Paj 1
CITY OF DOVER PLANNING COMMISSION
AGENDA
Monday, October 21, 2013 – 7:00 P.M.
City Hall Council Chambers
15 Loockerman Plaza, Dover, Delaware
PLEDGE OF ALLEGIANCE
ROLL CALL
APPROVAL OF AGENDA
ADOPTION OF MINUTES OF REGULAR MEETING of September 16, 2013
COMMUNICATIONS & REPORTS
1) Reminder: The next Planning Commission regular meeting is scheduled for Monday, November
18, 2013 at 7:00pm in the City Council Chambers.
2) Reminder: The next Planning Commission Quarterly Workshop is scheduled for Tuesday,
November 19, 2013 at 12:00noon in the City Hall Conference Room.
3) Update on City Council Actions
a. Proclamation of National Community Planning Month
4) Update on Planning activities
OPENING REMARKS CONCERNING DEVELOPMENT APPLICATIONS
OLD BUSINESS
1) Requests for Extensions of Planning Commission Approval: None
NEW BUSINESS
1) MI-13-10 Nottingham Meadows: Revised Active Recreation Area – Review and Acceptance
of the amount of the cash-in-lieu payment of Active Recreation Area construction for the
Nottingham Meadow Subdivision. The property is zoned R-8 (One Family Residence Zone)
and a portion is subject to SWPOZ (Source Water Protection Overlay Zone) Tier 3 –
Excellent Recharge Area. The subdivision is located on the south side of Hazlettville Road
and west of Wyoming Mill Road. The owner of record is Siobain-VI, LLC. Address:
Nottingham Subdivision. Council District 2. The Planning Commission on June 17, 2013
approved a Revised Active Recreation Plan determining that a cash-in-lieu payment was
appropriate instead of recreation area construction for this subdivision.
NEW DEVELOPMENT APPLICATIONS
1) C-13-09 Bee Hive Beauty Shop at 27 West Loockerman Street – Public Hearing and Review
of a Conditional Use Plan to allow for the establishment beauty salon within the existing
Paj 2
City of Dover Planning Commission Agenda
Public Hearing: October 21, 2013
Page 2 of 3
building at 27 West Loockerman Street. The property is zoned C-2 (Central Commercial
Zone) and subject to H (Historic District Zone). The property is located on the north of West
Loockerman Street west of South State Street. The owner is Forty S. Bradford Street, LLC
c/o Chris Raubacher. The lessee is Kathryn Lord. Address: 27 West Loockerman Street.
Tax Parcel: ED-05-077.09-02-37.00-000. Council District 2. This Application was
postponed from the September meetings due to inadequate Public Notice.
2) C-13-11 Dover Christian Church at 1738 Forrest Avenue – Public Hearing and Review of a
Conditional Use Site Plan for construction of one story 9,600 SF place of worship (church
building) and associated site improvements. The existing residence on the property is
proposed for demolition. The property is 1.5576 acres and is zoned R-10 (One Family
Residential Zone) and subject to the COZ-1 (Corridor Overlay Zone). The property is
located on the south side of Forrest Avenue and west of Dover High Drive. The owner of
record is Dover Christian Church, Inc. Address: 1738 Forrest Avenue. Tax Parcel: ED-05-
075.00-01-04.00-000. Council District 1.
3) MI-13-16 Request for Street Abandonment: Harmony Lane – Public Hearing and Review
for Recommendation to City Council of a request to abandon the improved street known as
Harmony Lane which serves the Walker Woods development. This request consists of
Harmony Lane as it runs north of Walker Road. This request was filed by Milford Housing
Development Corporation. Council District 4. This Application is associated with
Application S-13-18 Redevelopment of Walker Woods.
4) S-13-18 Redevelopment of Walker Woods: The Village of Sherwood – Public Hearing and
Site Plan Review to redevelop the property with twelve (12) two story and three story
apartment buildings (a total of 77 units in Buildings A-L) and a 3,400 SF Community
Building. The properties are zoned RG-2 (General Residence Zone). The project also
includes a Parcel Consolidation Plan. The properties known as Walker Woods Phases 1 and
2 are situated on the north side of Walker Road adjoining Harmony Lane. The owners of
record are Walker Woods Properties, LLC and Milford Housing Development Corporation.
Addresses: 1357-1383 Walker Road and multiple addresses on Harmony Lane. Tax Parcels:
multiple parcels on map ED-05-067.18-01 Council District 4. This property was rezoned
From RG-3 and ROS to RG-2 on September 9, 2013 with Application Z-13-01. This
Application is also associated with Applications MI-13-16 Request for Street Abandonment:
Harmony Lane and MI-13-17 Active Recreation Area Plan for Walker Woods. Waivers
Requested: Partial Elimination of Upright Curbing and Elimination of Rear Emergency
Access for Two and Three Story Apartments.
5) S-13-19 Woodmill Apartment Storage Buildings and Garage Building and Revised Active
Recreation Area at Woodmill Apartments – Public Hearing and Site Plan Review for the
construction of a Phase 1: 6-unit garage building at 1,632 SF, construction of Phase 2: a
storage buildings at 4,800 SF, and construction of Phase 3: a storage building at 4,000 SF for
a total of 10,432 SF. The plan also includes revisions to the Active Recreation Area. The
revisions to the Active Recreation Area include the removal of the tennis courts and the
creation of a park area with a horseshoe pit and picnic table. The property is zoned RG-2
(General Residence Zone). The property is located on the south side of Farmview Drive and
east of Mifflin Road. The owners of record are Multiresidential and Multiresidential-M,
LLC. Address: 1300 Farmview Drive. Tax Parcels: ED-05-076.10-02-07.01-000 and ED-05-
Paj 3
City of Dover Planning Commission Agenda
Public Hearing: October 21, 2013
Page 3 of 3
076.10-02-56.00-000. Council District 1. This Application partially supersedes S-13-11
Woodmill Apartment Storage Building and Revised Active Recreation Area; information on
the Revised Active Recreation Area will still be applicable to S-13-19.
6) SB-13-05 Wynsome Oaks Subdivision on White Oak Road – Public Hearing and Conceptual
Subdivision Plan Review to create twelve residential lots from an existing parcel totaling
12.73 acres +/- of land. The property is zoned R-8 (One Family Residence Zone) and
SWPOZ (Source Water Protection Overlay Zone). The property is located on the south side
of White Oak Road, southwest of Mourning Dove Lane. The owner of record is TFLD
Management, LLC. Address: White Oak Road. Tax Parcel: LC05-068.00-01-18.00-000.
Council District 3. This property was previously reviewed for subdivision as Application SB-
10-02C Wynsome Oaks Subdivision: Conceptual Plan in September 2010; however, that plan
has expired. Waivers Requested: Length of Dead End Street and Partial Elimination of
Sidewalk
7) MI-13-18 New Dover High School: Revised Parking Justification and Waiver Request for
Parking Reduction – Public Hearing and Consideration of Revised Parking Justification for
parking associated with the New Dover High School and a Waiver Request for a Reduction
in the required parking. The property is zoned R-10 (One Family Residence Zone) and
subject to the COZ-1 (Corridor Overlay Zone). The property is located on the south side of
Forrest Avenue and east of Dover High Drive. The owner of record is the Capital School
District. Address: 1650 Forrest Avenue. Tax Parcel: ED-05-076.00-02-07.00-000. The
Planning Commission conditionally approved Conditional Use Site Plan C-10-05 on
December 20, 2010 and Final Site Plan Approval was granted to S-11-18.
ADJOURN
THE AGENDA ITEMS MAY NOT BE CONSIDERED IN SEQUENCE. THIS AGENDA IS SUBJECT TO
CHANGE TO INCLUDE THE ADDITION OR THE DELETION OF ITEMS, INCLUDING EXECUTIVE
SESSIONS.
Posted Agenda: October 11, 2013 posted 1:00pm
Paj 20
City of Dover
DATA SHEET FOR CONDITIONAL USE PLAN REVIEW
DEVELOPMENT ADVISORY COMMITTEE MEETING OF October 9, 2013
PLANNING COMMISSION MEETING OF October 21, 2013
Plan Title: Bee Hive Beauty Shop
C-13-09
Plan Type: Conditional Use Plan
Property Location: North side of West Loockerman Street west of South State Street
Property Address: 27 West Loockerman Street
Tax Parcel: ED-05-077.09-02-37.00-000
Owner: Forty S. Bradford Street, LLC c/o Chris Raubacher
Lessee: Kathryn Lord
Site Area: 2,377 SF ±
Present Use: Vacant first floor tenant space/ second & third floor apartments
Proposed Use: Beauty Shop – First floor
Sewer & Water: City of Dover
Zoning Classification: C-2 (Central Commercial Zone)
H (Historic District Zone)
P. O. Box 475 Dover, DE 19903
Community Excellence Through Quality Service
Paj 21
CITY OF DOVER City of
Dover
DEVELOPMENT ADVISORY COMMITTEE Planning
Office
APPLICATION REVIEW COMMENTARY
D.A.C. MEETING DATE: October 9, 2013
APPLICATION: Bee Hive Beauty Salon at 27 West Loockerman Street
FILE #: C-13-09 REVIEWING AGENCY: City of Dover Planning
CONTACT PERSON: Tracey Harvey PHONE #: (302) 736-7196
PLAN SUMMARY:
This Conditional Use Plan Review is to permit a Beauty Salon on the first floor of the existing
building located at 27 West Loockerman Street. The property for the proposed development is
zoned C-2 (Central Commercial Zone) and is subject to the H (Historic District Zone). The
property is located on the north side of West Loockerman Street west of South State Street. The
owner of record is Forty S. Bradford Street, LLC c/o Chris Raubacher, and the lessee is Kathryn
Lord. The property address is 27 West Loockerman Street. Tax Parcel: ED-05-077.09-02-37.00-
000.
Project Site
This building was built in the 1800s as a three story commercial building. It is within the
Historic District Zone and listed in the National Register of Historic Places as a contributing
resource to the Victorian Dover Historic District (K-396.100).
th
K-396.100: 27 West Loockerman Street – Late-19 century, 3-story, 3-bay, brick
nd
commercial/residential structure; flat roof, ornate cornice; arched fenestration 2 floor level;
st
modernized 1 floor level; pen eave.
The building is within the Historic District. Any exterior changes including signage are subject
to the Architectural Review Certification process and compliance with the Design Standards and
Guidelines for the City of Dover Historic District Zone.
The building consists of three floors. The first floor of the building was most recently utilized as
a restaurant. The second and third floors of the building consist of four separate apartments that
are presently occupied. The first floor of the building is currently registered as a vacant building
under the provisions of the Vacant Building Ordinance.
Proposed Project
The application seeks to allow for the establishment of a Beauty Shop on the first floor of the
Paj 22
C-13-09 Beauty Salon at 27 W. Loockerman St.
FINAL DAC Report – October 9, 2013
Page 2
existing building. The plan indicates there will be four (4) working stations, three (3) shampoo
bowls, a nail station and a hair color room.
Due to its location, this type of land use as an Beauty Salon on the first floor requires
Conditional Use approval by the Planning Commission as noted in Article 3 §13.21 of the
Zoning Ordinance.
13.2 Conditional uses. The following uses are permitted, conditional upon the approval of the
planning commission in accordance with the procedures and subject to the general conditions set
forth in article 10, section 10.1 [1] of this ordinance and to any specified requirements set forth
below. Any of the following uses in existence at the time this ordinance [section] is adopted are
considered permitted uses, and shall not lose their status as permitted uses in their existing
locations unless the use is changed to one of the uses listed above in [sub] section 13.1 of this
ordinance [section]. Changes from one conditional use to another will require conditional use
approval.
13.21 Personal service stores, including, but not limited to, barbershops, beauty shops, tailors,
day spas, and other establishments in which the primary business is the sale of a service, rather
than a product, located on the first floor on Loockerman Street between State Street and New
Street and located within 250 feet of another personal service store.
This Conditional Use is subject to the requirements of Article 10 §1 further discussed below.
With Conditional Use applications, the Planning Commission reviews the proposed project to
determine whether or not the intended use is appropriate in type and scale for the immediate
neighborhood. The Commission must also consider whether or not the proposed use will have
an adverse impact on the future orderly development of the surrounding area. Several sections of
the Zoning Ordinance which relate to the role of the Commission in reviewing Conditional Use
applications are particularly relevant when reviewing this application:
1.1 Accessibility for emergency response. That all proposed structures, equipment or material
shall be readily accessible for fire, ambulance, police, and other emergency response;
1.2 Harmony of location, size and character. That the proposed use shall be of such location,
size and character that, in general, it will be in harmony with the appropriate and orderly
development of the zone in which it is proposed to be situated and will not be detrimental to the
orderly development of adjacent properties in accordance with the zoning classification of such
properties;
For a use seeking conditional use approval that proposes to occupy an existing structure in the
C-2 Zoning District, Article 3 §13.3 outlines the submission requirements. These requirements
include a map of the property showing existing conditions and a conceptual floor plan with the
appropriate legal data.
13.3 Submission requirements for conditional uses in the C-2 zone. The following submission
requirements shall be used in lieu of the requirements of article 10, section 1.6, in the event that
the business, office, or establishment seeking conditional use approval will be occupying an
existing structure:
(a) The applicant shall cause a site map to be prepared. The applicant shall submit 21
copies of the site map at the time of application. The site map shall conform to the
following specifications and the following elements shall be included on the site map:
Paj 23
C-13-09 Beauty Salon at 27 W. Loockerman St.
FINAL DAC Report – October 9, 2013
Page 3
1. The map shall be at least 11 [inches] by 17 inches, but not more than 24
[inches] by 36 inches, and at a scale of ten, 20, 30 or 40 feet to the inch, except
that, if the property has a maximum dimension over 900 feet, a scale of 50 feet to
the inch may be used.
2. The existing building and conditions on the lot must be depicted. It is
permissible to utilize the most recent mortgage survey of the property for this
purpose. If conditions, such as landscaping and accessory structures, on the lot
have changed since the survey was completed, the applicant shall depict these
changes on the plan to the best of his/her ability. However, the nature and extent
of such revisions must be approved by the city planner at the required pre-
application meeting.
3. A conceptual floor plan of the building is required. This floor plan must depict
the location and percent of total floor area devoted to the proposed uses. Any
uses on separate floors which are not the subject of the application must be
referenced by a note on the plan. The city planner may request more detailed
information, including architectural floor plans, on a case-by-case basis at his/her
discretion.
4. Legal data:
(a) Lot, blocks, and section number.
(b) Name and address of the owner of record.
(c) Name and address of the equitable owner, if any.
(d) Name and address of the person, firm, or organization preparing the
map.
(e) Date, north point, and written and graphical scale.
(f) The location and names of adjacent streets.
(g) The location, zoning, and owners of record of all adjacent properties.
The Bee Hive Beauty Salon was permitted to open in advance of their Conditional Use hearing,
as the tenant space they previously occupied experienced severe water damage so that it could no
longer be occupied. The Planning Staff met with the applicant and explained the requirement for
Conditional Use approval in order to operate, clarifying that if the Conditional Use Permit is not
approved, the business would be required to relocate. Opening of the business at this location in
advance of the Conditional Use hearing was permitted by the Planning Office, following an
inspection by the Chief Building Inspector and Fire Marshal, to ensure that no irreparable harm
to their business resulted from prolonged closure due to the property damage that their former
location.
SITE CONSIDERATIONS:
Trash Collection
There is not a specific Dumpster pad requirement for personal service uses. Arrangements for
trash collection will need to be made with either the City of Dover or a private trash collection
service. Dumpster enclosures are required and must be implemented where space is available on
site.
Paj 24
C-13-09 Beauty Salon at 27 W. Loockerman St.
FINAL DAC Report – October 9, 2013
Page 4
Parking
The C-2 zoning district does not have an off-street parking requirement for existing buildings.
Staff notes that there several municipal parking lots located within the immediate area and on
street parking.
Bicycle Parking
Bicycle parking is not required as there is no off-street parking requirement. There are bicycle
parking facilities along West Loockerman Street (post and loop style).
Sidewalk
There is existing sidewalk along West Loockerman Street.
THE SUBJECT PROPOSAL HAS BEEN REVIEWED FOR CODE COMPLIANCE, PLAN
CONFORMITY, AND COMPLETENESS IN ACCORDANCE WITH THIS AGENCY’S
AUTHORITY AND AREA OF EXPERTISE.
CITY AND STATE CODE REQUIREMENTS:
1) The Site Data and plan drawing column will need to be updated prior to Final Approval with
the following:
a) Any changes recommended or approvals by the Planning Commission.
b) Indicate the proposed use.
c) Indicate the amount of floor area within the building to be utilized by the tenant
d) Add legal data items :
1. Name and address of the owner of record.
2. Name and address of equitable owner, if any.
2) Provide an Owner’s Certification note and signature line to plan sheet. See text below.
OWNER’S CERTIFICATION:
I, _______________________, hereby certify that I am the owner of the property described and
shown on this plan, that the plan was made at my direction, and that I acknowledge the same to be
my act and desire the plan to be developed as shown in accordance with all applicable laws and
regulations.
DATE ___________________ SIGNATURE_____________________________
Lessee’s signature will need to be added to the plan sheet.
3) Clarify any existing parking spaces that are available on this parcel at the rear of the
property.
RECOMMENDATIONS SUGGESTED AS CONDITIONS OF APPROVAL TO MEET CODE
OBJECTIVES:
1. Install a bicycle parking rack in the rear parking lot to serve this facility. This will allow
the street side bicycle parking racks to be utilized by customers.
Paj 25
C-13-09 Beauty Salon at 27 W. Loockerman St.
FINAL DAC Report – October 9, 2013
Page 5
ADVISORY COMMENTS TO THE APPLICANT:
1) The ability of the business to remain at this location is dependent upon approval of the
Conditional Use Permit application. The Planning Office issued temporary approval for
the business to open in the interim, as water damage made the previous business location
unable to be occupied.
2) Following Planning Commission approval of the Conditional Use Plan, the Plan must be
revised to meet all conditions of approval from the Development Advisory Committee or
as otherwise noted. A Check Print must be submitted for review by Planning Office Staff.
Upon determination that the Plan is complete and all agency approvals have been
received, copies of the Plan may be submitted for final endorsement.
3) It appears that this new use will involve a change of occupancy classification with
implications for compliance with Building Codes and Fire Codes. The applicant is
advised to meet with the City’s Fire Marshall and Building Inspector.
4) The applicant shall be aware that the Conditional Use Plan approval does not represent a
Sign Permit, nor does it convey permission to place any sign on the premises. Any
proposed site or building identification sign shall require a Sign Permit from the City of
Dover prior to placement of any such sign. A Sign Permit # 13-1077 was issued for the
installation of a wall sign.
5) The applicant shall be aware that the Conditional Use Plan approval does not represent a
Building Permit and associated construction activity permits. A separate application
process is required for issuance of a Building Permit and Certificate of Occupancy from
the City of Dover.
6) Exterior renovations to the building are subject to Architectural Review Certification as
the property is located within the Historic District. This may include review by the
Historic District Commission.
If you have any questions or need to discuss any of the above comments, please call the
above contact person and the Planning Department as soon as possible.
Paj 26
CITY OF DOVER
DEVELOPMENT ADVISORY COMMITTEE
APPLICATION REVIEW COMMENTARY
STAFF D.A.C. MEETING DATE: AUGUST 28, 2013
APPLICATION: BEE HIVE BEAUTY SHOP AT 27 W. LOOCKERMAN
ST.
FILE #: C-13-09
REVIEWING AGENCY: City of Dover Electric and Public Works Departments
CONTACT PERSON: Steve Enss - Electric
Jason A. Lyon, P.E. – Public Works
CONTACT PHONE #: ELECTRIC - 302-736-7070 PUBLIC WORKS – 302-736-7025
T HE S UBJECT P ROPOSAL HAS BEEN R EVIEWED FOR C ODE C OMPLIANCE , P LAN C ONFORMITY AND C OMPLETENESS IN
A CCORDANCE WITH THIS A GENCY ’ S A UTHORITY AND A REA OF E XPERTISE .
T HE F OLLOWING I TEMS HAVE BEEN I DENTIFIED AS E LEMENTS W HICH N EED TO BE A DDRESSED BY THE A PPLICANT :
CITY AND STATE CODE REQUIREMENTS
ELECTRIC
1. Owner is responsible for following the requirements outlined in the City of Dover’s Electric Service Handbook. The
handbook is now available on the website at the following link: http://www.cityofdover.com/Public-Documents-4017/.
WATER
1. Our office has no objection to the conditional use proposed for the subject property.
2. All water utility components must meet the requirements of the Water Wastewater Handbook, effective date March 22,
2010. Please contact our office for more information.
3. Due to the fact that this property is changing uses, water usage projections (peak demand or plumbing fixtures) must
be submitted to our office to correctly determine if the size of the existing domestic and irrigation (if applicable) water
meter for the building is sufficient. These projections must be submitted prior to approval so the meter size can be
placed on the final site plan. If the meter needs to be changed, a waiver letter must be submitted to the Department
of Public Works requesting a relaxation of the requirement that all water meters must be installed in a pit.
WASTEWATER
1. Our office has no objection to the conditional use proposed for the subject property.
2. All wastewater utility components must meet the requirements of the Water Wastewater Handbook, effective date
March 22, 2010. Please contact our office for more information.
3. Sizing (flow) calculations must be submitted for all sanitary sewer laterals (other than for single-family dwellings)
showing that velocity and all other requirements are met, to correctly determine if the size of the existing sanitary
sewer lateral for the building sufficient. All proposed wastewater utility components must meet the requirements of
the Water / Wastewater Handbook, effective date March 22, 2010. Please contact our office for more information.
STORMWATER / SANITATION / STREETS / GROUNDS
1. None
Paj 27
Bee Hive Beauty Shop
File #: C-13-09
August 28, 2013
Page 2 of 2
GENERAL
1. The final site plan must be submitted in a digital format compatible with AutoCAD 2010 (.dwg format) and Adobe
Reader (.pdf format).
RECOMMENDATIONS SUGGESTED AS CONDITIONS OF APPROVAL TO MEET CODE OBJECTIVES
ELECTRIC
1. None
WATER / WASTEWATER / STORMWATER / STREETS / GROUNDS / GENERAL
1. None
SANITATION
1. The City of Dover will continue to provide the current level of trash service to 27 West Loockerman Street. If
additional trash service is required, the owner shall secure a private company to take over the sanitation service.
ADVISORY COMMENTS TO THE APPLICANT
ELECTRIC
1. None
WATER / WASTEWATER / STORMWATER / SANITATION / STREETS / GROUNDS / GENERAL
1. None
GENERAL
1. Construction plans will not be reviewed by our office unless all previous comments have been clearly addressed
within the plan set and accordingly identified within an itemized response letter and with the Water/Wastewater Initial
Plan Submission Checklist, which can be obtained from the following website: https://imageserv9.team-
logic.com/mediaLibrary/198/WaterWastewaterHandbookFinal_1.pdf, page 88.
I F Y OU H AVE A NY Q UESTIONS OR N EED TO D ISCUSS ANY OF THE A BOVE C OMMENTS , P LEASE C ALL THE A BOVE
C ONTACT P ERSON AND THE P LANNING D EPARTMENT AS S OON AS P OSSIBLE .
Paj 28
C F
I I
CITY OF DOVER T R
Y E
DEVELOPMENT ADVISORY COMMITTEE
O M
APPLICATION REVIEW COMMENTARY F A
R
D.A.C. MEETING DATE: D S
O H
V A
E L
R
APPLICATION: Bee Hive Beauty Shop at 27 W. Loockerman St.
FILE #: C-13-09 REVIEWING AGENCY: City of Dover, Office of the Fire Marshal
CONTACT PERSON: Jason Osika, Deputy Fire Marshal PHONE #: (302) 736-4457
THE SUBJECT PROPOSAL HAS BEEN REVIEWED FOR CODE COMPLIANCE, PLAN CONFORMITY,
AND COMPLETENESS IN ACCORDANCE WITH THIS AGENCY’S AUTHORITY AND AREA OF
EXPERTISE.
THE FOLLOWING ITEMS HAVE BEEN IDENTIFIED AS ELEMENTS WHICH NEED TO BE ADDRESS BY
THE APPLICANT:
CITY AND STATE CODE REQUIREMENTS:
Proposed building is mercantile. The Fire Marshal has already reviewed the business and at the
time of inspection the location met all of the requirements of the Office of the Fire Marshal and
was ready for business occupancy. The current business has already moved in under those
conditions due to severe water damage at their prior location.
RECOMMENDATIONS SUGGESTED AS CONDITIONS OF APPROVAL TO MEET CODE
OBJECTIVES:
ADVISORY COMMENTS TO THE APPLICANT:
After any application has been approved by the Planning Commission, the applicant has a
maximum of thirty (30) days to appeal to the Code Board of Appeals Committee.
All comments from this office, approved by the Planning Commission are at the expense of the
owner/applicant.
The proposed building will be reviewed under Business Occupancy.
The City of Dover uses the 2012 NFPA Life Safety Code, 2009 IBC, latest editions of all other
NFPA Codes and the 2012 Delaware State Fire Prevention Regulations.
Paj 29
The Dover Fire Department request that a 8 ½ X 11 copy of the floor plan and site plan be
submitted to Station 1, attention Fire Chief, prior to the Certificate of Occupancy being issued.
If you have any questions or need to discuss any of the above comments, please call the
above contact person and the Planning Department as soon as possible.
Paj 30
CITY OF DOVER D
E
DEVELOPMENT ADVISORY COMMITTEE
L
APPLICATION REVIEW COMMENTARY D
O
D.A.C. MEETING DATE: August 28, 2013 T
===============================================================
APPLICATION: Bee Hive Beauty Shop at 27 West Loockerman Street
FILE#: C-13-09 REVIEWING AGENCY: DelDOT
CONTACT PERSON: Julio F. Seneus PHONE#: 760-2145
===============================================================
THE SUBJECT PROPOSAL HAS BEEN REVIEWED FOR CODE COMPLIANCE, PLAN CONFORMITY AND COMPLETENESS IN
ACCORDANCE WITH THIS AGENCY'S AUTHORITY AND AREA OF EXPERTISE.
THE FOLLOWING ITEMS HAVE BEEN IDENTIFIED AS ELEMENTS WHICH NEED TO BE ADDRESSED BY THE APPLICANT:
CITY & STATE CODE REQUIREMENTS:
1. The Department has no comments.
RECOMMENDATIONS SUGGESTED AS CONDITIONS OF APPROVAL TO MEET CODE
OBJECTIVES:
ADVISORY COMMENTS TO THE APPLICANT:
If you have any questions or need to discuss any of the above comments, please call the
above contact person and the planning department as soon as possible.
Paj 31
C F
I I
CITY OF DOVER T R
Y E
DEVELOPMENT ADVISORY COMMITTEE
O M
APPLICATION REVIEW COMMENTARY F A
R
D.A.C. MEETING DATE: D S
O H
V A
E L
R
APPLICATION: Bee Hive Beauty Shop at 27 W. Loockerman St.
FILE #: C-13-09 REVIEWING AGENCY: City of Dover, Office of the Fire Marshal
CONTACT PERSON: Jason Osika, Deputy Fire Marshal PHONE #: (302) 736-4457
THE SUBJECT PROPOSAL HAS BEEN REVIEWED FOR CODE COMPLIANCE, PLAN CONFORMITY,
AND COMPLETENESS IN ACCORDANCE WITH THIS AGENCY’S AUTHORITY AND AREA OF
EXPERTISE.
THE FOLLOWING ITEMS HAVE BEEN IDENTIFIED AS ELEMENTS WHICH NEED TO BE ADDRESS BY
THE APPLICANT:
CITY AND STATE CODE REQUIREMENTS:
Proposed building is mercantile. The Fire Marshal has already reviewed the business and at the
time of inspection the location met all of the requirements of the Office of the Fire Marshal and
was ready for business occupancy. The current business has already moved in under those
conditions due to severe water damage at their prior location.
RECOMMENDATIONS SUGGESTED AS CONDITIONS OF APPROVAL TO MEET CODE
OBJECTIVES:
ADVISORY COMMENTS TO THE APPLICANT:
After any application has been approved by the Planning Commission, the applicant has a
maximum of thirty (30) days to appeal to the Code Board of Appeals Committee.
All comments from this office, approved by the Planning Commission are at the expense of the
owner/applicant.
The proposed building will be reviewed under Business Occupancy.
The City of Dover uses the 2012 NFPA Life Safety Code, 2009 IBC, latest editions of all other
NFPA Codes and the 2012 Delaware State Fire Prevention Regulations.
Paj 32
The Dover Fire Department request that a 8 ½ X 11 copy of the floor plan and site plan be
submitted to Station 1, attention Fire Chief, prior to the Certificate of Occupancy being issued.
If you have any questions or need to discuss any of the above comments, please call the
above contact person and the Planning Department as soon as possible.
Paj 33
City of Dover
DATA SHEET FOR CONDITIONAL USE SITE PLAN REVIEW
DEVELOPMENT ADVISORY COMMITTEE MEETING OF October 9, 2013
PLANNING COMMISSION MEETING OF October 21, 2013
Plan Title: Dover Christian Church
C-13-11
Plan Type: Conditional Use Site Plan
Property Addresses: 1738 Forrest Avenue, Dover
Location: South side of Forrest Avenue (Route 8) and west of Dover High
Drive
Tax Parcels: ED-05-075.00-01-04.00-000
Owner: Dover Christian Church Inc.
Site Area: 1.5576 +/- acres (67,850 SF)
Present Use: Residential Dwelling (to be demolished)
Proposed Use: Place of Worship (Church)
Sewer & Water: City of Dover
Zoning Classification: R-10 (One Family Residence Zone)
COZ-1 (Corridor Overlay Zone)
P. O. Box 475 Dover, DE 19903
Community Excellence Through Quality Service
Paj 34
C P
I L
CITY OF DOVER T A
Y N
DEVELOPMENT ADVISORY COMMITTEE N
O I
APPLICATION REVIEW COMMENTARY F N
G
D.A.C. MEETING DATE: October 9, 2013 D
O
V
APPLICATION: Dover Christian Church at 1738 Forrest Avenue E
R
FILE#: C-13-11 REVIEWING AGENCY: City of Dover Planning
CONTACT PERSON: Dawn E. Melson-Williams, AICP PHONE#: 736-7196
PLAN SUMMARY:
This Plan is for review of a Conditional Use Site Plan to permit the construction of a one story
9,600 SF place of worship (church building) and other associated site improvements. The
existing residence on the property is proposed for demolition. The property is 1.5575 acres and is
zoned R-10 (One Family Residence Zone) and is subject to the COZ-1 (Corridor Overlay Zone).
The subject property is located on the south side of Forrest Avenue (DE Route 8) and west of
Dover High Drive. The owner of record is Dover Christian Church, Inc. Property Address:
1738 Forrest Avenue. Tax Parcel: ED-05-075.00-01-03.00-000. Council District 1.
Existing Property and Surrounding Area:
The property was annexed into the City in early 2007. (AX-06-09) At the time of annexation the
property was zoned to R-10 (One Family Residence Zone) and COZ-1 (Corridor Overlay Zone).
The subject property is located in the western edge of the City of Dover. Located to the north
across Forrest Avenue (Route 8) are a series of lots with single family homes which are outside
City limits and under the jurisdiction of Kent County. Also to the north across Route 8 but within
City limits is an Agricultural Preservation District with a State agricultural easement (Purchase
of Development Rights). To the east is property owned by the Capital School District which is
being developed as the New Dover High School (C-10-05/S-11-18). Adjoining this church site
to the west and south, there is a proposed multi-family development for 240 apartment units
known as Leander Lakes. Leander Lakes (S-12-18) was conditionally approved by the Planning
Commission on October 15, 2012 (previously reviewed as Application S-09-13. The Leander
Lakes application is in the Check Print review process with the reviewing agencies to obtain
final plan approval including entrance plan design review with DelDOT regarding the design of
the southern segment of Dover High Drive and connection to Tribbitt Street. The design and
construction of Dover High Drive is a joint effort of the Capital School District as associated
with the High School project and Leander Lakes.
CONDITIONAL USE
Within the R-10 zoning district, the use of a property as a site for a place of worship (church) is
permitted subject to approval of a Conditional Use by the Planning Commission. Zoning
Paj 35
C-13-11 Dover Christian Church: Conditional Use Site Plan
DAC Report of October 9, 2013
Page 3
Ordinance, Article 3 Section 1.14a gives specific conditions for property size, setbacks, lot
coverage and percentage for buildings.
With Conditional Use Applications, the Planning Commission reviews the proposed project to
determine whether or not the intended use is appropriate in type and scale for the immediate
neighborhood. The Commission must also consider whether or not the proposed use will have
an adverse impact on the future orderly development of the surrounding area. The following are
sections of the Zoning Ordinance which relate to the role of the Commission in reviewing
Conditional Use applications:
Article 10. Planning Commission
Section 1. Approval of conditional uses.
On application and after public notice and hearing, the commission may authorize the
issuance by the city planner of permits for any of the conditional uses for which this ordinance
requires, in the district in which such use is proposed to be located. In approving any such use,
the planning commission shall take into consideration the public health, safety and welfare, the
comfort and convenience of the public in general and of the residents of the immediate
neighborhood in particular, and may prescribe appropriate conditions and safeguards as may be
required in order that the results of its action may, to the maximum extent possible, further the
expressed intent of this ordinance and the accomplishment of the following objectives in
particular:
1.1 Accessibility for emergency response. That all proposed structures, equipment or
material shall be readily accessible for fire, ambulance, police, and other emergency
response;
1.2 Harmony of location, size and character. That the proposed use shall be of such
location, size and character that, in general, it will be in harmony with the appropriate and
orderly development of the zone in which it is proposed to be situated and will not be
detrimental to the orderly development of adjacent properties in accordance with the
zoning classification of such properties;
1.3 Residential zones. That, in addition to the above, in the case of any use located in,
or adjacent to, a residential zone:
1.31 The location and size of such use, the nature and intensity of operations
involved in or conducted in connection therewith, its site layout and its relation to
access streets shall be such that both pedestrian and vehicular traffic to and from
the use and the assembly of persons in connection therewith will not be
hazardous or inconvenient to, or incongruous with, the said residential district or
conflict with the normal traffic of the neighborhood; and
1.32 The location and height of buildings, the location, nature and height of
walls and fences, the nature and extent of landscaping, and other improvements
on the site shall be such that the use will not hinder or discourage the appropriate
development and use of adjacent land and buildings.
The Planning Commission may set conditions of approval for the Conditional Use during the
review process. They also have the ability to require periodic renewal of a Conditional Use
Permit and also can consider revocation of a Conditional Use Permit.
PROJECT SUMMARY
The proposed project is for demolition of the existing residential dwelling on the property and
then construction of a 9,600 SF church building. The one story building sits parallel to Forrest
Avenue with parking located on the west and south sides of the building. This (rear) parking lot
is proposed to be accessed from Dover High Drive.
Paj 36
C-13-11 Dover Christian Church: Conditional Use Site Plan
DAC Report of October 9, 2013
Page 4
COZ-1: Corridor Overlay Zone
The subject site involved with this application is located within the COZ-1 (Corridor Overlay
Zone). The Zoning Ordinance details the requirements of the COZ-1 in Article 3 §26 and its
subsections. The Corridor Overlay Zone as a planning and growth management tool is designed
to foster and attractive, efficient, and economically vibrant urban corridor along Route 8/Forrest
Avenue and Saulsbury/McKee Roads. To this end, more stringent standards are applied to
development taking place in the corridor. A discussion of the provisions of the COZ-1 which
apply to this application follows below.
The plan as presented is in compliance with the requirements listed below.
The COZ-1 does not specify a required front yard setback for non-residential properties
in this segment of the corridor; therefore, the setbacks prescribed in the Article 3 Section
1 are applied.
The building must sit parallel to the road with the longest side facing the road; the design
achieves this concept.
Achieves the following for the parking lot layout/arrangement: parking lot location no
closer to the street than the building and also not in the front yard setback, the number of
spaces versus islands (10 feet width) and median placements, and the sizing thereof.
A landscaped buffer (varying width) and sidewalk at a width 6.75 feet combines to meet
the minimum total of 12 feet that is required between the building and parking/drive
aisles.
Building complies with the allowable number of stories in the COZ-1; however,
compliance with the maximum height of 35 feet is unclear due to the presence of a
steeple on the church building.
The proposal meets the requirement that 25% of the lot consist of landscaped open space.
As shown 37.1% of the lot is open space.
Street frontages (Forrest Avenue frontage) are required to have a landscaped open space
of 25 feet and provide one tree per 50 (fifty) feet of frontage. (See Landscape discussion)
Non-frontages (side and rear yards) are required to have landscaped open space of 15 feet
when adjacent to residential uses and landscaped open space of 5 feet when adjacent to
non-residential uses and to provide one tree per 75 (seventy-five) feet.
The building shall have a corridor elevation with specific architectural features (See
Building Architecture discussion).
BUILDING ARCHITECTURE (Drawings dated 9/6/2013)
The Plan submission includes the requisite Architectural Elevation drawings presenting all
elevations of the church building. See attached elevation color renderings and site plan drawings
for detailed information on building dimensions, locations, and material choices.
The exterior finish materials for the church utilize two different colors of split face masonry and
metal siding for the walls and a metal roof system for the pitched hipped roofs. Other exterior
finish details in the form of banding, windows, trimwork of openings include the use of ground
face masonry and translucent panels. Main entrances to the building are located on the north
elevation and south elevation. These entrances highlighted by a glass and aluminum storefront
window/door systems and a metal canopy. A series of tall arched windows are used in the
sanctuary section (west end) of the building and on east elevation of the building with aluminum
storefront window systems utilized on the east section of the building and on the south elevation.
Paj 37
C-13-11 Dover Christian Church: Conditional Use Site Plan
DAC Report of October 9, 2013
Page 5
The roof is metal gable roof on two sections of the building with flat roof systems used in other
areas. A cupola with steeple is centered at the main entrance section of the building. No
information is provided on the height of this element. The applicant is still considering the
concept and design of a steeple element.
This building is subject to the Architectural Review requirements found in Article 3 §27.69 for
properties located within the Corridor Overlay Zone. See text below.
27.69 Architectural Review. The side of any building which faces the corridor (or corridors) shall
be referred to as the "corridor elevation." Buildings in the COZ-1 shall be designed to front on the
corridor, and the corridor elevation shall contain architectural elements traditionally associated
with the front of a building. Blank walls without functioning windows are prohibited along the
corridor. Windows must be incorporated into the overall design concept of the corridor elevation.
Providing one or several small windows on a large corridor elevation shall not constitute
compliance with this ordinance.
A “functioning window” shall be defined as a window which lets light into the interior of the
structure, and is integrated and related to the interior layout of the space. In addition to
functioning windows, the corridor elevation shall have the following elements:
a) A primary entrance door or doors (except for loading doors).
b) A primary entrance feature, such as a porch, portico, awning, entrance walk, or other similar
feature.
In addition, the corridor elevation shall have one of the following elements:
a) Landscaping integrated into the building design concept.
b) Architectural or urban design elements which link adjacent structures together, such as
plazas, walkways, colonnades, or similar features.
c) Architectural relief, such as vertical and horizontal off-sets in exterior wall elevations, band
courses, lintels and sill courses, cornices and the like to create shadow lines.
As currently proposed, the corridor elevation of this building includes a series of windows which
qualify as functioning windows. With the architectural elevations showing a set of main entrance
doors and primary entrance feature of a canopy on the corridor elevation, this project is in
compliance with the code requirement. The plan as submitted complies with the second
requirement of the corridor elevation (items a and c) by providing tree and shrub plantings
immediately adjacent to the front of the building and also providing a variety of architectural
relief on the corridor façade (material changes, window detailing, appearance of multiple
sections, etc.).
PARKING SUMMARY
The parking requirement for a place of worship is based on a rate one parking space per 200
square feet of floor area but not less than one space for each four (4) seats. Based on floor area
the facility would require forty-eight (48) parking spaces; however, the parking calculation based
on seating will govern. From the initial seat counts of 260, the overall parking required for the
site is sixty-five (65) parking spaces. The plan appears to shows a total of sixty-seven (67)
parking spaces including handicapped accessible spaces. A loading space is not required.
Bicycle Parking
The minimum bicycle parking is one (1) bike space for every twenty (20) parking spaces. Based
on the number of parking spaces at 65, a minimum of four (4) bicycle parking spaces are
Paj 38
C-13-11 Dover Christian Church: Conditional Use Site Plan
DAC Report of October 9, 2013
Page 6
required. The Plan indicates the location of bicycle parking racks near the building’s south
entry.
SITE CONSIDERATIONS
Building placement requirements of the Corridor Overlay Zone are found in Article 3 §27.52. It
includes the requirement that the building be placed with the long side to the roadway. This site
design places the long side parallel to Forrest Avenue.
Entrances
The site is accessed from Dover High Drive. This requires the crossing of two adjacent
properties: lands of the Capital School District and Lands of Leander Lakes, LLC. No access
from Forrest Avenue (Route 8) is shown and the existing driveway curb cut serving the existing
dwelling is to be removed.
Delaware 8 Concept Plan and Operations Study
In 2007, the Dover/Kent County Metropolitan Planning Organization developed and approved
the Delaware 8 Concept Plan and Operations Study to identify circulation improvements along
the Route 8 corridor on the west side of Dover, from the railroad tracks to Artis Drive. The
study identifies a number of north/south connector roads to relieve traffic conditions along the
Route 8 corridor. An initial segment of one of these connector roads is Dover High Drive which
this church project proposes to access from. The first segment of Dover High Drive has been
constructed.
Sidewalks
The site shows a multi-use path along the street frontage of Forrest Avenue/Route 8.
Additionally, a sidewalk is shown on one side connecting into the site along its entrance drive
from Dover High Drive. The plan seems to provide for handicapped accessible ramps at the
points of intersection.
Other Site Elements
Dumpsters are required for institutional uses at a rate of one per 40,000 SF of gross building area
and one for each additional 40,000 SF of building area. For this site it requires one Dumpster
based on the total square footage of 9,600 S.F. A masonry Dumpster enclosure with screening
plantings is shown in the southwest corner of the parking lot.
Lighting
The location of the lighting is proposed in the form of light poles around the perimeter of the
parking lot. The church facility would be considered a commercial-like use, thus requiring a
minimum of 1.5 foot candles at grade. The proposed lighting must be adequate to safely light all
parking and pedestrian areas yet must be shielded and directed as to not create a nuisance on the
adjacent properties.
TREE PLANTING AND LANDSCAPE PLAN
The tree density requirement is calculated at rate of one tree per 3000 S.F. of total site area.
Based on the 1.5576 acre (67,850 S.F.) site area, a total of twenty-three (23) trees would be
required. A total of thirty-one (31) trees are proposed. The proposed tree plantings are a mix of
deciduous and ornamental trees with groupings placed along the property frontages, in the
Paj 39
C-13-11 Dover Christian Church: Conditional Use Site Plan
DAC Report of October 9, 2013
Page 7
parking lot islands, and near the building. These tree planting locations should maintain
appropriate separation distances from utilities lines, buildings, and other site improvements.
COZ-1 Landscaping Requirements
The COZ-1 requires that a minimum of 25% of the site be landscaped open space. For this site
approximately 37.1% is open space. Trees are utilized for the landscaping within the parking lot
islands. Article 3 §27.53 C requires a landscaped buffer area of twelve (12) feet in width between
the building and the parking lot or drive areas inclusive of a minimum six (6) foot wide
sidewalk; this is shown on the Plan for the west and south sides of the church building.
The COZ-1 (Corridor Overlay Zone –1) also includes specific tree planting requirements along
property lines. One tree per fifty feet of frontage is required. A series of Red Maples, Crabapples,
and Cryptomeria trees are shown along the frontage of Forrest Avenue. One tree per 75 feet is
required on the non-frontage perimeters within the COZ-1. Tree plantings in these areas include
Red Maples, Willow Oaks, and Green Vase Zelkovas.
THE SUBJECT PROPOSAL HAS BEEN REVIEWED FOR CODE COMPLIANCE, PLAN
CONFORMITY, AND COMPLETENESS IN ACCORDANCE WITH THIS AGENCY’S
AUTHORITY AND AREA OF EXPERTISE.
CITY AND STATE CODE REQUIREMENTS:
1) The Final Plan set must include notes indicating the action taken by the Planning
Commission in regards to any waivers and listing any additional conditions of approval. The
plan set is be revised to reflect all changes recommended by the Planning Commission.
2) The actual building heights (to eave, to roof ridge, steeple, etc.) must be provided in order to
confirm compliance with the maximum building height. It appears that the steeple element
may exceed the maximum height limit for the zoning district which is 35 feet. Should the
applicant wish to include a steeple a Board of Adjustment application may be necessary. The
applicant has noted that they are considering the concept and design for a cupola and/or
steeple element at this time and understand the requirement for compliance with the height
limitations.
3) Documentation from the adjacent property owners regarding the proposed permanent cross
access easement is required. A Record Plan sheet may also be required to document this
information and the property’s access to Dover High Drive as part of the Entrance Plan
approval from DelDOT.
a) It appears that revisions to the Landscape Plans and other construction plans for the
Dover High School project and the pending Leander Lakes Apartment project will need
to be made to accommodate this proposed site entrance design. There are a number of
tree plantings proposed in this area of the adjoining properties.
b) Ensure stormwater management and drainage systems continue to function and /or are
designed to accommodate this site entrance.
4) Coordination efforts regarding the provision of water and sanitary sewer services to this
church property as routed from the proposed Leander Lakes project must continue. The
Planning Commission in its conditional approval of Application S-12-18 Leander Lakes
Paj 40
C-13-11 Dover Christian Church: Conditional Use Site Plan
DAC Report of October 9, 2013
Page 8
Apartments noted the requirement for Leander Lakes’ coordination with adjacent properties
for such services due to the regional design approach to the water and sanitary sewer system.
5) Sheet C-001:
a) Correct COZ listing to be COZ-1.
b) In Item #9, list that maximum lot coverage allowed is 75%.
c) In Item #10, correct the side and rear setbacks to be 25 feet in the R-10 as required for
this conditional use. There are no side and rear setback requirements in the COZ-1.
d) Clarify the height of the building and how measured (mean of eave and ridge or to top of
steeple).
e) Update references in General Notes to Public Works from Public Utilities. Update
references to DNREC that should be the Kent Conservation District.
f) Check spelling in General Note #24.
g) Add location of permanent easement along Forrest Avenue frontage.
h) Add notes outlining any conditions of the Planning Commission approval.
6) Clarify the address of the property. The City records indicate the address as 1738 Forrest
Avenue (not 2055 Forrest Avenue which is shown in County records). Consult with the City
of Dover Tax Assessment Office to clarify address. Update all plan sheets.
7) Sheet C-101:
a) Evaluate if existing tree can remain.
b) A Demolition Permit will be required for the demolition of the existing dwelling. The
existing utilities services must be appropriately abandoned this includes any wells, septic
systems, etc. on the site.
8) Ensure handicapped access ramps are shown at the required points of intersection of streets,
parking lot entrances, intersections of sidewalks with parking lot drive aisles, etc. Check
detail of ramp at entrance from Dover High Drive.
9) Provide construction details for the following items but not limited to: barrier free sidewalk,
curbing, traffic control signage, paving section, lighting fixtures, handicap signage, bike rack,
Dumpster, etc. in the Site Plan
10) Provide a Signage and Striping Plan or provide that information on a Plan Sheet. This
includes location of stop signs, location of stop bars, crosswalks, directional arrows, fire lane
markings, etc.
11) As plan evolves plan for the location of future site signage in compliance with the code
requirements. Consider the location of landscaping and tree planting to ensure intended
visibility of the signage. Currently the monument sign along Forrest Avenue may be located
within the permanent easement for the multi-modal path.
12) Landscape Plan, L-101:
a) Correct zoning listing of COZ to read as COZ-1.
b) Any revisions to the tree plantings must be approved by the Planning Office. Update
General Note #19.
Paj 41
C-13-11 Dover Christian Church: Conditional Use Site Plan
DAC Report of October 9, 2013
Page 9
c) Ensure that tree and other plantings do not conflict with utilities lines such as sewer,
water, stormwater, etc. and that separation distances are maintained. The proposed
screening plantings near the Dumpster enclosure may be too close to the water line. Also
check spacing of Zelkova in this same area.
d) Ensure Redbud trees are planted an adequate distance from the building to allow for
maturity.
e) Clarify how shrub plantings to the east of the south entrance door will survive under the
proposed canopy. Relocate as necessary.
RECOMMENDATIONS SUGGESTED AS CONDITIONS OF APPROVAL TO MEET CODE
OBJECTIVES:
1) Planning Staff notes that the proposed site entrance from Dover High Drive is an appropriate
location rather than an entrance off Forrest Avenue given the recent and continuing
transportation improvements in this general area. However, the applicant shall be aware of
their responsibility to seek and document the necessary easements from the adjacent property
owners and satisfy the DelDOT requirements to achieve Entrance Plan approval.
2) Planning Staff also encourages the continued efforts regarding the linkages of this church
property to the proposed water and sanitary sewer systems that are under construction and
proposed for construction in this area. However, the applicant shall be aware that timing of
construction of such services may not coincide with their own construction timing.
ADVISORY COMMENTS TO THE APPLICANT:
1) Other agencies and departments which participate in the Development Advisory Committee
may provide additional comments related to their areas of expertise and code requirements.
2) In the event, that major changes and revisions to the plan occur in the finalization of the
Conditional Use Site Plan contact the Department of Planning and Inspections. The changes
may require resubmittal for review by the Development Advisory Committee, Planning
Commission, or other agencies and commissions making recommendations in regards to the
overall Plan.
3) For building construction, the requirements of the building code or fire code must be
complied with. Consult with the Chief Building Inspector and Fire Marshal for these
requirements. The resolution of these items may impact the site design including such items
as building setbacks, building dimensions and height, building openings, and fire protection
needs, etc.
4) Construction and demolition may have an effect on the adjacent property owners and
travelers on nearby streets. Any work requiring the closing or rerouting of residents,
travelers, or visitors to the adjacent properties and streets should be coordinated as to offer
the least amount of inconvenience.
5) The applicant shall be aware that prior to any ground disturbing activities on the site the
appropriate site inspections and permits are required.
Paj 42
C-13-11 Dover Christian Church: Conditional Use Site Plan
DAC Report of October 9, 2013
Page 10
6) The applicant shall be aware that Conditional Use Site Plan approval does not represent a
Building Permit and associated construction activity permits. A separate application process
is required for issuance of a Building Permit from the City of Dover. The Building Permit
submission must comply with the conditions of approval of the pertaining to the architectural
requirements of the COZ-1.
7) The applicant shall be aware that Conditional Use Site Plan approval does not represent a
Sign Permit, nor does it convey permission to place any sign on the premises. Any proposed
site or building identification sign shall require a Sign Permit from the City of Dover prior to
placement of any such sign.
If you have any questions or need to discuss any of the above comments, please call the
above contact person and the Planning Department as soon as possible.
Paj 43
C ITY OF DOVER
DEVELOPMENT ADVISORY COMMITTEE
A PPLICATION R EVIEW C OMMENTARY
S TAFF D.A.C. MEETING DATE: OCTOBER 2, 2013
A PPLICATION : DOVER C HRISTIAN CHURCH
FILE #: C-13-11
R EVIEWING AGENCY : City of Dover Electric and Public Works Departments
CONTACT PERSON: Steve Enss - Electric
Jason A. Lyon, P.E. – Public Works
CONTACT PHONE #: E LECTRIC - 302-736-7070 / PUBLIC WORKS – 302-736-7025
T HE S UBJECT P ROPOSAL HAS BEEN R EVIEWED FOR C ODE C OMPLIANCE , P LAN C ONFORMITY AND C OMPLETENESS IN
A CCORDANCE WITH THIS A GENCY ’ S A UTHORITY AND A REA OF E XPERTISE .
T HE F OLLOWING I TEMS HAVE BEEN I DENTIFIED AS E LEMENTS W HICH N EED TO BE A DDRESSED BY THE A PPLICANT :
C ITY AND STATE CODE R EQUIREMENTS
ELECTRIC
1. Owner is responsible for following the requirements outlined in the City of Dover’s Electric Service Handbook. The
handbook is now available on the website at the following link: http://www.cityofdover.com/Public-Documents-4017/.
2. The roadway and curbing must be in.
3. The right-of-way must be within 6" of final grade.
4. The property corners must be staked.
5. Owner is responsible for locating all water, sewer, and storm sewer lines.
6. Owner is responsible for installing all conduits and equipment pads per the City of Dover Engineering Department
specifications.
7. Owner is responsible for site and/or street lighting.
8. Meter locations will be determined by City of Dover Engineering Department.
9. Load sheets and AutoCAD compatible DXF or DWG diskettes of site plans, including driveways, are required prior to
receiving approved electrical construction drawings.
10. Any relocation of existing electrical equipment will be engineered by the City of Dover Electric Department. Developer
may be required to perform a quantity of the relocation. Any work performed by the City of Dover will be at the
owner’s expense.
11. Prior to construction, owner is responsible for granting an easement to the City of Dover Electric
Department. Easement forms will be furnished and prepared by the City of Dover Electric Engineering Department.
12. Fees will be assessed upon final site plans. The owner will be responsible for fees assessed prior to
construction. Owner is required to sign off plans prepared by the Electric Department.
13. Must maintain 10' clearance around all electrical equipment, unless pre-approved by the City of Dover Electric
Engineering Department.
14. Prior to the completion of any/all designs and estimates, the owner is responsible for providing the Electric
Engineering Department with a physical address of the property.
15. All Engineering and design for Dover Electric will be engineered upon final approved plans. All Engineering work will
be furnished by the City’s Electric Engineering Department.
Paj 44
Dover Christian Church
File #: C-13-11
October 2, 2013
Page 2 of 4
WATER
1. All water utility components must meet the requirements of the Water Wastewater Handbook, effective date March 22,
2010. Please contact our office for more information.
2. The following notes must be added to the plans:
a. Hydrant connections by the contractor are prohibited. This method may not be utilized during any phase of the
project.
b. Any existing water lines not to be utilized by the proposed facility must be properly abandoned at the mains in
accordance with the City of Dover Department of Public Works specifications and requirements.
c. The site contractor shall contact the City of Dover Public Works Construction Manager at (302) 736-7025 prior to
the start of construction. A representative from the City of Dover Department of Public Works must observe and
approve all City owned water and sanitary sewer interconnections and testing. All water taps must be performed
by a City of Dover approved contractor. The proposed location for the water connection may need to be adjusted
in the field due to conditions of the existing main. Possible conditions that would require tapping relocation
include proximity to pipe joints, other taps, concrete encasements, conflict with other utilities, and the like. Test
holes must be performed by the contractor to determine the best tapping location. The City of Dover will not be
held responsible for field conditions requiring adjustment of the tapping location or for any work required by the
contractor to make an appropriate and lawful connection.
3. The size, type, and location of all proposed and existing water lines and valves must be shown on the plan.
4. Water usage projections (peak demand or plumbing fixtures) must be submitted to our office to correctly determine
the size of the domestic and irrigation (if applicable) water meter for the proposed building. These projections must be
submitted prior to approval so the meter size can be placed on the final site plan. The proposed water meter must be
installed in a pit per City of Dover requirements and manufacturer’s recommendations. Also, a dual check valve is
required downstream of the meter.
5. The domestic service, fire main connection and valves must be clearly shown for each building. A valve must be
installed at the tee to isolate combined fire and domestic water service to the building from the water loop. Typically
this valve is installed at the tee or an acceptable distance from the building. A valve must be provided on the
domestic water service, which must be tapped off of the combined eight-inch (8”) fire/domestic service outside of the
building. The domestic water tap and valve should be as close to the building as possible. Typically, the domestic tap
and valve are located within five feet (5’) to ten feet (10’) of the building. A blow up detail of this layout is
recommended.
6. Provide a construction detail for the proposed restraining system for the fire main located within the buildings. The
Department of Public Works will test and inspect all fire mains to a blind flange located inside the buildings. The blind
flange with tap is used for hydrostatic pressure testing (200 psi for two (2) hours) and dechlorination. The flange must
be restrained in the direction of the pipe entering the facility. A pipe entering horizontally through a wall sleeve shall
be restrained with rods through the wall. A pipe entering vertically through a slab shall be restrained through the floor
to the ninety degree (90) bend and thrust block. All rods shall be a minimum of ¾” all thread. All pipes through walls
and slabs must be Class 52 cement lined ductile iron pipe. Confirm particulars to meet this requirement with
mechanical designer.
7. The minimum spacing between fire hydrants and hydrant valves shall be fifteen feet (15’). (See construction detail W-
3 of the Water / Wastewater Handbook).
WASTEWATER
1. All wastewater utility components must meet the requirements of the Water Wastewater Handbook, effective date
March 22, 2010. Please contact our office for more information.
2. The following notes must be added to the plans:
a. Any existing sanitary sewer lines not to be utilized by the proposed facility must be properly abandoned at the
mains in accordance with the City of Dover Department of Public Works specifications and requirements.
b. Part II, Chapter 180, Article III, Section 180-10 of the Code of Kent County requires that “no person shall
discharge or cause to be discharged any stormwater, surface water, uncontaminated groundwater, roof runoff,
subsurface drainage, uncontaminated noncontact cooling water or unpolluted industrial process waters to any
Paj 45
Dover Christian Church
File #: C-13-11
October 2, 2013
Page 3 of 4
sanitary sewer”, this shall include condensate. Sec. 110-231 of the City of Dover Code defines storm sewer as
“…any system used for conveying rain water, surface water, condensate, cooling water or similar liquid wastes,
exclusive of sewage.” The contractor, developer, owner and designers shall ensure during construction that no
illegal discharges to the sanitary sewer system are created with the site improvements.
3. The size, length, slope, type and flow directions must be shown on all existing and proposed sanitary sewer lines.
Rim and invert elevations must be labeled on all sanitary structures, including cleanouts.
4. Cleanouts must be installed on sanitary sewer laterals within five feet (5’) of the building, one foot (1’) outside of the
right-of-way and at all bends. Any cleanout located within a traffic bearing location shall be installed with a heavy duty
cast iron frame and cover to prevent damage to the cleanout and lateral.
5. Sizing (flow) calculations must be submitted for all sanitary sewer mains showing that velocity and all other
requirements are met. Any projected future flow requirement must be clearly identified.
6. Sizing (flow) calculations must be submitted for all sanitary sewer laterals (other than for single-family dwellings)
showing that velocity and all other requirements are met.
7. The minimum size of all sanitary sewer laterals shall be six-inch (6”).
8. If kitchen facilities are proposed a minimum 1,000 gallon, two chamber grease trap, meeting all Kent County
ordinance requirements, must be provided. A construction detail for the proposed grease trap, as well as the
proposed location, must be provided on the plan.
S TORMWATER
1. Final site plan approval will not be granted until a copy of the approved Stormwater/Erosion and Sediment Control
Plan from Kent Conservation District is submitted to our office.
2. The size, length, slope, type and flow directions must be shown on all existing and proposed storm sewer lines. Rim
and invert elevations must be labeled on all stormwater structures.
S TREETS / SANITATION / GROUNDS
1. None.
GENERAL
1. All existing utilities shall be adjusted to final grade in accordance with current City of Dover requirements and
practices. This must be included as a note on the plan.
2. No trees may be planted within ten feet (10’) of underground utility infrastructure.
3. The final site plan must be submitted in the following compatible digital formats:
a. AutoCAD 2004 (.dwg format).
b. Adobe Reader (.pdf format).
RECOMMENDATIONS SUGGESTED AS CONDITIONS OF APPROVAL TO MEET CODE OBJECTIVES
ELECTRIC
1. Owner must give the City of Dover Electric Department three (3) month notice prior to construction. Owner is
responsible for following the requirements outlined in the City of Dover’s Electric Service Handbook. The handbook is
now available on the website at the following link: http://www.cityofdover.com/departments/electric/documents/.
WATER / WASTEWATER / STORMWATER / STREETS /SANITATION / GROUNDS / GENERAL
1. None.
A DVISORY COMMENTS TO THE A PPLICANT
ELECTRIC
1. None
WATER
Paj 46
Dover Christian Church
File #: C-13-11
October 2, 2013
Page 4 of 4
1. It is recommended that the developer coordinate with the Leander Lakes development to the south to obtain water
service. If the water infrastructure necessary for service is not installed prior to construction of this project, the
developer shall provide another method of connecting to water services. The developer is responsible for all costs
associated with extending and providing service to the proposed development.
2. Prior to plan approval, the water system plans must be submitted to the Division of Public Health, Office of Drinking
Water for review and approval. The owner/developer will be responsible for providing all completed forms and plan
sets to the City of Dover as required for submission to the Office of Drinking Water. Plans will not be submitted to the
Office of Drinking Water until review has been completed by our office.
3. Hydrant flow testing is currently only performed during the spring and fall. The applicant must call the Department of
Public Works directly to schedule these tests. This applies to both existing hydrants as well as those proposed for the
site.
WASTEWATER
1. It is recommended that the developer coordinate with the Leander Lakes development to the south to obtain
wastewater service. If the wastewater infrastructure necessary for service is not installed prior to the construction of
this project, the developer shall provide another method of connecting to wastewater service. The developer is
responsible for all costs associated with extending and providing service and capacity to the proposed development.
2. Prior to plan approval, the sanitary sewer system plans may be required to be submitted to the DNREC, Division of
Water Resources, Surface Water Discharges Section for review and approval. The owner/developer is responsible
for providing all application fees, completed forms and plan sets directly to DNREC.
SANITATION
1. Sanitation service must be provided by a private contractor.
S TORMWATER / S TREETS / G ROUNDS
1. None
GENERAL
1. Construction plans will not be reviewed by our office unless all previous comments have been clearly addressed
within the plan set and accordingly identified within an itemized response letter and with the Water/Wastewater Initial
Plan Submission Checklist, which can be obtained from the following website: https://imageserv9.team-
logic.com/mediaLibrary/198/WaterWastewaterHandbookFinal_1.pdf, page 88.
I F Y OU H AVE A NY Q UESTIONS OR N EED TO D ISCUSS ANY OF THE A BOVE C OMMENTS , P LEASE C ALL THE A BOVE
C ONTACT P ERSON AND THE P LANNING D EPARTMENT AS S OON AS P OSSIBLE .
Paj 47
C F
I I
CITY OF DOVER T R
Y E
DEVELOPMENT ADVISORY COMMITTEE
O M
APPLICATION REVIEW COMMENTARY F A
R
D.A.C. MEETING DATE: D S
O H
V A
E L
R
APPLICATION: Dover Christian Church 1738 Forrest Ave
FILE #: C-13-11 REVIEWING AGENCY: City of Dover, Office of the Fire Marshal
CONTACT PERSON: David Truax, Fire Marshal PHONE #: (302) 736-7011
THE SUBJECT PROPOSAL HAS BEEN REVIEWED FOR CODE COMPLIANCE, PLAN CONFORMITY,
AND COMPLETENESS IN ACCORDANCE WITH THIS AGENCY’S AUTHORITY AND AREA OF
EXPERTISE.
THE FOLLOWING ITEMS HAVE BEEN IDENTIFIED AS ELEMENTS WHICH NEED TO BE ADDRESS BY
THE APPLICANT:
CITY AND STATE CODE REQUIREMENTS:
Proposed building is 9,600 Sq. Ft assembly occupancy. Submitted fire lanes are ok. Show
required perimeter access on drawing.
Any gas fired HVAC equipment must be equipped with emergency cutoff switches remotely
located.
Address numbers of at least 12 inches in height must be placed on the street side of the building
visible from the street.
Any natural or LP gas bottles, meters, values, regulators, etc., must have impact protection.
Full building and fire plan review is required.
Building cannot be occupied or construction or renovations started until completion of building
and fire plan review.
All required means of egress shall have an exit discharge consisting of a non slip surface, and
leading to and terminating at a public way.
Sprinkler system required. System to be monitored.
Paj 48
Fire alarm system required. Voice Evac if over 300 persons.
Knox Box required.
Project to be completed per approved Site Plan.
RECOMMENDATIONS SUGGESTED AS CONDITIONS OF APPROVAL TO MEET CODE
OBJECTIVES:
ADVISORY COMMENTS TO THE APPLICANT:
After any application has been approved by the Planning Commission, the applicant has a
maximum of thirty (30) days to appeal to the Code Board of Appeals Committee.
All comments from this office, approved by the Planning Commission are at the expense of the
owner/applicant.
The proposed building will be reviewed under Assembly Occupancy.
The City of Dover uses the 2012 NFPA Life Safety Code, 2009 IBC, latest editions of all other
NFPA Codes and the 2012 Delaware State Fire Prevention Regulations.
The Dover Fire Department request that a 8 ½ X 11 copy of the floor plan and site plan be
submitted to Station 1, attention Fire Chief, prior to the Certificate of Occupancy being issued.
If you have any questions or need to discuss any of the above comments, please call the
above contact person and the Planning Department as soon as possible.
Paj 49
CITY OF DOVER D
E
DEVELOPMENT ADVISORY COMMITTEE
L
APPLICATION REVIEW COMMENTARY D
O
D.A.C. MEETING DATE: October 2, 2013 T
===============================================================
APPLICATION: Dover Christian Church
FILE#: C-13-11 REVIEWING AGENCY: DelDOT
CONTACT PERSON: Julio F. Seneus PHONE#: 760-2145
===============================================================
THE SUBJECT PROPOSAL HAS BEEN REVIEWED FOR CODE COMPLIANCE, PLAN CONFORMITY AND COMPLETENESS IN
ACCORDANCE WITH THIS AGENCY'S AUTHORITY AND AREA OF EXPERTISE.
THE FOLLOWING ITEMS HAVE BEEN IDENTIFIED AS ELEMENTS WHICH NEED TO BE ADDRESSED BY THE APPLICANT:
CITY & STATE CODE REQUIREMENTS:
1. The proposed entrance location on Dover High Drive is within the proposed
stormwater bay area of Leander Lake Apartments project. The Department
recommends the necessary coordination between the two projects in order to resolve
this issue.
2. In order to be issued a Letter of No Objection (LONO), the department will require
the applicant to provide the proper forms, fees, and plans.
3. A Traffic Impact Study (TIS) will be required for this project, since the proposed
development exceeds 50 VPH (Vehicle per Hour) or 400 VPD (Vehicle per Day).
When the study is completed, DelDOT will review it and send the recommendations
of the improvements to the City. The improvements contained in the study will be
implemented by the developer per DelDOT's discretion. To set up a scoping meeting
for this project, please contact Mr. Troy Brestel at (302) 760-2167 or via e-mail at
Troy.Brestel@state.de.us. In addition, the department will allow a payment towards
an Area-Wide Study Fee for the additional trips, in lieu of performing the TIS. The
Area-Wide Study Fee is calculated at $10 per daily trip, and it would be payable to
DelDOT prior to the issuance of a Letter of No Objection. Payment of the TIS would
exempt the developer from performing the study, but would not exempt them from
participation in off-site improvements or a Traffic Operational Analysis if one is
required during the review of the entrance plans. If the developers would like to pay
the fee in lieu of doing a TIS, the developer should contact me at (302) 760-2145.
4. The applicant will be required to provide a monetary contribution towards the
installation of the traffic signal at the intersection of Forest Avenue and the Dover
High Drive.
Paj 50
5. The proposed monument sign cannot be located within the 15-foot permanent
easement (PE) along the site frontage.
RECOMMENDATIONS SUGGESTED AS CONDITIONS OF APPROVAL TO MEET CODE
OBJECTIVES:
ADVISORY COMMENTS TO THE APPLICANT:
If you have any questions or need to discuss any of the above comments, please call the
above contact person and the planning department as soon as possible.
Paj 51
CITY OF DOVER
DEVELOPMENT ADVISORY COMMITTEE
APPLICATION REVIEW COMMENTARY
October 2013
APPLICATION: Dover Christian Church
FILE #: C-13-11
REVIEWING AGENCY: Kent Conservation District
CONTACT PERSON: David C. Cahill PHONE #: 741-2600 ext.3
THE SUBJECT PROPOSAL HAS BEEN REVIEWED FOR CODE COMPLIANCE, PLAN CONFORMITY AND COMPLETENESS
IN ACCORDANCE WITH THIS AGENCY’S AUTHORITY AND AREA OF EXPERTISE. THE FOLLOWING ITEMS HAVE BEEN
IDENTIFIED AS ELEMENTS WHICH NEED TO BE ADDRESSED BY THE APPLICANT:
CITY AND STATE CODE REQUIREMENTS:
1. Kent Conservation District has no objection to conditional use site plan of the above referenced site.
ADVISORY COMMENTS TO THE APPLICANT:
The Following comments are advisory and apply to the development of a detailed site plan for this project.
1. Land disturbing activities in excess of 5,000 square feet are regulated under the Delaware Sediment
and Stormwater Regulations. A detailed sediment and stormwater management plan must be reviewed
and approved by the Kent Conservation District prior to any land disturbing activity (i.e. clearing,
grubbing, filling, grading, etc.) taking place.
2. A pre application meeting with the site engineer shall be required with the Conservation District prior
to plans being submitted for review.
Paj 52
CITY OF DOVER Dover/Kent
County
DEVELOPMENT ADVISORY COMMITTEE
Metropolitan
APPLICATION REVIEW COMMENTARY Planning
Organization
D.A.C. MEETING DATE: 10/9/13
APPLICATION: Dover Christian Church on Forest Avenue
FILE #: C-13-11 REVIEWING AGENCY: Dover/Kent County MPO
CONTACT PERSON: James Galvin, AICP PHONE #: (302) 387-6030
The Dover/Kent County MPO has participated in the State’s Preliminary Land Use Services (PLUS) process for several
months. The MPO requested the opportunity to bring the recommendations on issues of our concern to the City as well. The
MPO will limit comments to projects to development proposals and applications that may lead to new development. Issues
of concern to the MPO are effective transit, reducing the amount of vehicle emissions by shortening or eliminating trips, and
facilities for alternative modes of transportation, including bicycle and pedestrian access. The MPO considers the bicycle
facilities required by the City of Dover to be the standard for all applications, not to be waived.
City of Dover Planning Commission 10/21/2013
Project Review
C-13-11 Dover Christian Church on Forrest Avenue
the site design for this property considers many of the elements under the MPO’s purview. It has reasonable
pedestrian access to the site both from DE 8/Forrest Avenue and from Dover High Drive.
The development of the Dover High School and in the potential development of Leander Lakes Apartments on
the adjacent parcels will likely require review by the Delaware Transit Corporation for the location of a new bus
stop. The applicant should coordinate with the adjacent applicants/owners to bring bus service to the area at the
discretion of the Delaware Transit Corporation.
If you have any questions or need to discuss any of the above comments, please call the above
contact person and the Planning Department as soon as possible.
Paj 88
City of Dover
REVISED
DATA SHEET FOR RECREATION PLAN REVIEW
PARKS, RECREATION AND COMMUNITY ENHANCEMENT COMMITTEE
MEETING OF September 9, 2013
Plan Title: Walker Woods/Walker Woods II (Village of Sherwood)
File Number: MI-13-17
Plan Type: Active Recreation Area Plan
Location: North Side of Walker Road East of Kenton Road
Owner: Walker Woods Properties, LLC
Milford Housing Development Corporation
Site Area: 77 Residential Units on 9.0722 ± acres
Property Use: Proposed Apartments
Number of Dwelling Units: Total - 77 dwelling units proposed
Zoning Classification: Current Zoning – RG-3 (Group Housing Zone) and ROS
(Recreation and Open Space Zone)
Proposed Zoning – RG-2 (General Residence Zone) – City
Council will act on rezoning request on September 9, 2013.
(Application #Z-13-02/ Ordinance #2013-13)
PROJECT SUMMARY
The proposed project is to redevelop Walker Woods and Walker Woods II into an apartment
complex. This will include consolidation of the parcels that currently make up the townhouse
community. The proposed project includes 77 dwelling units on 9.0722 acres, which is a density
of approximately 8.5 dwelling units per acre. Therefore, the development qualifies for the open
space exemption in the Zoning Ordinance, Article 5 – Supplementary Regulations, § 10.5:
10.514 Residential developments of ten (10) or fewer acres with a density over six units per
acre. These developments shall be exempt from the area requirements set forth in section 10.16,
but shall be required to provide 150 square feet of active recreation area per dwelling unit or
10,000 square feet of active recreation area, whichever is greater. If the commission determines
that the construction of some or all of the required active recreation area is not practical or
desirable, the commission shall require a cash in lieu donation for the active recreation area
determined as not practical or desirable. Cash-in-lieu amount shall be in accordance with
subsection 10.173 of this article.
P. O. Box 475 Dover, DE 19903
Community Excellence Through Quality Service
Paj 89
Walker Woods/Walker Woods II Redevelopment: Recreation Area Plan
Summary Report of Active Recreation Component
Parks, Recreation & Community Enhancement Committee Meeting on September 9, 2013
Page 2 of 3
Proposal for Active Recreation Plan
Based on the proposed 77 dwelling units and 150 square feet of recreation area required per unit,
the site is required to have 11,550 square feet of recreation area. The applicant has proposed to
meet this requirement through a variety of amenities throughout the development. On the
southwest portion of the site, there is a community center building with meeting rooms and
activity rooms. A playground area is adjacent to this community center. A small tot lot is
proposed on the east side of the site. On the east side of the site there is also an ADA accessible
picnic area. There is also a proposed five-foot-wide mulch path leading from the picnic area to
the end of the cul de sac and an ADA accessible path extended from this to the west side of the
site where the playground is. There are three (3) 15’x12’ exercise stations proposed throughout
the development.
In addition to these amenities, the applicant has proposed a series of benches and relaxation
stations scattered through the development. The relaxation stations include a bench, trash
receptacle, recycling receptacle, and smoking receptacle on a concrete pad. There are four (4)
relaxation stations and nine (9) stand-alone benches distributed throughout the proposed
development.
The plan shows tree plantings throughout the development, including areas adjacent to the
recreation amenities.
The following table provides information from the submitted Plan for the Active Recreation
Area:
Required Provided on Plan
Active Recreation 150 S.F. per dwelling unit 11,567 SF provided as
Area or a minimum of 10,000 follows:
(Article 5 §10.514) SF • Community Center
77 DU = 11,550 SF Meeting and Activity
required Rooms
• Playground
• Age Oriented to • Tot Lot
development • 5’ wide mulch path
• Parking • ADA accessible path
• Setbacks: 30 feet from • ADA picnic area with
residential lots and 25 table and grill
feet from right-of-way • 9 benches
for street • Covered public area
• Landscaping • 4 relaxation stations
• 3 Exercise stations
STAFF RECOMMENDATIONS
The following are comments and recommendations from Staff of the Department of Planning &
Inspections following review of the Active Recreation Area Plan.
Paj 90
Walker Woods/Walker Woods II Redevelopment: Recreation Area Plan
Summary Report of Active Recreation Component
Parks, Recreation & Community Enhancement Committee Meeting on September 9, 2013
Page 3 of 3
1. Staff recommends approval of the Active Recreation Area Plan as submitted with the
following recommended changes:
a. Please provide additional detail on what amenities will be provided as a part of
the exercise stations.
b. The mulch path should include a defined edging that will prevent encroachment
of grass and/or weeds into the mulch path area.
c. Include a grill at the picnic area.
2. The ability of the Site Development Plan for this project to move forward is subject to
City Council approval of the rezoning application (Z-13-02), which is scheduled for City
Council Action on Monday, September 9, 2013.
3. The project, including the Active Recreation Plan, is subject to review and approval of
the Site Development Plan by the Planning Commission, which includes:
a. Review of the building architecture for the community center;
b. Compliance of Site Development Plan with tree planning and landscape
requirements in the Zoning Ordinance, Article 5 – Supplementary Regulations,
§15 Landscape Guidelines and §16 Tree Planting and Preservation.
4. The applicant is reminded of the requirements for construction phasing of the recreation
area as associated with the development of the residential units.
10.6 Construction phasing. The recreation and open space areas shall be completed in a
proportion equal to or greater than the proportion of residential dwelling units completed,
except that 100 percent of the recreation and open space areas shall be completed prior
to issuing building permits for the final 20 percent of the dwelling units proposed. Building
permits shall not be issued for dwelling units unless the requirements of this section are
met.
5. There shall be provisions which ensure that the common open space land and community
room (including active recreation area) shall continue as such and be properly managed
and maintained. The developer shall either retain ownership and responsibility for
maintenance of such open land; or provide for and establish one (1) or more
organizations for the maintenance of all common open space.
a. Add a note on the Site Plan regarding who is responsible for maintenance, and
insurance on the common open space.
The Parks, Recreation, and Community Enhancement Committee shall submit to the Planning
Commission a report detailing the recommendations as to the Recreation Area Plan.
Paj 91
City of Dover
DATA SHEET FOR SITE PLAN REVIEW
DEVELOPMENT ADVISORY COMMITTEE MEETING OF October 9, 2013
PLANNING COMMISSION MEETING OF October 21, 2013
Plan Title: Woodmill Apartments Storage Buildings, Garage Building and
Revised Active Recreation Area
S-13-19
Plan Type: Site Plan
Revised Recreation Area Plan and 6-unit Garage Building
Property Location: South side of Farmview Drive and east of Mifflin Road
Property Address: 1300 South Farmview Drive
Tax Parcels: ED-05-076.10-02-07.01-000
ED-05-076.10-02-56.00-000
Owners: Multi-residential
Multi-residential-M, LLC
Present Zoning: RG-2 (General Residence Zone)
Existing Use: Apartment Complex
Proposed Use: Apartment Complex with storage buildings and 6-unit garage
building
Site Area: 8.553 ac. +/- (north parcel)
5.630 ac. +/- (south parcel)
14.183 ac. +/- (total of both parcels)
Building Area: Proposed – 2 storage buildings for a total of 8,800 S.F.
Proposed – 6 unit garage building for a total of 1,632 S.F.
Waivers Requested: None
P. O. Box 475 Dover, DE 19903
Community Excellence Through Quality Service
Paj 92
CITY OF DOVER City of
DEVELOPMENT ADVISORY COMMITTEE
Dover
Planning
APPLICATION REVIEW COMMENTARY Office
D.A.C. MEETING DATE: October 9, 2013
APPLICATION: Woodmill Apartments Storage Buildings, 6 Unit Garage Building and Revised
Active Recreation Area
FILE #: S-13-19 REVIEWING AGENCY: City of Dover Planning
CONTACT PERSON: Tracey Harvey PHONE #: (302) 736-7196
PLAN SUMMARY:
This Plan is for review of the Site Plan for the construction of two (2) storage buildings for a
total of 8,800 SF, one 6-unit garage building for a total of 1,632 SF and revisions to the Active
Recreation Area for the apartment complex. The revisions to the Active Recreation Area are to
remove the two (2) existing tennis courts and replace with the two (2) storage buildings. New
Active Recreation Area in the form of open space, a picnic table and horseshoe pit will be
established on the west side of the property. The project area consists of two parcels of land
zoned RG-2 (General Residence Zone). The property site is located at the south side of
Farmview Drive and east of Mifflin Road. The owners of record are Multi-residential and
Multi-residential-M, LLC. The property address is 1300 South Farmview Drive. Tax Parcels:
ED-05-076.10-02-07.01-000 and ED-05-076.10-02-56.00-000. The application partially
supersedes S-13-11 Woodmill Apartment Storage Building and Revised Active Recreation Area;
information on the Revised Active Recreation Area will be applicable to S-13-19.
The apartment complex consists of two (2) parcels of land with eight (8) apartment buildings
between the two parcels. The parcel to the north has five (5) buildings and the Active Recreation
Area. All of the Active Recreation Area is on this parcel. On the east side of the parcel is the
swimming pool, clubhouse, volleyball court, and tennis courts. The swimming pool was
constructed as part of a Site Plan (S-00-7). There is a playground located on the west side of the
parcel. The parcel to the south has three (3) buildings. The apartment complex was constructed
in several phases between 1987 through 1990 (S-90-5). The complex was constructed prior to
the Zoning Ordinance requiring Active Recreation Area. The site is considered legal non-
conforming with regards to Active Recreation Area.
ACTIVE RECREATION AREA
Parks, Recreation and Community Enhancement Committee
The revisions to the Active Recreation Area were reviewed by the Parks, Recreation, and
Community Enhancement Committee at their meeting on April 8, 2013. The revisions include
the removal of the two (2) tennis courts, the placement of a picnic table, open space, and
Paj 93
S-13-19 Woodmill Apartments Storage Building and Garage Building
FINAL DAC Report for October 9, 2013
Page 2 of 6
horseshoe pit on the west side of the property with the existing playground. Based on 258 units
the complex requires 1.6288 acres of Active Recreation Area. The revisions will provide 1.75
acre of Active Recreation Area. The Committee recommended approval of the plan with staff
comments. The Active Recreation Review Report is attached.
Required Provided on Revised Plan
Active Recreation Area 275 S.F. per dwelling unit or East: Clubhouse, swimming
(Article 5 §10.16) 0.5 acre, greater thereof pool, volleyball court,
258 DU = 70,950 S.F. West: lawn area, horseshoe pit,
(1.6288 ac) picnic table, and playground
Requires 1.6288 acres area
Total of 1.75 acres
Active Recreation Amenities Accessibility Distributed throughout the
(Article 5 §10.15) development. Accessible
access to the community
building, volleyball court, and
swimming pool. The complex
lacks sidewalks throughout the
development.
Active Recreation Amenities Age Oriented to Clubhouse
(Article 5 §10.15) development Playground Area Equipment
Swimming pool
Volleyball court
Horseshoe pit
Picnic Table
Parking Off-street parking provided for
each dwelling unit on the
parcels. There are 34 parking
spaces located near the
Clubhouse and swimming pool.
Setbacks: 30 feet from Clubhouse and volleyball court
residential lots and 25 feet are legal non-conforming as
from right-of-way for street they are located within 30 feet
of the property line. The
playground and swimming pool
are in compliance with the
setbacks as required. The other
areas shall comply with the 30
foot setback.
Landscaping The Revised Active Recreation
Plan shows woodland around
the proposed area.
Two (2) parking spaces will be eliminated along the Active Recreation Area in order to provide
access to the Area and two (2) new parking spaces will be constructed between Buildings G and
H at the north end of the property to replace the removed spaces.
Paj 94
S-13-19 Woodmill Apartments Storage Building and Garage Building
FINAL DAC Report for October 9, 2013
Page 3 of 6
PHASE 1: 6 UNIT GARAGE BUILDING
The plan is for the construction of a six (6) unit garage building at 1,632 SF for the use of the
current residents for the apartment complex. The proposed building will be constructed in the
first phase in the parking lot on the east side of Apartment Building L on Parcel 3. The garage
consists of six (6) interior parking spaces. The construction of the garage building will occupy
the current location of eight (8) existing parking spaces.
PHASE 2 AND 3 STORAGE BUILDINGS
The plan is for the construction of two (2) storage buildings for the use by the current residents
for the apartment complex. The storage buildings will replace the existing tennis courts. The
building to the south (Phase 2) is at 4,800 SF. The building to the north (Phase 3) is 4,000 SF.
The storage buildings are proposed to be constructed in two phases. The south building is
proposed to be constructed in the second phase. The north building is proposed to be built within
the third phase. The construction of the second building shall be completed within one year of
the issuance of a Certificate of Occupancy for the first building or prior to the expiration of the
Site Plan.
Parking Summary
In the RG-2 (General Residence Zone), based on the current parking requirements there are 2.25
off street parking spaces required for each dwelling unit (2 parking spaces per dwelling unit and
0.25 parking spaces for visitors per dwelling unit). Based on the number of 258 dwelling units a
total of 581 parking spaces are required. There are 477 existing parking spaces included on the
plan. Since the project does not increase the number of dwelling units on the site, the existing
parking will be considered legal non-conforming. A total of twenty-three (23) handicap parking
spaces have been included on the Plan. The storage buildings are considered accessory structures
and do not require additional parking as they are for use by current tenants of the apartment
complex only. The applicant notes that with the proposed construction of the six (6) unit garage a
total of eight (8) parking spaces will be removed and two (2) parking spaces will be relocated in
the parking lot on the south end of Building N on Parcel 3. The existing cross striping in the
parking spaces will be removed to create two (2) parking spaces.
Bicycle Parking
The site is required to provide bicycle parking. The bicycle parking calculation is one for every
twenty parking spaces. Based on the number of required parking spaces thirty (30) bicycle
parking spaces are required.
SITE CONSIDERATIONS
Dumpsters
There are existing dumpster pads and enclosures throughout the apartment complex.
Sidewalks
The site has existing sidewalks around the swimming pool and clubhouse. There are also
sidewalks leading into the buildings.
Lighting
There is existing lighting provided on the site.
Paj 95
S-13-19 Woodmill Apartments Storage Building and Garage Building
FINAL DAC Report for October 9, 2013
Page 4 of 6
Curbing
There is limited curbing within the parking areas on the site. There are parking bumpers placed
at each parking space. This is an existing condition and is not impacted by the construction of
the storage buildings or garage building.
BUILDING ARCHITECTURE (Drawings dated 9/6/13):
The submission Plan includes the proposed Architectural Elevation drawings for the storage
buildings and the garage. The storage buildings and garage will have a pitched roof with asphalt
shingles, siding, and large doors on the west side for access for the storage buildings. The
storage buildings and garage will reflect the architecture of the existing garages located on the
site.
TREE PLANTING AND LANDSCAPE PLAN
The submitted plan includes the Landscaping details. Based on the 361,217 S.F. of non-
woodland area (8.2924 ac. +/- for Site Plan property) for Parcel 2, a total of 121 trees are
required. The plan proposes the planting of twenty-five (25) new trees to meet the requirement.
There are 96 existing trees on the property. The tree planting requirement for parcel 2 has been
met. Based on the 228,461 S. F. of non-woodland area (5.2447 ac. +/- for Site Plan property) for
Parcel 3, a total of 76 trees are required. The plan proposes the planting of fifty-three (53)
proposed trees; however, there are forty-nine (49) shown on the plan. There are 25 existing trees
on the property. Parcel 3 does not meet the tree planting requirement. The new trees will be
located within Parcel 2 and Parcel 3. The proposed trees are a mixture of shade and ornamental
trees. The mixture includes Honey Locust, Red Cedar, Crape Myrtle, Sweetbay Magnolia,
White Pine, White Oak, Willow Oak and Village Green Zelkova. For the tree planting
calculation, the two parcels of land on which the buildings are being constructed are being used.
THE SUBJECT PROPOSAL HAS BEEN REVIEWED FOR CODE COMPLIANCE, PLAN
CONFORMITY, AND COMPLETENESS IN ACCORDANCE WITH THIS AGENCY’S
AUTHORITY AND AREA OF EXPERTISE.
CITY AND STATE CODE REQUIREMENTS:
1) The project data column needs to be updated prior to Final Approval. Some of the items
which need revising are as follows:
a) A total of 581 parking spaces are required based on the number of apartment units and
the current parking requirement. There are 477 spaces included on the plan. Since there
will not be any construction of apartment buildings increasing the number of dwelling
units on the site, the existing parking will be considered legal non-conforming. However,
any impact to the existing number of parking spaces must be compensated for with this
project. Add a note to the plan the parking is considered legal non-conforming.
b) Based on the bicycle parking calculation for 1 space for every 20 parking spaces, a total
of 30 parking spaces are required. There are twenty-five (25) on the plan. Seventeen (17)
parking spaces are required for Parcel 2 and thirteen (13) parking spaces are required for
Parcel 3. Identify five (5) additional bicycle parking spaces on the plan. Add the bicycle
parking calculation to the plan.
Paj 96
S-13-19 Woodmill Apartments Storage Building and Garage Building
FINAL DAC Report for October 9, 2013
Page 5 of 6
2) Clarify the number of parking spaces that will be removed for the proposed 6-unit garage.
3) Revise the number of proposed trees that will be planted on Parcel 3. The tree planting
calculation for Parcel 3 requires a total of seventy-six (76) trees. There are 25 existing trees
on the site, and 53 proposed in the data column; however, there are 49 proposed trees on the
plan. Two (2) trees need to be added to meet this requirement.
a) Revise the number of proposed trees on the Landscape Plan to reflect the actual number
of proposed trees.
4) Provide a note indicating if the storage buildings will be climate controlled.
5) A City of Dover Business License is required for each individual landscape architect
professional engineer, or professional land surveyor doing business within the City. The City
of Dover Business License application can be found on the city’s website,
www.cityofdover.com. A City of Dover Business License for each individual engineer,
architect, or landscape architect shall be obtained prior to Final Site Plan Approval. Please
contact the Planning and Inspections Department at 302-736-7010 with any questions.
6) The construction of the second and third building of this project shall be started within one
year of the issuance of a Certificate of Occupancy for the previous building or prior to the
expiration of the Site Plan. The improvements to the Active Recreation Area must be
completed prior to issuance of a Certificate of Occupancy for the first Storage Building.
RECOMMENDATIONS SUGGESTED AS CONDITIONS OF APPROVAL TO MEET CODE
OBJECTIVES:
1) Staff recommends the addition of additional picnic tables and/or benches within the
proposed Active Recreation Area on the west side of the property.
2) Staff recommends the addition of at least one grill within the proposed Active Recreation
Area on the west side of the property.
3) Staff recommends the addition of evergreen trees on the north end of the Active
Recreation Area as additional screening from adjacent residences.
4) Staff recommends the architecture of the storage buildings have a pitched roof, horizontal
siding, a similar color to the apartment buildings and other details found in the apartment
buildings.
5) Staff recommends the architecture of the 6 unit garage building have a pitched roof,
horizontal siding, a similar color to the apartment buildings and other details found in the
apartment buildings.
ADVISORY COMMENTS TO THE APPLICANT:
1) The storage buildings and garage shall be for use by the residents of the apartment complex
only. The storage buildings and garage shall not be used by other people or organizations
outside of the apartment complex. A note to this effect must be listed on the Site Plan.
Paj 97
S-13-19 Woodmill Apartments Storage Building and Garage Building
FINAL DAC Report for October 9, 2013
Page 6 of 6
2) Other agencies and departments which participate in the Development Advisory Committee
may provide additional comments related to their areas of expertise and code requirements.
3) Following Planning Commission approval of the Site Plan, the Plan must be revised to meet
all conditions of approval from the Development Advisory Committee or as otherwise noted.
A Check Print must be submitted for review by Planning Office Staff. Upon determination
that the Plan is complete and all agency approvals have been received, copies of the Plan
may be submitted for final endorsement.
4) In the event, that major changes and revisions to the Site Plan occur in the finalization of the
Site Plan contact the Department of Planning and Inspections. These changes may require
resubmittal for review by the Development Advisory Committee, Planning Commission, or
other commissions making recommendations in regards to the plan.
5) There shall be provisions which ensure that the common open space land (including Active
Recreation Area) shall continue as such and be properly managed and maintained.
6) Construction may have an effect on the existing Active Recreation Area. Any work
requiring the closing or rerouting of uses to the existing amenities should be coordinated as
to offer the least amount of inconvenience.
7) For building construction, the requirements of the building code or fire code must be
complied with. Consult with the Chief Building Inspector and Fire Marshal for these
requirements. The resolution of these items may impact the site design including such items
as building setbacks from property line, building dimensions and height, building openings,
and fire protection needs, etc.
8) The applicant/developer shall be aware that prior to any ground disturbing activities on the
site the appropriate site inspections and permits are required.
9) The applicant shall be aware that Site Plan approval does not represent a Building Permit and
associated construction activity permits. A separate application process is required for
issuance of a Building Permit from the City of Dover.
10) The applicant shall be aware that Site Plan approval does not represent a Sign Permit, nor
does it convey permission to place any sign on the premises. Any proposed site or building
identification sign shall require a Sign Permit from the City of Dover prior to placement of
any such sign.
If you have any questions or need to discuss any of the above comments, please call the
above contact person and the Planning Department as soon as possible.
Paj 98
CITY OF DOVER
DEVELOPMENT ADVISORY COMMITTEE
APPLICATION REVIEW COMMENTARY
STAFF D.A.C. MEETING DATE: OCTOBER 2, 2013
APPLICATION: Woodmill Apartments Storage Buildings & Garage
Building and Revised Active Recreation Area
FILE #: S-13-19
REVIEWING AGENCY: City of Dover Electric and Public Works Departments
CONTACT PERSON: Steve Enss - Electric
Jason A. Lyon, P.E. – Public Works
CONTACT PHONE #: Electric - 302-736-7070 Public Works – 302-736-7025
T HE S UBJECT P ROPOSAL HAS BEEN R EVIEWED FOR C ODE C OMPLIANCE , P LAN C ONFORMITY AND C OMPLETENESS IN
A CCORDANCE WITH THIS A GENCY ’ S A UTHORITY AND A REA OF E XPERTISE .
T HE F OLLOWING I TEMS HAVE BEEN I DENTIFIED AS E LEMENTS W HICH N EED TO BE A DDRESSED BY THE A PPLICANT :
CITY AND STATE CODE REQUIREMENTS
ELECTRIC
1. The roadway and curbing must be in.
2. The right-of-way must be within 6" of final grade.
3. The property corners must be staked.
4. Owner is responsible for locating all water, sewer, and storm sewer lines.
5. Owner is responsible for installing all conduits and equipment pads per the City of Dover Engineering Department
specifications.
6. Owner is responsible for site and/or street lighting.
7. Meter locations will be determined by City of Dover Engineering Department.
8. Load sheets and AutoCAD compatible DXF or DWG diskettes of site plans, including driveways, are required prior to
receiving approved electrical construction drawings.
9. Any relocation of existing electrical equipment will be engineered by the City of Dover Electric Department. Developer
may be required to perform a quantity of the relocation. Any work performed by the City of Dover will be at the
owner’s expense.
10. Prior to construction, owner is responsible for granting an easement to the City of Dover Electric Department.
Easement forms will be furnished and prepared by the City of Dover Electric Engineering Department.
11. Fees will be assessed upon final site plans. The owner will be responsible for fees assessed prior to construction.
Owner is required to sign off plans prepared by the Electric Department.
12. Must maintain 10' clearance around all electrical equipment, unless pre-approved by the City of Dover Electric
Engineering Department.
13. Prior to the completion of any/all designs and estimates, the owner is responsible for providing the Electric
Engineering Department with a physical address of the property.
14. All Engineering and design for Dover Electric will be engineered upon final approved plans. All Engineering work will
be furnished by the City’s Electric Engineering Department.
Paj 99
Woodmill Apartments Storage Buildings & Garage Building; Revised Active Recreation Area
File #: S-13-19
October 2, 2013
Page 2 of 2
WATER
1. Per the Water / Wastewater Handbook, “No structures, including permanent signage, may be located within ten feet
(10’) of water infrastructure, please locate any water infrastructure on the plan to verify the proposed improvements do
not conflict with any underground water infrastructure.
WASTEWATER
1. Per the Water / Wastewater Handbook, “No structures, including permanent signage, may be located within ten feet
(10’) of water infrastructure, please locate any wastewater infrastructure on the plan to verify the proposed
improvements do not conflict with any underground wastewater infrastructure.
STORMWATER
1. Final site plan approval will not be granted until a copy of the approved Stormwater/Erosion and Sediment Control
Plan from Kent Conservation District is submitted to our office.
STREETS / SANITATION / GROUNDS
1. None
GENERAL
1. The final site plan must be submitted in the following compatible digital formats:
a. AutoCAD 2004 (.dwg format).
b. Adobe Reader (.pdf format).
RECOMMENDATIONS SUGGESTED AS CONDITIONS OF APPROVAL TO MEET CODE OBJECTIVES
ELECTRIC
1. Owner must give the City of Dover Electric Department three (3) months notice prior to construction. Owner is
responsible for following the requirements outlined in the City of Dover’s Electric Service Handbook. The handbook is
now available on the website at the following link: http://www.cityofdover.com/departments/electric/documents/.
WATER / WASTEWATER / STORMWATER / STREETS / SANITATION / GROUNDS / GENERAL
1. None.
ADVISORY COMMENTS TO THE APPLICANT
ELECTRIC
1.
WATER
1. Be advised that if the fire suppression is required, further review will be provided by the Department of Public Works.
WASTEWATER / STORMWATER / STREETS / SANITATION / GROUNDS
1. None.
GENERAL
1. Construction plans will not be reviewed by our office unless all previous comments have been clearly addressed
within the plan set and accordingly identified within an itemized response letter and with the Water/Wastewater Initial
Plan Submission Checklist, which can be obtained from the following website: https://imageserv9.team-
logic.com/mediaLibrary/198/WaterWastewaterHandbookFinal_1.pdf, page 88.
I F Y OU H AVE A NY Q UESTIONS OR N EED TO D ISCUSS ANY OF THE A BOVE C OMMENTS , P LEASE C ALL THE A BOVE
C ONTACT P ERSON AND THE P LANNING D EPARTMENT AS S OON AS P OSSIBLE .
Paj 100
C F
I I
CITY OF DOVER T R
Y E
DEVELOPMENT ADVISORY COMMITTEE
O M
APPLICATION REVIEW COMMENTARY F A
R
D.A.C. MEETING DATE: May 1, 2013 D S
O H
V A
E L
R
APPLICATION: Woodmill Apartment Storage Buildings
FILE #: S-13-11 REVIEWING AGENCY: City of Dover, Office of the Fire Marshal
CONTACT PERSON: David Truax, Fire Marshal PHONE #: (302) 736-7011
THE SUBJECT PROPOSAL HAS BEEN REVIEWED FOR CODE COMPLIANCE, PLAN CONFORMITY,
AND COMPLETENESS IN ACCORDANCE WITH THIS AGENCY’S AUTHORITY AND AREA OF
EXPERTISE.
THE FOLLOWING ITEMS HAVE BEEN IDENTIFIED AS ELEMENTS WHICH NEED TO BE ADDRESS BY
THE APPLICANT:
CITY AND STATE CODE REQUIREMENTS:
Show on the drawing the required perimeter access per Delaware State Fire Prevention
Regulations. Consultation with Fire Marshal can be requested.
Show closest hydrant to proposed buildings on site plan.
Full building and fire plan review is required.
Building cannot be occupied or construction or renovations started until completion of building
and fire plan review.
Sprinkler system required in buildings are over 2500 Sq. Ft. or one hour separation between units
is required.
Project to be completed per approved Site Plan.
RECOMMENDATIONS SUGGESTED AS CONDITIONS OF APPROVAL TO MEET CODE
OBJECTIVES:
ADVISORY COMMENTS TO THE APPLICANT:
Paj 101
Fire Marshal Comments S-13-11
Woodmill Apartments Storage Buildings
May 1, 2013
Page | 2
After any application has been approved by the Planning Commission, the applicant has a
maximum of thirty (30) days to appeal to the Code Board of Appeals Committee.
All comments from this office, approved by the Planning Commission are at the expense of the
owner/applicant.
The proposed building will be reviewed under Mini Storage Occupancy.
The City of Dover uses the 2012 NFPA Life Safety Code, 2009 IBC, latest editions of all other
NFPA Codes and the 2012 Delaware State Fire Prevention Regulations.
The Dover Fire Department request that a 8 ½ X 11 copy of the floor plan and site plan be
submitted to Station 1, attention Fire Chief, prior to the Certificate of Occupancy being issued.
If you have any questions or need to discuss any of the above comments, please call the
above contact person and the Planning Department as soon as possible.
Paj 102
CITY OF DOVER D
E
DEVELOPMENT ADVISORY COMMITTEE
L
APPLICATION REVIEW COMMENTARY D
O
D.A.C. MEETING DATE: October 2, 2013 T
===============================================================
APPLICATION: Woodmill Apartment Storage Buildings and Revised Active
Recreation Area at Woodmill Apartments
FILE#: S-13-19 REVIEWING AGENCY: DelDOT
CONTACT PERSON: Julio F. Seneus PHONE#: 760-2145
===============================================================
THE SUBJECT PROPOSAL HAS BEEN REVIEWED FOR CODE COMPLIANCE, PLAN CONFORMITY AND COMPLETENESS IN
ACCORDANCE WITH THIS AGENCY'S AUTHORITY AND AREA OF EXPERTISE.
THE FOLLOWING ITEMS HAVE BEEN IDENTIFIED AS ELEMENTS WHICH NEED TO BE ADDRESSED BY THE APPLICANT:
CITY & STATE CODE REQUIREMENTS:
The Department has no comments.
RECOMMENDATIONS SUGGESTED AS CONDITIONS OF APPROVAL TO MEET CODE
OBJECTIVES:
ADVISORY COMMENTS TO THE APPLICANT:
If you have any questions or need to discuss any of the above comments, please call the
above contact person and the planning department as soon as possible.
Paj 103
CITY OF DOVER
DEVELOPMENT ADVISORY COMMITTEE
APPLICATION REVIEW COMMENTARY
October 2013
APPLICATION: Woodmill Apartment Storage Buildings
FILE #: S-13-19
REVIEWING AGENCY: Kent Conservation District
CONTACT PERSON: David C. Cahill PHONE #: 741-2600 ext.3
THE SUBJECT PROPOSAL HAS BEEN REVIEWED FOR CODE COMPLIANCE, PLAN CONFORMITY AND COMPLETENESS IN ACCORDANCE WITH
THIS AGENCY’S AUTHORITY AND AREA OF EXPERTISE. THE FOLLOWING ITEMS HAVE BEEN IDENTIFIED AS ELEMENTS WHICH NEED TO BE
ADDRESSED BY THE APPLICANT:
CITY AND STATE CODE REQUIREMENTS:
1. As the disturbance for this site will exceed 5,000 square feet, a detailed sediment and stormwater management plan
must be reviewed and approved by our office prior to any land disturbing activity (i.e. clearing, grubbing, filling,
grading, etc.) taking place. The review fee and a completed Application for a Detailed Plan are due at the time of
plan submittal to our office. Construction inspection fees based on developed area and stormwater facility
maintenance inspection fees based on the number of stormwater facilities are due prior to the start of construction.
Please refer to the fee schedule for those amounts.
2. The following notes must appear on the record plan:
The Kent Conservation District reserves the right to enter private property for purposes of periodic site
inspection.
The Kent Conservation District reserves the right to add, modify, of delete any erosion or sediment
control measure, as it deems necessary.
ADVISORY COMMENTS TO THE APPLICANT:
1. The site may be eligible for a quantity stormwter management waiver. The plans show the removal of the existing
tennis courts; this may reduce the amount of impervious that would be counted toward construction. The site must be
designed for quality requirements.
2. Green Technologies (filter strips, bio swales etc.) must be considered before traditional facilities can be considered.
3. The preferred methods of stormwater management are those practices that maximize the use of the natural features
of a site, promote recharge and minimize the reliance on structural components.
4. It is recommended that the stormwater management areas be incorporated into the overall landscape plan to enhance
water quality and to make the stormwater facility an attractive community amenity.
5. A letter of no objection to recordation will be provided once the detailed Sediment and Stormwater Management
plan has been approved.
Paj 109
City of Dover
DATA SHEET FOR CONCEPTUAL SUBDIVISION PLAN REVIEW
DEVELOPMENT ADVISORY COMMITTEE MEETING OF October 9, 2013
PLANNING COMMISSION MEETING October 21, 2013
Plan Title: Wynsome Oaks
SB-13-05C
Plan Type: Conceptual Subdivision Plan
Applicant/Owner: TLFD Management, LLC
Project Engineer: Kercher Engineering, Inc.
Location: Southeast side of White Oak Road, southwest of Mourning Dove Lane
Tax Parcel: LC-05-068.00-01-18.00-000
Site Area: 12.73 acres ±
Zoning: R-8 (One Family Residence Zone)
SWPOZ (Source Water Protection Overlay Zone)
Tier 2 Primary Wellhead Protection
Present Use: Vacant
Proposed Use: Residential Subdivision – 12 lots, Active Recreation Area, and residual areas
Sanitary Facilities: City of Dover
Water Supply: City of Dover
Waivers Requested: Exceed the Maximum Length of a Dead End Street
Partial Elimination of Sidewalk (along White Oak Road Frontage)
P. O. Box 475 Dover, DE 19903
Community Excellence Through Quality Service
Paj 110
C P
I L
CITY OF DOVER T A
Y N
DEVELOPMENT ADVISORY COMMITTEE N
O I
APPLICATION REVIEW COMMENTARY F N
G
D.A.C. MEETING DATE: October 9, 2013 D
O
V
E
R
APPLICATION: Wynsome Oaks– Conceptual Subdivision Plan
FILE #: SB-13-05C REVIEWING AGENCY: City of Dover Planning Office
CONTACT PERSON: Dawn Melson-Williams, AICP PHONE #: 302-736-7196
PLAN SUMMARY
Conceptual Subdivision Plan Review to permit the subdivision of land totaling 12.73 acres ± into
twelve (12) parcels for single family detached dwellings with a number of areas for open space
and an Active Recreation Area. The property is zoned R-8 (One Family Residence Zone) and is
subject to the SWPOZ (Source Water Protection Overlay Zone). This property is located on the
southeast side of White Oak Road, southwest of Mourning Dove Lane. The owner of record is
TLFD Management, LLC. Tax Parcel: LC-05-068.00-01-18.00-000.
Previous Applications
The Planning Commission reviewed a rezoning application for this property in April 2010 and the
property was rezoned from R-15 (One Family Residence Zone) to R-8 (One Family Residence
Zone) in May 2010. This property was then reviewed for a subdivision as Application SB-10-02C
Wynsome Oaks Subdivision: Conceptual Plan on September 20, 2010; however, that plan has
expired. Application SB-10-02C did receive a one year extension which extended the timeframe to
September 30, 2012 to complete the next step of filing the Preliminary Subdivision Plan; however,
that did not occur and the plan has expired.
Preliminary Land Use Services Review (PLUS)
The Wynsome Oaks Subdivision project was reviewed on February 24, 2010 by the Preliminary
Land Use Services (File #2010-02-01). A PLUS Review comment letter was issued on March
23, 2010. The applicant at the time was required to provide a copy of the written response to the
Office of State Planning Coordination regarding the PLUS Comments. This previous PLUS
Review is still valid as PLUS reviews do not expire. Since the subdivision is the relatively the
same as the one reviewed under PLUS #2010-02-01 then a new PLUS review is not required.
PLUS comments include the comment that the State does not support this subdivision due to its
location east of State Route 1.
SITE CONSIDERATIONS
The minimum lot area for lots within the R-8 (One Family Residence Zone) Zoning District is
8,000 SF. The lots within this proposed subdivision meet or exceed the minimum lot size
requirements. The lots will be 8,000 SF in size or greater. In addition, there are several separate
Paj 111
SB-13-05C Wynsome Oaks Subdivision Conceptual Plan
DAC Report for October 9, 2013
Page 3 of 7
parcels that are devoted to Open Space (woodland areas) and the Active Recreation Area and as
such should be clearly noted on the plan and in the record documents including deeds.
This subdivision of land and any future development on the parcels is subject to the requirements
found in the City of Dover Zoning Ordinance, Article 3 §1 and referenced sections which outline
the permitted uses for the R-8 (One Family Residence Zone). The following table highlights
some of the design standard requirements for the R-8 (One Family Residence Zone). (NOTE:
This chart is not an all-inclusive listing of the code requirements, but is provided as information
on development requirements.)
MINIMUM REQUIRED: R-8 One Family
Residence Zone
Lot Area 8,000 SF
Lot Configuration – width (ft.) 70 ft.
Lot Configuration – depth (ft.) 100 ft.
Front yard setback (ft.) 25 ft.
Residential zone setback (ft.) 10 ft.
Side yard setback (ft.) 20 ft.
Rear yard setback (ft) 30 ft.
Off-Street Parking Spaces 2 per dwelling
Maximum Permitted :
Building Height: Stories 2 ½ stories
1) Feet 35 feet
Lot Coverage 35%
Since this property is zoned R-8 it is subject to the provisions of Zoning Ordinance, Article 5
§1.7 Uniformity of design in all one-family residence zones. These provisions limit construction
of buildings that are like or substantially like a neighboring building in order to prevent
monotony of architectural design.
Wet Soils and Basements
The Zoning Ordinance Article 5 §11.23 regarding wet soils limits the building construction when
seasonally high water table is within two and one-half feet of the surface and requires
construction subject to conditions to address the prevention of water damage. Subdivision plans
must identify the seasonal high water table on each lot if basements are proposed.
Source Water Protection Overlay Zone (SWPOZ)
This property is subject to the requirements of the Source Water Protection Overlay Zone
(SWPOZ) as outlined in Article 3 §29. The proposed subdivision is located within Tier 2
Primary Wellhead Protection. The development of the site as residential is permitted in the
SWPOZ. The additional compliance items in the SWPOZ are related to proximity to the
wellhead; no wellhead locations impact this parcel. There are requirements for stormwater
management within the Tier 2 area (See Article 5 §29.86).
Waiver Request: Partial Elimination of Sidewalk
The plan has indicated sidewalks along both sides of the proposed internal streets. Sidewalk is
also required along the property’s entire frontage of White Oak Road. A written waiver request
to allow for the elimination of sidewalk along White Oak Road has been submitted to the
Planning Office for consideration by the Planning Commission (Letter of September 6, 2013).
Paj 112
SB-13-05C Wynsome Oaks Subdivision Conceptual Plan
DAC Report for October 9, 2013
Page 4 of 7
The request notes limitations to sidewalk construction in this area due to existing utilities (water
main), drainage ditch, and construction limitations.
Streets
The Subdivision Plan proposes one (1) entrance street off of White Oak Road. The proposed
street extends south into the site. A cross street is proposed slightly past half way off of the
proposed entrance street to connect to the adjacent land to the west. The proposed entrance
street will have a paved width of twenty-four (24) feet that will expand to a thirty (30) feet of
paved street width one within the subdivision. The right-of-way for all streets will be a sixty (60)
feet of width. The 30 feet of paved street width will allow for on street parking on one side of
the street. The proposed cross street appears to have 24 feet of paved street width and will not
allow for any on street parking.
Waiver Requested: Length of Dead-end Street
The proposed dead end street is approximately 1033+/- feet in length when measured from White
Oak Road to the center point of the cul-de-sac. The proposed dead end street exceeds the
permitted length of a dead end street per the Land Subdivision Regulations. A portion of this
entrance street (located south of the proposed cross street) that will end in cul-de-sac is 400 feet
in length and would be permitted. However, until the road connection to the west is established
the entire street will be a dead-end street exceeding 400 feet in length. A written waiver request
(Letter of September 6, 2013) has been submitted to the Planning Office for consideration. The
Planning Commission will make a recommendation on this waiver request and to be forwarded
to the appropriate Council Committee and with final action by the Dover City Council.
TREE PLANTING AND LANDSCAPE PLAN
The property is almost entirely wooded. The amount of woodland on the site and the proposed
amount of woodland to be cleared is identified on the plan. The maximum amount of woodland
clearing permitted by Code (without mitigation) to occur is 50%; this project proposes clearing
49.7%. Street tree plantings will be required as a part of the subdivision. Tree plantings for
each individual lot and other tree plantings will be addressed in the Preliminary Subdivision
Plan. Initial calculations indicate ninety-two (92) trees will be required for the project’s non-
woodland area of 275,734.8 SF.
ACTIVE RECREATION AREA
The residential subdivision will also need to provide an Active Recreation Area based on the
number of dwelling units. Based on twelve (12) dwelling units, a total of 3,300 SF of Active
Recreation Area will need to be provided. The applicant has proposed designating a parcel of
21,896 SF for this area. The proposed Active Recreation Area Plan must be received by the
Parks Recreation & Community Enhancement Committee prior to review of a Preliminary
Subdivision Plan.
THE SUBJECT PROPOSAL HAS BEEN REVIEWED FOR CODE COMPLIANCE, PLAN
CONFORMITY, AND COMPLETENESS IN ACCORDANCE WITH THIS AGENCY’S
AUTHORITY AND AREA OF EXPERTISE.
Paj 113
SB-13-05C Wynsome Oaks Subdivision Conceptual Plan
DAC Report for October 9, 2013
Page 5 of 7
CITY AND STATE CODE REQUIREMENTS:
1) Provide a copy of the applicant’s response to the PLUS Review Comment letter of March 23,
2010.
2) A written waiver request to exceed the maximum length of a dead-end street has been
submitted to the Planning Office for consideration by the Planning Commission with final
action by City Council.
3) Sidewalk shall be constructed in accordance to the Zoning Ordinance unless a waiver is
granted by the Planning Commission. A written waiver request for elimination of sidewalk
along White Oak Road has been submitted for consideration by the Planning Commission.
4) Indicate any existing or future easements (drainage, utilities, etc.) on the site.
5) The Site Data and Zoning Schedule will need to be updated with the following:
a) Any changes recommended or approvals or waivers granted by the Planning Commission
and/or City Council.
b) Clarify the number of lots proposed as the number and locations differ within the plan
set. Update plan drawings and data listings.
c) Provide percentage of woodland cleared.
d) Add SWPOZ (Source Water Protection Overlay Zone) as a zoning district.
e) Update General Notes references from Public Utilities to Public Works.
f) Identify source of wetlands information.
6) Sheet 2:
a) The size of the residual parcels must be identified on the Record Plan.
b) Revise the rear setbacks on the plan sheet. The required rear yard setback is 30 feet;
however, the plan shows 20 foot rear yards.
c) Provide a note stating that the remaining woodland areas are not developable lots and that
woodland areas are to remain.
d) Provide a note on the Record Plan identifying the Active Recreation Area parcel and its
use as it will not be a lot for a residential dwelling development.
e) Indicate the maintenance responsibility for the stormwater management areas and
remaining woodland areas.
7) Sheet 3: Identify the location of the existing woodland areas on the property.
8) Sheet 4:
a) Clarify the proposed contour lines shown. It appears that a significant amount of grading
and fill is necessary for the development of the road network and lots for this site.
b) It appears that a drainage easement on the adjacent Bay Village of Dover LLC property
will be necessary to access the Tax Ditch for the stormwater management outfall. Also
ensure appropriate permissions are received for use of the Tax Ditch.
9) Sheet 7:
a) Label paved width of west connection street/cross street.
Paj 114
SB-13-05C Wynsome Oaks Subdivision Conceptual Plan
DAC Report for October 9, 2013
Page 6 of 7
b) A specific side of the street will need to be identified for parking and the opposite side
signed for no parking.
c) Update references to Public Works.
d) Clarify note regarding the roadway patch (floating on the plan drawing).
10) Evaluate the need for a temporary turnaround for west connection street segment. This will
also need to be labeled/signed as a future street connection.
11) If basements are proposed, then the seasonally high water table must be identified for each
lot. Construction is subject to specific requirements. See Zoning Ordinance, Article 5 §11.23.
12) Revise the name of the subdivision and provide names for the streets within the subdivision.
The Kent County GIS Division – 911 Addressing section in conjunction with the City of
Dover, must approve the development name and street names.
RECOMMENDATIONS SUGGESTED AS CONDITIONS OF APPROVAL TO MEET CODE
OBJECTIVES:
1) Recommendation on Waiver Requests:
a) Partial Elimination of Sidewalk: Staff recommends approval of the request to
eliminate sidewalk along the entire frontage of White Oak Road. The applicant has
noted a ditch and utility infrastructure are located in this area and the increase in
impervious surface could further impact the drainage situation in this area. Placement
of the sidewalk on the property and not within the right-of-way would require the loss
of additional woodland and would still impact the ditch.
b) Exceed Maximum Street Length of a Dead End Street: Staff recommends approval of
the request to exceed the maximum length of a dead end street. The subdivision is
proposing a connection to the west and when the connection is made the length of the
dead end street will more closely comply with the limitations of dead-end street
length as required in the Land Subdivision Regulations.
2) Staff is concerned with the level of tree clearing proposed for the development of this site.
The plan proposes that very close to 50% of the existing woodland to be cleared for the
development. Any significant design changes may impact the amount of woodland to be
preserved. It is noted that clearing of woodland areas over 50% requires approval by the
Planning Commission of a Tree Mitigation Plan to re-establish woodland areas.
ADVISORY COMMENTS TO THE APPLICANT:
1) The waivers are at the discretion of the Planning Commission. However, regarding the dead-
end street waiver request, the Planning Commission will provide a recommendation. Such a
waiver request requires a Safety Advisory and Transportation Committee recommendation
and City Council consideration for final approval or denial.
2) Active Recreation Plan submission is the next step in the subdivision process. The Active
Recreation Plan will be reviewed by the Park, Recreation and Community Enhancement
Committee prior to review by the Planning Commission. Contact the Planning Office to
schedule a meeting with Planning Staff to discuss the Active Recreation Area.
Paj 115
SB-13-05C Wynsome Oaks Subdivision Conceptual Plan
DAC Report for October 9, 2013
Page 7 of 7
3) The Conceptual Plan is the first step in the major subdivision process. For this project, the
next step is the submission of the Preliminary Subdivision Plan for review. A Pre-
Application meeting is required to file the Preliminary Subdivision Plan.
4) Other agencies and departments which participate in the Development Advisory Committee
may provide additional comments related to their areas of expertise and code requirements.
5) The developer shall be aware that Street Lights shall be required to be installed in
conjunction with the construction of subdivision streets. The developer shall coordinate
street light placement and electric utility routing and equipment with the City of Dover
Electric Department.
6) In the event, that major changes and revisions to the Conceptual Subdivision Plan occur in
the finalization of the plan contact the Department of Planning and Inspections. These
changes may require resubmittal for review by the Development Advisory Committee,
Planning Commission, or other commissions making recommendations in regards to the
plan.
7) The applicant/developer shall be aware that prior to any ground disturbing activities on the
site the appropriate site inspections and permits are required.
8) Tree protection devices must be installed by the developer prior to any grading or clearing
activity and before the issuance of Building Permits for the site.
9) Construction activities will have an effect on the adjacent property owners and to travel lanes
and/or shoulder area of the adjacent roadway. Any work requiring the closing or rerouting of
potential residents or visitors to adjacent properties should be coordinated as to offer the least
amount of inconvenience to the adjacent property owners and the roadway.
10) The applicant shall be aware that Conceptual Subdivision approval does not represent a
Building Permit, Sign Permit and other associated construction activity permits. A separate
application process is required for issuance of a Permit from the City of Dover.
If you have any questions or need to discuss any of the above comments, please call the
above contact person and the Planning Department as soon as possible.
Paj 116
CITY OF DOVER
DEVELOPMENT ADVISORY COMMITTEE
APPLICATION REVIEW COMMENTARY
STAFF D.A.C. MEETING DATE: OCTOBER 2, 2013
APPLICATION: Wynsome Oaks Subdivision on White Oak Road
FILE #: SB-13-05
REVIEWING AGENCY: City of Dover Electric and Public Works Departments
CONTACT PERSON: Steve Enss - Electric
Jason A. Lyon, P.E. – Public Works
CONTACT PHONE #: Electric - 302-736-7070 Public Works – 302-736-7025
T HE S UBJECT P ROPOSAL HAS BEEN R EVIEWED FOR C ODE C OMPLIANCE , P LAN C ONFORMITY AND C OMPLETENESS IN
A CCORDANCE WITH THIS A GENCY ’ S A UTHORITY AND A REA OF E XPERTISE .
T HE F OLLOWING I TEMS HAVE BEEN I DENTIFIED AS E LEMENTS W HICH N EED TO BE A DDRESSED BY THE A PPLICANT :
CITY AND STATE CODE REQUIREMENTS
ELECTRIC
1. The roadway and curbing must be in.
2. The right-of-way must be within 6" of final grade.
3. The property corners must be staked.
4. Owner is responsible for locating all water, sewer, and storm sewer lines.
5. Owner is responsible for installing all conduits and equipment pads per the City of Dover Engineering Department
specifications.
6. All cable and electrical equipment will be installed along the right-of-way in front of the lots.
7. Owner is responsible for site and/or street lighting.
8. Meter locations will be determined by City of Dover Engineering Department.
9. Load sheets and AutoCAD compatible DXF or DWG diskettes of site plans, including driveways, are required prior to
receiving approved electrical construction drawings.
10. Any relocation of existing electrical equipment will be engineered by the City of Dover Electric Department. Developer
may be required to perform a quantity of the relocation. Any work performed by the City of Dover will be at the
owner’s expense.
11. Prior to construction, owner is responsible for granting an easement to the City of Dover Electric Department.
Easement forms will be furnished and prepared by the City of Dover Electric Engineering Department.
12. Fees will be assessed upon final site plans. The owner will be responsible for fees assessed prior to construction.
Owner is required to sign off plans prepared by the Electric Department.
13. Must maintain 10' clearance around all electrical equipment, unless pre-approved by the City of Dover Electric
Engineering Department.
14. Prior to the completion of any/all designs and estimates, the owner is responsible for providing the Electric
Engineering Department with a physical address of the property.
15. All Engineering and design for Dover Electric will be engineered upon final approved plans. All Engineering work will
be furnished by the City’s Electric Engineering Department.
Paj 117
Wynsome Oaks Subdivision on White Oak Road
File #: SB-13-05
October 2, 2013
Page 2 of 6
WATER
1. All water utility components must meet the requirements of the Water Wastewater Handbook, effective date March 22,
2010. Please contact our office for more information.
2. The following notes must be added to the plans:
a. Hydrant connections by the contractor are prohibited. This method may not be utilized during any phase of the
project.
b. Any existing water lines not to be utilized by the proposed facility must be properly abandoned at the mains in
accordance with the City of Dover Department of Public Works specifications and requirements.
c. The site contractor shall contact the City of Dover Public Works Construction Manager at (302) 736-7025 prior to
the start of construction. A representative from the City of Dover Department of Public Works must observe and
approve all City owned water and sanitary sewer interconnections and testing. All water taps must be performed
by a City of Dover approved contractor. The proposed location for the water connection may need to be adjusted
in the field due to conditions of the existing main. Possible conditions that would require tapping relocation
include proximity to pipe joints, other taps, concrete encasements, conflict with other utilities, and the like. Test
holes must be performed by the contractor to determine the best tapping location. The City of Dover will not be
held responsible for field conditions requiring adjustment of the tapping location or for any work required by the
contractor to make an appropriate and lawful connection.
3. Hydrant connections by the contractor are prohibited. This method may not be utilized during any phase of the
project.
4. The size, type, and location of all proposed and existing water lines and valves must be shown on the plan. All water
mains shall be cement lined Class 52 cement lined ductile iron pipe. Division valves must be provided every 800 feet.
5. Water service lines shall be shown for each residential lot meeting the following requirements: The water services
shall be one-inch (1”) diameter Type K copper tubing, and installed five feet (5’) to the right of the sewer lateral as
viewed from the center line of the street. Curb stops shall be installed one foot (1’) outside of the right-of-way for each
lot. A water meter and meter pit must be installed on the domestic water service, in a non-traffic bearing location just
downstream of the curb stop.
6. Fire hydrants shall be spaced no greater than 600 feet as measured along the curb. Fire hydrants shall be placed
between the curb and sidewalk at intersections or centered on lot lines. Fifteen feet (15’) separation must be provided
between all hydrants and hydrant valves.
WASTEWATER
1. All wastewater utility components must meet the requirements of the Water Wastewater Handbook, effective date
March 22, 2010. Please contact our office for more information.
2. The following notes must be added to the plans:
a. Any existing sanitary sewer lines not to be utilized by the proposed facility must be properly abandoned at the
mains in accordance with the City of Dover Department of Public Works specifications and requirements.
b. Part II, Chapter 180, Article III, Section 180-10 of the Code of Kent County requires that “no person shall
discharge or cause to be discharged any stormwater, surface water, uncontaminated groundwater, roof runoff,
subsurface drainage, uncontaminated noncontact cooling water or unpolluted industrial process waters to any
sanitary sewer”, this shall include condensate. Sec. 110-231 of the City of Dover Code defines storm sewer as
“…any system used for conveying rain water, surface water, condensate, cooling water or similar liquid wastes,
exclusive of sewage.” The contractor, developer, owner and designers shall ensure during construction that no
illegal discharges to the sanitary sewer system are created with the site improvements.
3. All sanitary sewer mains shall terminate at manholes between construction phases. This may require sewer lines to
extend beyond the proposed phase lines to the next manhole.
4. Minimum slope criteria shall meet Ten States Standards. Provide flow calculations to justify sizing of the sewer
mains, showing that velocity requirements are met. Waiver requests must be approved by the Department of Public
Works.
Paj 118
Wynsome Oaks Subdivision on White Oak Road
File #: SB-13-05
October 2, 2013
Page 3 of 6
5. The desired location for sewer mains is under the centerline of the street. One-tenth of a foot (0.1’) drop must be
provided across all manholes. The minimum slope for eight-inch (8”) sanitary sewer pipe is 0.004 feet/feet. Minimum
cover is 3.0 feet.
6. Sanitary sewer manholes shall be spaced no more than 400 feet apart.
7. The minimum size of all sanitary sewer laterals shall be six-inch (6”).
8. The size, length, slope, type and flow directions must be shown on all existing and proposed sanitary sewer lines.
Rim and invert elevations must be labeled on all sanitary structures.
9. Sanitary sewer laterals shall be shown for each residential lot meeting the following requirements: The sewer laterals
shall be six-inch (6”) diameter schedule 35 PVC and, where practicable, installed to the center of each lot. Sewer
laterals shall be connected directly to the main, not manholes, unless impracticable. Sewer laterals are to be installed
one foot (1’) beyond the right-of-way line at a typical depth of three feet (3’), preferably not exceeding five feet (5’).
Cleanouts shall be installed one foot (1’) outside of the right-of-way for each lot.
10. The existing manhole must be core drilled and an approved (by our office) pipe to manhole connector must be used to
construct the connection for installation of the sewer main. The existing manhole flow channel must be reconstructed
accordingly.
STORMWATER
1. Final site plan approval will not be granted until a copy of the approved Stormwater/Erosion and Sediment Control
Plan from Kent Conservation District submitted to our office.
2. The size, length, slope, type and flow directions must be shown on all existing and proposed storm sewer lines. Rim
and invert elevations must be labeled on all stormwater structures.
3. Submerged pipe inlets to ponds may only be permitted if they are so designed that the permanent pool elevation of
the storm water management area doesn’t surcharge back into the City of Dover’s storm drain structures and system.
4. The City of Dover Department of Public Works specifications require all culverts to be designed for the 25-year storm
frequency and all storm sewers to be designed for the 10-year storm frequency. The Manning’s equation shall be
utilized in design as applicable. Storm sewers are required to provide a minimum full flow velocity of 2 fps. Provide
the calculations for each proposed pipe segment that, at a minimum, include: upstream and downstream inverts,
upstream and downstream ground elevations, and ground cover provided; pipe slope, length, material, n value, and
diameter; design flow, depth and velocity; and full flow and velocity.
5. The City of Dover Department of Public Works specifications require that all inlets (catch basins) be designed for the
10-year storm frequency (25-year storm frequency for sump conditions) and that the spread of water shall not exceed
eight feet (8’) from the flow line of the curb. The design must also meet the requirement that the hydraulic grade line
may be no higher than one foot (1’) below the top of the inlet. Provide the calculations for each proposed catch basin
utilizing flows determined by each catch basin’s contributory drainage area, for the appropriate storm frequency.
Spread, depth of flow and hydraulic grade line data for each inlet must also be included. Any carryover should also
be noted and included at appropriate downstream catch basins as applicable.
6. Provide all stormwater management calculations and erosion and sedimentation control plan as required by Article 5,
Section 11.2 and 11.2 of the City of Dover Zoning Ordinance. Ensure that individual lot grading, house locations with
finished floor elevations, and driveway locations and grades are provided on the plans in order to verify the adequacy
of the design. The provided information should also show adequate conveyance of runoff from each lot.
STREETS
1. Final site plan approval will not be granted until a copy of the approved entrance plan, signed by DelDOT is submitted
to our office.
2. The current City of Dover standard street section provides for a 3’ grass strip between the curb and sidewalk. This
standard was administratively revised to meet ADA and FHA compliance with cross slope requirements and to
prevent cars from scrapping at driveways. The revised standard utilizes a five feet (5’) wide public sidewalk with a five
feet (5’) wide grass strip behind the curb.
3. It shall be unlawful for any person to alter the curb of any street so as to create a curb depression for the purpose of
permitting vehicles to enter onto or exit from the city streets, without a permit issued by the city manager.
Paj 119
Wynsome Oaks Subdivision on White Oak Road
File #: SB-13-05
October 2, 2013
Page 4 of 6
4. When determined to be necessary, dead-end streets, designated to be so permanently, shall not be longer than 400
feet and shall be provided at the closed end cul-de-sac with a turnaround having an outside roadway diameter of 80
feet and a street right-of-way diameter of 100 feet. In no instance shall more than 20 percent of the lots in a proposed
development front on the turnaround section of a cul-de-sac.
5. Streets shall be laid out so as to intersect as nearly as possible at right angles. The inner right-of-way line of a street
intersecting another street at an angle of less than 90 degrees shall be tangent to and follow a curve with a minimum
radius of 150 feet centered on the nearest right-of-way line and shall be parallel to said inner right-of-way line.
6. Street right-of-way lines deflecting from each other at any point shall be connected with a curve, the radius of which,
for the centerline of the right-of-way, shall not be less than 500 feet on arterial streets, 300 feet on collector streets
and 150 feet on minor streets. The outer and inner right-of-way line shall be parallel to said center right-of-way line.
7. Street rights-of-way lines at intersections shall be connected with a curve, the radius of which shall be at least 25 feet.
The required radius may be increased by the city engineer if the increased radius is necessary for public safety.
8. Street grades shall not exceed five percent.
9. Street grades shall not be less than one-half percent wherever feasible.
SANITATION
1. Every person occupying a residence or duplex and every owner of an apartment shall provide such premises with a
sufficient number of solid waste containers to provide adequate capacity for the solid waste placed out for collection
without overloading the capacity of the containers.
GROUNDS
1. An official street tree species list has been approved by the superintendent of grounds for tree plantings along streets
and avenues of the city. (The official list will be kept on file in the office of the city clerk.) No species other than those
included in this list may be planted as street trees without the written permission of the superintendent of grounds.
2. Spacing of trees shall be determined by the superintendent of grounds, but, generally, all large trees shall be planted
no closer than 35 feet, medium trees no closer than 30 feet and small trees no closer than 25 feet, except in special
plantings designed or approved by a landscape architect.
3. No street tree shall be planted closer than 30 feet to any street corner and no closer than ten feet to any fireplug.
4. Only trees listed as small to medium shall be planted under power lines; and no trees shall be planted within ten feet
of any underground water line, sewer line, transmission line or other utility.
5. It shall be unlawful and a nuisance for any person to plant any vegetation in any public right-of-way. Upon receipt of
notice from the city to remove any vegetation located in a public right-of-way, the owner of the abutting property shall
remove such vegetation at his own expense within the time limit provided in such notice.
6. It shall be unlawful and a nuisance for any person to plant any tree, shrub or bush within 16 feet of the curbline. Upon
receipt of notice from the city to remove any tree, shrub or bush which is located within 16 feet of the curbline, the
owner of the property upon which such tree, shrub or bush is located shall remove the same at his own expense
within the time limit fixed in such notice.
GENERAL
1. Add the following note to the plans, “A seven and one half feet (7.5’) wide easement is retained along all side and rear
lot lines, to be unoccupied by building, for utilities, drainage and sanitary sewer purposes. Except where lots are
divided for any reason whatsoever, said easements shall fall along the actual side and rear lot lines as conveyed. A
fifteen feet (15’) wide utility easement is retained along all rear lines of lots abutting the project boundary and other
open spaces.” A ten feet (10’) wide utility easement is required along all front yard lot lines for utility installation.
When a water, sewer, or storm sewer main is not located in the right of way, it shall be located within five feet (5’) of
the center of a twenty feet (20’) wide utility easement.
2. The final site plan must be submitted in the following compatible digital formats:
a. AutoCAD 2004 (.dwg format).
b. Adobe Reader (.pdf format).
Paj 120
Wynsome Oaks Subdivision on White Oak Road
File #: SB-13-05
October 2, 2013
Page 5 of 6
3. All existing utilities shall be adjusted to final grade in accordance with current City of Dover requirements and
practices. This must be included as a note on the plan.
4. No trees shall be planted within the vicinity (10 feet) of any underground utilities (electric, water, sanitary sewer, storm
sewer, etc.). All street trees shall be planted on private property.
RECOMMENDATIONS SUGGESTED AS CONDITIONS OF APPROVAL TO MEET CODE OBJECTIVES
ELECTRIC
1. Owner must give the City of Dover Electric Department three (3) months notice prior to construction. Owner is
responsible for following the requirements outlined in the City of Dover’s Electric Service Handbook. The handbook is
now available on the website at the following link:
http://www.cityofdover.com/media/documents/2010%20Electric%20Service%20Handbook.pdf
WATER / WASTEWATER / STREETS / SANITATION / GROUNDS / GENERAL
1. None.
STORMWATER
1. Profiles of the storm sewer must be provided with the construction plans. All water, sanitary sewer and storm sewer
crossings must be shown on the profiles.
2. This site currently contains various drainage issues. In the event basements are to be provided as part of the
proposed subdivision, consideration for the flow from sump pumps and other associated facilities, including
calculations, are to be submitted to our office for our review. This is to ensure that the overall drainage plan for the
site is adequate in accordance that noted previously.
ADVISORY COMMENTS TO THE APPLICANT
ELECTRIC
1. None.
WATER
1. The City of Dover water system is available to this site. The developer is responsible for all costs associated with
extending and providing service to the proposed development.
2. Prior to plan approval, the water system plans must be submitted to the Division of Public Health, Office of Drinking
Water for review and approval. The owner/developer will be responsible for providing all completed forms and plan
sets to the City of Dover as required for submission to the Office of Drinking Water. Plans will not be submitted to the
Office of Drinking Water until review has been completed by our office.
3. Hydrant flow testing is currently only performed two (2) times per year during system wide flushing operations. The
applicant must call the Department of Public Works directly to schedule these tests. This applies to both existing
hydrants as well as those proposed for the site.
WASTEWATER
1. The City of Dover sanitary sewer system is available to this site. The developer is responsible for all costs associated
with extending and providing service and capacity to the proposed development.
2. Prior to plan approval, the sanitary sewer system plans must be submitted to the DNREC, Division of Water
Resources, Surface Water Discharges Section for review and approval. The owner/developer is responsible for
providing all application fees, completed forms and plan sets directly to DNREC.
3. Profiles of the sanitary sewer main must be provided with the construction plans. All water, sanitary sewer and storm
sewer crossings must be shown on the profiles.
4. A sanitary sewer stub is also available through the Oak Shadows subdivision to the east. Analysis of the most
prudent connection location should be included as part of the subdivision design. Utility dedication of this subdivision
is currently pending.
Paj 121
Wynsome Oaks Subdivision on White Oak Road
File #: SB-13-05
October 2, 2013
Page 6 of 6
STORMWATER
1. Profiles of the storm sewer must be provided with the construction plans. All water, sanitary sewer and storm sewer
crossings must be shown on the profiles.
STREETS
1. Street profiles must be provided with the construction plans.
2. All streets to be dedicated to the City must meet the City of Dover Department of Public Works specifications.
a. Pavement sections must be designed based upon poor soil conditions unless soil boring data is provided showing
otherwise. Structural number calculations must be submitted for review and a pavement cross section detail
must be included within the plan set.
b. All curbing within the right-of-way shall be DelDOT Type III curb and gutter. All curb radii must be labeled on the
plan. In particular, a minimum radius of twenty-five feet (25’) must be provided at all street intersections. A
construction detail of the Type III curb and gutter must be provided on the plan.
c. Sidewalk proposed within the right-of-way shall be constructed as per the City of Dover Standards and
Specifications. All sidewalks must be poured by hand; curb machine slip formed sidewalks will not be permitted.
The sidewalk must be scored in five feet (5’) squares using hand tooled joints. All tool marks shall be removed as
tool finished edges are not permitted. Expansion joints shall be installed at a spacing of twenty feet (20’) and
shall be precut, one-half inch (½ “) thick, four-inch (4”) wide, cork sheets. All sidewalk proposed within the right-
of-way shall consist of Class B concrete, without reinforcing material, in order to prevent future interference with
utility locating. The proposed five feet (5’) wide public sidewalk shall be installed 5 feet from the back of curb.
The sidewalk cross slope shall not exceed 2% including across the driveways to ensure ADA and FHA
compliance. A sidewalk construction detail containing the above information must be provided on the plan.
d. All barrier free access ramps and driveway aprons constructed with the site improvements shall be in accordance
with the most current ADA and DelDOT requirements and standards at the time of construction. To meet cross
slope requirements a five feet (5’) wide grass strip must be provided between a five feet (5’) sidewalk and the
curb.
e. Signage and markings must be included with the site plan in accordance the Manual for Uniform Traffic Control
Devices. Signage proposed for streets to be dedicated to the City of Dover must be included on the plan (no
parking signs, speed limit signs, street blades, stops signs, watch children, etc.) All signs must be installed on
two-inch (2”) square break away sign posts.
SANITATION / GROUNDS
1. None
GENERAL
1. Provide a materials listing table for proposed water mains and services, proposed sanitary sewer mains and services,
and proposed storm sewer. A table listing all infrastructure elements to be dedicated to the City of Dover must also
be provided on the plans.
2. Construction plans will not be reviewed by our office unless all previous comments have been clearly addressed
within the plan set and accordingly identified within an itemized response letter and with the Water/Wastewater Initial
Plan Submission Checklist, which can be obtained from the following website: https://imageserv9.team-
logic.com/mediaLibrary/198/WaterWastewaterHandbookFinal_1.pdf, page 88.
I F Y OU H AVE A NY Q UESTIONS OR N EED TO D ISCUSS ANY OF THE A BOVE C OMMENTS , P LEASE C ALL THE A BOVE
C ONTACT P ERSON AND THE P LANNING D EPARTMENT AS S OON AS P OSSIBLE .
Paj 122
C F
I I
CITY OF DOVER T R
Y E
DEVELOPMENT ADVISORY COMMITTEE
O M
APPLICATION REVIEW COMMENTARY F A
R
D.A.C. MEETING DATE: D S
O H
V A
E L
R
APPLICATION: Wynsome Oaks Subdivision_
FILE #: SB-13-05 REVIEWING AGENCY: City of Dover, Office of the Fire Marshal
CONTACT PERSON: David Truax, Fire Marshal PHONE #: (302) 736-7011
THE SUBJECT PROPOSAL HAS BEEN REVIEWED FOR CODE COMPLIANCE, PLAN CONFORMITY,
AND COMPLETENESS IN ACCORDANCE WITH THIS AGENCY’S AUTHORITY AND AREA OF
EXPERTISE.
THE FOLLOWING ITEMS HAVE BEEN IDENTIFIED AS ELEMENTS WHICH NEED TO BE ADDRESS BY
THE APPLICANT:
CITY AND STATE CODE REQUIREMENTS:
1. During construction, every building shall be accessible to Fire Department apparatus by
way of access roadways with all-weather driving surface of not less than 20 feet of
unobstructed width to withstand the live loads of fire apparatus and having a minimum of
13 feet 6 inch vertical clearance. Dead-end Fire Department access roads in excess of
150 feet in length shall be provided with approved provisions for the turning around of
Fire Department apparatus.
2. Water supply for fire protection either temporary or permanent shall be made available as
soon as combustible material accumulates. There shall be no delay in the installation of
fire protection equipment. Where underground water mains and hydrants are to be
provided, they shall be installed, completed and in service prior to the construction work.
3. Building permits will not be issued until the area has been inspected for the condition of
the roadway and fire protection water is available.
4. Any gas fired HVAC equipment must be equipped with emergency cut off switches
remotely located.
5. Address numbers of at least 4 inches in height must be placed on the street side of each
Residence.
Paj 123
DAC REPORT
Page 2
Wynsome Oaks
6. Plan to be submitted showing the location of fire hydrants. Hydrants are to be 600 feet
on center. This is to be measured as hose would come off of fire equipment. Hydrants
are to be located within 300 feet of Fire Department connections for buildings with
sprinklers.
7. Drive lanes of roadways not to be less than 24 feet wide. If roadways are to be used as
fire lanes, they must be 24 feet wide for primary access.
RECOMMENDATIONS SUGGESTED AS CONDITIONS OF APPROVAL TO MEET CODE
OBJECTIVES:
NONE
ADVISORY COMMENTS TO THE APPLICANT:
1. After any application has been approved by the Planning Commission, the applicant has a
maximum of thirty (30) days t appeal to the Code Board of Appeals Committee.
2. All comments from this office, approved by the Planning Commission are at the expense
of the owner/applicant.
3. The City of Dover uses the 2003 NFPA Life Safety Code, 2003 IBC, latest editions of all
other NFPA Codes and the 2006 Delaware State Fire Prevention Regulations.
4. Legislation to sprinkler Townhouses will be before the Safety and Transportation
Committee in February of 2007. You may wish to make plans should this pass.
If you have any questions or need to discuss any of the above comments, please call the
above contact person and the Planning Department as soon as possible.
Paj 124
CITY OF DOVER D
E
DEVELOPMENT ADVISORY COMMITTEE
L
APPLICATION REVIEW COMMENTARY D
O
D.A.C. MEETING DATE: October 2, 2013 T
===============================================================
APPLICATION: Wynsome Oak Subdivision on White Oak Road
FILE#: SB-13-05 REVIEWING AGENCY: DelDOT
CONTACT PERSON: Julio F. Seneus PHONE#: 760-2145
===============================================================
THE SUBJECT PROPOSAL HAS BEEN REVIEWED FOR CODE COMPLIANCE, PLAN CONFORMITY AND COMPLETENESS IN
ACCORDANCE WITH THIS AGENCY'S AUTHORITY AND AREA OF EXPERTISE.
THE FOLLOWING ITEMS HAVE BEEN IDENTIFIED AS ELEMENTS WHICH NEED TO BE ADDRESSED BY THE APPLICANT:
CITY & STATE CODE REQUIREMENTS:
1. Per Section 3.6.5 of the Standards and Regulations for Subdivision Streets and State
Highway Access Adopted February 15, 2010, a 60-foot wide right-of-way (30-feet from
the centerline) is required for a minor arterial. According to the Kent County
Classification Maps, KCR 66 (White Oak Road) is classified as a local road. If the
existing right-of-way does not have the proper width along the frontage of the site, the
department will require the right-of-way dedication for public use.
2. In order to be issued a Letter of No Objection (LONO), the department will require the
applicant to provide the proper forms, fees, and plans.
3. An additional 15-foot permanent easement will be warranted along the site frontage of
this project.
RECOMMENDATIONS SUGGESTED AS CONDITIONS OF APPROVAL TO MEET CODE
OBJECTIVES:
ADVISORY COMMENTS TO THE APPLICANT:
A stormwater manager report must be provided to the Department for review and
approval.
If you have any questions or need to discuss any of the above comments, please call the
above contact person and the planning department as soon as possible.
Paj 125
CITY OF DOVER
DEVELOPMENT ADVISORY COMMITTEE
APPLICATION REVIEW COMMENTARY
October 2013
APPLICATION: Wynsome Oaks Subdivision
FILE #: SB-13-05
REVIEWING AGENCY: Kent Conservation District
CONTACT PERSON: David C. Cahill PHONE #: 741-2600 ext.3
THE SUBJECT PROPOSAL HAS BEEN REVIEWED FOR CODE COMPLIANCE, PLAN
CONFORMITY AND COMPLETENESS IN ACCORDANCE WITH THIS AGENCY’S AUTHORITY
AND AREA OF EXPERTISE. THE FOLLOWING ITEMS HAVE BEEN IDENTIFIED AS ELEMENTS
WHICH NEED TO BE ADDRESSED BY THE APPLICANT:
CITY AND STATE CODE REQUIREMENTS:
1. Kent Conservation District has no objection to the subdivision of the above referenced site.
ADVISORY COMMENTS TO THE APPLICANT:
The Following comments are advisory and apply to the development of a detailed site plan for this project.
A detailed Sediment and Stormwater Management Plan must be approved by our office prior to any land
disturbing activity (i.e. clearing, grading, filling, etc.) over 5000 square feet.
Paj 126
Kent County
Department of Planning Services
Division of Geographic Information Systems
SARAH E. KEIFER, AICP Phone: 302/744-2420
Director of Planning Services FAX: 302/736-2128
Email: sabrina.fite@co.kent.de.us
SABRINA FITE
GIS Specialist
TO: - Dawn E. Melson-Williams, AICP
The City of Dover
- Kercher Engineering, Inc.
FROM: Sabrina Fite
911 Addressing
DATE: September 20, 2013
PIN #: 4-05-068.00-01-18.00-000
OWNER: TLFD Management, LLC
REF: SB-13-05 Wynsome Oaks
- As noted in comments for the prior application SB-10-02, Kent County does not approve the
subdivision name “WYNSOME OAKS”
Paj 127
CITY OF DOVER Dover/Kent
County
DEVELOPMENT ADVISORY COMMITTEE
Metropolitan
APPLICATION REVIEW COMMENTARY Planning
Organization
D.A.C. MEETING DATE: 10/9/13
APPLICATION: Wynsome Oaks Subdivision
FILE #: SB-13-05 REVIEWING AGENCY: Dover/Kent County
MPO
CONTACT PERSON: James Galvin, AICP PHONE #: (302) 387-6030
The Dover/Kent County MPO has participated in the State’s Preliminary Land Use Services (PLUS) process for several
months. The MPO requested the opportunity to bring the recommendations on issues of our concern to the City as well. The
MPO will limit comments to projects to development proposals and applications that may lead to new development. Issues
of concern to the MPO are effective transit, reducing the amount of vehicle emissions by shortening or eliminating trips, and
facilities for alternative modes of transportation, including bicycle and pedestrian access. The MPO considers the bicycle
facilities required by the City of Dover to be the standard for all applications, not to be waived.
City of Dover Planning Commission 10/21/2013
Project Review
SB-13-05 Wynsome Oaks Subdivision on White Oak Road
The MPO has no comment on the subdivision itself. There are some elements of the proposal that we will take
the opportunity to comment on.
The plans indicate sidewalks on the interior of the site. The MPO encourages sidewalks that allow a safe
connection with a sidewalk network. The mechanism for these improvements has been to require the sidewalks
be installed on the Road ROW as the adjacent properties are developed. While the sidewalk may not be
continuous at present, the cumulative effect of the property owners’ installation will ultimately be a complete
sidewalk system. Thus the City should uphold the requirement for all of the sidewalks on the site, including
those at the entrance.
This is the last of three proposals that are at some development stage and considered by the Dover Planning
Commission; the previously approved Garrison Oak and Bay Village sites. The win some Oaks site has been
previously reviewed by the planning commission it in September 2010. Included in the combined proposals are
nearly 450 residential units and room for 10 more employers. The density of activity should be considered a
potential transit node for DART bus service. The 108 bus route currently extends on White Oak Road to Willis
Road. The applicant should coordinate with the other applicants to bring bus service to the area at the discretion
of the Delaware Transit Corporation.
If you have any questions or need to discuss any of the above comments, please call the above
contact person and the Planning Department as soon as possible.
Paj 130
STATE OF DELAWARE
EXECUTIVE DEPARTMENT
OFFICE OF STATE PLANNING COORDINATION
March 23, 2010
Mr. Jeffrey C. Williams
Kercher Engineering
254 Chapman Road, Ste. 202
Newark, DE 19702
RE: PLUS review – 2010-02-01; White Oak Road Subdivision
Dear Mr. Williams:
Thank you for meeting with State agency planners on March 24, 2010 to discuss the proposed
plans for the White Oak Road Subdivision to be located on the south side of White Oak Road,
1340 ft. west of Long Point Road, within the City of Dover.
According to the information received, you are seeking a rezoning of 12.78 acres from R-20 to
R-8 for 17 single family homes.
Please note that changes to the plan, other than those suggested in this letter, could result in
additional comments from the State. Additionally, these comments reflect only issues that are
the responsibility of the agencies represented at the meeting. The developers will also need to
comply with any Federal, State and local regulations regarding this property. We also note
that as the City of Dover is the governing authority over this land, the developers will need
to comply with any and all regulations/restrictions set forth by the County.
Strategies for State Policies and Spending
This project is located within a Level 2 and Level 3 according to the Strategies for State Policies
and Spending and within the City of Dover. Investment Level 2 and 3 generally reflect areas
where growth is anticipated by local, county, and State plans in the near to long term future.
However, the project’s location East of Route 1 is a particular concern. It is the State’s policy to
discourage new growth East of State Route 1. Starting with the historic Coastal Zone Act, State
actions have encouraged natural resource and agricultural preservation rather than growth and
development in this area of Kent County.
122 William Penn Street ⋅ Third Floor ⋅ Dover, DE 19901
Phone (302)739‐3090 ⋅ Fax (302) 739‐6958 ⋅ www. stateplanning.delaware.gov
Paj 131
PLUS 2010-02-01
Page 2 of 10
When the State purchased the Garrison Oak tract for the City for the development of an
employment center, it came with the understanding that the development of the tract would not
encourage or enable further development East of Route 1. In the intervening years the State has
modified this position by supporting the development of Evergreen Acres (PLUS 2009-06-03) as
a unique opportunity for workforce housing tied to the development of the Garrison Oak
Technology Park. In our letter about that project, dated July 22, 2009, we conditioned our
support by stipulating that “There is a clear understanding by all parties that this development is
a special circumstance which addresses both economic development and land conservation
objectives, and does not in any way represent a policy shift which would allow or encourage
other land developments E. of Route 1.”
The proposed White Oak Road Subdivision will require a rezoning from R20 to R8, representing
an increase in residential density. The current zoning designation is consistent with Dover’s
certified comprehensive plan and is more in keeping with our longstanding policy of
encouraging land preservation and conservation activities East of Route 1. The State does not
support the rezoning of this parcel for these reasons.
Code Requirements/Agency Permitting Requirements
• It is important that the developer be aware of the Delaware Unmarked Human Remains
Act of 1987, outlined in Chapter 54 of Title 7 of the Delaware Code, which pertains to
the discovery and disposition of such remains. The unexpected discovery of unmarked
human remains during construction can result in significant delays while the process is
carried out.
• Sediment and Stormwater Program. A detailed sediment and stormwater plan will be
required prior to any land disturbing activity taking place on the site. It is strongly
recommended that the owner and consultant contact the Kent Conservation District to
schedule a project application meeting to discuss the sediment and erosion control and
stormwater management components of the plan. The site topography, soils mapping,
pre- and post-development runoff, and proposed method(s) and location(s) of stormwater
management should be brought to the meeting for discussion. The plan review and
approval as well as construction inspection will be coordinated through the Kent
Conservation District. Contact Jared Adkins, Program Manager, at the Kent Conservation
District at (302) 741-2600, ext. 3 for details regarding submittal requirements and fees.
The property does not appear to extend to the tax ditch. Please discuss the proposed use
of Prong B of the White Oak Tax Ditch as an outlet for the stormwater on this site at the
project application meeting.
• TMDLs. Total Maximum Daily Loads (TMDLs) for nitrogen and phosphorus have been
promulgated through regulation for the Leipsic River watershed. A TMDL is the
maximum level of pollution allowed for a given pollutant below which a “water quality
limited water body” can assimilate and still meet water quality standards to the extent
necessary to support use goals such as, swimming, fishing, drinking water and shell fish
Paj 132
PLUS 2010-02-01
Page 3 of 10
harvesting. Although TMDLs are required by federal law, states are charged with
developing and implementing standards to support these desired use goals. In the Leipsic
River watershed, “target-rate-nutrient reductions” of 40 percent will be required for
nitrogen and phosphorus. Additionally, “target-rate-reductions” of 75 percent will be
required for bacteria. More on TMDLs is included in the “Recommendations” category.
• Should dewatering points be needed during any phase of construction, a dewatering well
construction permit must be obtained from the Water Supply Section prior to construction
of the well points. In addition, a water allocation permit will be needed if the pumping
rate will exceed 50,000 gallons per day at any time during operation.
• All well permit applications must be prepared and signed by licensed water well
contractors, and only licensed well drillers may construct the wells. Please factor in the
necessary time for processing the well permit applications into the construction schedule.
Dewatering well permit applications typically take approximately four weeks to process,
which allows the necessary time for technical review and advertising. Ricardo Rios -
(302) 739-9944, Ricardo.Rios@state.de.us
Recommendations/Additional Information
This section includes a list of site specific suggestions that are intended to enhance the project.
These suggestions have been generated by the State Agencies based on their expertise and
subject area knowledge. These suggestions do not represent State code requirements.
They are offered here in order to provide proactive ideas to help the applicant enhance the site
design, and it is hoped (but in no way required) that the applicant will open a dialogue with the
relevant agencies to discuss how these suggestions can benefit the project.
Department of Agriculture
• Right Tree for the Right Place
The Delaware Department of Agriculture Forest Service encourages the developer to use
the “Right Tree for the Right Place” for any design considerations. This concept allows
for the proper placement of trees to increase property values in upwards of 25% of
appraised value and will reduce heating and cooling costs on average by 20 to 35 dollars
per month. In addition, a landscape design that encompasses this approach will avoid
future maintenance cost to the property owner and ensure a lasting forest resource.
Paj 133
PLUS 2010-02-01
Page 4 of 10
• Do Not Plant List: Due to the high risk of mortality from insects and disease, the
Delaware Forest Service does not recommend planting any of the following species:
Callery Pear
Leyland Cypress
Red Oak (except for Willow Oak)
Ash Trees
Please contact the Delaware Forest Service for more information at (302) 698-4500.
State Historic Preservation Office
• According to observations and evaluation, there are no known historic or cultural
resources in this project area, such as archaeological sites or National Register-Listed
property on or near this proposed project site.
• However, since Delaware has a strong agricultural and rural heritage, there is a
possibility that could be a historic-period or prehistoric-period archaeological site
historically associated with Delaware’s agricultural or rural heritage, which have not been
found, but may contain important information about Delaware’s history.
• Prior to any demolition or ground-disturbing activities, the developer may want to
consider hiring an archaeological consultant to examine the
parcel for archaeological sites, including a cemetery or unmarked human remains. If you
have any questions or concerns, please contact Terence Burns at 302-736-7404.
DelDOT
• DelDOT recognizes that that the internal streets would be City streets and therefore
outside their jurisdiction. Nonetheless, they offer the following advisory comments
regarding them. The proposed stub street leading to the Bay Village of Dover property is
laudable, but it may not be in the best place. There is an existing stub street in the
adjoining Oak Shadows subdivision that aligns with Lot 5 and the proposed stub street.
If the subject development can only be connected to Oak Shadows or Bay Village,
DelDOT would recommend that the connection be made to Oak Shadows because the
stub exists and the connection can be made now. By comparison, there is no approved
plan for Bay Village of Dover and no definite date for its construction. If possible, the
subject development should be connected to both Oak Shadows and Bay Village of
Dover and the stub street to Bay Village should be shifted south, perhaps to the cul-de-
sac bulb, so as to discourage through traffic between Oak Shadows and Bay Village.
• If the rezoning is approved, DelDOT recommends that the developer have their engineer
contact the DelDOT Subdivision Manager for the north part of Kent County, Mr. Julio
Seneus, for more detailed comments on the site plan as they develop it further. Mr.
Seneus may be reached at (302) 760-2145.
Paj 134
PLUS 2010-02-01
Page 5 of 10
DNREC
Fish and Wildlife - Please contact Edna Stetzar at (302) 653-2880 ext. 101 or at
Edna.Stetzar@state.de.us
• Site Survey Request. The forest on the project parcel is potentially more than 70 years
of age, which may be late successional to early mature depending on the composition of
the plant community and development of the understory. According to 1937 aerial
imagery the forest was in a stage of young growth at that time. Our community ecologist
is interested in mapping the vegetation communities at this site as part of a state-wide
effort to evaluate forest communities and map wildlife habitat. The survey would be
conducted at no expense to the landowner. A report of the survey and vegetative
community map would be generated for the applicant’s use in the planning of this
project. If unique vegetative communities are observed during the survey,
recommendations to reduce impacts will be offered for consideration. Please contact
Edna Stetzar if the landowner will grant a site visit.
Recommendations:
• It is important to maintain connections between areas of habitat across the landscape.
These areas provide cover and space for wildlife to travel during daily, seasonal, and
migratory activities. This project is basically surrounded by parcels also being
considered for development. Open space that occurs in small disconnected areas next to
lots or that occurs as a narrow strip between developments is not as useful to wildlife as
those areas of open space that are larger and connect to other undeveloped areas of open
space. We recommend the applicant consider coordinating with adjacent landowners so
that habitat connections can be maximized. DNREC further recommends that open
space be permanently preserved so that future clearing is less likely.
• Stormwater management methods that do not require tree removal should also be
discussed with the district engineer or stormwater approval agency to determine if
implementing them is feasible at this site.
• Clearing should not occur between April 1st and July 31st to reduce impacts to birds and
other wildlife that utilize forested areas for breeding. This recommendation would only
minimize impacts to those species during one breeding season, because once trees are
cleared the habitat will be lost to use by those species.
• DNREC recommends native plantings, including tall grasses, wildflowers, shrubs, and
trees at the edge and within an adequate buffer (15-30 feet in width) around the ponds to
discourage nuisance waterfowl such as geese (to be planted in accordance with the
Sediment and Stormwater Plan approval agency requirements). When the view of the
surrounding area from the pond is blocked, geese can’t scan for predators and are less
likely to reside and nest in the area of the pond.
Paj 135
PLUS 2010-02-01
Page 6 of 10
• At this time, DNREC does not recommend using monofilament grids due to the potential
for birds and other wildlife to become entangled if the grids are not properly installed and
maintained. In addition, the on-going maintenance (removing entangled trash, etc.) may
become a burden to the homeowners association or land manager.
Soil and Water - Please contact James Sullivan at (302) 739-9921 or
James.Sullivan@state.de.us
• Drainage Program. Existing woodland provides valuable wildlife habitat as well as soil
erosion protection, water quality filtering, and surface water uptake. Unless managed for
timber, wooded areas typically were areas that were unprofitable for farming due to poor
drainage. Without trees to absorb the surface water these areas tend to require intensive
drainage. Over the years there have been many drainage concerns with the adjacent
subdivision that have not been able to be resolved. There is the strong potential for this
site to experience drainage problems.
• The Drainage Program requests that the engineer take precautions to ensure the project
does not hinder any off site drainage upstream of the project or create any off site
drainage problems downstream by the release of onsite storm water. The Drainage
Program requests that the engineer check existing downstream ditches and pipes for
function and blockages prior to the construction. Notify downstream landowners of the
change in volume of water released on them.
• Have all drainage easements recorded on deeds and place restrictions on obstructions
within the easements to ensure access for periodic maintenance or future re-construction.
Future property owners may not be aware of a drainage easement on their property if the
easement is only on the record plan. However, by recording the drainage easement on the
deed, the second owner, and any subsequent owner of the property, will be fully aware of
the drainage easement on their property.
• The Drainage Program does not support the removal of trees for the creation of
stormwater management areas. However, the Drainage Program does recognize that tree
removal is unavoidable in some cases. Where practical, plant native trees and shrubs to
compensate for the loss of nutrient uptake and stormwater absorption the removed trees
provided.
Paj 136
PLUS 2010-02-01
Page 7 of 10
Water Resources - Please contact John Martin at (302) 739-9939 or John.Martin@state.de.us
• Soils Assessment. Tent is a poorly-drained wetland associated (hydric) soil with severe
limitations for development; these soils are considered unsuitable for development and
should be avoided (Figure 1).
Figure 1: NRCS soil
survey update
mapping in the
vicinity of the
proposed White
Oak Road
subdivision
• Studies have shown a strong relationship between increases in impervious cover to
decreases in a watershed’s overall water quality. It is strongly recommended that the
applicant implement best management practices (BMPs) that reduce or mitigate some of
its most likely adverse impacts. Reducing the amount of surface imperviousness
through the use of pervious paving materials (“pervious pavers”) in lieu of asphalt or
concrete in conjunction with an increase in forest cover preservation or additional tree
plantings are some examples of practical BMPs that could easily be implemented to help
reduce surface imperviousness.
• TMDLs. The Pollution Control Strategy for the Leipsic watershed has not been formally
completed to date. In the absence of a PCS during the intervening time period, the
applicant is strongly encouraged to reduce nutrient and bacterial pollutants to help
improve water quality through voluntary commitment to the implementation of the
following recommended BMPs:
1) Maintaining 100-foot buffers from all delineated wetlands (State and federally-
regulated wetlands
2) Maximizing the amount of passive wooded open space (i.e., significantly reducing
the amount of forest cover removal)
Paj 137
PLUS 2010-02-01
Page 8 of 10
3) Employ the use of pervious paving materials instead of asphalt or concrete to reduce
surface imperviousness, wherever practicable
4) Utilize green-technology stormwater management technologies in lieu of open-water
stormwater management structures
The Department has also developed an assessment tool to evaluate how your proposed
development may reduce nutrients and bacteria to help meet the TMDL requirements.
Please contact Lyle Jones at 302-739-9939 for more information on the assessment tool.
• Water Resource Protection Areas. DNREC Water Supply Section, Ground-Water
Protection Branch (GPB) has determined that it falls entirely within a wellhead protection
area for the City of Dover as delineated by DNREC. Although the City of Dover’s
Source Water Protection Ordinance meets the minimum standards of protection, this
protection does not extend over all the scientifically delineated wellhead areas. This
project is located in one of these areas.
• Given that this is a wellhead protection area, the
City is strongly encouraged to apply impervious
cover limitations on this development. The
Developer states that the impervious cover for
this project is approximately 19.3%. Impervious
cover prevents precipitation from infiltrating
through the soil to the water table aquifer.
Impervious cover refers to structures including
but not limited to roads, sidewalks, parking lots,
and buildings. Any impervious cover within this
wellhead protection area has the potential to have
a negative effect on the quality and quantity of
drinking water available to the City.
• The DNREC Water Supply Section recommends
that the portion of the new development within
the scientifically delineated wellhead protection area not exceed 20% impervious cover
(DNREC, 2005). Some allowance for augmenting ground-water recharge should be
implemented if the impervious cover exceeds 20% but is less than 50%. However, the
development should not exceed 50%. A water balance calculation should be required to
determine the quantity of clean water recharged via a recharge basin (Kaufmann, 2005).
The purpose of an impervious cover threshold is to minimize loss of recharge (and
associated increases in storm water) and protect the quality and quantity of ground water
and surface water supplies.
Paj 138
PLUS 2010-02-01
Page 9 of 10
• In addition, because the project is located within a wellhead protection area and the
wellhead is a source of public drinking water, the storage of hazardous substances or
wastes should not be allowed within the area unless specific approval is obtained from
the relevant state, federal, or local program.
Air and Waste Management – Please contact Deanna Morozowich at (302) 739-9402 or
Deanna.morozowich@state.de.us
• Hazardous Waste Sites. Based on the close proximity of the salvage yard and the
previous agricultural use of the proposed project site, which may have involved the use of
pesticides and herbicides, SIRB recommends that a Phase I Environmental Site
Assessment be performed prior to development. DNREC's Site Investigation and
Restoration Branch (SIRB) has reviewed the proposed project. No SIRB sites were found
within a ½-mile radius of the proposed development. One salvage yard, White Oak
Salvage, is located 63 feet west of the proposed site. In addition, should a release or
imminent threat of a release of hazardous substances be discovered during the course of
development (e.g., contaminated water or soil), construction activities should be
discontinued immediately and DNREC should be notified at the 24-hour emergency
number (800-662-8802). SIRB should also be contacted as soon as possible at 302-395-
2600 for further instructions. Krystal Stanley - (302) 395-2644,
Krystal.Stanley@state.de.us
Recommendations:
Additional air quality measures may be taken to substantially reduce the air emissions
identified above. These measures include:
• Constructing only energy efficient homes. Energy Star qualified homes are up to 30%
more energy efficient than typical homes. These savings come from building envelope
upgrades, high performance windows, controlled air infiltration, upgraded heating and air
conditioning systems, tight duct systems and upgraded water-heating equipment. Every
percentage of increased energy efficiency translates into a percent reduction in pollution.
The Energy Star Program is excellent way to save on energy costs and reduce air
pollution.
• Offering geothermal and/or photo voltaic energy options. These systems can
significantly reduce emissions from electrical generation, and from the use of oil or gas
heating equipment.
• Providing tie-ins to the nearest bike paths and links to any nearby mass transport
system. These measures can significantly reduce mobile source emissions.
• Funding a lawnmower exchange program. New lawn and garden equipment emits
significantly less than equipment as little as 7 years old, and may significantly reduce
Paj 139
PLUS 2010-02-01
Page 10 of 10
emissions from this new development. The builder could fund such a program for the
new occupants.
Additionally, the following measures will reduce emissions associated with the actual
construction phase of the development:
• Using retrofitted diesel engines during construction. This includes equipment that are
on-site as well as equipment used to transport materials to and from site.
• Using pre-painted/pre-coated flooring, cabinets, fencing, etc. These measures can
significantly reduce the emission of VOCs from typical architectural coating operations.
• Planting trees at residential units and in vegetative buffer areas. Trees reduce
emissions by trapping dust particles and by replenishing oxygen. Trees also reduce
energy emissions by cooling during the summer and by providing wind breaks in the
winter, whereby reducing air conditioning needs by up to 30 percent and saving 20 to 50
percent on fuel costs.
This is a partial list, and there are additional things that can be done to reduce the impact of the
development on air quality. The applicant should submit a plan to the DNREC Air Quality
Management Section which address the above listed measures, and that details all of the specific
emission mitigation measures that will be incorporated into the White Oak Road development
Following receipt of this letter and upon filing of an application with the local jurisdiction,
the applicant shall provide to the local jurisdiction and the Office of State Planning
Coordination a written response to comments received as a result of the pre-application
process, noting whether comments were incorporated into the project design or not and the
reason therefore.
Thank you for the opportunity to review this project. If you have any questions, please contact
me at 302-739-3090.
Sincerely,
Constance C. Holland, AICP
Director. Ofc. Of State Planning Coordination
CC: City of Dover
Paj 150
City of Dover
DATA SHEET FOR REVIEW of REVISED PARKING PLAN
DEVELOPMENT ADVISORY COMMITTEE MEETING OF October 9, 2013
PLANNING COMMISSION MEETING OF October 21, 2013
Plan Title: New Dover High School: Revised Parking Justification and
Waiver Request for Parking Reduction
MI-13-18
Associated Applications: C-10-05 Conditional Use Site Development Master Plan
Administrative Site Plan – Bid Pack A- Phase 1A: Pump Station
and Phase 1: Landscape Plan
S-11-18 Administrative Site Plan – Bid Pack C
Property Address: 1650 Forrest Avenue, Dover
Location: South side of Forrest Avenue (Route 8) and east of Dover High
Drive, approximately 1,500 feet west of Mifflin Road
Tax Parcel: ED-05-076.00-02-07.00-000
Owner: Capital School District
Site Area: 106.5222 +/- acres
Under Construction: New High School and associated stadium, sports fields & site
improvements
Sewer & Water: City of Dover
Zoning Classification: R-10 (One Family Residence Zone)
COZ-1 (Corridor Overlay Zone)
Previously Approved 12/20/2010: Waiver for Partial Elimination of Curbing
Waiver to Eliminate of Opaque Barrier (Fence Component)
Superior Urban Design Fulfillment
Accepted Parking Requirement Justification & Set Required Parking
Accepted Loading Berth Justification
Established Tree Density and Buffer Requirements
Approved Tree Mitigation Plan
Current Request: Consideration of Revised Parking Justification
Waiver Request for a Reduction in Required Parking
P. O. Box 475 Dover, DE 19903
Community Excellence Through Quality Service
Paj 151
City of Dover
CITY OF DOVER
Planning Office
DEVELOPMENT ADVISORY COMMITTEE
APPLICATION REVIEW COMMENTARY
D.A.C. MEETING DATE: October 9, 2013
APPLICATION: New Dover High School: Revised Parking Justification and Waiver Request
for Parking Reduction
FILE#: MI-13-18 REVIEWING AGENCY: City of Dover Planning
CONTACT PERSON: Dawn E. Melson-Williams, AICP and Ann Marie Townshend, AICP
PHONE#: 736-7196
PLAN SUMMARY:
This Review is for Consideration of Revised Parking Justification for parking associated with the
New Dover High School and a Waiver Request for a Reduction in the required parking. The
property is zoned R-10 (One Family Residence Zone) and subject to the COZ-1 (Corridor
Overlay Zone). The property is located on the south side of Forrest Avenue and east of Dover
High Drive. The owner of record is the Capital School District. Address: 1650 Forrest Avenue.
Tax Parcel: ED-05-076.00-02-07.00-000.
PREVIOUS PLAN APPROVAL: New Dover High School
The Planning Commission conditionally approved the Conditional Use Site Development Master
Plan for C-10-05 New Dover High School on December 20, 2010. The current Final Site Plan
(S-11-18) for the New Dover High School on file with the Planning Office dates to January 24,
2012. The Conditional Use Site Development Master Plan outlined the construction and use of a
three story 315,000 S.F. new Dover High School with associated parking, roadways, stormwater
management, landscaping, sports fields, stadium, and other associated site improvements.
The plan was reviewed under the Site Development Master Plan process (See Zoning Ordinance,
Article 10 §2.58). This process allows for a series of construction phases to be outlined in a
Master Plan for Planning Commission review and approval. Prior to each Phase of construction a
Site Plan specific to that phase is submitted for Administrative Site Plan review. The following
construction phases were identified on the Master Plan for the New Dover High School facility:
Phase 1: High School Building (315,000 S.F.) and associated parking lots (Lots A-F),
stadium of 5,000 seats with Fieldhouse, concession stand building (2,100 S.F.),
competition field, tennis courts, and four general/practice fields
Phase 2: Baseball/Softball Athletic Fields consisting of two competition fields, two
practice fields, outbuilding, and Parking Lot G
Phase 3: C.T.E. Building expansion (11,000 S.F.)
Phase 4: Classroom expansion (45,000 S.F.)
Paj 152
MI-13-18 New Dover High School: Revised Parking Justification and Parking Waiver Request
DAC Report of October 6, 2013
Page 3
The site is actively under construction with a series of Building Permits having been issued since
2011 subject to compliance with the approved Site Plan. Building Permits include Permits #11-742
Phase 1 Fence, #11-1365 Building Foundation, #12-155 School Building, and #13-931 Bid Pack G
– Stadium & Fields.
Surrounding Area:
The school site is located near a number of residential neighborhoods. The surrounding
residential neighborhoods are zoned single family residence to medium density residence zoning
classifications including R-8, R-10, R-20, RM-1, and RM-2. The Village of Cannon Mill and the
Village of Westover subdivisions abut the property to the south. The residential developments of
Cranberry Run, Heatherfield and Heatherfield East are located to the north across Forrest
Avenue (Route 8). Also along Forrest Avenue adjoining the school property are a series of lots
with single family homes which are outside City limits and under the jurisdiction of Kent
County. To the southwest of the school property are agricultural lands (Lands owned by Farms,
LP within Kent County) that are part of an Agricultural Preservation District. Also to the north of
the site (across Forrest Avenue/Route 8 and adjacent to Cranberry Run) is an Agricultural
Preservation District within a State agricultural easement (Purchase of Development Rights).
To the west of the new Dover High School site, there is a proposed multi-family development for
240 apartment units known as Leander Lakes. Leander Lakes (S-12-18) was conditionally
approved by the Planning Commission on October 15, 2012 (previously reviewed as Application
S-09-13). The Leander Lakes application is in the Check Print review process with the
reviewing agencies to obtain final plan approvals including entrance plan design review with
DelDOT regarding the design of the southern segment of Dover High Drive and the connection
to Tribbitt Street. The design and construction of Dover High Drive is a joint effort of the
Capital School District as associated with the High School project and the apartment
development of Leander Lakes.
CONDITIONAL USE
Within the R-10 zoning district, the use of this property as a school site is permitted subject to
approval of a Conditional Use by the Planning Commission. Zoning Ordinance, Article 3
Section 1.14a gives specific conditions for property size, setbacks, lot coverage percentage for
buildings, and sizing of court (courtyard) spaces for schools.
With Conditional Use Applications, the Planning Commission reviews the proposed project to
determine whether or not the intended use is appropriate in type and scale for the immediate
neighborhood. The Commission must also consider whether or not the proposed use will have
an adverse impact on the future orderly development of the surrounding area. Article 10 §1 of
the Zoning Ordinance outlines the objectives for reviewing Conditional Use applications
including accessibility for emergency response; harmony of size, location, and character, nature
and intensity of operations; site layout; access to streets by pedestrian and vehicle traffic; and
location and height of buildings, fences, landscaping and other improvements.
TRANSPORTATION AND CIRCULATION NETWORK
The approved New Dover High School Site Plan shows access from Forrest Avenue (Route 8) at
two locations. The eastern entrance from Forrest Avenue aligned with the entrance to
Heatherfield at Heatherfield Way. This entrance is to an internal circulation road. The western
entrance to the school property is from Dover High Drive which is a new public street that
Paj 153
MI-13-18 New Dover High School: Revised Parking Justification and Parking Waiver Request
DAC Report of October 6, 2013
Page 4
intersects with Forrest Avenue (Route 8). The Capital School District and Leander Lakes, LLC
have an agreement regarding the design and construction of the segments of Dover High Drive
and the connecting street segment to Tribbitt Street. The Planning Commission as part of the
Conditional Use Site Development Master Plan approval for the New Dover High School in
2010 required the dedication of right-of-way for a road interconnection to Tribbitt Street and that
this Tribbitt Street interconnection be constructed and available for use at the opening of the
High School.
The school project is constructing sidewalks along its street frontages of Forrest Avenue/Route 8
in a multi-modal path format. This concrete path follows along the school property frontage then
turns interior to the site to pass to the south of a series of residential properties before turning
back to the Forrest Avenue frontage. Sidewalk is also provided along the property frontage on
the east side of Dover High Drive. Sidewalks and paths lead from the street frontage sidewalks
into the site. The approval Site Plan also provided a bicycle/pedestrian path connecting with the
stub street of Worchester Drive in the Village of Westover, on the southeast side of the site.
Additionally, a separate sidewalk improvement project is in design at DelDOT to construct
sidewalks on the north side of Forrest Avenue/Route 8 for pedestrian travel to the school site
with a HAWK (High-Intensity Activated crosswalk) Signal crossing at the east entrance location.
PARKING SUMMARY
The parking requirement for a high school facility is based on a rate one parking space per five
seats in main auditorium/cafeteria or gymnasium. In reviewing the parking provisions of Zoning
Ordinance, Article 6, the Planning Staff in 2010 determined that the high school building and its
internal assembly type spaces of the auditorium, gyms, cafeteria, and group instruction area
should be utilized to calculate the required overall parking for the facility. The athletic facilities
would be viewed as accessory uses with no specific parking requirement.
The Parking Summary in the December 2010 Development Advisory Committee Report
identified that the initial seat counts for the assembly areas within the school building would
require 990 parking spaces. The C-10-05 Plan submitted for Planning Commission review
showed a total of 870 parking spaces on-site in the form of 795 regular surface parking spaces
including handicapped accessible spaces, 20 drop-off spaces, and 55 parallel parking spaces
along the eastern access drive. In addition, the site plan proposed 28 bus designated spaces that
could be converted to vehicle parking for 162 vehicles during events. The series of Parking Lots
were lettered A-G with the majority of the parking located to the west and southwest of the
school building and with a parking lot (Lot G) also located in the vicinity of baseball/softball
fields
With the Conditional Use Site Development Master Plan for the New Dover High School, the
applicant submitted a “Parking Requirement Justification” providing an analysis of needs for the
Planning Commission to review and determine the total number of parking spaces required. As a
result in December 2010, the Planning Commission set the number of required parking spaces
for the high school site at a minimum of 840 parking spaces. The number of 840 parking spaces
was calculated based on the rate of one parking space per five (5) seats in the Main Auditorium,
Cafeteria, and Main Gymnasium. In addition, it was noted that the bus parking lot could be
utilized during large events adding an additional 160 parking space giving the overall site a total
of 1,000 parking spaces.
Paj 154
MI-13-18 New Dover High School: Revised Parking Justification and Parking Waiver Request
DAC Report of October 6, 2013
Page 5
The following summary chart shows the parking for the Dover High School as depicted on the
current Site Plan S-11-18 dated January 24, 2012 (associated with Bid Pack C). These parking
areas are designed to be constructed as paved asphalt parking lot areas. The summary shows that
the Site Plan S-11-18 complies with the requirement to provide 840 parking spaces as set by the
Planning Commission on the high school site by providing a total of 847 regular parking spaces.
This total of 847 parking spaces does not include 24 drop-off spaces or the 28 bus parking
spaces. For large events the amount of available parking is increased by 162 parking spaces for a
total of 1,009 parking spaces when the bus parking area is converted to a car parking area.
Table 1: Parking Provided on Site Plan S-11-18
Parking Locations on Site Plan S-11-18 Number of Parking Spaces
A – Front of School Building 33 regular spaces*
20 drop-off spaces
B – West end of School Building 103 regular spaces
C – West end of School Building 292 regular spaces
D – South of School Building 221 regular spaces
E – Bus Parking Lot (West of Stadium) 28 bus parking spaces
Can be converted to 162 car spaces
F – East end of School Building 38 regular spaces
4 drop-off spaces
G – At Baseball/Softball Fields 111 regular spaces
Designated Parallel Parking along East 49 regular spaces
Entrance Drive
TOTAL PARKING SHOWN 847 regular parking spaces
24 drop-off spaces
28 bus parking spaces OR
162 car parking spaces for large events
*The number of regular spaces listed for each lot includes the total of regular parking spaces and
handicapped parking spaces.
Consideration of REVISED Parking Requirement Justification (Revised September 19, 2013)
The Zoning Ordinance includes provisions for alternative parking scenarios such as a combined
spaces provision (Article 3 §3.8).
3.8 Combined spaces. When any lot contains two or more uses having different parking
requirements, the parking requirements for each use shall apply to the extent of that use. Where
it can be conclusively demonstrated that one or more such uses will be generating a demand for
parking spaces primarily during periods when the other use or uses is not or are not in operation,
the planning commission may reduce the total parking spaces required for that use with the least
requirement.
(a) Campus Parking Plan. When a new building or building addition is made to a
campus involving multiple buildings under common ownership where one or more of the
uses will be generating demand for parking when the other use or uses are not in
operation, the applicant shall present a campus parking plan as a part of the site
development plan that includes an analysis of the parking needs based on the provisions
of section 3.8 of this article.
Paj 155
MI-13-18 New Dover High School: Revised Parking Justification and Parking Waiver Request
DAC Report of October 6, 2013
Page 6
The applicant has submitted a REVISED Parking Requirement Justification (dated 9/19/2013)
for Planning Commission review. This REVISED Parking Requirement Justification provides an
update to the analysis of parking needs to determine if a revision to the total number of parking
spaces required is necessary. The analysis focuses on the following: the uses within the building
with revised seat counts; number of students, staff, and drivers; operation timing and the methods
of how regular and parking (car and bus) and event overflow parking.
Table 2: Revised Parking Requirement Justification of 9/19/2013
Use Parking Rate: One Number of Seats Number of Parking
space per 5 seats Spaces
High School Main Auditorium 900 180
Cafeteria 600 120
Gymnasium 2,500 500
TOTAL PARKING 800 parking spaces
REQUIRED
Due to design revisions in the main auditorium the seat count has been reduced thus resulting in
a reduction in the required parking for that facility. Based on the seat counts the number of
required parking spaces would be 800 parking spaces for the high school facility. The Planning
Commission is to consider and take action on this Revised Parking Requirement Justification.
Bicycle Parking
The minimum bicycle parking is one (1) bike space for every twenty (20) parking spaces. Based
on the required number of parking spaces at 840 spaces as originally established, a minimum of
42 bicycle parking spaces were required. The Site Plan identified multiple locations for bicycle
parking racks on the high school site to provide 100 bicycle parking spaces.
Loading Spaces
Based on the use, the requirement for loading spaces buildings over 150,000 S.F, in size is to be
justified by the applicant based on needs of the school facility. In December 2010, the Planning
Commission accepted the justification for two designated loading spaces on the west side of the
building in a walled service area. The Site Plan includes this loading zone area.
Waiver Request: Reduction of Parking Requirement
Under the provisions of Zoning Ordinance, Article 6 §3.9 the Planning Commission may reduce
the parking for a site up to 50% of the required parking when “the use is adequately served by
transportation and parking alternatives.” However, the site must have an area of designated space
where parking can be constructed equal to the number being reduced and by accepting the
parking reduction the applicant agrees to construct the additional required parking in the future
should by Public Hearing the Planning Commission determines the reasons for granting the
reduction no longer exist.
The applicant has filed a Waiver Request to reduce the number of parking spaces to be
constructed at the high school. The applicant notes that the proposed Site Plan provides 758
parking spaces. This tally of 758 parking spaces includes counting the regular parking spaces, the
drop-off spaces, and the car parking spaces in bus area.
Paj 156
MI-13-18 New Dover High School: Revised Parking Justification and Parking Waiver Request
DAC Report of October 6, 2013
Page 7
Following the previously established methodology for tallying parking spaces, Planning Staff
finds that the proposed Site Plan of 9/19/2013 shows 564 regular parking spaces in Parking Lots
A- G Revised including handicapped parking spaces. The 24 drop-off spaces and the bus parking
with its potential for conversion to car parking are listed separately.
See chart below a summary of the parking revisions showing the changes in the tallies for each
parking lot. The changes to eliminate previously proposed parking lot areas occur in Parking Lot
C, Lot D, and Lot G. The format of Lot G has also been revised from a segregated parking lot to
a row of head-in parking spaces along the east entrance drive. Additionally, the applicant cites
the ability to accommodate 170* cars in the bus parking area for large events and in their request
count these spaces towards the meeting the required parking spaces available on the site. (*The
plan drawings lists162 car spaces; however, the Waiver Request notes 170 car spaces.) A
diagram showing how the bus parking area would be converted to car parking must be submitted
to ensure adequate sized parking spaces are created, fire lanes are maintained, and the method of
implementation of striping.
Table 3: Summary of Parking Revisions
Parking Lot Parking Spaces on Parking Spaces on Difference
Approved Site Plan REVISED Plan
S-11-18
A 33 33 No change
B 103 103 No change
C 292 184 -108
D 221 126 -95
E 28 bus 28 bus No change
Convert to 162 car Convert to 170 car
F 38 38 No change
G 111 31 -80
Parallel on East 49 49 No change
Entrance Drive
TOTAL 847 parking spaces 564 parking spaces Revised Plan
PARKING AND AND provides 283 less
SHOWN on Site 24 drop-off spaces 24 drop-off spaces parking spaces
28 bus spaces 28 bus spaces than Approved
Site Plan.
TOTAL 847 parking spaces 564 parking spaces
PARKING AND AND
SHOWN for 24 drop-off spaces 24 drop-off spaces
Large Events on 162 car parking for large 170 car parking for
Site events large events
TOTAL = 1009 spaces TOTAL = 734 spaces
and 24 drop-off spaces and 24 drop-off spaces
With the Waiver Request, the project seeks to only construct 564 regular parking spaces not
including the drop-off spaces and bus parking spaces or the car parking created from the
conversion of the bus parking area. This represents a reduction of 236 parking spaces or 29.5%
from the required parking of 800 parking spaces* (*If the Revised Parking Justification is
Paj 157
MI-13-18 New Dover High School: Revised Parking Justification and Parking Waiver Request
DAC Report of October 6, 2013
Page 8
accepted). The use of the 564 parking spaces as the tally of provided parking spaces follows the
previous methodology utilized for counting the available parking spaces on the site.
An alternative method of tallying the parking provided on the site is to include the additional car
parking that can be established by the conversion of the bus parking area. When these additional
car spaces are added to the parking space count towards the required parking, the project would
have 734 parking spaces thus requiring a reduction of 66 parking spaces or a reduction of 8.25%
from the required parking of 800 parking spaces.
The method is utilized by the applicant in their Waiver Request narrative goes a step further and
tallies the regular parking spaces, the converted bus parking area as car spaces, and the drop-off
spaces. This totals to 758 parking spaces provided thus requiring a reduction of 42 parking
spaces or a reduction of 5.25% from the required parking of 800 parking spaces.
If a reduction is granted, then area must be reserved for the parking. The Revised Plan identifies
a series of areas on the site for future parking expansion. These three locations provide a total of
314 parking spaces. These areas were previously identified to be developed as part of the parking
lots for the high school project. These future expansion area can be identified as Lot C-1, Lot D-
1, and Lot G – Revised. It is not clear how the head-in parking area of Lot G would be revised
for construction of the future parking Lot G.
The Planning Commission may consider a waiver request to reduce the parking requirement for
the project under the provisions of Zoning Ordinance, Article 6 §3.9 Adjustments to parking
requirements.
THE SUBJECT PROPOSAL HAS BEEN REVIEWED FOR CODE COMPLIANCE, PLAN
CONFORMITY, AND COMPLETENESS IN ACCORDANCE WITH THIS AGENCY’S
AUTHORITY AND AREA OF EXPERTISE.
CITY AND STATE CODE REQUIREMENTS:
1) A Revised Final Plan set must include notes indicating the action taken by the Planning
Commission in regards to any waivers and listing any additional conditions of approval. The
plan set is be revised to reflect all changes recommended and adopted by the Planning
Commission.
2) The narrative entitled “Parking Requirement Justification and Waiver Request” presents a
revised analysis of parking needs for the site. The Planning Commission is to review this
information and set the total number of parking spaces required for the site.
3) Parking shall be provided in accordance with the Zoning Ordinance unless a waiver is
granted by the Planning Commission. A written waiver request has been to reduce the
parking requirement for consideration by the Planning Commission.
4) Clarify the differences in the number of parking spaces provided. Narrative lists 758 parking
spaces constructed appears to count the regular spaces, the drop-off spaces, and the car
parking in the converted bus parking lot. The approved methodology must be listed on the
plan.
Paj 158
MI-13-18 New Dover High School: Revised Parking Justification and Parking Waiver Request
DAC Report of October 6, 2013
Page 9
5) Sheet C-001:
a) Add notes outlining the actions taken by the Planning Commission on the series of
waivers requested and items of consideration.
6) Add note regarding parking lot construction requirements for future reserved parking areas.
7) Provide a plan diagram for the striping of the bus parking area to accommodate vehicle (car)
parking as proposed for large event parking in order to confirm the number of parking spaces
that would be available for use in this Lot E. Parking space sizes, fire lanes, and method of
pavement marking should be shown.
8) Clarify the bicycle parking location at the baseball/softball fields as the previous location
appears to have been redesigned with the removal of the large outbuilding. The approved Site
Plan (S-11-18) showed a total of 50 racks for 100 bicycle parking spaces on the high school
site.
9) Submission of Revised Site Plans and Construction Plans will necessary to reflect changes in
the site design resulting from the elimination of parking areas or revisions to parking format
(Lot G area). This may impact stormwater management plans, landscape plans, utility plans,
etc.
RECOMMENDATIONS SUGGESTED AS CONDITIONS OF APPROVAL TO MEET CODE
OBJECTIVES:
1) In consideration of a Conditional Use Application, one of the objectives to be satisfied is that
the “site layout and its relation to access streets shall be such that both pedestrian and
vehicular traffic to and from the use and the assembly of persons in connection therewith will
not be hazardous or inconvenient to, or incongruous with, the said residential district or
conflict with the normal traffic of the neighborhood.” Planning Staff is concerned that
significant reductions in the number of parking spaces on the high school site will result in
site visitors parking in adjacent residential neighborhoods on a regular basis particularly on
the east side of the site.
2) Revised Parking Justification: Planning Staff accepts the REVISED parking analysis
presented in the “Parking Requirement Justification” segment of the document as revised
9/19/2013 and recommends that the minimum parking requirement for the site be set at 800
parking spaces for the high school site. This revision continues to recognize that the parking
calculation is based on the seat count of the main auditorium, cafeteria, and main gymnasium
spaces only. This revision recognizes the changes in the building design/construction
resulting in a reduction in the seating capacity of the main auditorium from 1,100 seats to
900 seats.
a) The site includes opportunities for multi-modal travel (vehicle, school bus, bicycle, and
pedestrian).
b) Staff also recognizes the ability of the site to provide parking alternatives such as
utilization of bus parking areas for vehicle parking during special events.
Paj 159
MI-13-18 New Dover High School: Revised Parking Justification and Parking Waiver Request
DAC Report of October 6, 2013
Page 10
3) Waiver Request for Parking Reduction: Planning Staff recommends approval of the parking
reduction of the 203 parking spaces (parking reductions in Lot C at 108 spaces and Lot D at
95 spaces) on the west side of the site. This reduction of 203 parking spaces is a parking
reduction of 25.375%.
a) Planning Staff in considering the waiver request is not including the 170 car parking
spaces in the converted bus parking Lot E for large events or the drop-off spaces as
counting towards the required parking for the site. This follows the previous
methodology for counting parking on site.
b) Areas must be reserved for the construction of parking areas equal to the amount of any
parking reduction. If in the future parking becomes an issue at the site then the provisions
of Zoning Ordinance, Article 6 §3.9 can be implemented to construct parking spaces in
the reserved areas.
4) Staff is concerned that the elimination of parking on the east side of the site near the baseball
and softball fields will cause parking for practices and events on these fields to spill over into
the streets of the adjacent residential neighborhood of the Village of Westover. While the
proposed Revised Lot G will provide 31 head-in parking spaces, the format of the parking
versus the east entrance drive is a concern. Further consideration of a revised design for the
original segregated Lot G parking lot may be more appropriate from a safety perspective and
have the ability to accommodate more parking for this area while allowing for future parking
expansion. A design constructing the first double loading drive aisle of the segregated
parking lot could provide approximately 48 parking spaces.
ADVISORY COMMENTS TO THE APPLICANT:
1) The Planning Commission will act upon the waiver request as part of a motion. All waivers
are at the discretion of the Planning Commission. The Commission may approve or deny
waiver requests.
2) Other agencies and departments which participate in the Development Advisory Committee
may provide additional comments related to their areas of expertise and code requirements.
3) In the event, that major changes and revisions to the plan occur regarding the Site
Development Master Plan as approved contact the Department of Planning and Inspections.
The changes may require resubmittal for review by the Development Advisory Committee,
Planning Commission, or other agencies and commissions making recommendations in
regards to the overall Master Plan.
If you have any questions or need to discuss any of the above comments, please call the
above contact person and the Planning Department as soon as possible.
Paj 160
CITY OF DOVER
DEVELOPMENT ADVISORY COMMITTEE
APPLICATION REVIEW COMMENTARY
STAFF D.A.C. MEETING DATE: OCTOBER 2, 2013
APPLICATION: New Dover High School : Revised Parking
Justification and Waiver Request for Parking
Reduction
FILE #: MI-13-18
REVIEWING AGENCY: City of Dover Electric and Public Works Departments
CONTACT PERSON: Steve Enss - Electric
Jason A. Lyon, P.E. – Public Works
CONTACT PHONE #: Electric - 302-736-7070 Public Works – 302-736-7025
T HE S UBJECT P ROPOSAL HAS BEEN R EVIEWED FOR C ODE C OMPLIANCE , P LAN C ONFORMITY AND C OMPLETENESS IN
A CCORDANCE WITH THIS A GENCY ’ S A UTHORITY AND A REA OF E XPERTISE .
T HE F OLLOWING I TEMS HAVE BEEN I DENTIFIED AS E LEMENTS W HICH N EED TO BE A DDRESSED BY THE A PPLICANT :
CITY AND STATE CODE REQUIREMENTS
ELECTRIC
1. None
WATER
1. All water utility components must meet the requirements of the Water Wastewater Handbook, effective date March 22,
2010. Please contact our office for more information.
WASTEWATER
1. All wastewater utility components must meet the requirements of the Water Wastewater Handbook, effective date
March 22, 2010. Please contact our office for more information.
STORMWATER
1. Final site plan approval will not be granted until a copy of the approved Stormwater/Erosion and Sediment Control
Plan from Kent Conservation District is submitted to our office.
STREETS / SANITATION / GROUNDS / GENERAL
1. None
RECOMMENDATIONS SUGGESTED AS CONDITIONS OF APPROVAL TO MEET CODE OBJECTIVES
ELECTRIC / WATER / WASTEWATER / STORMWATER / STREETS / SANITATION / GROUNDS
1. None.
ADVISORY COMMENTS TO THE APPLICANT
ELECTRIC / WATER / WASTEWATER / STORMWATER / SANITATION / GROUNDS / GENERAL
1. None
Paj 161
Request for Street Abandonnent : Harmony Lane
File #: MI-13-16
October 2, 2013
Page 2 of 2
STREETS
1. Staff has concerns about the reduction of parking and the possibility of additional parking taking place within the
Village of Westover.
I F Y OU H AVE A NY Q UESTIONS OR N EED TO D ISCUSS ANY OF THE A BOVE C OMMENTS , P LEASE C ALL THE A BOVE
C ONTACT P ERSON AND THE P LANNING D EPARTMENT AS S OON AS P OSSIBLE .
Paj 162
CITY OF DOVER D
E
DEVELOPMENT ADVISORY COMMITTEE
L
APPLICATION REVIEW COMMENTARY D
O
D.A.C. MEETING DATE: October 2, 2013 T
===============================================================
APPLICATION: MI-13-18 New Dover High School: Revised Parking Justification and
Waiver Request for Parking Reduction
FILE#: MI-13-18 REVIEWING AGENCY: DelDOT
CONTACT PERSON: Julio F. Seneus PHONE#: 760-2145
===============================================================
THE SUBJECT PROPOSAL HAS BEEN REVIEWED FOR CODE COMPLIANCE, PLAN CONFORMITY AND COMPLETENESS IN
ACCORDANCE WITH THIS AGENCY'S AUTHORITY AND AREA OF EXPERTISE.
THE FOLLOWING ITEMS HAVE BEEN IDENTIFIED AS ELEMENTS WHICH NEED TO BE ADDRESSED BY THE APPLICANT:
CITY & STATE CODE REQUIREMENTS:
1. The Department has no comments.
RECOMMENDATIONS SUGGESTED AS CONDITIONS OF APPROVAL TO MEET CODE
OBJECTIVES:
ADVISORY COMMENTS TO THE APPLICANT:
If you have any questions or need to discuss any of the above comments, please call the
above contact person and the planning department as soon as possible.
Paj 163
DEPARTMENT OF NATURAL RESOURCES
AND ENVIRONMENTAL CONTROL
DIVISION OF WATERSHED STEWARDSHIP
89 KINGS HIGHWAY
DOVER, DELAWARE 19901
OFFICE OF THE PHONE: (302) 739-9921
DIRECTOR FAX: (302) 739-6724
Memorandum
DATE: October 1, 2013
TO: Dawn Melson-Williams, Planner
City of Dover
FROM: Elaine Z. Webb, P.E., Engineer IV
Sediment & Stormwater Program
RE: Development Advisory Committee
MI-13-18 New Dover HS Parking Waiver Request
CC: Jamie Rutherford, Program Manager
Michael Riemann, Becker Morgan Group
DNREC offers the following comments on the above referenced application:
1. Even if the east entrance will not be constructed at this time, the outlet pipe from Pond 2
must be constructed. DNREC will require the pond outlet to be installed prior to signing
off on the Certificate of Occupancy for the building.
2. Lot G which serves the baseball and softball field area was originally approved with a
bioswale for stormwater quality management. The plan revision shows new parking
spaces to be included at the location of the bioswale. A Sediment and Stormwater Plan
Revision must be submitted for approval for this condition. Stormwater quality
management must be provided for this revision.
3. Both parking areas on the west side of the site that are proposed to be removed contain
bioswales for stormwater quality management. The bioswales will need to be
constructed regardless of whether the parking is constructed or not. It is possible that the
bioswale cross section may be reduced, or the bioswale may be eliminated, but this will
required a revision to the Sediment and Stormwater Plan for the project as well.
4. In many areas on the site, bioswales adjoin parking areas. It is important to consider
where cars may park when all of the designated parking spaces are filled. Vehicles must
be restricted from parking within stormwater management facilities such as bioswales,
filter strips, etc. because those facilities will fail to function as intended if the soil
becomes compacted due to parking.
If you should have any questions, please do not hesitate to contact me at (302) 739-9921 or
Elaine.Webb@state.de.us.
Delaware’s good nature depends on you!