P.O. Box 475 Dover, Delaware 19903
Re: Cassidy Commons at 101–1001 Cassidy Drive, C-21-01
LAND DEVELOPMENT REQUEST FOR WAIVER
Partial Elimination of Sidewalk
To Whom it May Concern:
The applicant requests to partially eliminate the sidewalk requirement as per the
Dover, Delaware Code of Ordinances, Article II, Street Construction and Article IV
Sidewalk Construction. The particular area of interest is the west side of Cassidy
Drive.
This particular request is in conjunction with a request for an upright curb waver.
The addition of sidewalk without the upright curbing will create a walk with no
meaningful separation from the motor traffic way. The existing west pavement edge
of Cassidy Drive is not a sufficient distance from the west property line to
accommodate the sidewalk, storm water management grades and landscaping
without placing the sidewalk right adjacent to the pavement.
The storm water management practices have been designed and approved to utilize
sheet run-off of storm events over pavement edges. The storm water management
plans are currently approved utilizing this practice. Creating additional impervious
surface may also impact the original, currently approved design. In addition,
placement of upright curbing and sidewalk will alter the current sheet flow approved
design. The site has been forty percent constructed as per the previous approval and
changes to the design will have substantial effect on the functionality of the current
approved plans. There is also a substantial existing culvert and headwalls that was
constructed between building 4 and building 5 as per the approved and active storm
water management plan and previous grading plan. The addition of sidewalk to the
west side of Cassidy Drive was not considered in the design and construction of the
culvert system. Substantial changes would be necessary to accommodate the
sidewalk
46
Página 47
Item 4.
The particular existing physical conditions, shape, and topography of the specific
property involved causes an undue hardship to the applicant if the strict letter of the
code is carried out. The granting of the waiver will not be injurious to the other
adjacent property as such conditions are already existing as per previous approval.
The conditions, upon which a request for the waiver is based, are particular to the
property for which the waiver is sought and are not generally applicable to other
property and do not result from actions of the applicant.
There is existing and proposed sidewalk along the east side of Cassidy Drive that
will accommodate pedestrian traffic along the corridor.
We hope you find this waiver request consistent with the intent and purpose of the
city zoning regulations, the city land use plan, and the requirements of this article.
Respectfully submitted,
Mark North
47
Página 48
Item 4.
Mark E. North
211 Waterford Drive
Middletown, Delaware19709
302-530-3620
Marknorth15@gmail.com
To:
City of Dover, Delaware January 6, 2021
Department of Planning & Inspections
P.O. Box 475 Dover, Delaware 19903
Re: Cassidy Commons at 101–1001 Cassidy Drive, C-21-01
LAND DEVELOPMENT REQUEST FOR WAIVER
Partial Elimination of Upright Curb
To Whom it May Concern:
The applicant request to partially eliminate the upright curb requirement as per the
Dover, Delaware Code of Ordinances, Article II, Street Construction, Section 98-42
Curb and Gutter. The particular areas of interest are at the east end of the existing
and proposed parking areas and the west side of Cassidy Drive.
The storm water management practices have been designed and approved to utilize
sheet run-off of storm events over pavement edges. The storm water management
plans are currently approved utilizing this practice. The placement of upright
curbing will alter the current approved design. The site has been forty percent
constructed as per the previous approval and changes to the design will have
substantial effect on the functionality of the current approved design.
The particular existing physical conditions, shape, and topography of the specific
property involved causes an undue hardship to the applicant if the strict letter of the
code is carried out. The granting of the waiver will not be injurious to the other
adjacent property as such conditions are already existing as per previous approval.
The conditions, upon which a request for the waiver is based, are particular to the
property for which the waiver is sought and are not generally applicable to other
property and do not result from actions of the applicant.
We hope you find this waiver request consistent with the intent and purpose of the
city zoning regulations, the city land use plan, and the requirements of this article.
Respectfully submitted,
Mark North
48
Página 49
Item 4.
Mark E. North
211 Waterford Drive
Middletown, Delaware19709
302-530-3620
Marknorth15@gmail.com
To:
City of Dover, Delaware January 6, 2021
Department of Planning & Inspections
P.O. Box 475 Dover, Delaware 19903
Re: Cassidy Commons at 101–1001 Cassidy Drive, C-21-01
PERFORMANCE STANDARDS REVIEW APPLICATION
To Whom it May Concern:
The applicant submits this document to provide compliance as per the
Dover, Delaware Code of Ordinances, Article 5 Section 8.1, 8.2, 8.5 and
other referenced sections.
Article 5 §8.1 Dangerous and objectionable elements. No land or
building in any zone shall be used or occupied in any manner so as to
cause any one or more of the following conditions to exist and to be
dangerous, injurious, noxious or offensive beyond the boundaries of such
premises in such a manner or in such amount as to adversely affect the
reasonable use of the surrounding area or adjoining premises: Fire,
explosive or other hazard; noise, or vibration; smoke, dust, odor or other
form of air pollution; heat, cold, dampness or electromagnetic
disturbance; glare, liquid or solid refuse or waste; traffic congestion
causing roadways or intersections in the surrounding highway network to
fall below acceptable levels of comfort and convenience; or other
substance, condition or element (referred to hereinafter as "dangerous or
objectionable elements"), provided that any use permitted or not
expressly prohibited by this ordinance may be undertaken and maintained
if it conforms to the regulations of this section limiting dangerous and
objectionable elements at the point of the determination of their
existence.
Site Characteristics
The site is proposed to have a total of 10 individual buildings utilized primarily for
the following uses: wholesale storage and warehouses, manufacturing, and building
contractor. The design is intended to accommodate multiple small business tenants
(2,000 SF average) who are contractors or warehouse operators. The building and
parking lot plan due to structure utilization does not lend itself to outside
manufacturing, storage or staging. Tenants are leasing building space with
appropriate parking spaces. There is no additional unoccupied outside space for
other use. In summary the site is not designed for or can accommodate any outside
storage or manufacturing. All activities will be confined to building interiors.
49
Página 50
Item 4.
New Tenant Occupancy Procedure
The buildings will be constructed as shell only and an individual tenant fit-out will
require a separate permit (tenant specific). As has been the policy of the City of
Dover in the past, the permit must obtain zoning approval to be issued. The tenant
must also obtain a Dover business license in order to occupy the tenant space. New
tenants will be required by the landlord/owner to provide proof of zoning approval
and a City of Dover business license. New tenants as required by the City of Dover
Fire Marshal shall acquire a building permit for occupancy regardless the need for
any building alteration.
Each tenant occupancy permit is specific to that described tenant and will be
considered non-transferable to the next tenant.
Hazard Consideration and Avoidance
The following dangers and nuisances are to be minimized by the above noted
conditions and procedures.
• Fire and explosion hazards (activities with and storage of)
• Radioactivity or electromagnetic disturbance
• Noise (sound pressure level)
• Vibration
• Smoke
• Odors (Odorous gases or odorous matter)
• Fly ash, dust, fumes, vapors, gases and other forms of air pollution
• Glare (from lighting or high temperature processes)
• Liquid or solid wastes
• Traffic congestion (Level of Service E)
The mere nature of the site will not provide suitable conditions for any outside material
processing or manufacturing that would produce such obnoxious side effects noted above
(noise, vibration, smoke, odors, dust and multiple trucks contributing to traffic
congestion). The site will not have any un-paved, non-stabilized areas to contribute to
dust or other negative environmental impacts. Again it is emphasized that activities on
site are confined to the interior of the buildings. Permitting, as outlined above, each
tenant will screen out those who are not appropriate for the facility.
We hope you find this consistent with the intent and purpose of the city zoning
regulations, the city land use plan, and the requirements of this article.
Respectfully submitted,
Mark North
50
Página 51
Item 4.
W.F.HORN
MILTON, DELAWARE
1 302-231-2176
30866 E. SALLIE ROSS BEND
PHONE: 302-674-1620
2 3
NEW BUILDING 501 DOVER, DELAWARE
FOR CONSTRUCTION
SIGNATURE OF : PURPOSE
WILLIAM F. HORN, JR.
DATE OF SIGNATURE:
PRINTED 09/14/17
09/14/17
DATE OF REGISTRATION:
EXPIRATION : 01/31/18
COPYRIGHT C 2017 W.F.HORN ARCHITECT, INC.
DESIGNED WFH
THE PROFESSIONAL SERVICES OF THE ARCHITECT ARE
UNDERTAKEN FOR AND ARE PERFORMED IN THE DRAWN WFH
INTEREST OF CASSIDY COMMONS. NO CONTRACTUAL CHECKED WFH
OBLIGATION IS ASSUMED BY THE ARCHITECT FOR THE
BENEFIT OF ANY OTHER PERSON INVOLVED IN THE PROJ. NO. 31767
PROJECT.
SCALE AS NOTED
THE ARCHITECT WHO SEALED, SIGNED AND DATED SHEET NUMBER
4 THIS DOCUMENT HAS NOT BEEN EMPLOYED TO
FURNISH CONSTRUCTION CONTRACT ADMINISTRATION
SERVICES AS DEFINED IN 24 DEL. C. 303 (C).
51