Ale nan kontni prensipal la
AskDover

Entèlijans atifisyèl (AI) tradui paj sa a. Pèsonn pa revize li, e li ka gen erè. Gade vèsyon angle a

PC Paperless Packet REVISED

Planning Commission. 21 fevriye 2023.

Louvri PDF la

Yo rale tèks sa a nan PDF la otomatikman, epi li ka gen erè. PDF la se dosye ofisyèl la, kidonk tcheke l anvan ou konte sou sa a.

4 paj pa gen anpil tèks ou ka li isit la, oswa yo pa gen ditou, souvan paske se eskanè oswa desen. Gade PDF la pou sa yo.

Paj 1

CITY OF DOVER, DELAWARE PLANNING COMMISSION Tuesday, February 21, 2023 at 7:00 PM City Hall Council Chambers, 15 Loockerman Plaza, Dover, Delaware *REVISED* AGENDA *The Agenda for the February 21, 2023 Meeting has been revised in order to accommodate a Request for Extension of Planning Commission Approval for Development Master Site Plan Application S-21-03 Three Lots at Secure Storage on Lafferty Lane: Master Plan. This has been added as an item of Old Business. Written comments are accepted via mail to City of Dover – Planning Commission, P.O. Box 475 Dover DE 19903 and via email at CompPlan@dover.de.us. IN-PERSON and VIRTUAL MEETING NOTICE The Planning Commission Meeting for February 21, 2023 will be held as an In-Person Meeting at City Hall in City Council Chambers. The public is welcome to attend in person. The meeting will also be provided as a Virtual Meeting using WebEx audio/visual conferencing as an electronic means of communication. See participation information below to join by phone or computer. PUBLIC PARTICIPATION INFORMATION City of Dover Planning Commission Meeting of February 21, 2023 Dial: 1-650-479-3208 Event number/Access code: 2534 985 9381 Event password: DoverPC Event Address: https://bit.ly/PCMeeting2212023 If you are new to WebEx, get the app now at https://www.webex.com/ to be ready when the meeting starts. For problems accessing the meeting, please call the Planning Office at (302) 736- 7196. CALL TO ORDER PLEDGE OF ALLEGIANCE ROLL CALL ADOPTION OF AGENDA 1

Paj 2

PLANNING COMMISSION - February 21, 2023 REVISED PAGE 2 Application C-23-01 TLC Childcare, LLC at 901 S. State Street was withdrawn by the applicant and will not be heard by the Planning Commission. APPROVAL OF MINUTES 1. Adoption of the Minutes of January 17, 2023 COMMUNICATIONS & REPORTS 2. University of Delaware - Institute for Public Administration presents an In Person Training event:  Advanced land Use Law - Friday March 3, 2023, 9:00 AM to 12:00 PM Kent County Levy Court, 555 S Bay Rd, Dover, DE 19901, Room 220 Meeting Reminder: The next Planning Commission regular meeting date is scheduled for Monday, March 20, 2023 at 7:00pm. Update on City Council Actions Department of Planning & Inspections Updates 3. Summaries of 2022 Applications presented with the Annual Report OPENING REMARKS CONCERNING MEETING PROCEDURES FOR APPLICATIONS OLD BUSINESS Request Extension of Planning Commission Approval 4. S-21-03 Three Lots at Secure Storage on Lafferty Lane: Master Plan - Request for one year extension of Planning Commission Approval granted March 15, 2021 of a Conditional Use Site Plan for the construction of Site Development Master Plan Application to permit development of three (3) existing parcels. The parcels are listed as Lots 2, 3, and 4 respectively; with Lot 1 being the main parcel for the Secure Storage Facility. Lot 2 is proposed to contain a Building of 23,600 +/- SF with associated site improvements. Lot 3 is proposed to contain a Building of 23,600 +/- SF with associated site improvements. Lot 4 is proposed to contain a Building of 21,400 +/-SF with associated site improvements. The proposed development area of the three Lots totals 7.67 acres +/- and is zoned IPM (Industrial Park and Manufacturing Zone). The land tracts are located on the north side of Lafferty Lane and east of Bay Road. The owner of record is Secure Storage LLC. Property Addresses: unaddressed but are adjacent to 640 Lafferty Lane. Tax Parcels: ED- 05-077.00-01-25.01-000, ED-05-077.00-01-25.02-000, and ED-05-077.00-01-25.03-000. Council District 2. The three Lots were created as part of a Minor Subdivision Plan with Site Plan S-02-23 Secure Storage LLC for Mini-Storage Facility (Lot 1) in 2002. NEW APPLICATIONS 5. S-23-03 NeighborGood Partners Division Street Office at 223 West Division Street – Public Hearing and Review of a Site Development Plan Application to permit construction of a two- story 6,226 SF office building and associated site improvements. The property is zoned C-1A (Limited Commercial Zone). The property is located on the north side of W. Division Street, east of N. New Street. The owner of record is NCALL, Inc. Property Address: 223 W. 2

Paj 3

PLANNING COMMISSION - February 21, 2023 REVISED PAGE 3 Division Street. Tax Parcel: ED-05-076.08-05-29.00-000. Council District 4. Waiver Request: Elimination of Upright Curbing. For Consideration: Tree Mitigation Plan. This site was most recently subject to Site Development Plan Application S-19-13 which was approved by Planning Commission in July 2019, but construction had not commenced, and Plan Approval has since expired. 6. S-23-04 Leander Lakes III Apartments – Public Hearing and Review of a Site Development Application for the construction of eight (8) 3-story garden style apartment buildings, and 1 (one) 2-story 8 unit building for a total of two hundred (200) units. Also proposed are 450 parking spaces, walking paths, landscaping, recreation areas and other site improvements. The project area of 25 acres is zoned RM-2 (Medium Density Residence Zone) and partially subject to the COZ-1 (Corridor Overlay Zone) with the balance of the overall property zoned R-10 (One Family Residence Zone and partially subject to COZ-1 (Commercial Overlay Zone). The application includes a Minor Subdivision Plan to create Lot 1 of 50.19 acres+/- (residual) and Lot 2 of 25 acres (project area). The property is located on the south side of Forrest Ave west of Dover High Drive. The owner of record is Calvary Baptist Church of Dover and equitable owner/developer is Leander Lakes III, LLC. Property is currently addressed as 2285 Forrest Avenue. Tax Parcel: ED-05-075.00-01-06.00-000. Council District 1. For Consideration: Active Recreation Area Plan. The property was the subject of Rezoning Application Z-22-02 approved October 2022 and Conditional Use Site Plan Application C-19-06 Calvary Baptist Church. 7. S-23-05 Tidal Wave Auto Spa at 245 N. Dupont Highway - Public Hearing and Review of a Site Development Plan and Lot Consolidation Plan for two (2) parcels totaling 2.15 +/- acres at 245 North DuPont Highway. The Plan is to permit construction of a 3,690 SF Car Wash facility, 24 vacuum spaces, and associated site improvements. The properties are zoned C-4 (Highway Commercial Zone). The parcels consist of a total of 2.15 +/- acres and is located on the northeastern corner of N Dupont Highway and White Oak Road. The owner of record is TWAS Properties LLC. Property Addresses: 245 and 243 N Dupont Highway. Tax Parcel IDs: ED-05-068.18-01-13.00-000 and ED-05-068.18-01-12.00-000. 8. MI-23-01 Comprehensive Plan Amendments 2023 – Public Hearing and Review for Recommendation to City Council of a series of Amendments to the 2019 Comprehensive Plan, as amended. The Amendments include consideration of the following as associated with Annexation Application AX-23-01 Lands of Calpine Holdings, LLC – Two Properties on White Oak Road: requests for amendment of Map 13-1: Potential Annexation Areas to revise the Annexation Plan category of two properties and requests for amendment of Map 13-2: Potential Land Uses for Annexation Areas to identify the Land Use Classification of two properties. A. Consideration of Amendments to Map 13-1: Potential Annexation Areas Plan Map - Request for two parcels located on the north side of White Oak Road and west of Bayside Drive to revise the Annexation Plan category from Area of Concern and unidentified area to Category 2: Priority Annexation Area on Map 13-1: Potential Annexation Areas Plan Map. (Planning Reference: MI-23-01A) a. Property Area: 144.83 acres +/-. Property Address: unaddressed parcel near White Oak Road. Property Owner: Calpine Holdings, LLC. Tax Parcel: LC-00-058.00-02-49.00- 000. 3

Paj 4

PLANNING COMMISSION - February 21, 2023 REVISED PAGE 4 2019 Comprehensive Plan, Map 13-1 – Annexation Plan Category: None Proposed Comprehensive Plan Designation, Map 13-1 Annexation Plan Category: Category 2 – Priority Annexation Area b. Property Area: 104.06 acres +/-. Property Address: 3015 White Oak Road. Property Owner: Calpine Holdings, LLC. Tax Parcel: LC-00-058.00-02-48.00-000. 2019 Comprehensive Plan, Map 13-1 – Annexation Plan Category: Area of Concern Proposed Comprehensive Plan Designation, Map 13-1 Annexation Plan Category: Category 2 – Priority Annexation Area B. Consideration of Amendments to Map 13-2: Potential Land Use for Annexation Areas Map - Request for two parcels located on the north side of White Oak Road and west of Bayside Drive to identify the Land Use Classification as Public & Private Utilities on Map 13-2: Potential Land Use for Annexation Areas Map. (Planning Reference: MI-23- 01B) a. Property Area: 144.83 acres +/-. Property Address: unaddressed parcel near White Oak Road. Property Owner: Calpine Holdings, LLC. Tax Parcel: LC-00-058.00-02- 49.00-000. 2019 Comprehensive Plan, Map 13-2 – Land Use Classification: None Proposed Comprehensive Plan Designation, Map 13-2 Land Use Classification: Public & Private Utilities b. Property Area: 104.06 acres +/-. Property Address: 3015 White Oak Road. Property Owner: Calpine Holdings, LLC. Tax Parcel: LC-00-058.00-02-48.00-000. 2019 Comprehensive Plan, Map 13-2: Land Use Classification: None Proposed Comprehensive Plan Designation, Map 13-2 Land Use Classification: Public & Private Utilities NEW BUSINESS ADJOURN Posted Agenda: February 10, 2023 Posted Revised Agenda: February 14, 2023 THE AGENDA ITEMS AS LISTED MAY NOT BE CONSIDERED IN SEQUENCE. PURSUANT TO 29 DEL. C. §10004(e)(2), THIS AGENDA IS SUBJECT TO CHANGE TO INCLUDE THE ADDITION OR THE DELETION OF ITEMS, INCLUDING EXECUTIVE SESSIONS, WHICH ARISE AT THE TIME OF THE MEETING 4

Paj 5

Item 1. CITY OF DOVER PLANNING COMMISSION JANUARY 17, 2023 The Meeting of the City of Dover Planning Commission was held on Tuesday, January 17, 2023 at 7:00 PM as an In-Person Meeting and also using the phone/videoconferencing system WebEx. The Meeting Session was conducted with Chair Mrs. Maucher presiding. Members present were Mr. Roach (virtual), Mrs. Denney, Mr. Hartman, Mr. Baldwin, Dr. Jones, Mrs. Welsh (virtual), Mrs. Malone (virtual), and Mrs. Maucher. Mr. Cooper was absent. Staff members present were Mrs. Mary Ellen Gray, Mrs. Dawn Melson-Williams, Mr. Julian Swierczek, Ms. Katherine Oehmke, Mr. Jason Lyon (virtual), and Mrs. Kristen Mullaney. Also present were Mr. Mark North (virtual) and Mr. Dave Heatwole. Speaking from the public was Ms. Linda Parkowski. APPROVAL OF AGENDA Mrs. Maucher stated that the Commission was provided with a Revised Agenda which adds under Old Business, a Request for Extension of Planning Commission approval for a Conditional Use Site Plan application C-21-01 Cassidy Commons at 101-1001 Cassidy Drive. Dr. Jones moved to approve the Revised Agenda as submitted, seconded by Mr. Baldwin and the motion was unanimously carried 8-0 with Mr. Cooper absent. APPROVAL OF MEETING MINUTES OF DECEMBER 19, 2022 Mrs. Welsh moved to approve the Planning Commission Meeting Minutes of December 19, 2022, seconded by Mrs. Denney and the motion was unanimously carried 8-0 with Mr. Cooper absent. COMMUNICATIONS & REPORTS Mrs. Gray provided an update on the regular City Council and various Committee meetings held on January 9 & 10, 2023. Mrs. Melson-Williams stated that the next Planning Commission regular meeting is scheduled for Tuesday, February 21, 2023 at 7:00PM in the City Hall Council Chambers. Mrs. Melson-Williams stated that as the Chair noted in the intro, we have a new member of the Planning Staff that has joined us, Ms. Katherine Oehmke. Mrs. Melson-Williams stated that included in the packet was a Summary of Applications for 2022. This is a first look at some of our year-end tallies that they do coming out of a calendar year-end. You can see for 2022 overall, our Office was processing with our various Boards and Commissions, a total of 42 applications. That seems slightly lower when you look at 2021 but from a Site Plan perspective, they were just as busy with applications this year. If you will remember since your approvals are granted for a two-year timeframe, we are still dealing with projects back from 2020 which may be trying to finalize their plan or may still be in the construction stage. They are certainly busy and they have had some big projects come in over that timeframe. There will be more detailed information about the various applications as part of our Department’s Annual Report. They will make sure that comes forward to the Commission. 1 5

Paj 6

Item 1. CITY OF DOVER PLANNING COMMISSION JANUARY 17, 2023 Mrs. Melson-Williams stated that included in the packet are two of the upcoming Zoom presentations done by the University of Delaware’s Institute for Public Administration. One of them is tomorrow morning which is “Planning 101: Planning Your Community’s Future” and then the next one is on February 8, 2023 at 10AM. With those items, if you wish to participate in them, please reach out to Planning Staff and they can get you registered. There is a registration fee which Planning Staff has some training money that can help fund that. She is not sure if it is too late to join tomorrow’s training but if anyone is interested, let them know and they will reach out to see if that can happen. As they set the rest of their calendar, Staff will certainly bring those opportunities to the Commission as well. OPENING REMARKS CONCERNING DEVELOPMENT APPLICATIONS Mrs. Melson-Williams presented the audience information on policies and procedures for the In- Person Meeting and Virtual Meeting using the WebEx system. OLD BUSINESS Requests for Extensions of Planning Commission Approval: C-21-01 Cassidy Commons at 101-1001 Cassidy Drive – Request for one year extension of Planning Commission Approval granted January 19, 2021 of a Conditional Use Site Plan for the construction of six (6) additional manufacturing/warehousing buildings (in addition to the four (4) already constructed) for a total of ten (10) 9,950 SF manufacturing/warehousing buildings on one parcel of land and other associated site improvements at 101-1001 Cassidy Drive. The property is 10 acres ± and is zoned M (Manufacturing Zone) and is subject to the AEOZ (Airport Environs Overlay Zone) APZ I and Noise Zones A and B. The property is located on the south side of Lafferty Lane west of Horsepond Road along a private drive known as Cassidy Drive. The owner of record was Cassidy Commons, LLC at time of original application; the current owner of record is Delmarva Land Holdings, LLC. Property Address: 101-1001 Cassidy Drive. Tax Parcel: ED05-077.00-01-28.04-000. Council District 2. This Application received Conditional Approval from the Planning Commission at their January 2021 Meeting and has not achieved Final Plan Approval. Representative: Mr. Mark North (virtual), Mrs. Melson-Williams stated that this is application C-21-01 for Cassidy Commons. It was a project to continue development of a multi-building warehouse complex out on Lafferty Lane. It originally went through a review process back in 2011 after which time they built four of the ten buildings that are proposed. That Plan, due to lack of continuation of construction, expired and they filed C-21-01 to basically complete the balance of the project development. Again, showing the remaining six buildings to bring it to a total of ten buildings on their plan. The Planning Commission granted conditional approval in January 2021. At this point, they have yet to fully complete the Check Print Review Process to get to Final Plan Approval. In that timeframe, there has also been an ownership change that happened about the time that it was coming back through Planning Commission in January 2021. Tonight, by letter dated January 9, 2023, they are requesting a one year extension of their approval for application C-21-01. 2 6

Paj 7

Item 1. CITY OF DOVER PLANNING COMMISSION JANUARY 17, 2023 Mr. North stated that there was a change of ownership about two years ago and it has taken a little bit of time to get a forward momentum back on the project. They plan to build the project exactly how it was proposed at the last application and they are very close to submitting the Check Print. It will probably be within the month. The new owner is supposed to proceed and build the project exactly as proposed previously. Mr. Hartman stated that during the meeting two years ago, there were some concerns expressed in the DAC Report about non-compliance issues. One was actually made by the Fire Marshal, he believes. Are there any concerns with non-compliance issues at this location that would impact or that should be considered by the Commissioners when considering this extension approval? Responding to Mr. Hartman, Mrs. Melson-Williams stated that there was some concerns at the time with this being a multiple building, multiple tenants within each of those buildings. There are a number of tenants that for one reason or another may have taken up tenancy there without proper Business Licensing in place. She thinks that those items have been resolved and certainly moving forward, it is a location that she believes our Code Enforcement Staff does try to keep an eye on. It does make a difference from a zoning perspective because of the zoning of this property and its proximity to the Air Force Base. They have to look very carefully at the types of tenants that seek to go there. She thinks that those previous items have been resolved, but it will certainly remain on our radar screen. Mr. Hartman questioned if there was a Performance Standard for this site. Responding to Mr. Hartman, Mrs. Melson-Williams stated yes, there is a Performance Standards that was put in place. That is something that they can continue to point to with them finalizing the plan as well as construction of new buildings and new tenants taking occupancy there. Mr. Hartman questioned if the Business License was the City’s main tool to use when assessing whether the Performance Standards are met. Responding to Mr. Hartman, Mrs. Melson-Williams stated that one of the tools for dealing with the Performance Standards starts with the Building Permit Application because there will be some type of occupancy identified at that point in time. The Business Licensing processing is another check for that and of course just regular property maintenance compliance checks. Are they storing things outside and things of that nature that they can look to deal with any kind of compliance questions and those Performance Standards measures. Mr. Hartman stated that he would just like to have faith that when they (Commissioners) approve these Performance Standards that there is actually follow up by the city to make sure that they are being followed, especially in areas like this as Dover Air Force Base is a critical part of the community. Mrs. Denney stated that she agrees. The close proximity to the Air Base, in her opinion, means that everything has to be really observed and they have to be doing things by the rules. She tends to think that happens anyway. When she looks at this she thinks to herself, the granting of the Certificate of Occupancy will mean that they have to comply with everything in order to get that Certificate of Occupancy. She doesn’t want to assume that; she wants to know that that is true. Responding to Mrs. Denney, Mrs. Melson-Williams stated that as part of the process for issuance of a Certificate of Occupancy, there are of course inspections by the Building Inspectors, the Fire 3 7

Paj 8

Item 1. CITY OF DOVER PLANNING COMMISSION JANUARY 17, 2023 Marshal’s Office, the Planning Office, and inspections from our Department of Water/Wastewater. They are all involved in order for a project to achieve a Certificate of Occupancy at the end of construction. Mrs. Denney moved to approve C-21-01 Cassidy Commons at 101-1001 Cassidy Drive for a one-year extension, seconded by Mr. Hartman and the motion was carried 8-0 by roll call vote with Mr. Cooper absent. Mrs. Denney voting yes; as indicated in the motion. Mr. Hartman voting yes; based on the review that was done two years ago for this application. Mr. Baldwin voting yes. Dr. Jones voting yes. Mrs. Welsh voting yes; for reasons stated. Mrs. Malone voting yes; for reasons stated. Mr. Roach voting yes; for reasons previously stated. Mrs. Maucher voting yes; for reasons stated. NEW APPLICATIONS S-23-01 East Carolina Supply Warehouse on Ridgely Street – Public Hearing and Review of a Site Development Plan and Minor Subdivision Plan for a property currently addressed as 631 Ridgely Street. The Plan proposes to subdivide the current parcel of 28.65 +/- acres into two new parcels. The proposed Parcel A is southernmost portion of the site and is to be 4.928 +/- acres (214,643 SF). The Residual Parcel is the northern portion of the site containing an existing warehouse building and would be 23.726 +/- acres (1,033,516 SF). The Plan is to permit construction on Parcel A of a 42,400 SF +/- warehouse and associated site improvements. The current property is zoned IPM (Industrial Park Manufacturing Zone). The property is located north of the terminus of Ridgely Street and at Clara Street to the west of the railroad. The owner of record is Clara Ridgley Project, LLC. Property Address: 631 Ridgely Street. Tax Parcel: ED- 05-076.08-01-01.00-000. Council District 4. Waiver Requests: Partial Elimination of Curbing, Reduction of Parking Requirement, and a Subdivision Waiver to Create Lot without Frontage on a Public Street. For Consideration: Performance Standards Review. Representative: Mr. Dave Heatwole, Siteworks Engineering Mr. Swierczek stated that this is an application for both a Site Development Plan and an associated Minor Subdivision Plan. The parcel of land is currently a little over 28.5 acres. The Minor Subdivision Plan is proposing a 23.7-acre parcel to the north that would be the bulk of the existing land that will also contain the existing warehouse building. The second parcel to be created would be to the south and that would be just under 5 acres. That southern parcel of land would then be proposed to contain a new warehouse building which is the Site Development Plan portion of this application and that would be 42,400 SF. With that, there is first a Subdivision Waiver that they will be submitting. The Ridgely Street’s public right-of-way does not extend this far north. There is sort of an existing easement on this property. They are asking for the Subdivision Waiver so that they can establish a cross access easement to allow access from the Ridgely Street to the south across this property to the larger parcel to the north. They have additionally submitted Waiver Requests for the partial elimination of the 6-inch upright curbing for stormwater management and they have also submitted a Waiver for the reduction in parking. Fifty-three parking spaces would be required, and they are asking for it to be reduced to twenty-seven. In their Waiver Request, they have noted that they expect about five employees to work at this facility at once as the main reason for their reduction in parking. Lastly, they did submit a Performance Standards Review Application due to the zoning of this property being 4 8

Paj 9

Item 1. CITY OF DOVER PLANNING COMMISSION JANUARY 17, 2023 IPM (Industrial Park Manufacturing Zone). The Performance Standards Review Application was required to ensure that no undesirable activities or chemicals or anything of that nature will be present onsite. Planning Staff finds that the literature that they submitted meets those requirements but that will have to be something that the Planning Commission takes a vote on. Mr. Heatwole stated that this is a project that they are really excited about. It’s a redevelopment project. They are putting a 42,000 SF warehouse in an existing area that is paved. They are going to take up the paving and put the warehouse in. They are going to see a reduction in paving by about 23% so that is going to help the drainage in the area. It is at a great location. Behind them is an existing mini-storage complex. There is a cell tower on their property and then they are in the IPM (Industrial Park Manufacturing Zone). The property to the south is also IPM (Industrial Park Manufacturing Zone). There is already over 1 million square feet of warehousing on the parent parcel; so, they are just going to do a small portion. They are doing 42,000 SF which is quite a bit less than the 1 million that is already present. There is water and sewer on the easement and there is also electric and gas. So, they don’t have to go far for utilities. It is a great spot for development, and he feels like it is going to pull development Downtown which is a good thing. One of the challenges that they face is with curbing. They are asking for the Waiver to create a new lot off of an easement and then they are asking for also a waiver with the curbing. They are planning to put curbing on the front of the building on the front side. That is easier for them to do because they can super-elevate that road and maintain existing drainage patterns, but on the back side is where they are asking to not put in the curbing. They have just over two feet of fall that they have to deal with across the site. When you put in a curb, you kind of concentrate the flows and they want to kind of fan out the water. They are going to push it more into the grass so that as it goes to the property to the south, it is not creating a concentrated channel going onto the property which would impact that. Mrs. Maucher asked if he wanted to address the request for the Waiver to create a lot without frontage on a public street. Responding to Mrs. Maucher, Mr. Heatwole stated that right now to the south, which is the right side of the plan, Ridgely Street is 408 feet to the right. There is an easement that runs across the lot to the south that provides access. This is existing so trucks use this easement to access this existing warehouse. If you go to Sheet RP-2, see the hashed area or darker area that goes from Clara Street Extension and wraps all the way around. What they are purposing is a cross access easement so both parcels can continue to use both Ridgely Street and Clara Street Extension with essentially no change to the parcels. Mrs. Maucher asked if those easements were in place. Responding to Mrs. Maucher, Mr. Heatwole stated that they will be in place once they record the Subdivision. Mr. Hartman stated that he thinks it is well presented and the proposal will probably improve the area, but he does have a couple of questions about Ridgely Street and the extension. Will that easement be used for truck traffic? Responding to Mr. Hartman, Mr. Heatwole stated that there will be some truck traffic from Ridgley Street, but his understanding is that with the way that this site is functioning now is that most of the truck traffic comes from the Clara Street Extension. Mr. Hartman asked if there are no maintenance plans in affect for maintaining the Ridgely Street easement. Responding to Mr. Hartman, Mr. Heatwole stated that to his knowledge there is no 5 9

Paj 10

Item 1. CITY OF DOVER PLANNING COMMISSION JANUARY 17, 2023 easement maintenance agreement in place. He thinks that one of the things that they have talked about in this process is that they need to get one of those agreements in place. The two properties to the south are undeveloped so that if they develop in some time, they will need to become a party to that easement maintenance agreement as well. Mr. Hartman stated that the next concern that he has is the frontage requirement from the Ordinance. We are required to submit to the City Council a recommendation whether or not waiving this frontage requirement is something that is necessary. He hasn’t seen anything in the application that he can refer to or talk to City Council about why this is needed. There are specific requirements that they ask for would cause extraordinary and unnecessary hardship. Or it wouldn’t be detrimental to public health, safety and general welfare. This is all in the DAC Report, but he doesn’t see a response from the applicant. Responding to Mr. Hartman, Mr. Heatwole stated that the property has limited frontage. They just have a little bit of frontage on Clara Street Extension. They actually don’t own frontage on Ridgely Street. So the hardship is that the property has a lack of frontage; yet, there is more space on the property to develop. Mr. Hartman stated that he just doesn’t see that in writing where City Council can look at it and say this is a fact, this is in writing and is something that we can vote on. Can that be pointed out somewhere? Responding to Mr. Hartman, Mr. Heatwole stated that this plan that is up right now would show that. It identifies that they are 408 feet from Ridgely Street. They are showing Clara Street Extension. and there is about 30 feet of frontage on Clara Street Extension. This plan shows the hardship for the parcel. Mr. Hartman asked if Planning Staff feels that the applicant has met the requirement for the Commission to consider this waiver of the lot frontage. Responding to Mr. Hartman, Mrs. Melson-Williams stated that as part of the DAC Report on Page 11 under the “Recommendations Suggested as Conditions of Approval,” Item #3 is the Planning Staff’s response to this request for a Subdivision Waiver for the requirement for a lot to have frontage on a public street. They find that this property is unique in nature as Mr. Heatwole noted. It has very limited frontage even on Clara Street Extension. On this image it is about 30 feet. There is no other street network that it is adjacent to. It is certainly adjacent to a railroad corridor but that doesn’t count as a public street. They feel that the current access easement that basically continues from the terminus of the right of way of Ridgely Street across adjacent property to this property in this southern area which has been in place for a number of years is likely from the time of development of the “parent building” on the site. That is in place, so it clearly provides access to a public street. There is that other existing access to the Clara Street Extension. This property is like the last property on the end of the street. They are going to do a cross access easement to ensure that even this smaller subdivided parcel continues to be able to cross the large “parent parcel” to be able to get to that public street. This is one of those cases where she thinks that the shape of the property and its relationship to this existing street network is one of reasons why waivers such as this are built into our Code. There is really no other street network for them to take access from or have frontage on because there are other properties that are between them and those street networks. Mr. Hartman stated that Planning Staff agrees that the waiver to create a lot without frontage should be approved. Responding to Mr. Hartman, Mrs. Melson-Williams stated yes. 6 10

Paj 11

Item 1. CITY OF DOVER PLANNING COMMISSION JANUARY 17, 2023 Mrs. Denney asked if ingress/egress is totally on Ridgely Street. Responding to Mrs. Denney, Mr. Heatwole stated that they envision that most of the truck traffic will come from Clara Street Extension. and Mr. Mast who was here tonight could explain that. They anticipate most of the truck traffic coming from that direction because it comes from that direction for the existing warehouse now, not entirely but mostly. Then they would expect employees to use Ridgely Street because it’s easier for cars on that street. He understands that that has more to do with the Route 8 intersection than it does with Ridgely Street itself. In laying out the site, they provided a means for trucks to come in, deliver materials to the site, and then kind of circle back and go around through the easement and back to the Clara Street Extension. The idea was to give vehicles the option in whatever direction they want to go. They feel that the traffic works now for an existing 1 million square foot warehouse; so with adding 40,000 SF, they are confident that it is also going to work. Mrs. Denney stated that primary ingress/egress at this point is the Clara Street Extension. There could be some options with employees and stuff but the biggest thought process lends itself to the trucks. Of course there is a school there but realizing it is separated by the railroad tracks so she is not as concerned about that. She travels that way and goes over in that direction every morning because she drops her grandkids off at school. But she also notes that within that area because of the public school systems there, we do have a lot of youth who are walking and coming and going in that area. She would say that she generally sees them mostly before and after school but kids and tractor trailers, to her, sometimes don’t mix. She just kind of wants to feel assured that that will be the primary ingress/egress for the tractor trailers. Responding to Mrs. Denney, Mr. Heatwole stated yes, that is his understanding. They are going to set the building to kind of front on Ridgely Street (easement). Dr. Jones asked if they are at a point where there may be concerns or any comments from residents. Responding to Dr. Jones, Mrs. Maucher stated that she is getting ready to open the public hearing. Mrs. Maucher opened the public hearing. Ms. Linda Parkowski – Kent Economic Partnership Ms. Parkowski stated that they have been involved with this project. She strongly encourages the Planning Commission to approve. Like everyone said, this is unique property and they don’t have a whole lot of options for where to place it. But this is needed. Warehousing in Dover is needed and this is an industrial area over on Ridgely Street. They support this project. Mrs. Melson-Williams stated that she did want to note that the applicant brought with him this evening, an updated Site Plan diagram that relocated a series of the parking spaces from the west side of the building (which is at the bottom of the page) over to the east side of the building. That would kind of cluster the parking for vehicles on one side of the building and that side of the building being the one closest to the building entry for employees and the public. It was also placed on the desks of the Commissioners this evening. Mrs. Maucher closed the public hearing. 7 11

Paj 12

Item 1. CITY OF DOVER PLANNING COMMISSION JANUARY 17, 2023 Mr. Hartman moved to approve S-23-01 East Carolina Supply Warehouse on Ridgely Street for the Site Development Plan and the Minor Subdivision Plan for a property currently addressed as 631 Ridgely Street, including the Performance Standards Review, the reduction of parking requirements, and the Subdivision Waiver to create a lot without frontage on a public street. He bases the motion to approve the waiver for the lot frontage based on the recommendations of Planning Staff in the DAC Report, Section 11 Subparagraph 3 and comments made during this meeting, seconded by Mrs. Welsh. Mr. Heatwole stated that they have one more waiver for the partial elimination of upright curbing. Responding to Mr. Heatwole, Mrs. Maucher stated that is a function that Staff can grant without Planning Commission approval. Mrs. Melson-Williams stated that the curbing waiver is something that Planning Staff can recommend and take action on. They have done that as part of the Report. The motion was carried 8-0 by roll call vote with Mr. Cooper absent. Mr. Hartman voting yes; based on the DAC Report and the questions and answers revealed tonight. Mr. Baldwin voting yes; based on the previous discussions and Staff recommendation. Dr. Jones voting yes; based upon the previous comments. Mrs. Welsh voting yes; she thinks that it is a great use of the property and a particularly good solution for the frontage on a public street. Mrs. Malone voting yes; for the reasons stated. Mr. Roach voting yes. Mrs. Denney voting yes; for reasons stated as the motion was made. The DAC Report is certainly important to her and she thinks that the waivers, especially the frontage issues are just necessary because to her, they are exceptional practical difficulties because of the lay of the land and the location of the lot. She agrees with comments from Mrs. Malone (Mrs. Welsh) that this is a good use for this particular piece of property. Mrs. Maucher voting yes; based on the DAC recommendations and Planning Staff recommendations. NEW BUSINESS Meeting adjourned at 7:58 PM. Sincerely, Kristen Mullaney Secretary 8 12

Paj 13

Item 2. The Institute for Public Administration presents Advanced Land Use Law COURSE INSTRUCTOR Max Walton, Esq. Connolly Gallagher LLP. March 3, 2023 This course focuses on advanced land use law in Delaware and expands upon the material presented in our introduction to land use law course. 9:00 a.m. to NOON Check-in begins at 8:30 a.m. This course will highlight the recent land use case law from the past year that may affect municipalities statewide. Participants will learn Kent County Levy Court about both national court decisions and Delaware Room 220 court decisions affecting local land use. 555 S Bay Rd, Dover, DE 19901 This session qualifies for credit toward the Certificate in Local Government Leadership and the $55 Registration Fee Certificate for Planning Education. Includes refreshments Registration Deadline Contact Sean O’Neill (oneill@udel.edu) with March 2, 2023 questions about this event. AICP members can earn 3 Certification REGISTER ONLINE Maintenance (CM) credits and 1.5 Law credits for this activity. More information www.bidenschool.udel.edu/ about AICP’s CM program can be found ipa/events/upcoming at www.planning.org/cm. 13

Paj 14

2022 Subdivision Item 3. File # Plan Name Location Type Lots Acreage Action1 SB-22-01 Lands of Four M Investments LLC 1601 POW/MIA Parkway Minor Subdivision Plan 2 37.447 PC Conditional Approval 01/18/22 SB-22-02 Lands of Raul M Juarez 508 Acorn Lane Minor Subdivision Plan 3 2.455 PC Conditional Approval 02/23/22 Lands of Bayroadcap LLC for Landing SB-22-03 Square 600 Bay Road Minor Subdivision Plan 2 12.9366 PC Conditional Approval 04/18/22 SB-22-04 Lands of Iris and William Wilson 838 Forest Street Minor Subdivision Plan 2 0.5429 PC Conditional Approval 09/19/22 SB-22-05 Lands of NCALL 217, 225, and 235 N Kirkwood St Minor Subdivision Plan 5 1.0176 PC Conditional Approval 10/17/22 14

Paj 15

2022 Site Plan Item 3. File # Plan Name Location Zoning Description Review Type Bldg Sq Ft (new) DU Acres Parcels Action1 Action2 S-22-01 Caliber Car Wash 280 Cowgill St C-4 New Car Wash Site Plan 3,500 1 ED-05-077.10-01-17.00-000, Tabled 02/22/22 PC Conditional Approval 04/18/22 S-22-02 Frito Lay Exchange Center 300 Lafferty Lane M, Warehouse and Distribution Facility Site Development Plan, 7,884 23 ED-05-077.16-02-05.00-000, PC Conditional Approval Final Approval 03/21/22 AEOZ Subdivision Plan 03/21/22 S-22-03 El Azteca 801 N State Street C-2A Restaurant PC Review - Site Plan 7,681 2 ED-05-068.09-01-13.00-000, PC Conditional Approval Final Approval 03/21/22 03/21/22 S-22-04 Street Improvements Plan: Raymond Raymond Street/Railroad NA Street Improvements PC Review - Site Plan 2 ED-05-067.00-02-53.00-000, PC Approval 03/21/22 Street & Railroad Avenue Avenue ED-05-067.00-02-56.00-000 S-22-05 Capital Baptist Church - Accessory 401 Kesselring Avenue R-10 Accessory Structure (Storage) Administrative Review 1,800 8 ED-05-085.08-02-02.01-000, Administrative Review Structure (Filed) 03/03/22 S-22-06 Kent County Family Courthouse and 415 and 445 S Governors IO, H Courthouse and Parking garage PC Review - Site Plan and 105,259 4 ED-05-077.09-03-33.00-000, PC Conditional Approval Parking Garage Avenue Architectural Review ED-05-077.09-03-35.00-000, 06/21/22 Certification ED-05-077.09-03-32.00-000, ED-05-077.09-03-36.00-000, ED-05-077.09-03-37.00-000, ED-05-077.09-03-48.00-000, ED-05-077.09-03-50.00-000, ED-05-077.09-03-51.00-000, ED-05-077.09-03-52.00-000, ED-05-077.09-03-61.00-000, S-22-07 Parking Lot at 446 S. Governors 446 S Governors Avenue C-2A Parking Lot PC Review - Site Plan 0 ED-05-077.09-03-21.00-000, PC Conditional Approval Avenue 06/21/22 S-22-08 Delaware Brain and Spine Center: 487 S Queen Street C-1A Parking Lot Administrative Site Review 0 ED-05-077.09-03-03.00-000, Administrative Review Final Approval 06/01/22 Parking Lot Expansion Filed 04/26/22 S-22-09 Dover Apartments South side of Leipsic Road SC-2, Apartment Complex PC Review - Site Plan 46,800 216 15 ED-05-068.05-01-15.01-000, PC Conditional Approval SWPOZ 06/21/22 S-22-10 Lands of Mamie Futrell: Parking Lot 955 Forest St CPO Parking Lot Administrative Site Review 0 ED-05-076.07-01-63.00-000, Administrative Review for Office Filed 06/02/22 S-22-11 Bank at 837 N DuPont Highway 837 North DuPont Highway C-4, Administrative Site Plan Administrative Site Review 3,467 12 ED-05-057.00-01-43.00-000, Administrative Review Final Approval 11/14/22 SWPOZ Filed 08/09/22 S-22-12 DuPont Plaza at 747 N DuPont Hwy 747 N DuPont Hwy SC2 Revised Site Development Master PC Review - Master Plan 52,190 10 ED-05-068.05-01-15.00-000, PC Conditional Approval Revised Master Plan Plan 10/17/22 S-22-13 Garrison Homes LLC - Warehouse at 119 Rosemary Road and 110 M, Site Development Plan PC Review - Site Plan 17,485 2 ED-05-077.16-02-12.02-000, PC Conditional Approval 119 Rosemary Rd Lafferty Lane AEOZ ED-05-077.16-02-12.01-000 11/21/22 S-22-14 Commerce Way Dover DE LLC: 165 Commerce Way IPM Site Development Plan PC Review - Site Plan 234,000 23 ED-05-076.10-02-07.03-000, PC Conditional Approval Warehouse at 165 Commerce Way 12/19/22 S-22-15 Lafferty Lane Secure Storage on Lafferty Lane: Lots 2, 3, IPM Site Development Plan Administrative Site Review 68,600 ED-05-077.00-01-25.01-000, Admin Review Filed and 4 ED-05-077.00-01-25.02-000, 11/09/22 ED-05-077.00-01-25.03-000 S-22-16 Retail Store Dollar General at 293 293 South Saulsbury Rd C-2A, Site Development Plan PC Review - Site Plan 14,886 4 ED-05-076.11-01-43.00-000, PC Conditional Approval South Saulsbury Road (with Royal COZ-1 12/19/22 Farms) 15

Paj 16

2022 Rezoning Item 3. File # Applicant Location Zfrom Zto Acres Parcels Ordinance Action1 Action2 Action3 Z-22-01 Lands of State of Delaware at S Governors 411/429/435/441/447 S IO IO/H 1.74 ED-05-077.09-03- 2022-02 CC First Reading PC Approval CC Approval Avenue and W Water St: Rezoning to H Governors Avenue & 117 W Water 37.00-000, ED-05- 2/28/2022 3/21/2022 3/14/2022 Street 077.09-03-48.00-000, ED-05-077.09-03- Z-22-02 Part of Lands of Calvary Baptist Church at Part of 2285 Forrest Avenue R-10/COZ-1 RM-2/COZ-1 25 ED-05-075.00-01- 2022-11 CC First Reading PC Approval CC Approval 2285 Forrest Ave: Rezoning of 25 acres 06.00-000 9/12/2022 9/19/2022 10/10/2022 Z-22-03 Lands of Silver Linings Holding Corp 630 W Divisions Street C-3/COZ-1 C-2A/COZ-1 1.0853 ED-05-076.08-01- 2022-12 CC First Reading PC Approval CC Approval 40.01-000, ED-00- 9/26/2022 10/17/2022 11/14/2022 056.00-01-41.00-000, 16

Paj 17

2022 Misc Item 3. File # Plan Name Location/Topic Type Ordinance Action1 Action2 MI-22-01 Intergovernmental Coordination with Town Consultation with Adjacent Town on Staff Review and Consultation Letter Letter of No Objection to of Wyoming on Comprehensive Plan their Comprehensive Plan Comprehensive Plan 03/01/22 MI-22-02 Redistricting of City Council Districts City of Dover Reapportionment of Council Districts Staff Analysis and CC Adopted following 2020 Census Preparation of Draft Ordinance Map of Council Districts 11/14/22 Spring 2022 MI-22-03 Lands of Barbara M. Cummings 311 and 319 Wyoming Avenue Minor Lot Line Adjustment Staff Approval of Record Plan 09/01/22 MI-22-04 Lands of Blue Hen Mall LLC & Bayhealth 655 Bay Road Minor Lot Line Adjustment Staff Approval of Record Properties LLC Plan 07/06/22 MI-22-05 Text Amendment: IPM2 Zone Zoning Ordinance Amendment to Zoning Ordinance, Article 3 2022-21 PC Recommended CC Approved Section 20A. IPM2 to revisions to Approval 11/28/22 12/19/22 permitted and conditional uses, purpose statement 17

Paj 18

2022 Historic Item 3. File # Plan Name Location Type Parcels Action1 Action2 HI-22-01 Referral of Fence Permit #21-1556 at 506 S. State 502-506 S. State Street & 100 W. Water Fence Permit ED05-077.09-03-70.00-000 HDC Recommended Approval of HDC Recommended St Street Architectural Review Certification Approval of for 6 ft. black aluminum picket style Architectural Review fence 01/20/22 Certification for 6 ft. black aluminum picket style fence 01/20/22 HI-22-02 Lands of State of Delaware at S Governors 411/429/435/441/447 S Governors Ave & Rezoning properties to the H (Historic ED05-077.09-03-37.00-000, ED- HDC Recommended Approval to HDC Recommended Avenue and W Water St: Rezoning to H 117 W Water Street District Zone) 05-077.09-03-48.00-000, ED-05- include 6 properties in the H zone, Approval to include 6 077.09-03-50.00-000, ED-05- the base Zone IO not to change. properties in the H 077.09-03-51.00-000, ED-05- 03/17/22 zone, the base Zone IO 077.09-03-52.00-000, ED-05- not to change. 077.09-03-61.00-000 03/17/22 HI-22-03 Kent County Family Courthouse & Parking Garage East side of S Governors Ave between Site Plan Review for Architectural Review ED05-077.09-03-33.00-000, ED- HDC Recommendation of Approval HDC Recommendation Bank Lane and W Water St: 415 and 445 S Certification 05-077.09-03-35.00-000, ED-05- for Architectural Review of Approval for Governors Avenue 077.09-03-32.00-000, ED-05- Certification with Conditions Architectural Review 077.09-03-36.00-000, ED-05- 04/21/22 Certification with 077.09-03-37.00-000, ED-05- Conditions 04/21/22 077.09-03-48.00-000, ED-05- 077.09-03-50.00-000, ED-05- 077.09-03-51.00-000, ED-05- 077.09-03-52.00-000, ED-05- 077.09-03-61.00-000, ED-05- 077.09-03-53.00-000 HI-22-04 Referral of Permit #22-661 at 527-529 S. State 527-529 S State Street Permit for Parking Improvements ED05-077.09-05-47.00-000 HDC Recommended Approval of HDC Recommended Street Architectural Review Certification Approval of subject to conditions on screening Architectural Review 05/19/22 Certification subject to conditions on screening 05/19/22 HI-22-05 Delaware Public Archives: Consultation on Roof 121 Martin Luther King Jr Blvd N Roof Project Consultation ED05-077.09-05-13.00-000 HDC made recommendation on roof HDC made Project material options 05/19/22 recommendation on roof material options 05/19/22 HI-22-06 Referral of Permit #22-1298 at 43 The Green 43 The Green, John Bell House Accessory Structure (Restroom & Storage ED05-077.09-05-28.00-000 HDC Recommended Approval of HDC Recommended Space) Architectural Review Certification Approval of with reduction of rear setback Architectural Review 08/18/22 Certification with reduction of rear setback 08/18/22 HI-22-07 Referral of Demolition Activities at 235-239 W. 235-239 West Loockerman St Update on Dangerous Building ED05-077.09-03-35.00-000 HDC made Determination of HDC made Loockerman St Designations and Demolition Activities Demolition by Neglect and Determination of Recommendations for continued Demolition by Neglect evaluation of building; Superseded and Recommendations by City Council declaration as for continued Dangerous Building 10/20/22 evaluation of building; Superseded by City Council declaration as Dangerous Building 10/20/22 18

Paj 19

2022 Conditional Use Item 3. File # Plan Name Location Zoning Type Bldg Sq Ft DU Primary Tax Parcel Action1 (new) C-22-01 Kind Kids Early Learning Center 725 Walker Road C-1A Child Daycare Center 4,729 ED-05-067.15-05-34.00-000 PC Conditional Approval 01/24/22 C-22-02 Apartment 773 S. Queen Street CPO Apartment 3,864 1 ED-05-077.13-01-30.04-000 Withdrawn at Request of Applicant 02/15/22 C-22-03 Lands of Chiang & Sons Properties 1241 College Park Dr CPO Office with Apartments on 2nd 11,700 9 ED-05-067.00-02-12.08-000 Denied by PC 08/19/22 LLC Office/Retail and Apartments floor 19

Paj 20

2022 Annexations Item 3. File # OrdNo Plan Name Location County City Zoning Lots Acreage Parcel Action1 Action2 Zoning AX-22-01 2022-01 Lands of Ernestine F Huff 166 Mifflin Road RS-1 R-8 1 0.574 ED-00-076.14-01-02.00-000 PC PC Recommended Approval Approval 02/22/22 02/09/22 AX-22-02 2022-19 Lands of Ditko Properties LLC 1107 S Bradford St RM C-2A 1 0.2582 ED-00-076.14-01-02.00-000 PC PC Recommended Approval Approval 11/21/22 11/09/22 AX-22-03 2022-25 Lands of Craig, Keller, & Burkett 57 Rocky Road, 4085 W AR, RM RM-2 3 40.1157 ED-00-056.00-01-40.00-000, First Reading PC Denneys Rd, 1.9662 Acres W SWPOZ ED-00-056.00-01-41.00-000, before City Approval Denneys Road ED-00-056.00-01-42.00-000 Council 12/19/22 11/14/22 20

Paj 21

Item 4. City of Dover DATA SHEET FOR SITE PLAN REVIEW DEVELOPMENT ADVISORY COMMITTEE MEETING OF February 8, 2023 PLANNING COMMISSION MEETING OF February 21, 2023 Plan Title: NeighborGood Partners Division Street Office at 223 W. Division Street, S-23-03 Plan Type: Site Development Plan Location: North side of West Division Street, east of North New Street Address: 223 West Division Street Tax Parcel: ED-05-076.08-05-29.00-000 Owner/Applicant: NCALL, Inc. Site Area: 5,120 SF +/- total Zoning: C-1A (Limited Commercial Zone) Previous Use: Commercial, Apartments (two buildings demolished) Proposed Use: Office Building Building Area: 6,226 SF Parking Required: 0 spaces Parking Proposed: 3 spaces Sewer & Water: City of Dover Waivers Requested: Consideration of a Tree Mitigation Plan Elimination of Upright Curbing requirements 21

Paj 22

Item 4. S-23-01 NeighborGood Offices at 223 West Division Street DAC Report of February 8, 2023 Page 2 City of CITY OF DOVER Dover Planning DEVELOPMENT ADVISORY COMMITTEE Office APPLICATION REVIEW COMMENTARY D.A.C. MEETING DATE: February 8, 2023 APPLICATION: NeighborGood Partners Division Street Office at 223 West Division Street FILE #: S-23-03 REVIEWING AGENCY: City of Dover Planning CONTACT PERSON: Julian Swierczek AICP, Planner II PHONE #: (302) 736-7196 I. PLAN SUMMARY This Application is for review of a Site Development Plan Application to permit construction of a two-story 6,226 SF office building and associated site improvements. The property is zoned C- 1A (Limited Commercial Zone). The property is located on the north side of W. Division Street, east of N. New Street. The owner of record is NCALL, Inc. Property Address: 223 W. Division Street. Tax Parcel: ED-05-076.08-05-29.00-000. Council District 4. Previous Applications Application #V-19-04 had sought two variances for this site and was approved by the Board of Adjustment at their April 2019 meeting. Both variances were from the requirements of Article 4 §4.14 of the Zoning Ordinance pertaining to the bulk standards in the C-1A (Limited Commercial Zone) in order to allow for an increase in both the maximum building height in feet and number of stories. Site Development Plan Application and associated Lot Consolidation Plan Application S-19-13 had then come before the Planning Commission at their July 15, 2019 meeting. This previous iteration of the Site Development Plan had utilized the approved Variances and proposed a three- story, 7,671 SF Office Building along with two Waiver Requests. The first was for a Tree Mitigation Plan in order to provide the required tree plantings at two other addresses that NCALL had proposed to develop; and the second was for the elimination of Upright-Curbing. Both Waivers were approved in conjunction with the conditional approval of the Site Development Plan Application and associated Lot Consolidation Plan. This Plan then came before the Planning Commission again in November of 2020 to advise of revised project design with the building reduced to two stories. The Plan was granted a one-year extension of Planning Commission Approval at their May 2021 meeting, which extended the Planning Commission approval through to July 31, 2022. Final Plan Approval was issued in a Letter dated May 27, 2022, and the Lot Consolidation Plan was recorded in June of 2022. However, no permits were filed by July 31, 2022 and Planning Commission Approval therefore expired. 22

Paj 23

Item 4. S-23-01 NeighborGood Offices at 223 West Division Street DAC Report of February 8, 2023 Page 3 II. PROJECT DESCRIPTION This is a Site Development Plan Application to develop the property currently addressed as 223 West Division Street. The Lot Consolidation which was associated with the previous Application associated with this Site was Finalized and Recorded in June of 2022 consolidating the properties addressed as 223 and 225 West Division Street. The current property addressed as 223 West Division consists of 5,120 SF +/-. The Site Development Plan shows one main structure to be utilized as an office building for NeighborGood Partners, along with associated site improvements. The property is located on the northeast corner of West Division Street and North New Street. Along West Division Street to both the east and west are properties also zoned C-1A, containing a mix of uses, primarily residential uses including one-family residences which are a permitted use in the zone, as well as a church which is a nonconforming use in the zone. The properties to the north along North New Street are zoned RG-1 (General Residence Zone) and contain primarily one-family residences. The applicant has noted two waiver requests on their plans. The first is a Waiver Request from the Zoning Ordinance, Article 5 §16.62 for the tree density requirements, asking that they instead be permitted to plant the required two (2) trees on other properties of theirs in the City. The second Waiver Request asked for by the applicant is from the requirements of Article 6 §3.6(b) requiring that all permanent parking areas shall be enclosed with upright concrete curbing at least six inches in height. The applicant has stated that this waiver is needed to better facilitate stormwater management. Bollards are proposed in the parking spaces adjacent to the building. III. ZONING REVIEW C-1A (Limited Commercial Zone) and Lot & Bulk Standards The development site is zoned C-1A (Limited Commercial Zone) and is subject to the regulations of Zoning Ordinance, Article 3 §12 and Article 4 §4.14. Business, professional, and governmental offices are listed as a permitted use in the C-1A zoning district. Article 7 §1.3 permits the reconstruction or enlargement of a building to utilize its legal non- conforming bulk standards so long as said reconstruction or enlargement does not increase the degree of or create any new nonconformity. It is with the established legal non-conforming bulk standards of the site that the Applicant is proposing the placement of this new building. It is noted that the Variances which were approved in conjunction with the previous Site Development Plan for this property (S-19-13) included increasing the maximum permitted number of stories from two (2) to three (3), and the maximum permitted building height from 30 feet to 34 feet. As this previous Plan has expired without these approved Variances having been utilized, the Variances have also expired, and this increased Building Height would no longer be permitted. It is noted that the previous iteration of this project had initially been presented to the Planning Commission as 3-stories and 34 feet in height. As such, the Project was required to go before the Board of Adjustment where Variances to establish an increase in both the maximum building height permitted in the C-1A Zone in feet (30 ft. to 34 ft); as well as the maximum number of stories permitted in the C-1A Zone to from two (2) stories to three (3) stories. The Board of 23

Paj 24

Item 4. S-23-01 NeighborGood Offices at 223 West Division Street DAC Report of February 8, 2023 Page 4 Adjustment approved both Area Variance Requests at their April 2019 meeting. The Design had however been revised, and the Variance approvals have since expired. The standards for C-1A are provided below: Table 1: Required and Proposed Bulk Standards C-1A (Limited Commercial Applicant's Project Zone) Lot area - 5,120 SF Lot width (ft.) 25 64 Lot depth (ft.) - 80 Front yard (ft.) 25 4.6/ 3.8 None but 5 ft. minimum if Side yard (ft.) 4.0 provided Rear yard (ft.) 15 19 Side or rear yards which adjoin a 15 19 Residence zone (ft.) Off-street parking spaces Per 300 sq. ft. floor area or - 3 Per employee (whichever is greater) - 3 Maximum permitted: Building height Stories 2 2 Feet 30 *34 Floor area ratio 1.5 0.610 *34 feet is the noted building height in the Plan submitted which does not comply with the Bulk Standards of the C-1A Zone. The Applicant has however verbally indicated that the building is to be 28.5 feet in height and the Plans will be revised accordingly. IV. PARKING SUMMARY The C-1A zone (as noted above in Table 1) does not have a parking requirement, nor does the Zoning Ordinance contain any added parking requirements for the use of an Office. The applicant is however proposing to provide three (3) parking spaces at the rear of the building, to be accessed directly off the rear alley. Bicycle Parking Bicycle parking is required at a ratio of one (1) space for every twenty (20) parking spaces. Based on the proposed three (3) regular spaces, one (1) bicycle parking space must be provided. The plan indicates that bicycle parking rack with three (3) spaces is to be provided. 24

Paj 25

Item 4. S-23-01 NeighborGood Offices at 223 West Division Street DAC Report of February 8, 2023 Page 5 V. SITE CONSIDERATIONS Site Entrance Vehicular access to the site will only be possible at the rear of the building where the applicant is proposing three (3) new parking spaces which are directly accessed via the rear unnamed alley. No new drive aisles on the site or entrances off West Division Street or North New Street are proposed. Pedestrian Considerations The site is currently served by existing frontage sidewalk along both West Division Street and North New Street. The primary pedestrian access appears to be from North New Street, where two (2) sidewalks are proposed connecting the two doors on this frontage to the public sidewalk. There are additional doors proposed on the north and east sides of the building. There is no proposed door on the West Division Street frontage. Lighting Article 5 §7.1 stipulates that lighting shall provide no less than 1.5 footcandles at grade. Light shall also be deflected away from adjacent residential areas and shall not be distracting to traffic on adjacent roads. The plans do not include any details of the proposed lighting plan; however, the applicant anticipates building wall-mounted light fixtures will be implemented. There is existing street lighting at this intersection. Waiver Requested: Elimination of Upright Curbing The Zoning Ordinance, Article 6 §3.6(b) requires upright curbing for all parking areas and access drives. The plan does not include curbing for the parking lot area at the rear. The Plans note a written waiver request for the elimination of curbing for consideration by the City Planner. The Waiver Request submitted does note that bollards will be utilized so to ensure vehicles remain a safe distance from the building. Dumpsters Article 5 Section 6.12 requires that an office building of less than 50,000 SF provide a minimum of two (2) dumpsters for the first 16,000 SF of gross floor area, and one (1) additional dumpster for each additional 16,000 SF of gross floor area thereafter. As the building is proposed to be 6,226 SF a minimum of two (2) dumpster units will need to be provided. The Plans submitted note a feature labeled as “Trash Container Storage” to the rear (north) of the proposed building facing the alley. The number of dumpsters is not identified. A Dumpster enclosure is required to screen the dumpster from view whenever these units are situated so that they will not be visible from any public right-of-way or from an adjacent property, as identified in Article 5 Section 6.11. A Dumpster Enclosure is shown on Site Plan Sheet, with details provided showing that it is to be built of masonry and will provide an opaque fence for dumpster enclosure access. Signage A separate Sign Permit application is required to be submitted for review prior to the installation of signage on the property pertaining to the building/site. 25

Paj 26

Item 4. S-23-01 NeighborGood Offices at 223 West Division Street DAC Report of February 8, 2023 Page 6 VI. BUILDING ARCHITECTURE The applicant has submitted an architectural rendering of the building depicting the structure as viewed from the southwest of the building looking northeast towards the building. The office building is two-stories in height, with an overhanging, gabled roof above. The main entrance appears to be on the North New Street elevation. The façade appears to be composed mostly of red brick. This brick is depicted covering the entire first floor on both the North New Street (west) and West Division Street (south) elevations. The wall space in between the 1st and 2nd floors is also shown covered in red brick, but with a decorative scheme of a darker colored brick placed creating a decorative, geometric pattern horizontally across both elevations. The second floor of the building is primarily clad in horizontal white siding. The doors and windows are black complementing the black roof above. There is an awning over the main entrance to the west. No depiction of the north or east facades are provided. VII. TREE PLANTING AND LANDSCAPE PLAN One (1) tree is required for every 3,000 SF of land area. This project site consists of a total lot area of 5,120 +/- SF which would require two (2) trees to be planted. No trees are shown to be planted on-site as there is little pervious surface available. Request for Consideration of Tree Mitigation Plan Article 5 § 16.91(a) allows the Planning Commission to grant a waiver to mitigate the trees required to be planted to achieve tree density requirements. The previous iteration of this Plan (Site Development Plan S-19-13) was approved with a Tree Mitigation Plan noting that one (1) additional tree would be provided at both 218 and 228 North Kirkwood Street. The Plans submitted with this current Application note the Tree Mitigation as approved previously but does not clearly provide documentation to confirm that these trees were planted at those addresses. This is also a Letter dated January 5, 2023 from the applicant noting tree plantings at 26 and 28 N. Kirkwood Streets as Tree Mitigation. Planning Staff will work with the applicant to confirm that these tree plantings did in fact occur at specific off-site properties, and that these trees are additional to those required for the development of those properties themselves or if new Tree Planting locations need to be identified. It is noted that each of the above referenced properties were proposed to be redeveloped as one- family-detached dwelling units (single-family homes). Such development is required to provided landscaping and tree plantings specific to those properties and their respective developments. Any information or documentation provided by the Applicant to confirm that these additional trees were planted at the aforementioned properties must also show that these additional trees were not counted toward the tree planting requirements of the respective addresses. Furthermore, Article 5 §15 of the Zoning Ordinance describes the landscape requirements for a new application, which are to be followed unless it can be demonstrated through the Site Plan review process that such features would be impractical or incompatible with a particular land use or site development proposal. The applicant has not submitted a landscape plan due to the limited availability of open space on the site for planting. However, the Site Plan showing the proposed project should identify what is intended for any area of the site that isn’t impervious. 26

Paj 27

Item 4. S-23-01 NeighborGood Offices at 223 West Division Street DAC Report of February 8, 2023 Page 7 VIII. CITY AND STATE CODE REQUIREMENTS The subject proposal has been reviewed for code compliance, plan conformity, and completeness in accordance with this agency’s authority and area of expertise. The following items have been identified as elements which need to be addressed by the applicant: 1) The Parcels previously addressed as 223 & 225 W. Division Street have been consolidated per the Final Plan Approval of Site Development Plan S-19-13. Recordation of the Lot Consolidation associated with the approved Site Development Plan was achieved on June 8, 2022. The Property Address for this Site is now 223 West. Division Street. Remove any reference to 225 W. Division Street, as well as any mention of a second parcel. 2) Building is referenced several times as being 34 feet. This was the building height noted with a previous version of the design at three (3) stories. Revise the Building Height for the current two (2) story design, noting that the maximum Building Height permitted in the C-1A (Limited Commercial Zone) is 30 feet. 3) The Site Plan must be updated with changes recommended or approvals including any waivers granted by the Planning Commission. Add to plan as reference notes. 4) The tree planting requirement shall be provided in accordance with the Zoning Ordinance unless a waiver is granted by the Planning Commission approving a Tree Mitigation Plan. A note was provided on the Site Plan referencing the previous approval of a Tree Mitigation Plan as was submitted with Application S-19-13 which has since expired. A separate Letter identified two other property addresses as the tree planting location. It is noted that the two properties referenced as having each received tree plantings must have trees present that are in addition to those required with the respective development of those properties themselves. Provide documentation to verify these tree plantings or propose new Tree Mitigation planting locations. 5) Sheet 1/Cover Sheet: a) Data Column i) Remove “225” under the Property Address, as the property is addressed as 223 W. Division Street. ii) For Item #9, provide the overall Building square footage. iii) Verify the Floor Area Ratio. iv) Bicycle Parking is referenced twice in the Data Column. Remove one of these references. v) The Maximum Building Height permitted in the C-1A (Limited Commercial Zone) is 30 feet. vi) For Item #24, remove “N/A” and provide the Tree Density Calculations both as required and proposed. Note the Tree Mitigation Plan as approved per the previous Site Development Plan S-19-13, noting the addresses. vii) For Item #25, remove the reference to there being Two (2) Existing Lots, as these Lots have been consolidated. b) Remove the Notation referencing the Board of Adjustment taken on Variance Application V-19-04. This Variance has since expired, and the Project is no longer 27

Paj 28

Item 4. S-23-01 NeighborGood Offices at 223 West Division Street DAC Report of February 8, 2023 Page 8 proposing development which would necessitate utilizing these Variances. c) Note the Bulk Standards as required and proposed. Note too that the bulk standards proposed are not increasing the degree of non-conformity as permitted per Article 7, Section 1.3 of the Zoning Ordinance. d) Under “List of Required Regulatory Approvals,” note that there is also the City of Dover Department of Water/ Wastewater. e) Include a note that the Previous Site Development Plan Application S-19-13 included a Lot Consolidation Plan which was recorded June 8, 2022. 6) Provide the Existing Conditions and Demolition Plan. 7) Please submit an Implementation Plan (or clarifying information) for the proposed off-site tree planting. The trees must be new plantings and must be planted in addition to any trees that would normally be required for the off-site properties’ development. IX. RECOMMENDED ADDITIONAL CONSIDERATIONS TO MEET CODE OBJECTIVES In accordance with the Zoning Ordinance, Article 10 §2.2, the Planning Commission in considering and acting upon Site Development Plans may prescribe appropriate conditions and safeguards so that the public health, safety, and welfare, the comfort and convenience of the public in general, and the residents of the immediate neighborhood in particular shall be taken into consideration. These safeguards may to the maximum extent possible further the expressed intent of the Zoning Ordinance and the accomplishment of several objectives in particular listed in subsections 2.21 to 2.28. 1) Waiver Requested: Elimination of Upright Curbing: In accordance with Article 6 §3.6(b) related to the requirement for upright curbing, Staff has approved the request to eliminate the upright curbing requirement for the office building. Staff acknowledges that the applicant is proposing to install bollards to prevent any damage to surrounding infrastructure, and that curbing is thought to interfere with the planned conveyance of stormwater runoff. 2) Waiver Request and Consideration of Tree Mitigation Plan: Staff recommends conditional approval of the Tree Mitigation Plan thus allowing for the required tree plantings to be planted at off-site locations in the City of Dover. The locations identified for these off-site tree plantings are properties to be developed by NeighborGood Partners. If these plantings have been carried out, documentation must be provided confirming this. If the trees have not yet been planted or is otherwise no longer practical, then alternate addresses must be identified/clarified. Staff notes the difficulty planting on this site due the limited amount of pervious areas available for suitable planting due to the impervious surface coverage of the site. a) The Plans must note the proposed sites of the tree mitigation. b) Additional comments on the specific proposed off-site planting location may be issued upon submission of an implementation plan for review. Other agencies may recommend additional considerations to meet code objectives in accordance with their areas of expertise. Action on all considerations identified in this section and by other agencies is at the discretion of the Planning Commission. 28

Paj 29

Item 4. S-23-01 NeighborGood Offices at 223 West Division Street DAC Report of February 8, 2023 Page 9 X. ADVISORY COMMENTS TO THE APPLICANT 1) The Planning Commission should act upon the request for waivers as part of any motion regarding this project application, or as a separate motion as necessary. Note: All waivers are at the discretion of the Planning Commission. The Commission may approve or deny waiver requests. 2) In the event that major changes and revisions to the Site Development Plan occur in the finalization of the Plan, contact the Planning Office. Examples include reorientation of the building, relocation of site components like stormwater management areas and site entrances and increases in floor area. These changes may require resubmittal for review by the Development Advisory Committee, Planning Commission, or other agencies and commissions making recommendations in regards to the plan. 3) In the event that there are changes to the architecture, building footprints, layout or square footage of the building contact the Planning Office. These changes may require review by the Planning Commission. 4) Other agencies and departments which participate in the Development Advisory Committee may provide additional comments related to their areas of expertise and code requirements. 5) Following Planning Commission approval of the Site Development Plan, the Plan must be revised to meet all conditions of approval from the Development Advisory Committee or as otherwise noted. 6) For building new construction, the requirements of the building code and the fire code must be complied with. Consult with the Chief Building Inspector and City of Dover Fire Marshal for these requirements. The resolution of these items may impact the site design including such items as building dimensions and height, building openings, and fire protection needs, parking requirements, etc. 7) The applicant/developer shall be aware that prior to any ground disturbing activities on the site the appropriate Site Plan approvals, Pre-Construction meetings, site inspections and permits are required. 8) Construction may have an effect on the adjacent property owners. Any work requiring the closing or rerouting of residents or visitors should be coordinated as to offer the least amount of inconvenience. 9) The applicant shall be aware that Site Plan approval does not represent a Building Permit, Demolition Permits, and associated construction activity permits. A separate application process is required for issuance of a Building Permit from the City of Dover. If you have any questions or need to discuss any of the above comments, please call the above contact person and the Planning Department as soon as possible. 29

Paj 30

Item 4. CITY OF DOVER DEVELOPMENT ADVISORY COMMITTEE APPLICATION REVIEW COMMENTARY STAFF D.A.C. MEETING DATE: FEBRUARY 1, 2023 APPLICATION: NeighborGood Partners Division Street Office at 223 West Division Street FILE #: S-23-03 REVIEWING AGENCY: City of Dover Department of Public Works and Water & Wastewater CONTACT PERSON: Jason A. Lyon, P.E., Director of Water & Wastewater / Engineering Services CONTACT PHONE #: 302-736-7025 CONTACT PHONE #: jlyon@dover.de.us T HE S UBJECT P ROPOSAL HAS BEEN R EVIEWED FOR C ODE C OMPLIANCE , P LAN C ONFORMITY AND C OMPLETENESS IN A CCORDANCE WITH THIS A GENCY ’ S A UTHORITY AND A REA OF E XPERTISE . T HE F OLLOWING I TEMS HAVE BEEN I DENTIFIED AS E LEMENTS W HICH N EED TO BE A DDRESSED BY THE A PPLICANT : CITY AND STATE CODE REQUIREMENTS SANITATION 1. Every commercial customer shall provide such premises with a sufficient number of solid waste containers to provide adequate capacity for the solid waste placed out for collection without overloading the capacity of the containers. The City of Dover shall provide commercial customers with a maximum of two (2), 90-gallon trash containers and two (2), 90-gallong recycling containers. 2. Trash collection site shall be oriented for side-loading pick-up if customer is utilizing City of Dover sanitation services. 3. Any commercial customer requiring more containers, or larger containers, than provided above, must utilize private service. STORMWATER 1. Final site plan approval will not be granted until a copy of the approved Stormwater/Erosion and Sediment Control Plan from Kent Conservation District / DNREC is submitted to our office. 2. The size, length, slope, type and flow directions must be shown on all existing and proposed storm sewer lines. Rim and invert elevations must be labeled on all stormwater structures. 3. It shall be unlawful for any person to tap or to have tapped any public storm sewer without a permit from the city manager. STREETS 1. Final site plan approval will not be granted until a copy of the approved entrance plan, signed by DelDOT is submitted to our office. 2. The current City of Dover standard street section provides for a 3’ grass strip between the curb and sidewalk. This standard was administratively revised to meet ADA and FHA compliance with cross slope requirements and to prevent cars from scrapping at driveways. The revised standard utilizes a five feet (5’) wide public sidewalk with a five feet (5’) wide grass strip behind the curb. WATER 30

Paj 31

Item 4. NeighborGood Division Street Office at 223 West Division Street File #: S-23-03 February 1, 2023 Page 2 of 4 1. All water utility components must meet the requirements of the Water Wastewater Handbook, effective date March 22, 2010. Please contact our office for more information. 2. The following notes must be added to the plans: a. Hydrant connections by the contractor are prohibited. This method may not be utilized during any phase of the project. b. Any existing water lines not to be utilized by the proposed facility must be properly abandoned at the mains in accordance with the City of Dover Department of Water & Wastewater specifications and requirements. c. The site contractor shall contact the City of Dover Department of Water & Wastewater Construction Manager at (302) 736- 7025 prior to the start of construction. A representative from the City of Dover Department of Water & Wastewater must observe and approve all City owned water and sanitary sewer interconnections and testing. All water taps must be performed by a City of Dover approved contractor. The proposed location for the water connection may need to be adjusted in the field due to conditions of the existing main. Possible conditions that would require tapping relocation include proximity to pipe joints, other taps, concrete encasements, conflict with other utilities, and the like. Test holes must be performed by the contractor to determine the best tapping location. The City of Dover will not be held responsible for field conditions requiring adjustment of the tapping location or for any work required by the contractor to make an appropriate and lawful connection. 3. The size, type, and location of all proposed and existing water lines and valves must be shown on the plan. 4. Water usage projections (peak demand or plumbing fixtures) must be submitted to our office to correctly determine the size of the domestic and irrigation (if applicable) water meter for the proposed building. These projections must be submitted prior to approval so the meter size can be placed on the final site plan. The proposed water meter must be installed in a pit per City of Dover requirements and manufacturer’s recommendations. Also, a dual check valve is required downstream of the meter. 5. The domestic service, fire main connection and valves must be clearly shown for each building. A valve must be installed at the tee to isolate combined fire and domestic water service to the building from the water loop. Typically, this valve is installed at the tee or an acceptable distance from the building. A valve must be provided on the domestic water service, which must be tapped off of the combined eight-inch (8”) fire/domestic service outside of the building. The domestic water tap and valve should be as close to the building as possible. Typically, the domestic tap and valve are located within five feet (5’) to ten feet (10’) of the building. A blow up detail of this layout is recommended. 6. Provide a construction detail for the proposed restraining system for the fire main located within the buildings. The Department of Public Works will test and inspect all fire mains to a blind flange located inside the buildings. The blind flange with tap is used for hydrostatic pressure testing (200 psi for two (2) hours) and dechlorination. The flange must be restrained in the direction of the pipe entering the facility. A pipe entering horizontally through a wall sleeve shall be restrained with rods through the wall. A pipe entering vertically through a slab shall be restrained through the floor to the ninety degree (90 ) bend and thrust block. All rods shall be a minimum of ¾” all thread. All pipes through walls and slabs must be Class 52 cement lined ductile iron pipe. Confirm particulars to meet this requirement with mechanical designer. 7. Water services shall be either type K copper or SDR-9. 8. On October 24, 2022, City of Dover Council approved the new Cross Connection Control Program. This program requires certain backflow prevention assemblies on water service connections to the city’s distribution system. This project will require a double check valve assembly to be installed downstream of the water meter in the building. WASTEWATER 1. All wastewater utility components must meet the requirements of the Water Wastewater Handbook, effective date March 22, 2010. Please contact our office for more information. 2. The following notes must be added to the plans: a. Any existing sanitary sewer lines not to be utilized by the proposed facility must be properly abandoned at the mains in accordance with the City of Dover Department of Water & Wastewater specifications and requirements. b. Part II, Chapter 180, Article III, Section 180-10 of the Code of Kent County requires that “no person shall discharge or cause to be discharged any stormwater, surface water, uncontaminated groundwater, roof runoff, subsurface drainage, uncontaminated noncontact cooling water or unpolluted industrial process waters to any sanitary sewer”, this shall include condensate. Sec. 110-231 of the City of Dover Code defines storm sewer as “…any system used for conveying rain water, 31

Paj 32

Item 4. NeighborGood Division Street Office at 223 West Division Street File #: S-23-03 February 1, 2023 Page 3 of 4 surface water, condensate, cooling water or similar liquid wastes, exclusive of sewage.” The contractor, developer, owner and designers shall ensure during construction that no illegal discharges to the sanitary sewer system are created with the site improvements. 3. The size, length, slope, type and flow directions must be shown on all existing and proposed sanitary sewer lines. Rim and invert elevations must be labeled on all sanitary structures. 4. Cleanouts must be installed on sanitary sewer laterals within five feet (5’) of the building, one foot (1’) outside of the right-of- way and at all bends. Any cleanout located within a traffic bearing location shall be installed with a heavy duty cast iron frame and cover to prevent damage to the cleanout and lateral. 5. Sizing (flow) calculations must be submitted for all sanitary sewer laterals (other than for single-family dwellings) showing that velocity and all other requirements are met. 6. The minimum size of all sanitary sewer laterals shall be six-inch (6”). 7. If kitchen facilities are proposed a minimum 1,000 gallon, two chamber grease trap, meeting all Kent County ordinance requirements, must be provided. A construction detail for the proposed grease trap, as well as the proposed location, must be provided on the plan. 8. Sanitary sewer laterals shall be connected directly to the main, not manholes, unless impracticable, as determined by the Department of Water & Wastewater. GENERAL 1. All existing utilities shall be adjusted to final grade in accordance with current City of Dover requirements and practices. This must be included as a note on the plan. 2. No trees may be planted within ten feet (10’) of utility infrastructure. 3. No structure may be installed within ten feet (10’) of utility infrastructure, please depict all underground utilities and structures on the utility plan sheet to confirm compliance. 4. The final site plan must be submitted in the following compatible digital formats: a. AutoCAD 2018 (.dwg format). b. Adobe Reader (.pdf format). RECOMMENDATIONS SUGGESTED AS CONDITIONS OF APPROVAL TO MEET CODE OBJECTIVES STREETS 1. Please provide a turning diagram for the vehicles entering the parking area from the alley. SANITATION / STORMWATER / WATER / WASTEWATER / GENERAL 1. None. ADVISORY COMMENTS TO THE APPLICANT WATER 1. The City of Dover water system is available to this site. The developer is responsible for all costs associated with extending and providing service to the proposed development. 2. Prior to plan approval, the water system plans must be submitted to the Division of Public Health, Office of Drinking Water for review and approval. The owner/developer will be responsible for providing all completed forms and plan sets to the City of Dover as required for submission to the Office of Drinking Water. Plans will not be submitted to the Office of Drinking Water until review has been completed by our office. 3. Hydrant flow testing is currently only performed during the spring and fall. The applicant must call the Department of Water & Wastewater directly to schedule these tests. This applies to both existing hydrants as well as those proposed for the site. 32

Paj 33

Item 4. NeighborGood Division Street Office at 223 West Division Street File #: S-23-03 February 1, 2023 Page 4 of 4 4. Water impact fees may be required to be paid prior to Certificate of Occupancy for this project. WASTEWATER 1. The City of Dover sanitary sewer system is available to this site. The developer is responsible for all costs associated with extending and providing service and capacity to the proposed development. 2. Prior to plan approval, it may be required to submit the sanitary sewer system plans to the DNREC, Division of Water Resources, Surface Water Discharges Section for review and approval. The owner/developer is responsible for providing all application fees, completed forms and plan sets directly to DNREC. 3. Wastewater impact fees may be required to be paid prior to Certificate of Occupancy for this project. GENERAL 1. The applicant is advised that depending upon the size of the existing water service and sanitary sewer lateral to be abandoned, flowable fill may be required. 2. Construction plans will not be reviewed by our office unless all previous comments have been clearly addressed within the plan set and accordingly identified within an itemized response letter and with the Water/Wastewater Initial Plan Submission Checklist, which can be obtained from the following website: https://imageserv9.team- logic.com/mediaLibrary/198/WaterWastewaterHandbookFinal_1.pdf, page 88. SANITATION / STORMWATER / STREETS 1. None I F Y OU H AVE A NY Q UESTIONS OR N EED TO D ISCUSS ANY OF THE A BOVE C OMMENTS , P LEASE C ALL THE A BOVE C ONTACT P ERSON AND THE P LANNING D EPARTMENT AS S OON AS P OSSIBLE . 33

Paj 34

Item 4. CITY OF DOVER ELECTRIC DEVELOPMENT ADVISORY COMMITTEE APPLICATION REVIEW COMMENTARY STAFF D.A.C. MEETING DATE: FEB 1, 2023 APPLICATION: NeighborGood Partners Division Street Office at 223 West Division Street FILE #: S-23-03 REVIEWING AGENCY: City of Dover Electric Department CONTACT PERSON: Shawn Burgett, Engineering Services & System Ops Superintendent CONTACT PHONE #: 302-674-7568 CONTACT EMAIL #: sburgett@dover.de.us T HE S UBJECT P ROPOSAL HAS BEEN R EVIEWED FOR C ODE C OMPLIANCE , P LAN C ONFORMITY AND C OMPLETENESS IN A CCORDANCE WITH THIS A GENCY ’ S A UTHORITY AND A REA OF E XPERTISE . T HE F OLLOWING I TEMS HAVE BEEN I DENTIFIED AS E LEMENTS W HICH N EED TO BE A DDRESSED BY THE A PPLICANT : CITY AND STATE CODE REQUIREMENTS ELECTRIC 1. The roadway and curbing must be in. 2. The right-of-way must be within 6" of final grade. 3. The property corners must be staked. 4. Owner is responsible for locating all existing underground electric, communications and water facilities. 5. Owner is responsible for installing all conduits and equipment pads per the City of Dover Engineering Department specifications. 6. Owner is responsible for site and/or street lighting. 7. Meter locations will be determined by City of Dover Engineering Department. 8. Load sheets and AutoCAD compatible DXF or DWG diskettes of site plans, including driveways, are required prior to receiving approved electrical construction drawings. 9. Any relocation of existing electrical equipment will be engineered by the City of Dover Electric Department. Developer may be required to perform a quantity of the relocation. Any work performed by the City of Dover will be at the owner’s expense. 10. Prior to construction, owner is responsible for granting an easement to the City of Dover Electric Department. Easement forms will be furnished and prepared by the City of Dover Electric Engineering Department. 11. Fees will be assessed upon final site plans. The owner will be responsible for fees assessed prior to construction. Owner is required to sign off plans prepared by the Electric Department. 12. Must maintain 10' clearance around all electrical equipment, unless pre-approved by the City of Dover Electric Engineering Department. 34

Paj 35

Item 4. NeighborGood Partners Division Street Office at 223 West Division Street File #: S-23-03 Feb 1, 2023 Page 2 of 2 13. Prior to the completion of any/all designs and estimates, the owner is responsible for providing the Electric Engineering Department with a physical address of the property. 14. All Engineering and design for Dover Electric will be engineered upon final approved plans. All Engineering work will be furnished by the City’s Electric Engineering Department. RECOMMENDATIONS SUGGESTED AS CONDITIONS OF APPROVAL TO MEET CODE OBJECTIVES ELECTRIC 1. Owner must give the City of Dover Electric Department three (3) months’ notice prior to construction. Owner is responsible for following the requirements outlined in the City of Dover’s Electric Service Handbook. The handbook is now available on the website at the following link: https://evogov.s3.amazonaws.com/media/27/media/13108.pdf. ADVISORY COMMENTS TO THE APPLICANT ELECTRIC 1. Provide load sheets as soon as possible for proper sizing of transformers and creation of primary fee estimates. Current load sheets can be found at the following link: https://www.cityofdover.com/media/Electric%20Department/COD%20Electric%20Load%20Sheet.pdf. I F Y OU H AVE A NY Q UESTIONS OR N EED TO D ISCUSS ANY OF THE A BOVE C OMMENTS , P LEASE C ALL THE A BOVE C ONTACT P ERSON AND THE P LANNING D EPARTMENT AS S OON AS P OSSIBLE . 35

Paj 36

C F S-23-03 Item 4. I I T R CITY OF DOVER Y E DEVELOPMENT ADVISORY COMMITTEE O M F A APPLICATION REVIEW COMMENTARY R D.A.C. MEETING DATE: 02/01/23 D S O H V A E L R APPLICATION: NeighborGood Partners Division Street Office at 223 W Division St FILE #: S-23-03 REVIEWING AGENCY: City of Dover, Office of the Fire Marshal CONTACT PERSON: Jason Osika, Fire Marshal PHONE #: (302) 736-4457 THE SUBJECT PROPOSAL HAS BEEN REVIEWED FOR CODE COMPLIANCE, PLAN CONFORMITY, AND COMPLETENESS IN ACCORDANCE WITH THIS AGENCY’S AUTHORITY AND AREA OF EXPERTISE. THE FOLLOWING ITEMS HAVE BEEN IDENTIFIED AS ELEMENTS WHICH NEED TO BE ADDRESS BY THE APPLICANT: CITY AND STATE CODE REQUIREMENTS: 1. Proposed occupancy classification is business. 2. Building Access shall be no further than 50 feet from a primary entrance Where buildings are provided with an automatic sprinkler system installed in accordance with NFPA 13, access shall be no further than 100 feet from the primary entrance. (2021 Delaware State Fire Prevention Regulations, 705, Chapter 5, 3.4) 3. Parking shall be prohibited in front of the primary entrance for a width of not less than 1.5 times the width of the door(s) or for 10 feet, whichever is greater. (2021 Delaware State Fire Prevention Regulations, 705, Chapter 5, 6.3.2) 4. Perimeter access shall be 30% (15% if sprinklered) and clearly shown on the plans. Perimeter Access minimum width shall be10 feet for one-story buildings and 15 feet for buildings of two or more stories, measured from the face of the building at grade with a maximum slope of ten percent (10%). Plantings and utility services (includes condenser units, transformers, etc.) shall be permitted within the perimeter access, and shall not interfere with emergency services fire ground operations. If a physical barrier (fence, pond, steep slope, etc) prevents access, that portion of the building perimeter shall not be included in the calculation of Percent of Perimeter Access. (2021 Delaware State Fire Prevention Regulations, 705, Chapter 5, 3.5) Where parking is located between the building and perimeter access area, parking shall not be located closer than 10 feet to the exterior wall for one-story buildings and 15 feet to the exterior wall for building of two or more stories. 36

Paj 37

Item 4. 5. NFPA 72 compliant Fire Alarm System TBD (If occupant load of second floor is 50 or greater) per occupancy code requirements. Fire alarm in place of assembly. Fire alarm required. Any new occupancy or new portion of an occupancy determined to be a place of assembly by the fire marshal and is capable of receiving an occupant load of 75 persons or greater, shall be required to install a fire alarm in accordance with NFPA codes governing the installation of fire alarms and the National Electrical Code. Fire alarm system required. Any existing occupancy or portion of an existing occupancy determined to be a place of assembly by the fire marshal, and is undergoing renovations in excess of 50 percent of the assessed value of the building and is capable of receiving an occupant load 75 persons or greater or is being enlarged to receive an occupant load of 75 persons or greater, shall be required to install a complete fire alarm system in accordance with NFPA codes governing the installation of fire alarms and the National Electrical Code. Public mode audible requirements. To ensure that audible public mode signals are clearly heard by occupants of a structure, they shall have a sound level at least 15 decibels (dB) above the average ambient sound level or five decibels (dB) above the maximum sound level having a duration of at least 60 seconds, whichever is greater, measured five feet (1.5m) above the floor in the area required to be served by the system using the A-weighted scale dBA. In the event the stated requirement cannot be met a shunt trip relay/switches shall be the approved method of meeting the intent of this section of the Code. (City Code of Ordinances 46-171) 6. The installation of natural gas and LP gas meters, regulators, valves, and LP gas bottles shall be protected from impact damage by impact protection. Natural gas and LP gas meters, regulators, and valves located inside structures shall have impact protection, except when located in separate protected utility rooms. Dimensions of bollards. Bollards shall be a minimum of six-inch diameter filled with concrete. The bollard shall be set into the ground at a depth of at least 36 inches (three ft.) embedded in concrete at a minimum of 18 inches surrounding the bollard. The bollards must be a least 48 inches (four ft.) in height above the finish grade elevation. Any deviation of the stated requirements must be approved by the fire marshal and/or chief building inspector. The above dimensions shall serve as the requirement for installation; however, the fire marshal and/or chief building inspector shall have the authority to require more stringent dimensions to fit the needs of devices warranting impact protection. Color of bollards. Bollards should be of the following colors; yellow, amber or orange. All colors shall be of fluorescent or have a reflective coating. Any deviation of the stated requirements must be approved by the fire marshal and/chief building inspector. (City of Dover Code of Ordinances, 46-4) 7. Every house, building or structure used or intended for use as living quarters or as a place for conducting business, and having any wall facing or abutting any public or private street or alley, shall have displayed on that wall, in legible, easily read characters which are of contrasting color to the background, the proper street number for such house, building, or structure in accordance with the following: 37

Paj 38

Item 4. One-family and two-family residential structures, height, the number shall measure a minimum of four inches in height, location, the number shall be placed on the house above or to the left or right of the front entrance, color, the number shall be contrasting to the background color, Arabic numerals, all numbers shall be Arabic numerals. Multiple-family dwellings, measurements, the number shall measure a minimum of six inches when identifying individual apartments with exterior doors, and 12 inches when identifying buildings with apartment complexes where there are two or more buildings not assigned street addresses. Individual buildings with street addresses shall have numbers measuring six inches, location, numbers shall be placed either in the center of the building or on the street end of the building so as to be visible from either the public or private street or from the parking lot, color, numbers shall be contrasting to the background color, Arabic numerals, all numbers used shall be Arabic numerals. Commercial, industrial and office buildings, height, the numbers shall measure a minimum of 12 inches in height, location generally, numbers shall be placed either in the center of the building or on the street end of the building so as to be visible from either the public or private street or from the parking lot, property line or driveway, should the building be located far enough from a public or private road so that the numbers are not clearly visible from the street, then the street address shall also be posted on the property at or near the property line or driveway to said building, color; each building, numbers shall be contrasting to the background color and shall be placed on each building in the complex, Arabic numerals, all numbers used shall be Arabic numerals, Shopping centers. Shopping centers consisting of two or more stores shall have a tenant or suite number affixed to the front of the tenant space and on the outside of the rear door which corresponds with that tenant space. Numbers shall measure six inches in height. (City of Dover Code of Ordinances, 98-344) 8. A lock box (Knox) containing any and all means necessary for fire department access shall be provided at the following occupancies: any occupancy that contains a fire alarm signaling system that is monitored off-site, or any occupancy that contains an automatic sprinkler system. (2021 Delaware State Fire Prevention Regulations 705, Chapter 5, 2.4) Secured key systems. When required; exemption. A secured key system shall be required for any new or existing building where a fire alarm or sprinkler system is being installed. It shall be the responsibility of the owner or occupant to keep a set of keys in the secured key box that are current to the locks of the protected occupancy. Buildings with 24-hour staffing or guard service shall be exempt from this subsection. Location. The secured key system shall be located as close to the main entrance as possible. Should the building design not allow the secured key system to be located by the main entrance, the fire marshal and fire chief shall come to an agreement as to an alternate location for the key box. A secured key system, once installed, shall not be obstructed from view or obstructed by any means that would delay the fire department access to the box. 38

Paj 39

Item 4. Required keys. Keys to be secured in the key box shall include keys to all points of ingress or egress, whether on the interior or exterior of the building, and keys to locked mechanical rooms, electrical rooms, elevator rooms, fire alarm and sprinkler controls and any area protected by automatic fire detection. Keys to individual residential apartment units are not required. Ordering responsibility. It shall be the responsibility of the general contractor to order the key box for new buildings. It shall be the responsibility of the owner or tenant to order the key box for existing buildings. Installation before testing. No acceptance test for sprinklers or fire alarms shall be conducted before the installation of a key box. (City Code of Ordinances 46-127) Knox Box to be mounted 6 feet above ground level 9. All required means of egress shall have an exit discharge consisting of a non-slip surface and leading to and terminating at a public way. NFPA 101 10. Project to be completed per approved Site Plan. 11. Full building and fire plan review is required. 12. Separate building permits/plans submission will be required for each building and/or tenant fit out. If the permit submission is for a “shell” a Certificate of Occupancy will not be issued. Separate plans and permits submissions will be required for each “tenant fit out” at which time a Certificate of Occupancy will be issued upon compliance/completion of each “tenant fit out”. Each “shell” will require a fire permit for sprinkler and fire alarm if applicable. Those systems (for the “shell”) must be accepted into service prior to any “tenant fit out” fire permits being issued. 13. Construction or renovations cannot be started until building plans are approved. 14. Fire alarm systems, fire suppression systems, hoods, exhaust ducts, and hood suppression systems require a fire permit from the Fire Marshal’s Office. This work cannot be started until the permit is approved. 15. Building cannot be occupied by the public until a Certificate of Occupancy is obtained. 16. The following is City Ordinance, Appendix B-Zoning, Article 8 Enforcement and Penalties: Section 1. - Building permits. No building or structure in any district shall be erected or structurally altered without a building permit duly issued upon application to the building inspector. No building permit shall be issued unless the proposed construction or use is in full conformity with all the provisions of this ordinance. Any building permit issued in violation of the provisions of this ordinance shall be null and void and of no effect, without the necessity for any proceedings for revocations or nullification thereof, and any work undertaken or use established pursuant to any such permit shall be unlawful (see section 4 for penalties). 39

Paj 40

Item 4. 1.1 No building permit shall be issued for the construction or alteration of any building upon a lot without frontage upon, or legal permanent access to, a public street improved to the satisfaction of the planning commission, or without access to a public sewer. 1.2 No building permit shall be issued for any building where the site development plan of such building is subject to approval by the planning commission, except upon approval of such plans approved by the said commission. 1.21 No building permit shall be issued for any building in a subdivision unless the subdivision plot has been approved by the planning commission. 1.3 No building permit shall be issued for a building to be used for any conditional use in any zone where such use is allowed only with approval of the planning commission, unless and until such approval has been duly granted by the said commission. (Ord. of 7-12-1993, § 3) ADDITIONAL / SPECIFIC REQUIREMENTS TO OBTAIN APPROVAL: 1. Ensure proper spacing between the two buildings per the building and fire code APPLICABLE CODES LISTED BELOW (NOT LIMITED TO): 2021 NFPA 1 Fire Code (NFPA; National Fire Protection Association) 2021 NFPA 101 Life Safety Code (NFPA; National Fire Protection Association) 2019 NFPA 72 National Fire Alarm and Signaling Code (NFPA; National Fire Protection Association) 2019 NFPA 13 Installation of Sprinkler Systems (NFPA; National Fire Protection Association) 2009 IBC (International Building Code) Latest editions of all other NFPA Codes as defined by the Delaware State Fire Prevention Regulations 2021 Delaware State Fire Prevention Regulations City of Dover Code of Ordinances *If you have any questions or need to discuss any of the above comments, please call the above contact person listed. 40

Paj 41

Item 4. CITY OF DOVER D E DEVELOPMENT ADVISORY COMMITTEE L APPLICATION REVIEW COMMENTARY D O T =============================================================== APPLICATION: NeighborhoodGood Partners at 223 W Division Street FILE#: S-23-01 REVIEWING AGENCY: DelDOT CONTACT PERSON: Joshua Johnson PHONE#: 302-760-2141 =============================================================== THE SUBJECT PROPOSAL HAS BEEN REVIEWED FOR CODE COMPLIANCE, PLAN CONFORMITY AND COMPLETENESS IN ACCORDANCE WITH THIS AGENCY'S AUTHORITY AND AREA OF EXPERTISE. THE FOLLOWING ITEMS HAVE BEEN IDENTIFIED AS ELEMENTS WHICH NEED TO BE ADDRESSED BY THE APPLICANT: CITY & STATE CODE REQUIREMENTS: No person, firm, corporation or the like shall construct, open, reconstruct, maintain, modify or use any crossing or entrance onto a state-maintained highway, street or road, including any drainage modifications leading into or carried by the highway drainage system, without first having complied with standards and regulations adopted by the Department and having obtained a permit issued by the Department. Please contact the Delaware Department of Transportation - Development Coordination section to begin permit process. RECOMMENDATIONS SUGGESTED AS CONDITIONS OF APPROVAL TO MEET CODE OBJECTIVES: ADVISORY COMMENTS TO THE APPLICANT: 1. DelDOT issued Record and Entrance Plan approvals for this project in April 2022 which are valid for 3 years. If there are any changes to the proposed use, submit to DelDOT for a new Letter of No Objection to Recordation (LONOR). 41

Paj 42

KENT CONSERVATION DISTRICT Item 4. 1679 SOUTH DUPONT HIGHWAY • DOVER, DELAWARE 19901• (302) 608-5370 • WWW.KENTCD.ORG CITY OF DOVER DEVELOPMENT ADVISORY COMMITTEE APPLICATION REVIEW COMMENTARY FEBRUARY 2023 APPLICATION: NeighborGood Partners Division Street Office at 223 W Division St FILE #: S-23-03 REVIEWING AGENCY: Kent Conservation District CONTACT PERSON: Kate Owens PHONE: (302) 608 – 5370 EMAIL: stormwater@kentcd.org THE SUBJECT PROPOSAL HAS BEEN REVIEWED FOR CODE COMPLIANCE, PLAN CONFORMITY AND COMPLETENESS IN ACCORDANCE WITH THIS AGENCY’S AUTHORITY AND AREA OF EXPERTISE. THE FOLLOWING ITEMS HAVE BEEN IDENTIFIED AS ELEMENTS WHICH NEED TO BE ADDRESSED BY THE APPLICANT: Source: 2019 Delaware Sediment and Stormwater Regulations CITY AND STATE CODE REQUIREMENTS: 1. As the disturbance for this site exceeds 5,000 square feet but is less than 1 acre, a standard erosion and sediment control plan must be reviewed and approved by the District prior to any land disturbing activity (i.e. clearing, grubbing, filling, grading, etc.) taking place. 2. Please provide Kent Conservation District with the following: a. A completed and signed Standard Plan Application for Non-Residential Construction. b. Standard plan application fee. c. Two (2) hard copies of the plan set that is signed/sealed by the design engineer and has the Sediment & Stormwater Owners Certification signed by the owner. d. One (1) electronic PDF of the construction plan set that contains the erosion and sediment control plan that is signed/sealed by the design engineer and has the Sediment & Stormwater Owners Certification signed by the owner. ADVISORY COMMENTS TO THE APPLICANT: 1. A letter of no objection to construction will be provided upon approval of the Standard Plan Application for Non-Residential Construction. 42

Paj 43

Item 4. January 6, 2023 Ms. Mary Ellen Gray City of Dover Planning & Inspections P.O. Box 475 Dover, DE 19903 RE: Request for Elimination of Curbing Requirements (Article 6, Section 3.6 (b)) NeighborGood Partners – Division Street Office 223 & 225 W. Division Street Dear Ms. Gray: We are requesting relief from the requirements of Article 6, Section 3.6 (b) pertaining to the enclosure of all permanent parking areas with upright curbing due to the needs of stormwater conveyance. In this instance only a portion of the proposed parallel parking spaces can be enclosed with raised curbing and still allow stormwater drainage conveyance to discharge properly. Bollards will be installed in an appropriate location, at the head of the easternmost parking space alongside the alley at the rear of the proposed building. The bollards will prevent damage to surrounding infrastructure and property. For these reasons, we are hereby requesting a waiver from the installation of curbing in the proposed parking area. Please feel free to call with any questions. I can be reached directly at 302-744-9875 or by email at kburchard@mountainconsulting.com. Thank you for your consideration. Sincerely, MOUNTAIN CONSULTING, INC. Kyle Burchard, P.E. Director of Engineering 103 South Bradford Street, Dover, DE 19904 • Phone: 302-744-9875 • Fax: 866-672-6428 43 www.mountainconsultinginc.net

Paj 44

Item 4. 44

Paj 45

Item 4. 45

Paj 46

Item 4. C-6 C-10 C-3 C-10 TWO (2) TRASH BINS AND ONE (1) RECYCLING BIN TO BE STORED HkB HSG-B C-9 C-12 C-12 C-11 C-13 C-1 C-7 C-2 C-8 C-4 C-5 PROPOSED CONSTRUCTION NOTES C-1 C-8 C-2 C-3 C-9 C-4 C-10 P.O. BOX 558 DOVER, DE 19903 T-302-744-9875 NEIGHBORGOOD PARTNERS - DIVISION STREET OFFICE C-11 F-866-672-6428 C-5 C-12 C-6 C-7 C-13 46 P:\_PROJECTS\_2019 PROJECTS\Engineering Projects\2019020EM_NCall Dover Office Building\CADD\2023 SITE PLAN.dwg, SITE PLAN, 1/6/2023 11:39:20 AM

Paj 47

Item 4. 47

Paj 48

Item 5. City of Dover DATA SHEET FOR SITE DEVELOPMENT PLAN REVIEW DEVELOPMENT ADVISORY COMMITTEE MEETING OF February 8, 2023 PLANNING COMMISSION MEETING OF February 21, 2023 Plan Title: Leander Lakes III Apartments, S-23-04 Plan Type: Site Development Plan and Minor Subdivision Plan Active Recreation Area Plan Location: South side of Forrest Avenue west of Dover High Drive Address: Unaddressed off Forrest Avenue (Part of property at 2285 Forrest Avenue) Tax Parcel: ED-05-075.00-01-06.00-000 Owner: Calvary Baptist Church of Dover Equitable Owner/Developer: Leander Lakes III, LLC. Site Area: Lot 1: 50.19 acres +/- (Residual) Lot 2: 25.00 acres +/- (Project Area) Zoning: RM-2 (Medium Density Residence Zone and partially subject to COZ-1 (Commercial Overlay Zone) Current Use: Vacant Land (Agricultural and Woodland) with proposed for new Place of Assembly (Church) construction in Lot 1 Area Proposed Use: Garden Style Apartments (Multi-family Community) Dwelling Units: 200 units Parking: Required: 450 spaces Proposed: 450 spaces Water and Sewer: City of Dover For Consideration: Active Recreation Area Plan Recreation Area: Required – 55,000 SF (1.26 +/- acres) Provided – 1.61 +/- acres Waiver Requests: None P. O. Box 475 Dover, DE 19903 48 Community Excellence Through Quality Service

Paj 49

Item 5. S-23-04 Leander Lakes III Apartments Site Plan DAC Report of February 8, 2023 Page 2 of 11 CITY OF DOVER DEVELOPMENT ADVISORY COMMITTEE APPLICATION REVIEW COMMENTARY D.A.C. MEETING DATE: February 8, 2023 APPLICATION: Leander Lakes III Apartments FILE #: S-23-04 REVIEWING AGENCY: City of Dover Planning CONTACT PERSON: Katherine Oehmke, Planner I and Dawn Melson-Williams, Principal Planner PHONE #: (302) 736-7196 I. PLAN SUMMARY: This application is for Review of a Site Development Plan Application for the construction of eight (8) 3-story garden style 24-unit apartment buildings and 1 (one) 2-story 8 unit building for a total of two hundred (200) units. Also proposed are 450 parking spaces, walking paths, landscaping, recreation areas and other site improvements. The project area of 25 acres is zoned RM-2 (Medium Density Residence Zone) and partially subject to the COZ-1 (Corridor Overlay Zone) with the balance of the overall property zoned R-10 (One Family Residence Zone and partially subject to COZ-1 (Commercial Overlay Zone). The application includes a Minor Subdivision Plan to create Lot 1 of 50.19 acres+/- (residual) and Lot 2 of 25 acres (project area). The property is located on the south side of Forrest Ave west of Dover High Drive. The owner of record is Calvary Baptist Church of Dover and equitable owner/developer is Leander Lakes III, LLC. Property is currently unaddressed on Forrest Ave. Tax Parcel: ED-05-075.00-01-06.00- 000. Council District 1. For Consideration: Active Recreation Area Plan. Existing Property: With the overall 75.51-acre property, the property has frontage on Forrest Avenue (Route 8) and Artis Drive, but the main site access is from Forest Avenue. The property is crossed by a small stream and includes woodlands, wetlands, and agricultural lands. In the northeast corner of the site, a place of worship (church) building has been approved under Conditional Use Site Plan C-19-06. The proposed church building sits back over 625 feet from Forrest Avenue with a large stormwater management area directly adjacent to the road. The church building location is flanked by parking areas on the east side of the building and a large open space in front of the proposed building reserved for a future building expansion. There are large expanses of open land on the tract to the southern and western portions of the property. The southeastern portion of the property consisting of 25 acres is the location of this proposed Apartment Complex. Previous Applications: The property was annexed into the City in early 2007 along with several other properties on the west side of the City following the annexation of the Carey Farm for the site of the new Dover High School (AX-06-09). At the time of annexation, the property was zoned to R-10 (One 49

Paj 50

Item 5. S-23-04 Leander Lakes III Apartments Site Plan DAC Report of February 8, 2023 Page 3 of 11 Family Residence Zone) and COZ-1 (Corridor Overlay Zone). Prior to annexation into the City of Dover, the Calvary Baptist Church completed a Site Plan review process under the jurisdiction of Kent County (CS-03-08). That Plan was then accepted by the City through Administrative Site Plan review (MI-07-07). A Building Permit (#07-547) for construction of the church building was issued but not acted upon and then expired. The overall 75-acre property is subject of Conditional Use Site Plan Application C-19-06 Calvary Baptist Church for construction of a new place of worship and associated site improvements including a site entrance from Forrest Avenue. The Conditional Use Site Plan received conditional approval by the Planning Commission at their July 15, 2019 meeting, an extension of plan approval on May 17, 2021, and Final Plan Approval in December 2021. Preparations for the start of construction are occurring as the Building Permit is pending review. The property was the subject of Rezoning Application Z-22-02 focusing on a 25 acre portion of the parcel. In October 2022, the zoning for the 25 acres was approved as RM-2 (Medium Density Residence Zone) and partially subject to the COZ-1 (Corridor Overlay Zone). Surrounding Land Uses The surrounding parcels are zoned residential. Located to the north across Forrest Avenue (Route 8) are a series of lots with single family homes which are outside City limits and under the jurisdiction of Kent County. To the east is the Destiny Christian Church which has access to Forrest Avenue. A second church, Dover Christian Church, also fronts on Forrest Avenue but has access from Dover High Drive. Adjoining the subject site to the southeast, there is multi- family development for 240 apartment units known as Leander Lakes (S-12-18). To the south is agricultural land outside of City limits and to the west of the project area is a wooded portion of the main parcel. Preliminary Land Use Services Review (PLUS) An application (PLUS Review #2022-11-06) related to this Leander Lakes III project was reviewed by the State’s Preliminary Land Use Services, as required by the City of Dover’s Memorandum of Understanding (MOU). It was reviewed by the state at the meeting on November 16, 2022. This MOU requires that non-residential developments of over 75,000 square feet or residential developments containing 125 or more dwelling units complete the PLUS Review process prior to application submission. The development proposal submitted by the developers to PLUS envisioned 200 apartment units for the 25-acre portion of the unaddressed parcel of Forrest Avenue. Copies of the PLUS Review Comments are provided. The Applicant’s Response to PLUS must be submitted. II. PROJECT DESCRIPTION: The Site Development Plan as submitted by the applicant for the Leander Lakes III Apartments consists of nine (9) garden style apartment buildings with active recreation areas and walking paths. This information is provided to show how the Site Plan submitted is achieving the aims set out in the Zoning Ordinance, Article 5 Section 10: Open space, recreation, and other public facilities. The estimated minimum and proposed area of recreation initially submitted was 55,000 SF. After proposed revisions to the Recreation Plan, the area is estimated at 1.61 Acres +/-. 50

Paj 51

Item 5. S-23-04 Leander Lakes III Apartments Site Plan DAC Report of February 8, 2023 Page 4 of 11 Minor Subdivision Plan This Site Plan is also asking for a minor subdivision of the 75 +/- acres main parcel to create the project site of 25 acres with frontage on Forrest Avenue. The project area parcel (Lot 2) is to coincide with the land area recently rezoned to the RM-2 zoning district. Lot 1 of 50.19 acres is the residual area of the main parcel (proposed church location). III. ZONING REVIEW: This property is unaddressed and was recently rezoned as RM-2 (Medium Density Residential Zone) with a portion fronting on Forrest Avenue being subject to COZ-1 (Commercial Overlay Zone). The RM-2 zone allows for a variety of housing unit types ranging from single family detached dwellings, duplexes, multiplexes, and townhouses to garden apartments. The RM-2 zone has a maximum gross residential density limitation of eight dwelling units per acre. COZ-1 (Corridor Overlay Zone) The subject site involved with this application is partially located within the COZ-1 (Corridor Overlay Zone). The COZ-1 impacts only the front 520 feet of the property along Forrest Avenue. The proposed apartment complex (main area with buildings) is not within the COZ-1; only a portion of the entrance drive of Toulson Terrace is within the COZ-1. Thus, this means that only portions of the site and its development are subject to the COZ-1 provisions. The Zoning Ordinance details the requirements of the COZ-1 in Article 3 §26 and its subsections. The Corridor Overlay Zone as a planning and growth management tool is designed to foster and attractive, efficient, and economically vibrant urban corridor along Route 8/Forrest Avenue and Saulsbury/McKee Roads. To this end, more stringent standards are applied to development taking place along the corridor. A discussion of the provisions of the COZ-1 which apply to this application follows below. The plan as presented is in compliance with the requirements listed below. Since no buildings are in the COZ-1 area, they are not required to meet the COZ-1 provisions. • Achieves the following for the parking lot layout/arrangement: parking lot location is not in the front yard setback and the number of parking spaces versus islands. Since there is currently no building within the COZ-1 zone area, the parking lot is accepted in its current location. • The proposal meets the requirement that 25% of the lot consist of landscaped open space. A significant amount of development area (Lot 2) remains as open space. • Street frontage of Forrest Avenue is required to have a landscaped open space of 25 feet and provide one tree per 50 (fifty) feet of frontage. (See Landscape discussion.) • Non-frontages (side and rear yards) in the COZ-1 area are required to have landscaped open space of 15 feet when adjacent to residential uses and landscaped open space of 5 feet when adjacent to non-residential uses and to provide one tree per 75 (seventy-five) feet. (See Landscape discussion.) IV. PARKING SUMMARY: The parking requirement for apartments is based on a rate of two (2) parking spaces per dwelling unit plus 0.25 space per dwelling unit for visitor parking. Based on the number of dwelling units (200 units), this site would require 450 parking spaces. The plans submitted identify a total of 51

Paj 52

Item 5. S-23-04 Leander Lakes III Apartments Site Plan DAC Report of February 8, 2023 Page 5 of 11 450 parking spaces located around the perimeter of the complex and including handicapped accessible parking spaces near each building. Bicycle Parking The site plans submitted identify three (3) bike rack locations, but no details are provided. Bicycle parking is required at a ratio of one space for every twenty parking spaces. If the site is required to have 450 vehicle parking spaces, then twenty-three (23) bicycle parking spaces are required. Upright Curbing The upright cubing for parking lots and drive isles is required by the requirements of the Article 6 Section 3.6(b) of the Zoning Ordinance. Locations and type of curbing must be clarified on the Site Plan. V. SITE CONSIDERATIONS: Access The access to this Apartment Complex portion of the site is off the future development for the Calvary Baptist Church which has an entrance/exit from Forrest Avenue. The connecting entrance drive for the Apartment Complex is labeled as Toulson Terrace. The on-site circulation of the proposed Leander Lakes III apartment complex also connects to the parking lot drive aisle (Isabelle Isle) of the existing Leander Lakes apartments. Rear Emergency Access Rear Emergency Access is required for some residential dwelling types. According to Article 5, Section 17 of the Zoning Ordinance an 18 ft. wide Secondary Fire Lane or 18 ft. wide subgrade emergency access lane is required for Apartments that are 2-3 stories to serve as rear access. This is to provide access to rear building areas. The plan calls for an emergency access lane network along the inside of the common area with a 10 foot wide concrete path with an additional 4 foot of grass pavers on either side. This creates a lane of 18 foot width to provide a fire access to the back side of each of the buildings. The Fire Marshal’s Office will also evaluate these fire protection measures as related to the fire lane requirements of the applicable Fire Codes. Lighting Staff counted twelve (12) light poles on the Site Plan between the buildings and the parking lots. No further details are listed. Open space lighting for the walking paths or the emergency access lane paths was shown on the Revised Recreation Area Exhibit Plan. Sidewalks Sidewalks are shown on the plans between the parking lots and the building access points. The revisions on the Recreation Area Exhibit Plan now shows select sidewalks/pathways depicted as connecting directly to the recreational amenity areas. There are sidewalks that continue from Building A and Building I in Leander Lakes III across Toulson Terrace to connect to the neighboring community of Leander Lakes Apartments. Dumpsters The Dumpster requirement for apartments is two Dumpsters for the first 48 units and one Dumpster for each additional 24 units or fraction thereof. Based on 200 apartment units, a total 52

Paj 53

Item 5. S-23-04 Leander Lakes III Apartments Site Plan DAC Report of February 8, 2023 Page 6 of 11 of nine (9) Dumpsters are required. There is a single dumpster space for each building drawn on the site plans at the back end of the parking lot. There must be space for both trash and recycling containers in these Dumpsters. Wetlands & Buffering The Zoning Ordinance, Article 5 §11.22 prescribes provisions related to wetland areas. It requires setbacks from wetland areas that are over 0.25 acres in size. This plan depicts Non-Tidal wetlands which coincide with a stream that crosses the property. A 100-foot setback is required; however, this can be reduced to 50 feet with implementation of a Riparian Buffer or reduced to 30 feet with bank stabilization. Adjacent to the wetland/stream the plan shows a 50 foot riparian buffer where existing vegetation will be maintained. The site parking lot circulation drive aisle (Porter Place) crosses the stream in two locations. More detail on the culvert and design of the road crossings is needed and will require specific permits. VI. BUILDING ARCHITECTURE: The applicant has submitted floor plans for the 24-unit apartment buildings, as well as elevations for both the three story 24-unit buildings and the two story 8-unit building. The floor plans outline 2-bedroom units, 2-bedroom + den units, and 3-bedroom units. Each unit has a balcony or patio area. The larger buildings have two points of entry as an open stairwell corridor to access the four units on each floor. The detail drawings show the front, rear, left and right building elevations. Additionally detailed drawings for the 24-unit buildings were provided showing the side gable, corner tower, entry, projecting balcony, and rear gable group. Each of the gables has a decorative gable trimwork. The exterior finishes of the apartment buildings consist of a brick watertable, 6-inch horizontal vinyl siding with select areas of vertical siding (colors to be chosen by the owner, 12-inch metal wrapped trim board, and 8-inch fascia boards. The siding on the select gable elements is vertical with 3-inch trim bands around the ends. Architectural asphalt shingles are shown for the pitched roofs. VII. TREE PLANTING AND LANDSCAPE PLAN: Zoning Ordinance, Article 5 Section 16 lays out the requirements for tree planting and preservation. A new project is required to provide tree planting at a rate of one (1) tree per 3,000 SF of “Development Area.” The Cover Sheet (Sheet C-101) of the Plans submitted appear to note existing woodland on-site providing an area of 2.01 acres for this feature generally found in the southwest corner of the project area. The Zoning Ordinance Article 5, Section 16 defines “Woodland” as follows: Woodland. An area of contiguous wooded vegetation (7,500 square feet or greater), where trees exist at a density of at least one tree with a caliper dimension of six inches or greater per 375 square feet of land and where the tree branches form a contiguous canopy. According to plans, there are 2.01 acres of existing woods, and they propose to remove 0.45 acres of these woods to make way for the building site. Based on the number of acres for this development site, the minimum required number of trees is 341. The site plans show 367 trees spread over the site around the parking lot and in the internal open space areas. There are tree plantings adjacent to Forrest Avenue and along the property lines in the COZ-1 area of the parcel. However, there are no trees proposed on the plan along the balance of 53

Paj 54

Item 5. S-23-04 Leander Lakes III Apartments Site Plan DAC Report of February 8, 2023 Page 7 of 11 the entrance drive labeled Toulson Terrace leading to the apartment complex. The plan calls for three types of deciduous and evergreen trees but does not specify tree species. COZ-1 Landscaping Requirements The COZ-1 requires that a minimum of 25% of the site be landscaped open space. For this site approximately 59.4% of the entire parcel is open space (40.6% is impervious cover per the submitted plan). By estimation the area of the site in the COZ-1 area also complies with this open space requirement as only the entrance drive cross though that area. The COZ also requires at least one tree per 50 linear feet of frontage be planted; three trees are planted along the multi- modal path at the Forrest Avenue frontage. One tree per 75 feet is also required on non-frontage perimeters within the COZ-1 zone. There are trees on the west and east property lines of the project area in the COZ-1. VIII. ACTIVE RECREATION AREA Active Recreation Area Plan Review The Zoning Ordinance, Article 5 Section 10 sets out requirements to preserve areas of open space within residential developments which are designed to provide buffer spaces between developing areas, to preserve existing natural and historic features and to establish a network of open spaces within the built environment to provide a balance between developed and undeveloped lands, wildlife habitat conservation, the preservation of scenic view corridors, and to provide residents opportunities to engage in passive recreational activities. Zoning Ordinance, Article 5 Section 10.11 notes the purpose of providing Recreation Areas. Article 5 §10.1 Recreation areas. 10.11 Purpose. The purpose of this section is to ensure that active recreation areas are provided as an integral design element within residential developments and that such facilities are of an adequate scale in relation to the size of the residential development and which provide residents with a variety of active recreational pursuits. The applicant has submitted a Revised Recreation Areas Exhibit Plan dated February 8, 2023. This Revised Plan makes some changes to the amenities as one of the previous playground areas is now Fitness Area. An itemized listing of the Recreation Areas and materials is given on the Plan sheet. See Recreation Plan Review Report for more detailed review (attached document) including an Addendum on the Revised submission. IX. CITY AND STATE CODE REQUIREMENTS: The subject proposal has been reviewed for Code compliance, plan conformity, and completeness in accordance with this agency’s authority and area of expertise. The following items have been identified as elements which need to be addressed by the applicant: 1) Active Recreation Area: The applicant is responsible for providing an Active Recreation Area of a minimum 55,000 SF. The Plans Applicant has provided information indicating they intend to provide 55,056 SF of Active Recreation Area and with a Revised Plan submission (Recreation Areas Exhibits Plan of 2/8/2023) the Active Recreation Area is now listed at 1.61 acres (70,131.6 SF). See Recreation Plan Review Report and Addendum for additional comments. a. Any revisions to the Active Recreation Area must be incorporated into the plan drawing and data/notes listings throughout the plan set. b. The Active Recreation Area is scheduled to be reviewed by the Council 54

Paj 55

Item 5. S-23-04 Leander Lakes III Apartments Site Plan DAC Report of February 8, 2023 Page 8 of 11 Committee of the Whole: Parks, Recreation & Community Enhancement Committee on February 14, 2023. 2) Upright curbing shall be provided around all parking and drive areas in accordance with the requirements of the Zoning Ordinance unless a waiver is granted by the City Planner. Clarify if type of curbing proposed. 3) Sheet 1 – Cover Sheet: a. List greater detail of Recreation Areas size area of each amenity proposed. b. List height of proposed apartment buildings. c. List maximum lot coverage in setbacks listing. d. Cite source of wetlands delineation. e. Check status/zoning of property of Farm Lands LP (adjacent property to the south). If it is in Agricultural Lands Preservation, then there are additional notes statements and a buffer that must be added to the plan. i. Add Note: “This property is in the vicinity of an established agricultural preservation district in which normal agricultural uses and activities have been afforded the highest priority use status. It can be anticipated that such agricultural uses may now or in the future involve noise, dust, manure and other odors, the use of agricultural chemicals and nighttime farm operations. The use and enjoyment of this property is expressly conditioned on acceptance of any annoyance or inconvenience which may result from such normal agricultural uses and activities.” 4) Sheet 2 – Existing Conditions Plan: Add note referencing the Conditional Use Site Plan C-19-06 Calvary Baptist Church for proposed development of the residual area (Lot 1). a. Additional coordination with the Church’s Site Plan will be necessary to revise development in northeast corner of site where Toulson Terrace entrance drive is proposed including relocation of tree plantings, stormwater management area s (drainage swale), etc. 5) Sheet 3 – Preliminary Site Plan: a. Clarify type of curbing for parking lots and drive aisles. b. Identify accessible ramps and curb depressions for access to rear emergency access lanes. c. Identify surface material and width of walkway trails. d. Add traffic control signage for fire lanes; points of intersection of Porter Place with Toulson Terrace and Isabelle Isle; and handicapped parking signage locations. e. Identify or note the number of dumpsters to be accommodated in each enclosure. 6) Please provide one or more detail sheets depicting required site details, including but not limited to bike racks, Dumpsters, stormwater, and utility details, etc. 7) Please detail any lighting proposed for this site. Show locations to ensure parking lot and walkway/paths have adequate lighting and include any lights on the buildings. 8) Sheet 4 – Preliminary Landscape Plan: a. Identify specific tree species for proposed trees. 55

Paj 56

Item 5. S-23-04 Leander Lakes III Apartments Site Plan DAC Report of February 8, 2023 Page 9 of 11 b. Identify any landscape planting plan around each apartment building. c. Tree placements providing shade to recreation amenity areas is encouraged. d. Show required demarcation shrub plantings for rear emergency access lanes. e. Please be aware of placement of any trees/landscaping with regards to any underground utilities/storm water management systems and rear emergency access lanes. 9) Provide the distance from the edge of parking/drive aisles to each apartment building. Also provide dimensions of typical parking spaces and width of access areas to rear emergency access lanes from parking lot. 10) Provide detail on the bridge or culvert crossings of Porter Place at the non-tidal wetlands/stream (two locations). Documentation of appropriate Permits for these crossing will also be required. 11) Include a detailed outline of the linear feet of walking path and specific breakdown of the active recreation areas. 12) Note the number of bicycle parking spaces to be provided. Add detail of bike rack. 13) Signs are subject to a separate review and approval process in the City of Dover. However, advice may be given on the locations of freestanding signs if they are included on the Site Plan. The proposed location of Apartment Complex signage on the adjacent church will need additional review for compliance. 14) Any Erosion & Sediment Control Plans and Stormwater Management Plans granted approval by the Kent Conservation District must reflect the Site Plan layout and design conditionally approved by the Planning Commission and be in compliance with the Zoning Ordinance and technical review requirements of other agencies. 15) Sheet 4 – Preliminary Subdivision Plat (Record Plan): A separate Record Plan sheet was submitted to show the minor subdivision of the 25 acres from the main parcel. a. The Record Plan must include cross access easements, any easements, or other items affecting the property lines. b. Add cross access easement for entrance drive connection on Church property. c. Add cross access easement for Leander Lakes III across Leander Lakes (for access to Dover High Drive). d. Label permanent easements and/or right-of-way dedications along Forrest Avenue (from C-19-06 Record Plan). 16) The Applicant must also provide their response to the PLUS Review comments. 17) The Final Plan set must include notes documenting any action taken by the Planning Commission regarding any requested waivers and must list any additional conditions of approval. 56

Paj 57

Item 5. S-23-04 Leander Lakes III Apartments Site Plan DAC Report of February 8, 2023 Page 10 of 11 X. RECOMMENDATIONS SUGGESTED AS CONDITIONS OF APPROVAL TO MEET CODE OBJECTIVES: In accordance with the Zoning Ordinance, Article 10 §2.2, the Planning Commission in considering and acting upon Site Development Plans may prescribe appropriate conditions and safeguards so that the public health, safety, and welfare, the comfort and convenience of the public in general, and the residents of the immediate neighborhood in particular shall be taken into consideration. These safeguards may to the maximum extent possible further the expressed intent of the Zoning Ordinance and the accomplishment of several objectives in particular listed in subsections 2.21 to 2.28. 1) Bicycle Parking: Planning Staff would encourage some of bicycle parking facilities to be either covered or otherwise provided at locations interior to the Apartment Buildings. 2) Electric Vehicle Charging: Planning Staff encourages this project to include the installation of Electric Vehicle Charging Stations in its parking lot. Currently, the Zoning Ordinance does not require them, but many other jurisdictions have implemented such requirements. Electric Vehicle Charging Stations formats include EV-Capable, EV- Ready, and EV-Installed. XI. ADVISORY COMMENTS TO THE APPLICANT: 1) The Planning Commission should act upon the request for any waivers as part of any motion regarding this project application, or as a separate motion as necessary. Note: All waivers are at the discretion of the Planning Commission. The Commission may approve or deny waiver requests. 2) In the event, that major changes and revisions to the Site Development Plan occur in the finalization of the Site Plan contact the Department of Planning and Inspections. Examples include relocation of site components like paving and increases in floor area. These changes may require resubmittal for review by the Development Advisory Committee, Planning Commission, or other agencies and commissions making recommendations regarding the Plan. 3) Other agencies and departments which participate in the Development Advisory Committee may provide additional comments related to their areas of expertise and code requirements. 4) Following Planning Commission approval of the Site Development Plan, the Plan must be revised to meet all conditions of approval from the Development Advisory Committee or as otherwise noted. A Check Print must be submitted for review by Planning Office Staff and the other commenting agencies. Upon determination that the Plan is complete and all agency approvals have been received, copies of the Plan may be submitted for final endorsement (Final Plan Approval). 5) For building new construction, the requirements of the building code and the fire code must be complied with. Consult with the Chief Building Inspector and City of Dover Fire Marshal for these requirements. The resolution of these items may impact the site design 57

Paj 58

Item 5. S-23-04 Leander Lakes III Apartments Site Plan DAC Report of February 8, 2023 Page 11 of 11 including such items as building dimensions and height, building openings, and fire protection needs, etc. 6) The applicant/developer shall be aware that prior to any development or ground disturbing activities on the site the appropriate site inspections and permits are required. This includes activities to clean-up existing vegetation, the import of fill dirt, etc. 7) The addresses for the new buildings proposed on the property will need to be confirmed with the City’s Tax Assessment Office. The existing address of 2285 Forrest Avenue may be retained for the proposed church on the property. Each apartment building will be addressed using the named drive aisle of Toulson Terrace and Porter Place. 8) The applicant/developer shall be aware that prior to any ground disturbing activities on the site the appropriate Site Plan approvals, Pre-Construction meetings, site inspections and permits are required. 9) The applicant shall be aware that Site Plan approval does not represent a Building Permit and associated construction activity permits. A separate application process is required for issuance of a Building Permit from the City of Dover. Building Permits will be required for each building. 10) The applicant shall be aware that Plan approval does not represent a Sign Permit, nor does it convey permission to place any sign on the premises. Any proposed site or building identification sign may require a Sign Permit from the City of Dover prior to placement of any such sign in accordance with Zoning Ordinance, Article 5 §4. If you have any questions or need to discuss any of the above comments, please call the above contact person and the Planning Department as soon as possible. 58

Paj 59

Item 5. CITY OF DOVER DEVELOPMENT ADVISORY COMMITTEE APPLICATION REVIEW COMMENTARY STAFF D.A.C. MEETING DATE: FEBRUARY 1, 2023 APPLICATION: Leander Lakes III Apartments FILE #: S-23-04 REVIEWING AGENCY: City of Dover Department of Public Works and Water & Wastewater CONTACT PERSON: Jason A. Lyon, P.E., Director of Water & Wastewater / Engineering Services CONTACT PHONE #: 302-736-7025 CONTACT PHONE #: jlyon@dover.de.us T HE S UBJECT P ROPOSAL HAS BEEN R EVIEWED FOR C ODE C OMPLIANCE , P LAN C ONFORMITY AND C OMPLETENESS IN A CCORDANCE WITH THIS A GENCY ’ S A UTHORITY AND A REA OF E XPERTISE . T HE F OLLOWING I TEMS HAVE BEEN I DENTIFIED AS E LEMENTS W HICH N EED TO BE A DDRESSED BY THE A PPLICANT : CITY AND STATE CODE REQUIREMENTS SANITATION 1. Every commercial customer shall provide such premises with a sufficient number of solid waste containers to provide adequate capacity for the solid waste placed out for collection without overloading the capacity of the containers. The City of Dover shall provide commercial customers with a maximum of two (2), 90-gallon trash containers and two (2), 90-gallong recycling containers. 2. Trash collection site shall be oriented for side-loading pick-up if customer is utilizing City of Dover sanitation services. 3. Any commercial customer requiring more containers, or larger containers, than provided above, must utilize private service. STORMWATER 1. Final site plan approval will not be granted until a copy of the approved Stormwater/Erosion and Sediment Control Plan from Kent Conservation District / DNREC is submitted to our office. 2. The size, length, slope, type and flow directions must be shown on all existing and proposed storm sewer lines. Rim and invert elevations must be labeled on all stormwater structures. 3. The stormwater infrastructure proposed for this project shall be privately maintained. STREETS 1. Final site plan approval will not be granted until a copy of the approved entrance plan, signed by DelDOT is submitted to our office. 2. The internal street network for this property will be privately owned and maintained. WATER 1. All water utility components must meet the requirements of the Water Wastewater Handbook, effective date March 22, 2010. Please contact our office for more information. 59

Paj 60

Item 5. Leander Lakes III Apartments File #: S-23-04 February 1, 2023 Page 2 of 4 2. The following notes must be added to the plans: a. Hydrant connections by the contractor are prohibited. This method may not be utilized during any phase of the project. b. Any existing water lines not to be utilized by the proposed facility must be properly abandoned at the mains in accordance with the City of Dover Department of Water & Wastewater specifications and requirements. c. The site contractor shall contact the City of Dover Department of Water & Wastewater Construction Manager at (302) 736- 7025 prior to the start of construction. A representative from the City of Dover Department of Water & Wastewater must observe and approve all City owned water and sanitary sewer interconnections and testing. All water taps must be performed by a City of Dover approved contractor. The proposed location for the water connection may need to be adjusted in the field due to conditions of the existing main. Possible conditions that would require tapping relocation include proximity to pipe joints, other taps, concrete encasements, conflict with other utilities, and the like. Test holes must be performed by the contractor to determine the best tapping location. The City of Dover will not be held responsible for field conditions requiring adjustment of the tapping location or for any work required by the contractor to make an appropriate and lawful connection. 3. The size, type, and location of all proposed and existing water lines and valves must be shown on the plan. 4. Water usage projections (peak demand or plumbing fixtures) must be submitted to our office to correctly determine the size of the domestic and irrigation (if applicable) water meter for the proposed building. These projections must be submitted prior to approval so the meter size can be placed on the final site plan. The proposed water meter must be installed in a pit per City of Dover requirements and manufacturer’s recommendations. Also, a dual check valve is required downstream of the meter. 5. The domestic service, fire main connection and valves must be clearly shown for each building. A valve must be installed at the tee to isolate combined fire and domestic water service to the building from the water loop. Typically, this valve is installed at the tee or an acceptable distance from the building. A valve must be provided on the domestic water service, which must be tapped off of the combined eight-inch (8”) fire/domestic service outside of the building. The domestic water tap and valve should be as close to the building as possible. Typically, the domestic tap and valve are located within five feet (5’) to ten feet (10’) of the building. A blow up detail of this layout is recommended. 6. Provide a construction detail for the proposed restraining system for the fire main located within the buildings. The Department of Public Works will test and inspect all fire mains to a blind flange located inside the buildings. The blind flange with tap is used for hydrostatic pressure testing (200 psi for two (2) hours) and dechlorination. The flange must be restrained in the direction of the pipe entering the facility. A pipe entering horizontally through a wall sleeve shall be restrained with rods through the wall. A pipe entering vertically through a slab shall be restrained through the floor to the ninety degree (90 ) bend and thrust block. All rods shall be a minimum of ¾” all thread. All pipes through walls and slabs must be Class 52 cement lined ductile iron pipe. Confirm particulars to meet this requirement with mechanical designer. 7. Water services shall be either type K copper or SDR-9. 8. On October 24, 2022, City of Dover Council approved the new Cross Connection Control Program. This program requires certain backflow prevention assemblies on water service connections to the city’s distribution system. This project will require a double check valve assembly to be installed downstream of the water meter in the building. 9. Please provide a detailed section of the water main crossing the existing ditch. 10. Please provide a note for the water main to tap the existing water main with a Powerseal 3490AS Tapping Sleeve and Valve. 11. Please provide any connection plan to the adjacent property to the north. As the plan stands now, the water infrastructure shall be privately owned and maintained. WASTEWATER 1. All wastewater utility components must meet the requirements of the Water Wastewater Handbook, effective date March 22, 2010. Please contact our office for more information. 2. The following notes must be added to the plans: a. Any existing sanitary sewer lines not to be utilized by the proposed facility must be properly abandoned at the mains in accordance with the City of Dover Department of Water & Wastewater specifications and requirements. 60

Paj 61

Item 5. Leander Lakes III Apartments File #: S-23-04 February 1, 2023 Page 3 of 4 b. Part II, Chapter 180, Article III, Section 180-10 of the Code of Kent County requires that “no person shall discharge or cause to be discharged any stormwater, surface water, uncontaminated groundwater, roof runoff, subsurface drainage, uncontaminated noncontact cooling water or unpolluted industrial process waters to any sanitary sewer”, this shall include condensate. Sec. 110-231 of the City of Dover Code defines storm sewer as “…any system used for conveying rain water, surface water, condensate, cooling water or similar liquid wastes, exclusive of sewage.” The contractor, developer, owner and designers shall ensure during construction that no illegal discharges to the sanitary sewer system are created with the site improvements. 3. The size, length, slope, type and flow directions must be shown on all existing and proposed sanitary sewer lines. Rim and invert elevations must be labeled on all sanitary structures. 4. Cleanouts must be installed on sanitary sewer laterals within five feet (5’) of the building, one foot (1’) outside of the right-of- way and at all bends. Any cleanout located within a traffic bearing location shall be installed with a heavy duty cast iron frame and cover to prevent damage to the cleanout and lateral. 5. Sizing (flow) calculations must be submitted for all sanitary sewer laterals (other than for single-family dwellings) showing that velocity and all other requirements are met. 6. The minimum size of all sanitary sewer laterals shall be six-inch (6”). 7. Sanitary sewer laterals shall be connected directly to the main, not manholes, unless impracticable, as determined by the Department of Water & Wastewater. 8. Please provide calculations that support the existing pump station in this basin can properly accept the proposed flow from this development. If upgrades are required to the pump station, the developer will be responsible. 9. Please provide any connection plan to the adjacent property to the north. As the plan stands now, the wastewater infrastructure shall be privately owned and maintained. GENERAL 1. All existing utilities shall be adjusted to final grade in accordance with current City of Dover requirements and practices. This must be included as a note on the plan. 2. No trees may be planted within ten feet (10’) of utility infrastructure. 3. No structure may be installed within ten feet (10’) of utility infrastructure, please depict all underground utilities and structures on the utility plan sheet to confirm compliance. 4. The final site plan must be submitted in the following compatible digital formats: a. AutoCAD 2018 (.dwg format). b. Adobe Reader (.pdf format). RECOMMENDATIONS SUGGESTED AS CONDITIONS OF APPROVAL TO MEET CODE OBJECTIVES SANITATION / STORMWATER / STREETS / WATER / WASTEWATER / GENERAL 1. None. ADVISORY COMMENTS TO THE APPLICANT WATER 1. The City of Dover water system is available to this site. The developer is responsible for all costs associated with extending and providing service to the proposed development. 2. Prior to plan approval, the water system plans must be submitted to the Division of Public Health, Office of Drinking Water for review and approval. The owner/developer will be responsible for providing all completed forms and plan sets to the City of 61

Paj 62

Item 5. Leander Lakes III Apartments File #: S-23-04 February 1, 2023 Page 4 of 4 Dover as required for submission to the Office of Drinking Water. Plans will not be submitted to the Office of Drinking Water until review has been completed by our office. 3. Hydrant flow testing is currently only performed during the spring and fall. The applicant must call the Department of Water & Wastewater directly to schedule these tests. This applies to both existing hydrants as well as those proposed for the site. 4. Water impact fees may be required to be paid prior to Certificate of Occupancy for this project. WASTEWATER 1. The City of Dover sanitary sewer system is available to this site. The developer is responsible for all costs associated with extending and providing service and capacity to the proposed development. 2. Prior to plan approval, it may be required to submit the sanitary sewer system plans to the DNREC, Division of Water Resources, Surface Water Discharges Section for review and approval. The owner/developer is responsible for providing all application fees, completed forms and plan sets directly to DNREC. 3. Wastewater impact fees may be required to be paid prior to Certificate of Occupancy for this project. GENERAL 1. The applicant is advised that depending upon the size of the existing water service and sanitary sewer lateral to be abandoned, flowable fill may be required. 2. Construction plans will not be reviewed by our office unless all previous comments have been clearly addressed within the plan set and accordingly identified within an itemized response letter and with the Water/Wastewater Initial Plan Submission Checklist, which can be obtained from the following website: https://imageserv9.team- logic.com/mediaLibrary/198/WaterWastewaterHandbookFinal_1.pdf, page 88. SANITATION / STORMWATER / STREETS 1. None I F Y OU H AVE A NY Q UESTIONS OR N EED TO D ISCUSS ANY OF THE A BOVE C OMMENTS , P LEASE C ALL THE A BOVE C ONTACT P ERSON AND THE P LANNING D EPARTMENT AS S OON AS P OSSIBLE . 62

Paj 63

Item 5. CITY OF DOVER ELECTRIC DEVELOPMENT ADVISORY COMMITTEE APPLICATION REVIEW COMMENTARY STAFF D.A.C. MEETING DATE: FEB 1, 2023 APPLICATION: Leander Lakes III Apartments FILE #: S-23-04 REVIEWING AGENCY: City of Dover Electric Department CONTACT PERSON: Shawn Burgett, Engineering Services & System Ops Superintendent CONTACT PHONE #: 302-674-7568 CONTACT EMAIL #: sburgett@dover.de.us T HE S UBJECT P ROPOSAL HAS BEEN R EVIEWED FOR C ODE C OMPLIANCE , P LAN C ONFORMITY AND C OMPLETENESS IN A CCORDANCE WITH THIS A GENCY ’ S A UTHORITY AND A REA OF E XPERTISE . T HE F OLLOWING I TEMS HAVE BEEN I DENTIFIED AS E LEMENTS W HICH N EED TO BE A DDRESSED BY THE A PPLICANT : CITY AND STATE CODE REQUIREMENTS ELECTRIC 1. The roadway and curbing must be in. 2. The right-of-way must be within 6" of final grade. 3. The property corners must be staked. 4. Owner is responsible for locating all existing underground electric, communications and water facilities. 5. Owner is responsible for installing all conduits and equipment pads per the City of Dover Engineering Department specifications. 6. Owner is responsible for site and/or street lighting. 7. Meter locations will be determined by City of Dover Engineering Department. 8. Load sheets and AutoCAD compatible DXF or DWG diskettes of site plans, including driveways, are required prior to receiving approved electrical construction drawings. 9. Any relocation of existing electrical equipment will be engineered by the City of Dover Electric Department. Developer may be required to perform a quantity of the relocation. Any work performed by the City of Dover will be at the owner’s expense. 10. Prior to construction, owner is responsible for granting an easement to the City of Dover Electric Department. Easement forms will be furnished and prepared by the City of Dover Electric Engineering Department. 11. Fees will be assessed upon final site plans. The owner will be responsible for fees assessed prior to construction. Owner is required to sign off plans prepared by the Electric Department. 12. Must maintain 10' clearance around all electrical equipment, unless pre-approved by the City of Dover Electric Engineering Department. 63

Paj 64

Item 5. Leander Lakes III Apartments File #: S-23-04 Feb 1, 2023 Page 2 of 2 13. Prior to the completion of any/all designs and estimates, the owner is responsible for providing the Electric Engineering Department with a physical address of the property. 14. All Engineering and design for Dover Electric will be engineered upon final approved plans. All Engineering work will be furnished by the City’s Electric Engineering Department. RECOMMENDATIONS SUGGESTED AS CONDITIONS OF APPROVAL TO MEET CODE OBJECTIVES ELECTRIC 1. Owner must give the City of Dover Electric Department three (3) months’ notice prior to construction. Owner is responsible for following the requirements outlined in the City of Dover’s Electric Service Handbook. The handbook is now available on the website at the following link: https://evogov.s3.amazonaws.com/media/27/media/13108.pdf. ADVISORY COMMENTS TO THE APPLICANT ELECTRIC 1. Provide load sheets as soon as possible for proper sizing of transformers and creation of primary fee estimates. Current load sheets can be found at the following link: https://www.cityofdover.com/media/Electric%20Department/COD%20Electric%20Load%20Sheet.pdf. I F Y OU H AVE A NY Q UESTIONS OR N EED TO D ISCUSS ANY OF THE A BOVE C OMMENTS , P LEASE C ALL THE A BOVE C ONTACT P ERSON AND THE P LANNING D EPARTMENT AS S OON AS P OSSIBLE . 64

Paj 65

C F S-23-04 Item 5. I I T R CITY OF DOVER Y E DEVELOPMENT ADVISORY COMMITTEE O M F A APPLICATION REVIEW COMMENTARY R D.A.C. MEETING DATE: 02/01/23 D S O H V A E L APPLICATION: Leander Lakes III Apartments R FILE #: S-23-04 REVIEWING AGENCY: City of Dover, Office of the Fire Marshal CONTACT PERSON: Jason Osika, Fire Marshal PHONE #: (302) 736-4457 THE SUBJECT PROPOSAL HAS BEEN REVIEWED FOR CODE COMPLIANCE, PLAN CONFORMITY, AND COMPLETENESS IN ACCORDANCE WITH THIS AGENCY’S AUTHORITY AND AREA OF EXPERTISE. THE FOLLOWING ITEMS HAVE BEEN IDENTIFIED AS ELEMENTS WHICH NEED TO BE ADDRESS BY THE APPLICANT: CITY AND STATE CODE REQUIREMENTS: 1. Proposed occupancy classification is residential/apartments. 2. Building Access shall be no further than 50 feet from a primary entrance Where buildings are provided with an automatic sprinkler system installed in accordance with NFPA 13, access shall be no further than 100 feet from the primary entrance. (2021 Delaware State Fire Prevention Regulations, 705, Chapter 5, 3.4) 3. Parking shall be prohibited in front of the primary entrance for a width of not less than 1.5 times the width of the door(s) or for 10 feet, whichever is greater. (2021 Delaware State Fire Prevention Regulations, 705, Chapter 5, 6.3.2) 4. Perimeter access shall be 75% and clearly shown on the plans. Perimeter Access minimum width shall be10 feet for one-story buildings and 15 feet for buildings of two or more stories, measured from the face of the building at grade with a maximum slope of ten percent (10%). Plantings and utility services (includes condenser units, transformers, etc.) shall be permitted within the perimeter access, and shall not interfere with emergency services fire ground operations. If a physical barrier (fence, pond, steep slope, etc) prevents access, that portion of the building perimeter shall not be included in the calculation of Percent of Perimeter Access. (2021 Delaware State Fire Prevention Regulations, 705, Chapter 5, 3.5) Where parking is located between the building and perimeter access area, parking shall not be located closer than 10 feet to the exterior wall for one-story buildings and 15 feet to the exterior wall for building of two or more stories. 5. Fire lanes shall cover 35% of the proposed building. 65

Paj 66

Item 5. Fire lanes are required to be 24 feet wide and run along the front of the building as determined by the primary entrance(s). In cases where there is more than one primary entrance(s), each shall be served by a fire lane even if this exceeds the percentage as required. The closest edge of fire lanes shall not be located closer than ten (10) feet to the exterior wall and the closest edge of fire lanes shall not be located further than 50 feet from the exterior wall if one or two stories in height; 40 feet if three or four stories in height, or 30 feet if over four stories in height. (2021 Delaware State Fire Prevention Regulations, 705, Chapter 5) 6. Where parking is located between the building and the fire lane, parking shall not be located closer than 15 feet to the exterior wall. (2021 Delaware State Fire Prevention Regulations, 705, Chapter 5, 6.4.1) 7. All Fire Lanes shall be marked as follows: both the inner and outer edges of the fire lane shall be marked, where curbs are present, the top and face of the curb shall be painted yellow, where no curbs are present, a four inch (4”) solid yellow demarcation line shall mark the edge(s) of the fire lane. (2021 Delaware State Fire Prevention Regulations, 705, Chapter 5, 7) 8. The specific color yellow shall be the uniformly accepted yellow as utilized by State of Delaware Department of Transportation (DelDOT). Only vivid and durable paint shall be used and shall be suitable for street surfaces 9. Fire lane signs shall be located as follows: see Figure 5-16 – Approved Sign For Marking Fire Lanes, fire lane signs shall be spaced at 150 foot intervals maximum, all fire lane signs shall be located no less than six feet (6’) and no higher than eight feet (8’) above the pavement, signs shall be placed at each end of the fire lane, and signs shall face all oncoming traffic. Where parking is not restricted roadway markings shall utilize the words "FIRE" and "LANE" in lieu of fire lane signs and shall conform to the specifications of 7.6. (2021 Delaware State Fire Prevention Regulations, 705, Chapter 5, 7) 10. Where overhangs, canopies, balconies, or any other building or site features must project over any fire lane, an unobstructed vertical clearance of not less than 13’-6” above the fire lane shall be provided and the portion of the building perimeter which contains overhangs, canopies, balconies, or any other building features shall not apply towards the fire lane accessibility requirements of Section 4.0, Table 5-1 in this chapter. (2021 Delaware State Fire Prevention Regulations, 705, Chapter 5, 6.8) 11. Emergency access to rear building areas compliant with City of Dover Code (Appendix B-Zoning, Article 5- Supplementary Regulations, Section 17); all four stories and greater buildings require 24ft fire lane at the rear. All two to three story apartment structures require an 18ft Secondary Fire Lane at the rear. All townhouses (3-8 units with no fire protection) require a 16ft alley or 18ft secondary fire lane at the rear. 66

Paj 67

Item 5. 12. Multiple Access Roads shall be provided when a fire department access road (fire lane) is determined by the Fire Marshal to be impaired by vehicle congestion, condition of terrain, climatic conditions, or other factors that could limit access such as placement of fire hose from fire equipment. 13. Street width shall be in accordance with City of Dover Code of Ordinances, Appendix A, Article VII, Section A. 13, Residential areas 24 feet wide with no parking, 30 feet wide with parking on one side, or 36 feet wide with parking on both sides Commercial areas 26 feet wide with no parking, 32 feet wide with parking on one side, or 38 feet wide with parking on both sides Alley 12 feet wide 14. Speed Reduction Devices must be approved, please see City of Dover Ordinance Chapter 98-10 in reference to this process. 15. Fire hydrants shall be installed per the requirements of City of Dover Public Utilities Water/Wastewater Handbook, NFPA requirements, and Delaware State Fire Prevention Regulations. City Ordinance Sec 46-9 (f). 5.1.1 Hydrant spacing as shown in the Fire Flow Tables shall be used as a general rule. Hydrants shall be located at the direction of the State Fire Marshal so as to minimize friction in fire hose. All hydrant spacing shall be located along available roads or at the direction of the State Fire Marshal. This measurement shall be calculated by way of accessible thoroughfare(s) from the building to be protected to the hydrant and may not necessarily be a radius. 5.1.3 Additional hydrants shall be provided when the State Fire Marshal deems it necessary based on the configuration of the site, building(s), exposures, construction, occupancy, and/or specific hazard(s). Fire Flow table 2, hydrant spacing shall be 800 feet on center for one and two family detached dwellings, other residential, rowhouses and townhouses, assembly, health care, business, education, storage, industrial, mercantile, and mini storage. (702, Chapter 6) 16. All fire hydrants shall be marked as prescribed within the appropriate section of this regulation and as illustrated by the appropriate figures of this regulation. All fire hydrants shall have minimum of four-inch (4") solid yellow demarcation lines to define specific areas, where fire hydrants are located along a curb line with permitted parking, the area between the fire hydrant and the street or fire lane shall be stenciled with four inch (4") demarcation lines and the words "NO PARKING", demarcation lines shall be measured from the center line of the fire hydrant and extend for a distance 15 feet on both sides. Where fire hydrants are located in parking lots or other areas susceptible to blockage by parked vehicles they shall be treated as follows: fire hydrants shall be protected in all directions for a distance of seven feet (7') with barriers or curbing, Minimum four-inch (4") diameter steel bollards filled with concrete and marked yellow shall be installed at the outermost corners of the fire hydrant demarcation area. The minimum height of the bollard shall be 36 inches above the finished grade of the adjacent surface, and the steamer connection of all fire hydrants shall be positioned so as to be facing the edge of the street, or traffic lane. (2021 Delaware State Fire Prevention Regulations, 705, Chapter 6, 2) 67

Paj 68

Item 5. The owner is responsible if the hydrant is private. 17. Hydrant barrels shall be provided with reflective material, such as paint, durable for highway/roadway markings or a reflective tape of a minimum of 2” in width around the barrel under the top flange, hydrant bonnets shall be color coded based on the following criteria: class AA 1500 GPM - painted light blue, class A 1,000 GPM -1499 GPM - painted green, class B 500 - 999 GPM - painted orange, class C 250 - 499 GPM - painted red, class D under 250 GPM - painted black. (2021 Delaware State Fire Prevention Regulations 703, Chapter 3. 4) The owner is responsible if the hydrant is private. 18. Hydrants are to be Darling Co. B-62-B Breakaway https://american-usa.com/products/valves-and- hydrants/fire-hydrants/5-1-4-american-darling-b-62-b-5 19. NFPA 72 compliant Fire Alarm System required per occupancy code requirements. Fire alarm in place of assembly. Fire alarm required. Any new occupancy or new portion of an occupancy determined to be a place of assembly by the fire marshal and is capable of receiving an occupant load of 75 persons or greater, shall be required to install a fire alarm in accordance with NFPA codes governing the installation of fire alarms and the National Electrical Code. Fire alarm system required. Any existing occupancy or portion of an existing occupancy determined to be a place of assembly by the fire marshal, and is undergoing renovations in excess of 50 percent of the assessed value of the building and is capable of receiving an occupant load 75 persons or greater or is being enlarged to receive an occupant load of 75 persons or greater, shall be required to install a complete fire alarm system in accordance with NFPA codes governing the installation of fire alarms and the National Electrical Code. Public mode audible requirements. To ensure that audible public mode signals are clearly heard by occupants of a structure, they shall have a sound level at least 15 decibels (dB) above the average ambient sound level or five decibels (dB) above the maximum sound level having a duration of at least 60 seconds, whichever is greater, measured five feet (1.5m) above the floor in the area required to be served by the system using the A-weighted scale dBA. In the event the stated requirement cannot be met a shunt trip relay/switches shall be the approved method of meeting the intent of this section of the Code. (City Code of Ordinances 46-171) 20. Sprinkler system required. System is to be monitored by an approved Fire Alarm System. This chapter shall apply to all buildings, structures, marine vessels, premises, and conditions which are modified by more than 50% after the effective date of these Regulations. The 50% figure shall be calculated utilizing the gross square footage of the building, structure, marine vessel, premises and conditions as to arrive at the correct application. Any proposal that is presented to the Office of the State Fire Marshal for review and approval for a building rehabilitation as defined in the 101 Life Safety Code, for less than 50% of the gross square footage of a non-sprinklered building, may not have another such project for the same building submitted for review and approval any sooner than three (3) years after the date of the final inspection unless sprinkler projection is provided throughout the entire building. In all buildings exceeding 10,000 square feet of aggregate, gross floor area. In all buildings in excess of 40 feet in height or more than four (4) stories in height. In all buildings or areas thereof used for the storage, fabricating, assembling, manufacturing, processing, display or sale of combustible goods, wares, merchandise, products, or materials when more than two (2) stories or 25 feet in height. In all basement areas exceeding 2,500 square feet floor area. 68

Paj 69

Item 5. In residential occupancies when of: Type V (0,0,0) or Type III (2,0,0) construction and exceeding two (2) stories or 25 feet in height. Type V (1,1,1) and Type III (2,1,1) or Type IV (2,H,H) construction exceeding three (3) stories or 3In all residential apartment buildings storage areas except individual unit closets that are located within individual residential living units. In all buildings used as health care occupancies as defined in the Life Safety Code, NFPA 101, as adopted and/or modified by these Regulations. In all buildings or areas classified as "high hazard" under the Life Safety Code, NFPA 101, or "extra hazard" under the Standard for the Installation of Sprinkler Systems, NFPA 13, as adopted and/or modified by these Regulations. All buildings used as dormitories, in whole or in part, to house students at a public or private school or public or private institution of higher education. (16 Del.C. Ch. 88) This applies to all such dormitories regardless if new or existing. (2015 State of Delaware fire Prevention Regulations, 702, Chapter 4) Places of assembly shall be sprinklered throughout in accordance with the most recently adopted edition of NFPA 13 when the following apply: All new indoor places of assembly with an occupant load of 150 persons or greater. Any interior renovations of 50 percent or more to an existing place of assembly with an occupant load greater than 150 persons. Any additions or increase in interior size to an existing place of assembly that would create an occupant load of 150 persons or greater. Places of assembly where alcohol is served for consumption on the premises shall be sprinklered throughout in accordance with the most recently adopted edition of NFPA 13 when the following apply: All new indoor places of assembly with an occupant load of 100 persons or greater and where alcohol will be served for consumption on the premises. Any interior renovation of 50 percent or more to an existing place of assembly with an occupant load greater than 100 persons and where alcohol will be served for consumption on the premises. Any additions or increase in interior size to an existing place of assembly which would create an occupant load of 100 persons or greater and where alcohol will be served for consumption on the premises. New educational occupancies of 5,000 square feet or greater shall be sprinklered throughout in accordance with the most recently adopted edition of NFPA 13. (City of Dover Code of Ordinances 46-162) 21. Fire Department Connection is to be a 5-inch stortz connection on a 30-degree elbow located within 50 feet of main entrance. Access to the Fire Department Connection must be clear unobstructed access as defined by the AHJ. Fire department connections. Unless otherwise approved by the fire marshal, fire department connections shall be on the street side of the building and shall be located and arranged so that hose lines can be readily and conveniently attached to without interference from any nearby obstructions as defined by the fire marshal's office. Fire department connections shall be a five- inch Storz. Fire department connections shall be within 300 feet of an approved City of Dover Fire Hydrant and within 50 feet of the main entrance of the structure it serves. All fire department connections shall be not less than three feet nor more than five feet in height above finished grade. 69

Paj 70

Item 5. The fire marshal shall have the authority to require more stringent requirements when deemed necessary. (City of Dover Code of Ordinances 46-162) 22. Parking and/or obstructions shall be prohibited in front of fire department connections for a distance measuring from the center line and extending four feet on both sides. (2015 Delaware State Fire Prevention Regulations, 705, Chapter 5, 6.3.4) 23. Fire Department Connection to be located within 300 feet of fire hydrant, measured as hose would come off the fire equipment. 24. All standpipe and sprinkler connections shall be marked as prescribed within the appropriate section of this regulation and as illustrated by the appropriate figures of this regulation. All standpipe and sprinkler connections shall have minimum of four inch (4") solid yellow demarcation lines to define specific areas, Solid yellow demarcation lines shall be measured from the center line of the connection and extend for a distance of four feet (4') on both sides, and where parking is allow between the building and the street or fire lane the solid yellow demarcation lines shall extend from the end of the sidewalk surface to the street or fire lane (Markings shall not be required on the sidewalk surface). All fire department connections (standpipe and sprinkler) shall have a minimum 12" x 18" sign that reads FIRE DEPT. CONNECTION, sign lettering shall be a minimum of 3 inches (3") in height with red scotchlite letters on white scotchlite background. The sign shall be clearly visible from the fire lane or roadway, and signs using NFPA international symbols shall be an acceptable alternative. (2021 Delaware State Fire Prevention Regulations, 705, Chapter 6, 3) 25. Standpipes shall be provided in all areas and buildings as required in the codes and standards listed in Regulation 701 as well as the following areas or buildings: In all Class A and Class B places of assembly and institutional occupancies two (2) stories or 25 feet in height or over, In any building over three (3) stories, In any building over 35 feet in height, In any building that has a floor above the first floor over 10,000 square feet gross floor area, In all buildings where the 1st floor exceeds 60,000 gross square feet, a Class I horizontal standpipe system installed in accordance with the applicable codes and standards listed in Regulation 701 of these Regulations shall be provided. All standpipe systems shall be installed in accordance with the applicable codes and standards listed in Regulation 701. The standpipe system shall be carried up with each floor and shall be installed and ready for use as each floor progresses. Standpipes shall not be more than one floor below the highest forms of staging, The 2½-inch of hose connections on Class I systems shall be provided in the following locations, At the highest intermediate landing between floor levels in every required exit stairway, Where intermediate landing is not provided, hose connections shall be permitted to be located at the main floor landings in exit stairways when approved by the authority having jurisdiction, Where the local fire department has the capability of providing the required pressure, hydraulically designed standpipe systems in fully sprinklered, non-high-rise buildings shall be designed to provide the required waterflow rate. 70

Paj 71

Item 5. A sign shall be provided at each landing, in all interior stairways, designating the floor level. (2021 Delaware State Fire Prevention Regulations 702, Chapter 4, 2) 26. The installation of natural gas and LP gas meters, regulators, valves, and LP gas bottles shall be protected from impact damage by impact protection. Natural gas and LP gas meters, regulators, and valves located inside structures shall have impact protection, except when located in separate protected utility rooms. Dimensions of bollards. Bollards shall be a minimum of six-inch diameter filled with concrete. The bollard shall be set into the ground at a depth of at least 36 inches (three ft.) embedded in concrete at a minimum of 18 inches surrounding the bollard. The bollards must be a least 48 inches (four ft.) in height above the finish grade elevation. Any deviation of the stated requirements must be approved by the fire marshal and/or chief building inspector. The above dimensions shall serve as the requirement for installation; however, the fire marshal and/or chief building inspector shall have the authority to require more stringent dimensions to fit the needs of devices warranting impact protection. Color of bollards. Bollards should be of the following colors; yellow, amber or orange. All colors shall be of fluorescent or have a reflective coating. Any deviation of the stated requirements must be approved by the fire marshal and/chief building inspector. (City of Dover Code of Ordinances, 46-4) 27. Every house, building or structure used or intended for use as living quarters or as a place for conducting business, and having any wall facing or abutting any public or private street or alley, shall have displayed on that wall, in legible, easily read characters which are of contrasting color to the background, the proper street number for such house, building, or structure in accordance with the following: One-family and two-family residential structures, height, the number shall measure a minimum of four inches in height, location, the number shall be placed on the house above or to the left or right of the front entrance, color, the number shall be contrasting to the background color, Arabic numerals, all numbers shall be Arabic numerals. Multiple-family dwellings, measurements, the number shall measure a minimum of six inches when identifying individual apartments with exterior doors, and 12 inches when identifying buildings with apartment complexes where there are two or more buildings not assigned street addresses. Individual buildings with street addresses shall have numbers measuring six inches, location, numbers shall be placed either in the center of the building or on the street end of the building so as to be visible from either the public or private street or from the parking lot, color, numbers shall be contrasting to the background color, Arabic numerals, all numbers used shall be Arabic numerals. Commercial, industrial and office buildings, height, the numbers shall measure a minimum of 12 inches in height, location generally, numbers shall be placed either in the center of the building or on the street end of the building so as to be visible from either the public or private street or from the parking lot, property line or driveway, should the building be located far enough from a public or private road so that the numbers are not clearly visible from the street, then the street address shall also be posted on the property at or near the property line or driveway to said building, color; each building, numbers shall be contrasting to the background color and shall be placed on each building in the complex, Arabic numerals, all numbers used shall be Arabic numerals, 71

Paj 72

Item 5. Shopping centers. Shopping centers consisting of two or more stores shall have a tenant or suite number affixed to the front of the tenant space and on the outside of the rear door which corresponds with that tenant space. Numbers shall measure six inches in height. (City of Dover Code of Ordinances, 98-344) 28. A lock box (Knox) containing any and all means necessary for fire department access shall be provided at the following occupancies: any occupancy that contains a fire alarm signaling system that is monitored off-site, or any occupancy that contains an automatic sprinkler system. (2021 Delaware State Fire Prevention Regulations 705, Chapter 5, 2.4) Secured key systems. When required; exemption. A secured key system shall be required for any new or existing building where a fire alarm or sprinkler system is being installed. It shall be the responsibility of the owner or occupant to keep a set of keys in the secured key box that are current to the locks of the protected occupancy. Buildings with 24-hour staffing or guard service shall be exempt from this subsection. Location. The secured key system shall be located as close to the main entrance as possible. Should the building design not allow the secured key system to be located by the main entrance, the fire marshal and fire chief shall come to an agreement as to an alternate location for the key box. A secured key system, once installed, shall not be obstructed from view or obstructed by any means that would delay the fire department access to the box. Required keys. Keys to be secured in the key box shall include keys to all points of ingress or egress, whether on the interior or exterior of the building, and keys to locked mechanical rooms, electrical rooms, elevator rooms, fire alarm and sprinkler controls and any area protected by automatic fire detection. Keys to individual residential apartment units are not required. Ordering responsibility. It shall be the responsibility of the general contractor to order the key box for new buildings. It shall be the responsibility of the owner or tenant to order the key box for existing buildings. Installation before testing. No acceptance test for sprinklers or fire alarms shall be conducted before the installation of a key box. (City Code of Ordinances 46-127) Knox Box to be mounted 6 feet above ground level 29. All required means of egress shall have an exit discharge consisting of a non-slip surface and leading to and terminating at a public way. NFPA 101 30. Buildings over 25,000 Sq. Ft are to have radio performance testing done by Delaware State Communications prior to Final CO. This must be scheduled in advance with Delaware State Communications. 31. Project to be completed per approved Site Plan. 32. Full building and fire plan review is required. 33. Separate building permits/plans submission will be required for each building and/or tenant fit out. If the permit submission is for a “shell” a Certificate of Occupancy will not be issued. Separate plans and permits submissions will be required for each “tenant fit out” at which time a Certificate of Occupancy will be issued upon compliance/completion of each “tenant fit out”. 72

Paj 73

Item 5. Each “shell” will require a fire permit for sprinkler and fire alarm if applicable. Those systems (for the “shell”) must be accepted into service prior to any “tenant fit out” fire permits being issued. 34. Construction or renovations cannot be started until building plans are approved. 35. Fire alarm systems, fire suppression systems, hoods, exhaust ducts, and hood suppression systems require a fire permit from the Fire Marshal’s Office. This work cannot be started until the permit is approved. 36. Building cannot be occupied by the public until a Certificate of Occupancy is obtained. 37. The following is City Ordinance, Appendix B-Zoning, Article 8 Enforcement and Penalties: Section 1. - Building permits. No building or structure in any district shall be erected or structurally altered without a building permit duly issued upon application to the building inspector. No building permit shall be issued unless the proposed construction or use is in full conformity with all the provisions of this ordinance. Any building permit issued in violation of the provisions of this ordinance shall be null and void and of no effect, without the necessity for any proceedings for revocations or nullification thereof, and any work undertaken or use established pursuant to any such permit shall be unlawful (see section 4 for penalties). 1.1 No building permit shall be issued for the construction or alteration of any building upon a lot without frontage upon, or legal permanent access to, a public street improved to the satisfaction of the planning commission, or without access to a public sewer. 1.2 No building permit shall be issued for any building where the site development plan of such building is subject to approval by the planning commission, except upon approval of such plans approved by the said commission. 1.21 No building permit shall be issued for any building in a subdivision unless the subdivision plot has been approved by the planning commission. 1.3 No building permit shall be issued for a building to be used for any conditional use in any zone where such use is allowed only with approval of the planning commission, unless and until such approval has been duly granted by the said commission. (Ord. of 7-12-1993, § 3) ADDITIONAL / SPECIFIC REQUIREMENTS TO OBTAIN APPROVAL: 1. Please confirm that the roadways/Fire Lane is 24’ 2. Please confirm that there is 15’ spacing between the building and the parking 3. Emergency access to rear building areas shall be compliant with City of Dover Code Appendix B-Zoning, Article 5- Supplementary Regulations, Section 17 for construction and identification 4. A discussion will be needed in reference to fire hydrant location/spacing APPLICABLE CODES LISTED BELOW (NOT LIMITED TO): 2021 NFPA 1 Fire Code (NFPA; National Fire Protection Association) 2021 NFPA 101 Life Safety Code (NFPA; National Fire Protection Association) 2019 NFPA 72 National Fire Alarm and Signaling Code (NFPA; National Fire Protection Association) 2019 NFPA 13 Installation of Sprinkler Systems (NFPA; National Fire Protection Association) 2009 IBC (International Building Code) Latest editions of all other NFPA Codes as defined by the Delaware State Fire Prevention Regulations 2021 Delaware State Fire Prevention Regulations City of Dover Code of Ordinances *If you have any questions or need to discuss any of the above comments, please call the above contact person listed. 73

Paj 74

Item 5. CITY OF DOVER D E DEVELOPMENT ADVISORY COMMITTEE L APPLICATION REVIEW COMMENTARY D O T =============================================================== APPLICATION: Leander Lakes III Apartments FILE#: S-23-04 REVIEWING AGENCY: DelDOT CONTACT PERSON: Joshua Johnson PHONE#: 302-760-2141 =============================================================== THE SUBJECT PROPOSAL HAS BEEN REVIEWED FOR CODE COMPLIANCE, PLAN CONFORMITY AND COMPLETENESS IN ACCORDANCE WITH THIS AGENCY'S AUTHORITY AND AREA OF EXPERTISE. THE FOLLOWING ITEMS HAVE BEEN IDENTIFIED AS ELEMENTS WHICH NEED TO BE ADDRESSED BY THE APPLICANT: CITY & STATE CODE REQUIREMENTS: No person, firm, corporation or the like shall construct, open, reconstruct, maintain, modify or use any crossing or entrance onto a state-maintained highway, street or road, including any drainage modifications leading into or carried by the highway drainage system, without first having complied with standards and regulations adopted by the Department and having obtained a permit issued by the Department. Please contact the Delaware Department of Transportation - Development Coordination section to begin permit process. RECOMMENDATIONS SUGGESTED AS CONDITIONS OF APPROVAL TO MEET CODE OBJECTIVES: ADVISORY COMMENTS TO THE APPLICANT: 1. DelDOT held a coordination meeting with the applicants on December 21, 2022. DelDOT anticipates this project will follow the standard Record Plan/Entrance Plan process. 74

Paj 75

KENT CONSERVATION DISTRICT Item 5. 1679 SOUTH DUPONT HIGHWAY • DOVER, DELAWARE 19901• (302) 608-5370 • WWW.KENTCD.ORG CITY OF DOVER DEVELOPMENT ADVISORY COMMITTEE APPLICATION REVIEW COMMENTARY FEBRUARY 2023 APPLICATION: Leander Lakes III Apartments FILE #: S-23-04 REVIEWING AGENCY: Kent Conservation District CONTACT PERSON: Kate Owens PHONE: (302) 608 – 5370 EMAIL: stormwater@kentcd.org THE SUBJECT PROPOSAL HAS BEEN REVIEWED FOR CODE COMPLIANCE, PLAN CONFORMITY AND COMPLETENESS IN ACCORDANCE WITH THIS AGENCY’S AUTHORITY AND AREA OF EXPERTISE. THE FOLLOWING ITEMS HAVE BEEN IDENTIFIED AS ELEMENTS WHICH NEED TO BE ADDRESSED BY THE APPLICANT: Source: 2019 Delaware Sediment and Stormwater Regulations CITY AND STATE CODE REQUIREMENTS: 1. As the disturbance for this site will exceed 5,000 square feet, a detailed sediment and stormwater management plan must be reviewed and approved by the District prior to any land disturbing activity (i.e. clearing, grubbing, filling, grading, etc.) taking place. The review fee and a completed Application for a Detailed Plan are due at the time of plan submittal to the District’s office. 2. A pre-application meeting is required prior to submitting plans. Please contact the District’s office to schedule. 3. The following notes must appear on the record plan: a. The Kent Conservation District reserves the right to enter private property for purposes of periodic site inspection. b. The Kent Conservation District reserves the right to add, modify, or delete any erosion or sediment control measure, as it deems necessary. c. A clear statement of defined maintenance responsibility for stormwater management facilities must be provided on the Record Plan. ADVISORY COMMENTS TO THE APPLICANT: 1. The existing stormwater design from the approved plans for Calvary Baptist Church has drainage swales and dual 24” HDPE pipes near the proposed site’s entrance road that is not shown on the proposed plans. Proposed grading and drainage must account for the approved grading and drainage for Calvary Baptist Church. 2. A letter of no objection to recordation will be provided once the detailed Sediment and Stormwater Management Plan has been approved. 75

Paj 76

Item 5. City of Dover DATA SHEET FOR RECREATION PLAN REVIEW Review of Active Recreation Area Plan With Addendum PARKS, RECREATION AND COMMUNITY ENHANCEMENT COMMITTEE MEETING OF February 14, 2023 PLANNING COMMISSION MEETING of February 21, 2023 Plan Title: Leander Lakes III Apartments Plan Type: Active Recreation Area Associated with Site Development Plan and Minor Subdivision Plan S-23-04 Location: South side of Forrest Avenue west of Dover High Drive Address: Unaddressed off Forrest Avenue (Part of Property at 2285 Forrest Avenue) Tax Parcel: ED-05-075.00-01-06.00-000 Owner: Calvary Baptist Church of Dover Equitable Owner/Developer: Leander Lakes III, LLC. Project Area: 25 +/- acres (Project area) Zoning: RM-2 (Medium Density Residence Zone and partially subject to COZ-1 (Commercial Overlay Zone) Present Use: Vacant land Proposed Use: Lot 2 Area: Garden style Apartment Buildings Dwelling Units: 200 units Recreation Area: Required – 55,000 SF (1.26 +/- acres) Provided – 55,000 SF (1.26 +/- acres) P. O. Box 475 Dover, DE 19903 76 Community Excellence Through Quality Service

Paj 77

Item 5. S-23-04: Leander Lakes III Apartments Active Recreation Area Plan Review for Parks and Recreation Meeting With Addendum of February 10, 2023 February 14, 2023 Page 2 of 8 ADDENDUM The Applicant submitted a Revised Recreation Areas Exhibit Plan Sheet dated February 8, 2023. The Revised Plan sheet included a detail listing of the Recreation Areas and materials for the recreation amenities. See attached Plan Sheet. Revised Active Recreation Area Plan – Leander Lakes III Apartment The following are key revisions of the Recreation Area Plan: • The total area is listed as 1.61 acres. • Playground (South) has been changed to a Fitness Area with Yoga & Free Workout space and equipment (pull-up bars, bench/body curl, parallel bars, balance beam, and step- up/dip bars. • Revisions made to walking trails/pathways to connect directly to recreation amenities. • Playground (North) equipment features revised to include slide, swings, quad climber, and tetter-totter. • Detailed listing of the Recreation Areas and their sizes (area of). • Detailed listing of the surface materials proposed for the recreation areas. With this Revised submission the Applicant has address some of the review comments identified in the Recreation Area Review Report. The following Active Recreation Area Review Report was prepared and issued for the Council Committee of the Whole – Parks, Recreation & Community Enhancement Committee Meeting scheduled for February 14, 2023. The additional information on the Revisions will be presented at their Meeting. 77

Paj 78

Item 5. S-23-04: Leander Lakes III Apartments Active Recreation Area Plan Review for Parks and Recreation Meeting With Addendum of February 10, 2023 February 14, 2023 Page 3 of 8 I. PROJECT SUMMARY: The project proposes construction of eight (8) 3-story garden style apartment buildings and 1 (one) 2-story 8 unit building for a total of two hundred (200) units. Also proposed are 450 parking spaces, walking paths, landscaping, recreation areas and other site improvements. The project area of 25 acres is zoned RM-2 (Medium Density Residence Zone) and partially subject to the COZ-1 (Corridor Overlay Zone) with the balance of the overall property zoned R-10 (One Family Residence Zone and partially subject to COZ-1 (Commercial Overlay Zone). The application includes a Minor Subdivision Plan to create Lot 1 of 50.19 acres+/- (residual) and Lot 2 of 25 acres (project area). The property is located on the south side of Forrest Ave west of Dover High Drive. The owner of record is Calvary Baptist Church of Dover and equitable owner/developer is Leander Lakes III, LLC. Property is currently unaddressed on Forrest Ave. Tax Parcel: ED-05-075.00-01-06.00-000. Council District 1. II. ACTIVE RECREATION AREA PLAN SUMMARY: The Site Development Plan as submitted by the applicant for the Apartment Complex notes 4 Active Recreation features, as well as walking paths throughout the open area in the middle of the site plan. Staff estimates 12,000 square feet of active recreation area outside of the walking paths. This information is provided to show how the Site Plan submitted is achieving the aims set out in the Zoning Ordinance, Article 5 Section 10: Open space, recreation, and other public facilities. The Active Recreation Area is required at a rate of 275 SF per unit or a half-acre (21,780 SF), whichever is greater. With this project of two hundred (200) units, the Active Recreation Area requirement calculates to 55,000 SF which is greater than the half-acre (21,780 SF). The Active Recreation Areas proposed are shown on the overall Site Plan, and the calculations are not provided (Sheet 1). See Summary Table below of Active Recreation Areas. Active Recreation Area (Article 5 §10.1) Required Provided on Plan 275 S.F. per dwelling unit or ½ • Playground (North) acre (21,780 SF) whichever is • Playground (South) greater to be provided on site. • Sport Court East o Cornhole 200 DU = 55,000 SF (1.26 +/- ac) o Horseshoes Required = 55,000 SF • Sport Court West o Cornhole Provided: 55,000 SF* o Horseshoes • *Need detailed size areas • Walking Trail 1 & 2 (runs north-south) to confirm • Rear Emergency Access Lanes • Bike Racks 78

Paj 79

Item 5. S-23-04: Leander Lakes III Apartments Active Recreation Area Plan Review for Parks and Recreation Meeting With Addendum of February 10, 2023 February 14, 2023 Page 4 of 8 Article 5 Accessible The recreations are in the central portion of the site plan to §10.151 the buildings. There are 2 children’s Playground areas on opposite ends of the common space. The 2 Sports Areas are flanking the central walking path closer to the middle of the central common area. Both these types of recreation areas should have connecting sidewalks to the play areas, as well as benches for siting. 10.152 Pedestrian oriented There are walking paths outlined in the site plan. Staff would like to see measurements on the linear feet of walkways. 10.153 Age Oriented The 3 types of recreation areas outlined in the plans show child aged Playgrounds, 2 Sport Areas and walking paths. • For clarification, can the residents of the Leander Lakes III use the facilities of neighboring Leander Lakes facility (Clubhouse & Pool)? This area cannot be used towards the minimum required area for this property. 10.154 Parking The parking is provided for the buildings and the paths connect to the interior common areas, though not directly. 10.155 Walking, jogging There are 3 bike racks on the site plan, but no details and biking trails regarding the number of spaces is provided. The requirement is 1 bike space for every 20 car spaces (Article 6, Section 3 of the Zoning Ordinance). 23 minimum bike spaces should be provided in total. 10.156 Setbacks The recreation areas on these site plans appear to follow the setback requirements. 10.157 Landscaping The site requires 341 trees and there the appropriate number listed on the plan. Specific tree species will need to be identified on the plans and signed off by a Landscape Architect as per Zoning Ordinance. • The Landscape Plan does not show tree plantings up the entire proposed entrance road Toulson Terrace. Calvary Church Plan C-19-06 has the tree plantings stopping at the line of the COZ zone. The trees proposed could continue from the COZ-1 line to the apartment complex area to create a tree lined drive. 10.158 Area The breakdown of the allotted recreation areas is not listed on the site plans. The Sport Court areas appear to be the minimum 2000 square feet. • Please provide how the minimum required space has been accomplished. • Need to know if the Emergency Access Lanes counting towards the minimum recreation area. 79

Paj 80

Item 5. S-23-04: Leander Lakes III Apartments Active Recreation Area Plan Review for Parks and Recreation Meeting With Addendum of February 10, 2023 February 14, 2023 Page 5 of 8 III. REVIEW PROCESS The Planning Office has prepared this Active Recreation Area Report outlining the Recreation Area proposal. The Parks, Recreation and Community Enhancement Committee will need to consider the proposed Active Recreation Area and make a recommendation. The Planning Commission must act to accept the Recreation Area Plan as part of the Site Plan review process. The Parks, Recreation and Community Enhancement Committee will review the Recreation Area Plan at their meeting on February 14, 2023. The Planning Commission Public Hearing and Review of the Site Development Plan S-23-04 and the Recreation Area Plan is scheduled for February 21, 2023. IV. CODE CITATIONS: Dover Code of Ordinances, Appendix B – Zoning, Article 5 – Supplementary Regulations, Section 10 – Open Space, Recreation and Other Public Facilities (select excerpts). Article 5 Section 10 Section 10. - Open space, recreation, and other public facilities. The City of Dover shall require the reservation of open space, recreation, and other public facilities in accordance with the provisions of this section as a condition of approval for all one-family dwelling, two-family dwelling and multiple-family dwelling residential developments requiring conditional use approval, site development plan approval, or land subdivision approval by the City of Dover Planning Commission. 10.1 Recreation areas. 10.11 Purpose. The purpose of this section is to ensure that active recreation areas are provided as an integral design element within residential developments and that such facilities are of an adequate scale in relation to the size of the residential development and which provide residents with a variety of active recreational pursuits. 10.12 Dedication required. The commission shall require the dedication or reservation of recreation areas, and the subsequent construction of recreation facilities of a character, extent and location suitable to the needs created by a development for recreation facilities as defined and in accordance with the design guidelines set forth. 10.13 Definition. The following are illustrative of the types of recreation areas and subsequent facilities that shall be deemed to serve active recreational needs and therefore to count toward satisfaction of the recreation area requirements of this section: tennis courts, handball courts, racquetball courts, swimming pools, saunas and exercise rooms, meeting or activity rooms within clubhouses, baseball and soccer fields, basketball courts, volleyball courts, swings, slides and play apparatus, and developed walking, jogging or biking trails. 10.14 Recreation area review…. 10.15 Design guidelines… 10.16 Area required. All residential developments shall provide recreational areas in a size equal to 275 square feet per dwelling unit or one-half acre of land, whichever is greater. In no case shall the commission require that more than ten percent of the gross area of the development be so dedicated or reserved when the gross area is greater than five acres. 80

Paj 81

Item 5. S-23-04: Leander Lakes III Apartments Active Recreation Area Plan Review for Parks and Recreation Meeting With Addendum of February 10, 2023 February 14, 2023 Page 6 of 8 V. STAFF RECOMMENDATIONS The following are comments and recommendations from staff of the Planning Office following review of the Active Recreation Area Plan. 1) Provide itemized list size (dimensions) of each recreation area amenity including playground, sport court, and 2 pathway systems (walkway and rear emergency access lane path). Based on 200 units, a total of 55,000 SF of Active Recreation Area must be provided. 2) The Site Plan overall is showing pedestrian connectivity among the various buildings, amenities, and across the drive-aisles and the parking lot areas. 3) Active Recreation Area: As a residential development, there is a requirement for Active Recreation area(s). Staff Recommends the following regarding these Recreation Areas: a. Playgrounds: Plans submitted show that there are proposed features identified as playgrounds, but further information is needed as to what specific playground amenities are proposed. i. It should also be noted what material is intended for the ground cover. ii. Consider moving the south playground to the common area between Buildings F&G so it has more direct access to the parking lot. iii. Add fence or landscape barrier between south playground and nearby stormwater management pond. b. Sport Courts: The Sport Court appears to show features indicating use as a Cornhole Courts/Horseshoe Pits. Indicate the materials used for court areas. i. Connecting these areas to the walking paths would allow for wheelchair and stroller access. c. Walking Trails: One style of walking trail/path run north-south on each side of the stream interconnecting with the Rear Emergency Access Lanes (10 ft. wide concrete flanked by 4 ft. wide grass pavers for total of 18 foot width) creating a two separate loops in the central open space area. i. Identify surface material, width, and edge treatment of walking trails. d. Bicycle Parking: Bicycle parking should be located at every one of the Apartment Buildings. If any Bike Parking facilities are proposed internal to the buildings, then the Plans should note as such. i. Staff recommends adding bike racks near each recreation amenity like the south playground area. e. Pedestrian Connectivity: Staff notes that the sidewalk system could easily be extended in several locations to increase pedestrian connectivity to the overall development. i. The sidewalk along Toulson Terrace is against the entrance drive curbing. It would be more pedestrian friendly if there was a grass buffer area between the 81

Paj 82

Item 5. S-23-04: Leander Lakes III Apartments Active Recreation Area Plan Review for Parks and Recreation Meeting With Addendum of February 10, 2023 February 14, 2023 Page 7 of 8 entrance drive curb and the sidewalk. ii. Make sure to connect the bike racks and the recreation areas directly to the pedestrian paths. Make sure to add sitting benches in the playground areas as well as the sport courts. iii. Identify Lighting of walkway/path system. f. Pedestrian Facilities Internal to the Site: The layout of the proposed sidewalks internal to the site are generally good with the exception of interconnection to Leander Lake I. i. Add Pedestrian marked crossings where sidewalks continue to link to existing Leander Lakes Apartments (crossing of Isabelle Isle). g. Sidewalk Cuts: No curb cuts or ramps shown on sidewalks or near street crossings; add accessible ramps. h. Adequate Lighting for the Site: It appears in the plan that the light fixtures are only at the building side of the parking lots. Please detail the light fixtures to be used and add lighting to the back side of the parking lots as necessary. i. Landscaping: Specific tree species will need to be identified on the plans and signed off by a Landscape Architect as per Zoning Ordinance. 4) Clarify if residents of Leander Lakes III will have access to Clubhouse and Pool facilities located in Leander Lakes I (existing apartment complex to the east). VI. ADVISORY COMMENTS 1) This Site Development Plan set depicting the Recreational Areas are to include appropriate improvements, plans, and details of the Active Recreation Area as approved. 2) There shall be provisions which ensure that the community space (all areas under consideration for Active Recreation Areas) shall continue as such and be properly managed and maintained. The developer shall either retain ownership and responsibility for maintenance of the common use areas or provide for and establish one (1) or more organizations for the ownership and maintenance of all common space i.e., a Homeowners Association or other property management entity. The organization shall be responsible for maintenance, insurance, and taxes on the community space. 3) In the event, that major changes and revisions to the Plan occur in the finalization of the Plan contact the Planning Office. Examples include reorientation of buildings, relocation of site components, changes in floor area or unit count, or design revisions impacting Active Recreation Areas. These changes may require resubmission for review by the Development Advisory Committee, Planning Commission, or other agencies and commissions making recommendations in regard to the plan. 4) The Parks, Recreation, and Community Enhancement Committee shall submit to the Planning Commission a report detailing the recommendations as to the Recreation Area Plan. 82

Paj 83

Item 5. S-23-04: Leander Lakes III Apartments Active Recreation Area Plan Review for Parks and Recreation Meeting With Addendum of February 10, 2023 February 14, 2023 Page 8 of 8 Attachments: • Site Plan S-23-04 Leander Lakes III Apartments. Select Sheets 1, 3, and 4. • Example of Building Elevation Sheet (A1-201) 83

Paj 84

Item 5. FORRES T AVEN UE (SR8 OW ) 69.4'± R EX. EASEMENT, PLAT REF.: 145/60 N PROPOSED SITE SIGNAGE RECREATION AREAS: RECREATION AREA MATERIALS: 25' WIDE LANDSCAPE 303 North Bedford Street FITNESS AREA, YOGA & FREE WORKOUT: 0.48 AC,± FITNESS AREA, YOGA & FREE WORKOUT: MULCH / GRASS BUFFER Georgetown, DE 19947 PULL UP BARS, BENCH/BODY CURL, PULL UP BARS, BENCH/BODY CURL, T. 302.297.9215 PARELLEL BARS, BALANCE BEAM, PARELLEL BARS, BALANCE BEAM, 3003 Merritt Mill Road STEP UP, DIP BARS STEP UP, DIP BARS Salisbury, MD 21804 T. 410.572.8833 PLAYGROUND: 0.06 AC.± PLAYGROUND: MULCH www.solutionsipem.com Copyright © 2023 SLIDE, SWINGS, QUAD CLIMBER, SLIDE, SWINGS, QUAD CLIMBER, 4 SEATER TEETER TOTTER 4 SEATER TEETER TOTTER CORNHOLE / HORSE SHOES 0.15 AC.± CORNHOLE / HORSE SHOES GRASS / CONCRETE PAD / SAND PIT PATH/TRAIL (1240 L.F.±) 0.20 AC.± PATH/TRAIL CRUSHED STONE PROPOSED WALKING TRAIL/ WALKING TRAIL/ SITE SIGNAGE EMERGENCY ACCESS LANE 0.72 AC.± EMERGENCY ACCESS LANE CONCRETE / GRASS PAVERS PROPOSED (3045 L.F.±) VARIABLE WIDTH TOTAL RECREATION 1.61 AC.± ACCESS Seal EASEMENT REQUIRED: 275 S.F. PER UNIT = 275 x 200 Date 01/05/23 = 55,000 S.F. / 1.26 AC.± 5' WIDE MATCH LINE LANDSCAPE N/F BUFFER WITHIN CALVARY BAPTIST CHURCH OF SEE HEREON THE COZ-1 CULVERT TO BE DOVER DELAWARE, INC. ZONING BIKE RACK PROVIDED AT 2-05/07500-01-0600-000 WETLAND CROSSING DB 2323/116 PLAT REF.: 145/60 PROPOSED PROPERTY ZONED: R10 & COZ-1 LINE (TYP.) DESCRIPTION BIKE RACK PORTER PLACE PORTER PLA REVISIONS SD CE S 8SS ISABELL TOULSON TERR 24 UNIT E ISLE PROPOSED PROPERTY BUILDING D LINE (TYP.) 24 UNIT ACE BUILDING C 8 UNIT BUILDING E PLAYGROUND 8SS CORNHOLE DATE COURTS/ R HORSESHOE 23'± N BUFFE DRIVE R PITS BUFFER LANE N BUFFE 24 UNIT R CORNHOLE BUILDING A NO. RIPARIA RIPARIA COURTS/ SED 50' C/ RIPARIA O HORSESHOE 8SS N BUFFE PITS RIPARIA TOULSON TERR EX. 100' PORTER PLACE N SED 50' 18' WIDE REAR EMERGENCY EX. 100 ACCESS LANE PROPO ' PROPO S 8SS LEANDER LAKES III SW M ACE 24 UNIT PATH/TRAILS EXISTING CITY OF DOVER BUILDING F LEANDER LAKES ISAB LE ISLE ISABELL APARTMENT RECREATION AREAS EXHIBIT E L N/F SW LEANDER LAKES APARTMENTS, LLC SD M 2-05-07500-01-0501-000 E ISLE DB 9413/315 SD for 24 UNIT KENT COUNTY, DELAWARE BUILDING B 8SS YOGA AREA S C/ O FREE WORKOUT AREA 24 UNIT BUILDING G FITNESS AREA 24 UNIT 24 UNIT BUILDING H BUILDING I MATCH LINE BIKE RACK SEE HEREON G22066 AS NOTED ML JE JE 2/8/23 ISABELLE ISLE Job Number: Designed By: Approved By: PORTER PLACE Drawn By: SD Date: Scale: GRAPHIC SCALE Sheet No.: 60 30 60 120 240 3 0 N/F 50.00' AGRICULTUR CULVERT TO BE PROVIDED AT FARM LANDS, LP File Name: 2-00-07500-01-3200-000 ( IN FEET ) 22066-recreat-areas WETLAND CROSSING DB 237-279 1 inch = 60 ft. ZONED: AC 84 SETBACK (AGRICULTURAL USE WITHIN

Paj 85

Item 5. LANDSCAPE BUFFER NOTES: LANDSCAPE SCHEDULE FORRES 1. THE LANDSCAPE AND/OR FOREST BUFFERS SHALL BE INSTALLED WITHIN 18 MONTHS FROM THE DATE SITE T AVEN WORK IS AUTHORIZED TO COMMENCE, AS DOCUMENTED BY A NOTICE TO PROCEED LETTER FROM THE QUANTITY SYMBOL TYPE SIZE UE (SR8 OW COMMISSION. 147 D DECIDUOUS TREE 1 21" CAL., 6' HGT. MIN. ) 69.4'± R 2. THE LAND DEVELOPER SHALL BE RESPONSIBLE FOR THE HEALTH AND SURVIVAL OF THE TREES, INCLUDING 139 E EVERGREEN TREE 5' HGT. MIN. REGULAR NECESSARY WATERING FOR A MINIMUM OF 2 YEARS OR UNTIL SUCH LATER DATE AS THE EX. EASEMENT, MAINTENANCE RESPONSIBILITIES ARE TRANSFERRED TO A HOMEOWNER'S ASSOCIATION; PROVIDED, HOWEVER PLAT REF.: 145/60 THAT THE DEVELOPER SHALL REPLACE AND TREES THAT DIE DURING THE MINIMUM 2 YEAR DEVELOPER 81 SE SCREENING EVERGREEN 5' HGT. MIN. MAINTENANCE PRIOR TO TRANSFERRING MAINTENANCE RESPONSIBILITIES TO A CONDOMINIUM ASSOCIATION. LANDSCAPE: REQUIRED: 1 TREE PER 3000 FT. 3. ADDITIONAL INFORMATION AS TO HOW THE LANDSCAPE / FORESTED BUFFERS ARE TO BE MAINTAIN IN 30' B.R 1021046.4 / 3000 = 340.35 - 341 TREES REQUIRED. .L . PERPETUITY, SHALL BE INCLUDED IN THE RESTRICTIVE COVENANTS AND/OR HOMEOWNER'S ASSOCIATION DOCUMENTS. 1D PROVIDED: 1D 4. PURSUANT WITH SUSSEX COUNTY CODE SECTION 99-5, THE 20' WIDE LANDSCAPE BUFFER SHOWN IN THIS EVERGREEN SPECIES - 220 1D PLAN MUST BE PLANTED WITH A MIX OF 70% DECIDUOUS AND 30% EVERGREEN TREES, THE MAJORITY OF DECIDUOUS SPECIES - 147 WHICH SHALL BE SUITABLE TREES OF COMMON LOCAL SPECIES. EVERY 100' OF BUFFER SHALL INCLUDE A TOTAL = 367 25' WIDE MINIMUM OF 15 TREES. 1D LANDSCAPE 303 North Bedford Street 5. ALL DECIDUOUS TREES THAT ARE PLANTED TO ESTABLISH THE BUFFER PLANTINGS SHALL HAVE A MINIMUM SITE DATA: BUFFER 1D Georgetown, DE 19947 T. 302.297.9215 CALIPER OF 1.5 INCHES AND A MINIMUM HEIGHT OF SIX FEET ABOVE GROUND WHEN PLANTED IN ORDER TO INSURE THAT THE TREES WILL BE CAPABLE OF OBTAINING A MINIMUM HEIGHT OF 10 FEET ABOVE GROUND 3003 Merritt Mill Road OWNER OF CALVARY BAPTIST CHURCH OF DOVER DELAWARE, INC. WITHIN FIVE YEARS OF BEING PLANTED. Salisbury, MD 21804 RECORD: 410 FULTON STREET T. 410.572.8833 6. ALL EVERGREEN TREES THAT ARE PLANTED TO ESTABLISH THE BUFFER PLANTINGS SHALL HAVE A MINIMUM DOVER, DE 19904 1D www.solutionsipem.com Copyright © 2022 HEIGHT OF FIVE FEET ABOVE GROUND WHEN PLANTED IN ORDER TO INSURE THAT THEY ARE REASONABLY CONTACT: DR. CHARLES D. FLETCHER, JR. CAPABLE OF ATTAINING A MINIMUM HEIGHT OF 10 FEET ABOVE GROUND WITHIN FIVE YEARS OF BEING PLANTED. 1D EQUITABLE LEANDER LAKES III, LLC OWNER: 218 EAST MAIN STREET 7. THE TREES SHALL BE PLANTED IN A STAGGERED NATURAL MANNER. THE PROCEDURES AND DETAILS FOR N PLANTING NEW TREES SHALL BE SPECIFIED BY THE LANDSCAPE ARCHITECT ON THE PLAN SUBMITTED TO AND SALISBURY, MD 21801 APPROVED BY THE COMMISSION AND SHALL INCLUDE THE REQUIREMENT THAT THE BUFFER AREA SHALL HAVE CONTACT: BLAIR RINNIER, CCIM, CPM A FINAL GRADE THAT CONTAINS A MINIMUM OF FOUR INCHES OF TOPSOIL AND A SUITABLE GRASS MIX 1D PLANTED AS SACRIFICIAL COVER BETWEEN THE BUFFER TREES FOR SOIL STABILIZATION UNTIL THE NEWLY ENGINEER: SOLUTIONS IPEM PLANTED TREES BECOME LARGER. THE PLAN MAY SUBSTITUTE WOODCHIPS FOR PLANTED GRASS BETWEEN THE EVERGREEN TREE PLANTING DETAIL 303 NORTH BEDFORD STREET BUFFER TREES IN RESPECT TO BOTH NEWLY PLANTED AND EXISTING TREES, AS DETERMINED BY THE LANDSCAPE GEORGETOWN, DE 19947 ARCHITECT DECIDUOUS TREE PLANTING DETAIL CONTACT: JIM ERIKSEN, PE 1D 8. ALL EROSION AND TREE PROTECTION MEASURES SHALL BE PLACED AT THE DRIPLINE WHEN TREES ARE TO REMAIN. LANDSCAPE: BRIDGMAN LANDSCAPE ARCHITECTURE LLC 920 STARR ROAD 1D Seal 9. ALL TREES SHALL HAVE A ONE-YEAR REPLACEMENT GUARANTEE. CENTREVILLE, MD 21617 410-490-3651 Date 01/05/23 CONTACT: LEE A. SCHNAPPINGER BRIDGMAN 5' WIDE 10' B.R.L. MATCH LINE LANDSCAPE 1D BUFFER WITHIN 20' B.R.L. N/F CALVARY BAPTIST CHURCH OF SEE HEREON THE COZ-1 DOVER DELAWARE, INC. 1D ZONING 2-05/07500-01-0600-000 DB 2323/116 PLAT REF.: 145/60 1D 11E ZONED: R10 & COZ-1 12D BE 7SE TR NC N AV HM DESCRIPTION 5E 20' B.R.L. 5D 1D E: : 42 ER AR 3D EL 60 104 SE P K 7SE 3D EV 97 6 I .= 33. .63 N S 46 00 ET 6E 8W COZ-1 .3 PORTER PLA 2D CORRIDOR OVERL 6 REVISIONS 8W CE AY ZONE LINE 1D 8W S 8W 8W 5E 8W SS SS SS S 8W SS S 8SS IS TOULSON TERR 8W 4D 8W ISAABELL BELLEEISISLLEE 24 UNIT BUILDING D 8W W 3D 3E 24 UNIT ACE BUILDING C 3D 7E 8 UNIT 3D BUILDING E 3D 8SS DATE 7SE S S SS W WV R 8W 4E 8W 23'± 3D 8W 7D 7E N BUFFE R DRIVE BUFFER LANE N BUFFE 24 UNIT SS NO. 3E 2D 7E BUILDING A 5E RIPARIA N BUFFE 3E 3D SED 50' C/ RIPARIA R O 8SS 6SE 3D 5D RIPARIA TOULSON TERR EX. 100' SS RIPARIA PORTER PLACE N SED 50' 5E EX. 100' T PROPO 20' B.R.L. PROPO 5D 8W 8W SS S 8W 8SS LEANDER LAKES III SW 6E ACE M 7D 24 UNIT EXISTING SS PRELIMINARY LANDSCAPE PLAN 4E CITY OF DOVER BUILDING F LEANDER LAKES ISAB LE ISLE ISABELL 5SE 3D APARTMENT E 3E L N/F SW LEANDER LAKES APARTMENTS, LLC SS SD M S 2-05-07500-01-0501-000 E ISLE 20' B.R.L. 3D DB 9413/315 3D 7E 8W 8W 8W SD for S 24 UNIT SS 3D 4E KENT COUNTY, DELAWARE 3D BUILDING B 8SS 7E C/ 6SE S O SS 3D 5D 5D 3D W 6E 7E WV 8W SS 8W 8W 5SE 24 UNIT SS 11E BUILDING G XFMR T 24 UNIT 3E BUILDING H 24 UNIT 4D SS BUILDING I MATCH LINE 3E 8W 4D SEE HEREON G22066 11/23/22 AS NOTED ML JE JE 3E 8W 5D SS 26SE 8W 8W 8W 8W 8W 8W 8W 8W ISABELLE ISLE Job Number: Designed By: Approved By: 8W SS 8W SS S PORTER PLACE Drawn By: SS S SS S SS 8W Date: Scale: S S 4E 6SE 6SE GRAPHIC SCALE Sheet No.: 20' B.R.L. 3D 6D 3D 60 30 60 120 240 4 0 N/F FARM LANDS, LP File Name: 2-00-07500-01-3200-000 ( IN FEET ) 22066-prelim=land DB 237-279 1 inch = 60 ft. ZONED: AC 85

Paj 86

Item 5. Fisher Architecture, LLC 542 Riverside drive Salisbury, MD 21801 (410) 742-0238 SEAL: 1 1 A-203 A-203 SIM. provide 6" CORNER TRIM 12 12 30 YEAR ARCHITECTURAL ASPHALT 12 12 2 SHINGLES, TYPICAL.. OWNER TO 10 10 10 10 COORDINATE COLOR WITH ARCHITECT A-203 12 12 12 12 PROFESSIONAL CERTIFICATION: I CERTIFY THAT THESE DOCUMENTS WERE PREPARED OR APPROVED BY ME, AND THAT I AM A DULY 12 12 12 12 LICENSED ARCHITECT UNDER THE LAWS OF THE VERTICAL BOARD AND BATTEN STATE OF MARYLAND. VINYL SIDING @ ALL GABLE ENDS. LICENSE NO.: 0013955 TYPICAL THROUGHOUT EXPIRATION NO.: 09.23.2022 THE DOCUMENTS PREPARED BY roof bearing 8" METAL WRAPPED FASCIA BOARD. typ.FISHER ARCHITECTURE, LLC, ARE SOLELY FOR THE PURPOSES OF THE SPECIFIED PROJECT. THEY ARE NOT INTENDED OR 42" high vinyl guardrail & railing AUTHORIZED FOR USE ON ANY OTHER PROJECT. FISHER ARCHITECTURE, LLC door/wdw h.h system. SEE STANDARD NOTES MAKES NO REPRESENTATION AS TO THEIR SUITABILITY FOR ANY OTHER USE. ALL 10'-0" FOR REQUIREMENTS. TYP. DOCUMENTS PREPARED BY FISHER ARCHITECTURE, LLC ARE 7'-0" INSTRUMENTS OF PROFESSIONAL SERVICE IN 6" verticAL VINYL SIDING, COLOR TO BE RESPECT OF THE PROJECT. THESE DOCUMENTS ARE, AND SHALL REMAIN, THE CHOSEN BY OWNER, TYPICAL. PROPERTY OF FISHER ARCHITECTURE, LLC. CONSULTANTS: third floor 6" horizontal VINYL SIDING, COLOR TO BE floor bearing CHOSEN BY OWNER, TYPICAL. provide 6" CORNER TRIM 11'-0 3/4" door/wdw h.h 9'-0" PVC WRAPPED PRESSURE TREATED POST - 7'-0" REFER TO STRUCTURAL DRAWINGS. PROVIDE METAL WRAPPED TRIM AROUND second floor WINDOW AND DOOR APPLICATIONS. G.C. TO COORDINATE INSTALLED WINDOW CONDITION, floor bearing TYP. 11'-0 3/4" door/wdw h.h provide rowlock sill at top of brick water table, TYP 9'-0" 7'-0" 3'-6" brick water table, TYP first floor WRAPPED pvc SQUARE COLUMNS, BRICK WATER TABLE, TYP. WRAPPED pvc SQUARE COLUMNS, 2 PVC WRAPPED PRESSURE TREATED 2 ON EACH SIDE OF ENTRANCE. 2 ON EACH SIDE OF ENTRANCE. POST. REFER TO STRUCTURAL. PROVIDE 12" METAL WRAPPED BAND A-203 SEE FLOOR PLAN SEE FLOOR PLAN SIM. BOARD. TOP OF BAND BOARD SHALL OCEAN'S EAST APARTMENTS ALIGN WITH TOP OF DECK @ FACADE 24 UNIT BUILDING: FRONT ELEVATION 1 SCALE: 1/8" = 1'-0" 9828 SEAHAWK RD BERLIN, MARYLAND 1 1 A-204 A-204 6" VERTICAL VINYL SIDING, COLOR TO BE SIM. CHOSEN BY OWNER, TYPICAL. 30 YEAR ARCHITECTURAL 2 12 12 12 12 ASPHALT SHINGLES, TYPICAL.. A-204 OWNER TO COORDINATE COLOR 10 10 10 10 WITH ARCHITECT 2 12 12 12 12 A-204 SIM. 12 12 12 12 VERTICAL BOARD AND BATTEN VINYL SIDING @ ALL GABLE ENDS. TYPICAL THROUGHOUT 8" FASCIA BOARD. typ. roof bearing 42" high vinyl guardrail & railing door/wdw h.h system, typical.. SEE STANDARD NOTES 10'-0" FOR REQUIREMENTS. SHEET INFO: 7'-0" PROVIDE 12" METAL WRAPPED BAND BOARD. TOP OF BAND BOARD SHALL third floor ALIGN WITH TOP OF DECK @ FACADE. floor bearing 6" HORIZONTAL VINYL SIDING, COLOR TO BE BUILDING CHOSEN BY OWNER, TYPICAL. ELEVATIONS 11'-0 3/4" door/wdw h.h 9'-0" provide 6" CORNER TRIM 7'-0" second floor provide 6" trim AROUND (24 UNIT BUILDING) ALL WINDOWS AND DOORS - G.C. floor bearing to coordinate in field - TYP. 11'-0 3/4" door/wdw h.h provide rowlock sill 10 2021.10.21 UNIT REVISIONS at top of brick water table 9'-0" 8 2021.04.13 FOUNDATION REVISIONS 7'-0" oversized brick water table 7 2021.04.08 FOUNDATION UPDATES PVC WRAPPED PRESSURE TREATED PHASE 2 DOCUMENTS 6 2018.12.04 first floor POST. REFER TO STRUCTURAL. FOR OWNERSHIP REVIEW COMMUNITY BUILDING 5 2017.08.15 COORDINATION PVC WRAPPED PRESSURE TREATED 4 2017.02.24 24 UNIT BUILDING REVISIONS POST. REFER TO STRUCTURAL. Issued for Review: 3 08.26.2016 Community Building Revisions 2 07.11.2016 ISSUED FOR PERMIT 1 06.24.2016 TO OWNER FOR REVIEW DATE: 06.08.2015 PROJECT 2015045 NO. SCALE: AS NOTED PROJ. MGR: H.A.M. DRAWN T.D.E BY: SHEET NUMBER: 24 UNIT BUILDING: BACK ELEVATION 2 SCALE: 1/8" = 1'-0" A1-201 86

Paj 87

Item 6. City of Dover DATA SHEET FOR SITE DEVELOPMENT PLAN REVIEW DEVELOPMENT ADVISORY COMMITTEE MEETING OF February 8, 2023 PLANNING COMMISSION MEETING OF February 21, 2023 Plan Title: Tidal Wave Auto Spa at 245 North DuPont Highway, S-23-05 Plan Type: Site Development Plan Lot Consolidation Plan Location: Northeast of the intersection of North DuPont Highway and White Oak Road Address: Two (2) Parcels addressed as 245 North DuPont Highway, Dover DE Tax Parcel: ED-05-068.18-01-12.00-000 ED-05-068.18-01-13.00-000 Owner: TWAS Properties LLC Lot Size: Existing Parcel A: not provided Existing Parcel B: not provided Total Both Parcels: 2.15 +/- acres (88,718 SF) Total Both Parcels (after ROW dedication): 2.04 +/- acres Zoning: C-4 (Highway Commercial Zone) Present Use: Unoccupied (Previous use: Retail Building with drive-thru) Proposed Use: Car Wash (Service Establishment) Proposed Building Area: Carwash: 3,690 SF Canopy 1: not provided Canopy 2: not provided Off Street Parking: Required – 13 spaces Proposed – 41 spaces (34 Vacuum Station Parking Spaces) Sewer & Water: City of Dover Waivers Requested: None P. O. Box 475 Dover, DE 19903 87 Community Excellence Through Quality Service

Paj 88

Item 6. City of Dover CITY OF DOVER Planning Office DEVELOPMENT ADVISORY COMMITTEE APPLICATION REVIEW COMMENTARY D.A.C. MEETING DATE: February 8, 2023 APPLICATION: Tidal Wave Auto Spa at 245 North DuPont Highway FILE #: S-23-05 REVIEWING AGENCY: City of Dover Planning CONTACT PERSON: Julian Swierczek, AICP PHONE #: (302) 736-7196 I. PLAN SUMMARY This application is for review of a Site Development Plan Application and associated Lot Consolidation Plan Application for two (2) parcels totaling 2.15 +/- acres at 245 North DuPont Highway. The Plan is to permit construction of a 3,690 SF Car Wash facility, 24 vacuum spaces, and associated site improvements. The properties are zoned C-4 (Highway Commercial Zone). The parcels consist of a total of 2.15 +/- acres and is located on the northeastern corner of N. Dupont Highway and White Oak Road. The owner of record is TWAS Properties LLC. Property Addresses: 245 and 243 N Dupont Highway. Tax Parcel IDs: ED-05-068.18-01-13.00-000 and ED-05-068.18-01-12.00-000. II. PROJECT DESCRIPTION The subject properties were most recently used as retail (Rite Aid Pharmacy); however, this previous use has ceased, and the existing building is currently vacant. The subject site is currently comprised of two (2) parcels totaling 2.15 +/- acres in total, and the Plans submitted indicate that the Applicant is to consolidate the properties into one single parcel. The project proposes demolition of the existing retail building. This would allow then for the construction a new one- story 3,690 SF building to be utilized as the new Car Wash Facility as well as other site features. The Plans indicate that there are to be two (2) additional structures to the east of the proposed main building to be built. These are both to be structures to cover the thirty-four (34) Vacuum Stations proposed. With one structure providing cover to twenty-four (24) spaces to the south, and ten (10) spaces to the north, both running perpendicular to the proposed main building to the west. Surrounding Land Uses: Immediately abutting this property to the north and east are further properties also zoned C-4 (Highway Commercial Zone) containing a mix of retail uses. It is noted that these properties appear to share access drives and parking, and the Applicant has noted the existence of some easements to that effect. Across White Oak Road to the south and west of the subject site are properties also zoned C-4 and containing a mix of commercial uses as well as two single-family homes which are legal non-conforming as they were developed prior to the current zoning regulations. Across White Oak Road from the subject site to the south and east are more single-family homes on properties zoned R-7 (One-Family Residence Zone). Across North DuPont Highway to the west are properties 88

Paj 89

Item 6. S-23-05 Tidal Wave Auto Spa at 245 N. DuPont Highway DAC Report of February 8, 2023 Page 2 again zoned C-4, and containing a Restaurant (Dunkin Donuts), as well as another Car Wash Facility (Race Track Car Wash), and a Motel (Superlodge). III. ZONING REVIEW C-4 (Highway Commercial Zone) The C-4 Zoning District in the City of Dover permits the following: retail stores; business, professional, and government offices; restaurants; personal service establishments; service establishments; hotels and motels; places of public assembly; bus terminals; wholesale, storage, warehousing, and distribution establishments; indoor or outdoor recreation and amusement establishments; hospitals and medical centers; drive-throughs; motor vehicle, boat, or farm equipment service stations subject to conditions; manufacturing with less than 25 employees; and mini-storage facilities. Permitted conditionally subject to Conditional Use approval by the Planning Commission: apartments and multi-family dwellings; crematories subject to conditions. See City of Dover Zoning Ordinance, Article 3 Section 16 for more details on the C-4 zoning district. The use of a Car Wash Facility is considered a service establishment, which is a permitted use in the C-4 Zoning District. IV. PARKING SUMMARY The parking requirement for a building within the C-4 zone is one parking space per 300 SF of floor area, or one per every employee, whichever is greater. Based on floor area of 3,690 SF the facility would require thirteen (13) parking spaces. The plan appears to show a total of forty-one (41) parking spaces. This includes thirty-four (34) parking spaces with vacuum service equipment. There are also two (2) ADA vehicle parking spaces immediately abutting the proposed building to the east. Five (5) vehicle parking spaces are shown to the north of the site, accessed by the shared access-drive which runs along the north property line. The Plan identifies these as being intended as employee parking. Bicycle Parking Bicycle parking is required at a ratio of one space for every twenty parking spaces. If the site is to be served by 41 parking spaces, three bicycle parking spaces are required. Currently, none are shown on the Plans submitted but the applicant has stated that a bicycle parking rack will be provided. The Zoning Ordinance, Article 6 Section 3.10 does allow for the Applicant to request a Waiver from the requirements to provide bicycle parking from the Planning Commission, provided the Applicant can demonstrate that bicycle parking would not be appropriate for safety reasons or due to the nature of the use of the site V. SITE CONSIDERATIONS Access There are two points of existing vehicle access to the site from the adjacent shared circulation system. There is an existing shared access drive from North DuPont Highway. This provides access to a Drive Aisle which runs along the north property line of the subject site. There is an existing entrance to the parking areas existing on-site from this shared access drive, but this subject Application is proposing moving this entrance from the west end (closer to North DuPont Highway) to further east. There is another two-way entrance existing at the southeast corner of the site which currently provides vehicle access to the adjacent property immediately to the east of the subject site. No change is proposed to this vehicle access point. 89

Paj 90

Item 6. S-23-05 Tidal Wave Auto Spa at 245 N. DuPont Highway DAC Report of February 8, 2023 Page 3 The new location of the vehicle access point along the north access drive provides connection to the drive thru lanes where vehicles may cue for the drive-thru car wash. The vehicle access point at the southeast corner of the project site which in turn provides access from the adjacent property to the east. There is a one-way drive-aisle which runs parallel to the east property line (south to north) which connects the two access points. This Drive Aisle along the east property line provides access to the vehicle parking and vacuum stations located internal to the site via a two-way drive aisle which encompasses these facilities. There is otherwise no direct connection from either North DuPont Highway or White Oak Road to the drive aisles or parking areas internal to the site. Sidewalks Sidewalks are required along all street frontages (Zoning Ordinance, Article 5 §18). The plan shows an existing sidewalk along the North DuPont Highway frontage, which is to be removed. In its place, the Applicant is proposing a new 5-foot wide sidewalk, which appears to include a sidewalk connection into the site. The Applicant is similarly proposing to replace the existing sidewalk along the White Oak Road frontage to the south with a 5-foot wide sidewalk, which in turn also is showing a sidewalk connection onto the site. While there is a connection from the sidewalks along both the North DuPont Highway and White Oak Road frontages shown, these sidewalks are connecting to vehicle only infrastructure on-site without any paths identified for pedestrians to access the proposed building, parking areas or other site features. There is an existing sidewalks connection off North DuPont Highway along the north property line, providing pedestrian access to the properties to the east of the subject Site. This sidewalk is to be removed, with a new sidewalk connection off North DuPont Highway that would connect to where vehicles would cue to enter the Car Wash. It appears to be at the widest point of these drive-aisles, where vehicle would have to turn and there is a concern about visibility here. There is also no pedestrian crossing shown across the drive aisle, but it does appear that a pathway for this sidewalk to again connect to the east property lines exists; however, it is shown to cross the drive aisle a total of three (3) times before making said connection. The sidewalk connecting from the White Oak Road frontage from the south similarly connects to a drive aisle but has no pedestrian path clearly visible connecting from this point to any of the on-site features. This sidewalk connects at a point where vehicles exit the Car Wash and two drive aisles connect, being an area of heavy vehicle traffic. Lighting Article 5 §7.1 stipulates that lighting shall provide no less than 1.5 foot-candles at grade. Light shall be deflected away from adjacent residential areas and shall not be distracting to traffic on adjacent roads. The Lighting scheme has been shown on Plan Sheet C-301. Dumpsters There is not a specific Dumpster requirement for this type of use. A Dumpster enclosure is proposed off the drive aisle which runs parallel to the east property line, as shown in the site Plan (Plan Sheet C-301). The number of dumpsters to be contained are not identified, nor is the method of trash collection. 90

Paj 91

Item 6. S-23-05 Tidal Wave Auto Spa at 245 N. DuPont Highway DAC Report of February 8, 2023 Page 4 Some details are provided in the Elevation Drawing submitted in conjunction with the Site Plan. This appears to indicate that the overall aesthetic of the exterior of the Dumpster Enclosure is in keeping with the overall design of the main building (Carwash). Both the Elevation Plan Sheet and Site Plan Sheet note that the presence of a smaller gate providing access to what appears to be a short series of ascending steps within the Dumpster Enclosure. Curbing The upright curbing for the parking lots and drive aisles are subject to the requirements of Article 6 Section 3.6(b) of the Zoning Ordinance. The Applicant appears to show curbing along all paved areas throughout the site, however no details of the curbing have been provided. Such details will need to be provided to determine if the curbing height is in compliance. VI. BUILDING ARCHITECTURE The Plan submission includes Elevation Drawings. These color drawings depict all four elevations of the proposed 1-story Car Wash Facility building and identifies the materials proposed. The Building overall appears to be comprised primarily of glass walls, with certain facades containing flat surfaces painted in a dark gray. These are accented by the corners being covered in a light gray stone veneer in the upper areas, and a watertable around the lower portions of the walls of a warmer brown stone veneer. The proposed building runs parallel to North DuPont Highway. The façade facing North DuPont Highway appears to be almost entirely composed of glass (with the exception of the stone veneer on the north and south corners) though the material which appears as glass is not explicitly identified under the Exterior Materials Legend. The building is capped by a gabled roof which is noted as being of a dark blue metal material. There is an Elevation Sheet containing a building layout and two Elevation Drawings of the proposed roof structure over the (24) Vacuum Stations proposed running parallel to White Oak Road. This structure is open on all four sides and shows a series of dark metal beams supporting a blue metal roof similar to that of the main building to the west. The Site Plan notes this canopy structure sheltering 24 total stations (12 along both the south and north sides of the structure), with an enclosed space to the west end to contain some of the vacuum equipment. The elevations do not depict any of the Vacuum Equipment, nor the enclosed space towards the west end of the canopy The Elevation Drawings also appear to only show 11 spaces on either side (22 total). No information is provided for the additional covered parking area for the ten (10) Vacuum Stations to the north shown on the Site Plan, but it may be similar to the main Vacuum Canopy depicted. VII. TREE PLANTING AND LANDSCAPE PLAN The submitted plan set includes a concept for the Landscaping Plan (Sheet C-701). The Stated development area is 2.04 +/- acres (88,718 SF), which would require thirty (30) trees to meet the tree density requirements. However, the Site Overall appears to be 2.15 +/- acres, which coincides with the Plans’ stated “Area of Disturbance.” 2.15 +/- acres would equate to roughly 93,654 SF, which would require a total number of thirty-two (32) trees to be planted. The Applicant must clarify the Lot Area overall (in both acreage and square feet) to verify the total number of tree plantings required. The Landscape Plan submitted with their overall submission (Sheet C-701) which identifies (32) 91

Paj 92

Item 6. S-23-05 Tidal Wave Auto Spa at 245 N. DuPont Highway DAC Report of February 8, 2023 Page 5 trees proposed and a variety of other shrubs and ornamental plants. They have provided four (4) different Shade Tree types including Red Maple, Willow and Red Oak, and Kentucky Coffee Trees. These Trees are shown largely around the perimeter of the Site, as well as along the perimeter of the stormwater pond. The Plan further notes a variety of ornamental trees, deciduous shrubs, and evergreen shrubs. These are all shown largely around the perimeter of the Site. Arterial Street Buffer Requirements The Zoning Ordinance, Article 5 Section 7.3 requires that where a nonresidential zoned property fronts on a principal arterial street, a landscape buffer shall be required in addition to normal landscaping of the street right-of-way. Article 5, Section 7.31 further addresses the landscaping requirements of this buffer by noting that, at the time of development of the property, the arterial street buffer shall be planted with a variety of trees, shrubs and ground cover. The landscape design and planting plan for these arterial street buffers shall be subject to the approval of the planning commission as an integral part of the site development plan. The Site Plan submitted notes on the Landscape Plan (Plan Sheet C-701) that a 30-foot Arterial Street Buffer shows is to be implemented. This area appears to contain four (4) Red Oak shade trees, as well as a series of evergreen shrubs. Parking Lot Landscape Requirements The Zoning Ordinance Article 5 Section 7.23 requires that whenever a Parking Lot is located across the street from a residential use, it shall be screened from view of such land by a thick hedge located along a line drawn parallel to the street. Across White Oak Road to the south of the subject site is a series of properties zoned R-7 (One-Family Detached Dwelling Units) containing single family homes which are part of the Edge Hill neighborhood. The Applicant has shown that a row of evergreen shrubs is to be planted along the south property line (White Oak Road frontage). Interspersed with Red Maple Trees. The existing fence along this frontage appears to be removed with this redevelopment plan. The Site Layout does not show parking to be located along the south frontage of the site facing White Oak Road. Instead, the Plans show a drive aisle running along the White Oak Road frontage of the Site, accessing parking spaces for the Vacuum Stations immediately to the north of the drive aisle. These vehicle parking spaces face north, away from the houses across White Oak Road to the south. VIII. CITY AND STATE CODE REQUIREMENTS: The subject proposal has been reviewed for Code compliance, plan conformity, and completeness in accordance with this agency’s authority and area of expertise. The following items have been identified as elements which need to be addressed by the applicant: 1) Bicycle Parking is required to be provided at a rate of one (1) space for every twenty (20) vehicle parking spaces. The Plans must show where these facilities are to be located and must provide details as to the method thereof. 92

Paj 93

Item 6. S-23-05 Tidal Wave Auto Spa at 245 N. DuPont Highway DAC Report of February 8, 2023 Page 6 2) The Site currently consists of two (2) separate parcels. Ensure that all information provided regarding current conditions reflects this. 3) A separate Record Plan Sheet will need to be provided that addresses the proposed Lot Consolidation and any other Easements or other such features requiring recordation with the Kent County Recorder of Deeds. 4) For ease of reference, assign each of the existing Lots a common reference (“A” and “B”). 5) Clarify the Lot specifications. The Cover Sheet under “General Notes” does not provide information specific to either of the Lots. As such, there is a note on the “Min. Lot Area” being 2.04 +/- acres (88,718 SF), and then another note stating “Acreage of Proposed Disturbance: 2.15 acres +/-.” 6) Clarify the Elevation Drawings. Not all materials are identified. No information is provided on what appears to be the glass/ windows, especially those which appear to comprise the bulk of the west façade facing North DuPont Highway. This feature is identified with “T2” on the Drawing, but “T2” is not provided in the Materials Legend. Identify this material, clarify the color, and verify that these are to be windows. Also clarify as to how opaque or not this is to be, as this would expose the internal workings of the Car Wash. Similarly, what appears to be windows under the gable on the east façade is identified as “G3,” but there is no “G3” in the Legend. Lastly, the Legend notes materials “GL-1” and “GL-2,” but these do not appear to be shown on the Elevation Drawings. Clarify too the Building Materials and Colors and ensure that the information is consistent throughout. Sheet G100 of the Elevation Drawings shows Building Surface identified as “PT-1” being of a dark gray on the Elevation Drawing itself, but the Materials Legend shows this as being a light tan color “Quinoa.” 7) Clarify the Discrepancy between the Elevation Drawings submitted depicting one Canopy structure for 22 vacuum stations (11 on each side), as no such Canopy is shown on the Site Plan. The site Plan depicts 1 double-sided Canopy structure for 24 stations (12 on each side) with an enclosed space to the west end for equipment. There is also one Canopy structure to the north for 10 total Vacuum Stations. 8) All dumpster enclosures must be constructed of durable materials that will withstand the normal wear expected during trash removal. If the dumpster is within view of a public right of way it the appearance of the dumpster enclosure should complement the architecture of the principal building on the lot (Zoning Ordinance, Article 5, Section 6). Please clarify the construction details of the dumpster enclosure. 9) Since there is the presence of a dumpster enclosure on the plans it is under our assumption that the trash collection will be private. Please verify this with a note on the plans. 10) City of Dover Zoning Ordinance, Article 6, Section 3 requires curb height to be six inches in all permanent parking areas. Please clarify the height of the curbing shown on the plans. 93

Paj 94

Item 6. S-23-05 Tidal Wave Auto Spa at 245 N. DuPont Highway DAC Report of February 8, 2023 Page 7 11) Provide details on the Vacuum stations, noting the scale and location of the units. This should be done to convey that the Vehicle Parking Spaces do not impede the minimum 9’ x 18’ required for a vehicle parking space. 12) The tree density required is 1 tree per 3,000 SF of development area or fraction thereof (Zoning Ordinance, Article 5 Section 16.62). The development area of the Site appears to be incorrectly noted as 2.08 +/- acres, which is believed to only reference one of the two parcels. The site overall appears to be a combined 2.15 +/- acres. Confirm the area of Site overall (including both parcels) and provide their area in both acreage as well as square footage to confirm the tree planting calculations. 13) Cover Sheet (C-101): a. General Notes i. Note all of the Bulk Standards for the C-4 (Highway Commercial Zone) as found in Article 4, Section 4.15 of the Zoning Ordinance. Specify if the Bulk Standards noted are for the existing conditions, existing conditions per Lot, or proposed. It is noted that the side yard setback Provided of 244.3 feet appears to not account for the Canopies (roofed areas) over the Vacuum Stations. Adjust the Side Yard Setback figure accordingly. ii. Note the Lot Area of each existing Parcel, as well as the Area of the Subject Site Overall. Provide both in acreage and square footage. iii. Clarify the “Acreage of Proposed Disturbance, as this figure is greater than the actual Lot Area provided. iv. Correct the Vehicle Parking Space Calculations. The minimum number of Vehicle Parking Spaces required is thirteen (13), not 12. v. Provide the Tree Planting Calculations, ensuring this is determined based on the Site overall. vi. Note the Bicycle Parking Requirements. vii. Clarify the Note Referencing “Open Space: N/A.” viii. Note the current Lot Coverage figures. ix. Provide the Dumpster calculations, as well as identifying the method of Trash collection. 14) Site Plan (C-301): a. Clearly mark pedestrian crossing points. b. Show where any Vacuum equipment is to be located, ensuring that such equipment does not conflict with the required minimum vehicle parking area of 9’x 18’. c. Include a note that no tree planting shall be closer than 10 feet from any utility lines. 15) Signs are subject to a separate Sign Permit Review and approval process in the City of Dover. 16) Any Erosion & Sediment Control Plans and Stormwater Management Plans granted approval by the Kent Conservation District must reflect the Site Plan layout and design conditionally approved by the Planning Commission and be in compliance with the Zoning Ordinance and 94

Paj 95

Item 6. S-23-05 Tidal Wave Auto Spa at 245 N. DuPont Highway DAC Report of February 8, 2023 Page 8 technical review requirements of other agencies. 17) The Final Plan set must include notes documenting any action taken by the Planning Commission on the requested waivers and must list any additional conditions of approval. IX. RECOMMENDATIONS SUGGESTED AS CONDITIONS OF APPROVAL TO MEET CODE OBJECTIVES: In accordance with the Zoning Ordinance, Article 10 §2.2, the Planning Commission in considering and acting upon Site Development Plans may prescribe appropriate conditions and safeguards so that the public health, safety, and welfare, the comfort and convenience of the public in general, and the residents of the immediate neighborhood in particular shall be taken into consideration. These safeguards may to the maximum extent possible further the expressed intent of the Zoning Ordinance and the accomplishment of several objectives in particular listed in subsections 2.21 to 2.28. 1) Sidewalks: Both sidewalks providing pedestrian access to the site from North DuPont Highway and White Oak Road facilitate pedestrian traffic into awkward, potentially dangerous vehicle-oriented infrastructure. The north sidewalk connection currently is shown to connect directly into the drive aisle where cars queue for the car Wash. This sidewalk does not provide access to the proposed building or other site features, but rather crosses the north drive aisle three (3) times before connecting to sidewalks connecting to the properties to the east. The Applicant should look to reorganize the layout to ensure that pedestrian crossings are minimized, and that they cross at the narrowest possible points and in a manner to ensure visibility is not impeded. Similarly, the south sidewalk connection off White Oak Road, connects onto the subject site at an awkward point where several vehicle pathways converge, and then offers no defined pathway further into the site. This southern sidewalk connection should be relocated to minimize interaction between pedestrians and vehicles. Both sidewalk connection should be laid out in a manner to convey pedestrians with as little interaction with vehicle traffic as possible. Sidewalk connections should also clearly identify connection point to the main building, parking spaces, and other such Site features. The Plans should also clearly mark these links by ensuring that pedestrian crossings are clearly marked at drive aisles. X. ADVISORY COMMENTS TO THE APPLICANT: 1) In the event that major changes and revisions to the Site Plan occur in the finalization of the Plan, contact the Planning Office. Examples include reorientation of the building, relocation of site components like stormwater management areas, and increases in floor area count. These changes may require resubmittal for review by the Development Advisory Committee, Planning Commission, or other agencies and commissions making recommendations regarding the plan. 2) If there are changes to the architecture, building footprint, layout or square footage of the 95

Paj 96

Item 6. S-23-05 Tidal Wave Auto Spa at 245 N. DuPont Highway DAC Report of February 8, 2023 Page 9 building contact the Planning Office. These changes may require review by the Planning Commission. 3) Other agencies and departments which participate in the Development Advisory Committee may provide additional comments related to their areas of expertise and code requirements. 4) Following Planning Commission approval of the Site Development Plan, the Plan must be revised to meet all conditions of approval from the Development Advisory Committee or as otherwise noted. This process involves submission of Check Prints in order to achieve Final Plan approval. 5) For building new construction, the requirements of the building code and the fire code must be complied with. Consult with the Chief Building Inspector and City of Dover Fire Marshal for these requirements. The resolution of these items may impact the site design including such items as building dimensions and height, building openings, and fire protection needs, etc. 6) The applicant/developer shall be aware that prior to any ground disturbing activities on the site the appropriate Site Plan approvals, Pre-Construction meetings, site inspections and permits are required. 7) Construction may have an effect on the adjacent property owners and visitors. Any work requiring the closing or rerouting of residents or visitors should be coordinated as to offer the least amount of inconvenience. 8) The applicant shall be aware that Plan approval does not represent a Sign Permit, nor does it convey permission to place any sign on the premises. Any proposed site or building identification sign may require a Sign Permit from the City of Dover prior to placement of any such sign in accordance with Zoning Ordinance Article 5 §4. 9) The applicant shall be aware that Plan approval does not represent a Building Permit and associated construction activity permits. A separate application process is required for issuance of a Building Permit from the City of Dover. 10) All businesses operating in the City of Dover are required to obtain a City of Dover Business Licenses from the Licensing and Permitting Division. If you have any questions or need to discuss any of the above comments, please call the above contact person and the Planning Department as soon as possible. 96

Paj 97

Item 6. CITY OF DOVER DEVELOPMENT ADVISORY COMMITTEE APPLICATION REVIEW COMMENTARY STAFF D.A.C. MEETING DATE: FEBRUARY 1, 2023 APPLICATION: Tidal Wave Auto Spa at 245 N. Dupont Highway FILE #: S-23-05 REVIEWING AGENCY: City of Dover Department of Public Works and Water & Wastewater CONTACT PERSON: Jason A. Lyon, P.E., Director of Water & Wastewater / Engineering Services CONTACT PHONE #: 302-736-7025 CONTACT PHONE #: jlyon@dover.de.us T HE S UBJECT P ROPOSAL HAS BEEN R EVIEWED FOR C ODE C OMPLIANCE , P LAN C ONFORMITY AND C OMPLETENESS IN A CCORDANCE WITH THIS A GENCY ’ S A UTHORITY AND A REA OF E XPERTISE . T HE F OLLOWING I TEMS HAVE BEEN I DENTIFIED AS E LEMENTS W HICH N EED TO BE A DDRESSED BY THE A PPLICANT : CITY AND STATE CODE REQUIREMENTS SANITATION 1. Every commercial customer shall provide such premises with a sufficient number of solid waste containers to provide adequate capacity for the solid waste placed out for collection without overloading the capacity of the containers. The City of Dover shall provide commercial customers with a maximum of two (2), 90-gallon trash containers and two (2), 90-gallong recycling containers. 2. Trash collection site shall be oriented for side-loading pick-up if customer is utilizing City of Dover sanitation services. 3. Any commercial customer requiring more containers, or larger containers, than provided above, must utilize private service. STORMWATER 1. Final site plan approval will not be granted until a copy of the approved Stormwater/Erosion and Sediment Control Plan from Kent Conservation District / DNREC is submitted to our office. 2. The size, length, slope, type and flow directions must be shown on all existing and proposed storm sewer lines. Rim and invert elevations must be labeled on all stormwater structures. 3. The stormwater infrastructure proposed for this project shall be privately maintained. STREETS 1. Final site plan approval will not be granted until a copy of the approved entrance plan, signed by DelDOT is submitted to our office. 2. The current City of Dover standard street section provides for a 3’ grass strip between the curb and sidewalk. This standard was administratively revised to meet ADA and FHA compliance with cross slope requirements and to prevent cars from scrapping at driveways. The revised standard utilizes a five feet (5’) wide public sidewalk with a five feet (5’) wide grass strip behind the curb. WATER 97

Paj 98

Item 6. Tidal Wave Auto Spa at 245 N. Dupont Highway File #: S-23-05 February 1, 2023 Page 2 of 4 1. All water utility components must meet the requirements of the Water Wastewater Handbook, effective date March 22, 2010. Please contact our office for more information. 2. The following notes must be added to the plans: a. Hydrant connections by the contractor are prohibited. This method may not be utilized during any phase of the project. b. Any existing water lines not to be utilized by the proposed facility must be properly abandoned at the mains in accordance with the City of Dover Department of Water & Wastewater specifications and requirements. c. The site contractor shall contact the City of Dover Department of Water & Wastewater Construction Manager at (302) 736- 7025 prior to the start of construction. A representative from the City of Dover Department of Water & Wastewater must observe and approve all City owned water and sanitary sewer interconnections and testing. All water taps must be performed by a City of Dover approved contractor. The proposed location for the water connection may need to be adjusted in the field due to conditions of the existing main. Possible conditions that would require tapping relocation include proximity to pipe joints, other taps, concrete encasements, conflict with other utilities, and the like. Test holes must be performed by the contractor to determine the best tapping location. The City of Dover will not be held responsible for field conditions requiring adjustment of the tapping location or for any work required by the contractor to make an appropriate and lawful connection. 3. The size, type, and location of all proposed and existing water lines and valves must be shown on the plan. 4. Water usage projections (peak demand or plumbing fixtures) must be submitted to our office to correctly determine the size of the domestic and irrigation (if applicable) water meter for the proposed building. These projections must be submitted prior to approval so the meter size can be placed on the final site plan. The proposed water meter must be installed in a pit per City of Dover requirements and manufacturer’s recommendations. Also, a dual check valve is required downstream of the meter. 5. The domestic service, fire main connection and valves must be clearly shown for each building. A valve must be installed at the tee to isolate combined fire and domestic water service to the building from the water loop. Typically, this valve is installed at the tee or an acceptable distance from the building. A valve must be provided on the domestic water service, which must be tapped off of the combined eight-inch (8”) fire/domestic service outside of the building. The domestic water tap and valve should be as close to the building as possible. Typically, the domestic tap and valve are located within five feet (5’) to ten feet (10’) of the building. A blow up detail of this layout is recommended. 6. Provide a construction detail for the proposed restraining system for the fire main located within the buildings. The Department of Public Works will test and inspect all fire mains to a blind flange located inside the buildings. The blind flange with tap is used for hydrostatic pressure testing (200 psi for two (2) hours) and dechlorination. The flange must be restrained in the direction of the pipe entering the facility. A pipe entering horizontally through a wall sleeve shall be restrained with rods through the wall. A pipe entering vertically through a slab shall be restrained through the floor to the ninety degree (90 ) bend and thrust block. All rods shall be a minimum of ¾” all thread. All pipes through walls and slabs must be Class 52 cement lined ductile iron pipe. Confirm particulars to meet this requirement with mechanical designer. 7. Water services shall be either type K copper or SDR-9. 8. On October 24, 2022, City of Dover Council approved the new Cross Connection Control Program. This program requires certain backflow prevention assemblies on water service connections to the city’s distribution system. This project will require a double check valve assembly to be installed downstream of the water meter in the building. 9. Please provide a detailed plan on the water circulation plan for the car wash. WASTEWATER 1. All wastewater utility components must meet the requirements of the Water Wastewater Handbook, effective date March 22, 2010. Please contact our office for more information. 2. The following notes must be added to the plans: a. Any existing sanitary sewer lines not to be utilized by the proposed facility must be properly abandoned at the mains in accordance with the City of Dover Department of Water & Wastewater specifications and requirements. b. Part II, Chapter 180, Article III, Section 180-10 of the Code of Kent County requires that “no person shall discharge or cause to be discharged any stormwater, surface water, uncontaminated groundwater, roof runoff, subsurface drainage, 98

Paj 99

Item 6. Tidal Wave Auto Spa at 245 N. Dupont Highway File #: S-23-05 February 1, 2023 Page 3 of 4 uncontaminated noncontact cooling water or unpolluted industrial process waters to any sanitary sewer”, this shall include condensate. Sec. 110-231 of the City of Dover Code defines storm sewer as “…any system used for conveying rain water, surface water, condensate, cooling water or similar liquid wastes, exclusive of sewage.” The contractor, developer, owner and designers shall ensure during construction that no illegal discharges to the sanitary sewer system are created with the site improvements. 3. The size, length, slope, type and flow directions must be shown on all existing and proposed sanitary sewer lines. Rim and invert elevations must be labeled on all sanitary structures. 4. Cleanouts must be installed on sanitary sewer laterals within five feet (5’) of the building, one foot (1’) outside of the right-of- way and at all bends. Any cleanout located within a traffic bearing location shall be installed with a heavy duty cast iron frame and cover to prevent damage to the cleanout and lateral. 5. Sizing (flow) calculations must be submitted for all sanitary sewer laterals (other than for single-family dwellings) showing that velocity and all other requirements are met. 6. The minimum size of all sanitary sewer laterals shall be six-inch (6”). 7. Sanitary sewer laterals shall be connected directly to the main, not manholes, unless impracticable, as determined by the Department of Water & Wastewater. 8. The proposed twenty-foot (20’) easement shall not have any structure within its boundary. 9. Please provide hydraulic calculations that the proposed force main relocation will not interfere with proper operations of the upstream pump station. 10. Please provide a plan to allow the force main flow to be diverted during the proposed re-alignment. 11. As the City of Dover is a contract user of the Kent County Regional Resource Recovery Facility, an approval of the effluent makeup will be required from Kent County prior to final approval. 12. Please make the sanitary sewer connection directly to the main, not to the manhole, as outlined in the Water / Wastewater Handbook. GENERAL 1. All existing utilities shall be adjusted to final grade in accordance with current City of Dover requirements and practices. This must be included as a note on the plan. 2. No trees may be planted within ten feet (10’) of utility infrastructure. 3. No structure may be installed within ten feet (10’) of utility infrastructure, please depict all underground utilities and structures on the utility plan sheet to confirm compliance. 4. The final site plan must be submitted in the following compatible digital formats: a. AutoCAD 2018 (.dwg format). b. Adobe Reader (.pdf format). RECOMMENDATIONS SUGGESTED AS CONDITIONS OF APPROVAL TO MEET CODE OBJECTIVES SANITATION / STORMWATER / STREETS / WATER / WASTEWATER / GENERAL 1. None. ADVISORY COMMENTS TO THE APPLICANT WATER 1. The City of Dover water system is available to this site. The developer is responsible for all costs associated with extending and providing service to the proposed development. 99

Paj 100

Item 6. Tidal Wave Auto Spa at 245 N. Dupont Highway File #: S-23-05 February 1, 2023 Page 4 of 4 2. Prior to plan approval, the water system plans must be submitted to the Division of Public Health, Office of Drinking Water for review and approval. The owner/developer will be responsible for providing all completed forms and plan sets to the City of Dover as required for submission to the Office of Drinking Water. Plans will not be submitted to the Office of Drinking Water until review has been completed by our office. 3. Hydrant flow testing is currently only performed during the spring and fall. The applicant must call the Department of Water & Wastewater directly to schedule these tests. This applies to both existing hydrants as well as those proposed for the site. 4. Water impact fees may be required to be paid prior to Certificate of Occupancy for this project. WASTEWATER 1. The City of Dover sanitary sewer system is available to this site. The developer is responsible for all costs associated with extending and providing service and capacity to the proposed development. 2. Prior to plan approval, it may be required to submit the sanitary sewer system plans to the DNREC, Division of Water Resources, Surface Water Discharges Section for review and approval. The owner/developer is responsible for providing all application fees, completed forms and plan sets directly to DNREC. 3. Wastewater impact fees may be required to be paid prior to Certificate of Occupancy for this project. GENERAL 1. The applicant is advised that depending upon the size of the existing water service and sanitary sewer lateral to be abandoned, flowable fill may be required. 2. Construction plans will not be reviewed by our office unless all previous comments have been clearly addressed within the plan set and accordingly identified within an itemized response letter and with the Water/Wastewater Initial Plan Submission Checklist, which can be obtained from the following website: https://imageserv9.team- logic.com/mediaLibrary/198/WaterWastewaterHandbookFinal_1.pdf, page 88. SANITATION / STORMWATER / STREETS 1. None I F Y OU H AVE A NY Q UESTIONS OR N EED TO D ISCUSS ANY OF THE A BOVE C OMMENTS , P LEASE C ALL THE A BOVE C ONTACT P ERSON AND THE P LANNING D EPARTMENT AS S OON AS P OSSIBLE . 100

Paj 101

Item 6. CITY OF DOVER ELECTRIC DEVELOPMENT ADVISORY COMMITTEE APPLICATION REVIEW COMMENTARY STAFF D.A.C. MEETING DATE: FEB 1, 2023 APPLICATION: Tidal Wave Auto Spa at 245 N. Dupont Highway FILE #: S-23-05 REVIEWING AGENCY: City of Dover Electric Department CONTACT PERSON: Shawn Burgett, Engineering Services & System Operations Superintendent CONTACT PHONE #: 302-674-7568 CONTACT EMAIL #: sburgett@dover.de.us T HE S UBJECT P ROPOSAL HAS BEEN R EVIEWED FOR C ODE C OMPLIANCE , P LAN C ONFORMITY AND C OMPLETENESS IN A CCORDANCE WITH THIS A GENCY ’ S A UTHORITY AND A REA OF E XPERTISE . T HE F OLLOWING I TEMS HAVE BEEN I DENTIFIED AS E LEMENTS W HICH N EED TO BE A DDRESSED BY THE A PPLICANT : CITY AND STATE CODE REQUIREMENTS ELECTRIC 1. The roadway and curbing must be in. 2. The right-of-way must be within 6" of final grade. 3. The property corners must be staked. 4. Owner is responsible for locating all existing underground electric, communications and water facilities. 5. Owner is responsible for installing all conduits and equipment pads per the City of Dover Engineering Department specifications. 6. Owner is responsible for site and/or street lighting. 7. Meter locations will be determined by City of Dover Engineering Department. 8. Load sheets and AutoCAD compatible DXF or DWG diskettes of site plans, including driveways, are required prior to receiving approved electrical construction drawings. 9. Any relocation of existing electrical equipment will be engineered by the City of Dover Electric Department. Developer may be required to perform a quantity of the relocation. Any work performed by the City of Dover will be at the owner’s expense. 10. Prior to construction, owner is responsible for granting an easement to the City of Dover Electric Department. Easement forms will be furnished and prepared by the City of Dover Electric Engineering Department. 11. Fees will be assessed upon final site plans. The owner will be responsible for fees assessed prior to construction. Owner is required to sign off plans prepared by the Electric Department. 12. Must maintain 10' clearance around all electrical equipment, unless pre-approved by the City of Dover Electric Engineering Department. 101

Paj 102

Item 6. Tidal Wave Auto Spa at 245 N. Dupont Highway File #: S-23-05 Feb 1, 2023 Page 2 of 2 13. Prior to the completion of any/all designs and estimates, the owner is responsible for providing the Electric Engineering Department with a physical address of the property. 14. All Engineering and design for Dover Electric will be engineered upon final approved plans. All Engineering work will be furnished by the City’s Electric Engineering Department. RECOMMENDATIONS SUGGESTED AS CONDITIONS OF APPROVAL TO MEET CODE OBJECTIVES ELECTRIC 1. Owner must give the City of Dover Electric Department three (3) months’ notice prior to construction. Owner is responsible for following the requirements outlined in the City of Dover’s Electric Service Handbook. The handbook is now available on the website at the following link: https://evogov.s3.amazonaws.com/media/27/media/13108.pdf. ADVISORY COMMENTS TO THE APPLICANT ELECTRIC 1. Provide load sheets if the new load requirements will change as soon as possible to verify proper sizing of transformers and creation of primary fee estimates. Current load sheets can be found at the following link: https://www.cityofdover.com/media/Electric%20Department/COD%20Electric%20Load%20Sheet.pdf. I F Y OU H AVE A NY Q UESTIONS OR N EED TO D ISCUSS ANY OF THE A BOVE C OMMENTS , P LEASE C ALL THE A BOVE C ONTACT P ERSON AND THE P LANNING D EPARTMENT AS S OON AS P OSSIBLE . 102

Paj 103

C F S-23-05 Item 6. I I T R CITY OF DOVER Y E DEVELOPMENT ADVISORY COMMITTEE O M F A APPLICATION REVIEW COMMENTARY R D.A.C. MEETING DATE: 02/01/23 D S O H V A E L R APPLICATION: Tidal Wave Auto Spa at 245 N DuPont Hwy FILE #: S-23-05 REVIEWING AGENCY: City of Dover, Office of the Fire Marshal CONTACT PERSON: Jason Osika, Fire Marshal PHONE #: (302) 736-4457 THE SUBJECT PROPOSAL HAS BEEN REVIEWED FOR CODE COMPLIANCE, PLAN CONFORMITY, AND COMPLETENESS IN ACCORDANCE WITH THIS AGENCY’S AUTHORITY AND AREA OF EXPERTISE. THE FOLLOWING ITEMS HAVE BEEN IDENTIFIED AS ELEMENTS WHICH NEED TO BE ADDRESS BY THE APPLICANT: CITY AND STATE CODE REQUIREMENTS: 1. Proposed occupancy classification is business. 2. Building Access shall be no further than 50 feet from a primary entrance Where buildings are provided with an automatic sprinkler system installed in accordance with NFPA 13, access shall be no further than 100 feet from the primary entrance. (2021 Delaware State Fire Prevention Regulations, 705, Chapter 5, 3.4) 3. Parking shall be prohibited in front of the primary entrance for a width of not less than 1.5 times the width of the door(s) or for 10 feet, whichever is greater. (2021 Delaware State Fire Prevention Regulations, 705, Chapter 5, 6.3.2) 4. Perimeter access shall be 30% (15% if sprinklered) and clearly shown on the plans. Perimeter Access minimum width shall be10 feet for one-story buildings and 15 feet for buildings of two or more stories, measured from the face of the building at grade with a maximum slope of ten percent (10%). Plantings and utility services (includes condenser units, transformers, etc.) shall be permitted within the perimeter access, and shall not interfere with emergency services fire ground operations. If a physical barrier (fence, pond, steep slope, etc) prevents access, that portion of the building perimeter shall not be included in the calculation of Percent of Perimeter Access. (2021 Delaware State Fire Prevention Regulations, 705, Chapter 5, 3.5) Where parking is located between the building and perimeter access area, parking shall not be located closer than 10 feet to the exterior wall for one-story buildings and 15 feet to the exterior wall for building of two or more stories. 103

Paj 104

Item 6. 5. Any dead-end road more than 300 feet in length shall be provided with a turnaround or cul-de-sac as outlined in the 2021 Delaware State Fire Prevention Regulations 705, chapter 5, 2.3. 6. Speed Reduction Devices must be approved, please see City of Dover Ordinance Chapter 98-10 in reference to this process. 7. Fire hydrants shall be installed per the requirements of City of Dover Public Utilities Water/Wastewater Handbook, NFPA requirements, and Delaware State Fire Prevention Regulations. City Ordinance Sec 46-9 (f). 5.1.1 Hydrant spacing as shown in the Fire Flow Tables shall be used as a general rule. Hydrants shall be located at the direction of the State Fire Marshal so as to minimize friction in fire hose. All hydrant spacing shall be located along available roads or at the direction of the State Fire Marshal. This measurement shall be calculated by way of accessible thoroughfare(s) from the building to be protected to the hydrant and may not necessarily be a radius. 5.1.3 Additional hydrants shall be provided when the State Fire Marshal deems it necessary based on the configuration of the site, building(s), exposures, construction, occupancy, and/or specific hazard(s). Fire Flow table 2, hydrant spacing shall be 800 feet on center for one and two family detached dwellings, other residential, rowhouses and townhouses, assembly, health care, business, education, storage, industrial, mercantile, and mini storage. (702, Chapter 6) 8. All fire hydrants shall be marked as prescribed within the appropriate section of this regulation and as illustrated by the appropriate figures of this regulation. All fire hydrants shall have minimum of four-inch (4") solid yellow demarcation lines to define specific areas, where fire hydrants are located along a curb line with permitted parking, the area between the fire hydrant and the street or fire lane shall be stenciled with four inch (4") demarcation lines and the words "NO PARKING", demarcation lines shall be measured from the center line of the fire hydrant and extend for a distance 15 feet on both sides. Where fire hydrants are located in parking lots or other areas susceptible to blockage by parked vehicles they shall be treated as follows: fire hydrants shall be protected in all directions for a distance of seven feet (7') with barriers or curbing, Minimum four-inch (4") diameter steel bollards filled with concrete and marked yellow shall be installed at the outermost corners of the fire hydrant demarcation area. The minimum height of the bollard shall be 36 inches above the finished grade of the adjacent surface, and the steamer connection of all fire hydrants shall be positioned so as to be facing the edge of the street, or traffic lane. (2021 Delaware State Fire Prevention Regulations, 705, Chapter 6, 2) The owner is responsible if the hydrant is private. 9. Hydrant barrels shall be provided with reflective material, such as paint, durable for highway/roadway markings or a reflective tape of a minimum of 2” in width around the barrel under the top flange, hydrant bonnets shall be color coded based on the following criteria: class AA 1500 GPM - painted light blue, class A 1,000 GPM -1499 GPM - painted green, class B 500 - 999 GPM - painted orange, class C 250 - 499 GPM - painted red, class D under 250 GPM - painted black. (2021 Delaware State Fire Prevention Regulations 703, Chapter 3. 4) The owner is responsible if the hydrant is private. 10. Hydrants are to be Darling Co. B-62-B Breakaway https://american-usa.com/products/valves-and- hydrants/fire-hydrants/5-1-4-american-darling-b-62-b-5 11. NFPA 72 compliant Fire Alarm System TBD per occupancy code requirements. 104

Paj 105

Item 6. Fire alarm in place of assembly. Fire alarm required. Any new occupancy or new portion of an occupancy determined to be a place of assembly by the fire marshal and is capable of receiving an occupant load of 75 persons or greater, shall be required to install a fire alarm in accordance with NFPA codes governing the installation of fire alarms and the National Electrical Code. Fire alarm system required. Any existing occupancy or portion of an existing occupancy determined to be a place of assembly by the fire marshal, and is undergoing renovations in excess of 50 percent of the assessed value of the building and is capable of receiving an occupant load 75 persons or greater or is being enlarged to receive an occupant load of 75 persons or greater, shall be required to install a complete fire alarm system in accordance with NFPA codes governing the installation of fire alarms and the National Electrical Code. Public mode audible requirements. To ensure that audible public mode signals are clearly heard by occupants of a structure, they shall have a sound level at least 15 decibels (dB) above the average ambient sound level or five decibels (dB) above the maximum sound level having a duration of at least 60 seconds, whichever is greater, measured five feet (1.5m) above the floor in the area required to be served by the system using the A-weighted scale dBA. In the event the stated requirement cannot be met a shunt trip relay/switches shall be the approved method of meeting the intent of this section of the Code. (City Code of Ordinances 46-171) 12. The installation of natural gas and LP gas meters, regulators, valves, and LP gas bottles shall be protected from impact damage by impact protection. Natural gas and LP gas meters, regulators, and valves located inside structures shall have impact protection, except when located in separate protected utility rooms. Dimensions of bollards. Bollards shall be a minimum of six-inch diameter filled with concrete. The bollard shall be set into the ground at a depth of at least 36 inches (three ft.) embedded in concrete at a minimum of 18 inches surrounding the bollard. The bollards must be a least 48 inches (four ft.) in height above the finish grade elevation. Any deviation of the stated requirements must be approved by the fire marshal and/or chief building inspector. The above dimensions shall serve as the requirement for installation; however, the fire marshal and/or chief building inspector shall have the authority to require more stringent dimensions to fit the needs of devices warranting impact protection. Color of bollards. Bollards should be of the following colors; yellow, amber or orange. All colors shall be of fluorescent or have a reflective coating. Any deviation of the stated requirements must be approved by the fire marshal and/chief building inspector. (City of Dover Code of Ordinances, 46-4) 13. Every house, building or structure used or intended for use as living quarters or as a place for conducting business, and having any wall facing or abutting any public or private street or alley, shall have displayed on that wall, in legible, easily read characters which are of contrasting color to the background, the proper street number for such house, building, or structure in accordance with the following: One-family and two-family residential structures, height, the number shall measure a minimum of four inches in height, location, the number shall be placed on the house above or to the left or right of the front entrance, color, the number shall be contrasting to the background color, Arabic numerals, all numbers shall be Arabic numerals. 105

Paj 106

Item 6. Multiple-family dwellings, measurements, the number shall measure a minimum of six inches when identifying individual apartments with exterior doors, and 12 inches when identifying buildings with apartment complexes where there are two or more buildings not assigned street addresses. Individual buildings with street addresses shall have numbers measuring six inches, location, numbers shall be placed either in the center of the building or on the street end of the building so as to be visible from either the public or private street or from the parking lot, color, numbers shall be contrasting to the background color, Arabic numerals, all numbers used shall be Arabic numerals. Commercial, industrial and office buildings, height, the numbers shall measure a minimum of 12 inches in height, location generally, numbers shall be placed either in the center of the building or on the street end of the building so as to be visible from either the public or private street or from the parking lot, property line or driveway, should the building be located far enough from a public or private road so that the numbers are not clearly visible from the street, then the street address shall also be posted on the property at or near the property line or driveway to said building, color; each building, numbers shall be contrasting to the background color and shall be placed on each building in the complex, Arabic numerals, all numbers used shall be Arabic numerals, Shopping centers. Shopping centers consisting of two or more stores shall have a tenant or suite number affixed to the front of the tenant space and on the outside of the rear door which corresponds with that tenant space. Numbers shall measure six inches in height. (City of Dover Code of Ordinances, 98-344) 14. TBD A lock box (Knox) containing any and all means necessary for fire department access shall be provided at the following occupancies: any occupancy that contains a fire alarm signaling system that is monitored off-site, or any occupancy that contains an automatic sprinkler system. (2021 Delaware State Fire Prevention Regulations 705, Chapter 5, 2.4) Secured key systems. When required; exemption. A secured key system shall be required for any new or existing building where a fire alarm or sprinkler system is being installed. It shall be the responsibility of the owner or occupant to keep a set of keys in the secured key box that are current to the locks of the protected occupancy. Buildings with 24-hour staffing or guard service shall be exempt from this subsection. Location. The secured key system shall be located as close to the main entrance as possible. Should the building design not allow the secured key system to be located by the main entrance, the fire marshal and fire chief shall come to an agreement as to an alternate location for the key box. A secured key system, once installed, shall not be obstructed from view or obstructed by any means that would delay the fire department access to the box. Required keys. Keys to be secured in the key box shall include keys to all points of ingress or egress, whether on the interior or exterior of the building, and keys to locked mechanical rooms, electrical rooms, elevator rooms, fire alarm and sprinkler controls and any area protected by automatic fire detection. Keys to individual residential apartment units are not required. Ordering responsibility. It shall be the responsibility of the general contractor to order the key box for new buildings. It shall be the responsibility of the owner or tenant to order the key box for existing buildings. 106

Paj 107

Item 6. Installation before testing. No acceptance test for sprinklers or fire alarms shall be conducted before the installation of a key box. (City Code of Ordinances 46-127) Knox Box to be mounted 6 feet above ground level 15. All required means of egress shall have an exit discharge consisting of a non-slip surface and leading to and terminating at a public way. NFPA 101 16. Project to be completed per approved Site Plan. 17. Full building and fire plan review is required. 18. Separate building permits/plans submission will be required for each building and/or tenant fit out. If the permit submission is for a “shell” a Certificate of Occupancy will not be issued. Separate plans and permits submissions will be required for each “tenant fit out” at which time a Certificate of Occupancy will be issued upon compliance/completion of each “tenant fit out”. Each “shell” will require a fire permit for sprinkler and fire alarm if applicable. Those systems (for the “shell”) must be accepted into service prior to any “tenant fit out” fire permits being issued. 19. Construction or renovations cannot be started until building plans are approved. 20. Fire alarm systems, fire suppression systems, hoods, exhaust ducts, and hood suppression systems require a fire permit from the Fire Marshal’s Office. This work cannot be started until the permit is approved. 21. Building cannot be occupied by the public until a Certificate of Occupancy is obtained. 22. The following is City Ordinance, Appendix B-Zoning, Article 8 Enforcement and Penalties: Section 1. - Building permits. No building or structure in any district shall be erected or structurally altered without a building permit duly issued upon application to the building inspector. No building permit shall be issued unless the proposed construction or use is in full conformity with all the provisions of this ordinance. Any building permit issued in violation of the provisions of this ordinance shall be null and void and of no effect, without the necessity for any proceedings for revocations or nullification thereof, and any work undertaken or use established pursuant to any such permit shall be unlawful (see section 4 for penalties). 1.1 No building permit shall be issued for the construction or alteration of any building upon a lot without frontage upon, or legal permanent access to, a public street improved to the satisfaction of the planning commission, or without access to a public sewer. 1.2 No building permit shall be issued for any building where the site development plan of such building is subject to approval by the planning commission, except upon approval of such plans approved by the said commission. 1.21 No building permit shall be issued for any building in a subdivision unless the subdivision plot has been approved by the planning commission. 107

Paj 108

Item 6. 1.3 No building permit shall be issued for a building to be used for any conditional use in any zone where such use is allowed only with approval of the planning commission, unless and until such approval has been duly granted by the said commission. (Ord. of 7-12-1993, § 3) ADDITIONAL / SPECIFIC REQUIREMENTS TO OBTAIN APPROVAL: 1. Need to discuss current hydrant locations and if they ae adequate for this building. 2. Need to confirm proper turning radius for emergency apparatus 3. Ensure that e demo permit is obtained prior to any demolition APPLICABLE CODES LISTED BELOW (NOT LIMITED TO): 2021 NFPA 1 Fire Code (NFPA; National Fire Protection Association) 2021 NFPA 101 Life Safety Code (NFPA; National Fire Protection Association) 2019 NFPA 72 National Fire Alarm and Signaling Code (NFPA; National Fire Protection Association) 2019 NFPA 13 Installation of Sprinkler Systems (NFPA; National Fire Protection Association) 2009 IBC (International Building Code) Latest editions of all other NFPA Codes as defined by the Delaware State Fire Prevention Regulations 2021 Delaware State Fire Prevention Regulations City of Dover Code of Ordinances *If you have any questions or need to discuss any of the above comments, please call the above contact person listed. 108

Paj 109

Item 6. CITY OF DOVER D E DEVELOPMENT ADVISORY COMMITTEE L APPLICATION REVIEW COMMENTARY D O T =============================================================== APPLICATION: Tidal Wave Auto Spa at 245 N. Dupont Highway FILE#: S-23-05 REVIEWING AGENCY: DelDOT CONTACT PERSON: Joshua Johnson PHONE#: 302-760-2141 =============================================================== THE SUBJECT PROPOSAL HAS BEEN REVIEWED FOR CODE COMPLIANCE, PLAN CONFORMITY AND COMPLETENESS IN ACCORDANCE WITH THIS AGENCY'S AUTHORITY AND AREA OF EXPERTISE. THE FOLLOWING ITEMS HAVE BEEN IDENTIFIED AS ELEMENTS WHICH NEED TO BE ADDRESSED BY THE APPLICANT: CITY & STATE CODE REQUIREMENTS: No person, firm, corporation or the like shall construct, open, reconstruct, maintain, modify or use any crossing or entrance onto a state-maintained highway, street or road, including any drainage modifications leading into or carried by the highway drainage system, without first having complied with standards and regulations adopted by the Department and having obtained a permit issued by the Department. Please contact the Delaware Department of Transportation - Development Coordination section to begin permit process. RECOMMENDATIONS SUGGESTED AS CONDITIONS OF APPROVAL TO MEET CODE OBJECTIVES: ADVISORY COMMENTS TO THE APPLICANT: 1. DelDOT held a coordination meeting with the applicants on December 15, 2022. DelDOT anticipates this project will follow the standard Record Plan/Entrance Plan process. 109

Paj 110

KENT CONSERVATION DISTRICT Item 6. 1679 SOUTH DUPONT HIGHWAY • DOVER, DELAWARE 19901• (302) 608-5370 • WWW.KENTCD.ORG CITY OF DOVER DEVELOPMENT ADVISORY COMMITTEE APPLICATION REVIEW COMMENTARY FEBRUARY 2023 APPLICATION: Tidal Wave Auto Spa at 245 N Dupont Highway FILE #: S-23-05 REVIEWING AGENCY: Kent Conservation District CONTACT PERSON: Kate Owens PHONE: (302) 608 – 5370 EMAIL: stormwater@kentcd.org THE SUBJECT PROPOSAL HAS BEEN REVIEWED FOR CODE COMPLIANCE, PLAN CONFORMITY AND COMPLETENESS IN ACCORDANCE WITH THIS AGENCY’S AUTHORITY AND AREA OF EXPERTISE. THE FOLLOWING ITEMS HAVE BEEN IDENTIFIED AS ELEMENTS WHICH NEED TO BE ADDRESSED BY THE APPLICANT: Source: 2019 Delaware Sediment and Stormwater Regulations CITY AND STATE CODE REQUIREMENTS: 1. A detailed sediment and stormwater management plan must be reviewed and approved by the District prior to any land disturbing activity (i.e. clearing, grubbing, filling, grading, etc.) taking place. The review fee and a completed application are due at the time of plan submittal to the District’s office. 2. A pre-application meeting is required. 3. The following notes must appear on the record plan: a. The Kent Conservation District reserves the right to enter private property for purposes of periodic site inspection. b. The Kent Conservation District reserves the right to add, modify, or delete any erosion or sediment control measure, as it deems necessary. c. A clear statement of defined maintenance responsibility for stormwater management facilities must be provided on the Record Plan. ADVISORY COMMENTS TO THE APPLICANT: 1. Proposed facility must account for drainage areas managed by the existing dry pond facility and be designed according to the 2019 DSSR. 2. There is more than one existing stormwater facilities near the site that may be impacted. Site plan is to show all existing stormwater facilities on adjacent parcels. 3. A letter of no objection to recordation will be provided once the detailed Sediment and Stormwater Management Plan has been approved. 110

Paj 111

Item 6. GENERAL NOTES THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTEN TM 1. TAX MAP PARCEL NO.: 2-05-068.18-01-12.00 AND 2-05-068.18-01-13.00 2. OWNER OF RECORD: SITE CIVIL AND CONSULTING ENGINEERING TWAS PROPERTIES LLC 115 E MAIN ST. THOMASTON, GA 10286 LAND SURVEYING "E PARCEL NO. 2-05-06818-01-57 3. DEVELOPER/APPLICANT: °2 6'54 AUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES NEW POTATO CREEK HOLDING, LLC N69 9.50' PROGRAM MANAGEMENT 2 W E NAD83 NAD83 S C/O PJ LAND DEVELOPMENT, LLC 71 CAROLYN BOULEVARD W FARMINGDALE, NY 11735 LANDSCAPE ARCHITECTURE CONTACT: MIKE MCGRATH PHONE: 631-449-3791 30a 30b SUSTAINABLE DESIGN 4. ENGINEER: BOHLER 18958 COASTAL HIGHWAY, SUITE D N69 REHOBOTH BEACH, DE 19971 PERMITTING SERVICES °26' © BOHLER NA 50.8 54"E N6 D8 CONTACT: JUSTIN WITTERS, E.I.T. E 3 NA D8 8' 9°26 PHONE: 302-644-1155 251.87' S LOD 3 '5 17 30a 30b LOD LOD LOD 29.5 4"E LOD LOD TRANSPORTATION SERVICES LOD LOD 0' N49°22'38"E LOD LOD LOD LOD LOD LOD LOD 5. ZONING: LOD LOD LOD LOD EXIST. PARKING TO REMAIN (EMPLOYEE A. EXISTING: C-4 (HIGHWAY COMMERCIAL) 1 B. PROPOSED: C-4 (HIGHWAY COMMERCIAL) QR PARKING) LIMIT OF AREA TO 6. DATUM: BE MULCHED 10' REAR YARD SETBACK 28 A. HORIZONTAL DATUM IS NAD 83 AND BASED ON DB: 7129, PG. 159. SITE LOCATION MAP 29 30a 30b B. VERTICAL ELEVATIONS ARE BASED ON NAVD88. (N.T.S) LOD SOURCE: Google Imagery 2022 5 LOD 7. THE PROPERTY LINES AND TOPOGRAPHY SHOWN HEREON AREA TO BE SODDED 26 ARE BASED ON AN ALTA/NSPS LAND TITLE SURVEY BY RIDGE IGC 29 29 1 CONTROL POINT ASSOCIATES, INC., DATED 12/13/22. REVISIONS QR 10 8. LAND USE: LOD LIMIT OF AREA TO DRAWN BY EKM A. EXISTING: COMMERCIAL (RETAIL) REV DATE COMMENT BE MULCHED 3 3 1 CHECKED BY AR AR QR B. PROPOSED: COMMERCIAL (CAR WASH) LIMIT OF AREA TO 9. AREA REGULATIONS: SEE BULK REQUIREMENTS TABLE. BE MULCHED AREA TO BE SODDED LOD LOD 10. PARKING RATIONALE: 268.03' 30 A. REQUIRED PARKING: 1 PER 300SF OF FLOOR AREA 29 (3,690± SF) = 12 SPACES 4 PROP. CAN NOT WASH B. PROPOSED PARKING: 41 SPACES LOD QR LANE 28 LOD PROP. PAY N20 STATION 11. ACREAGE OF PROPOSED DISTURBANCE: 2.15± AC °32' 29 3 164 9"W 28 12. ALL ONSITE SOILS ARE Up - URBAN LAND R=1972.23' W RIDGE .93' Δ=005°53'16" 27 LOD LOD L=202.67' 1 26 AREA TO BE AC CHB=N19°58'05"W CHD=202.58' SODDED 1 PROP. SWM AREA CITY OF DOVER LANDSCAPE REQUIREMENTS 3 LOD W AR LOD SECTION 7. SUPPLEMENTARY REGULATIONS APPYLING TO ALL NON-RESIDENTIAL E1 ZONES: 5 QPH N/A 28 7.2 BUFFERING. 1 29 VISUAL AND SOUND SCREENING SHALL BE PROVIDED ON A NON-RESIDENTIAL USE W AC 26 WHEN ABUTTING A RESIDENTIAL USE. SCREENING SHALL CONSIST OF LANDSCAPING. LOD RO 27 LOD 7.3 BUFFERS ALONG ARTERIAL STREETS. 28 28 26 RIDGE WHERE A NONRESIDENTIAL ZONED PROPERTY FRONTS AN ARTERIAL STREET, A UT 27 V V LANDSCAPE BUFFER SHALL BE REQUIRED IN ADDITION TO NORMAL LANDSCAPING V V PARCEL NO. 2-05-06814-01-0100 15' SIDE YARD SETBACK V V OF THE STREET R.O.W. IN ALL NON-RESIDENTIAL ZONES. THESE BUFFER AREAS LOD RID SHALL BE A MINIMUM OF 30 FEET IN DEPTH, MEASURED FROM THE R.O.W. LINE, AND GE 10 LOD SHALL BE PLANTED WITH A VARIETY OF TREES, SHRUBS, AND GROUNDCOVER SO AS COMPLIES ARTICLE 5 TO CREATE A DISTINCTIVE AND CONSISTENT VISUAL CHARACTER OF THE ARTERIAL ALWAYS CALL 811 STREET. PROP. 146R COLD SUPPLEMENTARY It's fast. It's free. It's the law. U.S LOD TUNNEL BLDG. (±3,690 SF) REGULATIONS NOTE: BUFFERS ALONG ARTERIAL STREETS WERE REDUCED TO 20 FEET BY . LOD APPROVAL OF A WAIVER BY PLANNING COMMISSION WITH SITE PLAN S-16-02. SECTION 16. TREE PLANTING AND PRESERVATION: 16.62 TREE DENSITY. NOT APPROVED FOR CONSTRUCTION LOD ON EACH PROPERTY FOR WHICH A PLANTING PLAN IS REQUIRED, NEW TREES SHALL PROP. VACUUM PROP. TRASH ACK CANOPY ENCLOSURE BE PLANTED TO ATTAIN OR EXCEED A TREE DENSITY OF ONE (1) TREE PER 3,000 S.F. ETB OF LOT AREA. TREES TO MEET BUFFER REQUIREMENTS OR PARKING AREAS SHALL PROVIDED: ATE THIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY FMROW RD S AREA TO BE SODDED PARCEL NO. 2-05-06818-01-1300-0001 NOT BE COUNTED TOWARDS TREE DENSITY. 30 PROPOSED REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION FM TREES DOCUMENT UNLESS INDICATED OTHERWISE. LOD N/F LANDS OF TIM T YA LIMIT OF REQUIRED: ER SL 28 TWAS PROPERTIES LLC LOD TOTAL LOT AREA: 88,718 +/- SF (AFTER DEDICATION) . UL AREA TO BE D.B. 12280, PG. 250 PROJECT No.: DEA220053.00 RON UFF MULCHED DRAWN BY: JSW PRO 20' F V 88,718 S.F. / 3,000 S.F. = 30 TREES** P DSC V V V CHECKED BY: DMK 3A0PE B FM V V DATE: 1/5/23 LOD FM V 2 CAD I.D.: PRLM - 0 SL LOD LANDSCAPE SCHEDULE S40°40'55"E 29 12 30' L AN RID PROJECT: FM 28 G E SYM. KEY QTY. BOTANICAL NAME COMMON NAME CAL. CONT. SPACING LOCATION RIDGE LOD FM SHADE TREES 56. 04' 62 RCW SL SITE DEVELOPMENT 2 1/2-3" CAL. / PLAN A AR 10 ACER RUBRUM RED MAPLE B+B PER PLANS PER PLANS G 12-14' HT. 32 12 LOD LOD FM S50°41'05"W G FM IGC FOR V V R=5790.50' 5.46' PARCEL NO. 2-05-06818-01-1200 SL V V GD 10 GYMNOCLADUS KENTUCKY 2 1/2-3" CAL. / B+B PER PLANS PER PLANS 001°09'37" N/F LANDS OF G V V V DIOCUS COFFEETREE 12-14' HT. TIDAL WAVE L=117.27' G CHB=N16°12'55"W 3"W TWAS PROPERTIES LLC D.B. 12280, PG. 250 FM FM 22 1 28 2 LOD QPH 5 QUERCUS PHELLOS WILLOW OAK 2 1/2-3" CAL. / B+B PER PLANS PER PLANS AUTO SPA CHD=117.27' 5'0 PROP. TRIPLE VACUUM ISLAND TO BE MULCHED 12-14' HT. SL SL SL SL SL SL JDP AR AR LO SL RE ENCLOSU SL SL 5°4 D AREA TO BE SODDED 10 N1 FM FM FM FM FM FM 26 30a 2 1/2-3" CAL. / 30 FM FM FM FM FM FM GD QR 7 QUERCUS RUBRA RED OAK B+B PER PLANS PER PLANS FM FM AREA TO BE SODDED FM FM FM FM SL LOD 12-14' HT. 52 IGC PROPOSED LIMIT OF AREA TO SUBTOTAL: 32 LOD BE MULCHED DEVELOPMENT SL 245 N DUPONT HIGHWAY 30a 30b ORNAMENTAL TREES 30a 30b CITY OF DOVER 30' LANDSCAPE BUFFER LOD AMELANCHIER MULTI STEM 1-1 1/2" CAL. / KENT COUNTY, DE 19901 AC 2 SHADBLOW B+B PER PLANS PER PLANS LOD 27 29 CANADENSIS SERVICEBERRY 8-10' HT. PARCEL #: 2-05-068.18-01-12.00 28 AND 2-05-068.18-01-13.00 DECIDUOUS SHRUBS PROP. EXIT 20' FRONT YARD SETBACK SL WASH LIGHT TPF RCW 62 ROSA 'CAREFREE CAREFREE WONDER 24" HT. 3 GAL. PER PLANS PER PLANS TPF TPF WONDER' ROSE LOD TPF TPF LOD TPF TPF LOD LOD EVERGREEN SHRUBS 29 TPF TPF P.O.B. S39°18'55"E TPF LOD LOD LOD D.B. 7129, PG.159 EUONYMUS MANHATTAN TPF LOD C:\PROGRAMDATA\BOHLER\C3D2020\TEMP\ACPUBLISH_20716\UNSAVED DRAWING2----->LAYOUT: C-701 - LANDSCAPE PLAN N39°30'45"W 5.00' LOD SL LOD EKM 10 KIAUTSCHOVICUS SPREADING 24-30" HT. #5 CAN PER PLANS PER PLANS 32.46' LOD LOD S50°41'05"W TREE PROTECTION FENCE TO 216.11' 18958 COASTAL HWY, SUITE D S50°29'15"W 5.00' 'MANHATTAN' EUONYMUS BE PROVIDED WITH / IN FINAL ILEX GLABRA DWARF INKBERRY REHOBOTH BEACH, DE 19971 S50°29'15"W 111.62' ENGINEERING PLANS IGC 110 'COMPACTA' HOLLY 24-30" HT. #5 CAN PER PLANS PER PLANS Phone: (302) 644-1155 LOD JUNIPERUS DAVURICA Fax: (302) 703-3173 LOD SL LOD JDP 22 'PARSONI' PARSON JUNIPER 15-18" SPRD. #3 CAN PER PLANS PER PLANS BohlerEngineering.com LOD LOD LOD LOD LOD LOD LOD LOD SUBTOTAL: 142 E.R. McWILLIAMS NOTE: IF ANY DISCREPANCIES OCCUR BETWEEN THE AMOUNTS SHOWN IN THE PLAN AND THE PLANT LIST, THE PLAN WILL DICTATE. M . K U D.M. KUKLISH D K LOD CENSE LOD SL LI I L V 13. BULK REQUIREMENTS: ALLOWED/REQUIRED PROVIDED I S D A 19a 01/06/2023 H:\16\DE160018\Drawings\Images\Signature_Page_1 (2).jpg H A. MIN. LOT AREA N/A 88,718± SF (2.04± AC)* 20 No.14522 B LOD SL LOD B. MIN. BUILDING SETBACK REGISTERED PROFESSIONAL LANDSCAPE ENGINEER ARCHITECT DELAWARE DELAWARE LICENSE LICENSE No.No. S1-0000502 14522 FRONT SETBACK (US ROUTE 13) R P RO 30' 30' MARYLAND LICENSE No.36224 FRONT SETBACK (WHITE OAK ROAD) 30' 62.1' VIRGINIA LICENSE No. 0402045209 D EE ES E L1/5/23 R E IN SIDE SETBACK (EAST) 15' 244.3' F AWA S IO G REAR SETBACK (NORTH) 10' 57.2' NA L E N C. PARKING REQUIREMENTS 1 SPACE PER 300 S.F. OF GFA SHEET TITLE: (3,690 GFA/300) = 12 OR 41 (2 ADA SPACES) OR 1 PER EMPLOYEE. (INCLUDING 5 EMPLOYEE (3 EMPLOYEES) = 3 SPACES) WHICHEVER CALCULATION RESULTS IN THE HIGHEST AMOUNT OF PARKING. 12 REQUIRED LANDSCAPE D. MIN. PARKING SPACE DIMENSIONS 9' x 18', 8' x 18' (ADA) 9' x 18', 8' x 19' (ADA) PLAN WHITE OAK ROAD E. MIN. DRIVE AISLE WIDTH 10' (ONE WAY) 20' (TWO WAY) 18' MIN. (ONE WAY) 24' MIN. (TWO WAY) SHEET NUMBER: C-701 F. MAX. BUILDING HEIGHT 75' OR 6 STORIES 24.0'± (1 STORY) G. OPEN SPACE N/A N/A 20 10 5 0 20 H. MAX. BUILDING COVERAGE/TOTAL IMPERVIOUS 75% 58.3±% (51,723± SF) . COVERAGE (% OF LOT) Jan 06, 2023 1"= 20' *NOTE: ALL AREAS LISTED ARE TAKEN AFTER DELDOT DEDICATION IS ACCOUNTED FOR JC ORG. DATE - 1/5/23 111

Paj 112

Item 6. 1 2 3 4 5 6 7 8 9 10 11 12 15" HIGH FACE-LIT CHANNEL LETTERS EXTERIOR MATERIAL LEGEND 3 2.1 2 1 5 3 2.1 2 2 2.1 3 1 ON PAINTED RACEWAY 19.01 SQ. FT. 2 2.1 3 4 5 ARCHITECT SNOW/ ICE MELT REFER TO EXTERIOR SIGN PACKAGE SNOW/ ICE MELT G1 GUARD; SCREW DOWN BEING FILED SEPARATELY FOR MORE GUARD; SCREW DOWN MARK ST-1 BAR OR FENCE STYLE INFORMATION. BAR OR FENCE STYLE ITEM SPLITFACE BLOCK VENEER T/ RIDGE MFR ECHELON / OLD CASTLE 120' - 0" 15" HIGH FACE-LIT CHANNEL LETTERS ON FINISH TAN (OAK) PT 1 PT 1 PAINTED RACEWAY 19.01 SQ. FT. REFER STYLE SPLITFACE RF 1 TO EXTERIOR SIGN PACKAGE BEING FILED 33 Walt Whitman Road, Suite 300A NOTES 8"H X 16"L X 4" (NOMINAL) SEPARATELY FOR MORE INFORMATION. RF 1 RF 1 Huntington Station, NY 11746 T: 631-683-5588 F: 631-683-5591 B/ ROOF TRUSS www.sblm.com 114' - 0" RF 1 5H RF 1 5H MARK ST-2 A601 A601 ITEM CAST STONE WATERTABLE J MFR BORAL J PROJECT FINISH WHITE PT 1 PT 1 ST 2 PT 1 STYLE - NOTES 7 5/8" H X 5 5/8" D X 4'-0" L MT 1 MT 1 MT 1 MT 1 MT 1 MT 1 WITH 45 DEGREE BEVEL AND DRIP ST 3 ST 3 ST 3 ST 3 ST 3 ST 3 ST 2 ST 2 ST 2 ST 2 ST 2 ST 2 5'-0" MARK ST-3 T/ CONC @ ST 1 3'-8" ST 1 ST 1 3'-8" ST 1 ST 1 3'-8" ST 1 ITEM THIN-SET STONE VENEER TUNNEL CAST IRON DOWNSPOUT MFR CENTURION STONE 100' - 0" BOOT, FIELD PAINT COLOR FINISH GRAY, RUST, TAN OHC 04 03 OHB 06 05 AS SELECTED BY OWNER, TIDAL WAVE AUTO SPA B1A PT 2 PT 2 B1 G1 PT 2 PT 2 STYLE KENTUCKY LEDGESTONE TYPICAL ALL DOWNSPOUTS PARCEL ID #: 068.18-01-12.00 & 13.00 NOTES - 245 N DUPONT HIGHWAY 2H SIDE ELEVATION - ENTRY 6H SIDE ELEVATION - ENTRY 8H SIDE ELEVATION - ENTRY 10H SIDE ELEVATION - EXIT CITY OF DOVER KENT COUNTY, DE 19901 G100 3/16" = 1'-0" G100 3/16" = 1'-0" G100 3/16" = 1'-0" G100 3/16" = 1'-0" H H CLIENT MARK PT-1 A A.1 B B.1 C D D.1 E F G E.1 H D.1 I J B.1 K K L PJ LAND DEVELOPMENT, LLC ITEM EXTERIOR PAINT 71 CAROLYN BOULEVARD MFR SHERWIN WILLIAMS FARMINGDALE, NY 11735 20" HIGH FACE-LIT CHANNEL LETTERS ON RACEWAY. SNOW/ ICE MELT FINISH SW 9102 QUINOA 33.78 SQ. FT. REFER TO EXTERIOR SIGN PACKAGE BEING GUARD; SCREW DOWN STYLE ELASTOMERIC BAR OR FENCE STYLE T/ RIDGE FILED SEPARATELY FOR MORE INFORMATION. NOTES LOUVERS & MISC. METAL ITEMS ON EIFS PROVIDE 120' - 0" CUSTOM COLOR EIFS TO MATCH PT-1 RF 1 RF 1 MARK PT-2 B/ ROOF TRUSS ITEM EXTERIOR PAINT MFR SHERWIN WILLIAMS 114' - 0" FINISH SW 2735 ROCKWEED STYLE METAL NOTES ALL HM DOORS AND G FRAMES G CONSULTANT STRUCTURAL MT 1 MT 1 HART GAUGLER + ASSOCIATES 12801 N. CENTRAL EXPRESSWAY, SUITE 1400 MARK PT-3 ST 3 ST 3 DALLAS, TX 75243 ITEM EXTERIOR PAINT 972.239.5111 MFR - ST 2 ST 2 FINISH - M.E.P. STYLE STEEL T/ CONC @ ST 1 3'-8" 3'-8" ST 1 ACERTUS CONSULTING GROUP, LLC NOTES ALL EXPOSED TUNNEL 14817 WEST 95TH STREET STRUCTURAL STEEL, LENEXA, KS 66215 TRUSSES, COLUMNS 100' - 0" 913.322.5150 OHH PT 3 OHG PT 3 OHF T2 T2 PT 3 T2 PT 3 T2 PT 3 T2 PT 3 T2 T2 PT 3 T1 CIVIL MARK SF-1 2F FRONT ELEVATION WEIHE ENGINEERS, INC. 10505 N COLLEGE AVENUE ITEM STOREFRONT G100 3/16" = 1'-0" INDIANAPOLIS, INDIANA 46280 MFR KAWNEER 317.846.6611 F FINISH BRONZE F STYLE SMOOTH L K J I H G.1 G F 4'-10" HIGH CABINET SIGN. D.1 D C B.1 B A.1 A NOTES STOREFRONT FRAMES +/- 41 SQ. FT. REFER TO SNOW/ ICE MELT EXTERIOR SIGN PACKAGE SNOW/ ICE MELT GUARD; SCREW DOWN G3 GUARD; SCREW DOWN BEING FILED SEPARATELY T/ RIDGE BAR OR FENCE STYLE FOR MORE INFORMATION. BAR OR FENCE STYLE 120' - 0" MARK RF-1 ITEM METAL ROOF R-PANELS MFR BERRIDGE RF 1 RF 1 FINISH ROYAL BLUE STYLE PRE-FINISHED B/ ROOF TRUSS NOTES PRE-FINISHED METAL 114' - 0" ROOF & ACCESSORIES E MARK MT-1 E SEAL ITEM METAL ROOF L-PANEL MFR BERRIDGE MT 1 MT 1 FINISH ROYAL BLUE STYLE PRE-FINISHED, SMOOTH ST 3 ST 3 NOTES PRE-FINISHED METAL TRIM, SOFFIT & ACCESSORIES ST 2 ST 2 PERFORATED WHERE INDICATED T/ CONC @ ST 1 3'-8" 3'-8" 3'-8" 3'-8" ST 1 TUNNEL 100' - 0" MARK GL-1 T1 PT 3 T2 PT 3 T2 09A T2A PT 1 ST 2 ST 3 ST 1 CT CABINET SF3 PT 3 OHE OHD 09 01 SF1 ITEM INSULATED GLAZING MFR KAWNEER FINISH CLEAR 2D REAR ELEVATION STYLE SMOOTH G100 3/16" = 1'-0" NOTES STOREFRONT GLAZING L K J I H G F E D.1 D C B A D D PROJECT REVISIONS 2F 2F ISSUED: 01/06/2023 G100 G100 MARK GL-2 REVISED: ITEM INSULATED GLAZING # DATE DESCRIPTION MFR KAWNEER 1 - 01-06-23 COLOR ELEVATIONS FINISH SPANDREL STYLE SMOOTH NOTES STOREFRONT GLAZING 10H 2H NOTE: G100 G100 WASH ENTRY ALL GROUND AND ROOF-MOUNTED TUNNEL 102 MECHANICAL UNITS WILL BE 103 C C COMPLETELY SCREENED FROM VIEW FROM ADJACENT PROPERTIES AND RIGHTS OF WAY. 2 2.1 OPERATOR 101 MECHANICAL PROJECT INFORMATION RR ROOM 104 105 TIDAL WAVE AUTO SPA ADDRESS: 245 N DUPONT HIGHWAY 4 CITY OF DOVER KENT COUNTY, DE 19901 B B PROJ. NO: TWC023 DRAWN BY: PMO CHECKED BY: ERT EQUIPMENT ELECTRICAL A.1 SHEET SIZE: 30" x 42" ROOM ROOM 106 107 6H 8H G100 G100 SHEET TITLE & NUMBER PRIMARY BUILDING 2D 5 2D COLOR ELEVATIONS G100 G100 A 2A G100 PRIMARY BUILDING - FLOOR PLAN 3/16" = 1'-0" A G100 1 2 3 4 5 6 7 8 9 10 11 12 Copyright 2022 SBLM 112

Paj 113

Item 7. PROPOSED AMENDMENTS TO THE 2019 COMPREHENSIVE PLAN For Review and Recommendation by City of Dover Planning Commission February 21, 2021 MI-23-01 Comprehensive Plan Amendments 2023 Review of a series of Amendments to the 2019 Comprehensive Plan, as amended. The Amendments include consideration of the following as associated with Annexation Application AX-23-01 Lands of Calpine Holdings, LLC – Two Properties on White Oak Road: requests for amendment of Map 13-1: Potential Annexation Areas to revise the Annexation Plan category of two properties and requests for amendment of Map 13-2: Potential Land Uses for Annexation Areas to identify the Land Use Classification of two properties. A. Consideration of Amendments to Map 13-1: Potential Annexation Areas Plan Map - Request for two parcels located on the north side of White Oak Road and west of Bayside Drive to revise the Annexation Plan category from Area of Concern and unidentified area to Category 2: Priority Annexation Area on Map 13-1: Potential Annexation Areas Plan Map. a. Property Area: 144.83 acres +/-. Property Address: unaddressed parcel near White Oak Road. Property Owner: Calpine Holdings, LLC. Tax Parcel: LC- 00-058.00-02-49.00-000. b. Property Area: 104.06 acres +/-. Property Address: 3015 White Oak Road. Property Owner: Calpine Holdings, LLC. Tax Parcel: LC-00-058.00-02- 48.00-000. B. Consideration of Amendments to Map 13-2: Potential Land Use for Annexation Areas Map - Request for two parcels located on the north side of White Oak Road and west of Bayside Drive to identify the Land Use Classification as Public & Private Utilities on Map 13-2: Potential Land Use for Annexation Areas Map. a. Property Area: 144.83 acres +/-. Property Address: unaddressed parcel near White Oak Road. Property Owner: Calpine Holdings, LLC. Tax Parcel: LC- 00-058.00-02-49.00-000. b. Property Area: 104.06 acres +/-. Property Address: 3015 White Oak Road. Property Owner: Calpine Holdings, LLC. Tax Parcel: LC-00-058.00-02- 48.00-000. Ordinance Number: #2023-01 113

Paj 114

Item 7. City of Dover CITY OF DOVER Planning DEVELOPMENT ADVISORY COMMITTEE Office APPLICATION REVIEW COMMENTARY D.A.C. MEETING DATE: February 8, 2023 APPLICATION: Comprehensive Plan Amendments 2023: MI-23-01 A. Consideration of Amendments to Map 13-1: Potential Annexation Areas Plan Map and B. Consideration of Amendments to Map 13-2: Potential Land Use for Annexation Areas Map FILE#: MI-23-01A and B REVIEWING AGENCY: City of Dover Planning Office CONTACT PERSON: Dawn Melson-Williams, AICP PHONE#: 736-7196 I. PROCESS BACKGROUND: The 2019 Comprehensive Plan was recommended by Planning Commission and adopted by City Council on January 13, 2020 and certified that date as per letter of March 10, 2020 issued by Governor Carney. Since that time, the 2019 Comprehensive Plan was amended in 2021 following consideration of Application MI-21-01A, B, and C which specifically focused on a series of requests for changes to the Map 12-1: Land Development Plan. Additionally, as part of the 2021 Comprehensive Rezoning Project, there were additional amendments to Map 12-1: Land Development Plan Map and Table 12-1: Land Use and Zoning Matrix. As adopted, the 2019 Comprehensive Plan sets forth a process by which the Comprehensive Plan can be amended on an annual basis. Amendments to the Comprehensive Plan can be initiated by staff or requested by members of the public. The process to amend the Comprehensive Plan is detailed in the 2019 Comprehensive Plan, Chapter 15: Implementation, specifically on pages 15-10 thru 15-12 of the Plan. The Request requires submission of the following: a Comprehensive Plan Amendment Application, other appropriate application form and fee based on the request type, property information (drawing), an analysis of the surrounding land uses and zoning classifications, and a statement of how the Request is consistent with the goals of the Comprehensive Plan. For amendments to the Comprehensive Plan that involve rezoning of property, the requests are processed concurrently. Review of the Comprehensive Plan Amendment Requests begins with the PLUS Review Process. Next the Requests are reviewed through Development Advisory Committee Review as the next step in the Review Process leading to the Public Hearings and Review by the City of Dover Planning Commission and Dover City Council. Comprehensive Plan Amendments are adopted through adoption (approval) of an Ordinance. Submitted Requests for 2023 These Requests for Amendment of the 2019 Comprehensive Plan were submitted by the property owner as associated with the City of Dover’s annual opportunity to request 114

Paj 115

Item 7. MI-23-01A and B – Comprehensive Plan Amendments 2023: Amendments to Map 13-1 and Map 13-2 Lands of Calpine Holdings, LLC – Two Properties on White Oak Road DAC Report of February 8, 2023 Page 3 of 7 Comprehensive Plan Amendments (deadline of December 15, 2022 for review as 2023 Amendments). The property owner Calpine Holdings, LLC has made two requests for amendments to the Annexation Plan (Map 13-1 and Map 13-2) associated with two properties on White Oak Road. See the detailed description of the Requests in Report Section II below. Ordinance #2023-01 is proposed for adoption of these Comprehensive Plan Amendments 2023. In this Request, the associated application type is for annexation. A separate process will follow for consideration of the Annexation Application AX-23-01 Lands of Calpine Holdings, LLC – Two Properties on White Oak Road. Preliminary Land Use Services (PLUS) Review This process involves review of the proposed amendments through the PLUS (Preliminary Land Use Services) Review process. This Request (Amendment MI-23-01 A and B) was part of the Comprehensive Plan Amendments 2023 submitted by the City’s Planning Office to the Office of State Planning Coordination for PLUS Review. It was presented at the January 25, 2023 PLUS review meeting (PLUS #2023-01-09 City of Dover Comprehensive Plan Amendment – Calpine Holdings, LLC). The PLUS Review comments will be forthcoming on these Amendments to the Comprehensive Plan. II. REQUESTS FOR COMPREHENSIVE PLAN AMENDMENT: The proposed Comprehensive Plan Amendments are detailed below and represented in the Attachments. The Requests are an applicant initiated filing by property owner Calpine Holdings, LLC. MI-23-01 Comprehensive Plan Amendments 2023 Review of a series of Amendments to the 2019 Comprehensive Plan. The Amendments include consideration of the following as associated with Annexation Application AX-23-01 Lands of Calpine Holdings, LLC – Two Properties on White Oak Road: requests for amendment of Map 13-1: Potential Annexation Areas to revise the Annexation Plan category of two properties and requests for amendment of Map 13-2: Potential Land Uses for Annexation Areas to identify the Land Use Classification of two properties. A. Consideration of Amendments to Map 13-1: Potential Annexation Areas Plan Map - Request for two parcels located on the north side of White Oak Road and west of Bayside Drive to revise the Annexation Plan category from Area of Concern and unidentified area to Category 2: Priority Annexation Area on Map 13-1: Potential Annexation Areas Plan Map. a. Property Area: 144.83 acres +/-. Property Address: unaddressed parcel near White Oak Road. Property Owner: Calpine Holdings, LLC. Tax Parcel: LC-00-058.00-02- 49.00-000. • 2019 Comprehensive Plan, Map 13-1 – Annexation Plan Category: None • Proposed Comprehensive Plan Designation, Map 13-1 Annexation Plan Category: Category 2 – Priority Annexation Area 115

Paj 116

Item 7. MI-23-01A and B – Comprehensive Plan Amendments 2023: Amendments to Map 13-1 and Map 13-2 Lands of Calpine Holdings, LLC – Two Properties on White Oak Road DAC Report of February 8, 2023 Page 4 of 7 b. Property Area: 104.06 acres +/-. Property Address: 3015 White Oak Road. Property Owner: Calpine Holdings, LLC. Tax Parcel: LC-00-058.00-02-48.00-000. • 2019 Comprehensive Plan, Map 13-1 – Annexation Plan Category: Area of Concern • Proposed Comprehensive Plan Designation, Map 13-1 Annexation Plan Category: Category 2 – Priority Annexation Area B. Consideration of Amendments to Map 13-2: Potential Land Use for Annexation Areas Map - Request for two parcels located on the north side of White Oak Road and west of Bayside Drive to identify the Land Use Classification as Public & Private Utilities on Map 13-2: Potential Land Use for Annexation Areas Map. a. Property Area: 144.83 acres +/-. Property Address: unaddressed parcel near White Oak Road. Property Owner: Calpine Holdings, LLC. Tax Parcel: LC-00-058.00-02- 49.00-000. • 2019 Comprehensive Plan, Map 13-2 – Land Use Classification: None • Proposed Comprehensive Plan Designation, Map 13-2 Land Use Classification: Public & Private Utilities b. Property Area: 104.06 acres +/-. Property Address: 3015 White Oak Road. Property Owner: Calpine Holdings, LLC. Tax Parcel: LC-00-058.00-02-48.00-000. • 2019 Comprehensive Plan, Map 13-2 – Land Use Classification: None • Proposed Comprehensive Plan Designation, Map 13-2 Land Use Classification: Public & Private Utilities Thus, these Requests for Amendment of the 2019 Comprehensive Plan seek to amend Map 13-1 and Map 13-2. Applicant’s Submission: The following items were submitted by the applicant: property location information (maps), written analysis of surrounding land uses and zoning classifications, and a written statement on how the request is consistent with the goals of the Comprehensive Plan. Also submitted was a highlighted document of excerpts of the 2019 Comprehensive Plan (provided in packet). Map Exhibits: Planning Staff has provided copies of Map 13-1: Potential Annexation Areas and Map 13-2: Potential Land Use for Annexation Areas as adopted in the 2019 Comprehensive Plan. For each Comprehensive Plan Amendment Request, Staff has prepared Exhibit Maps showing the current and proposed Annexation Areas (excerpts of Map 13-1) and current and proposed Land Use Classifications (excerpts of Map 13-2). III. PROPERTY BACKGROUND The two subject properties consist of an unaddressed parcel (Property a, Parcel 49.00) located north of White Oak Road and the property addressed as 3015 White Oak Road (Property b, Parcel 48.00). These are located to the east of the incorporated limits of the City of Dover. They share a property boundary with the lands within the Garrison Oak Business and Technology 116

Paj 117

Item 7. MI-23-01A and B – Comprehensive Plan Amendments 2023: Amendments to Map 13-1 and Map 13-2 Lands of Calpine Holdings, LLC – Two Properties on White Oak Road DAC Report of February 8, 2023 Page 5 of 7 Center (previously known as Garrison Oak Technology Park). The northern subject parcel contains woodland areas while the southern parcel includes agricultural fields which have previously been under cultivation along White Oak Road. Contained on these properties are also wetland areas, a tax ditch network, a stream, and other drainage conveyances that cross the properties. The applicant has previously filed an application with Kent County for development of a solar panel array on 94.6 acres of the 246.96 acres (Conditional Use Site Plan Application CS-22-02 Calpine Kent County Solar Energy Center). The Application CS-22-02 is currently on hold as its consideration is tabled by Kent County Levy Court. IV. 2019 COMPREHENSIVE PLAN In the 2019 Comprehensive Plan, Chapter 13 – Growth and Annexation Plan outlines the annexation policy statements including benefits of annexation and annexation goals and policies. For lands considered for annexation, the Plan identifies distinct categories of annexation potential: Category 1 – High Priority Annexation Areas (enclaves); Category 2 – Priority Annexation Areas (0-10 years); Category 3 – Areas to Be considered for Long Term Annexation (5-10+ Years); and Areas of Concern. The Comprehensive Plan states that lands in the Areas of Concern are not intended for annexation (in the 10 year timeframe of the Plan), but the city has a vested interest in their future. Map 13-1: Potential Annexation Areas Plan Map depicts these areas in a colored coded format on a map. See also discussion of Annexation Plan Categories on pages 13-6 through 13-8. • The 2019 Comprehensive Plan depicts the subject area (two properties) as no identified Annexation Area and as an Area of Concern on Map 13-1. The Request is to revise the Annexation Plan Category for these two subject parcels near White Oak Road to Category 2. Designation as Category 2 – Priority Annexation Area would allow the City to consider annexation of the properties once the amendment process is complete. The second component of the Annexation Plan is the classification of Potential Land Uses for the Annexation Areas; see page 13-8 and Map 13-2: Potential Land Use for Annexation Areas. Map 13-2 depicts Land Use Classification for properties in the Annexation Areas of Category 1 and Category 2. The Land Use Classification is color coded on the map and utilizes the Land Use Classifications also found in the Land Development Plan (Chapter 12). The associated Table 12-1: Land Use and Zoning Matrix lists each Land Use Category and associated Zoning Districts. • With a change in the Annexation Plan Category of the subject parcels near White Oak Road to Category 2, then Potential Land Use Classifications are to be identified. The Request is to identify the Land Use Classification as Public & Private Utilities based on the intended use by the applicant. Regarding the Land Use Classification of Public & Private Utilities, this is discussed in Chapter 12 – Land Development Plan beginning on page 12-20. The general polices for and the statement on Public & Private Utilities are listed in the 2019 Comprehensive Plan excerpts presented as follows: 117

Paj 118

Item 7. MI-23-01A and B – Comprehensive Plan Amendments 2023: Amendments to Map 13-1 and Map 13-2 Lands of Calpine Holdings, LLC – Two Properties on White Oak Road DAC Report of February 8, 2023 Page 6 of 7 PUBLIC UTILITIES (Excerpt from 2019 Comprehensive Plan, page 12-20) Public Utilities include such systems as clean water, electricity production, and stormwater management as well as the removal of waste products. This makes the infrastructure that supports these activities vital to the well-being of the people who live, work, and play in the City of Dover. Similarly, the Comprehensive Plan must reflect the importance of continuing efforts to keep the maintenance and improvement of our Public Utilities infrastructure as a vital component of our plans moving forward. For the 2019 Comprehensive Plan, the City of Dover has created a new land use category of “Public and Private Utilities” to show the importance of dedicated land to facilitate the needs of day-to-day life in Dover. This land use category will be used where existing utility infrastructure is the primary use activity on the property. There is also the Source Water Protection Overlay Zone which notes where in the City the soils facilitate better than average reabsorption of groundwater. Assumptions: Public Utilities 1. The City will continue to be responsible for water, wastewater, electric and stormwater system, owning, operating and maintaining them for the benefit of residents, customers and businesses. 2. The City will plan for present and future needs as the City grows, assessing costs among users and development interests as meets the best interests of the public 3. The City will consistently strive to achieve and maintain full compliance with State and other regulatory requirements. Goal: Public Utilities Continue to maintain and improve/expand Dover’s Public Utilities in a manner that best facilitates the continued improvement in the quality of life for Dover’s residents. This will also better prepare the City of Dover for future expansion and growth. Policies: Public Utilities 1. Cooperate with other public and private providers to ensure system efficiency and capacity. 2. Actively assess emerging trends, technologies and regulatory schemes as these might impact the operation of the City’s utilities. Recommendations: Public Utilities The Land Development Plan reflects the existing locations of Public Utilities and private utility facilities. These encompass water, sewer, and electric system components such as water towers, pump stations, and electric substations. Examples of private utility facilities include the Dover Solar Park and the Garrison Energy Center. No enlargement of the land use area associated with Public Utilities is proposed at this time. 118

Paj 119

Item 7. MI-23-01A and B – Comprehensive Plan Amendments 2023: Amendments to Map 13-1 and Map 13-2 Lands of Calpine Holdings, LLC – Two Properties on White Oak Road DAC Report of February 8, 2023 Page 7 of 7 V. RECOMMENDATIONS OF THE PLANNING STAFF: The Planning Staff provides the following recommendations regarding the Comprehensive Plan Amendments 2023: MI-23-01A and MI-23-01B regarding the revision of the Annexation Plan Category and the designation of Land Use Classification. The applicant has requested a change in the Growth and Annexation Map of the 2019 Comprehensive Plan from an unidentified area and as an Area of Concern to Category 2 – Priority Annexation Area for the two properties. Following our review of the policies for Annexation in the 2019 Comprehensive Plan, as well as analysis of the surrounding land uses, proximity to City infrastructure, protection of natural resources, and economic development opportunities, Staff recommends approval of the Amendment A. The subject area is contiguous to lands within the city and in the vicinity of utility infrastructure along White Oak Road, Garrison Oak Drive and Long Point Road, in addition to being adjacent to the Garrison Oak Business and Technology Center. Additionally, the applicant has requested that the Potential Land Use Classification be identified for the two properties. The Land Use Classification of Public & Private Utilities appears to be consistent with nearby other electric generation facilities and the technology based development with the Garrison Oak Business and Technology Center. The proposed Land Use Category is compatible with the goals of the Comprehensive Plan associated with energy, green technology, and the development focus of the Garrison Business and Technology Center. Staff recommends approval of Amendment B. Planning Staff finds these requests in support of the overall set of goals established as a framework for the future of Dover in the 2019 Comprehensive Plan, Table 1-2: 2019 Comprehensive Plan Chapter Goals. (See attached.) This recommendation is being made without that benefit of hearing the comments of surrounding landowners and residents. A public hearing is required on this matter and the Planning Commission should give those comments consideration in addition to goals of the Comprehensive Plan. VI. ADVISORY COMMENTS 1) The Planning Staff notes the need for clarification of the size of the subject properties as there are differences in mapping of the parcel boundaries. A legal description of each parcel is required for the Annexation application. 2) The applicant shall be aware that approval of any Comprehensive Plan Amendment application does not represent Annexation approval or Site Development Plan approval. A separate review process is required for annexation; the applicant has made this application for annexation with AX-23-01. Also, a separate Site Development Plan must be submitted and approved if additional development activities are proposed on the property. 119

Paj 120

CITY OF DOVER Item 7. DEVELOPMENT ADVISORY COMMITTEE APPLICATION REVIEW COMMENTARY STAFF D.A.C. MEETING DATE: FEBRUARY 1, 2023 APPLICATION: Comprehensive Plan Amendments 2023 FILE #: MI-23-01 REVIEWING AGENCY: City of Dover Department of Public Works and Water & Wastewater CONTACT PERSON: Jason A. Lyon, P.E., Director of Water & Wastewater / Engineering Services CONTACT PHONE #: 302-736-7025 CONTACT PHONE #: jlyon@dover.de.us T HE S UBJECT P ROPOSAL HAS BEEN R EVIEWED FOR C ODE C OMPLIANCE , P LAN C ONFORMITY AND C OMPLETENESS IN A CCORDANCE WITH THIS A GENCY ’ S A UTHORITY AND A REA OF E XPERTISE . T HE F OLLOWING I TEMS HAVE BEEN I DENTIFIED AS E LEMENTS W HICH N EED TO BE A DDRESSED BY THE A PPLICANT : MI-23-01A: CONSIDERATION OF AMENDMENTS TO MAP 13-1: POTENTIAL ANNEXATION AREAS PLAN MAP CITY AND STATE CODE REQUIREMENTS SANITATION / STREETS / STORMWATER / WATER / WASTEWATER / GENERAL 1. Our office has no objections to the proposed annexation area adjustment for tax parcel LC-00-058.00-02-49.00-000 and tax parcel LC-00-058.00-02-48.00-000. RECOMMENDATIONS SUGGESTED AS CONDITIONS OF APPROVAL TO MEET CODE OBJECTIVES SANITATION / STREETS / STORMWATER / WATER / WASTEWATER / GENERAL 1. None ADVISORY COMMENTS TO THE APPLICANT SANITATION / STREETS / STORMWATER / WATER / WASTEWATER / GENERAL 1. None MI-23-01B: CONSIDERATION OF AMENDMENTS TO MAP 13-2: POTENTIAL LAND USE FOR ANNEXATION AREAS MAP CITY AND STATE CODE REQUIREMENTS SANITATION / STREETS / STORMWATER / WATER / WASTEWATER / GENERAL 1. Our office has no objections to the proposed land use classification for tax parcel LC-00-058.00-02-49.00-000 and tax parcel LC- 00-058.00-02-48.00-000. RECOMMENDATIONS SUGGESTED AS CONDITIONS OF APPROVAL TO MEET CODE OBJECTIVES SANITATION / STREETS / STORMWATER / WATER / WASTEWATER / GENERAL 1. None ADVISORY COMMENTS TO THE APPLICANT 120

Paj 121

Item 7. Comprehensive Plan Amendments 2023 File #: MI-23-01 February 1, 2023 Page 2 of 2 SANITATION / STREETS / STORMWATER / WATER / WASTEWATER / GENERAL 1. None I F Y OU H AVE A NY Q UESTIONS OR N EED TO D ISCUSS ANY OF THE A BOVE C OMMENTS , P LEASE C ALL THE A BOVE C ONTACT P ERSON AND THE P LANNING D EPARTMENT AS S OON AS P OSSIBLE . 121

Paj 122

Item 7. CITY OF DOVER ELECTRIC DEVELOPMENT ADVISORY COMMITTEE APPLICATION REVIEW COMMENTARY STAFF D.A.C. MEETING DATE: FEB 1, 2023 APPLICATION: Comprehensive Plan Amendments 2023 FILE #: MI-23-01 REVIEWING AGENCY: City of Dover Electric Department CONTACT PERSON: Shawn Burgett, Engineering Services & System Ops Superintendent CONTACT PHONE #: 302-674-7568 CONTACT EMAIL #: sburgett@dover.de.us T HE SUBJECT PROPOSAL HAS BEEN REVIEWED FOR CODE COMPLIANCE , PLAN CONFORMITY AND COMPLETENESS IN ACCORDANCE WITH THIS AGENCY ’ S AUTHORITY AND AREA OF EXPERTISE . T HE FOLLOWING ITEMS HAVE BEEN IDENTIFIED AS ELEMENTS WHICH NEED TO BE ADDRESSED BY THE APPLICANT : CITY AND STATE CODE REQUIREMENTS ELECTRIC 1. Electric Department has no objections to the Consideration of Amendments to Map 13-1: Potential Annexation Areas Plan Map. 2. Electric Department has no objections to the Consideration of Amendments to Map 13-2: Potential Land Use for Annexation. RECOMMENDATIONS SUGGESTED AS CONDITIONS OF APPROVAL TO MEET CODE OBJECTIVES 1. None ADVISORY COMMENTS TO THE APPLICANT 1. None I F YOU HAVE ANY QUESTIONS OR NEED TO DISCUSS ANY OF THE ABOVE COMMENTS , PLEASE CALL THE ABOVE CONTACT PERSON AND THE PLANNING DEPARTMENT AS SOON AS POSSIBLE . 122

Paj 123

C F MI-23-01 Item 7. I I T R CITY OF DOVER Y E DEVELOPMENT ADVISORY COMMITTEE O M F A APPLICATION REVIEW COMMENTARY R D.A.C. MEETING DATE: 02/01/23 D S O H V A E L R APPLICATION: Comprehensive Plan Amendments 2023 FILE #: MI-23-01 REVIEWING AGENCY: City of Dover, Office of the Fire Marshal CONTACT PERSON: Jason Osika, Fire Marshal PHONE #: (302) 736-4457 THE SUBJECT PROPOSAL HAS BEEN REVIEWED FOR CODE COMPLIANCE, PLAN CONFORMITY, AND COMPLETENESS IN ACCORDANCE WITH THIS AGENCY’S AUTHORITY AND AREA OF EXPERTISE. THE FOLLOWING ITEMS HAVE BEEN IDENTIFIED AS ELEMENTS WHICH NEED TO BE ADDRESS BY THE APPLICANT: CITY AND STATE CODE REQUIREMENTS: 1. Proposal is a series of amendments to the 2019 comprehensive plan, this office has no objections 2. Every house, building or structure used or intended for use as living quarters or as a place for conducting business, and having any wall facing or abutting any public or private street or alley, shall have displayed on that wall, in legible, easily read characters which are of contrasting color to the background, the proper street number for such house, building, or structure in accordance with the following: One-family and two-family residential structures, height, the number shall measure a minimum of four inches in height, location, the number shall be placed on the house above or to the left or right of the front entrance, color, the number shall be contrasting to the background color, Arabic numerals, all numbers shall be Arabic numerals. Multiple-family dwellings, measurements, the number shall measure a minimum of six inches when identifying individual apartments with exterior doors, and 12 inches when identifying buildings with apartment complexes where there are two or more buildings not assigned street addresses. Individual buildings with street addresses shall have numbers measuring six inches, location, numbers shall be placed either in the center of the building or on the street end of the building so as to be visible from either the public or private street or from the parking lot, color, numbers shall be contrasting to the background color, Arabic numerals, all numbers used shall be Arabic numerals. Commercial, industrial and office buildings, height, the numbers shall measure a minimum of 12 inches in height, location generally, numbers shall be placed either in the center of the building or on the 123

Paj 124

Item 7. street end of the building so as to be visible from either the public or private street or from the parking lot, property line or driveway, should the building be located far enough from a public or private road so that the numbers are not clearly visible from the street, then the street address shall also be posted on the property at or near the property line or driveway to said building, color; each building, numbers shall be contrasting to the background color and shall be placed on each building in the complex, Arabic numerals, all numbers used shall be Arabic numerals, Shopping centers. Shopping centers consisting of two or more stores shall have a tenant or suite number affixed to the front of the tenant space and on the outside of the rear door which corresponds with that tenant space. Numbers shall measure six inches in height. (City of Dover Code of Ordinances, 98-344) 3. Project to be completed per approved Site Plan. ADDITIONAL / SPECIFIC REQUIREMENTS TO OBTAIN APPROVAL: 1. This annexation will affect current fire districts. APPLICABLE CODES LISTED BELOW (NOT LIMITED TO): 2021 NFPA 1 Fire Code (NFPA; National Fire Protection Association) 2021 NFPA 101 Life Safety Code (NFPA; National Fire Protection Association) 2019 NFPA 72 National Fire Alarm and Signaling Code (NFPA; National Fire Protection Association) 2019 NFPA 13 Installation of Sprinkler Systems (NFPA; National Fire Protection Association) 2009 IBC (International Building Code) Latest editions of all other NFPA Codes as defined by the Delaware State Fire Prevention Regulations 2021 Delaware State Fire Prevention Regulations City of Dover Code of Ordinances *If you have any questions or need to discuss any of the above comments, please call the above contact person listed. 124

Paj 125

Item 7. CITY OF DOVER D E DEVELOPMENT ADVISORY COMMITTEE L APPLICATION REVIEW COMMENTARY D O T =============================================================== APPLICATION: Amendments to Map 13-1: Potential Annexation Areas Plan Map FILE#: MI-23-01 REVIEWING AGENCY: DelDOT CONTACT PERSON: Joshua Johnson PHONE#: 302-760-2141 =============================================================== THE SUBJECT PROPOSAL HAS BEEN REVIEWED FOR CODE COMPLIANCE, PLAN CONFORMITY AND COMPLETENESS IN ACCORDANCE WITH THIS AGENCY'S AUTHORITY AND AREA OF EXPERTISE. THE FOLLOWING ITEMS HAVE BEEN IDENTIFIED AS ELEMENTS WHICH NEED TO BE ADDRESSED BY THE APPLICANT: CITY & STATE CODE REQUIREMENTS: No person, firm, corporation or the like shall construct, open, reconstruct, maintain, modify or use any crossing or entrance onto a state-maintained highway, street or road, including any drainage modifications leading into or carried by the highway drainage system, without first having complied with standards and regulations adopted by the Department and having obtained a permit issued by the Department. Please contact the Delaware Department of Transportation - Development Coordination section to begin permit process. RECOMMENDATIONS SUGGESTED AS CONDITIONS OF APPROVAL TO MEET CODE OBJECTIVES: ADVISORY COMMENTS TO THE APPLICANT: 1. DelDOT has no comment on this application. 125

Paj 126

KENT CONSERVATION DISTRICT Item 7. 1679 SOUTH DUPONT HIGHWAY • DOVER, DELAWARE 19901• (302) 608-5370 • WWW.KENTCD.ORG CITY OF DOVER DEVELOPMENT ADVISORY COMMITTEE APPLICATION REVIEW COMMENTARY FEBRUARY 2023 APPLICATION: Comprehensive Plan Amendments 2023 FILE #: MI-23-01 REVIEWING AGENCY: Kent Conservation District CONTACT PERSON: Kate Owens PHONE: (302) 608 – 5370 EMAIL: stormwater@kentcd.org THE SUBJECT PROPOSAL HAS BEEN REVIEWED FOR CODE COMPLIANCE, PLAN CONFORMITY AND COMPLETENESS IN ACCORDANCE WITH THIS AGENCY’S AUTHORITY AND AREA OF EXPERTISE. THE FOLLOWING ITEMS HAVE BEEN IDENTIFIED AS ELEMENTS WHICH NEED TO BE ADDRESSED BY THE APPLICANT: Source: 2019 Delaware Sediment and Stormwater Regulations CITY AND STATE CODE REQUIREMENTS: Kent Conservation District has no objection to the proposed Amendments, Map 13-1: Potential Annexation Areas Plan Map and Map 13-2: Potential Land Use for Annexation Areas, to the 2019 Comprehensive Plan, as amended. 126

Paj 127

Item 7. Adopted – 1.13.2020 Chapter 1 Introduction Dover 2019 Comprehensive Plan Table 1-2: 2019 Comprehensive Plan Chapter Goals Goal 1: Protect the Natural Environment Natural Goal 2: Improve Watershed Quality Resources and Goal 3: Improve Air Quality Environmental Goal 4: Encourage Green Development and Sustainable Energy Protection Practices Goal 5: Preserve Access to Open Space and Scenic Resources Goal 1: Preserve and Protect Historic Resources Historic Goal 2: Provide and Promote Incentives for Preservation Activities Preservation Goal 3: Increase Public Information on Historic Resources Goal 4: Collaborate with Diverse Groups and Governments Goal 1: Proactively Maintain Existing Infrastructure and Expand Infrastructure When Beneficial Public Utilities Goal 2: Enhance Infrastructure to Meet Community Needs and Goal 3: Meet or Exceed the State and Federal Requirements of the Infrastructure NPDES Permit and Stormwater Management Goal 4: Continue to Strive for Excellent Service Goal 1: Provide and Maintain Quality City Services Community Goal 2: Invest in City Owned Resources Services and Goal 3: Provide a System of Interconnected Open Space Areas Facilities and Recreational Opportunities Goal 4: Prepare Effectively for Disasters Goal 1: Preserve and Maintain the Existing Transportation System Goal 2: Increase Coordination with Agencies Transportation Goal 3: Develop and Expand Alternate Modes of Transportation Goal 4: Create Recommendations and Policies for Roadways and Development 2019 Comprehensive Plan Adopted 1.13.2020 Page 1 - 11 127

Paj 128

Item 7. Adopted – 1.13.2020 Chapter 1 Introduction Dover 2019 Comprehensive Plan Goal 1: Attract and Retain High-Paying Quality Jobs by Targeting Business Sectors that are Best Suited for Dover and Kent County Goal 2: Encourage the Economic Revitalization and Integrity of Dover’s Downtown, including the Historic Core and the Traditional Communities Surrounding It Goal 3: Promote the Revitalization and Redevelopment of the Center City Economic Goal 4: Ensure that Land Development, Zoning, Infrastructure and Development Other Development Requirements Encourage the Economic Development and Uses Desired Goal 5: Actively market the Garrison Oak Business and Technology Center (GOBTC) Goal 6: Pursue Economic Development Linked to Active Recreation Goal 7: Pursue Economic Development Linked to Improved Healthy Food Access Goal 1: Encourage Balanced Housing Opportunities for all Residents of the City Housing & Goal 2: Preserve Existing Housing Stock Community Development Goal 3: Provide Safe and Healthy Livable Neighborhoods Goal 4: Provide Homeownership Opportunities Source: 2019 Comprehensive Plan Page 1- 12 - 2019 Comprehensive Plan Adopted 1.13.2020 128

Paj 129

Item 7. City of Dover, DE 2019 Comprehensive Plan File: M:\PS_DATA\2018_Comp_Plan_Draft_Maps\Comp_Plan_2018_FINAL_MXDS\Map 13-1 Potential Annexation Areas.mxd Map 13-1: Potential Annexation Areas As Adopted on January 13, 2020 0 2,500 LEGEND 5,000 Feet ¯ Dover Boundary Municipal Boundaries Roads Hydrology Water Bodies 2019 Annexation Plan Category Category 1 - High Priority Category 2 - Priority Category 3 - Long Term Annexation Areas of Concern 0 3,000 6,000 Feet Inset Map PAPER MAP DISCLAIMER: By acceptance of this map material you agree to the following: This map material is made available by the City of Dover, Delaware as a public service. The material is for reference purposes only, and the City makes no warranty, re presentation, or guaranty as to the accuracy of the material, including its accuracy, availability, use, and misuse. In no event shall the City be liable for any direct or indirect damages suffered by the Recipient or others arising from any inadequacies of the digital data or the Recipient's use of this data. The material is in the public domain and may be copied without permission. Citation to the source would be appreciated. Any errors or omissions in the material should be reported to the City of Dover, Delaware's Public Works GIS 129 Division.

Paj 130

MI-23-01 Comprehensive Plan Amendment 2023 Request Locations Item 7. File: I:\DAC\2023 Applications\MI-23-01 Comp Plan Amendment - Annexation Calpine\MI-23-01 Mapping\Map 13-1_Potential (City of Dover, DE 2019 Comprehensive Plan) Map 13-1: Potential Annexation Areas Request Date: 12/15/2022 0 3,000 LEGEND Hydrology 6,000 Feet ¯ Proposed Amendment Area on White Oak Road Water Bodies Roads Municipal Boundaries Dover Boundary 2019 Annexation Plan Category Category 1 - High Priority Category 2 - Priority Category 3 - Long Term Annexation Areas of Concern 0 4,000 8,000 Feet Inset Map PAPER MAP DISCLAIMER: By acceptance of this map material you agree to the following: This map material is made available by the City of Dover, Delaware as a public service. The material is for reference purposes only, and the City makes no warranty, re presentation, or guaranty as to the accuracy of the material, including its accuracy, availability, use, and misuse. In no event shall the City be liable for any direct or indirect damages suffered by the Recipient or others arising from any inadequacies of the digital data or the Recipient's use of this data. The material is in the public domain and may be copied without permission. Citation to the source would be appreciated. Any errors or omissions in the material should be reported to the City of Dover, Delaware's Public Works GIS 130 Division.

Paj 131

City of Dover MI-23-01A Item 7. Department of Planning & Inspections 2023 Comprehensive Plan Amendment Current Designation Proposed Designation File: MI-23-01 Comprehensive Plan Amendment 2023 Potential Annexation Areas Dover Parcels Location: 3015 White Oak Road & unaddressed parcel near White Oak Road Category Kent County Parcels Plan Type: Comprehensive Plan Amendment A « Category 1 - High Priority Dover Boundary Current Annexation Area: Area of Concern and unidentified area Proposed Annexation: Category 2: Priority Annexation Area Category 2 - Priority Owner: Calpine Holdings, LLC Category 3 - Long Term Annexation Date: 1/5/2023 131 0 800 1,600 3,200 Feet Areas of Concern

Paj 132

Item 7. City of Dover, DE 2019 Comprehensive Plan File: M:\PS_DATA\2018_Comp_Plan_Draft_Maps\Comp_Plan_2018_FINAL_MXDS\Map 13-2 Potential Land Use for Annexation Areas.mxd Map 13-2: Potential Land Use for Annexation Areas As Adopted on January 13, 2020 0 2,500 LEGEND Dover Boundary 5,000 Feet ¯ Municipal Boundaries Roads Hydrology Water Bodies 2019 Annexation Areas Land Use Agriculture Commercial Entertainment Commercial High Intensity Commercial Low Intensity Industrial Mixed Use Office and Office Park Open Space Residential Low Density Residential Medium Density Right-Of-Way 0 3,000 6,000 Feet Inset Map PAPER MAP DISCLAIMER: By acceptance of this map material you agree to the following: This map material is made available by the City of Dover, Delaware as a public service. The material is for reference purposes only, and the City makes no warranty, re presentation, or guaranty as to the accuracy of the material, including its accuracy, availability, use, and misuse. In no event shall the City be liable for any direct or indirect damages suffered by the Recipient or others arising from any inadequacies of the digital data or the Recipient's use of this data. The material is in the public domain and may be copied without permission. Citation to the source would be appreciated. Any errors or omissions in the material should be reported to the City of Dover, Delaware's Public Works GIS 132 Division.

Paj 133

File: M:\PS_DATA\2018_Comp_Plan_Draft_Maps\Comp_Plan_2018_FINAL_MXDS\Map 13-2 Potential Land Use for Annexation Areas.mxd MI-23-01 Comprehensive Plan Amendment 2023 Request Locations Item 7. (City of Dover, DE 2019 Comprehensive Plan) Map 13-2: Potential Land Use for Annexation Areas Request Date: 12/15/2022 0 2,500 Dover Boundary LEGEND Municipal Boundaries 5,000 Feet ¯ Proposed Amendment Area on White Oak Road Roads Hydrology Water Bodies 2019 Annexation Areas Land Use Agriculture Commercial Entertainment Commercial High Intensity Commercial Low Intensity Industrial Mixed Use Office and Office Park Open Space Residential Low Density Residential Medium Density Right-Of-Way Public and Private Utilities 0 3,000 6,000 Feet Inset Map PAPER MAP DISCLAIMER: By acceptance of this map material you agree to the following: This map material is made available by the City of Dover, Delaware as a public service. The material is for reference purposes only, and the City makes no warranty, re presentation, or guaranty as to the accuracy of the material, including its accuracy, availability, use, and misuse. In no event shall the City be liable for any direct or indirect damages suffered by the Recipient or others arising from any inadequacies of the digital data or the Recipient's use of this data. The material is in the public domain and may be copied without permission. Citation to the source would be appreciated. Any errors or omissions in the material should be reported to the City of Dover, Delaware's Public Works GIS 133 Division.

Paj 134

City of Dover MI-23-01B Item 7. Department of Planning & Inspections 2023 Comprehensive Plan Amendment Current Designation Proposed Designation Site Site File: MI-23-01B Comprehensive Plan Amendments 2023 Legend Location: 3015 White Oak Road & unaddressed parcel near White Oak Road Dover Parcels Commercial High Intensity Open Space Plan Type: Comprehensive Plan Amendment B « Dover Boundary Commercial Low Intensity Residential Low Density Current Land Use: None Proposed Land Use Classifcation: Public & Private Utilities Public and Private Utilities Industrial Residential Medium Density Owners: Calpine Holdings LLC Agriculture Mixed Use Right-Of-Way Date: 1/5/2023 0 625 1,250 2,500 Feet Commercial Entertainment Office and Office Park 134

Paj 135

Item 7. Comp Plan Amendment Request Consistent with Green Energy/Environmental/Tech Park Economic Goals of Dover 2019/2020 Comprehensive Plan Applicant Calpine Holding’s request for a Comprehensive Plan amendment to permit annexation of its lands adjacent to the City of Dover Garrison Oak Business and Technology Center with the same IPM-2 Technology Park zoning is consistent with and supports the following referenced goals of the Dover Comp Plan (and see attached supportive excerpt pages from the Dover Comp Plan): The Application is consistent with the following Comp Plan Goals of the 2019/2020 Plan: • Solar Energy production will support Comp Plan Goals of Protecting the Natural Environment, Improving Air Quality and Encouraging Green Development and Sustainable Energy Practices • Solar Energy production will support the Comp Plan Goals of promoting forward-looking, environmentally conscious companies • Solar Energy production supports the Comp Plan Green Energy Goals • Solar Energy production adjacent to the existing Garrison Oak Business and Technology Center (GOBTC) with an identical IPM-2 Zoning supports the Comp Plan goals for GOBTC as a location for large Green industries • Solar Energy production by private industry supports the Comp Plan goal favoring the expansion of Private Energy producers in the City at the GOBTC • A large part of the proposed annexation area is already an “Area of Concern” that supports annexation into the City under the Comp Plan Excerpts from the City of Dover Comprehensive Plan are Attached which are supportive of the Applicants intended use as a Solar Energy production facility at this location immediately adjacent to land currently zoned for the same uses (IPM-2) 135

Paj 136

Item 7. Adjacent City of Dover Parcels Zoning Analysis The Applicant’s site is immediately adjacent to the City of Dover Garrison Oak Business and Technology Park which is zoned IPM-2 and which contains a Solar Energy facility as well as a Gas Turbine energy facility among other uses. The Applicant seeks the identical IPM-2 zoning so its adjoining property can install a Solar Energy facility as well. These adjacent uses will be completely compatible and desirable under a zoning analysis. The passive nature of the proposed Solar Energy use for the applicants property will also be compatible with the RM and R8 zoned City parcels that are located Southwest of the applicants property since the facility will generate no traffic, odors or sound. A map of these nearby City parcels and their respective zonings is attached to the application. 136

Paj 137

Item 7. &LW\RI'RYHU &2035(+(16,9(3/$1 &LW\RI'RYHU'HODZDUH Planning for a Bigger Better Dover $'237('² 137

Paj 138

Item 7. Adopted – 1.13.2020 Chapter 1 Introduction Dover 2019 Comprehensive Plan for the progress of the City. Between 2003 and 2008 there were several amendments to the 2003 Comprehensive Plan Update such as text amendments to the Transportation Plan as well as Land Development Plan map updates. 2008 Dover Comprehensive Plan The 2008 Dover Comprehensive Plan sought to take the essential elements of the 2003 Plan Update and provide a more aggressive plan of action for the City. As in the 2003 Plan Update, citizen participation and public input regarding goals, recommendations and growth and annexation areas played a large part in the formation of the 2008 Plan. While many chapters remained consistent in subject, some chapters were expanded upon individually. With the increase in population within the City and the City providing essential services to more residents and businesses, as well as the expansion of the utility system, Public Utilities & Community Infrastructure Chapter was divided. Some information became the Public Utilities and Infrastructure Plan Chapter in order to address all infrastructure and utility system and services within Dover. Facilities and programs offered to residents became a part of the Community Services and Facilities Chapter. This chapter sought to address public safety, Parks & Recreation programs and services, and community services. Economic development was one of the most pressing issues in Dover. To this end, Economic Development became a new chapter developed by an Economic Development Task Force Committee. The Community Development component addressed in the 2003 Plan became a part of the Housing and Community Development Chapter in 2008. The 2008 Dover Comprehensive Plan used the information gathered and analyzed through public participation workshops, City Commissions and Council input and comprehensive history of the previous five years to set forth goals and recommendations. ACCOMPLISHMENTS SINCE 2008 As part of the efforts to develop the 2019 Comprehensive Plan project, Staff looked back over the last ten years (2008-2018) to document significant accomplishments that occurred in the City. A number of these items were outlined as Goals and Recommendations or Action Items in the 2008 Dover Comprehensive Plan. The following chart summarizes these Accomplishments by chapter topic. This summary can be viewed as a type of Report Card which allows us to best see how well we worked towards and achieved our goals, and where there is still room for improvement. Table 1-1: Accomplishments 2008-2018 (Report Card Items) Accomplishment 1: Updated Tree Planting and Preservation Ordinance of the Zoning Ordinance. Natural Resources and Accomplishment 2: Updated Environmental Protection section of the Zoning Ordinance, particularly with regards to floodplains and Environmental wetlands. Protection Accomplishment 3: Adopted Solar and Wind Energy section of Zoning Ordinance. Page 1- 6 - 2019 Comprehensive Plan Adopted 1.13.2020 138

Paj 139

Item 7. Adopted – 1.13.2020 Chapter 1 Introduction Dover 2019 Comprehensive Plan Accomplishment 5: Developed the Dover Capital Gateway Plan in 2015. Accomplishment 6: Conducted a Downtown Dover Parking Study (2017-18). Accomplishment 7: Expanded bus service. Accomplishment 8: Began construction on the Senator Bikeway project between Weston Drive and Cecil Street. Accomplishment 9: Improved safety of US Route 13 crossings near Delaware State University. Accomplishment 1: Several separate groups merged to create the Downtown Dover Partnership (DDP). Accomplishment 2: Began participation in Restoring Central Dover in 2013. Accomplishment 3: The City of Dover was designated a Downtown Development District by Governor Markell in January 2015. Economic Accomplishment 4: The City of Dover has invested in further Development infrastructure and marketing of the Garrison Oak Business and Technology Center. Accomplishment 5: Adopted the IPM-3 (Industrial Park and Manufacturing Zone – Industrial Aviation and Aeronautics Center) to attract aeronautics and aviation related business to Dover. Accomplishment 6: Began collaborative work in the Kent Economic Partnership. Accomplishment 1: Adopted the 2015-2019 Community Development Block Grant (CDBG) Consolidated Plan. Accomplishment 2: Adopted the 2011 Statewide Analysis of Impediments to Fair Housing Choice. Accomplishment 3: Received $1.5 million in Neighborhood Housing & Stabilization Program (NSP) funding in 2010 to purchase abandoned Community and foreclosed properties in the City to renovate and sell to qualifying Development families. Accomplishment 4: Received $100,000 in CDBG-R funding in 2010 to complete infrastructure projects in low to moderate income neighborhoods. Accomplishment 5: Utilized CDBG funding in 2009 to make ADA improvements to city-owned buildings. 2019 Comprehensive Plan Adopted 1.13.2020 Page 1 - 9 139

Paj 140

Item 7. Adopted – 1.13.2020 Chapter 1 Introduction Dover 2019 Comprehensive Plan Table 1-2: 2019 Comprehensive Plan Chapter Goals Goal 1: Protect the Natural Environment Natural Goal 2: Improve Watershed Quality Resources and Goal 3: Improve Air Quality Environmental Goal 4: Encourage Green Development and Sustainable Energy Protection Practices Goal 5: Preserve Access to Open Space and Scenic Resources Goal 1: Preserve and Protect Historic Resources Historic Goal 2: Provide and Promote Incentives for Preservation Activities Preservation Goal 3: Increase Public Information on Historic Resources Goal 4: Collaborate with Diverse Groups and Governments Goal 1: Proactively Maintain Existing Infrastructure and Expand Infrastructure When Beneficial Public Utilities Goal 2: Enhance Infrastructure to Meet Community Needs and Goal 3: Meet or Exceed the State and Federal Requirements of the Infrastructure NPDES Permit and Stormwater Management Goal 4: Continue to Strive for Excellent Service Goal 1: Provide and Maintain Quality City Services Community Goal 2: Invest in City Owned Resources Services and Goal 3: Provide a System of Interconnected Open Space Areas Facilities and Recreational Opportunities Goal 4: Prepare Effectively for Disasters Goal 1: Preserve and Maintain the Existing Transportation System Goal 2: Increase Coordination with Agencies Transportation Goal 3: Develop and Expand Alternate Modes of Transportation Goal 4: Create Recommendations and Policies for Roadways and Development 2019 Comprehensive Plan Adopted 1.13.2020 Page 1 - 11 140

Paj 141

Item 7. Adopted – 1.13.2020 Chapter 1 Introduction Dover 2019 Comprehensive Plan Goal 1: Attract and Retain High-Paying Quality Jobs by Targeting Business Sectors that are Best Suited for Dover and Kent County Goal 2: Encourage the Economic Revitalization and Integrity of Dover’s Downtown, including the Historic Core and the Traditional Communities Surrounding It Goal 3: Promote the Revitalization and Redevelopment of the Center City Economic Goal 4: Ensure that Land Development, Zoning, Infrastructure and Development Other Development Requirements Encourage the Economic Development and Uses Desired Goal 5: Actively market the Garrison Oak Business and Technology Center (GOBTC) Goal 6: Pursue Economic Development Linked to Active Recreation Goal 7: Pursue Economic Development Linked to Improved Healthy Food Access Goal 1: Encourage Balanced Housing Opportunities for all Residents of the City Housing & Goal 2: Preserve Existing Housing Stock Community Development Goal 3: Provide Safe and Healthy Livable Neighborhoods Goal 4: Provide Homeownership Opportunities Source: 2019 Comprehensive Plan Page 1- 12 - 2019 Comprehensive Plan Adopted 1.13.2020 141

Paj 142

Item 7. Adopted – 1.13.2020 Chapter 2 Patterns of Change Dover 2019 Comprehensive Plan Chapter 2 PATTERNS OF CHANGE PAT T E R N S O F C H A N G E : L A N D U S E A N D D E V E L O P M E N T AC T I V I T Y APPLICATIONS FOR DEVELOPMENT ACTIVITY Over the period of 2008-2018, the number of plan review and approvals resulting in construction projects was somewhat slower than the previous five years (2003-2007) but it remains steady. Over 2.5 million square feet of nonresidential development was approved including several Master Plans outlining phased multi-year projects. Although the City only annexed 269.58 acres in the ten-year period, Dover remains the commercial and employment core of central Delaware. Institutional, office and retail land uses have dominated new development. Residential construction has seen increased focus on the build-out of previously platted subdivisions rather than applications for new subdivision development. The focus of residential development over the last ten years is the development of multi-family units (apartments). Retail and development have been concentrated along main transportation corridors, while residential development has been in several areas of the City. Institutional uses have expanded to keep pace with the demands of the growing City and Dover’s industrial base has continued to expand with numerous industrial park developments being constructed and enlarged. With the tracking of applications, the pace and type of development activity can be observed. Table 2-1 illustrates the number of applications submitted to the City for review between 2008 and 2018. This table, along with subsequent tables, shows the changes in development activity and uses throughout the City. In the previous six-year period (2002-2007), there were in total 703 applications. It is also noted that there were refinements to the application review process in 2011 (Ordinance #2011-14). These refinements simplified the Site Plan review processes allowing certain projects to complete Zoning Review as part of the Building Permit process when renovating an existing building. The building size and impervious area size that triggered Planning Commission review with a public hearing were also amended making some applications eligible for an Administrative Site Plan review process. 2019 Comprehensive Plan Adopted 1.13.2020 Page 2 - 1 142

Paj 143

Item 7. Adopted – 1.13.2020 Chapter 2 Patterns of Change Dover 2019 Comprehensive Plan uses have followed residential development along DE Route 8 in western Dover. In the recent few years, the Bay Road corridor also has been a focus of redevelopment activity. Additionally, the City is aware of the State policy of discouraging development on lands east of State Route 1 (with the exception of Garrison Oak Business and Technology Park). Governmental and institutional uses are extensive throughout central Dover including the State Capital Complex, Bayhealth Medical Center, and Wesley College. Major institutional uses outside the traditional core area include Delaware State University, Delaware Technical & Community College, Wilmington University Campus, Delaware Department of Transportation (DelDOT) administrative campus (Danner Campus), and Kent County Levy Court administrative building. Major industrial uses lie along the railroad line within the south-central planning region and north of Dover Air Force Base. Industrial land uses occupy a small percentage of total area. There are several large industrial complexes including KraftHeinz Foods, Energizer (Playtex Products), former Playtex Apparel facility, Enterprise Business Park, Proctor & Gamble, the Kent County Aeropark, and locations along Horsepond Road and Lafferty Lane. Numerous vacant developable tracts of land exist within the City limits and are distributed throughout the urbanized area. Peripheral areas within and bordering the City are rapidly beginning to develop to the north and west, while the eastern areas of the City have remained predominantly commercial west of State Route 1 and agricultural east of State Route 1, except for two residential subdivisions near the State Route 1 and Route 8 interchange. The southern area of Dover is largely suburban, consisting of numerous single-family neighborhoods. Residential Development Residential development over the past ten years has been characterized by the continued construction to build-out earlier subdivisions (pre-2008 applications), the development of multi- family (apartment) complexes, and the renovation of existing multi-family (apartment) complexes. Residential development has not kept pace with the growing commercial sector likely due to lower development costs and alternative housing selection options beyond City limits. The City has reviewed a limited number of subdivision approvals either in the design or final plan process since 2008. The focus in the planning period was the development review of multi-family apartment complexes. These included Leander Lakes Apartments, The Arbors, Tall Pines, Dove View (The Grande) Apartments Planned Neighborhood Design: Senior Citizen Housing Option (PND: SCHO), Luther Village III Planned Neighborhood Design: Senior Citizen Housing Option (PND: SCHO), and Blue Hen Apartments. There were also several existing multi-family complexes that were reviewed for redevelopment activities: Walker Woods (Village at McKee Branch); Liberty Court; and Whatcoat Apartments (Preserve at Whatcoat). Table 2-5 shows the number of single-family lots and multi-family units approved from 2008 to 2018 in comparison to totals from 2003 to 2007. 2019 Comprehensive Plan Adopted 1.13.2020 Page 2 - 5 143

Paj 144

Item 7. Adopted – 1.13.2020 Chapter 5 Natural Resources and Environmental Protection Dover 2019 Comprehensive Plan Emissions from automobile sources are more difficult for the City to influence. In some ways, the hard work has already been done by others. For instance, fuel and engine technologies have improved over decades in response to pressure from EPA regulations, so that according to the EPA new cars made today are well over 90% cleaner than ones made in 1970. Efficiency gains can only reduce emissions so much, however, especially with the number of cars on the road increasing during that same time. The City has several strategies for checking the growth of auto use in Dover, primarily by providing transportation alternatives and ensuring Dover’s residents have ample opportunity to use them. x The Land Development Plan encourages mixed-use development in Downtown Dover and provides for various well integrated residential and employment centers throughout the City. Additional housing options with Mixed Use areas will promote the desirability of living near work. See Chapter 12 – Land Development Plan for more information. x Opportunities for increased use of public transportation are supported. x Numerous bicycle and pedestrian improvements are being suggested and implemented by DelDOT, the Dover/Kent County MPO and the City; and a major strategy of this plan is to encourage interconnections to provide a continuous bicycle and pedestrian transportation system. x This Plan contains an Economic Development Chapter which seeks to attract business and industry to Dover. More employment opportunities may lead to more people living and working in the same community. Employees who live and work in Dover may find commuting by transit, bicycle or as pedestrians to be viable options. See Chapter 10 – Economic Development for more information. The City recognizes that most residents will still use cars despite transportation alternatives being available. Therefore, in addition to the above, the City also supports the development of new automotive technologies which will further reduce auto emissions. The most significant development on the horizon is efficient and affordable electric vehicles. A potentially massive increase in the number of electric vehicles on the road is likely to occur within this Plan’s timeframe. Discussion of how the City can adapt to this coming trend can be found in the Chapter 9 - Transportation and the Chapter 7 - Utilities. Water Quality and Total Maximum Daily Loads Dover is located within the St. Jones River, Leipsic River, and Little Creek Watersheds which are impaired according to Section 303(d) of the Clean Water Act. Under Section 303(d) of the Federal Clean Water Act, states are required to identify all impaired waters and establish total maximum daily loads to restore their beneficial uses (e.g., swimming, fishing, and drinking water). A TMDL (Total Maximum Daily Load) defines the amount of a given pollutant that may be discharged to a water body from point, nonpoint, and natural background sources and still allow for attainment or maintenance of the applicable narrative and numerical water quality standards. A TMDL is the sum of the individual Waste Load Applications (WLAs) for point sources and Load Allocations (LAs) for nonpoint sources and natural background sources of pollution. A TMDL may include a reasonable margin of safety (MOS) to account for uncertainties regarding the relationship between mass loading and resulting water quality. In short, a TMDL matches the strength, location and timing of pollution sources within a watershed with the inherent ability of the receiving water to assimilate the pollutant without adverse impact. A Pollution Control Strategy (PCS) identifies the Page 5-6 – 2019 Comprehensive Plan Adopted 1.13.2020 144

Paj 145

Item 7. Adopted – 1.13.2020 Chapter 5 Natural Resources and Environmental Protection Dover 2019 Comprehensive Plan accommodations for small solar and wind energy systems in the Zoning Ordinance (Article 5, Section 20). These provisions allow homeowners and businesses to install their own power systems, which in turn generate clean on-site energy to reduce the amount of electricity they must buy from the power grid. The City has decided to retire the McKee Run Generation Station effective May 31, 2021. The VanSant Generating Station will likely run for the foreseeable future; however, it is rarely used, even when the demand is high. As the City plans for electric supply in the future, renewable resources, principally solar from large scale facilities, are becoming more financially attractive which will benefit both the environment and ratepayers Reducing overall energy consumption is another route to reducing the climate change impact caused by the City’s power demand. This can be done in many ways; one example is reducing the energy consumption of buildings by improving the efficiency of their heating systems. The Delaware Weatherization Assistance Program helps homeowners burdened by utility bills reduce the amount of heat escaping their homes by adding insulation, patching cracks, and fixing ventilation. Because less heat escapes, the homes’ systems do not have to work as hard to heat the homes, and so consume less energy. There are other programs available that help residents and businesses improve the energy efficiency of their buildings. DNREC’s Energy Efficiency Investment Fund, for instance, provides grants to businesses that either follow a prescribed path or come up with their own innovative way to reduce their energy consumption. Finally, the City can reduce its contribution from industrial sources by working to attract manufacturing and technology companies that are committed to the practice of green industry. The City previously demonstrated its commitment to attracting such industry by developing the Garrison Oak Business and Technology Center, which contains fifteen large, shovel-ready lots (four now developed) ideal for technology firms. In 2019, the City renewed its marketing efforts for the Park in hopes of attracting buyers for the remaining lots. Focusing the City’s economic development efforts on green manufacturing and technology firms will help ensure the demand for new industry within the City is fulfilled by forward-looking, environmentally conscious companies instead of those merely practicing “business as usual.” Page 5-14 – 2019 Comprehensive Plan Adopted 1.13.2020 145

Paj 146

Item 7. Adopted – 1.13.2020 Chapter 5 Natural Resources and Environmental Protection Dover 2019 Comprehensive Plan x Evaluate the City’s Performance Standards and the lists of permitted and prohibited uses in the City’s industrial zones for possible code updates to ensure the City is both friendly to industrial development and up to date with air quality standards. Goal 4: Encourage Green Development and Sustainable Energy Practices Use code amendments and/or policy amendments and revisions to encourage environmentally sensitive development and allow emerging green trends to be easily established and grown in the City. Recommendation 8: Research and Implement Sustainable Development Practices x Conduct a “vulnerability assessment” of the City to determine which people and places within Dover are most at-risk from climate change pressures including sea-level rise, increased heavy precipitation, and rising temperatures. This assessment can be used to help the City decide what forms of sustainable development practices need the most encouragement. x Evaluate ways to incentivize use of green practices in new development. Some green development practices include infill development, higher densities in areas with access to transit, and green building construction techniques. x Evaluate ways to incentivize improvements to the energy performance of existing buildings. Energy performance improvements can come from adding insulation to reduce dependence on heating and cooling systems, installing energy-efficient appliances, and other changes. x Catalog existing green development and green energy incentives offered by the State and federal governments and other sources and evaluate ways Dover can leverage these incentives. Goal 5: Preserve Access to Open Space and Scenic Resources Protect open spaces and scenic resources in the City while also preserving reasonable public access. While protected open spaces can in turn protect developed areas by absorbing the most direct impacts of climate change, open spaces and scenic resources also have value for their health and recreation benefits to residents and visitors. Recommendation 9: Support City Policies Allowing Public Access and Utilization of Open Space and Scenic Resources x Evaluate the Dover Code of Ordinances and other legislation to identify provisions that potentially limit public access to nature (e.g. parking requirements, use restrictions, fencing and screening requirements, etc.). x Determine what valuable open spaces and scenic resources in the City currently have limited public access and evaluate options for improving access to these areas. x Improve pedestrian, bicycle, and transit networks to parks, natural areas, and the Historic District. x Support programs that promote access to nature (e.g. environmental education programs, Scouts programs). 2019 Comprehensive Plan Adopted 1.13.2020 Page 5-17 146

Paj 147

Item 7. Adopted – 1.13.2020 Chapter 7 Public Utilities and Infrastructure Dover 2019 Comprehensive Plan Chapter 7 PUBLIC UTILITIES and INFRASTRUCTURE PLAN P U B L I C U T IL I T IES AN D IN F R AS T RU C T U R E Water, wastewater, and energy and their infrastructure play important roles in keeping the public healthy. Water quality requirements like source protection and chlorination exist to prevent contamination of our water supplies and ensure its quality for drinking and other uses. Energy powers our homes, workplaces, schools, hospitals and other critical facilities keeping us safe and healthy. However, certain energy sources (i.e. fossil fuels, coal) also contribute significantly to air pollution and other environmental impacts that have a negative impact on public health. The City of Dover is a full-service utility provider offering electric, water and wastewater services within and beyond the City limits. Additionally, the City owns and manages a storm sewer system that collects and conveys stormwater runoff from City streets to surface waters or stormwater management facilities. WATER UTILITY The City of Dover’s water system began operations in 1882 with an initial system of 13,000 linear feet of pipe and one well. Since its inception, the water utility has grown to include more than 226 miles of pipe and twenty-one (21) wells. Like other areas of Delaware south of the Chesapeake and Delaware Canal, the City of Dover relies entirely on groundwater for its water supply. The City is a regional water supplier, supplying water to customers within and beyond the City limits. The City’s system includes interconnection with neighboring systems as well. Currently, the City’s water utility includes approximately 13,000 metered connections. In addition to the metered connections, the City’s water system provides fire protection citywide through a system of fire hydrants. The water system operates as an enterprise fund with operation, maintenance and capital costs supported through user fees. The City of Dover’s water system is supplied by 15 deep wells and 6 shallow wells drawing potable water from three aquifers. The deep wells draw from the Cheswold aquifer and Piney Point aquifer, while the shallow wells draw from the Columbia aquifer. These wells draw an average of 4.7 million gallons of water each day. During summer months, water usage has peaked as high as 9 million gallons per day. The Department of Natural Resources and Environmental Control (DNREC) has permitted the City to draw as many as 11.043 million gallons of water per day from 2019 Comprehensive Plan Adopted 1.13.2020 Page 7 - 1 147

Paj 148

Item 7. Adopted -1.13.2020 Chapter 7 Public Utilities and Infrastructure Dover 2019 Comprehensive Plan Managing Inflow and Infiltration Inflow of stormwater and infiltration of groundwater into the City’s wastewater collection and transmission system has become an issue as the City’s sewer infrastructure ages. Cracks in the sanitary sewer pipes allow for both stormwater and groundwater to infiltrate. Additionally, in older areas of the City, many sump pump systems and rain gutters discharge directly to the sanitary sewer system. This additional flow places significant stress on Kent County’s wastewater treatment system by increasing the City’s flow to the wastewater treatment plant. It also costs the rate payers within the City of Dover in that the City must pay for all wastewater that is transmitted to the County for treatment, regardless of its source. In response to the issues of inflow and infiltration of stormwater and groundwater into the City’s sanitary sewer system, the City has developed a plan to identify sources of inflow and infiltration and to remove these sources from the system which includes replacing and/or relining aging sewer mains. Electricity and Energy Consumption The City of Dover is seeking to recognize a number of Green Energy Goals to reduce overall consumption where possible to better utilize existing capacity. Currently, there are several solar energy projects that have been authorized in the City’s service area including 337 residential solar installations with a capacity of 3.58 MW and 27 commercial installations with a capacity of 1.98 MW. A number of geothermal units have also been authorized by staff. The City is in the process of evaluating a number of alternative proposals for long-term power generation. Page 7 - 10 – 2019 Comprehensive Plan Adopted 1.13.2020 148

Paj 149

Item 7. Adopted – 1.13.2020 Chapter 7 Public Utilities and Infrastructure Dover 2019 Comprehensive Plan UTILITIES Goal 1: Proactively Maintain Existing Infrastructure and Expand Infrastructure When Beneficial Continue to place highest priority on maintaining existing utilities and community infrastructure, so that reliable service can continue to be provided to the existing community, and in the best interest of the community’s health and well-being. This includes the City’s Water, Wastewater (Sewer) and Electric Utilities which help maintain the daily functioning of the City. Recommendation 1: Update Utility Plans Regularly x Dover water, sewer and electric will have their long-range plans updated every ten to fifteen years and integrated into a Consolidated Utility Plan for the City of Dover. x Planned update to the Water Utility Plan by 2021, as it was last updated in 2006. x Planned update to the Wastewater Utility Plan by 2021, as it was last updated in 2009. x Planned update to the Electric Utility Plan by 2026, as it was last updated in 2016. x Planned update to the Stormwater Utility Plan in 10-year increments following implementation by City Council. Recommendation 2: Continue to Seek Mutually Beneficial Interconnections with Utility Systems x Analyze the ability of the City to sell water to Tidewater Utilities, the Camden-Wyoming Sewer and Water Authority and other neighboring water providers, for both domestic and fire protection use, within the current infrastructure capacity and allocation permit limits. Conversely, analyze the ability of neighboring water providers, in terms of both capacity and allocation, to allow the City to draw water in times of need. x Continue to work with Kent County with which the City’s wastewater system is interconnected to treat the City’s wastewater at the Kent County Regional Resource Recovery Facility in Frederica. x Continue to work with the City’s power supply and generation partners in managing the City’s energy production, as well as maintaining connections with the regional transmission and distribution system. Recommendation 3: Implement a Plan to Identify and Remove Sources of Inflow and Infiltration x Prepare projects to reline or replace old sewer mains to reduce and/or eliminate inflow and infiltration. x Work with property owners to remove catch basin, sump pump and other illicit connections to the sanitary sewer system that have been identified by field investigations or smoke testing. 2019 Comprehensive Plan Adopted 1.13.2020 Page 7 - 11 149

Paj 150

Item 7. Adopted -1.13.2020 Chapter 7 Public Utilities and Infrastructure Dover 2019 Comprehensive Plan Recommendation 4: Prepare and Implement Utility Systems Service Plans for future Annexation Areas x Study identified areas of potential future annexation into the City and prepare utility service plans to provide all essential City utilities and community services. Recommendation 5: Prepare a Long-term Strategy to Implement Capital Improvements that will be Most Impactful to the City and its Residents x Continue to identify key areas of Improvement for the City’s Water, Wastewater (Sewer), and Electric Utility Systems and layout a long-term strategy to implement projects to improve them. Goal 2: Enhance Infrastructure to Meet Community Needs Enhance public utilities and infrastructure where studies indicate that community services standards are not being met. Recommendation 6: Continue to Implement Plans to Improve Water Quality x Continue the commitment to implementing the water system improvements that will improve the water quality concerns and resolve “brown water” issues. x Continue to implement necessary improvements at City’s Water Treatment Plant and associated water system infrastructure. Recommendation 7: Continue to Implement Plans to Improve Wastewater Systems x Continue to implement the City’s long-term Capital Improvements Plan by investing in wastewater system facilities like new Pump Stations, Force Mains and Collection Systems. Recommendation 8: Identify and Pursue Options for Long-term, Reliable, Cost Competitive, and Environmentally Prudent Electricity for our Customers x Identify ways the City of Dover Electric Department can improve management of Electric infrastructure including long-term supply and capacity. x Continue to implement the City’s long-term Capital Improvements Plan with things like Substation Improvements, Transmission System Upgrades, Distribution System Upgrades, and Generation/Production Facility Improvements. x Continue to implement Green Energy Goals including utilizing energy sources like Solar. This will help reduce overall consumption where possible, allowing us to more efficiently utilize existing capacity. Recommendation 9: Ensure the City has the Infrastructure and Capacity to Accommodate Evolving Technologies x Ensure that the City has the capacity to accommodate the demand for new technologies like at-home and public charging stations and to anticipate the growing use of new modes of transportation like electric cars. This should be done in a manner that mitigates the impact on the electric distribution system. x Ensure that the City has a plan/policy in place to address and accommodate the infrastructure needed for new communication technology like 5G telecommunications. Page 7 - 12 – 2019 Comprehensive Plan Adopted 1.13.2020 150

Paj 151

Item 7. Adopted – 1.13.2020 Chapter 9 Transportation Plan Dover 2019 Comprehensive Plan COMPLETED AND PLANNED PROJECTS Since 2008 there have been a number of significant transportation improvements in Dover that have served to implement the Comprehensive Plan. Likewise, a number of studies have been completed that have furthered the goals of the Plan. These accomplishments are summarized in the “Completed Projects” section below. Completed Projects The following improvements have been accomplished in Dover or for specific areas within the City since 2008: x Constructed the new Dover Transit Center x Constructed POW-MIA Parkway (formerly known as the West Dover Connector) x Improved the intersection of West Street and North Street x Reconstructed North Street east of the railroad x Developed the 2015 Division Street/Forest Street Dover Capital Gateway Plan and Design Book x Implemented portions of the Delaware Route 8 Concept Plan and Operations Study x Adopted the 2015 Bicycle Plan and 2015 Pedestrian Plan x Installed sidewalks and pedestrian crossings along portions of Route 13 x Completed the key segments of the Senator Bikeway, Capital Trail and other bike and pedestrian plans x Implemented sidewalk and pedestrian crossing (HAWK signal) on Forrest Avenue for Dover High School Prioritized Projects Each year the City is requested to provide a list of transportation improvements to the Secretary of Transportation and the Dover/Kent County MPO that it wishes to see considered by these bodies in developing the DelDOT Project Prioritization Process and the MPO’s Transportation Improvement Program. Not all of the City’s recommendations are ultimately included in these documents nor do their priority necessarily match. In Fall 2019, the City of Dover City Council prioritized (dated September 24, 2019) a series of projects for inclusion into the State of Delaware’s six-year Capital Transportation Program. This prioritization was later revised by City Council in early December 2019. The following listing is the series of transportation improvement projects prioritized by City Council as of December 9, 2019: Garrison Oak Connector Road Garrison Oak Business and Technology Center (GOBTC) is a 385-acre tract zoned IPM-2 (Industrial Park Manufacturing Zone – Business and Technology Center) and is the only site in the City to be zoned as such. It has been identified by the City as an ideal location for large technology/green industry firms. Dover City Council desires that DelDOT provide a direct access to State Route 1 via a connector road to White Oak Road. While the State discourages growth east of State Route 1, this tract is acknowledged by both the City of Dover and the State of Delaware as the only large-scale developable land east of State Route 1 in the City of Dover. Page 9 - 16 – 2019 Comprehensive Plan Adopted 1.13.2020 151

Paj 152

Item 7. Adopted – 1.13.2020 Chapter 10 Economic Development Plan Dover 2019 Comprehensive Plan annual Firefly Music Festival, bring a significant number of visitors and tourism dollars into Dover and the State of Delaware In addition to these major commercial firms, several larger retail establishments make their home along the US Route 13 commercial corridor including Sam’s Club, Home Goods, Best Buy, Burlington, Kohl’s, Target, and other retail leaders, and auto dealerships. In addition, large-scale hardware and home improvement warehouse stores are represented including Lowe’s and Home Depot. The corridor also hosts dozens of restaurants as well as a diverse mix of specialty businesses. Several older commercial sites are undergoing redevelopment into attractive groups of retail spaces indicating the fundamental strength of this corridor. The City supports these initiatives. A second commercial corridor has become increasingly defined in Dover along Route 8 (Forest Street and Forrest Avenue) in the western section of the City. This commercial area hosts a mixture of shopping complexes, supermarkets, and neighborhood businesses that provide specialty services and products that draw consumers from the City and immediate area. Implementation of the Corridor Overlay Zone, a zoning overlay adopted in the early 1990s, has altered the appearance of the Route 8 commercial corridor by keeping the buildings closer to the road to maintain the small town, pedestrian accessible atmosphere, rather than the conventional commercial strip. Recent development along this corridor has included the new Dover High School and multi-family residential units. In 2005, Eden Hill Farm was initiated as a Traditional Neighborhood Design (TND) consisting of a Residential District, a Professional Office, Medical & Financial district, and a Neighborhood Commercial District with a focus on emerging medical and retail sectors. The Eden Hill Farm TND is being developed in accordance with a General Overall Master Plan and Comprehensive Design Standards Manual (Pattern Book) to create a unique mixed neighborhood. The Eden Hill Medical Center opened to the public in fall 2008 and has experienced expansion with the adjacent Center at Eden Hill, a state-of-the art rehabilitation facility. Nearby, in the Neighborhood Commercial District is a medical office facility operated by Nemours DuPont Pediatrics. Construction of the first housing units in the residential portion of Eden Hill also began in Fall 2008 and currently consists of 83 duplexes and townhouses. The economic downturn in 2008 stalled much of the residential and commercial construction, and recovery has been slow, but interest in both commercial and residential uses has now resumed. Garrison Oak Technical Park (now Garrison Oak Business and Technology Center) The Garrison Oak Tract was purchased by the City, with funding from the State, in 1999 and zoned as IPM-2 (Industrial Park Manufacturing Zone – Business and Technology Center). The site was funded through the State’s FY 2000 Bond Bill, which included epilogue language specifying that the site be used as a “high technology industrial park.” Its location on White Oak Road with potential access to State Route 1 has been identified by Dover and the State as a “potential location to promote economic activity.” Recently renamed as the Garrison Oak Business and Technology Center (GOBTC), this business park encompasses nearly 400 acres of land. Garrison Oak is an ideal location for large technological/green industry firms that require lot sizes of over 10 acres. The City has taken actions to make the site “shovel-ready” including the creation of a Subdivision Plan, road Page 10 - 6 – 2019 Comprehensive Plan Adopted 1.13.2020 152

Paj 153

Item 7. Adopted – 1.13.2020 Chapter 10 Economic Development Plan Dover 2019 Comprehensive Plan improvements within the site, and installation of infrastructure improvements to bring basic utilities to the site parcels. It is estimated that, once developed, the site would generate approximately 1,900 permanent jobs. GOBTC is currently home to the Dover Sun Park (solar facility), Garrison Energy Center’s 309-megawatt electric generation facility, Uzin Utz (flooring technology), and Advantech /Protective Services (a security systems provider). Civil Air Terminal and Kent County Aeropark Two facilities adjacent to Dover Air Force Base (DAFB) offer an unusual opportunity to develop an aviation and aeronautics focused employment center. The Civil Air Terminal (CAT) is located within the City limits and directly abuts DAFB. The Kent County Aeropark lies just west of the CAT. DelDOT owns the existing CAT and leases it to the Delaware River and Bay Authority for operations. The operations are sanctioned and governed by a Joint Use Agreement with the United States Air Force (USAF); that agreement is in negotiations to extend it for another 50 years. At present, the primary use of the CAT is to service occasional civilian charter aircraft and NASCAR race related aircraft and passenger services for the twice-yearly races. The existing Civil Air Terminal site consists of twenty acres including an 870 ft. x 325 ft. aircraft parking apron, a single taxiway connecting to the DAFB Taxiway B, and a 1,650+/- SF single story terminal with an accessory building, parking and fuel storage. In the Kent County Aeropark, immediately next to the Civil Air Terminal, are 13.2 undeveloped acres of a larger 117 +/- acre business park owned and developed by Kent County. The CAT and the four undeveloped parcels of the KCAP together comprise 33.3 acres. These are proposed to be to be rezoned as part of a comprehensive rezoning process to Industrial Park Manufacturing Zone - IPM3 (Industrial Aviation and Aeronautics Center) for industrial uses associated with aviation and aeronautics. The combined site is part of a County-designated employment center and will be marketed for aircraft maintenance, repair and operations; cargo/distribution terminal; aviation training; recreational aircraft terminal; aircraft manufacturing and civilian air cargo carrier temporary parking. The site will be marketed as the Central Delaware Aviation Complex to reflect its new focus. CONTRIBTING ECONOMIC COMPONENTS Tourism Industry Since the 2003 and 2008 Comprehensive Plans, the City has seen significant growth in the hotel sector with 22 hotels now within City limits. This sector is poised for continued growth due in part to the construction of the DE Turf, a multi-court field sports facility located south of Dover near Frederica which opened in 2017. DE Turf will bring considerable interest in accommodations, restaurants and other facilities to serve these visitors as it hosts numerous large tournaments. This contributes considerably to Dover’s economic stability and identity. Historic, cultural and natural resources such as the City's Historic District, parks, waterways and open space, and museums draw thousands of visitors yearly. The City continues to serve as a central location in Delaware that draws tourist and tourism dollars from both the region and nation. 2019 Comprehensive Plan Adopted 1.13.2020 Page 10 - 7 153

Paj 154

Item 7. Adopted – 1.13.2020 Chapter 10 Economic Development Plan Dover 2019 Comprehensive Plan x Downtown Dover Revitalization x Marketing Garrison Oak x Addressing and designating priority Industrial/Commercial Zones x Promoting Green Technology x Improving infrastructure, attractions, and events to increase tourism x Diversifying Dover’s economy by recruiting new industries that use a skilled work force in addition to adding to the current workforce x Strategic marketing to position Dover as a meetings and leisure travel destination x Retaining current employment base and assisting existing businesses and industry in become more successful x Strengthening economic development partnerships. x Improving general economic conditions (jobs, income, access, etc.) x Promoting healthcare as a major component of the economy x Recognizing the role of higher education to Dover’s economy x Creation of more skilled labor and trade jobs x Promoting tourism Since 2008, several initiatives have been undertaken to strengthen Dover’s economy and focus on growth opportunities, both Downtown and throughout the community. These are described below. Creation of the Downtown Dover Par tnership (DDP) Following the Dover: Downtown Economic Enhancement Strategy 2006 study, a consolidated organization called the Downtown Dover Partnership, (DDP) was established. The Partnership provides stronger leadership and better coordination of activities related to downtown revitalization. Working closely with the City and other Downtown partners, the DDP has focused attention on safety, parking, aesthetics, marketing and reducing vacancy. The DDP’s mission statement reads: “Promote the public welfare of the residents of the City of Dover, Delaware by promoting and furthering in any way, the development of the economic, cultural, and historic resources of the downtown area of the City of Dover, and to provide for the residents, to the extent that the common good and general welfare of the community is served.” The Partnership’s goal is to improve the opportunities for job creation, broaden the tax base through the development of the commercial and residential potential of the Central Dover area, and to maintain and restore the historic architectural and community qualities of the Downtown area consistent with the goals of the National Main Street Program. Restoring Central Dover Plan for the Downtown – 2013 (RCD Plan) The most thorough and recent planning initiative for the Downtown is represented by the 2013 Restoring Central Dover Plan. This comprehensive, community redevelopment effort was led by the National Council on Agricultural Life and Labor (NCALL) with strong support from the CenDel Foundation/Greater Kent Committee, the Dover Interfaith Mission for Housing, and the City of Dover. Intended to address the high-priority needs of low-income Central Dover residents with the goal of achieving long-term benefits by way of affordable housing, neighborhood safety and desirability, opportunities for economic growth, and essential services for children and families, the Restoring Central Dover Plan focused on incremental strategies founded on the idea that revitalization is about reinvesting in both people and place. Its goals were to: bring resources Page 10 - 14 – 2019 Comprehensive Plan Adopted 1.13.2020 154

Paj 155

Item 7. Adopted – 1.13.2020 Chapter 10 Economic Development Plan Dover 2019 Comprehensive Plan Goal 4: Ensure that Land Development, Zoning, Infrastructure and Other Development Requirements Encourage the Economic Development and Uses Desired Sound economic development and redevelopment is a balance between business opportunities and those regulations and processes designed to promote safe, well-designed, well-planned communities. The intent is to strike that balance between the proper exercise of public policy and a sustainable and viable economy. Recommendation 10: Review and Modify Regulations to ensure that Desired Uses Are Encouraged x Be flexible with contemporary zoning provisions that are responsive to emerging technologies and emerging business opportunities and activities, especially in the health care, arts and entertainment, and tourism sectors. x Implement appropriate zoning and other provisions that support development and expansion of targeted businesses, ensure the appropriateness of uses within respective zones, promote sustainability, encourage balanced growth, promote small businesses and startups, and ensure responsiveness to emerging economic and societal trends. x Update provisions addressing the growing variety and complexity of home occupations and accessory business activities in residential areas as the line defining traditional work evolves. x Actively pursue development of ordinances, policies and strategies to address blight, vacancy, abandonment, environmental contamination, and underutilization of business sites and facilities throughout the City. Goal 5: Actively market the Garrison Oak Business and Technology Center (GOBTC) Garrison Oak Business and Technology Center (GOBTC) is a City-developed business-ready facility in the City well-suited for larger and technology focused enterprises to help balance the City’s options for economic development and job creation. Capitalize on the GOBTC’s broad appeal to a larger universe of potential business activities consistent with the original intent of the facility and with the IPM2 zoning district. Recommendation 11: Develop a Strategic Marketing Plan for Garrison Oak (GOBTC) x Work with the Kent Economic Partnership and the State to effectively market the Garrison Oak Business and Technology Center. x Urge DelDOT and the Dover/Kent MPO to undertake planning and design for a dedicated connector from State Route 1 to the Center to improve access and marketability. x Explore the potential of the Garrison Oak Business and Technology Center for designation as a foreign trade zone. 2019 Comprehensive Plan Adopted 1.13.2020 Page 10 - 25 155

Paj 156

Item 7. Adopted – 1.13.2020 Chapter 12 Land Development Plan Dover 2019 Comprehensive Plan transportation infrastructure and mass transit services. Areas identified as Medium Density Residential can be looked at as potential receiving areas under a transfer of development rights program. Areas in the northern portion of the City are appropriate for Residential Medium Density development. North Side Neighborhood: Residential Medium Density The northwestern residential area of City includes the area that is to the north of College Road. This area consists of primarily Medium Density Residential developments such as Emerald Point, The Meadows and Mill Creek. There are also plotted subdivisions that have yet to start construction. Maidstone, Stonebrook East Planned Neighborhood District (PND), and Stonebrook West Planned Neighborhood District (PND) were approved by Planning Commission in 2005 and 2007 to construct a variety of mixed of housing types. White Oak Road Area: Residential Medium Density The Land Development Plan recommends that an area east of State Route 1 on White Oak Road be developed as Residential Medium Density. Bay Village who owns this property zoned RM-2 (Residential Medium Density Zone) could potentially develop it in an environmentally sustainable manner to provide workforce quality housing. While previously there was concern that development of this area could be a “domino” leading to additional development of land east of State Route 1, the State’s purchase of development rights in the area has reduced this concern. Additionally, the site’s location across from Garrison Oak Business and Technology Center makes it a good location for workforce housing. If there is residential development on the Lands of Bay Village, the City shall ensure that the development of the Bay Village site proceeds as a master planned community with transit access and bicycle and pedestrian amenities both within the site and connecting with Garrison Oak Business and Technology Center and other areas to the west. Additionally, the City must ensure that the viability of Garrison Oak Business and Technology Center is protected by requiring that the phasing and design of development on the site minimizes any potential conflicts between the residential and industrial uses and include buffering from the industrial area. West Side Neighborhood: Residential Medium Density Residential Medium Density development on the West Side tends to be located to the periphery of the area where both existing development, ongoing development and vacant lands are found. These areas are buffered by older residential areas and public/institutional uses but could be impacted by traffic and circulation concerns driven by commercial activities along the two major roadways, Route 8/Forest Avenue and McKee/Scarborough Road. Existing mix of housing types such as in the Village of Westover Planned Neighborhood Design (PND) and Village of Cannon Mill Planned Neighborhood Design (PND) are nearing the end of construction in those developments. A newer development, Chestnut Grove Farms has started construction and will build a variety of single-family detached homes, duplexes, and townhouses. East Dover Neighborhood: Residential Medium Density The East Dover Neighborhood essentially consists of developed in older established developments such as Towne Point, White Oak Farms, Baytree, Edgehill, and Schoolview. Recent development 2019 Comprehensive Plan Adopted 1.13.2020 Page 12 - 5 156

Paj 157

Item 7. Adopted – 1.13.2020 Chapter 12 Land Development Plan Dover 2019 Comprehensive Plan aspirations and expectations of its industrial and manufacturing community to support the vitality of these precious resources. 2. A healthy and well-rounded local economy will depend upon diversity in business and employment opportunities. 3. Opportunities exist to build on Dover’s regional proximity for warehousing and distribution and its access to Dover Air Force Base (DAFB) for expansion of civilian air transportation and aviation related manufacturing, service and repair functions. Goal: Employment Centers Create a more vibrant, growing economy with a broader range of job opportunities through collaborative efforts to market the region, identify potential targets, and respond to opportunities to foster an increase in office and industrial development in appropriate and designated areas. Policies: Employment Centers 1. Protect existing industrial, office park and manufacturing establishments from encroachment by incompatible land uses which could result in nuisance complaints, hazardous situations, and human conflict. 2. Provide sufficient land area for industrial purposes to enable the expansion of existing industries, the establishments of new facilities, and revitalization of underutilized older industrial sites. 3. Provide for a variety of office park and industrial development opportunities through the designation of areas for small, medium and large establishments within planned industrial parks. 4. Promote alternative modes of accessibility including pedestrian and bicycle facilities, bus shelters and transit stops, and provide incentives for car and van pooling of employees. 5. Create flexible and contemporary industrial zoning provisions that reflect emerging trends in uses, facilities, and business opportunities to meet future needs. Recommendations: Employment Centers The City is committed to fostering a strong, vibrant, and balanced local economy built on existing and new business locations. This initiative requires close coordination with state and county economic development entities. It also requires continuous attention to the needs of existing businesses, efforts to promote a skilled workforce, a comprehensive marketing and promotional strategy, and land use and development regulations that are efficient and contemporary. The Comprehensive Plan designates areas throughout the City where job growth and opportunities are encouraged. Plan Chapter 10 – Economic Development lays out a set of goals and actions designed to reinforce this commitment. 2019 Comprehensive Plan Adopted 1.13.2020 Page 12 - 17 157

Paj 158

Item 7. Adopted – 1.13.2020 Chapter 12 Land Development Plan Dover 2019 Comprehensive Plan Office Parks The Land Development Plan designates specific tracts of land of various sizes for Office and Office Park land uses. Office Park development involves an integrated development of office buildings with shared entrances, driveways and parking. The majority of uses permitted within an Office Park are generally weekday professional office uses involving very little or no activity at night or on weekends. For this reason, the Office Park designation may be viewed as a transitional use category when situated between more intense commercial and industrial land uses and residential land uses. This designation usually involves the C-PO (Commercial/Professional Office Zone) zoning district. These areas are located throughout the City with established office concentrations in the Enterprise Business Park, along Silver Lake Boulevard, on College Park Drive, along Old Rudnick Lane, the Northgate Center, and elsewhere. Scattered office uses are also located along Saulsbury/McKee Road and within designated “Mixed Use” areas in the Eden Hill Farm Traditional Neighborhood Design (TND). Smaller scale areas for office parks are the Woodbrook complex on South Governors Avenue, office complexes along Walker Road, and areas along Route 8. Large Scale Industry The Land Development Plan designates all existing major industrial facilities and associated vacant lands for Industrial use. These properties include the manufacturing facilities of Kraft Heinz Foods, Proctor & Gamble, Edgewell Personal Products, PPG Industries, General Metalcraft and others. Industrial Parks Several planned industrial parks have been initiated since 1986 which offer industrial development potential. The Land Development Plan designates these sites for continued Industrial use. These sites include Kent County Aero Park/Air Cargo Terminal, Enterprise Business Park, College Business Park, and McKee Business Park. The City purchased and has developed the Garrison Oak Business and Technology Center (formerly the Garrison Oak Technical Park) in 1999-2000. It now houses a solar electric facility, an electric generating facility, a flooring products manufacturer, and a security firm with ten shovel ready lots remaining available. Planning is underway to extend the Joint Use Agreement with Dover Air Force Base to allow expansion of the Kent County Aero Park into a regional facility. The Central Delaware Aviation Complex will facilitate aviation uses including air cargo, aircraft maintenance and repair, and related uses as part of a newly designated “Employment Center.” DOVER AIR FORCE BASE Although Dover Air Force Base (DAFB) is within the City limits, as a land holding of the Federal government it is not subject to municipal regulation. In recognition of the strategic importance of DAFB with respect to the national interest, as well as the contributions of DAFB to the local economy and overall image of Dover, it is essential that the Comprehensive Plan support and protect the vital interests of Dover Air Force Base as an integral part of Dover. Page 12 - 18 – 2019 Comprehensive Plan Adopted 1.13.2020 158

Paj 159

Item 7. Adopted – 1.13.2020 Chapter 12 Land Development Plan Dover 2019 Comprehensive Plan Policies: Public Utilities 1. Cooperate with other public and private providers to ensure system efficiency and capacity. 2. Actively assess emerging trends, technologies and regulatory schemes as these might impact the operation of the City’s utilities. Recommendations: Public Utilities The Land Development Plan reflects the existing locations of Public Utilities and private utility facilities. These encompass water, sewer, and electric system components such as water towers, pump stations, and electric substations. Examples of private utility facilities include the Dover Solar Park and the Garrison Energy Center. No enlargement of the land use area associated with Public Utilities is proposed at this time. AGRICULTURAL LAND USES Just as was true in 2008, there are currently properties within the City limits that remain in active agricultural use. Some of these properties are zoned for residential or other uses and are being farmed for the time being until being converted to another land use. Other properties have the A (Agriculture Zone) which is a zone that specifically permits agricultural uses. Several properties in the Agriculture Zone are also enrolled in Agricultural Preservation Programs with the State of Delaware Department of Agriculture, indicating that the owners intend to continue farming at least for the five to ten-year duration of the program and potentially for a longer time. The bulk of the land zoned Agriculture is located east of State Route 1, south of Dover Air Force Base, and along Route 8 in the western portion of the City adjacent to the Cranberry Run development. Assumptions: Agricultural Land Uses 1. Many agricultural land uses, particularly those lands which the owners have chosen to place in Agricultural Preservation Programs, are likely to continue as a long-term component in the City’s land use mix. Agricultural lands in the State’s program define and limit the City’s growth, at least for as long as they are actively in the Preservation status. 2. Agricultural land uses are appropriate where they form logical transitions to larger tracts of farmland in the County, where they complement sensitive natural features, and where they can be economically viable while retaining open space in the City. 3. Higher density urban land uses, such as those anticipated in the City, are not always compatible with active agricultural operations. Consideration will have to be given to proper buffering and other measures to mitigate conflicts between agricultural and other land uses. 4. With growing support for farm fresh and “farm-to-table” programs, the nature of agriculture will continue to evolve. Specialty crops and new growing techniques will make agricultural activities in the urban area increasingly challenging from both land use and regulatory aspects. 2019 Comprehensive Plan Adopted 1.13.2020 Page 12 - 21 159

Paj 160

Item 7. Adopted – 1.13.2020 Chapter 13 Growth and Annexation Plan Dover 2019 Comprehensive Plan agricultural use and in most instances part of an agricultural land preservation program. However, should their agricultural preservation status change their potential development adjacent to the City’s boundaries might raise issues of the efficient provision of services and infrastructure, transportation concerns, and protection of natural resources. If developed, the City would like to be notified by the Town of Wyoming or Kent County so that the City can work with the relevant jurisdiction to ensure that land planning includes interconnections with areas that may ultimately develop in the City of Dover. CLASSIFICATION OF POTENTIAL ANNEXATION LANDS Map 13-2: Potential Land Use for Annexation Areas shows the City’s position on the land use classifications appropriate for lands within the Category 1 and Category 2 Annexation Areas. The zoning classifications considered for each land use category (classification) are identified in Table 12-1: Land Use and Zoning Matrix. Map 13-2 identifies following areas for Residential Medium Density land use category if annexed into the City: the Papen Farm east of Wyoming Mill Road, the Kesselring Farm south of Webbs Lane, the enclave area along Nixon Lane and Acorn Lane, and the area north of Denney’s Road. The plan identifies areas to the west of the City including Fox Hall Drive, Mifflin Road, and the Artis Drive areas and the Rodney Village area as the Residential Low Density land use category. This designation is also recommended in the area east of State Route 1 along Fox Road (currently developed residential lots). The map identifies the large enclave area north of the Dover Mall (which is currently a manufactured home park and other commercial and residential areas) as Mixed Use. If this area were to annex and redevelop, it is an ideal opportunity for a master-planned mixed-use community. The large enclave area east of McKee Road and north of College Road has been identified as Mixed Use if annexed. This area is adjacent to other industrially zoned areas and is bisected by the railroad tracks but could support mixed residential and commercial uses as well. The area east of the railroad corridor is identified as Open Space and has recently become part of the Fork Branch Nature Preserve. There is a small enclave area along McKee Road north of College Road that has been identified as Office and Office Parks. Most of the remainder enclave areas that front on major road corridors have been designated as a Commercial land use category if annexed. Areas adjacent to Dover International Speedway lands east of State Route 1 are identified reflecting their existing uses; this includes the categories of Residential Low Density, Industrial, and Agricultural. The Category 3 and the Areas of Concern on the Potential Annexation Map (Map 13-1) do not have potential Land Use Categories identified on the associated Map 13-2. As such, if Annexation of lands in these areas is sought then a Comprehensive Plan Amendment would be required in order to designate Land Use prior to annexation. If specifically related to an area eligible for annexation (i.e. being contiguous to the City), then a Comprehensive Plan Amendment can be considered at any time. Page 13 - 8 – 2019 Comprehensive Plan Adopted 1.13.2020 160

Paj 161

Item 7. $GRSWHG² &KDSWHU,PSOHPHQWDWLRQ3ODQ 'RYHU&RPSUHKHQVLYH3ODQ Natural Resources and Environment x Continue to support native tree planting and landscaping programs and tree/natural area maintenance through the Development Advisory Committee and the Department of Public Works. x Share the FEMA floodplain maps and information which pertain to the City to ensure homeowners, businesses and developers have accurate information about flood risks through a variety of outreach methods i.e. workshops, website, etc. x &RQWLQXH WR XWLOL]H WKH NQRZOHGJH DQG H[SHUWLVH RI WKH 6LOYHU /DNH &RPPLVVLRQ DV DGYRFDWHVIRUWKH/DNHDGYLVRUVWRWKH&LW\&RXQFLORQPDWWHUVUHJDUGLQJWKH/DNHDQGDV OLDLVRQVEHWZHHQWKH&LW\WKHSXEOLFDQG'15(&UHJDUGLQJ/DNHPDQDJHPHQWLVVXHV x &RQWLQXH SXEOLF HGXFDWLRQ RXWUHDFK DQG SDUWLFLSDWLRQHQJDJHPHQW PHDVXUHV IRU ZDWHU TXDOLW\DQGUHODWHGDFWLYLWLHVLGHQWLILHGLQ'RYHU¶V0XQLFLSDO6HSDUDWH6WRUPZDWHU6\VWHP 06 SURJUDP Historic Preservation x &RQGXFW 3XEOLF 2XWUHDFK DQG (GXFDWLRQ RSSRUWXQLWLHV UHJDUGLQJ +LVWRULF 'LVWULFW SURJUDPV x &RQWLQXHSDUWLFLSDWLRQDVD&/* &HUWLILHG/RFDO*RYHUQPHQW  x 8WLOL]HNQRZOHGJHDQGH[SHUWLVHRI+LVWRULF'LVWULFW&RPPLVVLRQIRFXVHGRQSUHVHUYDWLRQ DQGSURWHFWLRQRIKLVWRULFUHVRXUFHV Utilities and Infrastructure x (GXFDWH WKH SXEOLF RQ IORRGSODLQ WRSLFV WKURXJK RXWUHDFK WR KRPHRZQHUV DQG UHVLGHQWV IRFXVLQJRQKHOSLQJUHVLGHQWVXQGHUVWDQGWKHLUIORRGULVNDQGZKDWWKH\FDQGRWRPLWLJDWH IORRGLQJLQWKH&LW\ x &RQWLQXHHQIRUFHPHQWRIIORRGSODLQUHJXODWLRQVDQGDVVRFLDWHGFRQVWUXFWLRQFRGHV x ,PSOHPHQWDSODQWR UHPRYHVRXUFHVRILQIORZDQGLQILOWUDWLRQLQWKH&LW\¶V:DVWHZDWHU 6\VWHPV x &RQWLQXH WR LPSOHPHQW *UHHQ (QHUJ\ *RDOV WR KHOS LPSURYH WKH HIIHFWLYHQHVV DQG HIILFLHQF\RIRXUUHVRXUFHPDQDJHPHQWV\VWHPVSDUWLFXODUO\ZLWKHOHFWULFLW\ x 3URDFWLYHO\ PDLQWDLQ DQG LPSURYH WKH &LW\¶V XWLOLW\ LQIUDVWUXFWXUH ZDWHU VHZHU VWRUPZDWHUDQGHOHFWULF  Community Services and Operations x Evaluate the levels of City Services as they pertain to police, fire, and emergency response times. Service levels should be maintained or exceed their current status as Dover grows in population and land size. x Continue to build a robust online presence and implement other outreach communication efforts for the City focusing on City initiatives, education on City ordinances, and promoting Dover as a desirable place to live, work, and play. x Ensure existing services and facilities at the Dover Public Library building are maintained and expanded to support the number of daily visitors it encounters. x IPSURYH WKH &LW\¶V FXVWRPHU VHUYLFH IXQFWLRQV VR WKDW PRUH W\SHV RI DSSOLFDWLRQV payments, and inquiries can be made online WKURXJKWKH&LW\¶VZHEVLWH or are made &RPSUHKHQVLYH3ODQ$GRSWHG3DJH3 161

Paj 162

Item 7. $GRSWHG² &KDSWHU,PSOHPHQWDWLRQ3ODQ 'RYHU&RPSUHKHQVLYH3ODQ Emergency Operations Planning x Continue to comply with the National Incident Management System (NIMS) through participating in appropriate staff training and holding drills to prepare for potential disasters. x Increase the staff training and education available to ensure all essential staff are trained in NIMS and familiar with the Dover Emergency Operations Plan (DEOP). Planning and Use of Lands and Buildings x 6XSSRUWWKHDGDSWLYHPL[HGUHXVHRIH[LVWLQJEXLOGLQJVWKURXJKRXWWKH&LW\ x &RQWLQXHWRHYDOXDWHDQGDGRSWWKHODWHVWYHUVLRQVRIWKH%XLOGLQJ&RGHVDQG)LUH&RGHV x ,QFUHDVH FRRUGLQDWLRQ ZLWK GHYHORSPHQW FRPPXQLW\ DQG GHVLJQ SURIHVVLRQDOV RQ &LW\¶V UHJXODWLRQV 6+2577(50,03/(0(17$7,21   7KH IROORZLQJ LV D OLVWLQJ RI SURMHFWV VWXGLHV FRGH UHYLVLRQV DQG RWKHU DFWLYLWLHV WKDW ZLOO EH LQLWLDWHGRUIRFXVHGRQGXULQJWKHWZR\HDUVLPPHGLDWHO\IROORZLQJ&RPSUHKHQVLYH3ODQDGRSWLRQ Projects Projects - Transportation x Update the ³$JUHHPHQW 5HJDUGLQJ 'RYHU 86 %D\ 5RDG &RUULGRU 7UDQVSRUWDWLRQ Improvement District´WRVHWERXQGDULHVtarget horizon year, and service standards. x Work with DelDOT and the Dover/Kent County MPO to develop a Transportation Improvement District for the Route 13/Bay Road Corridor in Dover. Projects ² Economic Development x ,PSOHPHQWDPDUNHWLQJSODQIRU*DUULVRQ2DN%XVLQHVVDQG7HFKQRORJ\&HQWHULQFOXGLQJ HVWDEOLVKLQJ D ZHE SUHVHQFH HQVXULQJ OLVWLQJ IRU HFRQRPLF GHYHORSPHQW LPSURYLQJ VLJQDJHDQGVLWHHQKDQFHPHQW Projects ² Downtown Revitalization x 'HYHORSDQGLPSOHPHQWD'RZQWRZQSDUNLQJSODQ x 3URPRWHWKHYLWDOLW\RIWKH'RZQWRZQ'HYHORSPHQW'LVWULFWE\GHYHORSLQJDVKDUHGYLVLRQ IRUWKH'RZQWRZQVWUDWHJLFDOO\DGGUHVVLQJFULPHYDFDQF\DQGEOLJKW x 'HYHORSUHYLVHGRUQHZLQFHQWLYHV x ,PSOHPHQWDQHLJKERUKRRGGHYHORSPHQWVWUDWHJ\IRUDGMDFHQWFRPPHUFLDODQGUHVLGHQWLDO DUHDV Projects - Community Services and Operations x 'HYHORS DQG LPSOHPHQW D JRYHUQPHQWFLYLF FRPSOH[ SODQ DGGUHVVLQJ QHHGHG &LW\ JRYHUQPHQWRIILFHVDQGIDFLOLWLHV &RPSUHKHQVLYH3ODQ$GRSWHG3DJH5 162

Paj 163

Item 7. $GRSWHG² &KDSWHU,PSOHPHQWDWLRQ3ODQ 'RYHU&RPSUHKHQVLYH3ODQ Other Activities Other Activities - Transportation x (QFRXUDJH'$57WRVKDUHWKH'RYHU7UDQVLW&HQWHUZLWKSULYDWHLQWHUFLW\EXVHV /21*7(50,03/(0(17$7,21 $1'%(<21' /RQJWHUPSURMHFWVDUHWKRVHWDVNVWKDWZKLOHLPSRUWDQWFRPSRQHQWVRIWKH3ODQZLOOEHXQGHUWDNHQ ODWHU LQ WKH SODQQLQJ SURFHVV 7KLV PD\ EH D IXQFWLRQ RI WLPLQJ UHVRXUFHV UHVHDUFK DQG GDWD UHTXLUHPHQWVDQGGHSHQGHQFHRQFRPSOHWLRQRISUHFHGLQJWDVNV6RPHLGHQWLILHGSURMHFWVVWXGLHV DQGDFWLYLWLHVPD\EHPXOWLSKDVHGLQLWLDWLYHVRURQJRLQJODUJHSURMHFWV Projects Projects ² Community Services and Operations x ,PSOHPHQWDSODQWR UHPRYHVRXUFHVRILQIORZDQGLQILOWUDWLRQLQWKH&LW\¶V:DVWHZDWHU 6\VWHPV x 2EWDLQ$FFUHGLWDWLRQZLWKWKH$PHULFDQ3XEOLF:RUNV$VVRFLDWLRQLQUHFRJQLWLRQRIKLJK VWDQGDUGVDQGSURIHVVLRQDOLVP Studies Studies ² Natural Resources and Environment x Proactively plan for the impact new technologies such as alternative fuels, online goods and services delivery, and self-driving cars will have on lifestyles and travel. Studies ² Utilities and Infrastructure x (QVXUHWKDWWKH&LW\¶V8WLOLW\3ODQVRIWKH'HSDUWPHQWRI3XEOLF:RUNVDQGWKH(OHFWULF 'HSDUWPHQWDUHNHSWXSWRGDWHQRWLQJWKDWWKH\QHHGWREHXSGDWHGHYHU\\HDUV Studies ² Economic Development x Address development opportunities for West Center City area including review and implementation of prior planning studies. Code Amendments x 5HJXODUO\ UHYLHZ DQG UHYLVH WKH =RQLQJ 2UGLQDQFH /DQG 6XEGLYLVLRQ 5HJXODWLRQV DQG 'RYHU&RGHRI2UGLQDQFHVWRHQGXUHWKDWWKH\UHIOHFWFXUUHQWFRQGLWLRQVDQGWUHQGVDUH HIILFLHQWWRDGPLQLVWHUDQGSURPRWHVRXQGODQGXVHDQGGHYHORSPHQWLQWKH&LW\ Other Activities Other Activities ² Natural Resources and Environment x ,PSURYH WKH &LW\¶V %LF\FOH DQG 3HGHVWULDQ QHWZRUNV LQ DFFRUGDQFH ZLWK WKH UHFRPPHQGDWLRQVRIWKH%LF\FOH3ODQDQG3HGHVWULDQ3ODQ &RPSUHKHQVLYH3ODQ$GRSWHG3DJH9 163

Paj 164

Item 7. $GRSWHG²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¶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²&RPSUHKHQVLYH3ODQ$GRSWHG 164

Paj 165

Item 7. . BA BA BA Y SI DE Y SI DE TeA SI D Y SITE DATA DR DR EXCELLENT RECHARGE E D 1. OWNERS OF RECORD: CALPINE MID-ATLANTIC DEVELOPMENT, LLC I I RI VE VE AREA VE N/F LeA 2 CHRISTY DRIVE, SUITE 302 WETLAND AREA CHADS FORD, PA 19317 JOSEPH MCDANIEL TeA SATTERFIELD, JR. E-40-0015 LC-00-058.00-01-37.00 ZONED: AR RO AD N CsA CsA LeA RO AD RO AD 3. ENGINEER / SURVEYOR: c/o WILLIAM FERGUSON, VP REGIONAL OPERATIONS - PH. 925 382-1316 BECKER MORGAN GROUP INC. 309 SOUTH GOVERNORS AVE. DOVER, DELAWARE 19904 K K K 302-734-7950 SITE OA SITE OA SITE OA TE KnA TE TE 4. PROPERTY ADDRESS: WHITE OAK ROAD - N 50 TeA NE °09' HI HI HI DOVER, DE 19901 TO 8 09" W W W A ARCH I T E C TURE 840.98' FS E 9 '1 N N N /M T CsA 5. TAX PARCEL NUMBERS: 4-00-05800-02-4800-00001 (CALPINE HOLDINGS 1 LLC) CU -W ENG I NE E R I NG °1 4-00-05800-02-4900-00001 (CALPINE HOLDINGS 1 LLC) NE 47 ' 685. 6. DEED REFERENCE : D.R. 6821 - 153 (CALPINE HOLDINGS) TO 35' Delaware N 4.53 RK TeA FS N/F 7. SITE AREA SUMMARY: PARCEL 4800-00001= 104.06 ± AC± TeA 309 South Governors Avenue 13 LUTHER D. & DONNA SHANK, III PARCEL 4900-00001= +144.83 ± AC± I-50-186, 1-50-188 TOTAL PROPERTY AREA= 248.39 AC± (AFTER CONSOLIDATION) Dover, DE 19904 TeA LC-00-058.00-01-38.00 PROJECT FENCED AREA= 135.40 AC± (5,898,393 S.F.) 302.734.7950 ZONED: AR "E PROJECT PANEL AREA= 91.4 AC± (3,983,348 S.F.) (36.7%) The Tower at STAR Campus S 51°01'37 100 Discovery Boulevard, Suite 102 8. ZONING CLASSIFICATION: AC - AGRICULTURAL CONSERVATION DISTRICT (KENT COUNTY) AR - AGRICULTURAL RESIDENTIAL DISTRICT (KENT COUNTY) Newark, DE 19713 IPM-2 - BUSINESS AND TECHNOLOGY CENTER (CITY OF DOVER) 302.369.3700 9. PROPERTY USE: PRESENT USE: AGRICULTURE Maryland "E KENT COUNTY TAX ASSESSMENT MAP KENT COUNTY SOIL SURVEY ON-SITE WETLANDS PROPOSED USE: UTILITY SOLAR FACILITY (PUBLIC UTILITY) 312 West Main Street, Suite 300 VICINITY MAP SOILS MAP WETLANDS MAP Salisbury, MD 21801 N 50°00'4 SCALE : 1" = 2,000' SCALE : 1" = 2,000' SCALE : 1" = 2,000' 10. SETBACKS: AC - AGRICULTURAL CONSERVATION DISTRICT (KENT COUNTY) FRONT YARD: 40 FEET / 75 FEET (MAJOR ROAD) 410.546.9100 SIDE YARD: 25 FEET MINIMUM, 60 FEET COMBINED North Carolina TRAFFIC GENERATION DIAGRAM ROAD TRAFFIC DATA : REAR YARD: 40 FEET 3333 Jaeckle Drive, Suite 120 0" W N/F "VEHICLES IN A.M. / P.M. PEAK HOUR" KCR - 66 (WHITE OAD ROAD) - SPEED LIMIT = 50 MPH AR - AGRICULTURAL RESIDENTIAL DISTRICT (KENT COUNTY) Wilmington, NC 28403 STANLEY C. MIKELL, JR. AADT = 637 Trips (from 2020 Deldot Traffic Summary) FRONT YARD: 100 FEET 910.341.7600 A.M. (P.M.) S-24-0241 10 YEAR PROJECTED AADT: 1.16 x 115 = 134 TRIPS SIDE YARD: 75 FEET LC-00-058.00-02-45.00 N 10 YEAR PROJECTED AADT + SITE ADT: 136 TRIPS REAR YARD: 75 FEET www.beckermorgan.com ZONED: AR DIRECTIONAL SPLIT: 50% / 50% 717.85' 68 PEAK HOUR : 16.22% = 22 TRIPS {Design Hourly Volume (DHV)} IPM-2 - BUSINESS AND TECHNOLOGY CENTER (CITY OF DOVER) FRONT YARD: 60 FEET WHITE OAK ROAD 8.47% TRUCKS: 12 PEAK HOUR TRUCKS: 16.22% = 2 TRIPS SIDE YARD: 40 FEET (100' ADJACENT TO RESIDENTIAL) SITE REAR YARD: 75 FEET WWW.beckermorgan.com SITE TRIPS GENERATED: 11. BULK STANDARDS: COVERAGE: 65% MAX IMPERVIOUS ENTRANCE N 40°18'2 A 0 (2) MINIMUM FRONTAGE: 100 FEET 3" E 2 (0) KCR - 66 TO ITE: NO ITE DEFINITION FOR THIS USE /M BUILDING HEIGHT: EQUAL TO DISTANCE OF THE NEAREST LOT LINE W FS -W (CALCULATIONS ARE ESTIMATES) F IP 7" NE NE 8'3 TOTAL SITE ADT = 4 TRIPS PER MONTH 1,021.49' TO 12. BUILDING: EXISTING BUILDINGS: 0 S.F. °0 FS A.M. PEAK HR. TRIPS = 2 (50% IN / 50% OUT) PR. BUILDING AREA: 0 S.F. 83 ' 965.95' N 7.35 1,415.28' RK W P.M. PEAK HR. TRIPS = 2 (50% IN / 50% OUT) TOTAL AT COMPLETION: 0 S.F. FS Z 68 17 TO 393.78' NT DIRECTIONAL DISTRIBUTION: MO 2 50% FROM WEST (2 TRIPS) (1 a.m. pk.) 13. UTILITIES: WATER - ON SITE NE F V. 38 50% TO WEST (2 TRIPS) (1 p.m. pk.) SEWER - ON SITE N/ ICE 8-0 0 6.0 0 AL -0 S 40 14. IMPERVIOUS AREA: EXISTING: +/- 3,000 S.F. (TO BE REMOVED) & WR 02-4 E. - 1 PROPOSED: +/- 4,000 S.F. (<0.01%) °11' R 133 .00 AP/ TE -0 58 : MAX ALLOWABLE: 1,356,545 S.F. (23%) 30 AL -024 0-0 NED B ECKER M ORGAN G ROUP ARCHITECTURE - ENGINEERING DOVER, DE SALISBURY, MD WILMINGTON, NC TOTAL AT COMPLETION: +/- 4,000 S.F. (<0.01%) P C-0 ZO L "E 15. WETLAND AREA: 3,725,003 S.F. (85.51 AC.) LANDS N/F 16. WOODLAND AREA: EXISTING WOODED WETLAND: 3,725,003 S.F. (85.51 AC.) CALPINE HOLDINGS, LLC EXISTING WOODED UPLAND: 146,866 S.F. (3.37 AC.) LC-00-058.00-02-49.00 DEED BOOK: 6821 PAGE: 153 TOTAL EXISTING WOODLAND: 3,871,869 S.F. (88.88 AC.) 144.33 ACRES ± 17. TREE PRESERVATION EXISTING WOODED AREA: 3,871,869 S.F. (88.88 AC.) AND PLANTING REQ.: WOODED UPLAND TO BE CLEARED: 0 S.F. (0.00 AC.) (0.00%) TOTAL WOODED REMAINING: 3,871,869 S.F. (88.88 AC.) TOTAL NON-WOODLAND PROJECT AREA: 5,898,024 S.F. = 5,898,024 S.F. / 3,000 = 1,966 = 1,966 TREES REQUIRED EXISTING TREES TO BE RETAINED: 0 N 49°51'0 PROPOSED TREES (ON-SITE): 1,966 813. 18. ROAD CLASSIFICATION: WHITE OAK ROAD - LOCAL ROAD - 50 M.P.H. 98' 19. KENT COUNTY GROWTH ZONE: PARCELS NOT WITHIN GROWTH ZONE FIP 8" W T 20. DelDOT TID: PARCELS OUTSIDE OF DELDOT TRANSPORTATION IMPROVEMENT DISTRICTS IS T -D OS 432.78' FP N 27°59'30" E 21. INVESTMENT LEVEL: PARCEL WITHIN LEVEL 4 INVESTMENT AREA "E S 63°05'33 22. PROPERTY LOCATION: LATITUDE N 39° 11' 36" GRS80 - NAD83 (2011) S 38°20'36" C LONGITUDE W 075° 29' 15" GRS80 - NAD83 (2011) W FIP FIR TO 287.23' 23. SURVEY DATUM: NGS MONUMENTS FS 228.54' NE 2,129.55' VERTICAL: NAVD 88 - GPS - NC1 HORIZONTAL: NAD 83 (2011) DSP - DEDO -COR N 53°50'41" W 164.04' 24. MONUMENTATION: 53 FOUND / XX SET S 49°52'09" E S 36°06'12" W FIP 25. SURVEY CLASSIFICATION: SUBURBAN SURVEY FIP 308.22' N 167.95' FIR N 39°45'06 26. AVERAGE SITE SLOPE: 0-1% F LANE C "E L V E R L E A 27. AREA WITHIN SWM: N/A N/F SI 28. SOLAR FIELD EQUIPMENT: ± 55,680 MODULES BRIAN C. & MARYELLEN C. CARBAUGH ± 98 INVERTERS (FINAL LOCATIONS TO BE DETERMINED) 50°29'33" D-303-22 29. NUMBER OF LOTS: EXISTING: 2 LC-00-058.00-02-47.00 PROPOSED: 1 ZONED: AR P.B. 63 / 82 FIP W 5/8/02 N/F WETLAND LANDS N/F AREA CITY OF DOVER CALPINE HOLDINGS, LLC D-327-136 FIP LC-00-058.00-02-49.00 V V LC-05-068.00-01-03.00 DEED BOOK: 6821 PAGE: 153 3,653.70' ZONED: IPM2 N 144.33 ACRES ± V V FIP 2 6 V V V V V V V °46 V V S 54°40'28" E 286.91' V V V V V V V '01 V V V N 42°41'18" E V V V 67.23' FIP-DIST "W V V V N/F JOSE E. & MARIA J. MENDEZ LC-00-059.03-01-01.00 D-494-190 V V V V ZONED: AR GENERAL NOTES : 71 N/F 8 V FIP HARMAN BROTHERS, LLC 1. TOPOGRAPHIC SURVEY DATA SHOWN HEREON WAS PREPARED BY BECKER MORGAN GROUP, DOVER, IN JUNE . .92 FIP D-383-322 2006. VERTICAL DATUM IS BASED ON NAVD 88. THE BOUNDARY LINES PORTRAYED HEREON HAVE BEEN ' V V LC-00-059.03-01-06.00 ZONED: AR ESTABLISHED BASED SOLEY ON PHYSICAL EVIDENCE DISCOVERED IN THE FIELD IN CONJUNCTION WITH DETERMINATIONS DERIVED FROM A SOURCE OF TITLE AND ADJACENT DEED RECORD INFORMATION. N S 53°45'08" E V FIP V V N/F WILLIAM H. WARE 2. THE BOUNDARY LINES PORTRAYED HEREON HAVE BEEN ESTABLISHED BASED SOLELY ON PHYSICAL EVIDENCE V R-47-0282 DISCOVERED IN THE FIELD, IN CONJUNCTION WITH DETERMINATIONS DERIVED FROM SOURCE OF TITLE AND 233.95' FIP FIP V V LC-00-059.03-01-11.00 ADJACENT DEED RECORD INFORMATION. V V V ZONED: AR V V N/F V 1819.38' 1339.84' V V V 3. PROPERTY SHOWN HEREON IS SUBJECT TO ANY RIGHT-OF-WAY, EASEMENTS, RESTRICTIONS, ETC. AS MAY BE SUNSHINE BUILDERS, INC. FIRC FIRC N/F SHOWN OR NOTED IN ANY RECORD, PUBLIC OR OTHERWISE, OR ANY REQUIREMENT OR REGULATION OF ANY V EXISTING 80' TAX W-34-0315 V V V ROBERT L. ANTHONY PUBLIC AGENCY. LC-00-058.00-02-70.00 V DITCH BUFFER D-658-0127 479.V53' FIR (SEE NOTES 4 AND 5) LC-00-059.03-01-12.00 PROJECT TITLE ZONED: MULT FC S 37°44'16" W C V N 36°28'54" E 483.99' ZONED: AR 4. NO PORTION OF THIS SITE IS AFFECTED BY THE HUNDRED YEAR FLOOD PLAIN BASED ON FIRM MAP #10001C0178j, N/F M SUNSHINE BUILDERS, INC. V 250.04' DEER STREET PANEL 178 OF 435, DATED MAY 2003, REVISED 7/7/14. W-34-0315 LC-00-058.00-02-69.00 N/F HAZEL M. VOSHEL PARCEL DEED LINE N/F HEATHER LEE GREENLY D-3021-0010 5. WETLANDS SHOWN HEREON WERE IDENTIFIED AND FIELD LOCATED BY ECT, DATED JULY 2021. CALPINE'S KENT 2,298.03' ZONED: AR LC-00-058.00-02-56.00 C-18-0340 N 35°13'39" E 531.93' FIRC LC-00-059.03-01-13.00 ZONED: AR 6. NO OBSERVABLE EVIDENCE OF SITE USE AS A CEMETERY, SOLID WASTE DUMP, SUMP OR SANITARY LANDFILL WHEN FIELD SURVEY WAS COMPLETED IN MARCH 2021. COUNTY SOLAR ZONED: AR FIRC ZONED AC RADIUS = 1176.13' LENGTH = 394.01' CH. BEARING = S 73°57'43" E 7. THE APPLICANT SHALL SUBMIT A RECLAMATION PLAN AND A DECOMMISSIONING SECURITY IN THE FORM OF ENERGY CENTER BONDS TO GUARANTEE THE AVAILABILITY OF FUNDS FOR SYSTEM REMOVAL PRIOR TO FINAL SITE PLAN CH. LENGTH = 392.17' APPROVAL. THE BOND AMOUNT SHOULD BE EQUIVALENT TO THE DECOMMISSIONING AND RECLAMATION COSTS TANGENT = 198.87' FOR THE ENTIRE PROJECT. THE SITE RECLAMATION PLAN SHALL DEFINE THE RECLAMATION, RE-VEGETATION, Δ = 19°11'41" RESTORATION, AND SOIL STABILIZATION PLANS FOR THE PROJECT AREA. THE DECOMMISSIONING AND RECLAMATION ACTIVITIES SHOULD INSURE EXPEDITIOUS RECLAMATION OF CONSTRUCTION AREAS AND THE RE-VEGETATION OF DISTURBED AREAS TO REESTABLISH THE INHERENT AGRICULTURAL VALUE OF THE LAND. . THIS SHOULD OCCUR WITHIN 12 MONTHS OF THE CLOSING OF THIS FACILITY. ZONED AR N/F JOHN M. & REBECCA 60 ) . 9) 676 CLENDANIEL M-29-0063 ZONED AC FT E R. T # LC-00-058.00-02-51.00 WHITE OAK ROAD 3" N 51°37'42" ZONED: AR 3'3 DOVER, DE 19901 (S. AC EXISTING WETLANDS LANDS N/F S8 3°3 W CALPINE HOLDINGS, LLC LITTLE CREEK HUNDRED 3°3 S8 LC-00-058.00-02-48.00 KENT COUNTY, DE TR DEED BOOK: 6821 PAGE: 153 3'3 E 104.07 ACRES ± LEGEND SHEET TITLE IV CON ITEM EXISTING PROPOSED ZONED AR C FIR DRLDOT SANITARY GRAVITY SEWER LINE, 10" S ZONED AC 6" W COVER SHEET ' EX. 10"S 1'5 SIZE & FLOW DIRECTION .50 N/F JOHN M. & REBECCA °4 ' 32 SANITARY SEWER FORCE MAIN, SIZE 12" F.M. 519 EX. 10" F.M. S 7.67 E & FLOW DIRECTION CLENDANIEL 30.5' ID (DE SANITARY SEWER MANHOLE (S.M.H.) W-32-102 27 LC-00-058.00-02-50.00 YS .W. SANITARY SEWER CLEANOUT ZONED: AR FIP-DIST ZONED AC 1518.29' WATER MAIN & SIZE EX. 10" W 12" W FIP FIP BA . R.O FIRE HYDRANT F.H. F.H. LOT 19 E FIP S 57°04'04" E 3" HILLDALE ROAD WATER VALVE (W.V.) OR METER (W.M.) FIP W.M. W.V. W.M. W.V. LOT 17 ZONED AC STORM DRAIN MANHOLE (S.D.M.H.) N/F LOT 15 JOHN M. & REBECCA FIR ZONED AR STORM DRAIN LINE (CMP OR RCP) CLENDANIEL FIRC C V-31-124 LOT 13 688 0 100 200 400 CATCH BASIN LC-00-058.00-02-50.01 ' ZONED: AR FIRC WETLAND CERTIFICATION 2014092-CERT-WETLAND UTILITY POLE W/ OVERHEAD SERVICE LOT 11 (TELEPHONE OR ELECTRIC OR BOTH) THIS PROPERTY, TAX MAPS # 4-00-05800-02-4800-00001 & 4-00-05800-02-4900-00001 HAVE BEEN EXAMINED BY ECT FOR FIP ZONED AC Do Not Explode - Select Scale FIRC THE PRESENCE OF SUBAQUEOUS LANDS AND STATE AND/OR FEDERALLY REGULATED WETLANDS AS ESTABLISHED UNDERGROUND ELECTRIC U.E. U.E. FIP LOT 9 BY THE REVIEWING AGENCIES IN THE FORM OF MANUALS, POLICIES AND PROCEDURES IN PLACE AT THE TIME THAT SCALE: 1" = 200' UNDERGROUND TELEPHONE U.T. U.T. THE INVESTIGATION WAS CONDUCTED. THE WETLAND INFORMATION CONTAINED IN THIS PLAN SET IS IN LOT 7 ACCORDANCE WITH THIS CRITERIA. UNDERGROUND GAS MAIN EX. 2" G 2" G ISSUE BLOCK FIP 605.64' N/A FIR PAVEMENT TO BE REMOVED LOT 4 679 LOT 5 FIP FIP V C CONCRETE CURB & GUTTER V V V V .66 SIGNATURE DATE T FIR V V V 69' ' CONCRETE SIDEWALK, SLAB / PAVING C V V IN FIP SIRC FIP 14 9' IMPERVIOUS SURFACED ROAD, DRIVE OR LOT PO 1923.63' S 33°05'00" W FA 580.84' FIR S 33°05'00" W 17 2' OWNERS CERTIFICATION FA INDIVIDUAL TREE OR BUSH N/A AD I I C 45' WE, CALPINE MID ATLANTIC LLC, HEREBY CERTIFY THAT WE ARE THE OWNER OF THE PROPERTY DESCRIBED AND EVERGREEN DECIDUOUS NG WHITE OAK ROAD (C.R. 66) FIP FC M- SHOWN ON THIS PLAN, THAT THE PLAN WAS MADE AT OUR DIRECTION, AND THAT WE ACKNOWLEDGE THE SAME TO BE WIRE FENCE X X X X X X RO S 37°12'00" W 42.5 FT. R.O.W. (DELDOT CONTRACT # 921) 22.5' DI OUR ACT AND DESIRE THE PLAN TO BE DEVELOPED AS SHOWN IN ACCORDANCE WITH ALL APPLICABLE LAWS AND CHAINLINK FENCE LO 298.38' S 38°44'00" W ST F REGULATIONS. N/ ALE N STOCKADE FENCE 595.55' RADIUS = 2269.50' LENGTH = 223.60' P D IO LL IS HI DIV 227 CH. BEARING = S 35°54'30" W . STRUCTURE (CONCRETE, WOOD, CH. LENGTH = 223.71' . . METAL, ETC.) B 1P . TANGENT = 111.99' SU .B. MARK DATE DESCRIPTION DRAINAGE DITCH OR SWALE Δ = 5°39'00" SIGNATURE DATE LAYER STATE: C-001 EMBANKMENT SIDESLOPES (DOWN) PROJECT NO.: 2021314.00 CONTOUR 49 55 ENGINEERS CERTIFICATION I, J. MICHAEL RIEMANN, P.E, HEREBY CERTIFY THAT I AM A REGISTERED ENGINEER IN THE STATE OF DELAWARE, THAT DATE: 02/03/2022 ELEVATION SPOT SHOT 43.55 25.50 T.C. 25.15 THE INFORMATION SHOWN HEREON HAS BEEN PREPARED UNDER MY SUPERVISION AND TO MY BEST KNOWLEDGE AND 25.00 B.C. BELIEF REPRESENTS GOOD ENGINEERING PRACTICES AS REQUIRED BY THE APPLICABLE LAWS OF THE STATE OF SCALE: 1" = 200' BENCH MARK N/A DELAWARE. PROPERTY OR RIGHT-OF-WAY LINE DRAWN BY: JNS PROJ. MGR.: JNS CENTERLINE SHEET LIGHT POLE CONSTRUCTION NOTE N/A J. MICHAEL RIEMANN P.E. NO. DATE C-001COPYRIGHT 2020 165 F:\AutoCAD\Projects\2021\2021314\DWG\2021314-SITE-C3D21-DE.dwg, Dec 14, 2022 - 1:03pm 2022-12-14

Tounen nan reyinyon sa a