Page 1
CITY OF DOVER, DELAWARE
PLANNING COMMISSION
Monday, April 19, 2021 at 7:00 PM
Virtual Meeting
AGENDA
Written comments are accepted via mail to City of Dover – Planning Commission, P.O. Box 475 Dover
DE 19903 and via email at CompPlan@dover.de.us.
VIRTUAL MEETING NOTICE
The Planning Commission Meeting for April 19, 2021 will be held only as a Virtual Meeting using
WebEx. Representatives of each Project Application will receive a specific invitation to attend this
meeting. Regular Planning Commission member participants will receive a specific invitation to attend
the meeting as a Panelist. The public is welcome to attend the Meeting using the Public Participation
Information given below.
PUBLIC PARTICIPATION INFORMATION
City of Dover Planning Commission Meeting of April 19, 2021
Dial: 1-408-418-9388
Event number/Access code: 129 886 1139
Event password: DoverPC
Event Address: http://bit.ly/PCMeeting041921
If you are new to WebEx get the app now at https://www.webex.com/ to be ready when the
meeting starts. For problems accessing the meeting, please call the Planning Office at (302) 736-
7196.
CALL TO ORDER
PLEDGE OF ALLEGIANCE
ROLL CALL
ADOPTION OF AGENDA
APPROVAL OF MINUTES
1. Adoption of Minutes of March 15, 2021
COMMUNICATIONS & REPORTS
1
Page 2
PLANNING COMMISSION - April 19, 2021 PAGE 2
Meeting Reminder: The next Planning Commission regular meeting date is Monday, May 17, 2021
at 5:30PM. Please note the earlier start time due to volume of agenda items including the
Comprehensive Rezoning 2021 Project and Comprehensive Plan Amendments 2021 Set #2.
Update on City Council Actions
Department of Planning & Inspections Updates
2. Implementation of 2019 Comprehensive Plan - New Revised Maps
Education and Training Opportunities
3. University of Delaware: Institute for Public Administration Training Sessions
OPENING REMARKS CONCERNING MEETING PROCEDURES FOR APPLICATIONS
OLD BUSINESS
Request Extension of Planning Commission Approval
4. S-19-07 - Retail Facility at 515 South DuPont Highway – Request for 1-year Extension of
Plan Approval granted by the Planning Commission in April 2019 for a Site Development
Plan Application to permit construction of a one-story 8,050 SF retail building and
accompanying site improvements. The site is currently vacant. The subject area is 0.91 +/-
acres located on the east side of South DuPont Highway south of Cowgill Street and north of
Public Safety Boulevard. The property is zoned C-4 (Highway Commercial Zone). The
owner of record is Kent Del Properties, LLC. Property Address: 515 South DuPont Highway.
Tax Parcel: ED-05-077.00-01-12.00-000. Council District 2.
Pending Development Application:
5. C-21-02 JJ’s Learning Experience 2 Child Day Care Center at 756 South Little Creek Road –
Continued Review for an Application for a Conditional Use to permit renovation of a 10,111
SF space in an existing one-story 33,143 SF building into a Child Day Care Center to serve
170 children. The property consists of a 2.39 acre+/- parcel and is located on the south side
of South Little Creek Road opposite Babb Drive. The property is zoned C-4 (Highway
Commercial Zone). The owner of record is Empire Medical, LLC and the applicant is JJ’s
Learning Experience 2. Location Address: 756 South Little Creek Road Suite 1. Tax Parcel:
ED-05-077.00-01-03.00-000. Council District 2. This Application had originally been
submitted for Review by the Planning Commission at their March 2021 meeting, however
Action was deferred pending further information being provided by the Applicant.
NEW APPLICATIONS
6. Z-21-03 Lands of Silver Linings Holding Corporation at 630 W. Division Street - Public
Hearing and Review for Recommendation to City Council on a rezoning application for a
parcel of land consisting of 1.0853 acres (47,275.3 SF +/-). The properties are zoned C-3
(Service Commercial Zone) subject to the COZ-1 (Corridor Overlay Zone). The proposed
zoning is C-2A (Limited Central Commercial Zone) subject to the COZ-1 (Corridor
Overlay Zone). The property is located on the south side of West Division Street and
2
Page 3
PLANNING COMMISSION - April 19, 2021 PAGE 3
opposite the intersection with Ridgely Street. The owner of record is Silver Linings Holding
Corporation c/o Tolano Anderson. Property Address: 630 W. Division Street. Tax Parcel:
ED-05-076.08-01-40.01-000. Council District 4. Ordinance #2021-07. This property was
the subject of Rezoning Application Z-20-03 that was unsuccessful in its rezoning request
for IO (Institutional and Office Zone) with COZ-1 in November-December 2020.
7. S-20-10 Bayhealth Staff Parking Lot Expansion at Scull Property (Revision of March 25,
2021) - Public Hearing and Review of a proposed Site Development Master Plan Application to
permit construction of 453 new parking spaces over the course of three phases for the
Bayhealth Medical Center Campus. This expands the existing parking from 227 spaces to a
total of 680 parking spaces on the Scull Property. Phase 1 proposes 251 new parking spaces;
Phase 2 proposes 72 new parking spaces; and Phase 3 proposes an additional 91 parking spaces
and a connection to S. State Street at the South Street intersection. The Plan shows the
demolition of existing buildings in each phase for a total of seven (7) buildings demolished
including the Scull Mansion to accommodate the increased volume of parking. The Revision
offers a proposal related to the Scull Mansion. The properties measure 11.43 acres +/- and are
located on the east side of S. State Street in the block between South Street and Scull Terrace.
The properties are zoned IO (Institutional and Office Zone) and subject to the SWPOZ (Source
Water Protection Overlay Zone). The owners of record are Bayhealth Medical Center, Inc. and
KGH Development Corp. The parcels are proposed to be consolidated before the project
begins. Property Addresses: 605 S. State Street, 625 S. State Street, 100 Scull Terrace, and 150
Scull Terrace. Tax Parcel Numbers: ED-05-077.13-01-49.00-000 and ED-05-077.13-01-51.00-
000. Council District 2. Waiver Requests: Elimination of Upright Curbing and the
Elimination/Relocation of Bicycle Parking. This Application was withdrawn by the applicant
from the October 2020 Meeting of the Planning Commission. A Revision submission dated
March 25, 2021 has been received for review.
NEW BUSINESS
ADJOURN
Posted Agenda: Friday, April 9, 2021
THE AGENDA ITEMS AS LISTED MAY NOT BE CONSIDERED IN SEQUENCE. PURSUANT TO
29 DEL. C. §10004(e)(2), THIS AGENDA IS SUBJECT TO CHANGE TO INCLUDE THE ADDITION
OR THE DELETION OF ITEMS, INCLUDING EXECUTIVE SESSIONS, WHICH ARISE AT THE
TIME OF THE MEETING
3
Page 4
Item 1.
CITY OF DOVER PLANNING COMMISSION
MARCH 15, 2021
The Meeting of the City of Dover Planning Commission was held on Monday, March 15, 2021
at 7:00 PM as a Virtual Meeting using the phone/videoconferencing system WebEx due to
Delaware’s Declaration of the State of Emergency for COVID-19. The Meeting Session was
conducted with Chair Mrs. Maucher presiding. Members present were Mr. Adams, Mr. Roach,
Mrs. Malone, Mr. Hartman, Mr. Baldwin, Mrs. Lord, Mrs. Welsh, Dr. Jones and Mrs. Maucher.
Staff members present were Mr. Dave Hugg, Mrs. Dawn Melson-Williams, Mr. Julian
Swierczek, Mrs. Samantha Bulkilvish, Mrs. Tracey Harvey, Mr. Jason Lyon and Mrs. Kristen
Mullaney. Also present were Ms. Shawanda Johnson, Mr. Jeff Speigleman, Mr. Doug Liberman,
Ms. Michelle Marinucci and Mr. Jonathan Street. Speaking from the public were Mr. Allan
Angel, Mr. Michael Petit de Mange, and Ms. Karen Vicks.
APPROVAL OF AGENDA
Mrs. Welsh moved to approve the Agenda tonight, seconded by Mr. Adams and the motion was
unanimously carried 9-0.
APPROVAL OF MEETING MINUTES OF FEBRUARY 16, 2021
Mrs. Welsh moved to approve the Planning Commission Meeting Minutes of February 16, 2021,
seconded by Mr. Adams and the motion was unanimously carried 9-0.
COMMUNICATIONS & REPORTS
Mr. Hugg stated that the next Planning Commission regular meeting is scheduled for Monday,
April 19, 2021 at 7:00PM.
Mr. Hugg provided an update on the regular City Council and various Committee meetings held
on February 22 & 23, 2021 and March 8 & 9, 2021.
Mr. Hugg stated that they are all generally coming back to work in the office; some people are
still working at home and part time in the office. The building is open for business; the lobby
only. They are taking applications and plans submissions in the lobby personally as opposed to
remotely or just in the vestibule. However, we are still conducting all of our meetings in a virtual
format; that includes Pre-Application meetings, site meetings, and the Planning Commission,
Board of Adjustment and Historic District Commission meetings.
OPENING REMARKS CONCERNING DEVELOPMENT APPLICATIONS
Mrs. Melson-Williams presented the audience information on policies and procedures for the
Virtual Meeting using the WebEx system.
OLD BUSINESS
1) Requests for Extensions of Planning Commission Approval: None
NEW APPLICATIONS
1
4
Page 5
Item 1.
CITY OF DOVER PLANNING COMMISSION March 15, 2021
C-21-02 JJ’s Learning Experience 2 Child Day Care Center at 756 South Little Creek Road -
Public Hearing and Review of an Application for Conditional Use to permit renovation of a
10,111 SF space in an existing one-story 33,143 SF building into a Child Day Care Center to
serve 170 children. The property consists of a 2.39 acre+/- parcel and is located on the south side
of South Little Creek Road opposite Babb Drive. The property is zoned C-4 (Highway
Commercial Zone). The owner of record is Empire Medical, LLC and the applicant is JJ’s
Learning Experience 2. Location Address: 756 South Little Creek Road Suite 1. Tax Parcel: ED-
05-077.00-01-03.00-000. Council District 2.
Representative: Ms. Shawanda Johnson, JJ’s Learning Experience; Mr. Jeff Spiegelman, Real
estate representative
Mrs. Harvey stated that the Conditional Use Site Plan Review is to permit the renovation of an
existing 10,000 SF space in an existing one-story 33,000 SF building into a Child Day Care
Center to serve 170 children and 19 adult staff. The building is located on the south side of South
Little Creek Road opposite of Babb Drive. The owner of record is Empire Medical, LLC and the
applicant is Ms. Shawanda Johnson. The property address is 756 South Little Creek Road. The
plan identifies an outdoor play area that will be fenced in on the south side of the building. There
are two areas of existing pavement to be utilized as parking lots for a total of 73 spaces on the
site. The property is zoned C-4 (Highway Commercial Zone) with the existing footprint of the
building not changing or enlarging. There is direct access to the site; one to the large parking lot
on the west side of the building and one to the proposed parking area on the east side of the
building. There are two entry ways and exits off of South Little Creek Road. These entrances
must be evaluated by DelDOT for any necessary improvements. Dumpsters for trash and
recycling collection are required for the property. The plan identifies the two dumpster locations
for the building with the concrete pad and enclosure. There is an existing sidewalk and curbing
along South Little Creek Road. There is currently no sidewalk on South Little Creek Road
serving as direct access to this site. For the Day Care Center on the east side of the building, the
entire parking lot is paved. Access is proposed to the building with the construction of steps and
a ramp on the east side of the building. The Planning Commission may prescribe appropriate
conditions for establishment of the use.
Mr. Hartman questioned the lighting for the building on the east side. Since the Day Care will be
open until 7PM some nights, has there been any consideration of the lighting requirements on
that side of the building? Responding to Mr. Hartman, Mrs. Melson-Williams stated that any
commercial establishment should have lighting that lights the parking lot areas. She is not sure if
there are any wall-mounted fixtures on that side of the building. If there is not, then there may
need to be freestanding lighting for that side but that is something that they can certainly
confirm. There may be street lighting along South Little Creek Road in that area that may assist
in lighting some of the property.
Mr. Hartman stated that they are all concerned with the safety of the children and he is sure that
Ms. Johnson is concerned with that as well. The parking lot appears to be pretty tight so he was
thinking that lighting should be addressed by the applicant for the safety of the children. He has
another question regarding handicapped parking which is not on the east side of the building at
2
5
Page 6
Item 1.
CITY OF DOVER PLANNING COMMISSION March 15, 2021
all. Why is there no handicapped accessible parking near the ramp on the east side of the
building? Responding to Mr. Hartman, Ms. Johnson stated that she does not believe that there is
any lighting located next to the building but they do have plans to have some freestanding
lighting out there as well as in the parking area. That is a requirement from the Office of Child
Care Licensing as well; from the time that you are open and during evening hours to have it well
lit. As far as the handicapped space parking, she does know that they have a ramp but she does
not see the handicapped parking available on that side but that is something that she can address
as well with the architect.
Mr. Hartman further questioned the position of the dumpster. Again, that is a tight area and when
they are emptying that dumpster, it appears that they are backing up towards the entrance to the
Child Care Center and he is concerned about the safety of the children when that occurs.
Responding to Mr. Hartman, Ms. Johnson stated that normally during the dumpster hours as far
as emptying, if children are not there except for when parents are dropping off. They are only
really going to be out there in the playground area which has to be childproof locked on both
sides. We have to have two exits but they also have to be childproofed. Really the only issue
would be dropping off and picking up which they should be supervised by their parents at that
time.
Mrs. Melson-Williams stated that in this case, the trash collection and recycling collection would
be a private hauler so they would have to work with the property owner or tenant about pickup
options. Depending on if the truck needs to access on the front on or a side, there certainly may
be an opportunity to reposition that. You could request that they look at doing so.
Mr. Hartman stated that he would request Ms. Johnson to work with either the Planning Office or
the private collector to make sure that the children who are entering or exiting that entrance are
not put in danger by the trash truck.
Mrs. Maucher opened the public hearing.
Mr. Allan Angel – Levy Court Commissioner for Kent County
Mr. Angel stated that he is a Levy Court Commissioner and he knows this area very well. As
Chair of Economic Development and or Levy Court for Kent County, he loves to see businesses,
small and large flourish; however, a Day Care with 170 children at this location raises some
major concerns. The first concern is traffic; bringing children in and dropping them off is an
issue because that area is so traffic heavy because of John Hunn Brown Road and South Little
Creek Road. It is very congested and hard to get in and out of at times and sometimes you see a
little road rage when you are sitting there for long periods of time. Our County walking trails
back right up to this property where the public individuals can be close to children. He would
hope that the applicant will put a fence up for safety. The homeless are living in that area and
urinating and defecating up to the tree line at the war memorial in that area. Since only a portion
of that building is going to be utilized, the unknown of what else could be part of that building
leaves an uncertainty of what else could be next to those children in that Day Care. Finally, our
most precious cargo are our children and they need to be in a safe environment.
3
6
Page 7
Item 1.
CITY OF DOVER PLANNING COMMISSION March 15, 2021
Mr. Michael Petit de Mange – County Administrator for Kent County
Mr. Petit de Mange stated that he wasn’t aware that Mr. Angel was going to be speaking tonight
and he thinks that he covered most of his concerns. The only point that he wants to share with the
Commissioners is about the outdoor play area that is planned to be fenced. He was wondering if
the fencing will continue all the way to entrance/exit of the building where the children will be
coming and going. He could not make that out from the plan and it was a little unclear to him if
the fencing just kind of ends at the building as a gate. If that’s the case, they would be concerned
about children going to and from the Day care to the play area. It looks like they would have to
walk out and into the fire lane to get there. He shared the plans with Levy Court leadership and
that was one concern that was noted. Other than that, he thinks that the use would be a good
neighbor and they certainly support child care activities. East Dover Elementary is in the area
also and their playground is fenced in as well. They have never had any concern with (children at
the school) getting out into traffic there and they would like to see the same consideration here at
this facility. Responding to Mr. Petit de Mange, Ms. Johnson stated that the exit from the
building to the playground is right near the playground. So towards the end where the children
will be entering, you literally come down a hall, come out and step right into the playground on
both sides.
Mrs. Melson-Williams stated that they do go through an area that is not totally fenced from the
building into the play area but there is a short distance where they would obviously be under
teacher control to make that gap happen. Responding to Mrs. Melson-Williams, Ms. Johnson
stated that the playground was a few steps from the building.
Mrs. Melson-Williams stated that you do not open a door directly to the play area because that
door is likely serving as egress purposes as well.
Mr. Petit de Mange stated that it did answer the question but it did not satisfy the concern. There
is a space between the entrance/exit and the playground that is not fenced. That is really the point
that we wish to raise just for safety purposes and also Mr. Hartman mentioned the fire lane and
the access to the dumpsters as well. He just thinks that it is important, particularly when you are
dealing with youngsters and a sizeable number of them, that the fence be contiguous to
entrance/exit where they are coming and going so that no mishaps occur.
Mrs. Lord questioned how many feet is the exit of the building to the fence of the playground?
Approximately how many feet will the teachers and the children have to travel to get to the
playground? Responding to Mrs. Lord, Ms. Johnson stated that the back entrance would be the
main entrance, not the one that is by the fire lane which will only be used for fire drills or
emergencies. They will mainly use the back entrance but she believes that there is approximately
five feet between the entrance and the fence for the playground.
Mr. Spiegelman asked if they could zoom out on the drawing because there may be a scale to
determine exactly how far it is. More importantly, when we are saying “back entrance”, what
they are talking about is the entrance on the east side of the building. In the playground area
directly to the south, there is a set of steps and so it is kind of tucked away behind the fence. That
allows for an added level of security but also importantly, they need to be careful about fencing
in a potential exit because of fire violations. The idea is that the kids need to be able to get out
4
7
Page 8
Item 1.
CITY OF DOVER PLANNING COMMISSION March 15, 2021
rather than into a fenced in area in case of an emergency. A lot of times it is actually added
safety to have a short walk such as this directly to it. If everything on the plan is to scale, then
they could argue that it is half of a dumpster length or it is about the width of a parking spot; so,
probably less than 10 feet.
Mrs. Lord stated that when you are making sure that they have egress from the building without
having to scale a fence should there be a fire or other emergency, that is a fairly short distance to
go. She knows that they have all seen Day Cares where the children hold hands and are sort of
herded in and herded out. It’s not like they are just running out there to the playground on their
own. From her perspective, she does not see that being a possible safety threat.
Mr. Petit de Mange asked if someone could point on the elevation where that exit is. It looks like
you would have to walk out of the building into the fire lane to get to the playground, but he may
be mistaken. Responding to Mr. Petit de Mange, Mr. Spiegelman stated that the east entrance is
going to be the main entrance to move kids from the Day Care into the playground. There is a
hallway where kids would go out from the Day Care to the exit that is going to be at the east side
of the building and enter the playground from the south. That is going to be the main entrance,
thereby avoiding the kids being anywhere near the fire lane at all.
Mrs. Melson-Williams stated that she is not sure that the elevation shows the depiction of
improvements that are planned on the east side of the building. Responding to Mrs. Melson-
Williams, Mr. Petit de Mange stated that he sees new steps there and they are right at the edge of
the fire lane.
Mrs. Maucher closed the public hearing.
Mr. Hartman moved to postpone application C-21-02 JJ’s Learning Experience 2 Child Day
Care Center at 756 South Little Creek Road until the next meeting so that issues involving the
parking, the lighting, the traffic flow and the children’s access to the playground can be
reviewed and formalized and presented again to the Commission, seconded by Mr. Adams and
the motion was carried 9-0 by roll call vote. Mr. Hartman voting yes; based on the concerns with
the safety of the children. Mr. Baldwin voting yes; based on the safety issues. Mrs. Lord voting
yes; based on reasons previously stated. Mrs. Welsh voting yes; she thinks it is best to clarify
what is happening with the issue of children being escorted to the playground. Dr. Jones voting
yes; she would say that due to the safety of the children she has to vote in favor of the motion but
she believes that Ms. Johnson will come back with appropriate information that is probably
already there. Mr. Roach voting yes; he appreciates them trying to bring forth a child care
facility to this area because it is a much needed addition to the City. He is not as concerned
about some of the concerns but it is just more clarity. Working at on elementary school, he
definitely knows why the fire lanes are close to the building but he would definitely like more
clarity on the lighting and the parking spaces. Mr. Adams voting yes; he would tell the applicant
to please not be discouraged. They are excited about the project, but he just thinks there is just a
little more information that they need in order to move forward. Mrs. Malone voting yes; for
reasons stated. Mrs. Maucher voting yes; for reasons provided in the motion.
5
8
Page 9
Item 1.
CITY OF DOVER PLANNING COMMISSION March 15, 2021
C-21-03 Warehouse Building at College Business Park Lot D – Public Hearing and Review of
Conditional Use Site Development Plan to permit construction of a 9,520 SF one story
Commercial Warehouse Building with associated site improvements on a 0.9907 acre +/- parcel.
The property is zoned M (Manufacturing Zone). The property is located north of College Road,
at the end of College Park Drive, abutting the southwest side of the railroad right-of-way. The
owner of record is Stoltzfus LLC (HSM Exchange LLC). Property Address: 1255-1257 College
Park Drive. Tax Parcel: ED-05-067.00-02-12.06-000. Council District 4. Consideration of
Performance Standards Review Application. Waiver Request: Partial Elimination of Upright
Curbing. Application C-15-03 Cellco Partnership dba Verizon Wireless at 1255 College Park
Drive approved by Planning Commission in August 2015 and Final Plan Approval on January
11, 2016 developed a telecommunications monopole (Towed Based Wireless Communications
Facility) on the property.
Representative: Mr. Doug Liberman, Larson Engineering
Mr. Swierczek stated that this is a proposal for a warehouse building on Lot D in College
Business Park off of College Road. Currently on the site, there is an existing telecommunications
monopole (cell tower). This structure is proposed to remain. There is also a trailer present on the
site which will be removed to accommodate this. With the proposal Site Plan submitted, the
applicants have also submitted a Partial Elimination of Upright Curbing Waiver Request as well
as a Performance Standards Review Application which is required for development in a
Manufacturing Zone. For parking on the property, the site in general has not had a specific tenant
identified yet so for specific items that are sometimes required based on employees or square
footage totals, they would have to assess that based on square footage. The applicant is showing
that they are being compliant with the minimum required parking by providing twelve parking
spaces. They have added details noting that they will be providing bicycle parking as required.
At the moment, they are identifying one loading area shown at the top of the Site Plan which is
sort of to the northeast of the property. For this loading area, once again, there are requirements
that are based generally on square footage or the type of use there. This does meet minimum
requirements. Once a tenant is identified and they go through the permit process, they will be
obviously assessing this to see if it is efficient enough for what they are proposing. The Partial
Elimination of Upright Curbing submitted as a Waiver Request does pertain to that loading space
area as it does partially overlap an easement for stormwater drainage. They have indicated to the
applicant that any proposed developments should ensure that it is not going to impede
stormwater management there at all. It might look a little confusing where you see the entrance
of the site. The drive that this is on, College Park Drive, is not a City maintained road nor is it
DelDOT. It is a privately maintained road. On the plans that were submitted by the applicant,
they did show that what was recorded as right-of-way is not actually what was built as right-of-
way. What was recorded was that slightly larger cul-de-sac feature that ends a little lower down.
However, what was built is that slightly smaller cul-de-sac that extends closer to the edge of the
property lines. They did advise the applicant that they could revise their Site Plan submission to
reflect that; however, they will have to ensure that any easements be recorded as necessary which
will be part of the plan review process moving forward. They did also provide some building
architecture. It does show elevations of each of the four sides of the building. It does not note
anything like materials. It does give a general indication to things like doors, windows, and
garages (doors). That will be more specifically identified once a tenant is identified for the space.
6
9
Page 10
Item 1.
CITY OF DOVER PLANNING COMMISSION March 15, 2021
As a note, if anyone was sort of looking into this property, there did appear to be woodlands on
the site in the not too distant past; however, the applicant has submitted some information with
the public notice requirement that shows that the woodland was in fact lost to the recent storms
that impacted that area. To the waivers submitted and the Performance Standards Review
Application, it is noted that the Partial Elimination of Upright Curbing is an administrative
Waiver that is at the prevue of Planning Staff to approve. As a note to the members of the
Commission, Staff has approved it. They are also recommending approval of the Performance
Standards Review Application, believing that the form submitted by the applicant sufficiently
demonstrates the intent to comply with the restrictions on objectionable elements as noted in the
Zoning Ordinance, Article 5, Section 8.1 and 8.2.
Mr. Liberman stated that they have a Conditional Use Site Plan for a contractor’s warehouse on
an approximately one acre lot. Mr. Swierczek just about covered everything for this application.
They have the required parking and they have extended the sidewalk along the frontage. They
have relocated the right-of-way to match the existing cul-de-sac that is out there. They have
added a bike rack. The drive aisles out front are suited for the contractor warehouse use. They
have a 28 foot wide drive aisle as opposed to a 24 foot wide and they added an additional 8 foot
concrete apron to help with maneuverability for the contractors using the site. He appreciates the
approval of the waiver. That area is really from the trash dumpster heading east away from the
building. The stormwater will sheet flow across that paved area to the stormwater pond located
just south of the building. They did submit the Performance Standards Review Application. Like
Mr. Swierczek said, they do not have tenants at this point but given the Performance Standards
for dangerous and objectionable elements, he doesn’t think that Mr. Stoltzfus would want to have
anyone in the building that is going to be using or generating the items listed within the City of
Dover Code. Fire and explosion hazards, radioactivity, noise, vibration, smoke and all of that
type of stuff just isn’t good for the area. He does not feel that they would be putting anyone in
there who would want to generate anything like that. Mr. Swierczek had a comment on the
architecture. It is to be a metal building. This building is industrial or manufacturing in use so a
metal building will be sufficient for what is needed out there and given the location of this
building at the very end of College Park Drive.
Mr. Hartman stated that the Performance Standards (responses) that are provided are very open.
He understands that since they don’t know what kind of tenants are going in there, but the
Commission is tasked with approving the Performance Standards. He would just like to know
that somebody along the line, either the City level or the applicant, will be verifying that the
tenants will be at least aware of the Performance Standards so that they can comply with them.
Some of the Performance Standards involve solid waste and things of that nature which are
throughout the area. He would like to just understand who at the City or who at the applicant’s
level will be ensuring that the tenants will be aware of the Performance Standards and will at
least understand that there are Performance Standards to be complied with. Responding to Mr.
Hartman, Mr. Swierczek stated that once the building is constructed and a tenant is identified,
whenever they move into this location it has to go through a permit review process. Any permit
for something like that does have to come to the Planning Office for review. At that stage, they
will review it to ensure that whatever is being proposed onsite is compliant with the Performance
Standards Review and is compliant with what the applicant has submitted. If it is not compliant,
that would obviously stop that from proceeding further until their concerns could be addressed
7
10
Page 11
Item 1.
CITY OF DOVER PLANNING COMMISSION March 15, 2021
on that end.
Mrs. Maucher opened a public hearing and after seeing no one wishing to speak, closed the
public hearing.
Mrs. Welsh moved to approve application C-21-03 Warehouse Building at College Business
Park Lot D for the addition of a 9,520 SF commercial warehouse building, inclusive of all DAC
comments, the Waiver Request for the Partial Elimination of Upright Curbing and the
Performance Standard Review Application, seconded by Mrs. Malone and the motion was
carried 9-0 by roll call vote. Mrs. Welsh voting yes; it seems to be a good use of the area and
space. Dr. Jones voting yes; she agrees that we should keep an eye on compliance with the
Performance Standards. Mr. Adams voting yes; for reasons previously stated. Mr. Roach voting
yes; for reasons previously stated. Mrs. Malone voting yes; for reasons previously stated. Mr.
Hartman voting yes; he agrees with the commentary that the Planning Office provided. Mr.
Baldwin voting yes. Mrs. Lord voting yes; for reasons previously stated. Mrs. Maucher voting
yes; based on Staff comments and the reasons stated in the motion.
S-21-02 Academy of Dover Charter School at 104 Saulsbury Road - Public Hearing and Review
of a proposed Site Development Plan Application to permit construction of a 7,072 SF one story
School Building behind an existing 37,960 SF School Building. The Plan also shows additional
landscaping to meet code requirements. The property measures 4.757 acres +/- and is located on
the west side of Saulsbury Road approximately 900 feet north of Forrest Avenue. The property is
zoned IO (Institutional and Office Zone) and is subject to the COZ-1 (Corridor Overlay Zone).
The owner of record is Dover School LLC. Address: 104 Saulsbury Road. Tax Parcel Number:
ED-05-076.07-01-27.00-000. Council District 1. Waiver Request: Elimination of Fence
Component of Opaque Barrier and Alternative Format of Opaque Barrier. The property was
originally developed with Site Plan S-02-27 Dover Academy Charter School approved by
Planning Commission October 21, 2002.
Representatives: Mr. Doug Liberman, Larson Engineering; Ms. Michele Marinucci, Principal
for Academy of Dover
Mr. Baldwin recused himself from this application as his daughter works for Academy of Dover
Charter School.
Mrs. Bulkilvish stated that this application is for a Site Plan for an additional school building on
the property located at 104 Saulsbury Road. This property was previously developed under Site
Plan S-02-27 for the Dover Academy Charter School and the property is zoned IO (Institutional
and Office Zone) and is subject to the COZ-1 (Corridor Overlay Zone). The property has been
developed in accordance with the COZ-1 (Corridor Overlay Zone) so a lot of the features that are
required for that are already established. Currently, there is a 7,072 SF building being proposed
at the rear of the existing 37,960 SF building. In addition, they are proposing some pedestrian
linkages around the building to get students safely to the play area located even further to the
rear of the property without having to pass through the parking area. The applicant is also
requesting a Waiver for the Elimination of the Fence Component of the Opaque Barrier
requirements as well as Alternative Format of Opaque Barrier. They have submitted their request
8
11
Page 12
Item 1.
CITY OF DOVER PLANNING COMMISSION March 15, 2021
in writing as well as a diagram showing the existing conditions on the property. When this was
previously developed, the property to the south was zoned IO (Institutional and Office Zone) and
it has since been rezoned and now requires that Opaque Barrier along the south boundary. It is
heavily vegetated; and therefore, the applicant is requesting that Waiver for the Opaque Barrier.
They are proposing additional plantings in that area to create a thicker vegetative barrier in
places where it may be thinned out. Previously approved too was a Waiver for the Opaque
Barrier with the original Site Plan for the western property line as it is heavily wooded there and
that also butts up to a residential area.
Mr. Liberman stated that this is for a 7,520 SF freestanding classroom addition to provide space
for up to 60 students. He thinks that they were looking to add approximately four new employees
along with the expansion so there is not a large demand on the parking lot that already exists.
The parking will not be changed from what is originally proposed there because parking is based
off of the size of the auditorium and that is not changing. The site is located in the COZ-1
(Corridor Overlay Zone) and meets the site layout, landscaping and architectural requirements of
the COZ-1 (Corridor Overlay Zone). Utilities for water and sewer are being extended from the
existing services that are serving the existing building. They are asking for a Waiver of the Fence
Component of the Opaque Barrier requirements along the south and west property lines. These
areas are heavily wooded and the same waiver was granted previously. The buffer has only
gotten thicker with time. The zoning on the southern property line actually changed after the site
was constructed so the fence then became a requirement. It was actually after our site was
already built that the fence requirement came in. It will be very costly to have to remove all of
the vegetation along our property line that is 700 feet long and then install trees and shrubs and
the fence; it just doesn’t seem like a good use of time and money to be able to do that.
Additionally, it seems like the fence component screens the parking lot from the residential use
and the building is essentially going to be covering or screening the parking lot from the senior
apartments to the south. The DAC comments were fine.
Ms. Marinucci stated that their plan with this expansion of our Academy is to have a minimum
impact to those around us while we are also providing a major impact to the families that they
serve. This really just allows them to spread out their students and they are adding two grades.
For the most part, it is going to be for the same families that they serve. Our families tend to have
all of their children come through the Academy. So, the impact itself on surrounding areas
should be very minimal.
Dr. Jones questioned if the Planning Office heard from any of the neighboring communities or
residents surrounding this area? Responding to Dr. Jones, Mrs. Bulkilvish stated no, they have
not received any comments from the neighboring properties.
Mrs. Maucher opened the public hearing and after seeing no one wishing to speak, closed the
public hearing.
Mr. Hartman moved to approve Application S-21-02 Academy of Dover Charter School at 104
Saulsbury Road to permit the construction of a 7,072 SF building behind the existing building
and to include the Waiver to Eliminate the Opaque Barrier Fence requirement for the south and
west property boundaries recognizing the presence and maintenance of the existing trees and
9
12
Page 13
Item 1.
CITY OF DOVER PLANNING COMMISSION March 15, 2021
vegetation along those property lines, seconded by Mrs. Welsh and the motion was carried 8-0
by roll call vote with Mr. Baldwin recused. Mr. Hartman voting yes; based on the
recommendations of the Planning Office and their DAC comments. Mrs. Lord voting yes; based
on reasons previously stated. Mrs. Welsh voting yes; for reasons stated in the motion. Dr. Jones
voting yes; for reasons previously stated. Mr. Adams voting yes; he wishes the school good luck
in this project. Mr. Roach voting yes; this additional space will be a welcomed addition and he
hopes that everything goes well. Mrs. Malone voting yes; she thinks that it is a good project and
also for reasons previously stated. Mrs. Maucher voting yes; based on Staff comments and DAC
comments.
S-21-03 Three Lots at Secure Storage on Lafferty Lane: Master Plan - Public Hearing and
Review of a Site Development Master Plan Application to permit development of three (3)
existing parcels. The parcels are listed as Lots 2, 3, and 4 respectively; with Lot 1 being the main
parcel for the Secure Storage Facility. Lot 2 is proposed to contain a Building of 23,600 +/- SF
with associated site improvements. Lot 3 is proposed to contain a Building of 23,600 +/-SF with
associated site improvements. Lot 4 is proposed to contain a Building of 21,400 +/-SF with
associated site improvements. The proposed development area of the three Lots totals 7.67 acres
+/- and is zoned IPM (Industrial Park and Manufacturing Zone). The land tracts are located on
the north side of Lafferty Lane and east of Bay Road. The owner of record is Secure Storage
LLC. Property Addresses: unaddressed but are adjacent to 640 Lafferty Lane. Tax Parcels: ED-
05-077.00-01-25.01-000, ED-05-077.00-01-25.02-000, and ED-05-077.00-01-25.03-000.
Council District 2. Waiver Requests: Elimination of Sidewalks, Partial Elimination of Upright
Curbing and Consideration of Performance Standards Review Application. The three Lots were
created as part of a Minor Subdivision Plan with Site Plan S-02-23 Secure Storage LLC for
Mini-Storage Facility (Lot 1) in 2002.
Representative: Mr. Jonathan Street, Becker Morgan Group
Mr. Swierczek stated that this is a Site Development Master Plan for three lots on Lafferty Lane.
They are noted as Lots 2, 3 and 4 with Lot 1 being the primary and already developed lot for the
Secure Storage itself. This is being proposed as a Site Development Master Plan as once again,
the applicant has not identified any specific tenants. They have notified Planning Staff that they
have been in some discussions with some businesses. They are looking to have some perspective
developments approved so that they might be able to move forward in order to accommodate
that. This would be allowed as a Site Development Master Plan and then the specific lots might
be able to move forward under an Administrative Review. There isn’t specific phasing identified
in that regard. It is mainly to address the ability to move forward with that additional
Administrative Review. The buildings as shown on Lots 2 and 3 are each currently shown as
23,600 SF and with the building on Lot 4 identified as 21,400 SF. All three buildings are sharing
a single access point off of Lafferty Lane that connects into Lot 3. This is the sole component of
those that they could obviously identify that has to be developed first as that access point would
allow for construction to be done on all three lots. The applicant has similarly noted a 60-foot
cross-access easement being implemented across the entire frontage of Lot 3 that would allow
that access road to connect to Lots 2 and 4 as well. There is no interconnectivity shown between
any of these lots and the primary Lot 1. The most recent application for this overall site was from
2017 that proposed putting in the final Phases 2 and 3 of construction to Secure Storage. They
did submit a Waiver Request for that application to eliminate the requirements for sidewalks
10
13
Page 14
Item 1.
CITY OF DOVER PLANNING COMMISSION March 15, 2021
along the Lafferty Lane frontage. They have similarly submitted a Request to also eliminate
sidewalks across the Lafferty Lane frontage on these three properties. They have further
submitted an administrative Waiver Request for the Partial Elimination of Upright Curbing. This
pertains to certain areas around the parking lots and the added drive on Lot 4. Each of the
buildings is shown to be approximately one story. Again, these do not have any building
architecture (submitted). If there were any more specifics to be identified, that will come across
for review by Planning Staff. There is a fenced in yard identified at the rear of all three of these
buildings and there is a loading space identified at the rear of each of these buildings as well. The
appropriateness of the loading facilities and the parking as well will be further addressed upon
further review by Planning Staff through an administrative process as well as the permit review
process. Another key thing that Staff notes is on Lot 1, immediately adjacent to Lot 4, there is an
unmarked cemetery. This is something that came across when DelDOT was surveying for the
construction of Lafferty Lane. In the development of Lot 1, it was identified that the applicant
should obviously be cognizant of that cemetery and similarly to do so here with the development
of Lot 4. The main thing is that they have again submitted a Performance Standards Review
Application as this is an IPM Zone site. They have submitted that for review by the Planning
Commission. Planning Staff has approved the administrative Waiver for the Partial Elimination
of Upright Curbing. As it pertains to the Performance Standards Review, Planning Staff would
again recommend approval of the Performance Standards Review noting that we will be further
reviewing each one of these sites through an additional administrative process as well as a permit
review process and any potential objectionable or hazardous materials to be used by any tenant
would raise a red flag for the Planning Staff along with the elimination of curbing, Planning Staff
is recommending that the Planning Commission waive the requirements for the sidewalks along
the frontage of Lafferty Lane as they did in the 2017 application for Lot 1. If sidewalks were to
be provided right now, they wouldn’t connect to anything. There is no other sidewalk along the
Lafferty Lane frontage. However, the Waiver Request also noted that they were requesting to not
have to provide a sidewalk linking the three buildings providing internal pedestrian access.
Planning Staff was not recommending approval for that but they of course welcome the
commentary by the applicant. As the applicant noted, there has not been a tenant identified yet
for any one of these three sites. Supposing that there might be some type of connectivity between
these potential businesses, it would be more beneficial to provide a pedestrian only access
sidewalk as opposed to having people using drive aisles or the parking lots to access one
property from another.
Mr. Street stated this application is for a Site Master Plan and what that does is gives the
applicant the ability to build each building or each lot separately and also allows them for a little
bit more flexibility. Each one of these lots, as they would be developed, would still have to come
before Planning Staff and would still have to meet the criteria of the Master Plan as you see it.
They are in receipt of Staff comments and they don’t have any comments to them, with the
exception of a couple things. For the Planting requirements in the DAC he and Mrs. Melson-
Williams discussed them with the applicant. They had requested that the planting requirement be
something less than the 7.76 acres of site area. You can see on the plan that there is a large area
at the back of the site made up of stormwater management and a water swale. There are also
areas of easement. There is a water line that runs between Lots 2 and 3. So, there is some area
that is undevelopable that they can’t necessarily touch and they are asking that it be removed
from the requirements. He thinks that it is mentioned in the comments that the tenants of each
11
14
Page 15
Item 1.
CITY OF DOVER PLANNING COMMISSION March 15, 2021
specific area could be worked out administratively. They have a landscape plan that puts up 95
trees so he thinks that they are good with the area as long as they and Staff can work that out; he
doesn’t think that there will be any problems. With regard to the Performance Standards, he
wanted to make sure that Mr. Hartman was satisfied. Although, he thinks this application is very
similar to another application that was heard tonight where they don’t know the tenants right
now. They know that it is going to be more of warehousing and construction type uses and those
standards would be reviewed by Staff as each administrative application comes through for them.
With regard to lighting, lighting will be done on the parking lots and any impervious surface as
per the City Code requires. You can see from the Site Plan in front of you that the site is going to
have one main access from Lafferty Lane and then separate into the three individual lots; and
that cross-access easement was previously recorded for this plan. With that, the partial
elimination of the curb, they will often request a partial elimination of curbing for these sites to
make way for stormwater management. Stormwater management on the site has previously been
approved and managed but they will still have to submit to the Kent Conservation District to
confirm impervious areas are covered with drainage; and they will issue that approval of that
plan. They request the partial elimination so that water can sheet-flow off of the parking areas
and the rear will have some amount of gravel used for turning areas for trucks and loading. It is a
little bit easier to control stormwater when it is just able to sheet-flow off the ground. Often when
we install curbs, we have to install closed drainage systems. This is a more natural and a little bit
easier to control when you are just running it off of the property. With regard to the sidewalk and
the Sidewalk Waiver that they requested, we thank the Planning Staff for requesting the
elimination of sidewalk off of Lafferty Lane since this project has requested that on multiple
phases that it has gone through during years of development. With regard to the elimination of
(internal) sidewalk, they won’t put up too much of a fight for the interconnection between the
lots and they can provide that sidewalk without question.
Dr. Jones questioned if the Site Development Plan approval requires measures that will protect
this (cemetery) area? Responding to Dr. Jones, Mr. Swierczek stated yes, the unmarked cemetery
actually does lie on Lot 1 and there were measures taken then to assure that the applicant did not
disturb it. There were recommendations of putting up some type of temporary fence to ensure
that no construction equipment would crossover that area even though construction wasn’t really
being conducted in that area immediately. He thinks something similar would happen in this
situation.
Dr. Jones further questioned if that is the case, who is accountable for calling the stoppage if
there are human remains discovered? Responding to Dr. Jones, Mrs. Melson-Williams stated that
the Unmarked Human Remains Law that is part of Delaware Code requires that anybody coming
across from what could be perceived as human remains during construction activity is charged
with stopping. Then there is a process that involves the State Historic Preservation Office for
evaluation of whether that is in fact unmarked human remains. There is a fairly succinct process
for dealing with that. The limits of the cemetery were fairly well studied during the requirements
that DelDOT had to do with the Lafferty Lane relocation a number of years ago associated with
the construction of State Route 1. The activities that would involve construction on these three
lots are not within that cemetery boundary but there is always the possibility for outliers of
course. So, that is why we make mention of it but certainly there is some stormwater
management that is between the project sites and the location of the cemetery. It is a bit of a
12
15
Page 16
Item 1.
CITY OF DOVER PLANNING COMMISSION March 15, 2021
distance so there is a comfort level there, but there is certainly activity in place and their plan
itself actually defines the basic area of the cemetery anyway. She thinks that there are reasonable
preventive measures there as we know where the bulk of it is. But that’s not to say that there
might be something beyond that but there had been a lot of study done previously on the
cemetery. The property owner is one in the same, so they are well aware of the presence in close
proximity.
Mr. Street stated that that area of the cemetery is located off of our property. Those updated Kent
Conservation District plans as well as any Administrative Site Plan that would come through
Staff’s Office, would define a limit of disturbance. That limit of disturbance the State uses on a
State level is for construction activity and that limited disturbance would not cross that property
line without written authorization from the neighboring parcel. He understands that the
neighboring parcel has the same owner, but there is no need for them to be over there. Frankly,
they pay a fee based on the area of limited disturbance so we try and keep that limit as small as
we possibly can.
Mrs. Maucher opened a public hearing and after seeing no one wishing to speak, closed the
public hearing.
Mrs. Welsh moved to approve application S-21-03 Three Lots at Secure Storage on Lafferty
Lane: Master Plan, inclusive of all of the DAC comments and the waiver requests for the
elimination of sidewalk, the elimination of upright curbing and the consideration of the
Performance Standards Review Application, seconded by Mrs. Malone and the motion was
carried 9-0 by roll call vote. Mrs. Welsh voting yes; for reasons previously stated and she thinks
that it is a good expansion of the property. Dr. Jones voting yes; for reasons stated in the motion
and it will be a good addition to that area. Mr. Adams voting yes. Mr. Roach voting yes. Mrs.
Malone voting yes; she thinks that it is a good project for the area. Mr. Hartman voting yes; the
proposal is in accordance with Code and he would suggest to the applicant that they might want
to install the internal sidewalk linkage as suggested by the Planning Office. Mr. Baldwin voting
yes; based on reasons previously stated. Mrs. Lord voting yes; based on reasons previously
stated and would also like to see the internal sidewalk installed. Mrs. Maucher voting yes; based
on the DAC comments.
SB-21-01 Lands of Bayroadcap, LLC at 600 Bay Road: Minor Subdivision Plan - Public Hearing
and Review of a Minor Subdivision Plan to subdivide the Bay Road Commercial property
consisting of 12.94 acres +/- into two parcels (Lot 1 and Lot 2). Lot 1 is to be 4.95 acres+/- and
encompass the western portion of the property developed with Phase 1: Building, stormwater
management facility, and parking area. Lot 1 does not have frontage on Bay Road. Lot 2 is to be
7.99 acres+/- and encompass the eastern residual portion of the property with frontage on Bay
Road. The subject property is located on the west side of Bay Road near its intersection with
Blue Hen Boulevard and the Bay Court Plaza entrance drive. The property is zoned C-4
(Highway Commercial Zone). The owner of record is Bayroadcap, LLC. Property Address: 600
Bay Road. Tax Parcel Number: ED-05-077.00-01-09.00-000. Council District 2.
Subdivision Waiver Requested: Elimination of Requirement for Lot Frontage on a Public Street.
Application S-19-20 Delaware State Police Building Update at Bay Road Commercial was
approved by the Planning Commission in September 2019 and received Final Plan Approval on
13
16
Page 17
Item 1.
CITY OF DOVER PLANNING COMMISSION March 15, 2021
March 6, 2020 regarding the development of the Lot 1 area superseding Application S-17-20.
Application C-20-02 Landing Square: Revised Phase 2 Area was approved by the Planning
Commission on August 17, 2020 for the commercial development of the Lot 2 area.
Representative: Mr. Jonathan Street, Becker Morgan Group
Mrs. Melson-Williams stated that this is a Minor Subdivision Plan. We have seen this subject
site a number of times in recent years, but this is a proposal to subdivide what is a 12.49 acre
parcel into two lots. Lot 1 being the smaller of the two and focused on the western extremes of
the property and then Lot 2 being just less than 8 acres and being the eastern portion of the
property with frontage specifically on Bay Road. The property is zoned C-4 (Highway
Commercial Zone) and both parcels would remain that zoning classification. For previous
history, there have been a number of projects. The two most recent of note is what is proposed
here in the Lot 1 area was developed under the Site Plan Application S-19-20 the Delaware State
Police Administration Update to the Bay Road Commercial site. There is that existing building
there now and their parking and some stormwater management which will serve Lot 1 as well as
some areas of Lot 2 likely. The Lot 2 area is the subject of the Site Plan piece of C-20-02 The
Landing Square, also known as the Revised Phase 2 area which is just the site development for
an office building and then two restaurant pieces out along Bay Road should they move to that
direction. If you will remember those applications, access to the site is with a right-in/right-out
off of Bay Road along the property frontage but the main real access to the property occurs by
traveling over what they call the Baycourt Plaza entrance drive. That is not public right-of-way;
it just happens to be a named entrance drive which has easements that allow access to the subject
parcel as well as to a property owned by DelDOT and DTC that is to the further west. The
Baycourt Plaza entrance drive is not right-of-way. Because with the kind of Z-shaped property
line that they are requesting to strike to divide this into two lots leaves Lot 1 without specific
frontage on a public street. That is a requirement of our Land Subdivision Regulations; however,
there is the ability for the Planning Commission and then ultimately City Council, to consider a
waiver of the Subdivision Regulations to remove that requirement. They are seeking this waiver
as Lot 1 does not have frontage on a public street. It has the ability to access a public street by
the easement that exists along the Baycourt Plaza drive and then also if additional easements are
established across Lot 2 for it to reach Bay Road. Lot 2 has the required frontage on Bay Road.
Any time that we are striking a property line, we have to look at the bulk standards for the zone.
With this being C-4 (Highway Commercial Zone), they have looked at that and the second sheet
of their submission very specifically shows where the building is on Lot 1 so that we can confirm
that setbacks from property lines as met. Likewise, that will also have to be confirmed with the
development that was recently approved on Lot 2. In recent weeks, it went to Final Plan
Approval so they will need to double check that the new proposed property line doesn’t impede
any required setbacks there. For the balance of the development, that really is related to the
approved development plans that exist so things like parking, sidewalks and tree plantings are
covered under a Site Development Plan Review. As she said, Lot 1 is pretty much completed its
development at this point, but Lot 2 will be subject to the plans that are recently approved for its
development. There were comments from the other regulatory agencies that are included in the
packet, but Staff finds that the creation of two lots generally complies with our Land Subdivision
Regulations. Dividing it into two lots does not impede its future development; however, we do
need to address the Subdivision Waiver for the requirement of the lot to have frontage on a
14
17
Page 18
Item 1.
CITY OF DOVER PLANNING COMMISSION March 15, 2021
public street. Staff does recommend that that Waiver be granted and in doing so, that you require
the cross access easements to be very specifically established to ensure both Lot 1 and Lot 2 can
make use of that Baycourt Plaza entrance drive to reach Bay Road which is the public street in
this general area and that there are also appropriate easements associated across Lot 2 and
between these two Lots to cover things related to utilities, site circulation, and the like. With a
Subdivision Waiver, the Planning Commission is making a recommendation and that
recommendation must be forwarded to City Council.
Mr. Street stated that what you are looking at tonight is simply the subdivision of two properties.
What you are not seeing on the plan are the cross access easements. There are currently cross
access easements between not only Bay Road and the neighboring property to the north where
Century Engineering is now. You can actually see that cross access easement there defined on the
plan, but it also includes the attorney’s office out front as well. Also, what you are not seeing on
the plan that was deeded is that the project will provide sewer not only to both Lot 1 and Lot 2,
but also that parcel out front as well. That will have to be restated and re-recorded to include new
parcel numbers and owners if the Waiver is granted. The cross access easement that is currently
on the Baycourt Plaza side which is the boulevard entry, that was actually made up of two
different easements prior to the original approval to this a couple of years ago. They actually
researched that and cleaned that up for our parcel in its entirety. DelDOT and DART are both a
party to that and that obviously would remain as it has been a long standing easement that
provides not only our parcel access but the DART facility access as well. As part of the State
Police project, they also included that interconnection there to make the bus traffic in and out a
little easier and well organized. With that, they are in receipt of Staff’s comments; they don’t have
any real concerns with comments. The cross access easement that Mrs. Melson-Williams was
stating would have to be recorded and taken care of. The State Police facility is kind of its own
little parcel there as Lot 1. The stormwater management that is on the north side of them, serves
both what would be Lot 1 and a small portion of Lot 2; so, there will be some sharing of
maintenance responsibilities. It is going to be the same owner, but this is still a typical agreement
that happens. Most recently the last one that he did was across the street to the south with the
DSWA and the Chesapeake Utilities site. The stormwater management pond is located on the
Chesapeake Utilities parcel, but it feeds the entire business park and there is an agreement of who
maintains what and what percentages of maintenance needs to be done. This is a typical
agreement and it is something that they are already aware of and are already working on. They are
not changing anything about current agreements that are in place with the exception of updating
parcel numbers and owners. They are not proposing to sell off any of these parcels. This is just
being done so that they can kind of reorganize the financing for construction because the State
Police Building is completed. This whole parcel (Lot 1) will essentially be done and signed off on
which allows them to then move on with development of Lot 2 and its financing.
Mrs. Maucher opened a public hearing.
Ms. Karen Vicks – 580 Bay Road Dover, DE 19901
Ms. Vicks stated that she did not have any comments; she is here for informational purposes.
Mrs. Maucher closed the public hearing.
15
18
Page 19
Item 1.
CITY OF DOVER PLANNING COMMISSION March 15, 2021
Mr. Hartman moved to recommend approval to City Council for SB-21-01 Lands of Bayroadcap,
LLC at 600 Bay Road: Minor Subdivision Plan to include the Waiver to eliminate the lot
frontage requirement for Lot 1 provided that cross access easements among both Lots 1 & 2 and
along the Baycourt Plaza entrance drive to ensure permanent access to Bay Road is secured and
that these easements allow for the owners of each lot to make any improvements necessary to the
internal circulation system as specified in the Zoning Ordinance Article 8, Section 1 to ensure
that internal circulation and site access to both lots are beneficial to the public health, safety and
general welfare, seconded by Mr. Adams and the motion was carried 9-0 by roll call vote. Mr.
Hartman voting yes; he agrees with the Planning Office’s commentary and the DAC
requirements in Section VII of the DAC Report. Mr. Baldwin voting yes; based on Staff’s
recommendations. Mrs. Lord voting yes; based on reasons previously stated. Mrs. Welsh voting
yes; based on DAC comments and that it is in compliance with plan for that site area. Dr. Jones
voting yes; for reasons previously stated. Mr. Adams voting yes. Mr. Roach voting yes. Mrs.
Malone voting yes; for reasons previously stated. Mrs. Maucher voting yes; based on Staff and
DAC comments.
NEW BUSINESS - None
Meeting adjourned at 9:15 PM.
Sincerely,
Kristen Mullaney
Secretary
16
19
Page 20
Item 2.
City of Dover, DE 2019 Comprehensive Plan
File: M:\PS_DATA\2018_Comp_Plan_Draft_Maps\Comp_Plan_2018_FINAL_MXDS\Map 12-1 Land Development Plan_Revised.mxd
Map 12-1: Land Development Plan As Revised on March 8, 2021
0 2,500
Hydrology
Roads
LEGEND
5,000 Feet
¯
Dover Boundary
Land Use
Active Agriculture
Commercial - Entertainment
Commercial - High Intensity
Commercial - Low Intensity
DoverAFB
Industrial
Institutional
Mixed Use
Office
Open Space, Conservation, Recreation
Public and Private Utilities
Residential High Density
Residential Medium Density
Residential Low Density
Train Track
Water Bodies
0 5,000 Feet
Inset Map
PAPER MAP DISCLAIMER:
By acceptance of this map material you agree to the following: This map material is
made available by the City of Dover, Delaware as a public service. The material is for
reference purposes only, and the City makes no warranty, re presentation, or guaranty as
to the accuracy of the material, including its accuracy, availability, use, and misuse. In
no event shall the City be liable for any direct or indirect damages suffered by the
Recipient or others arising from any inadequacies of the digital data or the Recipient's
use of this data. The material is in the public domain and may be copied without
permission. Citation to the source would be appreciated. Any errors or omissions in the
material should be reported to the City of Dover, Delaware's Public Works GIS 20
Division.
Page 21
Item 2.
City of Dover, DE 2019 Comprehensive Plan
File: M:\PS_DATA\2018_Comp_Plan_Draft_Maps\Comp_Plan_2018_FINAL_MXDS\Map 12-1A Land Development Plan_Revised.mxd
Map 12-1A: Land Development Plan As Revised on March 8, 2021
0 1,500
LEGEND
Dover Boundary
Roads
3,000 Feet
¯
Hydrology
Land Use
Active Agriculture
Commercial Entertainment
Commercial High Intensity
Commercial Low Intensity
DoverAFB
Industrial
Institutional
Mixed Use
Office
Open Space, Conservation, Recreation
Public and Private Utilities
Residential High Density
Residential Medium Density
Residential Low Density
Train Track
Water Bodies
0 10,000 Feet
Inset Map
PAPER MAP DISCLAIMER:
By acceptance of this map material you agree to the following: This map material is
made available by the City of Dover, Delaware as a public service. The material is for
reference purposes only, and the City makes no warranty, re presentation, or guaranty as
to the accuracy of the material, including its accuracy, availability, use, and misuse. In
no event shall the City be liable for any direct or indirect damages suffered by the
Recipient or others arising from any inadequacies of the digital data or the Recipient's
use of this data. The material is in the public domain and may be copied without
permission. Citation to the source would be appreciated. Any errors or omissions in the
material should be reported to the City of Dover, Delaware's Public Works GIS 21
Division.
Page 22
Item 2.
City of Dover, DE 2019 Comprehensive Plan
File:M:\PS_DATA\2018_Comp_Plan_Draft_Maps\Comp_Plan_2018_FINAL_MXDS\Map 12-1C Land Development Plan_Revised.mxd
Map 12-1C: Land Development Plan As Revised on March 8, 2021
0 1,500
LEGEND
Dover Boundary
Roads
3,000 Feet
¯
Hydrology
Land Use
Active Agriculture
Commercial Entertainment
Commercial High Intensity
Commercial Low Intensity
DoverAFB
Industrial
Institutional
Mixed Use
Office
Open Space, Conservation, Recreation
Public and Private Utilities
Residential High Density
Residential Medium Density
Residential Low Density
Train Track
Water Bodies
0 10,000 Feet
Inset Map
PAPER MAP DISCLAIMER:
By acceptance of this map material you agree to the following: This map material is
made available by the City of Dover, Delaware as a public service. The material is for
reference purposes only, and the City makes no warranty, re presentation, or guaranty as
to the accuracy of the material, including its accuracy, availability, use, and misuse. In
no event shall the City be liable for any direct or indirect damages suffered by the
Recipient or others arising from any inadequacies of the digital data or the Recipient's
use of this data. The material is in the public domain and may be copied without
permission. Citation to the source would be appreciated. Any errors or omissions in the
material should be reported to the City of Dover, Delaware's Public Works GIS 22
Division.
Page 23
Item 3.
The Institute for Public Administration presents
Real Estate Trends and the Pandemic:
How Will Land Use Change in Delaware?
COURSE INSTRUCTOR
Sean O’Neill, AICP
Policy Scientist, IPA
University of Delaware
April 23, 2021
Changes caused by the COVID-19 pandemic
have impacted our day-to-day lives and the built
environment around us. Remote work became normal,
10:00 a.m. to Noon online delivery services boomed, and many brick and
mortar stores suffered. Some trends that were already
occurring were accelerated by the pandemic, and
VIA ZOOM MEETING others were maybe a bit less anticipated. As our state
hopefully begins to come out of the pandemic in the
Registration in advance is required.
summer of 2021, what will these changes mean for the
After registering, you will receive a
confirmation email with information built environment in your community?
about joining the meeting.
Topics covered in this course will include:
$20 Registration Fee • Trends impacting the office, retail, residential, and
industrial warehouse sectors
Register Online • Feedback gathered from Delaware real estate
professionals
www.bidenschool.udel.edu/
• How your community can be proactive and adapt
ipa/events/upcoming to these changes
This session qualifies for certificate credit in the
Academy for Excellence in Local Government
Leadership. Contact Sean O’Neill (oneill@udel.edu) with
questions about this event.
23
Page 24
Duffield Associates, LLC
144 South GovernorsItem 4.
Ave.
Dover, DE 19904
Phone: 302.239-6634
Fax: 302.239-8485
duffnet.com
April 9, 2021
Mr. Julian Swierczek
Planner I
City of Dover
Department of Planning & Inspection
15 Loockerman Plaza
Dover, DE 19901
RE: Application No. S-19-07
Site Development Plan Application – Retail Facility at 515 South DuPont Highway
Tax Parcel No. ED-05-077.00-01-12.00-000
City of Dover, Delaware
Project No. 12000.CA (Duffield)
Dear Mr. Swierczek:
Duffield Associates, LLC (Duffield) is writing this letter, on behalf of Kent Del Properties, LLC, to
request an extension of the Planning Commission decision for conditional approval of the Site
Development Plan for the Retail Facility at 515 South Dupont Highway. The decision made at the April
15, 2019 Planning Commission meeting allowed for the construction of a one-story 8,050 square foot
retail building and accompanying site improvements. Per the Notice of Decision, the Site Development
Plan S-19-07 has until April 30, 2021 to start authorized construction.
Over the two years, the property owner has been working on Site Development Plans for the
development. This includes obtaining approvals from Delaware Department of Transportation for the
proposed entrance for the shopping center, as well as approvals from Kent Conservation District for the
Sediment and Stormwater Management Plans for the project. Plans have been approved by all agencies
required. Final Site Plan approval was issued by the City of Dover Planning Office on November 12,
2020.
In accordance with City of Dover Code of Ordinances, we hereby request a one year extension for Site
Development Plan to start authorized construction.
Please do not hesitate to contact us, if you have any questions or comments with regard to the above
request. We appreciate your consideration of this request.
Very truly yours,
DUFFIELD ASSOCIATES, LLC
K. James Taylor, Jr., P.E.
Project Manager
KJT:cpt
12000CA.0421-Dover.COR
Enhancing our community one project at a time. 24
Page 25
Item 5.
MEMORANDUM
Department of Planning & Inspections
P.O. Box 475
Dover, DE 19903
Phone: (302) 736-7010 Fax (302) 736-4217
DATE: April 8, 2021
TO: Planning Commission Members
FROM: Tracey Harvey, Planner
Planning Office
SUBJECT: Revisions to Conditional Use Site Plan C-21-02 JJ’s Learning Experience II
Child Day Care Center at 756 South Little Creek Road, Dover, DE
At its meeting of March 15, 2021, the City of Dover Planning Commission moved to defer action
on Conditional Use Site Plan C-21-02 for thirty (30) days until the next Planning Commission
meeting. This postponement was to allow the applicant to review and formalize to revisions to
the Plan related to safety concerns for the children that will be attending the Child Daycare
Center. As part of the motion, the Planning Commission noted issues involving the lighting,
traffic flow, and children’s access to the playground.
The applicant has submitted revisions to the Conditional Use Site Plan that addresses the
concerns of the Planning Commission. A Letter of Transmittal dated March 25, 2021 and
Revised Plan Sheets C1 and C2 dated March 25, 2021 were received. The key changes/revisions
to the proposed plan consist of the following:
1. Two new pole mounted LED down lights are shown on the Plan to illuminate the east
parking lot.
2. The location of the Dumpster has been repositioned on the Plan to ensure the safety of the
children. The Dumpster with masonry enclosure is now located on the east side of the
east entrance drive and north of a 10-space parking lot area.
3. A pedestrian crosswalk and pedestrian caution sign are shown on the Plan to ensure safe
access to the building entrance. The marked crosswalk leads from the sidewalk along
South Little Creek Road to the east side of the building where the building entrances are
located. A marked crosswalk also connects to the handicapped parking space.
4. A handicap parking space has also been added to the parking lot on the east side of the
building.
5. A bicycle rack has been added near the entry stairs on the east side of the building.
6. Access to the outdoor play area shows access directly from the building to the fenced in
play area; see Sheet C2. There are two doors on the south elevation of the building with
stairs to sidewalk segments to the gate entries to the fenced playground area.
The Development Advisory Committee (D.A.C.) Report and Comments of March 3, 2021 is also
provided as a document of record for this application. The Public Hearing was completed at the
March 15, 2021 Meeting of the Planning Commission; see Meeting Minutes.
25
Page 26
Item 5.
City of Dover
DATA SHEET FOR CONDITIONAL USE REVIEW
DEVELOPMENT ADVISORY COMMITTEE MEETING OF March 3, 2021
PLANNING COMMISSION MEETING OF March 15, 2021
Plan Title: JJ’s Learning Experience 2 Child Day Care Center
C-21-02
Plan Type: Conditional Use Plan
Property Address: 756 South Little Creek Road
Property Location: South side of Little Creek Road opposite Babb Drive
Tax Parcel: ED-05-077.00-01-03.00-000
Owner: Empire Medical Group, LLC
Lessee: Shawanda Johnson
Site Area: 2.39 acres +/-
Proposed Use: Child Day Care Center
Building Size: 10,111 SF tenant space for Day Care Center
33,143 SF total building
Off Street Parking: Required – 36 parking spaces
1 space per 10 children + 1 per adult attendant
Proposed – 60 parking spaces already existing on-site and
13 proposed parking spaces
Sewer & Water: City of Dover
Zoning Classification: C-4 (Highway Commercial Zone)
26
Page 27
C-21-02 JJ’s Learning Experience 2 Child Day Care Center Item 5.
Final DAC Report –March 3, 2021
Page 2
C P
I L
CITYY OF DOVER T A
Y N
DEVELOPMENT ADVISORY COMMITTEE N
O I
APPLICATION REVIEW COMMENTARY F N
G
D.A.C. MEETING DATE: March 3, 2021 D
O
V
E
R
APPLICATION: JJ’s Learning Experience 2 Child Day Care Center
FILE #: C-21-02 REVIEWING AGENCY: City of Dover Planning
CONTACT PERSON: Tracey Harvey, Planner PHONE #: (302) 736-7196
I. PLAN SUMMARY:
The Conditional Use Site Plan Review is to permit the renovation of an existing 10,111 SF space
in an existing one-story 33,143 SF building into a Child Day Care Center to serve 170 children.
The property consists of 2.39 +/- acres and is zoned C-4 (Highway Commercial Zone). The
building is located on the south side of South Little Creek Road opposite Babb Drive. The owner
of record is Empire Medical Group, LLC. and the applicant (lessee) is Shawanda Johnson.
Property Address: 756 South Little Creek Road. Tax Parcels: ED-05-077.00-01-03.00-000.
II. PROJECT DESCRIPTION:
The project proposes using a space in an existing one-story 33,143 SF building. The proposed
location for the Child Daycare Center consists of a 10,111 SF building space that will serve 170
children and 19 adult staff. The plan identifies an outdoor play area that will be fenced in on the
south side of the building. There are two areas of existing pavement to be utilized as parking lots
for a total of 73 spaces on-site. A plan of the site conditions, building architecture sheet, and a
narrative of the proposal were submitted.
A City of Dover Business License and a Public Occupancy Permit are required for the Child Day
Care Center. Child Day Care facilities must meet State licensing standards and must be inspected
by the City of Dover Fire Marshal’s Office.
III. ZONING REVIEW:
The property is zoned C-4 (Highway Commercial Zone). With the proposal, the existing
building footprint is not changing or enlarging. According to Zoning Ordinance Article 5
Section 14.12 a Child Day Care Facility is permitted in all zones provided a need can be
demonstrated. The Child Day Care facilities type of land use requires Conditional Use approval
by the Planning Commission based on the requirements for a Day Care Center when located in a
place other than an unoccupied residence and providing services to more than 13 children. This
27
Page 28
C-21-02 JJ’s Learning Experience 2 Child Day Care Center Item 5.
Final DAC Report –March 3, 2021
Page 3
is noted in Article 5 §14 and Article 10 §1. The requirements for Child Day Care facilities are
given below:
Article 5 Section 14. Child Day care facilities.
14.1 General. In order to promote the development of quality child care outside of the home (day
care facilities), the following two basic assumptions have been made:
14.11 The establishment of child day care services and facilities, wherever there is a
need, is a necessary public objective; and
14.12 Day care programs for children shall be treated as community facilities and shall be
permitted to locate in any zoning district, provided that need has been demonstrated,
state licensing requirements have been met and no physical hazard to children can be
reasonably anticipated.
14.2 Definitions.
Child day care facility. For the purposes of this ordinance, the facilities described furnishing care,
supervision and guidance of a child or group of children unaccompanied by a parent or guardian,
for periods of less than 24 hours per day shall be defined as follows:
14.21 Child day care center.
(a) Any place, other than an occupied residence, which receives children for
compensation for day care or large family day care home; and
(b) Any occupied residence which receives 13 or more children for compensation for
day care.
Child day care centers shall be required to obtain conditional use approval by the
planning
commission in accordance with the procedures and subject to the general conditions set
forth in article 10 and to any specified requirement set forth in subsection 14.3 below,
except in zoning districts where listed as a permitted use.
14.22 Family day care home-children. An occupied residence in which a person provides
care for children other than his/her own family and the children of close relatives for
compensation. Such care in a family day care home is limited to that care given to six or
fewer children with a maximum of three children allowed for after school care. Such child
care facility shall be permitted as an accessory use in all residential zones and shall be
exempt from obtaining a conditional use permit and site plan approval.
14.23 Large family day care home-children. A facility which provides child care for more
than six, but less than 13 children with a maximum of three children allowed for after
school care. This care may be offered in a private home or in a property converted to the
purpose of providing child day care. This form of day care facility requires the submission
of a site plan application in accordance with the procedures and subject to article 10,
section 2 of the zoning ordinance. If a large family day care home is not to be located in
an occupied residence, then a conditional use site plan application shall be required in
accordance with article 10 section 1 of the zoning ordinance.
14.3 Zoning criteria.
14.31 Number of children. Day care centers shall be limited to a maximum of 50 children
in all residential zones.
14.32 Outdoor play area. Must meet the state requirement for day care centers.
14.33 Off-street parking/loading. One space per each adult attendant, plus one space for
28
Page 29
C-21-02 JJ’s Learning Experience 2 Child Day Care Center Item 5.
Final DAC Report –March 3, 2021
Page 4
every ten children.
14.34 Signage for child day care facilities
(a) Signs in residential zones.
i. Family day care homes-children and large family day care homes-
children. One wall-mounted sign limited to two square feet.
ii. Child day care center. One sign, wall-mounted or freestanding, limited
in area to 12 square feet. The planning commission shall consider the
location of such sign as part of the conditional use review and may
approve a lesser amount of sign area if deemed necessary by the
commission to protect the general health, safety and welfare of the public
in general and the residents of the immediate neighborhood in particular.
(b) Signs in nonresidential zones. Child day care centers within nonresidential
zoning districts shall be governed by the sign regulations in effect for the
particular nonresidential zoning district in which the day care center is located.
14.35 Licensing requirements. Child day care facilities must meet state licensing
standards and
must be inspected by the City of Dover Fire Marshal’s Office. A City of Dover Business
License and a Public Occupancy Permit is required.
(Ord. of 5-14-1990; Ord. of 4-25-1994; Ord. of 4-23-2007(3)) Ord. No. 2017-13, 12-11-2017)
Conditional Use Review
This Conditional Use is subject to the requirements of Zoning Ordinance, Article 10 §1 further
discussed below. With Conditional Use applications, the Planning Commission reviews the
proposed project to determine whether or not the intended use is appropriate in type and scale for
the immediate neighborhood. The Commission must also consider whether or not the proposed
use will have an adverse impact on the future orderly development of the surrounding area. The
Planning Commission may prescribe appropriate conditions and safeguards to the use if
determined to be necessary. The following sections of the Zoning Ordinance which relate to the
role of the Commission in reviewing Conditional Use applications are particularly relevant when
reviewing this application:
Article 10 §1:
1.1 Accessibility for emergency response. That all proposed structures, equipment or material shall
be readily accessible for fire, ambulance, police, and other emergency response;
1.2 Harmony of location, size and character. That the proposed use shall be of such location, size
and character that, in general, it will be in harmony with the appropriate and orderly
development of the zone in which it is proposed to be situated and will not be detrimental to the
orderly development of adjacent properties in accordance with the zoning classification of such
properties;
1.3 Residential zones. That, in addition to the above, in the case of any use located in, or adjacent
to, a residential zone:
1.31 The location and size of such use, the nature and intensity of operations involved
in or conducted in connection therewith, its site layout and its relation to access streets
shall be such that both pedestrian and vehicular traffic to and from the use and the
assembly of persons in connection therewith will not be hazardous or inconvenient to, or
incongruous with, the said residential district or conflict with the normal traffic of the
neighborhood; and
29
Page 30
C-21-02 JJ’s Learning Experience 2 Child Day Care Center Item 5.
Final DAC Report –March 3, 2021
Page 5
1.32 The location and height of buildings, the location, nature and height of walls and
fences, the nature and extent of landscaping, and other improvements on the site shall
be such that the use will not hinder or discourage the appropriate development and use
of adjacent land and buildings.
1.4 Conditional use permits.
1.41 Conditional use approval. Any use for which a conditional use permit may be
granted shall be deemed to be a conforming use in the district in which such use is
located, provided that:
(A) The provision in this article under which such permit was issued is still in effect;
(B) Such permit was issued in conformity with the provisions of this article; and
(C) Such permit shall be deemed to affect only the lot or portion thereof for which such
permit shall have been granted.
1.42 Periodic renewal of conditional use permit. The commission may require that
conditional use permits be periodically renewed. Such renewal shall be granted following
public notice and hearing in accordance with subsection 1.53. The commission may
withhold approval of the renewal upon a determination by the city planner to the effect
that such conditions as may have been prescribed by the commission in conjunction with
the issuance of the original permit have not been, or are being no longer, complied with.
If the Planning Commission approves a Conditional Use, the use is granted as a Conditional Use
Permit. Such permits may be permanent, subject to limitations outlined in Zoning Ordinance
Article 10 §1.41 or be required by the Commission to undergo periodic renewal, using the
procedure described in Article 10 §1.42. Any Conditional Use Permit, permanent or not, may be
revoked using the procedure described in Article 10 §1.43 if the conditions prescribed by the
Commission in conjunction with the issuance of the Conditional Use Permit have not been, or
are no longer being complied with.
For a property seeking Conditional Use approval which does not need associated Site
Development Plan approval (due to occupying an existing building), Zoning Ordinance, Article
10 §1.8 outlines the submission requirements. These requirements include a map of the property
showing existing conditions with the appropriate legal data and information on the elements of
the proposed use.
IV. PARKING SUMMARY
The number of required parking spaces for a Child Day Care facility is given in Article 5 §14.33,
which requires one space per ten (10) children plus one space per adult attendant. Since this
facility proposes 170 children and 19 adult attendants, the site would require 36 parking spaces
for the Child Day Care Center use. This size building space in the C-4 zoning district would
require a minimum of 34 parking spaces.
The plan states 73 parking spaces are to be provided in total on the site including 3 handicapped
parking spaces. The plan indicated that 13 proposed new parking spaces will be striped to
achieve the total of 73 spaces. The new spaces are found in both sides of the building. Overall
the 33,143 SF building would require 111 parking spaces; however, it is considered legal non-
conforming as to the current parking requirements.
30
Page 31
C-21-02 JJ’s Learning Experience 2 Child Day Care Center Item 5.
Final DAC Report –March 3, 2021
Page 6
Bicycle Parking
The site is required to provide bicycle parking. The bicycle parking calculation is one (1) for
every twenty (20) parking spaces. Based on the number of parking spaces at the property, a total
of four (4) bicycle parking spaces are required. The location of the bike rack(s) needs to be
located on the Site Plan.
V. SITE CONSIDERATIONS
Access
There is direct access to the site: one to the large parking lot on the west side of the building and
one to the proposed parking areas (previous loading areas) on the east side of the building. There
are two entrances/exits off South Little Creek Road. These entrances must be evaluated by
DelDOT for any necessary improvements.
Dumpsters
Dumpsters for trash and recycling collection are required for the property. The Plan identifies the
two Dumpster locations for the building with a concrete pad and enclosure.
Sidewalks
There is an existing sidewalk and curbing along South Little Creek Road. There is currently no
sidewalk from South Little Creek Road serving as a direct access to the site while it appears to be
shown on the plan. Zoning Ordinance Article 5, Section 18 provides the guidelines for
pedestrian, bicycle, and multi-modal access requirement, which states when sidewalks or other
pathways shall be installed on a property by the property owner or developer. For the Day Care
Center on the east side of the building, the entire parking lot is paved. Access is proposed to the
building with the construction of a ramp and steps on the east side of the building. The Planning
Commission may prescribe appropriate conditions for establishment of the use.
VI. BUILDING ARCHITECTURE
The submission does not require Architectural Elevation drawings since the existing building
will be utilized. The site has an existing one-story stucco-like clad building with a flat roof. The
architectural elevation does not appear to show the improvements for the Child Day Care Center.
For the Child Day Care Center, there are two (2) separate building entrances that both face the
east parking lot. There is an existing entrance for school aged children to enter the building and
there is a proposed new entrance with the constructions of steps and a ramp for entry into the
building.
VII. TREE PLANTING AND LANDSCAPE PLAN
Based on the development area of 10,111 +/- S.F. for the Day Care Center, four (4) trees would
be required to planted on the site. The plan shows the presence of three (3) existing trees and one
(1) tree proposed to be planted. It is noted that the overall site does not comply with the current
tree planting provisions which would require a total of thirty-five (35) trees since it was
developed prior to the Zoning Ordinances current provisions.
31
Page 32
C-21-02 JJ’s Learning Experience 2 Child Day Care Center Item 5.
Final DAC Report –March 3, 2021
Page 7
VIII. CITY AND STATE CODE REQUIREMENTS:
The subject proposal has been reviewed for code compliance, plan conformity, and completeness
in accordance with this agency’s authority and area of expertise. The following items have been
identified as elements which need to be addressed by the applicant:
1) Identify the main entrance to the Child Day Care Center tenant space of the building for
evaluation of pedestrian circulation with the installation of a sidewalk or pavement markings.
2) The data columns will need to be updated prior to Final Approval with the following:
a) Any updates to the data column resulting from changes to the site layout.
b) Any changes recommended, or approvals granted by the Planning Commission.
3) Parking is required for four (4) bicycles. Specifically, the Day Care Center should provide at
least two (2) of these spaces based on their parking requirement. Please identify where the
bicycle parking will be provided and the format of the rack.
4) Provide information on the construction of the Dumpster enclosures.
5) The parking spaces as depicted on the plan must be implemented by striping, signage,
parking bumpers, etc.
IX. RECOMMENDATIONS SUGGESTED AS CONDITIONS OF APPROVAL TO
MEET CODE OBJECTIVES
In accordance with the Zoning Ordinance, Article 10 §1, the Planning Commission in
considering and acting upon Conditional Use Plans may prescribe appropriate conditions and
safeguards so that the public health, safety, and welfare, the comfort and convenience of the
public in general, and the residents of the immediate neighborhood in particular shall be taken
into consideration. These safeguards may to the maximum extent possible further the expressed
intent of the Zoning Ordinance and the accomplishment of several objectives in particular listed
in subsections 1.1 to 1.3. To meet these code objectives, Planning Staff recommends the
Planning Commission prescribe the following conditions and safeguards:
1) Pedestrian Connectivity: To further subsection 1.31 related to pedestrian traffic not being
hazardous or inconvenient to, or incongruous with the neighboring commercial district,
Staff recommends that a delineated pedestrian pathway be marked from South Little
Creek Road to the Day Care Center building entrance. Since the area is paved this may be
achieve by pavement markings.
a. Also add a paved sidewalk to the playground area and ensure accessibility.
2) Parking Facilities: Staff recommends improvements to parking related items.
a. Since the Day Care Center is focused on the eastern portion of the building, it is
recommended that a specific location for staff parking be identified. Full-time
staff parking may need to be located in other areas of the site to allow for the
32
Page 33
C-21-02 JJ’s Learning Experience 2 Child Day Care Center Item 5.
Final DAC Report –March 3, 2021
Page 8
parking for child drop-off/pick-up. The circulation pattern for drop-off and pick-
up should also be identified.
b. A handicapped parking space should be identified on the east side of the building
as there is not a clear accessible path from the handicapped accessible spaces on
the west side of the building.
c. The applicant must identify the location of the bicycle rack on the Plan. It is
recommended that at least two (2) of bicycle parking spaces be provided on the
Day Care Center side of the building.
ADVISORY COMMENTS TO THE APPLICANT:
1) In the event, that major changes and revisions to the Conditional Use Plan occur in the
finalization of the Site Plan contact the Department of Planning and Inspections. Examples
include building additions, relocation of site components, and increases or changes in the
number of children. These changes may require resubmittal for review by the Development
Advisory Committee, Planning Commission, or other agencies and commissions making
recommendations in regard to the plan.
2) Other agencies and departments which participate in the Development Advisory Committee
may provide additional comments related to their areas of expertise and code requirements.
3) Following Planning Commission approval of the Conditional Use Plan, the Plan must be
revised to meet all conditions of approval from the Development Advisory Committee or as
otherwise noted. A Check Print must be submitted for review by Planning Office Staff and to
each DAC participant providing comments. Upon determination that the Plan is complete
and all agency approvals have been received, copies of the Plan may be submitted for final
endorsement.
4) The applicant shall be aware that Conditional Use Plan approval does not represent a Sign
Permit, nor does it convey permission to place any sign on the premises. Any proposed site
or building identification sign shall require a Sign Permit from the City of Dover prior to
placement of any such sign.
5) The applicant shall be aware that Conditional Use Plan approval does not represent a
Building Permit, Business and Occupancy Licenses, and associated construction activity
permits. A separate application process is required for issuance of a Building Permit from the
City of Dover. At a minimum an Administrative Building Permit will be required to
establish this Child Daycare Center facility use in the building. A Fence Permit is required to
construct the playground area fence
If you have any questions or need to discuss any of the above comments, please call the
above contact person and the Planning Department as soon as possible.
33
Page 35
Item 5.
CITY OF DOVER
DEVELOPMENT ADVISORY COMMITTEE
APPLICATION REVIEW COMMENTARY
STAFF D.A.C. MEETING DATE: FEBRUARY 24, 2021
APPLICATION: JJ’s Learning Experience 2 Child Day Care
Center at 756 South Little Creek Road
FILE #: C-21-02
REVIEWING AGENCY: City of Dover Department of Public Works
CONTACT PERSON: Sharon J. Duca, P.E.
CONTACT PHONE #: 302-736-7025
THE SUBJECT PROPOSAL HAS BEEN REVIEWED FOR CODE COMPLIANCE, PLAN CONFORMITY AND COMPLETENESS IN ACCORDANCE WITH THIS AGENCY’S
AUTHORITY AND AREA OF EXPERTISE. THE FOLLOWING ITEMS HAVE BEEN IDENTIFIED AS ELEMENTS WHICH NEED TO BE ADDRESSED BY THE APPLICANT:
CITY AND STATE CODE REQUIREMENTS
STORMWATER / STREETS / SANITATION / GENERAL
1. None.
RECOMMENDATIONS SUGGESTED AS CONDITIONS OF APPROVAL TO MEET CODE OBJECTIVES
STORMWATER / STREETS / SANITATION / GENERAL
1. None.
ADVISORY COMMENTS TO THE APPLICANT
STORMWATER / STREETS / SANITATION / GENERAL
1. The Department of Public Works has no objections to the plan as the site will be serviced by a private trash hauler
and it is located off a State road.
IF YOU HAVE ANY QUESTIONS OR NEED TO DISCUSS ANY OF THE ABOVE COMMENTS, PLEASE CALL THE ABOVE CONTACT PERSON AND THE PLANNING
DEPARTMENT AS SOON AS POSSIBLE.
35
Page 36
CITY OF DOVER Item 5.
DEVELOPMENT ADVISORY COMMITTEE
APPLICATION REVIEW COMMENTARY
STAFF D.A.C. MEETING DATE: FEBRUARY 24, 2021
APPLICATION: JJ’s Learning Experience 2 Child Day Care Center at 756
South Little Creek Road
FILE #: C-21-02
REVIEWING AGENCY: City of Dover Department of Water & Wastewater
CONTACT PERSON: Jason A. Lyon, P.E., Director of Water & Wastewater
CONTACT PHONE #: 302-736-7025
CONTACT PHONE #: jlyon@dover.de.us
T HE S UBJECT P ROPOSAL HAS BEEN R EVIEWED FOR C ODE C OMPLIANCE , P LAN C ONFORMITY AND C OMPLETENESS IN A CCORDANCE WITH THIS
A GENCY ’ S A UTHORITY AND A REA OF E XPERTISE .
T HE F OLLOWING I TEMS HAVE BEEN I DENTIFIED AS E LEMENTS W HICH N EED TO BE A DDRESSED BY THE A PPLICANT :
CITY AND STATE CODE REQUIREMENTS
WATER
1. Our office has no objection to the conditional use proposed for the subject property.
2. Due to the fact that this property is changing uses, water usage projections (peak demand or plumbing fixtures) must be submitted
to our office to correctly determine the size of the domestic and irrigation (if applicable) water meter for the building. These
projections must be submitted prior to approval so the meter size can be placed on the final site plan, if an upgrade is required.
The proposed water meter must be installed in a pit per City of Dover requirements and manufacturer’s recommendations. Also,
a dual check valve is required downstream of the meter.
WASTEWATER
1. Our office has no objection to the conditional use proposed for the subject property.
2. Sizing (flow) calculations must be submitted for all sanitary sewer laterals (other than for single-family dwellings) showing that
velocity and all other requirements are met. All proposed wastewater utility components must meet the requirements of the
Public Utilities Water Wastewater Handbook, effective date March 22, 2010. Please contact our office for more information.
GENERAL
1. None.
RECOMMENDATIONS SUGGESTED AS CONDITIONS OF APPROVAL TO MEET CODE OBJECTIVES
WATER / WASTEWATER / GENERAL
1. None
ADVISORY COMMENTS TO THE APPLICANT
WATER
1. Water impact fees may be associated with this project.
2. One meter shall be utilized for the entire building.
WASTEWATER
1. Wastewater impact fees may be associated with this project.
I F Y OU H AVE A NY Q UESTIONS OR N EED TO D ISCUSS ANY OF THE A BOVE C OMMENTS , P LEASE C ALL THE A BOVE C ONTACT P ERSON AND THE
36
P LANNING D EPARTMENT AS S OON AS P OSSIBLE .
Page 37
Item 5.
CITY OF DOVER ELECTRIC
DEVELOPMENT ADVISORY COMMITTEE
APPLICATION REVIEW COMMENTARY
STAFF D.A.C. MEETING DATE: FEBRUARY 24, 2021
APPLICATION: JJ’s Learning Experience 2 Child Day Care Center at 756 S.
Little Creek Rd
FILE #: C-21-02
REVIEWING AGENCY: City of Dover Electric Department
CONTACT PERSON: Paul Waddell, Electric Director
CONTACT PHONE #: 302-736-7072
CONTACT EMAIL: pwaddell@dover.de.us
T HE S UBJECT P ROPOSAL HAS BEEN R EVIEWED FOR C ODE C OMPLIANCE , P LAN C ONFORMITY AND C OMPLETENESS IN A CCORDANCE
WITH THIS A GENCY ’ S A UTHORITY AND A REA OF E XPERTISE .
T HE F OLLOWING I TEMS HAVE BEEN I DENTIFIED AS E LEMENTS W HICH N EED TO BE A DDRESSED BY THE A PPLICANT :
CITY AND STATE CODE REQUIREMENTS
ELECTRIC
1. Any relocation of existing electrical equipment will be engineered by the City of Dover Electric Department. Developer
may be required to perform a quantity of the relocation. Any work performed by the City of Dover will be at the
owner’s expense.
2. Owner is responsible for locating all existing underground facilities to include electric, water and gas.
3. Owner is responsible for site and/or street lighting.
4. Must maintain 10' clearance around all electrical equipment, unless pre-approved by the City of Dover Electric
Engineering Department.
5. Prior to the completion of any/all designs and estimates, the owner is responsible for providing the Electric
Engineering Department with a physical address of the property.
6. All Engineering and design for Dover Electric will be engineered upon receipt of final approved plans. All Engineering
work will be furnished by the City’s Electric Engineering Department.
GENERAL
1. Final site plan must be submitted in a digital format compatible with AutoCAD 2010 (.dwg format) and Adobe Reader
(.pdf format), if applicable.
RECOMMENDATIONS SUGGESTED AS CONDITIONS OF APPROVAL TO MEET CODE OBJECTIVES
37
Page 38
JJ’s Learning Experience 2 Child Day Care Center at 756 S. Little Creek Rd Item 5.
File #: C-21-02
February 24, 2021
Page 2 of 2
1. Owner must give the City of Dover Electric Department three (3) months’ notice prior to construction. Owner is
responsible for following the requirements outlined in the City of Dover’s Electric Service Handbook. The handbook
is now available on the website at the following link: https://evogov.s3.amazonaws.com/media/27/media/13108.pdf.
ADVISORY COMMENTS TO THE APPLICANT
1. Provide load sheets as soon as possible for proper sizing of transformers and creation of primary fee estimates.
Current load sheets can be found at the following link:
https://www.cityofdover.com/media/Electric%20Department/COD%20Electric%20Load%20Sheet.pdf.
2.
I F Y OU H AVE A NY Q UESTIONS OR N EED TO D ISCUSS ANY OF THE A BOVE C OMMENTS , P LEASE C ALL THE A BOVE C ONTACT P ERSON
AND THE P LANNING D EPARTMENT AS S OON AS P OSSIBLE .
38
Page 39
C F
C-21-02
Item 5.
I I
T R
CITY OF DOVER Y E
DEVELOPMENT ADVISORY COMMITTEE O M
F A
APPLICATION REVIEW COMMENTARY
R
D.A.C. MEETING DATE: 02/24/21 D S
O H
V A
E L
APPLICATION: Learning Experience 2 Child Care at 756 S Little Creek Rd
R
FILE #: C-21-02 REVIEWING AGENCY: City of Dover, Office of the Fire Marshal
CONTACT PERSON: Jason Osika, Fire Marshal PHONE #: (302) 736-4457
THE SUBJECT PROPOSAL HAS BEEN REVIEWED FOR CODE COMPLIANCE, PLAN CONFORMITY, AND
COMPLETENESS IN ACCORDANCE WITH THIS AGENCY’S AUTHORITY AND AREA OF EXPERTISE.
THE FOLLOWING ITEMS HAVE BEEN IDENTIFIED AS ELEMENTS WHICH NEED TO BE ADDRESS BY THE
APPLICANT:
CITY AND STATE CODE REQUIREMENTS:
1. Proposed occupancy classification is daycare center.
NFPA 101, A.16.1.1 Suggested Staff to Client Ration in New and Existing Day-Care Occupancies
Staff to Client Ratio Age (months)
1:3 0-24
1:4 25-36
1:7 37-60
1:10 61-96
1:12 97 plus
1:3 Clients incapable of self-preservation
If staff to client ratios are below those suggested above, the AHJ shall determine the additional
safeguards (this may include restricting the daycare to level of exit discharge only, requiring additional
smoke detection, requiring automatic sprinkler protection, requiring better or additional means of
egress, requiring similar types of provisions depending on the situation).
NFPA 101, 3.3.190.4 Day Care Occupancy. An occupancy in which four or more clients receive care,
maintenance, and supervision, by other than their relatives or legal guardians, for less than 24 hours per
day.
NFPA 101, 16.6.1.4.1.1 Family Day Care Home. A family day care home shall be s day care home in which
more than three, but fewer than seven, clients receive care, maintenance, and supervision by other than
their relatives or legal guardians for less than 24 hours per day, generally within a dwelling unit.
NFPA 101, 16.6.1.4.1.2 Group Day Care Home. A group daycare home shall be a day care home in which
not less than 7, but not more than 12, clients receive care, maintenance, or supervision bu other than their
relatives or legal guardians for less than 24 hours per day, generally within a dwelling unit.
NFPA 101, 3.3.66 Dwelling Unit definitions
39
Page 40
Item 5.
2. Building Access shall be no further than 50 feet from a primary entrance
Where buildings are provided with an automatic sprinkler system installed in accordance with
NFPA 13, access shall be no further than 100 feet from the primary entrance.
(2015 Delaware State Fire Prevention Regulations, 705, Chapter 5, 3)
3. Parking shall be prohibited in front of the primary entrance for a width of not less than 1.5 times
the width of the door(s) or for 10 feet, whichever is greater.
(2015 Delaware State Fire Prevention Regulations, 705, Chapter 5, 6.3.2)
4. Perimeter access shall be 50% and clearly shown on the plans.
Perimeter Access minimum width shall be 15 feet measured from the face of the building at grade
with a maximum slope of ten percent (10%). Plantings and utility services (includes condenser
units, transformers, etc.) shall be permitted within the perimeter access, and shall not interfere
with emergency services fire ground operations.
If a physical barrier (fence, pond, steep slope, etc) prevents access, that portion of the building
perimeter shall not be included in the calculation of Percent of Perimeter Access.
(2015 Delaware State Fire Prevention Regulations, 705, Chapter 5, 3)
5. Fire lanes shall cover 25% of the proposed building.
Fire lanes are required to be 24 feet wide and run along the front of the building as determined by
the primary entrance(s). In cases where there is more than one primary entrance(s), each shall be
served by a fire lane even if this exceeds the percentage as required.
The closest edge of fire lanes shall not be located closer than ten (10) feet to the exterior wall and
the closest edge of fire lanes shall not be located further than 50 feet from the exterior wall if one
or two stories in height; 40 feet if three or four stories in height, or 30 feet if over four stories in
height.
(2015 Delaware State Fire Prevention Regulations, 705, Chapter 5)
6. Where parking is located between the building and the fire lane, parking shall not be located
closer than 15 feet to the exterior wall.
(2015 Delaware State Fire Prevention Regulations, 705, Chapter 5, 6.4.1)
7. All Fire Lanes shall be marked as follows:
both the inner and outer edges of the fire lane shall be marked, where curbs are present, the top
and face of the curb shall be painted yellow, where no curbs are present, a four inch (4”) solid
yellow demarcation line shall mark the edge(s) of the fire lane.
(2015 Delaware State Fire Prevention Regulations, 705, Chapter 5, 7)
8. The specific color yellow shall be the uniformly accepted yellow as utilized by State of Delaware
Department of Transportation (DelDOT). Only vivid and durable paint shall be used and shall be
suitable for street surfaces
9. Fire lane signs shall be located as follows:
see Figure 5-16 – Approved Sign For Marking Fire Lanes, fire lane signs shall be spaced at 150
foot intervals maximum, all fire lane signs shall be located no less than six feet (6’) and no higher
than eight feet (8’) above the pavement, signs shall be placed at each end of the fire lane, and
signs shall face all oncoming traffic.
40
Page 41
Item 5.
Where parking is not restricted roadway markings shall utilize the words "FIRE" and "LANE" in
lieu of fire lane signs and shall conform to the specifications of 7.6.
(2015 Delaware State Fire Prevention Regulations, 705, Chapter 5, 7)
10. Where overhangs, canopies, balconies, or any other building or site features must project over
any fire lane, an unobstructed vertical clearance of not less than 13’-6” above the fire lane shall be
provided and the portion of the building perimeter which contains overhangs, canopies,
balconies, or any other building features shall not apply towards the fire lane accessibility
requirements of Section 4.0, Table 5-1 in this chapter.
(2015 Delaware State Fire Prevention Regulations, 705, Chapter 5, 6.8)
11. Multiple Access Roads shall be provided when a fire department access road (fire lane) is
determined by the Fire Marshal to be impaired by vehicle congestion, condition of terrain,
climatic conditions, or other factors that could limit access such as placement of fire hose from
fire equipment.
12. Street width shall be in accordance with City of Dover Code of Ordinances, Appendix A, Article
VII, Section A. 13,
Residential areas
24 feet wide with no parking,
30 feet wide with parking on one side, or
36 feet wide with parking on both sides
Commercial areas
26 feet wide with no parking,
32 feet wide with parking on one side, or
38 feet wide with parking on both sides
Alley
12 feet wide
Any dead-end road more than 300 feet in length shall be provided with a turnaround or cul-de-
sac as outlined in the 2015 Delaware State Fire Prevention Regulations 705, chapter 5, 2.3.
13. Speed Reduction Devices must be approved, please see City of Dover Ordinance Chapter 98-10 in
reference to this process.
14. Gated Areas: Fire Department access shall be provided to the property through the use of a
system or device approved by the Fire Marshal. The system or device required shall be located in
an area accessible to the fire department and approved by the Fire Marshal. All gates shall be
either automatic or manual.
An automated system shall consist of one manual and one automated means to open the gate.
The owner or their representative shall meet with the Fire Marshal prior to submission to agree
on the system. A letter of agreement shall be created and signed by both parties. The letter shall
include a detailed description of both the manual and automated means.
A manual gate shall consist of one manual means to open the gate. The owner or their
representative shall meet with the Fire Marshal prior to submission to agree on the means to
open. A letter of agreement shall be created and signed by both parties. The letter shall include a
detailed description of the manual means to open.
41
Page 42
Item 5.
To be considered accessible for fire department apparatus the actual clear openings shall be not
less than 14 feet, the paved surface through the gate shall be not less than 12 feet, and the gate
shall be setback from the perpendicular street by at least 50 feet.
Please contact this office to discuss options available to comply with this requirement.
(2015 Delaware State Fire Prevention Regulations 705, Chapter 5, 2.6)
15. All fire hydrants shall be marked as prescribed within the appropriate section of this regulation
and as illustrated by the appropriate figures of this regulation.
All fire hydrants shall have minimum of four-inch (4") solid yellow demarcation lines to define
specific areas, where fire hydrants are located along a curb line with permitted parking, the area
between the fire hydrant and the street or fire lane shall be stenciled with four inch (4")
demarcation lines and the words "NO PARKING", demarcation lines shall be measured from the
center line of the fire hydrant and extend for a distance 15 feet on both sides.
Where fire hydrants are located in parking lots or other areas susceptible to blockage by parked
vehicles they shall be treated as follows: fire hydrants shall be protected in all directions for a
distance of seven feet (7') with barriers or curbing, Minimum four-inch (4") diameter steel
bollards filled with concrete and marked yellow shall be installed at the outermost corners of the
fire hydrant demarcation area. The minimum height of the bollard shall be 36 inches above the
finished grade of the adjacent surface, and the steamer connection of all fire hydrants shall be
positioned so as to be facing the edge of the street, or traffic lane.
(2015 Delaware State Fire Prevention Regulations, 705, Chapter 6, 2)
The owner is responsible if the hydrant is private.
16. Hydrant barrels shall be provided with reflective material, such as paint, durable for
highway/roadway markings or a reflective tape of a minimum of 2” in width around the barrel
under the top flange, hydrant bonnets shall be color coded based on the following criteria: class
AA 1500 GPM - painted light blue, class A 1,000 GPM -1499 GPM - painted green, class B 500 -
999 GPM - painted orange, class C 250 - 499 GPM - painted red, class D under 250 GPM -
painted black.
(2015 Delaware State Fire Prevention Regulations 703, Chapter 3. 4)
The owner is responsible if the hydrant is private.
17. NFPA 72 compliant Fire Alarm System required per occupancy code requirements.
Fire alarm in place of assembly. Fire alarm required. Any new occupancy or new portion of an
occupancy determined to be a place of assembly by the fire marshal and is capable of receiving an
occupant load of 75 persons or greater, shall be required to install a fire alarm in accordance with
NFPA codes governing the installation of fire alarms and the National Electrical Code.
Fire alarm system required. Any existing occupancy or portion of an existing occupancy determined
to be a place of assembly by the fire marshal, and is undergoing renovations in excess of 50
percent of the assessed value of the building and is capable of receiving an occupant load 75
persons or greater or is being enlarged to receive an occupant load of 75 persons or greater, shall
be required to install a complete fire alarm system in accordance with NFPA codes governing the
installation of fire alarms and the National Electrical Code.
Public mode audible requirements. To ensure that audible public mode signals are clearly heard by
occupants of a structure, they shall have a sound level at least 15 decibels (dB) above the average
ambient sound level or five decibels (dB) above the maximum sound level having a duration of at
least 60 seconds, whichever is greater, measured five feet (1.5m) above the floor in the area
42
Page 43
Item 5.
required to be served by the system using the A-weighted scale dBA. In the event the stated
requirement cannot be met a shunt trip relay/switches shall be the approved method of meeting
the intent of this section of the Code.
(City Code of Ordinances 46-171)
18. Sprinkler system required. System is to be monitored by an approved Fire Alarm System.
This chapter shall apply to all buildings, structures, marine vessels, premises, and conditions
which are modified by more than 50% after the effective date of these Regulations. The 50%
figure shall be calculated utilizing the gross square footage of the building, structure, marine
vessel, premises and conditions as to arrive at the correct application.
Any proposal that is presented to the Office of the State Fire Marshal for review and approval for
a building rehabilitation as defined in the 101 Life Safety Code, for less than 50% of the gross square
footage of a non-sprinklered building, may not have another such project for the same building submitted
for review and approval any sooner than three (3) years after the date of the final inspection unless
sprinkler projection is provided throughout the entire building.
In all buildings exceeding 10,000 square feet of aggregate, gross floor area.
In all buildings in excess of 40 feet in height or more than four (4) stories in height.
In all buildings or areas thereof used for the storage, fabricating, assembling, manufacturing,
processing, display or sale of combustible goods, wares, merchandise, products, or materials when more
than two (2) stories or 25 feet in height.
In all basement areas exceeding 2,500 square feet floor area.
In residential occupancies when of: Type V (0,0,0) or Type III (2,0,0) construction and exceeding
two (2) stories or 25 feet in height. Type V (1,1,1) and Type III (2,1,1) or
Type IV (2,H,H) construction exceeding three (3) stories or 3In all residential apartment
buildings storage areas except individual unit closets that are located within individual residential living
units.
In all buildings used as health care occupancies as defined in the Life Safety Code, NFPA 101, as
adopted and/or modified by these Regulations. In all buildings or areas classified as "high hazard" under
the Life Safety Code, NFPA 101, or "extra hazard" under the Standard for the Installation of Sprinkler
Systems, NFPA 13, as adopted and/or modified by these Regulations.
All buildings used as dormitories, in whole or in part, to house students at a public or private
school or public or private institution of higher education. (16 Del.C. Ch. 88) This applies to all such
dormitories regardless if new or existing.
(2015 State of Delaware fire Prevention Regulations, 702, Chapter 4)
Places of assembly shall be sprinklered throughout in accordance with the most recently adopted
edition of NFPA 13 when the following apply:
All new indoor places of assembly with an occupant load of 150 persons or greater.
Any interior renovations of 50 percent or more to an existing place of assembly with an occupant
load greater than 150 persons.
Any additions or increase in interior size to an existing place of assembly that would create an
occupant load of 150 persons or greater.
Places of assembly where alcohol is served for consumption on the premises shall be sprinklered
throughout in accordance with the most recently adopted edition of NFPA 13 when the following
apply:
All new indoor places of assembly with an occupant load of 100 persons or greater and where
alcohol will be served for consumption on the premises.
43
Page 44
Item 5.
Any interior renovation of 50 percent or more to an existing place of assembly with an occupant
load greater than 100 persons and where alcohol will be served for consumption on the premises.
Any additions or increase in interior size to an existing place of assembly which would create an
occupant load of 100 persons or greater and where alcohol will be served for consumption on the
premises.
New educational occupancies of 5,000 square feet or greater shall be sprinklered throughout in
accordance with the most recently adopted edition of NFPA 13.
(City of Dover Code of Ordinances 46-162)
19. Fire Department Connection is to be a 5-inch stortz connection on a 30-degree elbow located
within 50 feet of main entrance. Access to the Fire Department Connection must be clear
unobstructed access as defined by the AHJ.
Fire department connections. Unless otherwise approved by the fire marshal, fire department
connections shall be on the street side of the building and shall be located and arranged so that
hose lines can be readily and conveniently attached to without interference from any nearby
obstructions as defined by the fire marshal's office. Fire department connections shall be a five-
inch Storz. Fire department connections shall be within 300 feet of an approved City of Dover
Fire Hydrant and within 50 feet of the main entrance of the structure it serves. All fire
department connections shall be not less than three feet nor more than five feet in height above
finished grade. The fire marshal shall have the authority to require more stringent
requirements when deemed necessary. (City of Dover Code of Ordinances 46-162)
20. Parking and/or obstructions shall be prohibited in front of fire department connections for a
distance measuring from the center line and extending four feet on both sides.
(2015 Delaware State Fire Prevention Regulations, 705, Chapter 5, 6.3.4)
21. Fire Department Connection to be located within 300 feet of fire hydrant, measured as hose
would come off the fire equipment.
22. All standpipe and sprinkler connections shall be marked as prescribed within the appropriate
section of this regulation and as illustrated by the appropriate figures of this regulation. All
standpipe and sprinkler connections shall have minimum of four inch (4") solid yellow
demarcation lines to define specific areas, Solid yellow demarcation lines shall be measured from
the center line of the connection and extend for a distance of four feet (4') on both sides, and
where parking is allow between the building and the street or fire lane the solid yellow
demarcation lines shall extend from the end of the sidewalk surface to the street or fire lane
(Markings shall not be required on the sidewalk surface). All fire department connections
(standpipe and sprinkler) shall have a minimum 12" x 18" sign that reads FIRE DEPT.
CONNECTION, sign lettering shall be a minimum of 3 inches (3") in height with red scotchlite
letters on white scotchlite background. The sign shall be clearly visible from the fire lane or
roadway, and signs using NFPA international symbols shall be an acceptable alternative. (2015
Delaware State Fire Prevention Regulations, 705, Chapter 6, 3)
23. Standpipes shall be provided in all areas and buildings as required in the codes and standards
listed in Regulation 701 as well as the following areas or buildings:
In all Class A and Class B places of assembly and institutional occupancies two (2) stories or 25
feet in height or over,
In any building over three (3) stories, In any building over 35 feet in height,
44
Page 45
Item 5.
In any building that has a floor above the first floor over 10,000 square feet gross floor area,
In all buildings where the 1st floor exceeds 60,000 gross square feet,
a Class I horizontal standpipe system installed in accordance with the applicable codes and
standards listed in Regulation 701 of these Regulations shall be provided. All standpipe systems
shall be installed in accordance with the applicable codes and standards listed in Regulation 701.
The standpipe system shall be carried up with each floor and shall be installed and ready for use
as each floor progresses.
Standpipes shall not be more than one floor below the highest forms of staging,
The 2½-inch of hose connections on Class I systems shall be provided in the following locations,
At the highest intermediate landing between floor levels in every required exit stairway,
Where intermediate landing is not provided, hose connections shall be permitted to be located at
the main floor landings in exit stairways when approved by the authority having jurisdiction,
Where the local fire department has the capability of providing the required pressure,
hydraulically designed standpipe systems in fully sprinklered, non-high-rise buildings shall be
designed to provide the required waterflow rate.
A sign shall be provided at each landing, in all interior stairways, designating the floor level.
(2015 Delaware State Fire Prevention Regulations 702, Chapter 4, 2)
24. The installation of natural gas and LP gas meters, regulators, valves, and LP gas bottles shall be
protected from impact damage by impact protection. Natural gas and LP gas meters, regulators,
and valves located inside structures shall have impact protection, except when located in
separate protected utility rooms.
Dimensions of bollards. Bollards shall be a minimum of six-inch diameter filled with concrete. The
bollard shall be set into the ground at a depth of at least 36 inches (three ft.) embedded in
concrete at a minimum of 18 inches surrounding the bollard. The bollards must be a least 48
inches (four ft.) in height above the finish grade elevation. Any deviation of the stated
requirements must be approved by the fire marshal and/or chief building inspector. The above
dimensions shall serve as the requirement for installation; however, the fire marshal and/or chief
building inspector shall have the authority to require more stringent dimensions to fit the needs
of devices warranting impact protection.
Color of bollards. Bollards should be of the following colors; yellow, amber or orange. All colors
shall be of fluorescent or have a reflective coating. Any deviation of the stated requirements must
be approved by the fire marshal and/chief building inspector.
(City of Dover Code of Ordinances, 46-4)
25. Every house, building or structure used or intended for use as living quarters or as a place for
conducting business, and having any wall facing or abutting any public or private street or alley,
shall have displayed on that wall, in legible, easily read characters which are of contrasting color
to the background, the proper street number for such house, building, or structure in accordance
with the following:
One-family and two-family residential structures, height, the number shall measure a minimum of four
inches in height, location, the number shall be placed on the house above or to the left or right of
45
Page 46
Item 5.
the front entrance, color, the number shall be contrasting to the background color, Arabic numerals,
all numbers shall be Arabic numerals.
Multiple-family dwellings, measurements, the number shall measure a minimum of six inches when
identifying individual apartments with exterior doors, and 12 inches when identifying buildings
with apartment complexes where there are two or more buildings not assigned street addresses.
Individual buildings with street addresses shall have numbers measuring six inches, location,
numbers shall be placed either in the center of the building or on the street end of the building so
as to be visible from either the public or private street or from the parking lot, color, numbers shall
be contrasting to the background color, Arabic numerals, all numbers used shall be Arabic
numerals.
Commercial, industrial and office buildings, height, the numbers shall measure a minimum of 12 inches in
height, location generally, numbers shall be placed either in the center of the building or on the
street end of the building so as to be visible from either the public or private street or from the
parking lot,
property line or driveway, should the building be located far enough from a public or private road so
that the numbers are not clearly visible from the street, then the street address shall also be
posted on the property at or near the property line or driveway to said building,
color; each building, numbers shall be contrasting to the background color and shall be placed on
each building in the complex,
Arabic numerals, all numbers used shall be Arabic numerals,
Shopping centers. Shopping centers consisting of two or more stores shall have a tenant or suite
number affixed to the front of the tenant space and on the outside of the rear door which
corresponds with that tenant space. Numbers shall measure six inches in height.
(City of Dover Code of Ordinances, 98-344)
26. A lock box (Knox) containing any and all means necessary for fire department access shall be
provided at the following occupancies: any occupancy that contains a fire alarm signaling system
that is monitored off-site, or any occupancy that contains an automatic sprinkler system.
(2015 Delaware State Fire Prevention Regulations 705, Chapter 5, 2.4)
Secured key systems. When required; exemption. A secured key system shall be required for any new
or existing building where a fire alarm or sprinkler system is being installed. It shall be the
responsibility of the owner or occupant to keep a set of keys in the secured key box that are
current to the locks of the protected occupancy. Buildings with 24-hour staffing or guard
service shall be exempt from this subsection.
Location. The secured key system shall be located as close to the main entrance as possible.
Should the building design not allow the secured key system to be located by the main
entrance, the fire marshal and fire chief shall come to an agreement as to an alternate
location for the key box. A secured key system, once installed, shall not be obstructed from
view or obstructed by any means that would delay the fire department access to the box.
Required keys. Keys to be secured in the key box shall include keys to all points of ingress or
egress, whether on the interior or exterior of the building, and keys to locked mechanical
rooms, electrical rooms, elevator rooms, fire alarm and sprinkler controls and any area
46
Page 47
Item 5.
protected by automatic fire detection. Keys to individual residential apartment units are not
required.
Ordering responsibility. It shall be the responsibility of the general contractor to order the key
box for new buildings. It shall be the responsibility of the owner or tenant to order the key
box for existing buildings.
Installation before testing. No acceptance test for sprinklers or fire alarms shall be conducted
before the installation of a key box.
(City Code of Ordinances 46-127)
Knox Box to be mounted 6 feet above ground level
27. All required means of egress shall have an exit discharge consisting of a non-slip surface and
leading to and terminating at a public way.
28. Project to be completed per approved Site Plan.
29. Full building and fire plan review is required.
30. Separate building permits/plans submission will be required for each building and/or tenant fit
out. If the permit submission is for a “shell” a Certificate of Occupancy will not be issued.
Separate plans and permits submissions will be required for each “tenant fit out” at which time a
Certificate of Occupancy will be issued upon compliance/completion of each “tenant fit out”.
Each “shell” will require a fire permit for sprinkler and fire alarm if applicable. Those systems (for
the “shell”) must be accepted into service prior to any “tenant fit out” fire permits being issued.
31. Construction or renovations cannot be started until building plans are approved.
32. Fire alarm systems, fire suppression systems, hoods, exhaust ducts, and hood suppression
systems require a fire permit from the Fire Marshal’s Office. This work cannot be started until
the permit is approved.
33. Building cannot be occupied by the public until a Certificate of Occupancy is obtained.
ADDITIONAL / SPECIFIC REQUIREMENTS TO OBTAIN APPROVAL:
1. State of Delaware Daycare Licensing approval is needed
2. State of Delaware Public Health approval is needed
3. Confirm that the Fie Lane is at least 10’ from the building
APPLICABLE CODES LISTED BELOW (NOT LIMITED TO):
2015 NFPA 1 Fire Code (NFPA; National Fire Protection Association)
2015 NFPA 101 Life Safety Code (NFPA; National Fire Protection Association)
2013 NFPA 72 National Fire Alarm and Signaling Code (NFPA; National Fire Protection Association)
2013 NFPA 13 Installation of Sprinkler Systems (NFPA; National Fire Protection Association)
2009 IBC (International Building Code)
Latest editions of all other NFPA Codes as defined by the Delaware State Fire Prevention Regulations
2015 Delaware State Fire Prevention Regulations
City of Dover Code of Ordinances
*If you have any questions or need to discuss any of the above comments, please call the above
contact person listed.
47
Page 48
Item 5.
CITY OF DOVER D
E
DEVELOPMENT ADVISORY COMMITTEE
L
APPLICATION REVIEW COMMENTARY D
O
T
===============================================================
APPLICATION: JJ’s Learning Experience (756 South Little Creek Road)
FILE#: C-21-02 REVIEWING AGENCY: DelDOT
CONTACT PERSON: Joshua Schwartz PHONE#: 302-760-2768
===============================================================
THE SUBJECT PROPOSAL HAS BEEN REVIEWED FOR CODE COMPLIANCE, PLAN CONFORMITY AND COMPLETENESS IN
ACCORDANCE WITH THIS AGENCY'S AUTHORITY AND AREA OF EXPERTISE.
THE FOLLOWING ITEMS HAVE BEEN IDENTIFIED AS ELEMENTS WHICH NEED TO BE ADDRESSED BY THE APPLICANT:
CITY & STATE CODE REQUIREMENTS:
No person, firm, corporation or the like shall construct, open, reconstruct, maintain, modify or use any
crossing or entrance onto a state-maintained highway, street or road, including any drainage modifications
leading into or carried by the highway drainage system, without first having complied with standards and
regulations adopted by the Department and having obtained a permit issued by the Department.
Please contact the Delaware Department of Transportation - Development Coordination section to begin
permit process.
RECOMMENDATIONS SUGGESTED AS CONDITIONS OF APPROVAL TO MEET CODE
OBJECTIVES:
ADVISORY COMMENTS TO THE APPLICANT:
1. Schedule a pre-submittal meeting through DelDOT Subdivisions.
2. At a minimum a Record Plan approval will be required.
48
Page 49
KENT CONSERVATION DISTRICT
Item 5.
1679 SOUTH DUPONT HIGHWAY • DOVER, DELAWARE 19901• (302) 608-5370 • WWW.KENTCD.ORG
CITY OF DOVER
DEVELOPMENT ADVISORY COMMITTEE
APPLICATION REVIEW COMMENTARY
February 24, 2021
APPLICATION: JJ’s Learning Experience 2 Child Day Care Center at 756 South Little Creek Road
FILE #: C-21-02
REVIEWING AGENCY: Kent Conservation District
CONTACT PERSON: Katherine Owens PHONE #: 302-608-5370
THE SUBJECT PROPOSAL HAS BEEN REVIEWED FOR CODE COMPLIANCE, PLAN
CONFORMITY AND COMPLETENESS IN ACCORDANCE WITH THIS AGENCY’S AUTHORITY
AND AREA OF EXPERTISE. THE FOLLOWING ITEMS HAVE BEEN IDENTIFIED AS
ELEMENTS WHICH NEED TO BE ADDRESSED BY THE APPLICANT:
Source: 2019 Delaware Sediment and Stormwater Regulations
CITY AND STATE CODE REQUIREMENTS:
Kent Conservation District has no objection to the conditional use site plan for the above referenced site.
ADVISORY COMMENTS TO THE APPLICANT:
If at any time expansion or soil disturbance (e.g. clearing, grading, excavations, tree clearing, or stoning)
exceeds 5,000 square feet, a Sediment and Stormwater Management Plan shall be submitted and approved by
the Kent Conversation District.
49
Page 50
Item 5.
REVISIONS BY
1
CONDITIONAL USE SITE PLAN DATA COLUMN: 1 3-25-2021 MAS
1 DOVER PLANNING
C2 DAYCARE NAME: JJ'S LEARNING EXPERIENCE 2 COMMISSION COMMENTS
ADDRESS: SUITE I, 756 SOUTH LITTLE CREEK ROAD
DOVER, DELAWARE 19901
HOURS & DAYS OF OPERATION: MONDAY -- FRIDAY 5:45 AM TO 7:00 PM
SATURDAY 7:00 AM TO 12:00 PM
SUNDAY CLOSED
OWNER'S NAME
AND ADDRESS: EMPIRE MEDICAL, LLC
1100 LA GRANGE PARKWAY, NEWARK, DE 19702
REPRESENTED BY MOHAMMED CHAUDRY
TAX MAP NUMBER: ED-05-O77.00-01-030.000-000
10 LOT AREA: 2.39 ACRES
EXISTING
PARKING ZONING: C4
OCCUPANCY TYPE: PROPOSED GROUP I-4 DAYCARE
BUILDING AREA: 33,143 S.F., EXISTING
DAYCARE AREA: 10,111 S.F. PROPOSED DAYCARE
CHANGE TO IMPERVIOUS: NEW CONCRETE DUMPSTER PAD - 211 S.F.
1
UP
(2) NEW STAIRS TO GRADE - 84 S.F.
SIDEWALK ON SOUTH SIDE - 472 S.F.
SIDEWALK ON NORTH SIDE - 1,262 S.F.
TOTAL NEW IMPERVIOUS - 2,029 S.F.
NUMBER OF CHILDREN: 170 CHILDREN
SUITE I
7
PROPOSED NUMBER OF ADULTS: 19 ADULTS
PP EXISTING
DAY CARE 1
PARKING PROPOSED 10,111± S.F.
PARKING REQUIRED PARKING: 170 CHILDREN ÷ 10 CHILDREN PER SPACE = 17 PARKING SPACES
3 19 ADULTS ÷ 1 ADULT PER SPACE = 19 PARKING SPACES
TOTAL REQUIRED = 36 PARKING SPACES
BIKE RACK REQUIRED FOR MINIMUM 2 BIKES
ACTUAL PARKING: EXISTING PLUS PROPOSED: 73 SPACES, INCLUDING 4 ACCESSIBLE SPACES. ONE
ACCESSIBLE SPACE IS LOCATED IN THE EAST PARKING LOT. BIKE RACK FOR 5 BIKES LOCATED
ON PLAN AND SPECIFIED ON C2. DROP OFF AREA IS SHOWN ON PLAN AND DOTTED SKIPS LINES
FH SHOW EXIT FROM THE DROP-OFF AREA INTO A K-TURN. 11 DESIGNATED STAFF PARKING
SOUTH LITTLE CREEK ROAD
SPACES ARE SHOWN. DIRECT ACCESS TO PLAYGROUND VIA SOUTH DOOR IS SHOWN.
PEDESTRIAN CONNECTIVITY: NEW PEDESTRIAN CROSSWALK AND "PEDESTRIAN TRAFFIC" CAUTION SIGNS SHOWN. ALSO,
NEW CONCRETE SIDEWALK IN THE PLAYGROUND AND ACCESSIBLE ASSESS TO THE
FUTURE RETAIL EXISTING TREE PLAYGROUND IS SHOWN.
SITE LIGHTING: FIVE EXISTING WALL PACKS ON THE EAST SIDE OF THE BUILDING ARE SHOWN. TWO NEW POLE
MOUNTED LED DOWN-LIGHTS ARE SHOWN TO ILLUMINATE THE PARKING LOT.
PAINT: ALL STRIPING SHALL BE 4" WIDE. ONLY VIVID AND DURABLE PAINT SHALL BE USED AND SHALL
BE SUITABLE FOR STREET SURFACES. TYPICAL STRIPING SHALL BE WHITE. ACCESSIBLE
SPACES, AISLES, AND INTERNATIONAL SYMBOL OF ACCESSIBILITY SHALL BE BLUE. YELLOW
PAINT USED FOR FIRE LANES SHALL BE THE ACCEPTED YELLOW AS UTILIZED BY DELDOT.
EMERGENCY SERVICES
PERIMETER ACCESS: PER CITY FIRE MARSHAL, PERIMETER ACCESS SHALL BE 50% AND BE CLEARLY MARKED ON
THE PLANS. PER DSFPR 705.4.5, MINIMUM WIDTH OF PERIMETER ACCESS SHALL BE 15' FROM
FACE OF BUILDING, AT GRADE, WITH A MAXIMUM SLOPE OF 10%. PARKING SHALL NOT BE
LOCATED CLOSER THAN 15' FROM THE FACE OF THE BUILDING.
8'-0" ACTUAL: PERIMETER ACCESS IS 783' OF THE PERIMETER, FOR 89%, AS SHOWN ON THE PLANS
EXISTING USING DASHED LINE. PARKING IS MINIMUM 15' (8' FOR 7 SPACES) FROM FACE OF BUILDING.
25'-3"
MEDICAL
OFFICE 7 DESIGN OF FIRE LANES: PER CITY FIRE MARSHAL, FIRE LANES SHALL COVER 25% OF THE BUILDING. PER DSFPR
705.6.2, WIDTH OF FIRE LANES SHALL BE MINIMUM 24' WIDE. PER 705.6.4 AND 705.6.5, THE
5 SO TH LITTLE CREEK ROAD
F
PROPOSED CLOSEST EDGE OF FIRE LANES SHALL BE MINIMUM 10' AND NO FURTHER THAN 50' FROM THE
PARKING EXTERIOR WALL OF THE BUILDING. PER 705.6.4.1, WHERE PARKING IS LOCATED BETWEEN
BUILDING AND FIRE LANE, PARKING SHALL BE MINIMUM 15' FROM THE EXTERIOR WALL OF THE
CONDITIONAL SE SITE PLAN FOR
BUILDING.
31'-8"
ACTUAL: FIRE LANES ARE EXISTING AND COVER 407' OF THE PERIMETER, FOR 49%. THE
13 CLOSEST EDGE OF THE FIRE LANES FROM THE EXTERIOR WALL OF THE BUILDING VARIES, AS
DIMENSIONED (5'-6", 11'-0", 31'-8", AND 25'-3" )
EXISTING
JJ S LEARNING
PARKING MARKING OF FIRE LANES: PER DSFPR 705.7, BOTH INNER AND OUTER EDGES OF THE FIRE LANE SHALL BE MARLED WITH 4"
WIDE SOLID YELLOW DEMARCATION LINE. FIRE LANE SIGNS SHALL BE LOCATED MAXIMUM 150'
APART AND PLACED AT THE BEGINNING AND END OF THE FIRE LANE, FACING ONCOMING TRAFFIC, AT
6' TO 8' ABOVE THE PAVEMENT. WHERE PARKING IS RESTRICTED, "NO PARKING" SHALL BE PAINTED
PP IN THE SPACE WITH WORDS MINIMUM 6' HIGH AND 12' IN LENGTH. WHERE PARKING IS NOT
4 RESTRICTED, ROADWAY MARKINGS SHALL USE THE WORDS "FIRE" AND "LANE," IN LIEU OF SIGNS,
MINIMUM10' HIGH, SPACED NO MORE THAN 30' APART, REPEATED AT 100' INTERVALS. 01
ACTUAL: DEMARCATION LINES AND "FIRE" "LANE" MARKINGS ARE EXISTING. NEW LOCATIONS
BABB DRIVE EXISTING FOR FIRE LANE SIGNS ARE SHOWN ON THE PLANS.
E PERIENCE 2 DOVER DELAWARE 1
PARKING
EXISTING 22
OUTDOOR PLAY AREA: REQUIRED OUTDOOR PLAYGROUND AREA = 75 S.F. x (.25 x NO. OF CHILDREN)
PARKING
75 S.F. x (.25 x 170) = 75 S.F. x 43 = 3,224 S.F. REQUIRED
7 EXISTING
S ITE I
ACTUAL = 3,284± S.F. PROPOSED FENCED IN OUTDOOR PLAY AREA
PARKING J.H. BROWN BOULEVARD
TREES: 10,111 S.F. ÷ 3,000 S.F. PER TREE = 4 TREES REQUIRED
ACTUAL: 3 TREES EXISTING + 1 PROPOSED TREE = 4 TREES
TRASH COLLECTION: PROPOSED LOCATION OF NEW SCREENED DUMPSTER IS SHOWN. TRASH COLLECTION SHALL BE
CONTRACTED BY OWNER. NO TRASH WILL ACCUMULATE ON THE SITE.
CONDITIONAL
OWNER CERTIFICATION: I, MOHAMMAD CHAUDRY, HEREBY CERTIFY THAT I AM THE OWNER AND LESSOR OF JJ'S
LEARNING EXPERIENCE 2 SHOWN ON THIS PLAN, AND THAT THE PLAN WAS MADE AT MY SE SITE PLAN
DIRECTION, AND THAT I ACKNOWLEDGE THE SAME TO BE MY ACT AND DESIRE THE PLAN BE
DEVELOPED AS SHOWN IN ACCORDANCE WITH ALL APPLICABLE LAWS AND REGULATIONS AND DATA
COL MN
DATE: SIGNATURE: (OWNER/LESSOR)
DATE: SIGNATURE: (LESSEE)
SHAWANDA JOHNSON
1 DRAWN
MAS
DRAWING LIST: CHECKED
D
W.B.
A
RO C1 CONDITIONAL USE SITE PLAN AND DATA COLUMN DATE
AY
UT
HB 3 FEBR ARY 2021
1 SO C2 CONDITIONAL USE ENLARGED SITE PLAN AND DETAILS SCALE
N
CONDITIONAL USE SITE PLAN NOTED
JOB NO.
AND PARKING LAYOUT PROJECT C1 3 -1120
1" = 30' NORTH SHEET
C1
PROJECT SITE
LOCATION MAP
1" = 200'±
OF SHEETS
50
Page 51
Item 5.
REVISIONS BY
4" SOLID MASONRY
1 3-25-2021 MAS
CAP DOVER PLANNING
COMMISSION COMMENTS
" TE
'-8 RE
10 NC
CO R
T ING O TE 3
IS FO
EX OT T E
CA
P C2 8" CMU PAINTED BOTH
OF L R E
4 " SIDES WITH DARK
GE ING ON
C
TH GRAY EXTERIOR
ED ARK " C W I UM ACRYLIC LATEX PAINT,
P 0 L I N IM UM
LED DOWN-LIGHT ON POLE, 2 L M IM COLOR TO MATCH THE
REFER 10/C2 2 EXISTING "x WA 4" MIN AL
12 U 2 B '- EXISTING EXTERIOR
TREES CM E T " Ø PIC LA
13
8 " S 12 TY S 4" DARK GRAY FINISH
"STAFF PARKING" E
I PE E IN ER, ET SYSTEM ON THE
SIGNS, REFER 8/C2 P D T R
L A O
EE GR FO NC H WEST AND PARTIAL
T CO ":12" L US NORTH ELEVATIONS;
"ADA PARKING" S W T E D 4 F
10 "STAFF PARKING" 6" ELO RE R CE N 1/ BE E APPLIED DIRECTLY TO
SIGN, REFER B ON C O W L
L T E 90°
7/C2 SIGNS, REFER 8/C2 C E INF DO S HA CRE AT
CMU
EXISTING PARKING R E D E ON G
E
12'-0" 4" LOP R ET G C U BL ING
4" WIDE BLUE ADA SYMBOL, S NC TIN DO XIS
T 7'-4"
PARKING, AND WALKWAY NEW PARKING N CO XIS LOT K E
BUMPERS, TYPICAL W E LIN E
STRIPING
5'-0" NE ITH KING A IN E TH
FOR 10 W AR CH BOV T 4" REINFORCED
"FIRE LANE" SIGNS PROJECT P H A O
FACE BOTH DIRECTIONS, ' HIG 6" G L CONCRETE SLAB,
" NORTH 6 ET KIN I PE SLOPED AS SHOWN
'-0
REFER 6/C2 R3
S AR
STR TE (EDGE AT OPENING
6 P
NE RE
LA NC SHALL BE FLUSH WITH
E CO EXISTING CONCRETE
PROPOSED SCREENED FIR TIN
G
PARKING LOT)
G IS
DUMPSTER AND
S TIN EX OT
CONCRETE PAD E XI F
O L
6'-0" 1'-0" G E ING EXPANSION JOINT
TYP. R3 ED ARK
6'- P
EXISTING FIRE LANE 12'-0" LED DOWN-LIGHT ON
0"
MARKINGS POLE, REFER 10/C2 1/4":12" SLOPE EXISTING GRADE
2'-0"
NEW "FIRE LANE" SIGN,
2 DUMPSTER ENCLOSURE PLAN
TYP.
24'-0"
REFER 6/C2 EXISTING WALL PACK
NEW STEPS
4" WIDE DOTTED
NEW PEDESTRIAN 2 SKIPS, PAINTED COMPACTED FILL
CROSSWALK STRIPING, 1'-0" 2'-0" DROP OFF AREA 5-BIKE RACK, REFER 4/C2 1/4" = 1'-0"
WHITE, TYPICAL
12'-0"
2'-0" MINIMUM
WHITE PAINT, TYPICAL C1 TYP. TYP.
11'-0"
"DROP OFF AREA" SIGN,
24'-4" 32'-5"
REFER 9/C2
NEW ENTRANCE- EXISTING WALL
5'-6" 5'-0" EXIT PACK
CONCRETE FOOTER
WITH TWO #4 BARS, 1'-0"
EXISTING WALL CONTINUOUS
NEW PACK EXISTING WALL PACKS
PEDESTRIAN M
ENTRANCE/EXIT FOR
CROSSWALK MU
STRIPING, SCHOOL AGED CHILDREN INI 1'-8"
"M
'-0
3
WHITE PAINT 25
NEW RAILING
3,284± S.F. 44'-5" WALL SECTION
SUITE I RAMP, WHICH IS PART OF PROPOSED
PROPOSED
DAY CARE
ACCESSIBLE PATH TO
PLAYGROUND
DAYCARE PLAYGROUND @ DUMPSTER ENCLOSURE
7 10,111± S.F. 3/4" = 1'-0"
0"
2'- P.
0 " TY PROPOSED PARKING
6'-
" 1'-0 P.
T Y
PP PROPOSED TREE
NEW "PEDESTRIAN
TRAFFIC" SIGNS NEW 5' WIDE CONCRETE SIDEWALK
REFER 5/C2 NEW PARKING BUMPERS,
TYPICAL FOR 7
20'-6"
NEW 6' HIGH CHAIN LINK FENCE
EXISTING PARKING PROPOSED NEW EGRESS
"STAFF PARKING" SIGNS, CORRIDOR
TYPICAL FOR 7, MOUNTED
TO WALL, REFER 8/C2 DIRECT PATH TO
5 SO TH LITTLE CREEK ROAD
PLAYGROUND
3 62'-4"
CONDITIONAL SE SITE PLAN FOR
FH
EXISTING CURB
31'-8"
4 PROPOSED 5-BIKE RACK 250 WATT LED DOWN-LIGHT
FIXTURE ATTACHED TO LIGHT POLE
JJ S LEARNING
N.T.S. -- GLOBAL INDUSTRIES ITEM #T9F652770 OR EQUIVALENT 16'± LIGHT POLE
1 CONDITIONAL USE N
BOLT PLATE COVER 10 1/2" x 10 1/2" x 4"
3/4" x 30" ANCHOR BOLTS, TYPICAL
ENLARGED SITE PLAN PROJECT BOLT PLATE 10 1/2" x 10 1/2" X 3/8" 01
1/16" = 1'-0" NORTH
NON-SHRINK GROUT AFTER
DOVER DELAWARE 1
MOUNTING AND LEVELING POLE
E PERIENCE 2
SLOPE CONCRETE FOR DRAINAGE
3"
S ITE I
WHITE LETTERS RED LETTERS BLUE LETTERS
SYMBOLS & SYMBOLS & SYMBOLS & BLACK LETTERS BLACK LETTERS 1'-6"
1'-0"
BORDER BORDER BORDER & BORDER & BORDER GRADE
RESERVED
DAYCARE NO
YELLOW WHITE BACKGROUND BACKGROUND BACKGROUND PARKING
BACKGROUND 2'-0" BACKGROUND WHITE WHITE
STAFF CONDITIONAL
1'-6"
________
PARKING WHITE DROP-OFF
ONLY
AREA SE ENLARGED
EXISTING SITE PLAN AND
2" RND. GALV. 2" RND. GALV. 2" RND. GALV. 2" RND. GALV.
6'-0" MINIMUM 6'-0" MINIMUM
RAMP AND
STEEL PIPE STEEL PIPE STEEL PIPE STEEL PIPE RAILING PVC CONDUIT DETAILS
EXISTING EXISTING EXISTING EXISTING
5'-0" MINIMUM
PAVING PAVING PAVING PAVING
3,000 PSI CONCRETE BASE CAST AGAINST
UNDISTURBED EARTH
1'-9" 1'-9"
CONCRETE CONCRETE CONCRETE CONCRETE APPROXIMATE #3 REBAR WITH #3 REBAR TIES @ 12" O.C.
DRAWN
MAS
GRADE CHECKED
W.B.
8" 8"
DATE
3 FEBR ARY 2021
NOTE: STAFF PARKING SIGNS AT BUILDING DO NOT NEED SCALE
PIPE AND SHALL BE ATTACHED TO THE CMU WALL 3" NOTED
JOB NO.
C1 3 -1120
5 PEDESTRIAN TRAFFIC 6 "FIRE LANE" 7 ADA PARKING 8 STAFF PARKING 9 DROP OFF AREA
10 LIGHT POLE AND
SHEET
1
SIGN ELEVATION
1/2" = 1'-0"
SIGN ELEVATION
1/2" = 1'-0"
SIGN ELEVATION
1/2" = 1'-0"
SIGN ELEVATION
1/2" = 1'-0"
SIGN ELEVATION
1/2" = 1'-0" BASE DETAIL
3/4" = 1'-0"
3"
1'-6"
3"
C2 OF SHEETS
51
Page 52
Item 5.
REVISIONS BY
CONDITIONAL USE SITE PLAN DATA COLUMN:
DAYCARE NAME: JJ'S LEARNING EXPERIENCE 2
ADDRESS: SUITE I, 756 SOUTH LITTLE CREEK ROAD
DOVER, DELAWARE 19901
HOURS & DAYS OF OPERATION: MONDAY -- FRIDAY 5:45 AM TO 7:00 PM
SATURDAY 7:00 AM TO 12:00 PM
SUNDAY CLOSED
2 EXISTING OWNER'S NAME
TREES AND ADDRESS: EMPIRE MEDICAL, LLC
1100 LA GRANGE PARKWAY, NEWARK, DE 19702
PROPOSED REPRESENTED BY MOHAMMED CHAUDRY
SCREENED
DUMPSTER & TAX MAP NUMBER: ED-05-O77.00-01-030.000-000
CONCRETE
10 PAD LOT AREA: 2.39 ACRES
EXISTING
PARKING ZONING: C4
ENTRANCE/EXIT OCCUPANCY TYPE: PROPOSED GROUP I-2 DAYCARE
FOR SCHOOL
NEW STEPS AGED BUILDING AREA: 33,143 S.F., EXISTING
CHILDREN
NEW ENTRANCE/EXIT NEW RAILING DAYCARE AREA: 10,111 S.F. PROPOSED DAYCARE
NEW RAMP
UP NUMBER OF CHILDREN: 170 CHILDREN
UP
F F
NUMBER OF ADULTS: 19 ADULTS
3,280± S.F.
PROPOSED REQUIRED PARKING: 170 CHILDREN ÷ 10 CHILDREN PER SPACE = 17 PARKING SPACES
S S S S
DAYCARE 19 ADULTS ÷ 1 ADULT PER SPACE = 19 PARKING SPACES
PLAYGROUND TOTAL REQUIRED = 36 PARKING SPACES
7 SUITE I
EXISTING PROPOSED ACTUAL PARKING: EXISTING PLUS PROPOSED: 73 SPACES, INCLUDING 3 ACCESSIBLE SPACES
PP PARKING PROPOSED
PARKING DAY CARE
10,111± S.F. OUTDOOR PLAY AREA: REQUIRED OUTDOOR PLAYGROUND AREA = 75 S.F. x (.25 x NO. OF CHILDREN)
3 PROPOSED 75 S.F. x (.25 x 170) = 75 S.F. x 43 = 3,224 S.F. REQUIRED
TREE ACTUAL = 3,280± S.F. PROPOSED FENCED IN OUTDOOR PLAY AREA
S S S S TREES: 10,111 S.F. ÷ 3,000 S.F. PER TREE = 4 TREES REQUIRED
ACTUAL: 3 TREES EXISTING + 1 PROPOSED TREE = 4 TREES
FH TRASH COLLECTION: PROPOSED LOCATION OF NEW SCREENED DUMPSTER IS SHOWN. TRASH COLLECTION SHALL BE
CONTRACTED BY OWNER. NO TRASH WILL ACCUMULATE ON THE SITE.
SOUTH LITTLE CREEK ROAD
OWNER CERTIFICATION: I, MOHAMMAD CHAUDRY, HEREBY CERTIFY THAT I AM THE OWNER AND LESSOR OF JJ'S
LEARNING EXPERIENCE 2 SHOWN ON THIS PLAN, AND THAT THE PLAN WAS MADE AT MY
DIRECTION, AND THAT I ACKNOWLEDGE THE SAME TO BE MY ACT AND DESIRE THE PLAN BE
S
DEVELOPED AS SHOWN IN ACCORDANCE WITH ALL APPLICABLE LAWS AND REGULATIONS
FUTURE RETAIL EXISTING TREE
DATE: SIGNATURE: (OWNER/LESSOR)
F
DATE: SIGNATURE: (LESSEE)
SHAWANDA JOHNSON
S
F
F S
F
F
F
F S
F
EXISTING
SO TH LITTLE CREEK ROAD
MEDICAL
F
OFFICE S
6
CONDITIONAL SE SITE PLAN FOR
F
PROPOSED
PARKING
JJ S LEARNING
13
EXISTING
PARKING
PP
J.H. BROWN BOULEVARD
4
E PERIENCE DOVER DELAWARE
BABB DRIVE EXISTING
PARKING
S ITE I
EXISTING 23
PARKING
7 EXISTING
PARKING
CONDITIONAL
SE SITE PLAN
AND DATA
COL N
AD
RO
Y
H BA
UT DRAWN
SO AS
CHECKED
W.B.
DATE
FEBR ARY
PROJECT SITE SCALE
NOTED
N JOB NO.
CONDITIONAL USE C
SHEET
SITE PLAN AND PARKING LAYOUT PROJECT LOCATION MAP
C
NORTH
1" = 30' 1" = 200'±
OF SHEETS
52
Page 53
Item 6.
PETITION TO AMEND ZONING DISTRICT
Public Hearing Before the Planning Commission
April 19, 2021
Owner: Silver Linings Holdings Corp. c/o Tolano Anderson
Address: 630 W. Division Street, Dover DE
Location: South side of W. Division Street opposite Ridgely Street
Tax Parcel: ED-05-076.08-01-40.01-000
Size: 1.08 acres (47,275.3 SF.)
Present Use: Professional Office
Proposed Use: Office and Residential
Comprehensive
Plan Designation: Mixed-Use
Present Zoning: C-3 (Service Commercial Zone) and COZ-1 (Corridor Overlay
Zone)
Proposed Zoning: C-2A (Limited Central Commercial Zone) and COZ-1 (Corridor
Overlay Zone)
Reason for Request: To amend the zoning of the 1.08+/- acre parcel at 630 W. Division
Street, Dover DE 19904 from C-3 to C-2A.
To partially convert the existing office building to include
Apartment Units.
File Number: Z-21-03
Ordinance Number: 2021-07
53
Page 54
Item 6.
Z-21-03 Lands of Silver Linings Holding Corporation at 630 W Division St
DAC Report of April 7, 2021
Page 2
This rezoning application consists of one parcel of land totaling 1.08 +/- acres located on the
south side of W. Division Street opposite the intersection with Ridgely Street. The property is
zoned C-3 (Service Commercial Zone) subject to the COZ-1 (Corridor Overlay Zone). The
proposed zoning is C-2A (Limited Central Commercial Zone) while remaining subject to the
COZ-1 (Corridor Overlay Zone). The owner of record is Silver Linings Holding Corporation c/o
Tolano Anderson. Property Address: 630 W. Division Street. Tax Parcel: ED-05-076.08-01-
40.01-000.
Existing Property:
The property has frontage along West Division Street to the north and contains a professional
office building. Vehicle access to the site is via a shared access with the neighboring property to
the east (650 West Division Street) off of West Division Street. While there is a sidewalk along the
West Division Street frontage, there is no dedicated pedestrian access from this sidewalk into the
site. Almost the entire property is either paved or covered by the existing building. The applicant is
seeking rezoning to C-2A (Limited Central Commercial Zone) to allow for Apartments to be
established in addition to the existing Professional Office Use. The COZ-1 (Corridor Overlay
Zone) will remain. Any change of use of the site will be subject to permit submissions. This
application only seeks rezoning of the property from C-3 to C-2A; the COZ-1 (Corridor Overlay
Zone) designation will remain.
Previous Application:
This property was recently subject to Rezoning Application Z-20-03 Lands of Telano D.
Anderson at 630 West Division Street, which sought to rezone the property from the existing C-3
(Service Commercial Zone) to IO (Institutional and Office Zone) while retaining the COZ-1
(Corridor Overlay Zone) designation. This rezoning was sought to allow for the establishment of
an Emergency Shelter which is a permitted use in the IO zoning district.
The Z-20-03 Rezoning Application received a Recommendation of Approval from the Planning
Commission at their November 2020 meeting. However, the Application was ultimately denied
by the City Council at their December 14, 2020 meeting and the Rezoning of the property to IO
was consequently not permitted.
Surrounding Land Uses
The surrounding parcels are all zoned commercial. The property immediately adjacent on the
east and south of the property is zoned C-3 and contains a mini-storage facility. Immediately
adjacent to the west is another property zoned C-3 which contains a car wash facility. Across
West Division Street to the north are properties again zoned C-3 and also C-2A (Limited Central
Commercial Zone), containing a variety of commercial uses. The subject property, as well as the
surrounding parcels have a Land Use Category of Mixed Use. This is with the exception of the
parcels to north and east of the subject property (across West Division Street but immediately
east of Ridgley Street) which have a Land Use Category of Industrial.
Comprehensive Plan:
In the 2019 Comprehensive Plan, the Land Development Plan (Map 12-1) recommends that this
property be used for Mixed Use. The 2019 Comprehensive Plan references Mixed Use land use
category on page 12-7. The following is an excerpt from the 2019 Comprehensive Plan
regarding Mixed Use land uses (page 12-8):
54
Page 55
Item 6.
Z-21-03 Lands of Silver Linings Holdings LLC
DAC Report of April 7, 2021
Page 3
Recommendation for Downtown Dover – Historic Core and Center City: Mixed Use Area:
Downtown Dover is the City’s primary Mixed Use area. The historic City center clustered around
The Green dates back as early as the 1700s. It expands to also include the traditional City pattern
of grid streets which developed during the 19th and early 20th centuries. As a result of its earlier
development, Downtown Dover, like many other historic cities, includes a variety of intermingled
land uses. The Downtown area, which includes the traditional Loockerman Street business
district, is broadly bounded by Wesley College on the north, the railroad tracks on the west,
Bayhealth-Kent General Hospital on the south, and St. Jones River on the east. It includes a
street level mix of residential, commercial, office, cultural, and institutional uses.
Downtown Dover is the traditional and symbolic center of the community and is vitally important
to the overall image and identity of the City. As the State’s office complex and other businesses
and services make Downtown the largest area of employment in the City, Downtown Dover is
vital to the economy. It is important to preserve the area as a safe, convenient, and aesthetically
pleasing business environment. Downtown provides a unique and affordable commercial
environment where locally owned businesses reflect the small-town nature of the community.
Downtown also provides a residential environment with a wide variety of housing types near
commercial, cultural, education, and employment resources. The age of the buildings and
infrastructure in the Downtown area requires special attention and incentives to assist in continual
use and revitalization activities. Downtown lacks the vibrancy of years gone by and its
revitalization will hinge on mixed land uses and developing a commercial niche. Removal of
blighted conditions, rehabilitation and redevelopment of traditional residential areas, and
reestablishment of neighborhood identity will be important components of the City’s strategies
and initiatives.
The goal of the Land Development Plan is to enhance the role of Downtown Dover as a major
employment, residential and commercial center as well as the symbolic and cultural heart of the
community. Efforts should strive to recognize its unique heritage and historic resources and to
provide for mixed use development allowing greatest variation of uses, Activities to reestablish
the economic and social vitality of Downtown neighborhoods are encouraged.
The Rezoning Request is consistent with the Land Use Classification of Mixed Use. Table 12-1:
Land Use and Zoning Matrix (from the 2019 Comprehensive Plan) specifies that the following
zones are compatible with this land use classification.
C-2 (Central Commercial) (Downtown Redevelopment Target Area Only)
C-2A (Limited Central Commercial)
TND (Traditional Neighborhood Design)
C-1 (Neighborhood Commercial)
C-1A (Limited Commercial)
RGO (General Residence and Office) (Downtown Redevelopment Target Area
Only)
Mixed-Use R-8 (One Family Residence)
R-10 (One Family Residence)
RG-1 (General Residence)
RG-2 (General Residence)
RG-4 (General Resident - Multi-Story Apartments)
C-3 (Service Commercial)
CPO (Commercial and Professional Office)
IO (Institutional and Office)
55
Page 56
Item 6.
Z-21-03 Lands of Silver Linings Holdings LLC
DAC Report of April 7, 2021
Page 4
Request for C-2A (Limited Central Commercial Zone) Zoning
• The following description of the C-2A zoning district is provided from Article 3 §14 of
the Zoning Ordinance.
Article 3 Section 14. – Limited Central Commercial Zone (C-2A).
14.1 Uses permitted. No building or premises shall be used and no building or part of a building shall
be erected, which is arranged, intended or designed to be used, in whole or in part, for any purpose,
except the following:
(a) Retail Stores
(b) Business, professional or government offices
(c) Personal service establishments.
(d) Restaurants.
(e) Service establishments.
(f) Hotels.
(g) Places of public assembly.
(h) Drive-throughs.
(i) One family residences, including attached and semi-detached dwellings, complying with
the bulk standards of the RG-1 (General Residence) zone.
(j) Apartments and multi-family dwellings
14.2 Conditional Uses. The following uses are permitted, conditional upon the approval of the
planning commission in accordance with the procedures and subject to the general conditions set
forth in article 10, section 1:
(a) Parking lots and parking structures as a principal use on suitably landscaped lots.
(b) Fuel pumps accessory to a permitted use.
14.3 Enclosed buildings. All permitted uses and all storage accessory thereto, other than off
street parking, shall be carried on in buildings fully enclosed on all sides, except for outdoor
eating areas associated with restaurants and outdoor sales areas approved by the city planner.
14.4 Performance standards. All uses are subject to performance standards as set forth in article
5, section 8.1.
14.5 Site development plan approval. Site development plan approval in accordance with article
10, section 2 hereof shall be required prior to the issuance of building permits for the erection or
enlargement of all structures and prior to the issuance of certificates of occupancy for any change
of use.
COZ-1 (Corridor Overlay Zone)
The purpose and requirements of the COZ-1 (Corridor Overlay Zone) are given in Article 3 §27
of the Zoning Ordinance. The COZ-1 regulations include the following:
27.1 Purpose. The corridor overlay zone (COZ) is established for the following reasons:
(a) To promote superior urban corridor development and the highest quality built
environment;
56
Page 57
Item 6.
Z-21-03 Lands of Silver Linings Holdings LLC
DAC Report of April 7, 2021
Page 5
(b) To foster coordination and linkage among corridor properties and with adjacent lands;
(c) To preserve the functionality and efficiency of the roadway for traffic movement; and
(d) To achieve a visually balanced streetscape environment which is friendly to the
pedestrian and motorist alike.
27.2 Superior urban design. For the purposes of this ordinance the term "superior urban design"
shall meet the following criteria:
(a) Superior urban design places a strict and primary importance on the pedestrian. The
concept should lend itself to interconnectivity while presenting building structures as
aspects of the street, not simply islands existing in the "sea of roads". The design should
encourage fewer car-trips, as well as promote automobile trips on an interconnected local
street system rather than trips that utilize the arterials. In demonstrating superior urban
design, an applicant must show that the plan presented exceeds the requirements of the
zoning ordinance in at least two of the following areas:
(i) Transportation amenities for bicycles, pedestrians and transit that exceed
those required by the zoning ordinance;
(ii) Architectural features including, but not limited to: LEED-certified buildings;
unique architecture not replicated in other locations; use of architectural elements
such as entry porticos, porte-cocheres, colonnades, cornices, porch columns and
balusters, band courses, coins, water tables and other trim that enhances visual
quality and function of the structure; and use of the highest-quality construction
materials.
(iii) Landscaping that exceeds the requirements of this section, including robust
use of trees, shrubbery, and flowering plants to screen parked cars; water
gardens and ponds; arboretums; tree preservation measures;
(iv) Public spaces and art including, but not limited to, sculpture, memorials,
murals, public court yards and pocket parks, and fountains;
(v) Green technologies for stormwater management, as well as green energy
technologies such as geothermal heating and cooling and solar energy supplies.
(b) The city planner shall develop policy guidance on how the concept of superior
urban design will be evaluated.
27.3 Zone boundaries. The COZ encompasses the lands adjacent to the following roadways as
outlined on the City of Dover Zoning Map as set forth in article 2, section 2 of this ordinance:
(a) Delaware Route 8 (Forrest and Division Streets) from the railroad tracks in a westerly
direction to the city limit line.
(b) McKee/Saulsbury Road (County Road 156) from the intersection at Dennys Road
(County Road 100) in a southerly direction to the terminal intersection with West North
Street (County Road 73).
27.4 Permitted uses. Land use shall be governed by those provisions of this ordinance related to
the specific zoning district designations of each property as depicted on the zoning map.
57
Page 58
Item 6.
Z-21-03 Lands of Silver Linings Holdings LLC
DAC Report of April 7, 2021
Page 6
27.5 Site development plan approval. Site development plan approval in accordance with article
10, section 2 shall be required prior to the issuance of building permits for the erection or
enlargement of all structures and prior to the issuance of certificates of occupancy for any change
in use. When the zoning district regulations specify that a particular use requires conditional use
approval in accordance with article 10, section 1, the provisions of that article shall apply. Site
development plans and conditional use site plans for properties within the COZ shall reflect
compliance with the development guidelines of this article, in addition to all other applicable
codes and regulations.
27.6 Development guidelines.
27.61 Setbacks:
a. Front yards.
Residential Nonresidential
Min. Max. Min. Max.
McKee/Saulsbury 60' to 80' 40' to 50' *
Route 8—Artis Drive to Mifflin Road 60' to 80' None
Route 8—Mifflin Road to Saulsbury
40' to 60' 40' to 60' *
Road
Route 8—Saulsbury Road to R.R. line 20' to 30' 20' to 30'
Subdivision streets (Setback provisions of article 4 shall apply)
* When the applicant can demonstrate to the satisfaction of the planning commission through the site plan
review process that the proposal involves a superior urban design, the maximum setback may be
increased to no more than 90 feet from the property line on Route 8 from Mifflin Road to Saulsbury Road
and on McKee and Saulsbury Roads.
27.62 Building placement. Buildings shall be situated on the property so as to maximize the use
of the frontage along the roadway and shall have the longest side of the building arranged parallel
and square to the roadway. When the applicant can demonstrate to the satisfaction of the
planning commission that, due to specific constraints related to lot configuration, alternative
building placements may be permitted.
27.63 Parking.
(a) Location. Parking shall not be permitted to be situated within the front yard, nor
between the right-of-way line and the building, except in the following instances:
(i) Automobile service stations;
(ii) Properties in a shopping center (SC) zoning district, in which case, parking
may be permitted between the building and the roadway, provided that such
parking [shall] be limited to five rows of single parking spaces between the road
and the storefront;
(iii) When the applicant can demonstrate to the satisfaction of the planning
commission through the site plan review process that the design presented
involves a superior urban design, parking may be permitted between the building
58
Page 59
Item 6.
Z-21-03 Lands of Silver Linings Holdings LLC
DAC Report of April 7, 2021
Page 7
and the street, provided that such parking within this area shall be adequately
landscaped and screened from the roadway.
(b) Required number of spaces. See specific district requirements in article 4.
(c) Layout.
(i) Parking lots shall be arranged in such a manner so that not more than 20
parking spaces in a row shall be permitted without a landscaped island. No more
than six rows of 20 spaces shall be provided without provision for a landscaped
median. Parking islands shall be a minimum of ten feet wide and planting
medians shall be no less than eight feet wide.
(ii) There shall be a landscaped buffer area of at least 12 feet in width between
the building and parking lot and drive areas. The buffer area shall include
provisions for a sidewalk of at least six feet and no greater than eight feet in
width. The buffer area and sidewalk shall be grade separated from the parking lot
by concrete curbing of at least six inches in height.
(d) Landscaping. Design shall be simple and easy to maintain and shall consist of a
combination of hardy canopy trees, low evergreen shrubs and turf grass, and shall be
designed in accordance with landscape guidelines set forth in article 5, section 15 of this
ordinance and as follows:
(i) Interior landscaping. A minimum of five percent of the interior area of a parking
lot shall be reserved for landscape purposes. This provision shall include the
landscaping of all required parking islands and medians. Shade trees shall be
incorporated within the landscaped islands whenever and wherever practicable.
(ii) Parking lot screening adjacent to public right-of-way. Low profile screening
shall be required when parking spaces would result in vehicles facing onto the
roadway. Screening may consist of a low wall, evergreen hedge with a minimum
height of two feet at the time of planting, planted three feet apart on center, and a
maximum height of three feet at maturity, or earth berm. Should a low wall be
used, such wall shall be accompanied by evergreen shrub plantings on the
roadway side of the wall and spaced ten feet apart on center.
(iii) Reserved.
27.64 Site access.
(a) Entrance width and radii. Site entrances shall have a minimum width of 24 feet.
Entrances involving a median divider shall be at least 35 feet in width. Entrance radii shall
be a minimum of 15 feet and a maximum of 25 feet.
(b) Number of entrances and curb cut spacing. One curb cut shall be permitted for each
street which abuts a site. For sites with street frontage in excess of 300 linear feet, one
additional curb cut may be permitted. For sites with street frontage in excess of 600 linear
feet, two additional curb cuts may be permitted.
Multiple curb cuts on a property shall have a minimum spacing distance in accordance
with the following schedule:
59
Page 60
Item 6.
Z-21-03 Lands of Silver Linings Holdings LLC
DAC Report of April 7, 2021
Page 8
Speed Limit Maximum Spacing (Ft.)
25 105
30 125
35 150
40 185
45 230
50 275
(c) [Shared access.] Shared access shall be provided, whenever possible, for entrances
to adjoining uses, including residential driveways.
(d) [Cross access.] Cross access shall be provided among abutting uses of similar use
categories, whenever possible, to provide linkage between properties as an alternative to
re-entering the corridor to access both existing and future neighboring properties.
(e) Entrance locations for adjoining properties. Commercial site entrances shall be no
closer than 25 feet to an adjoining property which is zoned residential and no closer than
ten feet to an adjoining property which is in a nonresidential zoning category.
27.65 [Signs.] Signs shall meet the regulations found in article 5, section 4, supplementary sign
regulations.
27.66 Building height.
(a) Buildings shall be limited in overall height to 35 feet and shall not exceed two stories.
27.67 Open space and landscaping.
(a) Lot coverage. Each lot shall have a minimum of 25 percent of the lot area dedicated
to be landscaped open space. A lesser amount of landscaped open space may be
permitted when it can be demonstrated to the satisfaction of the planning commission,
through the site plan review process, that, due to lot configuration and existing built
conditions, the required minimum is impractical.
(b) Frontage. Each lot shall have a landscaped open space of at least 25 feet in width,
measured from the back of curb along the entire frontage of the lot, except at points of
site access. Trees shall be provided along the frontage perimeter at a minimum rate of
one tree for each 50 linear feet of frontage.
(c) Side and rear yards. A minimum of 15 feet of landscaped open space shall be
provided along all side and rear lot lines when abutting a residential use and a minimum
of five feet when abutting a nonresidential use. Tree plantings shall be provided along all
nonfrontage perimeters at a minimum rate of one tree for each 75 linear feet.
(d) Stormwater detention ponds. Detention ponds may be counted toward the minimum
25 percent open space area, provided that such ponds are designed to emulate natural
features by incorporating irregular outline, gradual slopes (no greater than 1:4), and
appropriate landscape plantings.
60
Page 61
Item 6.
Z-21-03 Lands of Silver Linings Holdings LLC
DAC Report of April 7, 2021
Page 9
(e) Landscaping. Landscaped open spaces shall be designed in accordance with the
provisions of this section, as well as the landscaping guidelines as set forth in article 5,
section 9 of this ordinance.
(f) Screening. The following items shall be located so as to minimize visibility from the
roadway, adjacent properties and other public areas, and shall be screened from public
view:
(1) Service bays;
(2) Loading docks and platforms;
(3) Rooftop utilities;
(4) Satellite dishes;
(5) Dumpsters;
(6) Storage areas.
(g) Standard for tree plantings. Trees shall be of a high canopy variety and shall be
limbed to a minimum height of 12 feet above grade at maturity.
(h) Standards for shrubbery. Shrubbery shall be of a low evergreen variety and shall be
limited to use as foundation plantings and for screening purposes.
(i) Standards for ground cover. Ground cover shall be limited to turf and ornamental
grasses and ornamental evergreen ground cover plantings within required landscape
areas.
27.68 Lot configuration. All lots within the corridor overlay district created after the enactment of
this section shall conform to the following:
(a) Minimum lot area [shall be] 10,000 square feet. Service stations [shall have a
minimum lot area of] 20,000 square feet.
(b) Minimum lot depth shall be 100 feet. In the C-3 (service commercial) district, the
minimum lot depth shall be 150 feet.
(c) Minimum road frontage shall be at least 100 feet. In the C-3 (service commercial)
district, the minimum road frontage shall be 150 feet.
27.69 Architectural review. The side of any building which faces the corridor (or corridors) shall
be referred to as the "corridor elevation." Buildings in the COZ-1 shall be designed to front on the
corridor, and the corridor elevation shall contain architectural elements traditionally associated
with the front of a building. Blank walls without functioning windows are prohibited along the
corridor. Windows must be incorporated into the overall design concept of the corridor elevation.
Providing one or several small windows on a large corridor elevation shall not constitute
compliance with this ordinance.
A "functioning window" shall be defined as a window which lets light into the interior of the
structure, and is integrated and related to the interior layout of the space. In addition to
functioning windows, the corridor elevation shall have the following elements:
(a) A primary entrance door or doors (except for loading doors).
(b) A primary entrance feature, such as a porch, portico, awning, entrance walk, or other
similar feature.
61
Page 62
Item 6.
Z-21-03 Lands of Silver Linings Holdings LLC
DAC Report of April 7, 2021
Page 10
In addition, the corridor elevation shall have one of the following elements:
(a) Landscaping integrated into the building design concept.
(b) Architectural or urban design elements which link adjacent structures together, such
as plazas, walkways, colonnades, or similar features.
(c) Architectural relief, such as vertical and horizontal offsets in exterior wall elevations,
band courses, lintels and sill courses, cornices, and the like, to create shadow lines.
The applicant shall submit 12 copies of the corridor elevation at the time of application. The city
planner or his/her designee shall determine whether compliance with the provisions of this
ordinance has been achieved.
27.7 Properties located on a corner lot with two frontages within the Corridor Overlay Zone. When
a property is located on the corner of two corridors within the Corridor Overlay Zone, only one of
the two corridors shall be subject to the requirements of Section 27.61 Setbacks and Section
27.63 Parking, Subsection (a) Location. The frontage of the property on which the identifiable
front of the building is located shall be the frontage that is subject to the requirements of Section
27.61 And Section 27.63, Subsection (a). In designing the site, in order to qualify for the relief
under this subsection, the applicant must demonstrate to the satisfaction of the planning
commission that the design incorporates the principles of superior urban design as defined in
Section 27.2.
Zoning Definitions:
Apartment: A dwelling unit, within a building with other uses and/or dwelling units, that is
intended for use as a residence by an individual or a single family.
Dwelling unit: A building or entirely self-contained portion thereof containing complete
housekeeping facilities for only one family, including any domestic servants employed on
the premises, and having no enclosed space (other than vestibules, entrance or other
hallways or porches) or cooking or sanitary facilities in common with any other dwelling
unit. A boarding[house] or roominghouse, convalescent home, dormitory, fraternity or
sorority house, hotel, inn, lodging, nursing, or other similar home, travel trailer, recreational
vehicle, or other similar structures or vehicles shall not be deemed to constitute a dwelling
unit.
Recommendation of the Planning Staff:
Staff recommends that the Rezoning be granted to C-2A (Limited Central Commercial Zone)
while retaining the COZ-1 (Corridor Overlay Zone) as requested, as the proposed zoning is
consistent with the Comprehensive Plan for the Mixed Use land use classification. The use as a
Professional Office Building with Apartments is permitted in the C-2A Zone. Were the
application for Rezoning to be recommended by the Planning Commission and subsequently
approved by the City Council, the applicant would still have to submit Building Permits for the
change of use in order for the Apartment use of the site to be established. During that review
process it will be determined if any site improvements are required.
This recommendation is being made without that benefit of hearing the comments of surrounding
landowners and residents. A public hearing is required on this matter and the Planning
Commission should give those comments consideration.
62
Page 63
Item 6.
Z-21-03 Lands of Silver Linings Holdings LLC
DAC Report of April 7, 2021
Page 11
ADVISORY COMMENTS TO THE APPLICANT:
1) The applicant shall be aware that approval of any rezoning application does not represent a
Building Permit, Sign Permit or other construction activity permit approval. A separate
application submission is required before issuance of permits by the City of Dover.
2) The applicant shall be aware that any future use of the existing structures may be subject to a
separate permitting or licensing process through the City of Dover Licensing and Permitting
Division. Certain types of uses also require a Public Occupancy Permit.
If you have any questions or need to discuss any of the above comments, please call the
above contact person and the Planning Office as soon as possible.
63
Page 64
Item 6.
CITY OF DOVER
DEVELOPMENT ADVISORY COMMITTEE
APPLICATION REVIEW COMMENTARY
STAFF D.A.C. MEETING DATE: MARCH 31, 2021
APPLICATION: Lands of Silver Linings Holding Corporation at
630 W. Division Street
FILE #: Z-21-03
REVIEWING AGENCY: City of Dover Department of Public Works
CONTACT PERSON: Sharon J. Duca, P.E.
CONTACT PHONE #: 302-736-7025
THE SUBJECT PROPOSAL HAS BEEN REVIEWED FOR CODE COMPLIANCE, PLAN CONFORMITY AND COMPLETENESS IN ACCORDANCE WITH THIS AGENCY’S
AUTHORITY AND AREA OF EXPERTISE. THE FOLLOWING ITEMS HAVE BEEN IDENTIFIED AS ELEMENTS WHICH NEED TO BE ADDRESSED BY THE APPLICANT:
CITY AND STATE CODE REQUIREMENTS:
STORMWATER / STREETS / SANITATION
1. None.
GENERAL
1. Our office has no objection to the rezoning of tax parcels ED-05-076.08-01-40.01-000.
RECOMMENDATIONS SUGGESTED AS CONDITIONS OF APPROVAL TO MEET CODE OBJECTIVES:
STORMWATER / STREETS / SANITATION / GENERAL
1. None.
ADVISORY COMMENTS TO THE APPLICANT:
STORMWATER / STREETS / SANITATION / GENERAL
1. None.
IF YOU HAVE ANY QUESTIONS OR NEED TO DISCUSS ANY OF THE ABOVE COMMENTS, PLEASE CALL THE ABOVE CONTACT PERSON AND THE PLANNING
DEPARTMENT AS SOON AS POSSIBLE.
64
Page 65
Item 6.
CITY OF DOVER
DEVELOPMENT ADVISORY COMMITTEE
APPLICATION REVIEW COMMENTARY
STAFF D.A.C. MEETING DATE: MARCH 26, 2021
APPLICATION: Lands of Silver Linings Holding Corporation at 630 W Division St
FILE #: Z-21-03
REVIEWING AGENCY: City of Dover Department of Water & Wastewater
CONTACT PERSON: Jason A. Lyon, P.E., Director of Water & Wastewater
CONTACT PHONE #: 302-736-7025
CONTACT PHONE #: jlyon@dover.de.us
T HE S UBJECT P ROPOSAL HAS BEEN R EVIEWED FOR C ODE C OMPLIANCE , P LAN C ONFORMITY AND C OMPLETENESS IN
A CCORDANCE WITH THIS A GENCY ’ S A UTHORITY AND A REA OF E XPERTISE .
T HE F OLLOWING I TEMS HAVE BEEN I DENTIFIED AS E LEMENTS W HICH N EED TO BE A DDRESSED BY THE A PPLICANT :
CITY AND STATE CODE REQUIREMENTS
WATER / WASTEWATER
1. Our office has no objection to the rezoning of tax parcels: ED-05-076.08-01-40.01-000.
RECOMMENDATIONS SUGGESTED AS CONDITIONS OF APPROVAL TO MEET CODE OBJECTIVES
WATER / WASTEWATER / GENERAL
1. Should this site be redeveloped, which includes modifications to the use, the applicant / developer will be responsible for all
costs associated with providing the appropriate meter / service / main to this site based upon the use including any necessary
system upgrades or extensions. The appropriateness and adequacy of water and sewer services and meters will be assessed at
that time. (Please note that each water meter registered with the City of Dover must have a separate service line.) Should the
existing water and sanitary sewer services no longer be required based upon the proposed use, they must be properly
abandoned at the mains in accordance with all City of Dover Water / Wastewater Handbook.
2. Any redevelopment shall adhere to the City of Dover Water / Wastewater Handbook.
3. Please note that renovations and or change of use projects must ensure that the water and wastewater service is brought up to
current requirements. This may include relocating the water meter outside or changing service line sizes. Please ensure you
schedule a meeting with the Department of Water & Wastewater during the planning phase for this site. Additional impact fees
may apply for future development.
ADVISORY COMMENTS TO THE APPLICANT
WATER / WASTEWATER / GENERAL
1. None
I F Y OU H AVE A NY Q UESTIONS OR N EED TO D ISCUSS ANY OF THE A BOVE C OMMENTS , P LEASE C ALL THE A BOVE C ONTACT P ERSON AND THE
P LANNING D EPARTMENT AS S OON AS P OSSIBLE .
65
Page 66
Item 6.
CITY OF DOVER
DEVELOPMENT ADVISORY COMMITTEE
APPLICATION REVIEW COMMENTARY
STAFF D.A.C. MEETING DATE: APRIL 7, 2021
APPLICATION: Lands of Silver Linings Holding Corporation at 630 W.
Division St
FILE #: Z-21-03
REVIEWING AGENCY: City of Dover Electric Department
CONTACT PERSON: Paul Waddell, Electric Director
CONTACT PHONE #: 302-736-7072
CONTACT EMAIL #: pwaddell@dover.de.us
T HE S UBJECT P ROPOSAL HAS BEEN R EVIEWED FOR C ODE C OMPLIANCE , P LAN C ONFORMITY AND C OMPLETENESS IN
A CCORDANCE WITH THIS A GENCY ’ S A UTHORITY AND A REA OF E XPERTISE .
T HE F OLLOWING I TEMS HAVE BEEN I DENTIFIED AS E LEMENTS W HICH N EED TO BE A DDRESSED BY THE A PPLICANT :
CITY AND STATE CODE REQUIREMENTS
ELECTRIC
Our office has no objection to the rezoning of: ED-05-076.08-01-40.01-000
RECOMMENDATIONS SUGGESTED AS CONDITIONS OF APPROVAL TO MEET CODE OBJECTIVES
ELECTRIC
1. Should this site be redeveloped, which includes modifications to the use, the applicant / developer will be
responsible for all costs associated with providing the appropriate meter / service to this site based upon the
use including any necessary system upgrades or extensions. The appropriateness and adequacy of electric and
meters will be assessed at that time.
2. Any redevelopment shall adhere to the City of Dover’s Electric Service Handbook.
https://evogov.s3.amazonaws.com/media/27/media/13108.pdf.
ADVISORY COMMENTS TO THE APPLICANT
ELECTRIC
1. None.
I F Y OU H AVE A NY Q UESTIONS OR N EED TO D ISCUSS ANY OF THE A BOVE C OMMENTS , P LEASE C ALL THE A BOVE C ONTACT
P ERSON AND THE P LANNING D EPARTMENT AS S OON AS P OSSIBLE .
66
Page 67
C F
Z-21-03
Item 6.
I I
T R
CITY OF DOVER Y E
DEVELOPMENT ADVISORY COMMITTEE O M
F A
APPLICATION REVIEW COMMENTARY
R
D.A.C. MEETING DATE: 04/07/21 D S
O H
V A
E L
R
APPLICATION: Lands of Silver Linings Holding Corporation at 630 W Division St
FILE #: Z-21-03 REVIEWING AGENCY: City of Dover, Office of the Fire Marshal
CONTACT PERSON: Jason Osika, Fire Marshal PHONE #: (302) 736-4457
THE SUBJECT PROPOSAL HAS BEEN REVIEWED FOR CODE COMPLIANCE, PLAN CONFORMITY, AND
COMPLETENESS IN ACCORDANCE WITH THIS AGENCY’S AUTHORITY AND AREA OF EXPERTISE.
THE FOLLOWING ITEMS HAVE BEEN IDENTIFIED AS ELEMENTS WHICH NEED TO BE ADDRESS BY THE
APPLICANT:
CITY AND STATE CODE REQUIREMENTS:
1. This office has no objections regarding the proposed rezoning.
2. The installation of natural gas and LP gas meters, regulators, valves, and LP gas bottles shall be
protected from impact damage by impact protection. Natural gas and LP gas meters, regulators,
and valves located inside structures shall have impact protection, except when located in
separate protected utility rooms.
Dimensions of bollards. Bollards shall be a minimum of six-inch diameter filled with concrete. The
bollard shall be set into the ground at a depth of at least 36 inches (three ft.) embedded in
concrete at a minimum of 18 inches surrounding the bollard. The bollards must be a least 48
inches (four ft.) in height above the finish grade elevation. Any deviation of the stated
requirements must be approved by the fire marshal and/or chief building inspector. The above
dimensions shall serve as the requirement for installation; however, the fire marshal and/or chief
building inspector shall have the authority to require more stringent dimensions to fit the needs
of devices warranting impact protection.
Color of bollards. Bollards should be of the following colors; yellow, amber or orange. All colors
shall be of fluorescent or have a reflective coating. Any deviation of the stated requirements must
be approved by the fire marshal and/chief building inspector.
(City of Dover Code of Ordinances, 46-4)
3. Every house, building or structure used or intended for use as living quarters or as a place for
conducting business, and having any wall facing or abutting any public or private street or alley,
shall have displayed on that wall, in legible, easily read characters which are of contrasting color
67
Page 68
Item 6.
to the background, the proper street number for such house, building, or structure in accordance
with the following:
One-family and two-family residential structures, height, the number shall measure a minimum of four
inches in height, location, the number shall be placed on the house above or to the left or right of
the front entrance, color, the number shall be contrasting to the background color, Arabic numerals,
all numbers shall be Arabic numerals.
Multiple-family dwellings, measurements, the number shall measure a minimum of six inches when
identifying individual apartments with exterior doors, and 12 inches when identifying buildings
with apartment complexes where there are two or more buildings not assigned street addresses.
Individual buildings with street addresses shall have numbers measuring six inches, location,
numbers shall be placed either in the center of the building or on the street end of the building so
as to be visible from either the public or private street or from the parking lot, color, numbers shall
be contrasting to the background color, Arabic numerals, all numbers used shall be Arabic
numerals.
Commercial, industrial and office buildings, height, the numbers shall measure a minimum of 12 inches in
height, location generally, numbers shall be placed either in the center of the building or on the
street end of the building so as to be visible from either the public or private street or from the
parking lot,
property line or driveway, should the building be located far enough from a public or private road so
that the numbers are not clearly visible from the street, then the street address shall also be
posted on the property at or near the property line or driveway to said building,
color; each building, numbers shall be contrasting to the background color and shall be placed on
each building in the complex,
Arabic numerals, all numbers used shall be Arabic numerals,
Shopping centers. Shopping centers consisting of two or more stores shall have a tenant or suite
number affixed to the front of the tenant space and on the outside of the rear door which
corresponds with that tenant space. Numbers shall measure six inches in height.
(City of Dover Code of Ordinances, 98-344)
4. All required means of egress shall have an exit discharge consisting of a non-slip surface and
leading to and terminating at a public way.
5. Project to be completed per approved Site Plan.
6. Full building and fire plan review is required if there is a change in occupancy classification or if
renovations are proposed.
7. Separate building permits/plans submission will be required for each building and/or tenant fit
out. If the permit submission is for a “shell” a Certificate of Occupancy will not be issued.
Separate plans and permits submissions will be required for each “tenant fit out” at which time a
Certificate of Occupancy will be issued upon compliance/completion of each “tenant fit out”.
68
Page 69
Item 6.
Each “shell” will require a fire permit for sprinkler and fire alarm if applicable. Those systems (for
the “shell”) must be accepted into service prior to any “tenant fit out” fire permits being issued.
8. Construction or renovations cannot be started until building plans are approved.
9. Fire alarm systems, fire suppression systems, hoods, exhaust ducts, and hood suppression
systems require a fire permit from the Fire Marshal’s Office. This work cannot be started until
the permit is approved.
ADDITIONAL / SPECIFIC REQUIREMENTS TO OBTAIN APPROVAL:
1. Proposed future occupancy classification is unknown. Once determined, additional
comments may apply.
2. There was site work completed without proper approvals. Please obtain proper approvals
and correct the site work (currently interferes with egress from the building, see item # 4
listed above).
APPLICABLE CODES LISTED BELOW (NOT LIMITED TO):
2015 NFPA 1 Fire Code (NFPA; National Fire Protection Association)
2015 NFPA 101 Life Safety Code (NFPA; National Fire Protection Association)
2013 NFPA 72 National Fire Alarm and Signaling Code (NFPA; National Fire Protection Association)
2013 NFPA 13 Installation of Sprinkler Systems (NFPA; National Fire Protection Association)
2009 IBC (International Building Code)
Latest editions of all other NFPA Codes as defined by the Delaware State Fire Prevention Regulations
2015 Delaware State Fire Prevention Regulations
City of Dover Code of Ordinances
*If you have any questions or need to discuss any of the above comments, please call the above
contact person listed.
69
Page 70
Item 6.
CITY OF DOVER D
E
DEVELOPMENT ADVISORY COMMITTEE
L
APPLICATION REVIEW COMMENTARY D
O
T
===============================================================
APPLICATION: Silver Linings (630 W. Division Street)
FILE#: Z-20-03 REVIEWING AGENCY: DelDOT
CONTACT PERSON: Joshua Schwartz PHONE#: 302-760-2768
===============================================================
THE SUBJECT PROPOSAL HAS BEEN REVIEWED FOR CODE COMPLIANCE, PLAN CONFORMITY AND COMPLETENESS IN
ACCORDANCE WITH THIS AGENCY'S AUTHORITY AND AREA OF EXPERTISE.
THE FOLLOWING ITEMS HAVE BEEN IDENTIFIED AS ELEMENTS WHICH NEED TO BE ADDRESSED BY THE APPLICANT:
CITY & STATE CODE REQUIREMENTS:
No person, firm, corporation or the like shall construct, open, reconstruct, maintain, modify or use any
crossing or entrance onto a state-maintained highway, street or road, including any drainage modifications
leading into or carried by the highway drainage system, without first having complied with standards and
regulations adopted by the Department and having obtained a permit issued by the Department.
Please contact the Delaware Department of Transportation - Development Coordination section to begin
permit process.
RECOMMENDATIONS SUGGESTED AS CONDITIONS OF APPROVAL TO MEET CODE
OBJECTIVES:
ADVISORY COMMENTS TO THE APPLICANT:
1. No Objection to the Rezoning.
2. The developer should contact DelDOT to schedule a pre-submittal meeting.
3. It is expected a Record Plan and Entrance Plan Review will be required.
4. A cross-access easement should be established to a neighboring parcel.
5. DelDOT Project T201630003 is in front of the property. This project involves the
design of a multi-use trail facility and or dedicated bike boulevard along the Rt. 8
corridor from US13 to a point near the new Dover High School.
70
Page 71
KENT CONSERVATION DISTRICT
Item 6.
1679 SOUTH DUPONT HIGHWAY • DOVER, DELAWARE 19901• (302) 608-5370 • WWW.KENTCD.ORG
CITY OF DOVER
DEVELOPMENT ADVISORY COMMITTEE
APPLICATION REVIEW COMMENTARY
April 2021
APPLICATION: Lands of Silver Linings Holding Corporation at 630 W Division Street
FILE #: Z-21-03
REVIEWING AGENCY: Kent Conservation District
CONTACT PERSON: Kate Owens PHONE #: 302-608-5370
THE SUBJECT PROPOSAL HAS BEEN REVIEWED FOR CODE COMPLIANCE, PLAN CONFORMITY
AND COMPLETENESS IN ACCORDANCE WITH THIS AGENCY’S AUTHORITY AND AREA OF
EXPERTISE. THE FOLLOWING ITEMS HAVE BEEN IDENTIFIED AS ELEMENTS WHICH NEED TO
BE ADDRESSED BY THE APPLICANT:
Source: 2019 Delaware Sediment and Stormwater Regulations
CITY AND STATE CODE REQUIREMENTS:
Kent Conservation District has no objection to the proposed rezoning of the above referenced site.
ADVISORY COMMENTS TO THE APPLICANT:
Soil disturbance (e.g. clearing, grading, excavations, tree clearing, or stoning) equal to or greater than 5,000
square feet requires a Sediment and Stormwater Management Plan to be submitted and approved by the Kent
Conversation District prior to the commencement of disturbance.
71
Page 72
City of Dover Application No.: Z-21-03
Item 6.
Department of Planning & Inspections
IPM RG-1
M
C-2A
t
est S
NW
C-3
ely S C-3
Ridg
C-3
M t
est
SW
C-2A
St
S t
r IO ivis ion
ton D
WD
Wes C-2A
Site
C-3
C-1A
Fore
st St
C-1
C-1A
IO
RG-1
RG-1 C-3
Lincoln St
Cherry St
IO
Davis Cir
RG-1 C-3
RG-1
R-8 R-8
Tile: Lands of Silver Linings Holding Corp.
Ordinance #: 2021-07
Addresses: 630 W. Division Street Legend
«
Parcel ID: ED-05-076.08-01-40.01-000
Subject Property
Existing Zoning: C-3 Service Commercial Zone and
COZ-1 Corridor Overlay Zone 2012 Buildings
Proposed Zoning: C-2A Limited Central Commercial Zone
Zoning
COZ-1 Corridor Overlay Zone
Owner: Tolando D. Anderson, Silver Linings Holding Corp. Dover Parcels
Date: 03/11/2021
Corridor Overlay Zone
0 100 200 400 Feet
72
Page 73
Item 6.
REVISED
REQUEST:
No Equitable Owner
Listed
REVISED REQUEST: Limited Central Commercial Zone (C-2A)
Corridor Overlay Zone (C0Z-1)
REVISED REQUEST: To be Rezoned from C-3 to C-2A
SUBMISSION PLAN
SHEET REVISED FOR
NEW REZONING
APPLICATION
73
Page 74
Item 7.
City of Dover
DATA SHEET FOR SITE DEVELOPMENT MASTER PLAN REVIEW
ADDENDUM to DEVELOPMENT ADVISORY COMMITTEE REPORT from
MEETING OF October 7, 2020
PLANNING COMMISSION MEETING OF April 19, 2021
Plan Title: Bayhealth Staff Parking Lot Expansion at Scull Property, S-20-10
Plan Type: Site Development Master Plan
Plan Addendum: Revision to Phase 1 (dated March 25, 2021)
Property Location: East side of South State Street in block between South Street and Scull
Terrace
Property Addresses: 605 South State Street, 625 South State Street, 100 Scull Terrace,
and 150 Scull Terrace
Tax Parcels: ED-05-077.13-01-49.00-000 and ED-05-077.13-01-51.00-000
Owner: Bayhealth Medical Center, Inc.
KGH Development Corporation
Present Zoning: IO (Institutional and Office Zone)
SWPOZ (Source Water Protection Overlay Zone): Tier 1 & Tier 3
Existing Uses: Existing Buildings as Offices, Surgery Center, and Day Care Center
with Parking Lots (227 existing parking spaces)
Proposed Uses: Expansion of Parking Lots with removal of buildings:
Phase 1 (Revised): Demolish Office Building (Gates Building) and
various Maintenance Accessory Buildings; Proposal to Retain Scull
Mansion Building for Period of 18 months; add 251 parking spaces
Phase 2: Demolish Day Care Center Building; add 72 parking spaces
Phase 3: Demolish Surgery Center Building; add 91 parking spaces
and add connection to S. State Street at South Street intersection
Site Area: 11.43 acres
Waivers Requested: Partial Elimination of Curbing
Elimination/Relocation of Bicycle Parking
Elimination of Opaque Barrier Component
For Consideration: Utilize Joint Parking Facilities provisions
P. O. Box 475 Dover, DE 19903 74
Community Excellence Through Quality Service
Page 75
Item 7.
S-20-10 Bayhealth Staff Parking Lot Expansion at Scull Property (Revision of March 25, 2021)
Addendum to DAC Report of October 7, 2020
APPLICATION: Bayhealth Staff Parking Lot Expansion at Scull Property: Master Plan (Revision
of March 25, 2021)
FILE #: S-20-10
1. APPLICATION STATUS
Site Development Master Plan Application S-20-10 Bayhealth Staff Parking Lot Expansion at
Scull Property began its application review in the Fall of 2020 and was scheduled to be heard by
the Planning Commission on October 19, 2020. By letter of October 16, 2020, the applicant
requested that the Planning Commission to defer the Public Hearing and consideration of
Application S-20-10 from the October 19, 2020 Meeting. The Planning Commission in adopting
the Meeting Agenda in October 2020 acted to remove Application S-20-10 from
consideration. Following this postponement, the Consideration and Public Hearing for
Application S-20-10 Bayhealth Staff Parking Lot Expansion at Scull Property was to be
rescheduled for a future Planning Commission meeting when the applicant sought to continue its
review. The Application S-20-10 is required to be subject to Public Notice requirements for the
Public Hearing on the new meeting date. The Applicant has made the request to return to the
Planning Commission.
2. ADDENDUM – PLAN REVISION RECEIVED
On March 25, 2021, the Planning Office received a Letter of Request to rejoin the Planning
Commission review process for Site Development Master Plan S-20-10 Bayhealth Staff Parking
Lot Expansion at Scull Property. The Letter of March 25, 2021 outlined a series of actions the
applicant had taken including meetings with neighbors and interested parties. The submission
Letter and attached Revised Plan Sheet C-201 outlined a series of revisions for the proposed
project specifically related to Phase 1. See the Revised Plan Sheet C-201 and the original Plan
Set submission of October 2020.
3. PROJECT DESCRIPTION - REVISED
This Site Development Master Plan proposes three (3) phases of the project for the Bayhealth
Staff Parking Lot Expansion at Scull Property. The subject area consists of 2 parcels of land
including the following addresses: 605 S. State Street, 625 S. State Street, 100 Scull Terrace, and
150 Scull Terrace. Overall, the project involves the following (as Revised March 25, 2021):
• Phase 1 (Revised): Demolition of the the previous Gates Residence, and three other
structures (related to maintenance, etc.). The Scull Mansion Building is proposed to be
retained for a period of Reconfiguration of existing parking lot layout and construction of
251 new parking spaces. Total of 478 Parking Spaces on site with three buildings.
• Phase 2: Demolition of the Day Care Center Building. Construction of 72 new parking
spaces. Total of 589 Parking Spaces on site with one building.
75
Page 76
Item 7.
S-20-10 Bayhealth Staff Parking Lot Expansion at Scull Property (Revision of March 25, 2021)
Addendum to DAC Report of October 7, 2020
• Phase 3: Demolition of the Surgery Center Building. Construction of 91 parking spaces.
Construction of connecting drive aisle to South State Street. Total of 680 Parking Spaces
on site with no buildings.
In general, the application (as Revised) proposes construction of several parking lot areas on the
property after demolition of certain buildings located in the phase project area. The existing
parking lot located around the Scull Mansion Building and to the west of Outpatient Surgery
Center following demolition of four buildings will be expanded to the west and north. This
extends to the north also encompassing the Gates House area following its demolition. The Scull
Mansion Building is shown as retained in Phase 1; see Revised Plan Sheet C-201 dated March
25, 2021. The applicant notes that retaining the Scull Mansion Building will eliminate thirty-nine
(39) parking places previously planned for this area. This Phase 1 Parking Lot will consist of 452
parking spaces with an additional 26 spaces remaining near the Day Care Center Building. The
only access to the parking lot is from Scull Terrace during Phases 1 and 2.
Phase 2 involves the demolition of the Day Care Center Building and construction of new
parking spaces in its place. Phase 3 involves the demolition of the Surgery Center Building for
the creation of addition parking spaces and construction of a connecting drive aisle to South
State Street at the northern portion of the site (opposite South Street intersection).
4. PREVIOUS D.A.C. REVIEW REPORT
The previous Development Advisory Committee (D.A.C.) Report and Comments dated October 7,
2020 are included for Application S-20-10. This Review Report and Comments is still valid when
considering the Revised Submission and should be referenced for information on review of the
overall Application S-20-10. The Applicant has only revised the project proposal for activities
within Phase 1 of the Master Plan.
The following Waiver Requests and Item for Consideration are to be acted upon with the Site
Development Master Plan S-20-10 Revised. See D.A.C. Report for code explanations and copies of
the Applicant’s request documents.
• Waivers Requested: Partial Elimination of Curbing
Elimination/Relocation of Bicycle Parking
Elimination of Opaque Barrier Component
• For Consideration: Utilize Joint Parking Facilities provisions
The Review Comments and items offered by the Planning Office as identified in the D.A.C. dated
October 7, 2020 under the following sections remain valid:
• VII. CITY AND STATE CODE REQUIREMENTS
• VIII. RECOMMENDATION SUGGESTED AS CONDITIONAL OF APPROVAL TO
MEET CODE OBJECTIVES
• IX. ADVISORY COMMENTS TO THE APPLICANT
76
Page 77
Item 7.
City of Dover
DATA SHEET FOR SITE DEVELOPMENT MASTER PLAN REVIEW
DEVELOPMENT ADVISORY COMMITTEE MEETING OF October 7, 2020
PLANNING COMMISSION MEETING OF October 19, 2020
Plan Title: Bayhealth Staff Parking Lot Expansion at Scull Property, S-20-10
Plan Type: Site Development Master Plan
Property Location: East side of South State Street in block between South Street and Scull
Terrace
Property Addresses: 605 South State Street, 625 South State Street, 100 Scull Terrace,
and 150 Scull Terrace
Tax Parcels: ED-05-077.13-01-49.00-000 and ED-05-077.13-01-51.00-000
Owner: Bayhealth Medical Center, Inc.
KGH Development Corporation
Present Zoning: IO (Institutional and Office Zone)
SWPOZ (Source Water Protection Overlay Zone): Tier 1 & Tier 3
Existing Uses: Existing Buildings as Offices, Surgery Center, and Day Care Center
with Parking Lots (227 existing parking spaces)
Proposed Uses: Expansion of Parking Lots with removal of buildings
Phase 1: Demolish Office Buildings (Scull Mansion and Gates
Building) and various Maintenance Accessory Buildings; add 290
parking spaces
Phase 2: Demolish Day Care Center Building; add 72 parking spaces
Phase 3: Demolish Surgery Center Building; add 91 parking spaces
and add connection to S. State Street at South Street intersection
Site Area: 11.43 acres
Waivers Requested: Partial Elimination of Curbing
Elimination/Relocation of Bicycle Parking
Elimination of Opaque Barrier Component
For Consideration: Utilize Joint Parking Facilities provisions
P. O. Box 475 Dover, DE 19903 77
Community Excellence Through Quality Service
Page 78
City of Item 7.
Dover
Planning
CITY OF DOVER Office
DEVELOPMENT ADVISORY COMMITTEE
APPLICATION REVIEW COMMENTARY
D.A.C. MEETING DATE: October 7, 2020
APPLICATION: Bayhealth Staff Parking Lot Expansion at Scull Property: Master Plan
FILE #: S-20-10 REVIEWING AGENCY: City of Dover Planning
CONTACT PERSON: Dawn Melson-Williams, AICP PHONE #: (302) 736-7196
I. PLAN SUMMARY
This Application is for Review of a proposed Site Development Master Plan to permit
construction of 453 new parking spaces over the course of three phases for the Bayhealth
Medical Center Campus. This Bayhealth Staff Parking Lot Expansion expands the existing
parking from 227 spaces to a total of 680 parking spaces on the area collectively known as the
Scull Property. Phase 1 proposes 290 parking spaces; Phase 2 proposes 72 new parking spaces
and Phase 3 proposes an additional 91 parking spaces and a connection to S. State Street at the
South Street intersection. The Plan shows the demolition of existing buildings in each phase for a
total of seven (7) buildings demolished including the Scull Mansion to accommodate the
increased volume of parking. In total the properties measure 11.43 acres +/- and are located on
the east side of S. State Street in the block between South Street and Scull Terrace. The
properties are zoned IO (Institutional and Office Zone) and subject to the SWPOZ (Source Water
Protection Overlay Zone). The owners of record are Bayhealth Medical Center, Inc. and KGH
Development Corp. The parcels are proposed to be consolidated before the project
begins. Property Addresses: 605 S. State Street, 625 S. State Street, 100 Scull Terrace, and 150
Scull Terrace. Tax Parcel Numbers: ED-05-077.13-01-49.00-000 and ED-05-077.13-01-51.00-
000. Council District 2.
Previous Applications
Site Plan S-13-05 Lands of KGH Development Corp.
The site was the subject of Site Plan S-13-05 Lands of KGH Development Corp. at 625 S. State
Street: Parking Lot Construction in 2013. At its meeting of May 20, 2013 (after deferring action
at their April 15, 2013 Meeting seeking additional information), the City of Dover Planning
Commission granted conditional approval of the Site Plan S-13-05 for the expansion of the
existing parking lot at 625 South State Street, known as the Scull Mansion property, to add one
hundred-thirty (130) parking spaces. The action included approval of a Curbing Waiver and also
added conditions to require elimination of certain parallel parking spaces along the Scull Terrace
entrance drive.
Also, with Site Plan S-13-05, the Planning Commission approved the use of the Joint Parking
Facilities provisions of Zoning Ordinance, Article 6 §3.7. This allowed the parking to be viewed
78
Page 79
Item 7.
S-20-10 Bayhealth Staff Parking Lot Expansion at Scull Property
DAC Report of October 7, 2020
Page 2
on a facility-wide approach for the Bayhealth Medical Center properties where the parking lots
may serve two or more establishments that are not located on the same parcel. The Commission
accepted the information on employee count (for the parking calculation) and the Parking
Exhibit Plan giving information existing parking facilities (as of 2013). The new spaces of the
parking lot expansion developed under S-13-05 contribute toward the overall parking
requirements for the Bayhealth Medical Center facilities.
Master Plan S-06-14 Bayhealth Medical Center:
A Master Plan was previously developed for the main campus area of the Bayhealth Medical
Center at 640 South State Street. The project area for the Bayhealth Medical Center Master Plan
consisted of multiple parcels of land located between South State Street and South Governors
Avenue in the vicinity of South Street and Hope Street; it did not include this area on the east
side of South State Street. However, the property was later included in a Unified Comprehensive
Signage Plan for the Bayhealth Medical Center facilities (US-11-01).
The Bayhealth Medical Center Kent Campus Master Plan (S-06-14) was approved in June 2006
with a one-year extension to the project in May 2007. Revisions to the Master Plan approved in
September 2007 related to a Pedestrian & Utility Bridge over South Street rather than a tunnel as
first proposed. The four phases of the Master Plan consisted of the following:
• Phase 1: Central Services Building
• Phase 2: Podium Building, Parking Garage, and Pedestrian & Utility Bridge
• Phase 3: South Street Parking Lot improvements
• Phase 4: Seven-story Bed Tower Building Addition and north Parking Garage
After some revisions to the construction sequencing, the following phases have been completed:
S-08-20 Phase 1- Podium Building and Parking Garage and S-08-42 Phase 2A – Central Services
Building and Pedestrian & Utility Bridge. Administrative Site Plan review was completed in
August 2009 for S-09-02 Phase 2B – South Street Parking Lot Improvements but not started. A
proposed north Parking Garage (in Phase 4) was not built.
Other History of Property Development
The Scull Mansion (named after its 20th century owner), now utilized as an office building, was
constructed circa 1864 by Manlove Hayes as a residence. The northernmost brick Cape Cod
Style building constructed mid-20th century was previously a residential dwelling (Gates House)
prior to being acquired by Bayhealth. The two easternmost buildings on the subject property
were developed with Applications C-90-1 KGH Surgery Center & Diagnostic Center and C-90-
12 KGH Paramedic Training Center.
II. PROJECT DESCRIPTION
This Site Development Master Plan proposes three (3) phases of the project for the Bayhealth
Staff Parking Lot Expansion at Scull Property. The subject area consists of 2 parcels of land
including the following addresses: 605 S. State Street, 625 S. State Street, 100 Scull Terrace, and
150 Scull Terrace. Overall, the project involves the following:
• Phase 1: Demolition of the Scull Mansion building, the previous Gates Residence, and
three other structures (related to maintenance, etc.). Reconfiguration of existing parking
lot layout and construction of 290 new parking spaces. Total of 517 Parking Spaces on
site with two buildings.
79
Page 80
Item 7.
S-20-10 Bayhealth Staff Parking Lot Expansion at Scull Property
DAC Report of October 7, 2020
Page 3
• Phase 2: Demolition of the Day Care Center Building. Construction of 72 new parking
spaces. Total of 589 Parking Spaces on site with one building.
• Phase 3: Demolition of the Surgery Center Building. Construction of 91 parking spaces.
Construction of connecting drive aisle to South State Street. Total of 680 Parking Spaces
on site with no buildings.
In general, the application proposes construction of several parking lot areas on the property after
demolition of the buildings located in the phase project area. The existing parking lot located
around the Scull Mansion Building and to the west of Outpatient Surgery Center following
demolition of five buildings will be expanded to the west and north. This extends to the north
also encompassing the Gates House area following its demolition. This Phase 1 Parking Lot will
consist of 491 parking spaces with an additional 26 spaces remaining near the Day Care Center
Building. The only access to the parking lot is from Scull Terrace during Phases 1 and 2. Phase
2 involves the demolition of the Day Care Center Building and construction of new parking
spaces in its place. Phase 3 involves the demolition of the Surgery Center Building for the
creation of addition parking spaces and construction of a connecting drive aisle to South State
Street at the northern portion of the site (opposite South Street intersection).
Located on this property, the two-story stucco clad building originally constructed as a mansion
house now utilized as offices is proposed for demolition with this Parking Lot Expansion. The
building is known as Greenwold (K-00126) and also known as the Manlove Hayes House
(original owner) and Scull Mansion (20th century property owner). It is listed on the National
Register of Historic Places.1 Manlove Hayes, a local businessman and state legislator, was also
involved with the Delaware Railroad Company. Constructed circa 1863-1864, this house set on
the edge of Dover in a pastoral setting; the house and its property included other outbuildings, a
front carriage drive, and a planned landscape design.
III. ZONING REVIEW
IO Zoning District
The subject properties are zoned IO (Institutional and Office Zone) and subject to the regulations
of Zoning Ordinance, Article 3 Section 10 and Article 4 Section 4.15. The proposed use as off-
street parking (a parking lot) is associated with the on-site medical building and Day Care Center
(until their demolition) and the larger Bayhealth Medical Center campus located to the west of
South State Street.
SWPOZ (Source Water Protection Overlay Zone)
Portions of the site are located within the SWPOZ (Tier 3: Excellent Recharge Area and Tier 1:
Secondary Wellhead Protection Area) found in Article 3 Section 29.7 of the Zoning Ordinance.
However, this project site is within the Downtown Redevelopment Target Area which is exempted
from the SWPOZ requirements and restrictions as per Zoning Ordinance, Article 3 §29.79 for the
Tier 3 area. The area subject to the Tier 1 requirements does not appear to be located within the
project area for the new parking lot expansions.
1
Greenwold (K-00126) also known as the Manlove Hayes House was listed on the National Register of Historic
Places on March 20, 1973. This central hall plan residence is noted as being constructed by Richard D. Smithers and
as having a landscape design planned by William Saunders. The property was also the subject of a series of
photographs as HABS No. DE-198 in July 1982.
80
Page 81
Item 7.
S-20-10 Bayhealth Staff Parking Lot Expansion at Scull Property
DAC Report of October 7, 2020
Page 4
Site Development Master Plan
The plan for this project is submitted for review under the Site Development Master Plan process
(See Zoning Ordinance, Article 10 §2.44 listed below). This process allows for a series of
construction phases to be outlined in a Master Plan for Planning Commission review and
approval. Prior to each Phase of construction, a Site Plan specific to that phase is submitted for
Administrative Site Plan review.
Article 10 §2.44 Site development master plans. Conceptual site development master plans shall
be reviewed by the planning commission in accordance with the provisions of subsection 2.43.
Conceptual site development master plans shall depict a site development proposal that reflects
general compliance with the provisions of the zoning ordinance and shall also reflect the following
information on the plan:
(A) Conceptual Master Plan. Conceptual Master Plan shall include the proposed general
layout of building, streets, parking, open space, landscape concepts, and stormwater
management areas.
(1) Detailed site construction plans, details, and specifications are not required as
part of a site development master plan submission.
(2) The plan shall illustrate distinct phase boundaries for each proposed construction
phase and shall depict proposed construction and site improvements planned for
each phase. Bulk quantities and area totals for each construction phase, and for
the total site, shall be tabulated in a data column on the plan.
(3) Each construction phase shall be enumerated in sequential order on the site
development master plan according to the order of construction contemplated by
the plan. Phases shall be implemented in accordance with the approved site
development master plan unless the city planner approves an alternate phasing.
(4) Each construction phase represented on the master plan shall be planned and
designed to function independent of construction and site improvements
contemplated in future construction phases in all respects, including but not
limited to bulk area provisions of the zoning district in which the site is located,
off-street parking requirements, site entrances, emergency access requirements,
site utilities, and stormwater management improvements except where the
requirements and needs of a later phase are met and remain met by a previous
phase of completed construction.
(5) Any special agreements or conditions of approval relative to the overall
development that have been specified by regulatory agencies shall be
documented on the site development master plan.
(B) Phased site plan approval. Individual phased components of the Conceptual Master
Plan are to be reviewed and approved as an Administrative Site Plan. Final site
construction plans, including detailed site grading, paving, utilities, stormwater
management, and tree planting and preservation plans shall be submitted for final
approval by the city planner and/or authorized designee, and to other agencies
having jurisdiction, on a phase by phase basis in accordance with the approved site
development master plan, and all regulations of the City of Dover governing the
approval of site plans as set forth in subsection 2.4 and 2.5.
IV. PARKING SUMMARY
The parking requirements for a property in the IO zone is one parking space per 300 S.F. of floor
area or one per employee, whichever is greater. A Day Care Center requires parking at a rate of
one parking space per adult attendant and one parking space per ten (10) children. It is noted that
the minimum off street parking requirement for the hospital use is based on one (1) space per
every three (3) beds in the facility (Zoning Ordinance, Article 6 § 3.1).
81
Page 82
Item 7.
S-20-10 Bayhealth Staff Parking Lot Expansion at Scull Property
DAC Report of October 7, 2020
Page 5
Based on the size of the surgery center building totaling 10,800 S.F. results in a requirement of
thirty-six (36) parking spaces for it. The current tally of attendants and children in the Day Care
Center was not provided but from 2013 information the building required twenty-seven (27)
parking spaces. The existing parking on the subject property serves these building and more. It
appears that the Parking Lot Expansion is intended to serve the larger Bayhealth Medical Center
campus.
Consideration of Joint Facilities for Parking
The Zoning Ordinance includes provisions for considerations of parking to jointly serve multiple
establishments which could be considered for this property.
Article 6 Section 3.7 Joint facilities. Required parking spaces, open or enclosed, may be provided
in spaces designed to serve, jointly, two or more establishments, whether or not located on the
same lot, provided that the number of required spaces in such joint facilities shall be not less than
the total required for all such establishments.
The applicant listed on the Plan a summary of the overall parking provided for the Bayhealth
Medical Center properties. The plan lists a total of 1,601 parking spaces available for the campus
and a total number of employees is 2,052 employees. The Scull Property existing and proposed
by phases parking is given; however, the specific details of on-campus and off-campus parking
locations are not provided. See Parking Summary – Bayhealth Medical Center Campus Chart on
Plan Sheet C-001. Additionally, a submitted narrative titled “Parking Lot Expansion Necessity”
describes the parking needs of the Bayhealth Kent Campus; see submission.
Bayhealth Medical Center Campus Parking Summary:
Previous projects implemented on the Bayhealth Medical Center campus included construction
of a parking garage, new surface parking lots, and improvements to existing parking lots. With
Site Plan S-13-05, a Parking Exhibit Plan (dated 4/2/2012) identified the locations of the campus
buildings and associated parking facilities in order to utilize the provisions for joint facilities
parking. The following table is provided as reference.
Existing Parking Facilities at Bayhealth Medical Center Campus (from S-13-05 Plan)
Location Address Number of Parking Spaces
Scull Property 625 South State Street 227**
Gates Property 605 South State Street 8**
Bayhealth Hospital (main 640 South State Street 492 Total:
building) 12 at Frear House
8 at front entrance
371 in Parking Garage
17 Emergency Room
84 Staff Parking Lot
North of South Street Governors Avenue 483 Total:
26 at Office Building
56 at Central Service Building
401 South Street Parking Lot
Hope Street Parking Lot Southeast corner of Hope Street 157
and South Governors Avenue
Human Resources Office 600 South Governors Avenue 49
Medical Office Buildings 540 & 560 South Governors 184
Avenue
** Updated to current parking lot count at subject site as shown on S-20-10.
82
Page 83
Item 7.
S-20-10 Bayhealth Staff Parking Lot Expansion at Scull Property
DAC Report of October 7, 2020
Page 6
Loading Spaces
Institutional buildings require loading spaces at rate of one space per 10,000 SF and one space per
each additional 25,000 SF. The plan shows several loading spaces on the south side of the Surgery
Center Building to satisfy this requirement (until building is demolished in Phase 3).
Bicycle Parking
Waiver Request: Elimination/Relocation of Bicycle Parking
The project is required to provide bicycle parking. The bicycle parking calculation is one for
every twenty parking spaces. Based on the total of 680 parking spaces ultimately on this parcel,
thirty-four (34) bicycle parking spaces are required. Each phase would be required to satisfy the
bicycle parking coinciding with the number of vehicle parking spaces. Existing bicycle parking
spaces were not identified. A written Waiver Request was received for consideration by the
Planning Commission to relocate the required bicycle parking from this Parking Lot Expansion
project to the Bayhealth main campus at 640 S. State Street citing it as the destination of bicycle
riders. However, details of the existing bicycle parking locations and format are provided in a
photographic exhibit. See attached Waiver Request and Exhibit: Bayhealth Bicycle Racks.
Waiver Request: Partial Elimination of Upright Curbing
The upright curbing for parking lots and drive aisles is required per the requirements of Article 6
Section 3.6(b) of the Zoning Ordinance. This curb type appears to be utilized throughout the
parking lot construction area with the exception of a segment of existing parking to remain and
the future location of the Phase 3 connecting drive aisle. A written Waiver Request for the
elimination of curbing was submitted to the Planning Office for consideration citing the reasons of
the stormwater runoff. The City Planner can consider requests to eliminate curbing when there is
a demonstrated need related to stormwater management. See attached Waiver Request.
V. SITE CONSIDERATIONS
This subject site includes area of significant topographic change. The northern portion of the
property slopes towards a floodplain area (and culvert contained Meeting House Branch). Also,
the property is higher than the adjacent roadways in certain areas.
Adjacent to St. Jones River
A portion of the property is adjacent to St. Jones for a section of its east property line. A setback
of 100 feet from this water body is required for development. The proposed Parking Lot
Expansion does not encroach in this area.
Wetland Areas
The property includes a wetland area in the northeast portion. Per the Zoning Ordinance, if the
wetland area is over 0.25 acres in size then a 100-foot setback is required. The proposed Parking
Lot Expansion does not encroach in this area.
Special Flood Hazard Areas
Portions of the northeastern and eastern boundary of the subject site are within the Special Flood
Hazard Area (100-year floodplain/ 1% annual chance of flood). This information is shown on the
FEMA FIRM Panel #10001C0169J effective date July 7, 2014. Zoning Ordinance, Article 5
83
Page 84
Item 7.
S-20-10 Bayhealth Staff Parking Lot Expansion at Scull Property
DAC Report of October 7, 2020
Page 7
§11.21 requires that flood hazard areas (100-year floodplain) remain as open natural areas with
no impervious surfaces. Currently, these areas are predominately wooded areas and no site
improvements are proposed in that area.
Access
The property is accessed by an entrance drive from South State Street. For addressing purposes,
this entrance drive is named Scull Terrace. The entrance drive is shared with the Holy Cross
Church and School Complex. This shared entrance drive was created in the late 1980’s and is
referenced in an Easement Agreement dated January 30, 1987 (Deed Book 47 Page 63).
Sidewalks
The project site has an existing sidewalk along the South State Street frontage. A single sidewalk
connects the parking lot to the corner at Scull Terrace. There are marked crosswalks across Scull
Terrace and then a pedestrian crosswalk system (pedestrian activated warning lights system)
across South State Street.
Lighting
The parking lot project does identify additional site lighting in the areas of the parking lot
expansion as pole lights. The proposed lighting must be adequate to safely light all parking and
pedestrian areas yet must be shielded and directed as to not create a nuisance on the adjacent
properties.
Scenic Resources
The Zoning Ordinance, Article 5 §11.25 on environmental protections recognizes Scenic
Resources and seeks consideration of them during the site development process. See excerpt
below.
Article 5 §11. Environmental protection
11.25 Scenic resources. Scenic resources shall consist of the following: mature woodlands
and most especially the edges of wooded areas adjacent to open fields, wetlands or urbanized
areas; other areas of mature natural vegetation such as marsh grasses; the historic district and
areas listed on the National Register of Historic Places ; and freestanding historic buildings and
sites and other buildings or districts of the city exhibiting particular architectural or visual merit
buildings and places of special public or cultural significance, and significant views and v iew
corridors to buildings or places of architectural, visual, public or cultural value and to attractive
natural areas. Application for subdivision plan or site development plan approval shall include,
as a part of the documentation of existing site conditions, the presence of and location of all
scenic resources. The preservation and enhancement of the scenic resources potentially
affected by the proposed development shall be considered by the planning commission in
development review.
As previously noted, the subject site includes the Scull Mansion Building which is listed on the
National Register of Historic Places. The Scull Mansion building is currently labeled as “Two
Story Stucco Building” on the plan. The Code calls for the Planning Commission to consider the
“preservation and enhancement of the scenic resources” affected by the proposes development.
The applicant submitted a narrative titled “Scenic, Historical, and Environmental Preservation.”
VI. TREE PLANTING AND LANDSCAPE PLAN
The submitted plan includes the Landscaping approach for the overall project. Zoning
Ordinance, Article 5, Section 16.62 offers the option of the applicant defining a “Development
84
Page 85
Item 7.
S-20-10 Bayhealth Staff Parking Lot Expansion at Scull Property
DAC Report of October 7, 2020
Page 8
Area” within the overall property for the purpose of tree planting calculations. The applicant has
established a “Development Area” for the project s shown on the Landscape Plan (Sheet L-101)
as a dashed black line.
With the tree planting requirement of one tree per 3,000 SF of Development Area, the
Development Area is estimated to require 106 new trees. Some existing trees along South State
Street will remain along with existing woodland areas in the eastern portions of the site. The
Landscape Plan is providing a mixture of trees to provide a total of 122 new trees on the site.
Mixed Planting of canopy trees, flowering trees, and evergreen trees are proposed within parking
lot islands and medians and at the parking lot perimeter.
Opaque Barrier
Waiver Request: Elimination of Opaque Barrier Component
Screening is required wherever a non-residential use abuts a residential use. This screening must
consist of an opaque barrier (a fence, wall, or berm) at least six feet in height, accompanied by
landscaping (Zoning Ordinance, Article 5 §7.2). This Opaque Barrier requirement applies to the
northern property line adjacent to the residential properties which front Elm Terrace as they are
zoned R-8 (One Family Residence Zone). The plan as submitted by the applicant does not
indicate the placement of an opaque barrier component (fence, wall or berm). They are some
areas of existing woodland and individual trees that may be utilized to comply with the
landscaping component of the barrier. A written Waiver Request was submitted focus on the
Opaque Barrier and Landscaping Requirement. Per Code, the landscaping component cannot be
waived.
VII. CITY AND STATE CODE REQUIREMENTS:
The subject proposal has been reviewed for Code compliance, plan conformity, and
completeness in accordance with this agency’s authority and area of expertise. The following
items have been identified as elements which need to be addressed by the applicant:
1) The Master Plan must reflect any changes recommended by the Planning Commission. Add
notes for any waivers or conditions acted upon by the Planning Commission.
2) Upright curbing shall be provided in accordance with the Zoning Ordinance. A waiver may
be granted by the City Planner if necessary, for stormwater management. An initial request
was made with this Master Plan submission and additional specific area requests may also be
identified with the Administrative Site Plan submissions for future phases.
3) Bicycle parking must be provided on the subject property unless a waiver for its relocation or
reduction is granted by the Planning Commission. A Waiver Request was submitted for
review including an Exhibit of the existing bicycle parking areas. If relocation of the bicycle
parking is accepted, then the Administrative Site Plan must include details of the
improvements of the bicycle parking location.
4) The property is subject to the requirements of the Opaque Barrier as this non-residential use
is adjacent to residential uses on the north. A written Waiver Request was submitted;
however, only the opaque barrier (fence, wall, or berm) component can be considered for
elimination. The landscaping component of the barrier must be satisfied.
85
Page 86
Item 7.
S-20-10 Bayhealth Staff Parking Lot Expansion at Scull Property
DAC Report of October 7, 2020
Page 9
5) This application appears to seek to utilize the joint facilities parking provisions of Zoning
Ordinance, Article 6 Section 3 for the subject site and the Bayhealth Medical Center campus.
A narrative titled “Parking Lot Expansion Necessity” will information on the required
parking for the hospital facilities and the existing parking conditions on the campus was
provided.
6) A separate Record Plan sheet was submitted to show parcel consolidations, all right-of-way
dedications, any easements, or other items affecting the property lines.
7) Sheet C-001:
a) Indicate the location of zoning SWPOZ (Source Water Protection Overlay Zone) Tier 3
and Tier 1 on the plan drawing.
b) The required setback on the north property line is 30 feet.
c) General Note #4: List Zone AE for property areas located in the floodplain.
d) General Note #13: Add deed reference information on the easement regarding the shared
entrance drive.
e) General Note #16: Identify that these notations (1-3AB) are applicable to Site Plan S-13-
05 and may be superseded by this current review. This Master Plan submission is subject
to a new and separate review by the Planning Commission.
f) Show the 100-foot Waterbody Buffer from the St. Jones River. Update on all plan sheets.
g) Clarify two floodplain lines on east side of site.
h) Label north property line of 605 S. State Street to be removed.
i) Clarify status of fence line from 605 S. State Street.
j) List all involved addresses in Site Data Item #3 and in title block listing.
8) Confirm that sidewalk leading from parking lot and handicapped parking area to the Scull
Terrace crossing meets accessibility requirements i.e. slope to allow those parking in this area
to utilize the pedestrian crossing to the main campus.
9) Ensure accessibility ramps provided at intersections of sidewalks with parking and drive aisles.
10) Sheet C-101 – Existing Conditions Plan:
a) Label location of Greenwold (K-00126) as listed on National Register of Historic Places.
b) Check parking tally as drawing appears to show 222 parking spaces rather than 227.
11) Sheets C-201 Series: The following items are noted for correction or addition and should be
provided on future Administrative Site Plan submissions.
a) Add accessibility ramps to sidewalk crossing points just east of Holy Cross entrance from
Scull Terrace.
b) Show bicycle parking for remaining buildings.
c) Add addresses to building drawing labels to help clarify locations.
d) Identify the location of any traffic control signage for the parking lots and handicapped
parking signage.
e) Remove curb cuts not utilized along South State Street.
f) Consider locations for additional connections from street frontage sidewalk to parking lot
areas.
86
Page 87
Item 7.
S-20-10 Bayhealth Staff Parking Lot Expansion at Scull Property
DAC Report of October 7, 2020
Page 10
g) Add any protection measures necessary along parking lot edges adjacent to sleep slopes.
h) Confirm number of parking spaces in segment of existing parking south of the Surgery
Center. Restriping may be necessary.
i) Add parking bumpers at the head of parking spaces lacking upright curbing.
j) Show the location of project phase lines.
k) Show location of existing Dumpsters that serve the remaining buildings on property in
each Phase. Construction of Dumpster enclosures or other screening mechanisms may be
required.
12) The Administrative Site Plans will need to show the location of existing utilities (water,
sewer, stormwater, etc.) to remain. This information will be necessary to determine conflicts
with proposed tree planting locations and other site improvements.
13) Construction details for items such as curbing, parking bumpers, traffic control signage, light
fixtures, etc. will need to be provided as part of Administrative Site Plan submissions.
14) The following Landscape Plan information must be clarified for the Master Plan submission:
a) The Development Area must be drawn per the requirement of the Zoning Ordinance. The
Area must compass the frontage to South State Street.
b) Confirm Tree Preservation & Density Worksheet reflects the area and calculation data
correctly. Update the tree planting calculations by identifying the size of the
Development Area then its woodland and non-woodland area. The other areas of existing
woodland to remain can also be listed.
c) Indicate landscaping to comply with the Opaque Barrier components for barrier and
landscaping.
15) The following information must be provided on future submissions as related to Landscape
Plan in accordance with the plan requirements as listed in Zoning Ordinance, Article 5 §16.8:
a) Information and tree planting calculations will need to be made by Phase.
b) Provide list of existing trees to remain and check number of existing trees to be retained.
Trees must be located on the subject parcels to be counted.
c) Add line legend key for Development Area line or label as Development Area (rather
than Landscape Project Area).
d) Ensure tree planting locations and landscaping maintain the required spacing distances or
access provisions from utility lines, fire hydrants, etc.
e) Identify which existing trees will be removed versus preserved by showing placement
location of the tree protection measures. Clarify on a plan drawing like the Existing
Conditions Plan/ Demolition Plan.
f) Clarify what surface (grass, stone or mulch) will be utilized for parking lot islands.
16) Evaluate any existing pavement conditions to remain. Improvements may be necessary to
paving, parking bumpers, and curbing and pavement markings.
17) All signage must comply with Sign Regulations of the Zoning Ordinance and is subject to a
separate Sign Permit Application. Signs are subject to a separate review and approval process
in the City of Dover.
87
Page 88
Item 7.
S-20-10 Bayhealth Staff Parking Lot Expansion at Scull Property
DAC Report of October 7, 2020
Page 11
18) Any Erosion & Sediment Control Plans and Stormwater Management Plans granted approval
by Kent Conservation District must reflect the Master Plan layout and design conditionally
approved by the Planning Commission and be in compliance with the Zoning Ordinance and
technical review requirements of other agencies.
VIII. RECOMMENDATIONS SUGGESTED AS CONDITIONS OF APPROVAL TO MEET
CODE OBJECTIVES:
In accordance with the Zoning Ordinance, Article 10 §2.2, the Planning Commission in
considering and acting upon Site Development Plans may prescribe appropriate conditions and
safeguards so that the public health, safety, and welfare, the comfort and convenience of the
public in general, and the residents of the immediate neighborhood in particular shall be taken
into consideration. These safeguards may to the maximum extent possible further the expressed
intent of the Zoning Ordinance and the accomplishment of several objectives in particular listed
in subsections 2.21 to 2.28.
1) Recommendation on Waiver Requests:
a. Partial Elimination of Curbing – Staff grants approval of the waiver request to relax
upright curbing requirements in select areas related to stormwater management where
sheet flow of water into areas such as swales may be necessary. The locations of such
eliminations of curbing may be refined during the design process for each phase. Parking
bumpers are recommended at the head of all parking spaces where the upright curbing
has been eliminated. This will be further evaluated with the Administrative Site Plan
submissions as greater detail is provided for the stormwater management strategy. This
must be carefully considered related to appropriate quality management due to proximity
to floodplains, wetlands, the Meeting House Branch, and the St. Jones River.
b. Elimination/Relocation of Bicycle Parking – Staff may be able to recommend approval of
this request to relocate bicycle parking upon submission of details on the location and
format of bicycle parking on the main building. However, staff recommends that bicycle
parking continue and/or be made available during Phase 1 construction on the subject site
to serve the existing Surgery Center and Day Care Center buildings.
c. Elimination of Opaque Barrier Component: Staff recommends approval of the waiver to
eliminate the Opaque Barrier Component of the fence, wall, or berm between this non
residential use and the adjacent residential properties to the north. Staff agrees that the
implementation of a fence, wall or berm would be difficult given the topography and
presence of utility infrastructure in the northern area of the site. However, the
landscaping component of the barrier is to be implemented. The existing woodland area
can satisfy a portion of the landscaping requirement and then a design of a hedge or
evergreen trees can be incorporated into the design to screen the remaining areas of the
parking lot. The landscaping does not need to be located directly along the shared
property line but can be planted adjacent to the parking lot area.
2) Vehicular and Pedestrian Connections: In accordance with Zoning Ordinance, Article 10
subsection 2.21 related to safety and convenience of vehicular, transit, bicycle, and
88
Page 89
Item 7.
S-20-10 Bayhealth Staff Parking Lot Expansion at Scull Property
DAC Report of October 7, 2020
Page 12
pedestrian traffic, Staff recommends the following related to vehicular and pedestrian access:
a. Staff recommends an Analysis of the Scull Terrace and South State Street intersection
and pedestrian crossing due to the substantial increase in number of users (both
vehicular and pedestrian) with the implementation of the Phase 1 parking lot
expansion. Improvements to this intersection and pedestrian crossing may be
necessary due to increased volumes.
b. Staff specifically recommends that the Analysis address the impact of increased
volumes of vehicles utilizing the existing (and proposed) entrances, considering shift
patterns and timing, background traffic volumes on South State Street, pedestrian
crossings, adjacent uses, and potential stacking of turning vehicles entering and
exiting the site at each phase of completion.
c. The project should ensure it includes the required accessibility route and ramps from
the parking lot and its handicapped parking over to the main campus. Appropriate
pedestrian connections to other hospital facilities not located on the subject site is a
key element in the consideration of this expanded parking lot to serve multiple
hospital facilities under the provisions of the joint parking facilities.
3) Scenic Resources Consideration: Since the property is listed on the National Register of
Historic Places, consideration of the preservation and or the effects of the development on
the Scull Mansion are required and approaches to mitigation implemented.
a. Staff recommends consideration of options for the adaptive use of the building and
options for the redesign of the parking lot to retain the Scull Mansion building. There
are a variety of Tax Credit Programs for Historic Properties that may be leveraged for
rehabilitation & restoration activities. Other opportunities may include building
relocation and architectural salvage of materials.
b. If demolition of the building is unavoidable, then adequate recordation/documentation
of the Scull Mansion is recommended to gather information on this historic resource.
Documentation of the building would include photographs (exterior and interior),
measured drawings, and information on the building’s construction in accordance
with the Secretary of the Interior Standards and guidelines published by the State
Historic Preservation Office for “Architectural Surveys in Delaware.”
c. Staff recommends requiring mitigation measures such as the development an
informational outreach items such as waysides on the history of the Scull Mansion
property and building.
4) Stormwater Management: The plan provides limited information on the Parking Lot
Expansion Projects’ strategy for stormwater management. There are known drainage issues
in the general vicinity related to the Meeting House Branch (Tar Ditch). This project must
not increase the drainage issues. It is recommended that cooperative participation occur
and/or improvements be made to help resolving drainage issues. The City is involved in
designing and implementing a Meeting House Branch Drainage/Stormwater Management
Improvement Project involving the north area of this property.
5) Landscaping: Staff recommends consideration of installation of shrub/hedge planting along
the South State Street side of western parking lot area as a screening for the vehicles in the
parking lot. Consideration could also be given to utilize changes in site topography as a
screening measure along the western side of the Phase 1 parking lot area. While not required
by Code, this will help mitigate the effects of adding the parking lot to character of the area.
89
Page 90
Item 7.
S-20-10 Bayhealth Staff Parking Lot Expansion at Scull Property
DAC Report of October 7, 2020
Page 13
At the neighboring church property, a landscaped hedge screens the parking lot from the
street.
Other agencies may recommend additional conditions and safeguards in accordance with their
areas of expertise. The Recommended Additional Considerations to Meet Code Objectives may
be accepted or rejected by the Planning Commission.
IX. ADVISORY COMMENTS TO THE APPLICANT:
1) As the property is listed on the National Register of Historic Places (known as Greenwold
and Manlove Hayes House), any projects involving federal funds are subject to the Section
106 process of the National Historic Preservation Act. The applicant has advised that federal
funds are not involved in the project.
2) The Planning Commission should act upon any requests for waivers as part of any motion
regarding this project application, or as a separate motion as necessary. Note: All waivers are
at the discretion of the Planning Commission.
3) If major changes and revisions to the Site Master Plan occur in the finalization of the Plan,
contact the Planning Office. Examples include reconfiguration of parking lots, relocation of
site components like stormwater management areas, and changes in demolition plans. These
changes may require resubmittal for review by the Development Advisory Committee,
Planning Commission, or other agencies and commissions making recommendations in
regard to the plan.
4) Construction will have an effect on the visitors to the site, adjacent property owners and
nearby streets and site access. Any work requiring the closing or rerouting of owners or
visitors shall be minimized and coordinated with the Planning Office and other City Staff as
to offer the least amount of inconvenience.
5) The applicant/developer shall be aware that prior to any ground disturbing activities on the
site the appropriate site inspections and permits are required.
6) Other agencies and departments which participate in the Development Advisory Committee
may provide additional comments related to their areas of expertise and code requirements.
7) The applicant should be aware of the potential for historic archaeological resources which
may include previous building locations, wells, privies, etc. on the property to the rear of the
mansion house. The State Division of Historical & Cultural Affairs can provide technical
assistance when dealing with archaeological resources including previous studies at the
subject properties.
8) Following Planning Commission approval of the Site Development Master Plan, the Plan
must be revised to document all conditions of approval from the Development Advisory
Committee or as otherwise noted. This process involves submission of Check Prints in order
to achieve Final Plan approval; the finalization of the Master Plan and the Site Plan for Phase
1 can be achieved together. Then the Site Plan of each construction phase/project area
(Phases 2-3) must be submitted for Administrative Site Plan Review by the Planning Office
90
Page 91
Item 7.
S-20-10 Bayhealth Staff Parking Lot Expansion at Scull Property
DAC Report of October 7, 2020
Page 14
and other agencies. Zoning Ordinance, Article 10 §2.44 (D) sets forth the construction timing
in relation to approvals.
Article 10 §2.44
(D) Expiration of planning commission approval. For projects which are reviewed and approved
by the planning commission as conceptual master plans, approval of the conceptual master plan
shall remain valid for a period not to exceed five years from the date of planning commission
approval, provided that the authorized construction or use has commenced within two years of
approval and is proceeding toward completion. In addition, the time between the completion of
one phase and the initiation of the next phase shall not exceed a period of two years.
9) The applicant shall be aware that this Master Plan approval does not represent a Building
Permit, Demolition Permit, and associated construction activity permits. An Administrative
Building Permit will be utilized as a tracking mechanism for the site improvements of the
parking lot. Demolition Permits are required to demolish any buildings. A separate
application process is required for issuance of Permits from the City of Dover.
10) The applicant shall be aware that Master Plan approval does not represent a Sign Permit, nor
does it convey permission to place any sign on the premises. Certain types of signage require
a Sign Permit from the City of Dover prior to placement of any such sign; please consult with
Planning Staff in regard to signage.
If you have any questions or need to discuss any of the above comments, please call the
above contact person and the Planning Department as soon as possible.
91
Page 92
Item 7.
CITY OF DOVER ELECTRIC
DEVELOPMENT ADVISORY COMMITTEE
APPLICATION REVIEW COMMENTARY
STAFF D.A.C. MEETING DATE: SEPTEMBER 30, 2020
APPLICATION: Bayhealth Staff Parking Lot Expansion at Scull Property
FILE #: S-20-10
REVIEWING AGENCY: City of Dover Electric Department
CONTACT PERSON: Paul Waddell, Electric Director
CONTACT PHONE #: 302-736-7072
CONTACT PHONE #: pwaddell@dover.de.us
T HE S UBJECT P ROPOSAL HAS BEEN R EVIEWED FOR C ODE C OMPLIANCE , P LAN C ONFORMITY AND C OMPLETENESS IN
A CCORDANCE WITH THIS A GENCY ’ S A UTHORITY AND A REA OF E XPERTISE .
T HE F OLLOWING I TEMS HAVE BEEN I DENTIFIED AS E LEMENTS W HICH N EED TO BE A DDRESSED BY THE A PPLICANT :
CITY AND STATE CODE REQUIREMENTS
ELECTRIC
1. The roadway and curbing must be in.
2. The right-of-way must be within 6" of final grade.
3. The property corners must be staked.
4. Owner is responsible for locating all water, sewer, and storm sewer lines.
5. Owner is responsible for installing all conduits and equipment pads per the City of Dover Engineering Department
specifications.
6. Owner is responsible for site and/or street lighting.
7. Meter locations will be determined by City of Dover Engineering Department.
8. Load sheets and AutoCAD compatible DXF or DWG diskettes of site plans, including driveways, are required prior to
receiving approved electrical construction drawings.
9. Any relocation of existing electrical equipment will be engineered by the City of Dover Electric Department.
Developer may be required to perform a quantity of the relocation. Any work performed by the City of Dover will be
at the owner’s expense.
10. Prior to construction, owner is responsible for granting an easement to the City of Dover Electric Department.
Easement forms will be furnished and prepared by the City of Dover Electric Engineering Department.
11. Fees will be assessed upon final site plans. The owner will be responsible for fees assessed prior to construction.
Owner is required to sign off plans prepared by the Electric Department.
12. Must maintain 10' clearance around all electrical equipment, unless pre-approved by the City of Dover Electric
Engineering Department.
92
Page 93
Item 7.
Bayhealth Staff Parking Lot Expansion at Scull Property
File #: S-20-10
September 30, 2020
Page 2 of 2
13. Prior to the completion of any/all designs and estimates, the owner is responsible for providing the Electric
Engineering Department with a physical address of the property.
14. All Engineering and design for Dover Electric will be engineered upon final approved plans. All Engineering work will
be furnished by the City’s Electric Engineering Department.
RECOMMENDATIONS SUGGESTED AS CONDITIONS OF APPROVAL TO MEET CODE OBJECTIVES
ELECTRIC
1. Owner must give the City of Dover Electric Department three (3) months’ notice prior to construction. Owner is
responsible for following the requirements outlined in the City of Dover’s Electric Service Handbook. The handbook
is now available on the website at the following link:
https://evogov.s3.amazonaws.com/media/27/media/13108.pdf.
ADVISORY COMMENTS TO THE APPLICANT
ELECTRIC
1. Provide load sheets as soon as possible for proper sizing of transformers and creation of primary fee estimates.
Current load sheets can be found at the following link:
https://www.cityofdover.com/media/Electric%20Department/COD%20Electric%20Load%20Sheet.pdf.
I F Y OU H AVE A NY Q UESTIONS OR N EED TO D ISCUSS ANY OF THE A BOVE C OMMENTS , P LEASE C ALL THE A BOVE C ONTACT
P ERSON AND THE P LANNING D EPARTMENT AS S OON AS P OSSIBLE .
93
Page 94
Item 7.
CITY OF DOVER
DEVELOPMENT ADVISORY COMMITTEE
APPLICATION REVIEW COMMENTARY
STAFF D.A.C. MEETING DATE: SEPTEMBER 30, 2020
APPLICATION: Bayhealth Staff Parking Lot Expansion at Scull Property
FILE #: S-20-10
REVIEWING AGENCY: City of Dover Department of Water & Wastewater
CONTACT PERSON: Jason A. Lyon, P.E., Director of Water & Wastewater
CONTACT PHONE #: 302-736-7025
CONTACT PHONE #: jlyon@dover.de.us
T HE S UBJECT P ROPOSAL HAS BEEN R EVIEWED FOR C ODE C OMPLIANCE , P LAN C ONFORMITY AND C OMPLETENESS IN
A CCORDANCE WITH THIS A GENCY ’ S A UTHORITY AND A REA OF E XPERTISE .
T HE F OLLOWING I TEMS HAVE BEEN I DENTIFIED AS E LEMENTS W HICH N EED TO BE A DDRESSED BY THE A PPLICANT :
CITY AND STATE CODE REQUIREMENTS
WATER
1. All water utility components must meet the requirements of the Water Wastewater Handbook, effective date March 22, 2010.
Please contact our office for more information.
2. The following notes must be added to the plans:
a. Hydrant connections by the contractor are prohibited. This method may not be utilized during any phase of the project.
b. Any existing water lines not to be utilized by the proposed facility must be properly abandoned at the mains in accordance
with the City of Dover Department of Water & Wastewater specifications and requirements.
c. The site contractor shall contact the City of Dover Department of Water & Wastewater Construction Manager at (302) 736-
7025 prior to the start of construction. A representative from the City of Dover Department of Water & Wastewater must
observe and approve all City owned water and sanitary sewer interconnections and testing. All water taps must be
performed by a City of Dover approved contractor. The proposed location for the water connection may need to be
adjusted in the field due to conditions of the existing main. Possible conditions that would require tapping relocation
include proximity to pipe joints, other taps, concrete encasements, conflict with other utilities, and the like. Test holes
must be performed by the contractor to determine the best tapping location. The City of Dover will not be held responsible
for field conditions requiring adjustment of the tapping location or for any work required by the contractor to make an
appropriate and lawful connection.
3. Please indicate the water lines that will be abandoned during each phase of the project.
WASTEWATER
1. All wastewater utility components must meet the requirements of the Water Wastewater Handbook, effective date March 22,
2010. Please contact our office for more information.
2. The following notes must be added to the plans:
a. Any existing sanitary sewer lines not to be utilized by the proposed facility must be properly abandoned at the mains in
accordance with the City of Dover Department of Water & Wastewater specifications and requirements.
94
Page 95
Item 7.
Bayhealth Staff Parking Lot Expansion at Scull Property
File #: S-20-10
September 30, 2020
Page 2 of 2
b. Part II, Chapter 180, Article III, Section 180-10 of the Code of Kent County requires that “no person shall discharge or cause
to be discharged any stormwater, surface water, uncontaminated groundwater, roof runoff, subsurface drainage,
uncontaminated noncontact cooling water or unpolluted industrial process waters to any sanitary sewer”, this shall include
condensate. Sec. 110-231 of the City of Dover Code defines storm sewer as “…any system used for conveying rain water,
surface water, condensate, cooling water or similar liquid wastes, exclusive of sewage.” The contractor, developer, owner
and designers shall ensure during construction that no illegal discharges to the sanitary sewer system are created with the
site improvements.
3. Please indicate the wastewater lines that will be abandoned during each phase of the project.
GENERAL
1. All existing utilities shall be adjusted to final grade in accordance with current City of Dover requirements and practices. This
must be included as a note on the plan.
2. Please provide all recorded easements on the plans.
3. No trees may be planted within ten feet (10’) of utility infrastructure.
4. The final site plan must be submitted in the following compatible digital formats:
a. AutoCAD 2018 (.dwg format).
b. Adobe Reader (.pdf format).
RECOMMENDATIONS SUGGESTED AS CONDITIONS OF APPROVAL TO MEET CODE OBJECTIVES
WATER / WASTEWATER / GENERAL
1. None
ADVISORY COMMENTS TO THE APPLICANT
WATER
1. The City of Dover water system is available to this site. The developer is responsible for all costs associated with extending and
providing service to the proposed development.
2. Hydrant flow testing is currently only performed during the spring and fall. The applicant must call the Department of Water &
Wastewater directly to schedule these tests. This applies to both existing hydrants as well as those proposed for the site.
3. Water impact fee credits are eligible for this project, in order to obtain the credits you must contact the Department of Water &
Wastewater prior to the demolition. The credits will be provided for this parcel only.
WASTEWATER
1. The City of Dover sanitary sewer system is available to this site. The developer is responsible for all costs associated with
extending and providing service and capacity to the proposed development.
2. Wastewater impact fee credits are eligible for this project, in order to obtain the credits you must contact the Department of
Water & Wastewater prior to the demolition. The credits will be provided for this parcel only.
GENERAL
1. The applicant is advised that depending upon the size of the existing water service and sanitary sewer lateral to be abandoned,
flowable fill may be required.
2. Construction plans will not be reviewed by our office unless all previous comments have been clearly addressed within the plan
set and accordingly identified within an itemized response letter and with the Water/Wastewater Initial Plan Submission
Checklist, which can be obtained from the following website: https://imageserv9.team-
logic.com/mediaLibrary/198/WaterWastewaterHandbookFinal_1.pdf, page 88.
I F Y OU H AVE A NY Q UESTIONS OR N EED TO D ISCUSS ANY OF THE A BOVE C OMMENTS , P LEASE C ALL THE A BOVE C ONTACT P ERSON AND THE
P LANNING D EPARTMENT AS S OON AS P OSSIBLE .
95
Page 96
Item 7.
CITY OF DOVER
DEVELOPMENT ADVISORY COMMITTEE
APPLICATION REVIEW COMMENTARY
STAFF D.A.C. MEETING DATE: SEPTEMBER 30, 2020
APPLICATION: Bayhealth Staff Parking Lot Expansion at Scull
Property
FILE #: S-20-10
REVIEWING AGENCY: City of Dover Public Works Department
CONTACT PERSON: Sharon J. Duca, P.E.
CONTACT PHONE #: 302-736-7025
T HE S UBJECT P ROPOSAL HAS BEEN R EVIEWED FOR C ODE C OMPLIANCE , P LAN C ONFORMITY AND C OMPLETENESS IN
A CCORDANCE WITH THIS A GENCY ’ S A UTHORITY AND A REA OF E XPERTISE .
T HE F OLLOWING I TEMS HAVE BEEN I DENTIFIED AS E LEMENTS W HICH N EED TO BE A DDRESSED BY THE A PPLICANT :
CITY AND STATE CODE REQUIREMENTS
STORMWATER
1. Final site plan approval will not be granted until a copy of the approved Stormwater/Erosion and Sediment Control
Plan from Kent Conservation District is submitted to our office.
2. The size, length, slope, type and flow directions must be shown on all existing and proposed storm sewer lines. Rim
and invert elevations must be labeled on all stormwater structures. No stormwater management infrastructure or set
aside areas have been shown on the plans which are required.
STREETS
1. Final site plan approval will not be granted until a copy of the entrance plan approval from DelDOT is submitted to our
office.
SANITATION
1. None.
GENERAL
1. One paper copy of the final site plan must be submitted to our office for approval.
RECOMMENDATIONS SUGGESTED AS CONDITIONS OF APPROVAL TO MEET CODE OBJECTIVES
STORMWATER
1. The City of Dover has completed design for a drainage improvement project for the Meetinghouse Branch which has
been reviewed with Bayhealth and various State agencies. The intent of this project is to improve the stormwater
capacity and quality for the area. Part of this project is to convert the existing storm sewer, running from S. State
Street to the adjacent City property, to open channel flow.
a. As part of the proposed lot consolidation plan, easements are to be provided on the plan including, but not limited
to, drainage, utility and construction, to ensure existing utilities and proposed improvements are accommodated.
b. Coordination must occur with our office to ensure that the grading of the parking lot expansion project will be able
to accommodate the Meetinghouse Branch improvement project which will allow for the success of both projects.
Documentation must be submitted to our office for review.
96
Page 97
Bayhealth Staff Parking Lot Expansion at Scull Property Item 7.
File #: S-20-10
September 30, 2020
Page 2 of 2
c. The design for the Meetinghouse Branch improvement project is based upon existing conditions. Design of the
parking lot expansion project must consider the existing and proposed drainage capacity in the area.
Documentation and calculations must be submitted to our office for review.
STREETS
1. None.
SANITATION
1. None.
GENERAL
1. None.
ADVISORY COMMENTS TO THE APPLICANT
STORMWATER
1. None.
STREETS
1. None.
SANITATION
1. City of Dover solid waste collection services will need to be discontinued as part of the proposed plan.
GENERAL
1. Construction plans will not be reviewed by our office unless all previous comments have been clearly addressed
within the plan set and accordingly identified within an itemized response letter.
I F Y OU H AVE A NY Q UESTIONS OR N EED TO D ISCUSS ANY OF THE A BOVE C OMMENTS , P LEASE C ALL THE A BOVE
C ONTACT P ERSON AND THE P LANNING D EPARTMENT AS S OON AS P OSSIBLE .
97
Page 98
C F
S-20-10
Item 7.
I I
T R
CITY OF DOVER Y E
DEVELOPMENT ADVISORY COMMITTEE O M
F A
APPLICATION REVIEW COMMENTARY
R
D.A.C. MEETING DATE: 09/30/20 D S
O H
V A
E L
R
APPLICATION: Bayhealth Staff Parking Lot Expansion at Scull Property
FILE #: S-20-10 REVIEWING AGENCY: City of Dover, Office of the Fire Marshal
CONTACT PERSON: Jason Osika, Fire Marshal PHONE #: (302) 736-4457
THE SUBJECT PROPOSAL HAS BEEN REVIEWED FOR CODE COMPLIANCE, PLAN CONFORMITY, AND
COMPLETENESS IN ACCORDANCE WITH THIS AGENCY’S AUTHORITY AND AREA OF EXPERTISE.
THE FOLLOWING ITEMS HAVE BEEN IDENTIFIED AS ELEMENTS WHICH NEED TO BE ADDRESS BY THE
APPLICANT:
CITY AND STATE CODE REQUIREMENTS:
1. Project to be completed per approved Site Plan.
ADDITIONAL / SPECIFIC REQUIREMENTS TO OBTAIN APPROVAL:
1. Demolition permits required for the existing structures
2. During the phases, the existing buildings egress, perimeter access, and fire lanes need to
remain in place.
APPLICABLE CODES LISTED BELOW (NOT LIMITED TO):
2015 NFPA 1 Fire Code (NFPA; National Fire Protection Association)
2015 NFPA 101 Life Safety Code (NFPA; National Fire Protection Association)
2013 NFPA 72 National Fire Alarm and Signaling Code (NFPA; National Fire Protection Association)
2013 NFPA 13 Installation of Sprinkler Systems (NFPA; National Fire Protection Association)
2009 IBC (International Building Code)
Latest editions of all other NFPA Codes as defined by the Delaware State Fire Prevention Regulations
2015 Delaware State Fire Prevention Regulations
City of Dover Code of Ordinances
*If you have any questions or need to discuss any of the above comments, please call the above
contact person listed.
98
Page 99
Item 7.
CITY OF DOVER D
E
DEVELOPMENT ADVISORY COMMITTEE
L
APPLICATION REVIEW COMMENTARY D
O
T
===============================================================
APPLICATION: Bayhealth
FILE#: S-20-10 REVIEWING AGENCY: DelDOT
CONTACT PERSON: Joshua Schwartz PHONE#: 302-760-2768
===============================================================
THE SUBJECT PROPOSAL HAS BEEN REVIEWED FOR CODE COMPLIANCE, PLAN CONFORMITY AND COMPLETENESS IN
ACCORDANCE WITH THIS AGENCY'S AUTHORITY AND AREA OF EXPERTISE.
THE FOLLOWING ITEMS HAVE BEEN IDENTIFIED AS ELEMENTS WHICH NEED TO BE ADDRESSED BY THE APPLICANT:
CITY & STATE CODE REQUIREMENTS:
No person, firm, corporation or the like shall construct, open, reconstruct, maintain, modify or use any
crossing or entrance onto a state-maintained highway, street or road, including any drainage modifications
leading into or carried by the highway drainage system, without first having complied with standards and
regulations adopted by the Department and having obtained a permit issued by the Department.
Please contact the Delaware Department of Transportation - Development Coordination section to begin
permit process.
RECOMMENDATIONS SUGGESTED AS CONDITIONS OF APPROVAL TO MEET CODE
OBJECTIVES:
ADVISORY COMMENTS TO THE APPLICANT:
1. The developer shall schedule a meeting to discuss the plan. DelDOT previously approved a parking
plan on July 24, 2014, However, it appears this plan is different.
99
Page 100
Item 7.
PARKING LOT EXPANSION NECESSITY
The Bayhealth Kent Campus staff is in desperate need of additional parking.
The current number of employees for Bayhealth exceeds 2,000; however, that number
is increasing. The parking facilities of the hospital must be able to accommodate the
shifts that require nearly 700 employees. Not only is the Bayhealth staff increasing,
but the community that Bayhealth serves is growing as well, so parking is a key need
for the facility.
Bayhealth currently has a master plan to expand its parking facilities at the
South Street location, which includes a parking garage. However, there is an existing
flooding issue in the area that encompasses this lot. The City of Dover informed
Bayhealth that the City will be fixing the drainage issue, and that design is underway.
But until the flooding issue can be properly fixed, parking is still an issue. The
flooding in this area has caused significant damage to property, vehicles, and created
issues for the hospital.
The proposed parking lot would free up space at the South Street lot for
patients and visitors, while Bayhealth Staff park at the Scull Mansion lot. The South
Street lot is close to the hospital entrance and is safely accessed by crossing South
Street.
As the need for outpatient procedures has increased, the demand for safe and
accessible parking has also increased. The proposed parking lot expansion at Scull
Mansion would allow for patients and visitors to use the parking lot at South Street
while the Bayhealth staff would utilize in the Scull Mansion lot. Access to the
hospital from the Scull Mansion lot is provided via the lighted pedestrian crossing
that runs across State Street. Bayhealth staff will be trained to safely use this crossing.
Keeping patients and visitors in the South Street lot prevents untrained individuals
from attempting to use this crosswalk. This provides a much safer environment for
both pedestrian and vehicular traffic on State Street.
The lack of parking for Bayhealth facilities has been a long-standing issue. It
has created unnecessary congestion for the public as well as Bayhealth staff and
patients. This parking lot expansion not only benefits Bayhealth staff, it benefits
every patient that seeks care at this facility. Parking can be safely provided for
Bayhealth staff at the proposed facility while their patient base can safely access the
hospital from the South Street lot. This eliminates the need for staff to park on the
street and relieves congestion in this area.
100
Page 101
Item 7.
SCENIC, HISTORICAL, AND ENVIRONMENTAL PRESERVATION
Bayhealth Kent Campus Hospital is an integral part of the City of Dover
community. Not only is Bayhealth the largest employer in the city, the hospital also
provides a wide variety of services to the public. The proposed parking lot is an
essential addition for Bayhealth, providing staff with parking for a shift.
The proposed parking lot is located on the east side of State Street at Scull
Terrace; properties owned by Bayhealth. This property is adjacent to the Jones River,
contains woodlands and wetlands, and Scull Mansion. Bayhealth proposes to preserve
the existing woodlands and wetlands that are on site. In addition, the improvements in
this area are kept away from the Jones River, so as not to disturb the aquatic
environment. The owner would also like to preserve Scull Mansion in a unique and
memorable way.
This project would require the demolition of Scull Mansion, a building listed
on the National Register of Historic Places; however, is not in the City of Dover
Historic District. Still, the project does not intend to demolish the history of Scull
Mansion, a building which is now used as office space.
Bayhealth would like to preserve the memory and history of the building in
the form of a memorial which would be located in the parking lot itself, as well as in
the hospital. This memorial would preserve the history of Scull Mansion through
pictures, a written history, and artifacts from the building. The memorial would show
the public everything about Scull Mansion in a timeless preservation located within
the parking lot.
In addition, another commemorative building component will be located
within the hospital itself as a work of historical preservation. This would contain
artifacts from Scull Mansion, a history of the building and owners, and specify the
location of where the building once stood. The memory of Scull Mansion, as well as
pieces from the building, will be preserved and displayed within the hospital for the
community benefit.
101
Page 102
Item 7.
WAIVER REQUEST
OPAQUE BARRIER AND LANDSCAPING REQUIREMENT
KGH DEVELOPMENT CORP.
PARKING LOT EXPANSION FOR BAYHEALTH STAFF
2019184.07
REQUEST: Elimination of constructing opaque barrier and landscaping
on a non-residential use when abutting a residential use.
EXTENT OF THE REQUEST: The City of Dover Zoning Code, Article 5, Section 7.2
requires visual and sound screening be provided on a non-
residential use when abutting a residential use. Screening
shall consist of an opaque barrier at least six feet in height,
accompanied by landscaping. The planning commission
may waive this requirement for the opaque barrier in cases
where noise is not a concern and the vegetation alone is
considered a desirable aesthetic alternative. A waiver is
requested to eliminate the construction of the opaque
barrier and landscaping on the northern portion of the site.
BASIS FOR REQUEST: The basis for this request is the existing area that
significantly separates the site improvements from the
adjacent residential zone. The site is not in the vicinity of
the residential properties; there is a significant distance,
ranging from 75’ – 400’, that separates the parking lot
improvements from the residential properties. In addition,
there is an existing ravine which is as tall as 17’ that
significantly separates the parking lot from the residences
both visually and from noise. Furthermore, the substantial
separation area has an existing, dense tree line that is much
taller than the 6’ minimum tree requirement of the City.
The owner would like to preserve this wooded area as
much as possible.
Not only is the existing area densely wooded with a raised
earthen ravine; the area is used extensively for utilities as
well as by the City of Dover. There are existing overhead
electric, major city storm drain, and major city sewer
located in the area that run to the City of Dover Treatment
201918407am-Waiver-Opaque Barrier and Landscaping
102
Page 103
Item 7.
Plant. Erecting a fence would compromise the existing
utilities and cause significant hinderance to access of the
area.
Additionally, this area is prone to flooding from State
Street and the surrounding area. There is an existing ravine
that causes stormwater runoff to flow from the residences
into the separation area. There is another existing ravine
that allows stormwater to flow from the parking lot area
into the separation area. Both ravines flow directly into the
low-lying area that separates the parking lot improvements
and the residences. Erecting a fence on either side of this
separation area would impede floodwater flow, causing
additional flooding of the residential properties and parking
lot area. Disturbing the area for fencing and landscaping
would not only impede floodwaters, but could cause scour
erosion which would impact the city’s existing
infrastructure. For the reasons listed above, Becker Morgan
Group is requesting a full waiver from Article 5, Section
7.2 of the City of Dover Zoning Code.
201918407am-Waiver-Opaque Barrier and Landscaping
103
Page 106
Item 7.
MAIN
OUTPATIENT
ENTRANCE
REHAB
DISCHARGE
ED
ENTRANCE
OUTPATIENT
PHYSICIAN
ENTRANCE BAYHEALTH BIKE RACKS PARKING
106
Page 107
Item 7.
S-20-10 Bayhealth Staff Parking Lot Expansion at Scull
Property
EXHIBIT SET 1 – Public Comments Received
Public Comments (received to date 10/9/2020)
1. Letter from Friends of Old Dover (Dover Historical Society)
received 10/5/2020
2. Email from Nathan Attard on 10/9/2020 with attached copy of
Letter sent to Terence Murphy, CEO Bayhealth. Letter includes
with listing of Petitioners in support of Letter.
107
Page 109
Item 7.
From: Arnold, Nichole M
To: Melson-Williams, Dawn
Subject: FW: Letter regarding Bayhealth"s proposed demolition of the Scull Mansion
Date: Friday, October 09, 2020 9:44:42 AM
Attachments: Scull_Mansion_Letter.pdf
Is this for you?
From: Nathan Attard <nateattard@gmail.com>
Sent: Friday, October 9, 2020 6:36 AM
To: danielle_pro-hudson@bayhealth.org; pam_marecki@bayhealth.org
Cc: Permits & Licenses <permitsandlicenses@dover.de.us>
Subject: Letter regarding Bayhealth's proposed demolition of the Scull Mansion
Ms Pro-Hudson and Ms. Marecki,
My name is Nate Attard, I organized an online petition campaign asking Bayhealth to reconsider its
decision to demolish the Scull Mansion. Attached is the letter that resulted from the campaign so
far, which started on Sunday 10/04 and will continue until a final decision is made by the City. We
have more than 100 signatories, including 27 Dover residents.
I apologize for having to direct this letter to you, however the email of the CEO is not listed on the
Bayhealth website. If you could kindly direct it to him, I would appreciate it. I can be contacted at
this email and at the phone number below.
Thank you,
Nate Attard
--
Nathan Attard
nateattard@gmail.com
716.868.6594 (m)
109
Page 110
Item 7.
Terence Murphy
CEO, Bayhealth
640 South State Street
Dover, Delaware 19901
Dear Mr. Murphy,
We the undersigned are aware of an upcoming meeting of the City of Dover Planning Commission on
October 19, 2020. At this meeting, Bayhealth is seeking site plan approval for a proposal that will result
in the demolition of a number of buildings, including the historic Scull Mansion, listed as Greenwold on
the National Register of Historic Places. These buildings would be replaced by more than 450 parking
spaces per a City of Dover agenda.
Greenwold was constructed in 1863 by Manlove Hayes, a Kent County farmer, steamship line owner,
clerk of the Delaware Senate and State Representative, who is credited with designing the house
himself. The house is one of Dover's surviving Italianate stucco buildings, relatively rare in Dover due to
the community's interest in the Colonial Revival style in the early to mid-20th Century, which would
have seen many of these houses redesigned.
Popularly referred to in Dover as the Scull Mansion, the house's listing on the Register was due to the
initiative of Sarah Scull, occupant of the house until 1986, the widow of Dr. Carl Scull, who preceded her
in death in 1950. Dr. and Mrs. Scull are buried in nearby Christ Church Cemetery.
We appreciate Bayhealth's stewardship of this property until the year 2020. Bayhealth has found
numerous acceptable uses for this house since it took ownership, and ideally these would continue. We
ask that you continue in this stewardship role of this piece of Dover's history, or allow others the
opportunity to do so through sale of the historic house, with requisite protection, such as a preservation
easement, that will allow for its restoration.
We are aware that the City of Dover has created no form of legal protection for this property or any
properties outside its designated historic district, and technically this can take place without review by
the Historic District Commission. We implore you as our community's hospital to please consider the
good of the community in this action. Once lost, this piece of history cannot be replaced. Its removal will
forever change the landscape of South State Street and erase the memories above that belong to it.
Thank you.
Nathan Attard, Dover (Petition Organizer) Mary Kathleen Bason, Dover
Alex Griffin, Dover Elisabeth Vassas, Dover
Kate Crossan, Dover Ruth Ann Piper, Dover
Ellen Richardson, Dover* Sally Verma, Dover
Teresa Pierce, Dover Robert Clemens, Dover
Kathleen Spicer, Dover Kaitlyn Rose Staub, Dover
Nathan Walston, Dover Theresa Staub, Dover
Linda B. Capone, Dover James M. Staub, Dover
110
Page 111
Item 7.
Laura Bell-Burkett, Dover Jenny Mola, Frederica, DE
Craig Burkett, Dover Lorraine J. Dion, Frederica, DE
Cheri Knies, Dover Sarah Hohman, Georgetown, DE
Anneke Cerri, Dover Lisa Maglione, Greenwood, DE
Jeff Cerri, Dover Patty Murray, Hartly, De
Patrick Weaver, Dover Nancy L Crowder, Historic New Castle, DE
Erika Martine-Duquette Dover Susan Washinski, Houston, DE
Jodie Wedel, Dover Jane Dean, Lincoln DE
Adam Cerri, Dover Bruce Knotts, Magnolia, DE
Gerald & Diane Strert, Dover Donna W. Josefowski, Magnolia, DE
Jean Northwood, Dover William Lindewirth, Magnolia, DE
The Hurst Family, Dover Heather Truitt, Magnolia, DE
Cynthia Witt (Mrs. Charles L. Witt), Dover Carl Roosa, Magnolia. DE
Hilary Welliver, Dover Yvonne Steele, Marydel , DE
Brad Richardson, Dover Susan Kemer, Middletown, DE
John Pancoast, Dover Ben Haigh, Middletown, DE
Sen. Trey Paradee, Dover Sharlym N Ives, Middletown, DE
Barbara Sheperson, Dover Stacy Calvert, Middletown, DE
Bethany Geleskie, Dover Danny Jenkins, Middletown, DE
Stephanie Twilley Seeman, Dover Jeff Kokoszka, Middletown, DE
Georgeanna Windley, Dover Rosemary Connelly, Milford, DE
Tim Shepperson, Dover Justin Stumpf, Newark, DE
Tyler Capanna, Bear, DE Elle Sheaffer, Newark, DE
Lois Hutson, Bellingham, WA (former Delaware Sharon Mitchell, Newark, DE
resident) Nancy Willing, Newark, DE
Bryan Hudson, Camden, DE Sherri Clark, Newark, DE
Charles P. Ritchie, Camden, DE Jeff Pincin, Newark, DE
John Riggins, Camden, DE Anne Groo, Newark, DE
Susan Rigby, Camden, DE Ernie Mabrey, Philadelphia, PA
Ann Martini, Camden, DE Janet Converse, Raymond, OH
Crystal Beenick, Camden-Wyoming, DE Wendy Miller, Richfield Springs
Georgia Kimball, Camden Wyoming, DE Dee Durham, Rockland, DE
Ruth Anne Clarke, Chesapeake City, MD Jared Pibkerton, Seaford, DE
Si Osborne, Chicago, IL** Cheryl Thaler, Seaford, DE
Elaine Morris, Clayton, DE Gere Durkin, Smyrna, DE
Daniel Mifflin Wilson, Cleveland, OH*** Caitlin Wright, Smyrna, DE
Lynn Dilliplane, Delaware City, DE D Sue Hensley, Smyrna, DE
John Martin, Delaware City, DE Leora Briggs Hansa, Smyrna, DE
D Hansen, (not listed) Ashley Pelletier Smyrna, DE
Alicia Gibson, Elkton, MD Kristina Coldiron, Townsend, DE
Tina Husfelt, Ellendale, DE Steven Hubschmitt, Wilmington, DE
Donald Adriance, Felton, DE Nancy Graybeal, Wilmington, DE
Carol T, Felton, DE Sandra Messick, Wilmington, DE
Michael Smith, Felton DE Steve Hubschmitt, Wilmington, DE
111
Page 112
Item 7.
Sarah Luca, Wilmington, DE Joyce Schurter, Wyoming, DE
Carolyn Roland, Wilmington, DE Liza Giaccone, Wyoming, DE
Michelle Jones, Wilmington, DE Jessica Besecker, Wyoming, DE
Sarah Ottinger, Wyoming, DE Liz Dunn, (not listed)
Notes provided to the petition organizer:
*Ms. Richardson is the daughter-in-law of Becky Scull Richardson, who was the daughter of Dr. and Mrs.
Scuill
**Mr. Osborne is the grandson of Sarah Scull
***Mr. Wilson wrote “It was the home of my great great grandfather, Manlove Hayes. He lived there
until his death in 1910, his daughter Anna Bell Hayes lived at Greenwald until she died in 1946. I lived
there when I was born in 1943. Our family sold the Manlove Hayes house to Dr Scull in 1946, the heirs,
Manlove Hayes Wilson, Ralph C Wilson, & Richard E Wilson (also known as grandsons of Manlove
Hayes). We would hope City of Dover would preserve, as aside, where City Hall is now, where the Library
is located, are both on the lands of Manlove Hayes.
cc: City of Dover Planning Commission
112
Page 113
Item 7.
S-20-10 Bayhealth Staff Parking Lot Expansion at Scull
Property
EXHIBIT SET 2 – Public Comments Received
Public Comments (received to date 10/19/2020 at 3:00pm)
1. Letter from Mayor Robin R. Christiansen dated October 15, 2020:
Letter of Support to Planning Commission
2. Email from Karen Horton on 10/18/2020
• Previously EXHIBIT SET 1 – Public Comments Received thru
10/9/2020 was distributed as part of Planning Commission
Meeting Packet.
113
Page 114
Item 7.
City of Dover
OFFICE OF THE MAYOR
October 15, 2020
Attention: Commissioners and City of Dover Planning Commission
RE: Letter of Support to Planning Commission
First of all, please let me express to you my deepest gratitude for your service to our City as
Commissioners of the Planning Commission, particularly during this pandemic. Because of your
efforts and those of the Planning Staff, the City continues to grow. Once again thank you.
Having said that I am writing to you in support of Bayhealth and their proposed plan for
expanded parking for staff and visitors alike. I must tell you that I have grave concerns about the
demise of the Scull Mansion property. It is my sincere hope that a compromise may save this
historic building and its charm. It is my sincere hope that some accommodation to preserve this
elegant home can be formed.
As Mayor of the City of Dover, I am charged with economic development which includes
protection of existing jobs, revenues, the support of the expansion and retention of major entities,
and the recruitment of new facilities of jobs. This plan does both and therefore I highly support
the proposed project as presented. It is a map for future expansion of the workforce of Bayhealth
and other jobs that will be generated in the public and retail sector.
Also, the advent of this proposal will remove many of the current parking and transportation
concerns, as well as, drainage issues in the area.
Thank you for your consideration of this proposal.
Respectfully yours,
Robin R. Christiansen
Mayor
City of Dover
P.O. Box 475, Dover, DE 19903-0475
Community Excellence Through Quality Service 114
Page 115
Item 7.
From: Karen Horton
To: CompPlan
Subject: S-20-10 Bayhealth Staff Parking Lot Expansion at Scull Property
Date: Sunday, October 18, 2020 8:44:19 PM
Dear Planning Commission Members,
My name is Karen Horton and I was born and raised right here in Dover. I am very much against the demolition of
the Skull Mansion or the brick building just north of it. As a child growing up here, I remember trying to memorize
all of the details of this beautiful mansion because it was such an elegant and graceful building - it made such an
impression. Given the history of Skull mansion, how these two buildings contribute to what makes Dover special,
and in particular how these two buildings contribute to how one enters downtown Dover coming from the south,
there has to be another way than demolishing these buildings.
There are communities across America wondering how they can create such a beautiful gateway to their downtown
areas. Here we have such a stunning gateway with these two buildings and Bayhealth is even thinking of paving it?
Please do not let this happen. Bayhealth has already torn down enough buildings, paved enough parking, and built
a massive parking garage. I don’t care what kind of landscaping plan they have, this will alter Dover in a manner
that cannot be fixed. This area of Dover cannot take anymore parking…. With all the craziness in the world, I
cannot help but believe this is trying to be slipped through. I truly implore the Dover Planning Commission, and
City leadership to come up with an alternative solution.
Thank you for your consideration.
Karen Horton
Dover, DE 19904
115
Page 116
Item 7.
S-20-10 Bayhealth Staff Parking Lot Expansion at Scull
Property
EXHIBIT SET 3 – Correspondence Received
Correspondence (received to date 4/9/2021)
1. Letter from Friends of Old Dover (Historical Society of Dover) to
John Van Gorp, Bayhealth Medical Center dated January 5, 2021;
Letter was copied to David Hugg, Director of Planning and
Inspections
2. Letter from Friends of Old Dover to Bayhealth Board of Directors,
Facilities Committee (Attn: John Van Gorp) dated March 19, 2021;
Letter was copied to Planning Staff for the Planning Commission
• Previously EXHIBIT SET 1 – Public Comments Received thru
10/9/2020 was distributed as part of Planning Commission
Meeting Packet.
• Previously EXHIBIT SET 2 – Public Comments Received thru
10/19/2020 at 3:00pm was distributed to the Planning Commission
by email.
116
Page 117
Item 7.
March 25, 2021
David S. Hugg III
City Planner
City of Dover Planning & Inspections
P.O. Box 475
Dover, DE 19903-0475
RE: Bayhealth Medical Center
BAYHEALTH KENT CAMPUS / SCULL PROPERTY
SITE DEVELOPMENT
Dover, Delaware
2019184.07
Dear Dave:
I am writing as a follow-up to our telephone conversation this week concerning
reactivating the review process for the above-referenced site plan on behalf of
Bayhealth Medical Center. We are formally requesting the project be removed from
the “table” and be scheduled for the April 19th, 2021 Planning Commission hearing.
Since we requested to be tabled last year, Bayhealth has held a series of meetings
with both neighbors and stakeholders. Specifically, we have had meetings with
neighbors on Elm Terrace, Holy Cross Church, and a series of three (3) meetings with
the Friends of Old Dover. We have listened to the various groups and have modified
our plans to account for the feedback. Specifically, we are offering the following
revisions:
1. We have removed the demolition of the Scull Mansion from Phase I of our
project. The attached plan shows the modification to the parking area
eliminating thirty-nine (39) total parking spaces to accommodate the building
allowing it to remain.
2. We are willing to donate the building to the Friends of Old Dover to allow
them to renovate, utilize, and relocate the structure. We will assist them in
relocation of the structure and are willing to donate funds to them to facilitate
a move.
3. We agree to keep the structure on site for a period of eighteen (18) months
from the April hearing allowing the Friends of Old Dover time to raise money
and organize a move of this structure, or otherwise develop a resolution
acceptable to Bayhealth. If after the 18 months the structure has not been
relocated or otherwise resolved, we reserve the right to seek demolition.
4. We will develop a landscape plan for the stie that exceeds the city code
requirements and enhances the visual impact on the hospital and State Street.
We have heard comments concerning the need to adequately screen the
117
Page 118
Item 7.
parking lot and we want the area to be a visually appealing. We will present a
graphic of the plan at the Planning Commission meeting.
5. Our final phases of the master plan will be the demolition of the outpatient
surgery center and the childcare facility located on the eastern side of the
property. Bayhealth will not be removing those two (2) functions from
operation and will relocate each likely on the main campus. We currently
believe that relocation will be at least five (5) years away and could be longer.
We look forward to appearing before the City of Dover Planning Commission in
April. We will make a presentation to them outlining the various public outreach we
have done and the changes to the plan.
Sincerely,
BECKER MORGAN GROUP, INC.
Gregory V. Moore, P.E.
Vice President
GVM/rlh
201918407aq-ltr-DHugg.docx
118
Page 119
24x36 24x36
Item 7.
UE X LEGEND
24x36
FP 24x36
12
ITEM EXISTING PROPOSED
X
SANITARY GRAVITY SEWER LINE, EX. 10"S 10" S
FP SIZE & FLOW DIRECTION
FP
24x36
X 24x36
SANITARY SEWER FORCE MAIN, SIZE EX. 10" F.M. 12" F.M.
12 LANDS N/F FP & FLOW DIRECTION FP
18 U.T. RICHARD J. KOSIOR
U.T. & KATHLEEN P. KOSIOR FP X
SANITARY SEWER MANHOLE (S.M.H.)
T.P.: 2-05-07709-05-7100-00001
DEED REF.: 5045-0067 P LANDS N/F
24x36 LANDS N/F F MICHAEL GRANT SANITARY SEWER CLEANOUT 24x36
MATHEW PERZA ZONING - R8 X
EX. 15"S 12 & RACHEL GRANT
T.P.: 2-05-07709-05-7101-00001 FP FP WATER MAIN & SIZE EX. 10" W 12" W
DEED REF.: 8452-0199 T.P.: 2-05-07709-05-6500-00001
RCP EX. 48" DEED REF.: 9012-0298 FP
ZONING - R8 F.H. F.H.
ARCH I T E C TURE
ZONING - R8 FIRE HYDRANT
EX. 6"W
X
24x36 24x36
EX. 15"S LANDS N/F WATER VALVE (W.V.) OR METER (W.M.)
N 78° 25' 47 FP
DENNIS J. GRIMM
T.P.: 2-05-07709-05-6400-00001 FP X
W.M. W.V. W.M. W.V. ENG I NE E R I NG
FCM " EEX. 48" RC DEED REF.: 5079-0078 LANDS N/F STORM DRAIN MANHOLE (S.D.M.H.)
PFIP
N 16° 12'
Dover, DE
10" W 75.44'
ZONING - R8 KATHLEEN M. UNTERKOFLER FP
U.T.
12
24x36
EX. 15"S T.P.: 2-05-07709-05-6300-00001 STORM DRAIN LINE (CMP OR RCP)
X
24x36
FP
FP
DEED REF.: IS-0026-0405 LANDS N/F
LISA MARIE ROSSI
309 S. Governors Ave.
ZONING - R8
FP T.P.: 2-05-07709-05-6200-00001 CATCH BASIN Dover, DE 19904
343.96'
EX. 12"S
X FP
FIR
FP
DEED REF.: 7048-0014
ZONING - R8
Ph. 302.734.7950
FP UTILITY POLE W/ OVERHEAD SERVICE
24x36
S (TELEPHONE X
X OR ELECTRIC OR BOTH) FP Fax 302.734.7965 24x36
18 17 68 FP V V V X X X
U.T.
16 10' SIDE YARD SETBACK LINE °0 EX. 15 FP X
48.98'
15 FP X X UNDERGROUND ELECTRIC U.E. U.E. Salisbury, MD
26.45'
14 "S
FH 18
X FP
EX 6' FP
V V
FP X X X FP
. 4 33 FP
FP UNDERGROUND TELEPHONE U.T. U.T. 312 West Main St. Suite 300
24x36
8" "E FP FP 24x36
FP RC FP Salisbury, MD 21801
SCM .
W.V
12 P V FP V FP EX. 15"S
X UNDERGROUND GAS MAIN EX. 2" G 2" G
OE
FIR FP FP
N/A
Ph. 410.546.9100
OE OE PAVEMENT TO BE REMOVED
188 OE OE X Fax 410.546.5824
1 OE OE
24x36
112 OE OE OE OE OE OE
CONCRETE CURB & GUTTER 24x36
2 V OE OE OE OE OE Wilmington, NC
LANDS N/F OE OE
CONCRETE SIDEWALK, SLAB / PAVING
13 FP MOLLY B. PHILLIPS X
FP
. EX. 8"S APPROXIMATE LOCATION T.P.: 2-05-07709-05-6100-00001 FP 3333 Jaeckle Drive, Suite 120
W.V 11 V 12 IMPERVIOUS SURFACED ROAD, DRIVE
W.V W
24" 24" 30" 14 12 OF 100 YEAR FLOOD PLAIN 7.
DEED REF.: 7372-0173
ZONING - R8 LANDS N/F OR LOT FP Wilmington, North Carolina 28403
24x36
EX. 8"W
.
13 16 X FP
24x36
.V. W.V 15
24"
14 FP '
DONALD L. HENRY Ph. 910.341.7600
T.P.: 2-05-07709-05-6000-00001 INDIVIDUAL TREE OR BUSH N/A
UT . UT 15 FP V DEED REF.: 5775-0149 EVERGREEN DECIDUOUS Fax 910.341.7506
16 36" 16 N 87 ZONING - R8 LANDS N/F X WIRE FENCE X X X X X X
V
° 59' GIA DOWNTOWN FP www.beckermorgan.com
FP 32" E FP
17 18 19
V PROPERTIES, LLC CHAINLINK FENCE
24x36
19 17 24x36
96" FP T.P.: 2-05-07709-05-5901-00001 X STOCKADE FENCE
DEED REF.: 8444-0331
OE 18
FP
V ZONING - R8
5 19 FP V FP STRUCTURE (CONCRETE, WOOD,
FP 152. METAL, ETC.)
24x36
U.T. 09' X FP
24x36
EX. 12"S
U.T.
FP V N 77° 42' 04"
20 20 E DRAINAGE DITCH OR SWALE
V
V 50.03' EMBANKMENT SIDESLOPES (DOWN)
RADIUS: 1462.69' 21
24x36
ARC LENGTH: 284.55' V S 15° 02' 25" E X 24x36
V FP CONTOUR 49 55
CHORD BEARING: N 10° 37' 47" W 48" 21 V 7.58' FP
22 FP Xref-Phase-1-Parking-Blk 43.55 25.50 T.C.
.90'
V ELEVATION SPOT SHOT
CHORD LENGTH: 284.10' 25.15
108 47" W
20 25.00 B.C.
23 BENCH MARK
34'
X N/A
18' 18' 24' 18' 52°
24x36 24x36
22 PROPERTY OR RIGHT-OF-WAY LINE
48" 24" S
10 AC
23 X FP CENTERLINE
FP
24 FP
24 5 ' LIGHT POLE FP
74.9
24x36
25 X
24x36
18 9 CONSTRUCTION NOTE N/A
.85'
EX. 18"S
26
48" 15' REAR YARD FP
183
10 1
21 X FP
25 TWO STORY 27 1 2 SETBACK LINE FP
S 15° 02' 25" E
24x36
1 FP 24x36
BRICK
BUILDING 13 4 FP X
2,743 SQ. FT. 1 5 LANDS N/F
1 6
RADIUS: 1462.69' 1 CITY OF DOVER X
22 T.P.: 2-05-07713-01-5700-00001
24x36
ARC LENGTH: 462.51' 10 17 8 DEED REF.: 5011-0121
24x36
CHORD BEARING: N 7° 08' 39" W 1 9 FP
26 1
ZONING - IO
CHORD LENGTH: 460.59' 48" FP X
20 1
FP
PROPOSED 2 2
24x36
"S
AC
2 APPROXIMATE LOCATION X LANDS N/F
24x36
70.00'
CONCRETE CURB (typ.) 23
.
OF 100 YEAR FLOOD PLAIN CITY OF DOVER
EX. 12 23 60"
ONE STORY 24
25 T.P.: 2-05-07713-01-5000-00001
27 FRAME
BUILDING
26
27
N 74° 57' 34" E FP
X DEED REF.: T-0036-0203
ZONING - IO N
24x36
28 1,112 SQ. FT. 170.01' FP 24x36
71.52'
S 15° 02' 25" E
10 34 98.49'
V
X
28
24x36
24 10 FP
V X 24x36
V FP
24"
28 FP V X
PHASE 1 PARKING ADDITION PROPOSED PARKING PROPERTY LINE TO BE
29 LIGHT FIXTURE (typ.) EXTINGUISHED PER THE
24x36
139,815 S.F. / 15,535 S.Y. V
FP 24x36
FP V
25 29 CONSOLIDATION PLAN X
60"
25 30"
9'
26 18' FP X
20' FRONT YARD
80.00'
27 30'
36OE 21
24x36 24x36
30 9
SETBACK LINE 30" OE OE X X X OE 10 X
PROJECT TITLE
36"
28
24"
18' 265
11
24x36
RADIUS: 1462.69'
ARC LENGTH: 177.96'
3 0"
29
31
31 ONE STORY
POLE
BUILDING
2 4
2
245
12
13
14
15
S8 X 7° 2
9' 2
X
2" E
BAYHEALTH 24x36
26
CHORD BEARING: N 1° 34' 16" W 24'
255
294 1,440 SQ. FT.
197 26
2 16 N 73° 01' 53" E
17
X
X 78.4 MEDICAL
TE
CHORD LENGTH: 177.86' 18
28.34' 8' X
24x36
30"
40' 10 30
15 19
20
21
S
74
X
°5
CENTER, INC 24x36
STR
W.V
. 18' 22
0' X
23 58
.
W.M 31 38 34 24'
. 6"
S
" X
E
SCULL PROPERTY
24x36
EX 24x36
18'
24 SITE DEVELOPMENT
EET
X
TWO STORY 26
KCR OT W
20 X
FRAME BUILDING
1,044 SQ. FT.
25 EX. 6"S
X FP
MASTER PLAN
24x36
PROPOSED PROPOSED 24 3 24x36
24' 2 25 X FP
BAYHEALTH STAFF
25, IDE R
32 CONCRETE CURB (typ.) EX. 6"S CONCRETE CURB (typ.) 23 4
30 29 2 X
24'
32
31
28 X PARKING LOT
STA
25 FP FP
9' 27
MIN IG
24x36
27
18'
12" STEEL - MD - 7.13'
26 X EXPANSION 24x36
OR HT O
4" PVC - MD - 2.01'
EX. 30" F.M.
26 FP
26 42 34 X 18
26 8" PVC - MD - 5.84' 8" PVC - MD - 5.55'
3.8 605 S. STATE STREET
X 8' FP
18'
ART F W
24x36
4" PVC - MD - 1.66'
4" PVC - MD - 1.70'
4" PVC - MD - 2.34'
8" PVC - MD - 3.84'
X
FP CITY OF DOVER 24x36
8" PVC - MD - 3.53'
KENT COUNTY, DELAWARE
SOU
30" 28 9 33 FP
ERI A
FP
AL Y
X
TWO STORY SHEET TITLE
2"S
PROPOSED PARKING 24'
PORCH S 34
STUCCO BUILDING
TH
24x36
EX. 34 24x36
LIGHT FIXTURE (typ.) 2,100 SQ. FT. G.M.
1
60
X
° 35
SITE PLAN
FO 17 26 FP X
PHASE 1
EX. 18"S ' 27"
24x36 24x36
.P. EXISTING ONE-STORY
R.C
24"
.88' 21 44 33 32 COVERED
ENTRANCE BRICK BUILDING E X
31 OUTPATIENT SURGERY CENTER
24x36
EX.
184
30 17 10,800 S.F. ± - FOOTPRINT
26
FP X TOTAL PARKING 24x36
15' REAR YARD
PROPOSED
27"
29
28 PHASE 1 EXISTING PARKING
27 26 SETBACK LINE X SPACES: 478
24x36
ACCESSIBLE RAMP (typ.) TO BE REPAVED GEN
24x36
28 14 ACCESSIBLE PARKING SPACES (2 VAN) 36,261 S.F. / 4,029 S.Y. W.M. W.V. FP
X
ORIGIANL WITHOUT HOUSE: 517
W.M.
27 X
32 10 9 17
24x36
32 32 AC
24x36
33 60" 33 27 X
29 FP 0 20 40 80
32 W.V.
AC
31 28 W.V. X
24x36 PROPOSED 30 27 D. 3 ONE STORY
FRAME
24x36
E
30
31
CONCRETE SIDEWALK 29 17 BUILDING 176 X Do Not Explode - Select Scale
34" 28
F.H.
W.V. 5,044 SQ. FT.
FP .50'
SCALE: 1" = 40'
24x36
34' 32 AC X 24x36
27 F.M.
EX. 24" R.C.P. N 1°
SCULL TERRACE
33
34 33 32
27
26 EX.
30"
26
X
N 78° 28' 32
X E
ISSUE BLOCK
FP X "E
24x36
10' SIDE YARD FLOODPLAIN LINE 24x36
25.33'
37.87'
OE OE OE SETBACK LINE
.
OE OE 12
OE 26 18 23
S 11° 54' 41"
W.M
.
F.H OE OE
24x36 OE OE OE 24x36
W.V
. FCM 18"
FCM 121.55' FP
24"
.
W.V
W.V
.
1115.96' 12 12 12 12 12 12 12
S 72° 59' 55" W
10"S
X
29
.P.
15 0 15
EX. R.C
30 30
24x36 45 45
24x36
60 60
75
90
75
90 X
24" 75
60
75
60
45 45
30 30
EX.
15 0 15
FP
12
20' WIDE KENT COUNTY X
LANDS N/F
UTILITY EASEMENT 1 03/25/21 REVISED PHASE 1 - THE EXISTING
TO REMAIN - PARKING REDUCED BY 39.
8"S
24x36
30 OE CHURCH OF THE HOLY CROSS, DOVER, DELAWARE EX.
24x36
X MARK DATE DESCRIPTION
30 T.P.: 2-05-07713-01-5600-00001 12
1
LAYER STATE: C-201
DEED REF.: Q-0020-0165 X
ZONING - IO X X X FP PROJECT NO.: 2019184-07
24x36 30 X 24x36
EX.
12"
30
29
X
DATE: 2021-03-25
R.C
.P
28 12 X
. 27
X SCALE: AS SHOWN
20'
24x36
FP DRAWN BY: M.A.R. PROJ. MGR.: M.A.R. 24x36
X
12
X SHEET
OE
X 20' WIDE CITY OF DOVE
24x36
24"
12
UTILITY EASEMENT
R X
FP
C-201
COPYRIGHT 2020
24x36
119
C-201 - BayHealth Scull Property - Phase 1 Revised - 2021-03-25
24x36
F:\AutoCAD\Projects\2019\2019184-07\DWG\201918407-Site-C3d18-DAC.dwg, Mar 25, 2021 - 9:56am 24x36
Page 120
24x36 24x36
Item 7.
WWW.beckermorgan.com
LANDS N/F FP
E
X
RAC
RICHARD J. KOSIOR
24x36
& KATHLEEN P. KOSIOR
T.P.: 2-05-07709-05-7100-00001 FP
FP ELM TER 24x36
DEED REF.: 5045-0067 LANDS N/F
LANDS N/F MICHAEL GRANT X
MATHEW PERZA ZONING - R8
& RACHEL GRANT
EET
T.P.: 2-05-07709-05-7101-00001 FP N N
STR
DEED REF.: 8452-0199 T.P.: 2-05-07709-05-6500-00001
FP
ZONING - R8 DEED REF.: 9012-0298
ER
24x36
ZONING - R8 FP WAT 24x36
LANDS N/F
X
N 78° 25' 47 DENNIS J. GRIMM
FCM
"E FP T.P.: 2-05-07709-05-6400-00001
DEED REF.: 5079-0078 LANDS N/F 605 S. STATE ST.
N 16° 12' 10" W 75.44'
.
H ST
FIP ZONING - R8 X
KATHLEEN M. UNTERKOFLER 2-05-07713-01-4900-00001
T
SOU
T.P.: 2-05-07709-05-6300-00001
24x36
FP DEED REF.: IS-0026-0405 LANDS N/F 3.45 AC. 24x36
FP ZONING - R8 LISA MARIE ROSSI
SITE
FP
343.96' T.P.: 2-05-07709-05-6200-00001 X
LIMITS OF PHASE 10'3SIDE YARD SETBACK LINE
FP
FP F DEED REF.: 7048-0014
SP
FIR
ZONING - R8
68 X X TOTAL: 11.43 AC.± ARCH I T E C TURE
PARKING ADDITION
V X
°
48.98'
SITE
B ECKER M ORGAN G ROUP ARCHITECTURE - ENGINEERING DOVER, DE SALISBURY, MD WILMINGTON, NC
V X
26.45'
FP X
06 FP FP X
24x36 24x36
V V
X X FP 150 SCULL TERRACE
'3 FP
FP X FP 2-05-07713-01-5100-00001 ENG I NE E R I NG
3"
SOUTH GOVERN
FP 7.98 AC.
Y
FP
SOUTH STATE STREET
SCM FP FIP
E FP HWA
FP
Dover, DE
X
FIR V VFP FP
SOUTH STATE STREET
HIG
ORS AVENUE
24x36 24x36
X 309 S. Governors Ave.
V LANDS N/F
MOLLY B. PHILLIPS FP
NT Dover, DE 19904
APPROXIMATE LOCATION 12 T.P.: 2-05-07709-05-6100-00001
FP UPO Ph. 302.734.7950
FP OF 100 YEAR FLOOD PLAIN 7. DEED REF.: 7372-0173 X
24x36
24" 24" 30"
16 ZONING - R8 LANDS N/F
DONALD L. HENRY
FP Fax 302.734.7965 24x36
SOU
24"
FP
V ' T.P.: 2-05-07709-05-6000-00001
N 87
° 59'
DEED REF.: 5775-0149
LANDS N/F
X
TH Salisbury, MD
D
36" FP ZONING - R8
V 32" E GIA DOWNTOWN
FP FP
24x36
96" V
PROPERTIES, LLC
T.P.: 2-05-07709-05-5901-00001
312 West Main St. Suite 300 24x36
FP Salisbury, MD 21801
X
DEED REF.: 8444-0331
HOPE ST.
5
ZONING - R8
FP FIP V Ph. 410.546.9100
FP 152. CITY OF DOVER - KENT COUNTY, DELAWARE
FP 09' Fax 410.546.5824
V N 77° 42' 04"
LOCATION MAP VICINITY MAP
X
FP
V E FP
SCALE: 1" = 400' SCALE: 1" = 1000'
Wilmington, NC
24x36
LANDS OF
24x36
RADIUS: 1462.69' 50.03'
BAYHEALTH MEDICAL CENTER, INC V
S 15° 02' 25" E
2019184-07-V-Map-400 2019184-07-V-Map-1000
ARC LENGTH: 284.55' V 3333 Jaeckle Drive, Suite 120
X
7.58'
CHORD BEARING: N 10° 37' 47" W V
SITE DATA - SCULL MANSION PROPERTY
48"
TOTAL AREA: 11.43 ACRES± FP Xref-Phase-1-Parking-Blk FCM
.90' V Wilmington, North Carolina 28403
CHORD LENGTH: 284.10' 108 47" W
Xref-Phase-2-Parking-Blk
2019-184-Site-Data-001
Ph. 910.341.7600
24x36 24x36
Xref-Phase-3-Parking-Blk
34'
FP FP
1. OWNER OF RECORD: BAYHEALTH MEDICAL CENTER, INC
52°
X
Fax 910.341.7506
48"
10
24"
S C/O MIKE METZING VP, CORPORATE SUPPORT SERVICES
640 SOUTH STATE STREET
www.beckermorgan.com
5'
X
DOVER, DE 19901
74.9 FP
24x36 24x36
FP
18 9
.85'
2. ENGINEER / SURVEYOR: BECKER MORGAN GROUP INC.
15' REAR YARD
183
X FP
48" FP 309 SOUTH GOVERNORS AVE.
SETBACK LINE
70.00' S 15° 02' 25" E
FP
TWO STORY
FP DOVER, DELAWARE 19904
24x36
BRICK
302-734-7950
24x36
X
BUILDING
2,743 SQ. FT. LANDS N/F
RADIUS: 1462.69' CITY OF DOVER 3. PROPERTY LOCATION: 150 SCULL TERRACE & 605 S. STATE ST.
T.P.: 2-05-07713-01-5700-00001
LIMITS OF PHASE 1
ARC LENGTH: 462.51' 10
6 DEED REF.: 5011-0121
X
DOVER, DE 19901
FP
CHORD BEARING: N 7° 08' 39" W ZONING - IO FP
PARKING ADDITION
4. TAX PARCEL NUMBERS: 2-05-07713-01-4900-00001 605 S. STATE ST. 3.45 AC.
24x36 24x36
CHORD LENGTH: 460.59' 48"
X
(PARCELS TO BE CONSOLIDATED) 2-05-07713-01-5100-00001 150 SCULL TERRACE 7.98 AC.
APPROXIMATE LOCATION LANDS N/F
OF 100 YEAR FLOOD PLAIN FP CITY OF DOVER 5. ZONING CLASSIFICATION: IO - INSTITUTIONAL AND OFFICE (CITY OF DOVER)
60"
ONE STORY X
T.P.: 2-05-07713-01-5000-00001 SWPOZ TIER 1 AND 3 - SOURCE WATER PROTECTION OVERLAY ZONE
FRAME
N 74° 57' 34" E
24x36 24x36
FP DEED REF.: T-0036-0203
BUILDING
1,112 SQ. FT. 170.01' ZONING - IO 6. DEED REFERENCE: D-657-20 & S-39-127
S 15° 02' 25" E
71.52'
10 34 98.49'
X
V 7. SITE AREA (AFTER CONSOLIDATION): 11.43 ACRES
24x36 10 FP X 8. SETBACKS: IO - INSTITUTIONAL AND OFFICE 24x36
V
FP
24"
V STREET YARD: 10 FEET
PROPERTY LINE TO BE SIDE YARD: 10 FEET
EXTINGUISHED PER THE FP V X
REAR YARD: 15 FEET
FP
24x36
CONSOLIDATION PLAN V SIDE/REAR ADJOINING "R" ZONES: 30 FEET 24x36
60"
30" FP
9. BULK STANDARDS: IO - INSTITUTIONAL AND OFFICE
X
20' FRONT YARD FIP
MINIMUM AREA: 10,000 SQ. FT.
80.00'
SETBACK LINE 30"
X X 36 21 X MINIMUM FRONTAGE: 100 FEET
36"
24"
24x36 24x36
S8 MINIMUM DEPTH: 100 FEET
RADIUS: 1462.69' 30" ONE STORY 7° 2 BUILDING HEIGHT: 150 FEET/10 STORIES
POLE X 9' 2
290
294 197
ARC LENGTH: 177.96' X 2" E FLOOR AREA RATIO: 6.0
CHORD BEARING: N 1° 34' 16" W
BUILDING
1,440 SQ. FT. N 73° 01' 53" E X 78.4 MAX LOT COVERAGE: 85%
28.34' 8'
CHORD LENGTH: 177.86'
EET
24x36
X 24x36
30 S 10. USE: EXISTING: MEDICAL FACILITY
74
"
10 °5
X PROPOSED:MEDICAL FACILITY
0'
58 11. ROAD CLASSIFICATION: SOUTH STATE STREET - MINOR ARTERIAL - 25 MPH
STR 38 34 "E
X
24x36 24x36
X 12. PROPERTY LOCATION: LATITUDE: N 39° 09' 13.08" GRS80 - NAD83 (2011)
LIMITS OF PHASE 3LIMITS OF PHASE 2
TWO STORY
LONGITUDE: W 075° 31' 23.25" GRS80 - NAD83 (2011)
60
FRAME BUILDING X
1,044 SQ. FT.
PARKING ADDITION PARKING ADDITION
FP 13. SURVEY DATUM: NGS MONUMENTS
FO
X
TE VERTICAL: NAVD 88 - XX
24x36 24x36
KCR OT W
X FP
HORIZONTAL: NAD 83 (2011) DSP - XX
X
STA
14. SURVEY UNIT: LINEAR: US SURVEY FOOT
25, IDE R
X
FP
18 ANGULAR: DEGREES MINUTES SECONDS (DMS)
42 34 3.8 FP
24x36 24x36
X COORDINATE TYPE: GROUND
8' FP
19 13
MIN I
OR GHT O
X
15. MONUMENTATION: 8 FOUND / 7 SET
9 FP
TH
30"
184
16. SURVEY CLASSIFICATION: SUBURBAN SURVEY
TWO STORY
24x36 24x36
S 34
PROJECT TITLE
ART F W
FP
.88'
STUCCO BUILDING
X
17. UTILITIES: SEWER - CITY OF DOVER
SOU
2,100 SQ. FT.
BAYHEALTH
WATER - CITY OF DOVER
° 35
ERI A
ELECTRIC - CITY OF DOVER
AL Y
X
17 GAS - CHESAPEAKE UTILITIES
' 27"
MEDICAL
24x36 24x36
EXISTING ONE-STORY
44 COVERED
ENTRANCE BRICK 38
BUILDING 26 FP X 18. PREDOMINANT SOILS: SaB: SASSAFRAS SANDY LOAM, 2 TO 5 PERCENT SLOPES
OUTPATIENT SURGERY CENTER E
CENTER, INC
19. MAXIMUM LOT COVERAGE: 85%
17 10,800 S.F. ± - FOOTPRINT X
24x36
15' REAR YARD 20. IMPERVIOUS COVERAGE: IO ZONING - 85% PERMITTED 24x36
193
27"
SETBACK LINE POST PHASE 3: PROPOSED 5.5 AC. / 11.43 AC. = 48%
FP X
21. OUTDOOR LIGHTING: LIGHTING SHALL BE 1.5 FOOT CANDLES (MINIMUM) AT GRADE
SCULL PROPERTY
SITE DEVELOPMENT
24x36 24x36
X
10 9 17 19 13
60"
FP
X MASTER PLAN
BAYHEALTH STAFF
24x36 24x36
D.
ONE STORY X
17 19 13
E FRAME
34" BUILDING 176 PARKING LOT
5,044 SQ. FT. X
.50'
24x36
34' FP EXPANSION 24x36
N 1° SCULL TERRACE 98 X
N 78° 28' 32
E 605 S. STATE STREET
X "E CITY OF DOVER
25.33'
10' SIDE YARD FLOODPLAIN LINE
37.87'
24x36 24x36
12 18 2020 13 SETBACK LINE FP KENT COUNTY, DELAWARE
FCM
18"
FCM 121.55' S 11° 54' 41" SHEET TITLE
24"
1115.96' S 72° 59' 55" W
COVER SHEET
24x36 24x36
X
15 0 15
30 30
45 45
FP
60 60
75 75
90
75
60
90
75
60
X
45 45
30 30
20' WIDE KENT COUNTY
15 0 15
LANDS N/F
24x36 24x36
UTILITY EASEMENT X
CHURCH OF THE HOLY CROSS, DOVER, DELAWARE
T.P.: 2-05-07713-01-5600-00001
DEED REF.: Q-0020-0165
X
ZONING - IO X
X X FP
24x36 24x36
X X
X
20'
X
24x36 24x36
X FP
X
X 20' WIDE CITY OF DOVE
24" R
UTILITY EASEMENT X
24x36 24x36
0 25 50 100
GENERAL NOTES: GENERAL NOTES: 2019-184-General-Notes-L-001
1. THE BOUNDARY & TOPOGRAPHIC DATA SHOWN HEREON WAS COMPILED FROM A FIELD SURVEY 11. ALL CONSTRUCTION METHODS AND MATERIALS SHALL BE ACCORDANACE WITH THE CITY OF DOVER
24x36 24x36
PERFORMED BY BECKER MORGAN GROUP, INC. , DOVER, DE. IN APRIL 2020. PROJECT VERTICAL DATUM IS DEPARTMENT OF PUBLIC UTILITIES CONSTRUCTION STANDARDS AND SPECIFICATIONS AND THE STATE OF Do Not Explode - Select Scale
BASED ON NAVD 88 AND PROJECT HORIZONTAL DATUM IS BASED ON DELAWARE STATE PLANE (NAD83),
GPS DERIVED FROM N.G.S. CONTROL MONUMENTS.
DELAWARE CONSTRUCTION STANDARDS AND SPECIFICATIONS. SCALE: 1" = 50'
12. ALL FIRE LANE DEMARCATION AND FIRE LANE SIGNS SHALL BE IN ACCORDANCE WITH ALL THE STATE FIRE
PREVENTION REGULATIONS.
24x36 24x36
2. THE BOUNDARY LINES PORTRAYED HEREON HAVE BEEN ESTABLISHED BASED SOLELY ON PHYSICAL
EVIDENCE DISCOVERED IN THE FIELD IN CONJUNCTION WITH DETERMINATIONS DERIVED FROM SOURCE OF ISSUE BLOCK
13. EASEMENT AGREEMENT WITH AND FOR THE BENEFIT OF HOLY CROSS CHURCH FOR PURPOSE OF INGRESS
TITLE AND ADJACENT DEED RECORD INFORMATION. AND EGRESS ACROSS LANDS OF KENT GENERAL HOSPITAL, INC. (P. 51.00) SHOWN HEREON, IN DEED BOOK
24x36
3. ALL UTILITY LOCATIONS AND SIZES SHOWN HEREON ARE EITHER MARKED LOCATIONS IN THE FIELD, O47 PAGE 063 DATED JANUARY 30, 1987 AND RECORDED IN THE KENT COUNTY OFFICE OF RECORDER OF
DEEDS.
ENGINEERS CERTIFICATION 2019-184-Engineers-Cert PARKING SUMMARY - BAYHEALTH MEDICAL CENTER CAMPUS 24x36
VISIBLE AND FIELD LOCATED STRUCTURES OR TAKEN FROM UTILITY MAPS PROVIDED BY UTILITY
2019-184-Parking-Data-001
PROVIDERS. HOWEVER, LACKING EXCAVATION, THE EXACT LOCATION OF UNDERGROUND FEATURES 14. THE SUBJECT SITE IS WITHIN A DOWNTOWN REDEVELOPMENT TARGET AREA AND THEREFORE, EXEMPT I, GREGORY V. MOORE, HEREBY CERTIFY THAT I AM A REGISTERED ENGINEER IN THE STATE OF DELAWARE, 1. SUBJECT AREA: 38.47 ACRES ± / 1,676,139 S.F. ±
CANNOT BE ACCURATELY, COMPLETELY AND RELIABLY DEPICTED. FROM THE REQUIREMENTS AND RESTRICTIONS OF THE SOURCE WATER PROTECTION OVERLAY ZONE THAT THE INFORMATION SHOWN HEREON HAS BEEN PREPARED UNDER MY SUPERVISION AND TO THE BEST OF
2. NUMBER OF EMPLOYEES: 2,052 (TOTAL STAFF)
24x36
4. THE AREA OF DEVELOPMENT SHOWN HEREON IS NOT IMPACTED BY THE 100 YEAR FLOOD ZONE AS SHOWN (SWPOZ), TIER 3 - EXCELLENT RECHARGE AREA. MY KNOWLEDGE AND BELIEF REPRESENTS GOOD ENGINEERING PRACTICES AS REQUIRED BY THE APPLICABLE 24x36
ON KENT COUNTY, DELAWARE FIRM MAP 10001C0169J, PANEL 169, REVISED JULY 7, 2014. PORTIONS OF LAWS OF THE STATE OF DELAWARE.
15. THE IMPROVEMENTS SHOWN FOR THE PROJECT SITE ARE NOT LOCATED WITHIN THE SOURCE WATER AREA EXISTING POST POST POST
THE OVERALL PROPERTY ARE LOCATED WITHIN ZONE "X", AREA OF MINIMAL FLOOD HAZARD. PROTECTION OVERLAY ZONE (SWPOZ), TIER 1 - SECONDARY WELLHEAD PROTECTION AREAS. PHASE 1 PHASE 2 PHASE 3
5. WETLANDS SHOWN HEREON WERE FIELD LOCATED BY BECKER MORGAN GROUP, AS DELINEATED BY 16. THE PROPERTY WAS PREVIOUSLY SUBMITTED TO THE PLANNING COMMISSION AND WAS GRANTED "ON-CAMPUS" HOSPITAL PARKING: 1,132 1,132 1,132 1,132
24x36
BY WATERSHED ECO, LLC. THE AREA OF DEVELOPMENT SHOWN HEREON IS NOT IMPACTED BY APPROVAL OF THE SITE PLAN ON MAY 20, 2013 WITH THE FOLLOWING DECISIONS: 24x36
FRESHWATER WETLANDS. GREGORY V. MOORE P.E. NO. 9311 DATE "OFF-CAMPUS" HOSPITAL PARKING: 242 242 242 242
1. APPROVED A WAIVER FOR ELIMINATION OF PORTIONS OF UPRIGHT CURBING TO ALLOW THE FLOW OF
6. ALL ROADS, PARKING AND OTHER PAVED AREAS WILL BE PRIVATELY OWNED AND MAINTAINED AND ARE STORMWATER RUNOFF INTO THE STORMWATER MANAGEMENT AREA. SCULL PROPERTY PARKING 227 517 589 680 .
NOT INTENDED FOR DEDICATION. 2. APPROVED THE USE OF JOINT PARKING FACILITIES PROVISIONS WHICH WILL ALLOW THE PROPOSED . . .
TOTAL CAMPUS PARKING 1,601 1,891 1,963 2,054
7. PARKING FOR THIS PROJECT TO BE COMBINED WITH THE EXISTING PARKING PROVIDED ON THE MAIN
24x36
DELAWARE REGULATIONS PROHIBIT THE BURIAL OF CONSTRUCTION DEMOLITION DEBRIS, INCLUDING
24x36
MARK DATE DESCRIPTION
TREES AND STUMPS ON CONSTRUCTION SITES. ANY SOLID WASTE FOUND DURING EXCAVATION MUST BE BAYHEALTH MEDICAL CENTER FACILITIES. LAYER STATE: C-001
8.
REMOVED AND PROPERLY DISCARDED.
ALL ACCESSIBLE PARKING DEMARCATION, STALLS, AND BUILDING ACCESSIBLE ROUTES SHALL COMPLY
3. BASED ON DISCUSSIONS BETWEEN BAYHEALTH MEDICAL CENTER AND HOLY CROSS CHURCH & SCHOOL,
THE FOLLOWING CONDITIONS WERE MET:
OWNERS CERTIFICATION 2019-184-Owners-Cert SHEET INDEX 2019-184-Sheet-Index PROJECT NO.: 2019184-07
A. THE PARALLEL PARKING SPACES ON THE SOUTH SIDE OF THE ENTRANCE DRIVE (SCULL TERRACE)
C-001 COVER SHEET DATE: 2020-09-04
24x36 24x36
WITH THE "AMERICANS WITH DISABILITIES ACT". WE, BAYHEALTH MEDICAL CENTER, INC., HEREBY CERTIFY THAT WE ARE THE OWNER OF THE PROPERTY
ADJACENT TO THE HOLY CROSS PROPERTY BETWEEN SOUTH STATE STREET AND HOLY CROSS DESCRIBED AND SHOWN ON THIS PLAN, THAT THE PLAN WAS MADE AT OUR DIRECTION, AND THAT WE
9. THIS DRAWING DOES NOT INCLUDE NECESSARY COMPONENT FOR CONSTRUCTION SAFETY. ALL
CONSTRUCTION MUST BE DONE IN COMPLIANCE WITH THE OCCUPATIONAL SAFETY AND HEALTH ACT OF
ENTRANCE ARE TO BE ELIMINATED. ACKNOWLEDGE THE SAME TO US BY ACT AND DESIRE THE PLAN TO BE DEVELOPED AS SHOWN IN ACCORDANCE
C-101 EXISTING CONDITION SCALE: AS SHOWN
1970 AND ALL RULES AND REGULATIONS THERETO APPURTENANT.
B. THE PARALLEL PARKING SPACES ON THE SOUTH SIDE OF THE ENTRANCE DRIVE (SCULL TERRACE)
WITH ALL APPLICABLE LAWS AND REGULATIONS. C-201 SITE PLAN - PHASE 1
ADJACENT TO THE HOLY CROSS PROPERTY AND EAST OF THE HOLY CROSS ENTRANCE ARE TO BE DRAWN BY: M.A.R. PROJ. MGR.: M.A.R.
24x36 24x36
10. BEFORE THE CONTRACTOR CAN BEGIN CONSTRUCTION HE MUST OBTAIN THE PROPER PERMITS AND/OR ELIMINATED. C-202 SITE PLAN - PHASE 2
APPROVALS FROM THE CITY OF DOVER (C.O.D.), DELAWARE DEPARTMENT OF NATURAL RESOURCES SHEET
(D.N.R.E.C.), DELAWARE DEPARTMENT OF TRANSPORTATION (DELDOT), CITY OF DOVER DEPARTMENT OF
C-203 SITE PLAN - PHASE 3
24x36
PUBLIC WORKS, CITY OF DOVER DEPARTMENT OF PUBLIC UTILITIES AND APPROPRIATE STATE AND
COUNTY AGENCIES.
MIKE METZING VP, CORPORATE SUPPORT SERVICES DATE L-101
1
LANDSCAPE PLAN
LOT CONSOLIDATION PLAN C-001
COPYRIGHT 2020
24x36
C-001 - BayHealth Scull Property
120
24x36
F:\AutoCAD\Projects\2019\2019184-07\DWG\201918407-Site-C3d18.dwg, Sep 04, 2020 - 12:41pm 24x36
Page 121
24x36 24x36
Item 7.
UE X LEGEND
FP
ITEM EXISTING PROPOSED
24x36 24x36
12
X
SANITARY GRAVITY SEWER LINE, EX. 10"S 10" S
FP SIZE & FLOW DIRECTION
OT FP
X
SANITARY SEWER FORCE MAIN, SIZE
24x36 24x36
LANDS N/F FP
EX. 10" F.M. 12" F.M.
12 & FLOW DIRECTION FP
18 U.T. RICHARD J. KOSIOR
U.T. & KATHLEEN P. KOSIOR FP
SANITARY SEWER MANHOLE (S.M.H.)
X
T.P.: 2-05-07709-05-7100-00001
DEED REF.: 5045-0067 P LANDS N/F
24x36 LANDS N/F F MICHAEL GRANT SANITARY SEWER CLEANOUT 24x36
MATHEW PERZA ZONING - R8 X
EX. 15"S
T.P.: 2-05-07709-05-7101-00001
& RACHEL GRANT FP EX. 10" W 12" W
12
FP T.P.: 2-05-07709-05-6500-00001 WATER MAIN & SIZE
RCP DEED REF.: 8452-0199
EX. 48" OT ZONING - R8 DEED REF.: 9012-0298 FP
ZONING - R8 FIRE HYDRANT F.H. F.H.
ARCH I T E C TURE
EX. 6"W
X
24x36 24x36
EX. 15"S LANDS N/F WATER VALVE (W.V.) OR METER (W.M.)
N 78° 25' 47 FP
DENNIS J. GRIMM
T.P.: 2-05-07709-05-6400-00001 FP
W.M. W.V. W.M. W.V. ENG I NE E R I NG
" EEX. 48" RC
X
FCM DEED REF.: 5079-0078 LANDS N/F STORM DRAIN MANHOLE (S.D.M.H.)
PFIP
Dover, DE
N 16° 12'
ZONING - R8 KATHLEEN M. UNTERKOFLER
10" W 75.44'
FP
EX. 15"S
12
T.P.: 2-05-07709-05-6300-00001
24x36
STORM DRAIN LINE (CMP OR RCP)
24x36
X
U.T.
FP
FP
DEED REF.: IS-0026-0405 LANDS N/F
LISA MARIE ROSSI
309 S. Governors Ave.
OT ZONING - R8
T.P.: 2-05-07709-05-6200-00001 CATCH BASIN Dover, DE 19904
FP 343.96'
EX. 12"S
FP
Ph. 302.734.7950
X
FIR DEED REF.: 7048-0014
FP FP ZONING - R8 UTILITY POLE W/ OVERHEAD SERVICE
24x36
S (TELEPHONE X
X OR ELECTRIC OR BOTH) FP Fax 302.734.7965 24x36
48.98'
68 V X
26.45'
V X
U.T.
18 17 16 15 10' SIDE YARD SETBACK LINE °0 FP
"S EX. 15
V
FP FP
X X X X
UNDERGROUND ELECTRIC U.E. U.E. Salisbury, MD
14 6' X FP
FH 18 EX
V V
FP X X FP
FP X
. 4 33 FP
FP UNDERGROUND TELEPHONE U.T. U.T. 312 West Main St. Suite 300
24x36
8" "E FP FP 24x36
SCM 12 FP FIP RC FP UNDERGROUND GAS MAIN EX. 2" G 2" G Salisbury, MD 21801
P FP EX. 15"S
X
W.V FP
Ph. 410.546.9100
V V
. FIR FP FP
OE OE PAVEMENT TO BE REMOVED N/A
188
OE OE OE
Fax 410.546.5824
1 OE OE
X
112 OE OE CONCRETE CURB & GUTTER
OE OE OE
Wilmington, NC
24x36 24x36
2 OE OE OE OE OE OE
V
LANDS N/F OE OE
CONCRETE SIDEWALK, SLAB / PAVING
13 MOLLY B. PHILLIPS
APPROXIMATE LOCATION FP
3333 Jaeckle Drive, Suite 120
X
EX. 8"S FP
T.P.: 2-05-07709-05-6100-00001 FP
W.V
. 11 OF 100 YEAR FLOOD PLAIN V 12 DEED REF.: 7372-0173 IMPERVIOUS SURFACED ROAD, DRIVE
Wilmington, North Carolina 28403
W.V W
24" 24" 30" 14 12 7. ZONING - R8 LANDS N/F OR LOT FP
24x36
EX. 8"W
.
13 16 FP Ph. 910.341.7600
.V.
24x36
24" DONALD L. HENRY X
.
15 14 FP ' T.P.: 2-05-07709-05-6000-00001 INDIVIDUAL TREE OR BUSH N/A
UT
W.V
UT 15 FP V DEED REF.: 5775-0149 EVERGREEN DECIDUOUS Fax 910.341.7506
16 36" 16 N 87 ZONING - R8 LANDS N/F X X X
° 59' WIRE FENCE X X X
www.beckermorgan.com
X
GIA DOWNTOWN FP
FP V 32" E PROPERTIES, LLC CHAINLINK FENCE FP
17 18 19
17 V
96"
24x36
19 24x36
FP T.P.: 2-05-07709-05-5901-00001 X STOCKADE FENCE
18 DEED REF.: 8444-0331
OE FP
V ZONING - R8
FIP
FP STRUCTURE (CONCRETE, WOOD,
19 FP V 152. FP
METAL, ETC.)
09'
LIMITS OF PROPOSED FP
U.T. FP
24x36 24x36
X
N 77° 42' 04"
EX. 12"S
U.T. V
20 20 E DRAINAGE DITCH OR SWALE
RADIUS: 1462.69'
PARKING IMPROVEMENTS V
V 50.03' EMBANKMENT SIDESLOPES (DOWN)
21 S 15° 02' 25" E
24x36
ARC LENGTH: 284.55' V X CONTOUR 49 55
24x36
CHORD BEARING: N 10° 37' 47" W 48" 21 V
V
7.58' FP
22 FCM 43.55 FP
.90'
CHORD LENGTH: 284.10'
FP
V ELEVATION SPOT SHOT 25.50 T.C.
25.15
108 47" W 25.00 B.C.
20
23
34'
BENCH MARK
X N/A
52°
24x36 24x36
22
48" 24" S PROPERTY OR RIGHT-OF-WAY LINE
23 X FP
AC
CENTERLINE
FP
24 FP
5' LIGHT POLE FP
24 25
74.9
24x36 24x36
X
N/A
.85'
CONSTRUCTION NOTE
26
48" 15' REAR YARD FP
183 EX. 18"S
10 1
21 FP
SETBACK LINE
X
27 FP
25 TWO STORY 1 2
S 15° 02' 25" E
24x36
FP 24x36
BRICK 1
BUILDING 13 4 FP X
LANDS N/F
2,743 SQ. FT. 1 5
RADIUS: 1462.69' 1 6 CITY OF DOVER
1 T.P.: 2-05-07713-01-5700-00001
17 8
X
24x36
ARC LENGTH: 462.51' 22 24x36
DEED REF.: 5011-0121
CHORD BEARING: N 7° 08' 39" W 26 EX. SD. CB 1 9 FP
1 ZONING - IO
20 1
CHORD LENGTH: 460.59' 48" GRATE: 27.49' FP X
INV.: 26.06' FP
2 2
24x36
AC 2 APPROXIMATE LOCATION LANDS N/F 24x36
"S
23
X
70.00'
EX. 12 23 60" 24 OF 100 YEAR FLOOD PLAIN CITY OF DOVER
ONE STORY
27 FRAME
25 T.P.: 2-05-07713-01-5000-00001
26 N 74° 57' 34" E FP
X
DEED REF.: T-0036-0203
BUILDING
24x36
28 1,112 SQ. FT.
27 170.01' FP ZONING - IO 24x36
71.52'
98.49'
S 15° 02' 25" E
X
V
28 FP
24 5
3 V X
FP
24x36 24x36
V
24"
28 FP
PROPERTY LINE TO BE V X
29 EXTINGUISHED PER THE V
FP
FP
CONSOLIDATION PLAN V
24x36 24x36
X
25 29
60"
25 30" TV
26 UE FP
20' FRONT YARD
X
FIP
80.00'
9
SETBACK LINE OT
27
30
24x36 24x36
30" OE OE OE OT TV PROJECT TITLE
36"
X X X OE 10
UT
X
11
BAYHEALTH
24"
28 OT 265 12
30" 31 14 EX. SD. CB ONE STORY 2 4 13 S8
RADIUS: 1462.69' GRATE: 29.22' 2 14 7° 2
X
POLE 9' 2
MEDICAL
29
EX. 15" R.C.P.
245
24x36 24x36
X
ARC LENGTH: 177.96' 26
31 15" INV.: 25.56'
BUILDING TV 15 2" E
CHORD BEARING: N 1° 34' 16" W
UT
1,440 SQ. FT.
26
2 16 N 73° 01' 53" E X
17 28.34' X 78.4
EET
CHORD LENGTH: 177.86' EXISTING ASPHALT 18 8'
CENTER, INC
X
EX. SAN. MH.
30" PARKING AREA
15 19
OT EX. 15"
R.C.P. 20 RIM EL.: 13.81' S
74
24x36 24x36
EX. 15" RCP X
30 21
EX. SD. CB INV: 25.22'
UE 22 °5
GRATE: 30.91' EX. 15" R.C.P. 0'
X
SCULL PROPERTY
23 5
.
W.V 15" INV.: 25.86' TV 8"
STR
11 "S
6
.
W.M 31 X.
X E
SITE DEVELOPMENT
UT UE E
EX. SD. M.H. 24
24x36 24x36
EX. SD. M.H. G.M. X
RIM: 29.62' RIM: 28.64' TWO STORY 26 20
MASTER PLAN
KCR OT W
11 15" INV.: 25.52' 15" INV.: 25.48' T FRAME BUILDING X
U 25 EX. 6"S
OT 1,044 SQ. FT.
5 X FP
24 3
TE
25
BAYHEALTH STAFF
24x36
2 FP
24x36
25, IDE R
EX. CLEANOUT X
32 EX. 6"S 23 4 LID: 26.81'
INV.: 22.23'
30 29 2
PARKING LOT
EX. 12" STEEL X
31 UE
19
32 28 EX. SIGN TV
25 UT X
STA MIN IG
FP FP
TV
EXPANSION
UT G UT EX. C.B.:
UT 27 12" STEEL - MD - 7.13'
26 26.64'
27
OR HT O
UT EX. C.B.:
TV GRATE:
24x36 24x36
X
UT UT
G UE G EX. 30" F.M.
UE UT
GRATE: 26.88'
26
4" PVC - MD - 2.01'
UE UE 10 UE UE ELECTRIC
UEPANEL FP
UE UE X 18
OT
UE
UE UT
TV
26 EX. C.B.: 3.8 605 S. STATE STREET
8
ART F W
FP
8" PVC - MD - 5.55'
G
8" PVC - MD - 5.84'
X
GRATE: 27.01' ' CITY OF DOVER
MD: -4.58'
17 SHED FP
4" PVC - MD - 2.34'
TV
4" PVC - MD - 1.66'
4" PVC - MD - 1.70'
G
X
24x36 24x36
8" PVC - MD - 3.84'
UE KENT COUNTY, DELAWARE
A
8" PVC - MD - 3.53'
ERI
UTTV
G.M.
SOU
30" 33 FP
AL Y
28
UT FP X
SHEET TITLE
TWO STORY
12"S
TH
STUCCO BUILDING UT
34
S 34
EXISTING
24x36 24x36
2,100 SQ. FT. G.M.
EX. G X
60 UT
° 35
FO CONDITIONS PLAN
EX. 10" WATER
EX. 6" C.B.:
11 26 GRATE: 25.86'
FP X
' 27"
UT
EX. 18"S
TV
EXISTING ONE-STORY
24x36 24x36
.P. UT
R.C
.88' UT UT 33 32 COVERED
ENTRANCE BRICK BUILDING X
E
UT
TOTAL PARKING
24"
EX.
184 UT
31 OUTPATIENT SURGERY CENTER
24x36 30 G 16 10,800 S.F. ± - FOOTPRINT FP X 24x36
SPACES: 227
UT
15' REAR YARD
26
27" UT EX. 1' C.B.:
GRATE: 25.62'
29
3 UT 28 27 TV 26 SETBACK LINE X
EXISTING ASPHALT
UT PARKING AREA
24x36
UT UT UT UT GEN
24x36
28
X
FP
G UT W.M. W.V.
W.M.
27 X
10 17
32 32 32 G UE
24x36 24x36
27
AC
G 33 60" 33 7 X
29
32
TV
W.V.
AC
FP 0 20 40 80
UT UT TV 28 EX. 8" W
W.V. X
31 UT 3 ONE STORY
24x36
30 LIGHT POLE 27 D.
FRAME
24x36
30 G (typ.)
176
E 29
31 G 16 BUILDING Do Not Explode - Select Scale
SCALE: 1" = 40'
X
34" G G G G.V. 28 5,044 SQ. FT.
F.H. .50'
W.V.
FP
32 6 TV AC
24x36
34' X 24x36
27 F.M.
EX. 10" W
33 27 EXISTING ISSUE BLOCK
N 1°
SCULL TERRACE
EXISTING ASPHALT CONCRETE CURB 30"
34 UT UT
EX. 24" R.C.P.
UT
X
33 32 PARKING AREA
UE
EX.
26 N 78° 28' 32
"E
X
E
10' SIDE YARD FLOODPLAIN LINE FP X
UTILITY POLE (typ.) EXISTING
24x36 24x36
25.33'
UT UT WHEELCHAIR RAMP 37.87'
TV UE OE UE OE
OE G G G 43
SETBACK LINE
UE UE TV OETV TV G 26 G
TV TV UE G G
S 11° 54' 41"
W.M
.
TV UE OE UE
TV UE
.
F.H
TV OE UE OE
OE TV 121.55'
24x36 24x36
FCM UE FCM
.
W.V
18" UE UE UE FP
24"
.
W.V
.
W.V 1115.96' 12 12 12 12 12 12 12
S 72° 59' 55" W
10"S
X
29
.P.
EX. SAN. MH.
15 0 15
R.C
30 30
24x36
EX. 60
45 45
60
24x36
RIM EL.: 26.85
75 75
90 90 X
24" 75 75
18" INV.: 2.02'
60 60
45 45
30 30
20' WIDE KENT COUNTY
15 0 15
EX.
FP
12
LANDS N/F W X
.
UTILITY EASEMENT .1
0" . . .
CHURCH OF THE HOLY CROSS, DOVER, DELAWARE
S
24x36
EX 18" 24x36
30 X MARK DATE DESCRIPTION
30 T.P.: 2-05-07713-01-5600-00001 EX.
LAYER STATE: C-101
DEED REF.: Q-0020-0165
12
PROJECT NO.: 2019184-07
X
ZONING - IO X X X FP
30 X
DATE: 2020-09-04
24x36 24x36
30 X
EX.
12"
29
R.C
.P.
28 12 X
SCALE: AS SHOWN
27
X
OE 20'
FP DRAWN BY: M.A.R. PROJ. MGR.: M.A.R.
24x36 24x36
X
12
X SHEET
C-101
20' WIDE CITY OF DOVE
R
X
24"
UTILITY EASEMENT
24x36 24x36
X
12
FP
COPYRIGHT 2020
C-101 - Existing Conditions - Skull Property
121
24x36
F:\AutoCAD\Projects\2019\2019184-07\DWG\201918407-Site-C3d18.dwg, Sep 04, 2020 - 12:44pm 24x36
Page 122
24x36 24x36
Item 7.
UE X LEGEND
FP
ITEM EXISTING PROPOSED
24x36 24x36
12
X
SANITARY GRAVITY SEWER LINE, EX. 10"S 10" S
FP SIZE & FLOW DIRECTION
FP
X
SANITARY SEWER FORCE MAIN, SIZE
24x36 24x36
LANDS N/F FP
EX. 10" F.M. 12" F.M.
12 & FLOW DIRECTION FP
18 U.T. RICHARD J. KOSIOR
U.T. & KATHLEEN P. KOSIOR FP
SANITARY SEWER MANHOLE (S.M.H.)
X
T.P.: 2-05-07709-05-7100-00001
DEED REF.: 5045-0067 P LANDS N/F
24x36 LANDS N/F F MICHAEL GRANT SANITARY SEWER CLEANOUT 24x36
MATHEW PERZA ZONING - R8 X
EX. 15"S
T.P.: 2-05-07709-05-7101-00001
& RACHEL GRANT FP EX. 10" W 12" W
12
FP T.P.: 2-05-07709-05-6500-00001 WATER MAIN & SIZE
RCP DEED REF.: 8452-0199
EX. 48" ZONING - R8 DEED REF.: 9012-0298 FP
ZONING - R8 FIRE HYDRANT F.H. F.H.
ARCH I T E C TURE
EX. 6"W
X
24x36 24x36
EX. 15"S LANDS N/F WATER VALVE (W.V.) OR METER (W.M.)
N 78° 25' 47 FP
DENNIS J. GRIMM
T.P.: 2-05-07709-05-6400-00001 FP
W.M. W.V. W.M. W.V. ENG I NE E R I NG
" EEX. 48" RC
X
FCM DEED REF.: 5079-0078 LANDS N/F STORM DRAIN MANHOLE (S.D.M.H.)
PFIP
Dover, DE
N 16° 12'
ZONING - R8 KATHLEEN M. UNTERKOFLER
10" W 75.44'
FP
EX. 15"S
12
T.P.: 2-05-07709-05-6300-00001
24x36
STORM DRAIN LINE (CMP OR RCP)
24x36
X
U.T.
FP
FP
DEED REF.: IS-0026-0405 LANDS N/F
LISA MARIE ROSSI
309 S. Governors Ave.
ZONING - R8
T.P.: 2-05-07709-05-6200-00001 CATCH BASIN Dover, DE 19904
FP 343.96'
EX. 12"S
FP
Ph. 302.734.7950
X
FIR DEED REF.: 7048-0014
FP FP ZONING - R8 UTILITY POLE W/ OVERHEAD SERVICE
24x36
S X
X OR ELECTRIC
(TELEPHONE OR BOTH) FP Fax 302.734.7965 24x36
48.98'
68 V X
26.45'
V X
U.T.
18 17 16 15 10' SIDE YARD SETBACK LINE °0 FP
"S EX. 15
V
FP FP
X X X X
UNDERGROUND ELECTRIC U.E. U.E. Salisbury, MD
14 6' X FP
FH 18 EX
V V
FP X X FP
FP X
. 4 33 FP
FP UNDERGROUND TELEPHONE U.T. U.T. 312 West Main St. Suite 300
24x36
8" "E FP FP 24x36
SCM 12 FP RC FP UNDERGROUND GAS MAIN EX. 2" G 2" G Salisbury, MD 21801
P FP EX. 15"S
X
W.V FP
Ph. 410.546.9100
V V
. FIR FP FP
OE OE PAVEMENT TO BE REMOVED N/A
188
OE OE OE
Fax 410.546.5824
1 OE OE
X
112 OE OE CONCRETE CURB & GUTTER
OE OE OE
Wilmington, NC
24x36 24x36
2 OE OE OE OE OE OE
V
LANDS N/F OE OE
CONCRETE SIDEWALK, SLAB / PAVING
13 MOLLY B. PHILLIPS
APPROXIMATE LOCATION FP
3333 Jaeckle Drive, Suite 120
X
EX. 8"S FP
T.P.: 2-05-07709-05-6100-00001 FP
W.V
. 11 OF 100 YEAR FLOOD PLAIN V 12 DEED REF.: 7372-0173 IMPERVIOUS SURFACED ROAD, DRIVE
Wilmington, North Carolina 28403
W.V W
24" 24" 30" 14 12 7. ZONING - R8 LANDS N/F OR LOT FP
24x36
EX. 8"W
.
13 16 FP Ph. 910.341.7600
.V.
24x36
24" DONALD L. HENRY X
.
15 14 FP ' T.P.: 2-05-07709-05-6000-00001 INDIVIDUAL TREE OR BUSH N/A
UT
W.V
UT 15 FP V DEED REF.: 5775-0149 EVERGREEN DECIDUOUS Fax 910.341.7506
16 36" 16 N 87 ZONING - R8 LANDS N/F X X X
° 59' WIRE FENCE X X X
www.beckermorgan.com
X
GIA DOWNTOWN FP
FP V 32" E PROPERTIES, LLC CHAINLINK FENCE FP
17 18 19
17 V
96"
24x36
19 24x36
FP T.P.: 2-05-07709-05-5901-00001 X STOCKADE FENCE
18 DEED REF.: 8444-0331
OE V
5 FP ZONING - R8
FP STRUCTURE (CONCRETE, WOOD,
19 FP V 152. FP
METAL, ETC.)
24x36
U.T. 09' X FP
24x36
FP N 77° 42' 04"
EX. 12"S
U.T. V
20 20
V E DRAINAGE DITCH OR SWALE
V 50.03' EMBANKMENT SIDESLOPES (DOWN)
RADIUS: 1462.69' 21
ARC LENGTH: 284.55' V S 15° 02' 25" E CONTOUR 49 55
24x36
X 24x36
CHORD BEARING: N 10° 37' 47" W 48" 21 V
V
7.58' FP
22 Xref-Phase-1-Parking-Blk 43.55 FP
.90'
CHORD LENGTH: 284.10'
FP
V ELEVATION SPOT SHOT 25.50 T.C.
25.15
108 47" W 25.00 B.C.
20
23
34'
BENCH MARK
X N/A
18' 18' 24' 18' 52°
24x36 24x36
22
S PROPERTY OR RIGHT-OF-WAY LINE
10
48" 24"
23 X FP
AC
CENTERLINE
FP
24 FP
5' LIGHT POLE FP
24 25
74.9
24x36 24x36
18 9
X
N/A
.85'
CONSTRUCTION NOTE
26
48" 15' REAR YARD FP
183 EX. 18"S
10 1
21 FP
SETBACK LINE
X
27 FP
25 TWO STORY 1 2
S 15° 02' 25" E
24x36
FP 24x36
BRICK 1
BUILDING 13 4 FP X
LANDS N/F
2,743 SQ. FT. 1 5
RADIUS: 1462.69' 1 6 CITY OF DOVER
1 T.P.: 2-05-07713-01-5700-00001
10 17 8
X
24x36
ARC LENGTH: 462.51' 22 24x36
DEED REF.: 5011-0121
CHORD BEARING: N 7° 08' 39" W 26 1 9 FP
1 ZONING - IO
20 1
CHORD LENGTH: 460.59' 48" FP X
FP
2 2
PROPOSED 2 LANDS N/F
24x36
AC
APPROXIMATE LOCATION 24x36
"S
CONCRETE CURB (typ.) 23
X
70.00'
.
EX. 12 23 60" 24 OF 100 YEAR FLOOD PLAIN CITY OF DOVER
ONE STORY
27 FRAME
25 T.P.: 2-05-07713-01-5000-00001
BUILDING
26 N 74° 57' 34" E FP
X
DEED REF.: T-0036-0203 N
24x36
28 1,112 SQ. FT.
27 170.01' FP ZONING - IO 24x36
71.52'
10 34 98.49'
S 15° 02' 25" E
X
V
28
24 10 FP
V X
FP
24x36 24x36
V
24"
PHASE 1 PARKING ADDITION 28 FP
PROPOSED PARKING PROPERTY LINE TO BE V X
29
139,815 S.F. / 15,535 S.Y. LIGHT FIXTURE (typ.) EXTINGUISHED PER THE V
FP
FP
CONSOLIDATION PLAN V
24x36 24x36
X
25 29
60"
25 30"
9'
26 18' FP
20' FRONT YARD
X
30'
SETBACK LINE
27
36OE 30 21 9
80.00'
24x36 24x36
30" OE OE OE PROJECT TITLE
36"
X X X 10 X
11
BAYHEALTH
28
24"
18' 265 12
30" 31 ONE STORY 2 4 13 S8
RADIUS: 1462.69' 2 14 X7° 2
POLE 9' 2
294 197 MEDICAL
29
245
24x36 24x36
X
ARC LENGTH: 177.96' 26
31 BUILDING 15 2" E
CHORD BEARING: N 1° 34' 16" W 1,440 SQ. FT.
26
2 16 N 73° 01' 53" E X
24' 17 28.34' X 78.4
EET
CHORD LENGTH: 177.86' EXISTING ASPHALT 18 8'
CENTER, INC
X
30" PARKING AREA
15 19
40' 20 S
10 74
24x36 24x36
30 21 X
18' 22 °5
0'
X
SCULL PROPERTY
23 5
.
W.V
24' 8"
STR 38 34 6 "S
.
W.M 31 X.
X E
SITE DEVELOPMENT
E
24
24x36 24x36
18' TWO STORY 26
X
20
MASTER PLAN
KCR OT W
FRAME BUILDING 25 X
EX. 6"S
1,044 SQ. FT.
X FP
PROPOSED PROPOSED 24 3
TE
25
BAYHEALTH STAFF
24x36
2 FP
24x36
24'
25, IDE R
X
32 CONCRETE CURB (typ.) EX. 6"S CONCRETE CURB (typ.) 23 4
30 29 2
PARKING LOT
X
31
24'
32 28 EX. SIGN 25 X
STA MIN IG
9' 27 FP FP
12" STEEL - MD - 7.13'
26 EXPANSION
27
18'
OR HT O
24x36 24x36
X
EX. 30" F.M.
26
4" PVC - MD - 2.01'
FP
42 34 26
X 18
3.8 605 S. STATE STREET
8
ART F W
FP
8" PVC - MD - 5.55'
8" PVC - MD - 5.84'
X
18' 4" PVC - MD - 1.66'
4" PVC - MD - 1.70'
4" PVC - MD - 2.34'
SHED ' FP CITY OF DOVER
X
24x36 24x36
8" PVC - MD - 3.84'
9 KENT COUNTY, DELAWARE
A
8" PVC - MD - 3.53'
SOU ERI
30" 33 FP
AL Y
28
FP
TWO STORY
X
SHEET TITLE
12"S 24' PROPOSED
STUCCOPARKING
TH
BUILDING
34
S 34
LIGHT FIXTURE (typ.)
SITE PLAN
24x36 24x36
2,100 SQ. FT. G.M.
EX. X
60 ° 35
FO 17 PHASE 1
EX. 10" WATER
26 FP X
EXISTING ONE-STORY EX. 18"S ' 27"
24x36 24x36
44
.P.
32 COVERED
BRICK BUILDING
R.C 33
.88' ENTRANCE X
E
TOTAL PARKING
24"
31 OUTPATIENT SURGERY CENTER
184 17
EX.
24x36 30 10,800 S.F. ± - FOOTPRINT FP X 24x36
15' REAR YARD
SPACES: 517
26
27"
PHASE 1 EXISTING PARKING
29
PROPOSED 28 27 26 SETBACK LINE X
EXISTING ASPHALT
ACCESSIBLE RAMP (typ.) TO BE PARKING
REPAVED AREA
14 ACCESSIBLE PARKING SPACES (2 VAN) 36,261 S.F. / 4,029 S.Y.
GEN
24x36 24x36
28
X
W.V.
FP
W.M.
W.M.
17 27 X
24x36 32 32 32 10 9 24x36
27
AC
33 60" 33 X
29
32 W.V.
AC
FP 0 20 40 80
EX. 8" W
28
3
W.V. X
PROPOSED 31 ONE STORY
24x36
LIGHT POLE 27 D. 24x36
17 FRAME
30
30 CONCRETE SIDEWALK (typ.)
176
E 29
31 BUILDING Do Not Explode - Select Scale
SCALE: 1" = 40'
X
34" 28 5,044 SQ. FT.
F.H. .50'
W.V.
FP
32 AC
26
24x36
34' X 24x36
27 F.M.
EX. 10" W
33 27 EXISTING ISSUE BLOCK
N 1°
SCULL TERRACE
EXISTING ASPHALT CONCRETE CURB 30"
34
EX. 24" R.C.P. X
33 32 PARKING AREA
EX.
26 N 78° 28' 32
"E
X
E
10' SIDE YARD FLOODPLAIN LINE FP X
UTILITY POLE (typ.) EXISTING
24x36 24x36
25.33'
WHEELCHAIR RAMP 37.87'
OE SETBACK LINE
OE OE OE 12 26 18 23
S 11° 54' 41"
OE
W.M
. .
F.H OE OE
OE 121.55'
24x36 24x36
FCM FCM
.
W.V
18" FP
24"
.
W.V
.
W.V 1115.96' 12 12 12 12 12 12 12
S 72° 59' 55" W
10"S
X
29
.P.
15 0 15
R.C
30 30
24x36
EX. 60
75
90
45 45
60
75
90 X
24x36
24" 75
60
75
60
45 45
30 30
20' WIDE KENT COUNTY
15 0 15
EX.
FP
12
LANDS N/F W X
.
UTILITY EASEMENT .1
0" . . .
CHURCH OF THE HOLY CROSS, DOVER, DELAWARE
S
24x36
EX 18" 24x36
30 X MARK DATE DESCRIPTION
30 T.P.: 2-05-07713-01-5600-00001 EX.
LAYER STATE: C-201
DEED REF.: Q-0020-0165
12
PROJECT NO.: 2019184-07
X
ZONING - IO X X X FP
30 X
DATE: 2020-09-04
24x36 24x36
30 X
EX.
12"
29
R.C
.P.
28 12 X
SCALE: AS SHOWN
27
X
OE 20'
FP DRAWN BY: M.A.R. PROJ. MGR.: M.A.R.
24x36 24x36
X
12
X SHEET
C-201
20' WIDE CITY OF DOVE
R
X
24"
UTILITY EASEMENT
24x36 24x36
X
12
FP
COPYRIGHT 2020
C-201 - BayHealth Scull Property - Phase 1
122
24x36
F:\AutoCAD\Projects\2019\2019184-07\DWG\201918407-Site-C3d18.dwg, Sep 04, 2020 - 12:26pm 24x36
Page 123
24x36 24x36
Item 7.
UE X LEGEND
FP
ITEM EXISTING PROPOSED
24x36 24x36
12
X
SANITARY GRAVITY SEWER LINE, EX. 10"S 10" S
FP SIZE & FLOW DIRECTION
FP
X
SANITARY SEWER FORCE MAIN, SIZE
24x36 24x36
LANDS N/F FP
EX. 10" F.M. 12" F.M.
12 & FLOW DIRECTION FP
18 U.T. RICHARD J. KOSIOR
U.T. & KATHLEEN P. KOSIOR FP
SANITARY SEWER MANHOLE (S.M.H.)
X
T.P.: 2-05-07709-05-7100-00001
DEED REF.: 5045-0067 P LANDS N/F
24x36 LANDS N/F F MICHAEL GRANT SANITARY SEWER CLEANOUT 24x36
MATHEW PERZA ZONING - R8 X
EX. 15"S
T.P.: 2-05-07709-05-7101-00001
& RACHEL GRANT FP EX. 10" W 12" W
12
FP T.P.: 2-05-07709-05-6500-00001 WATER MAIN & SIZE
RCP DEED REF.: 8452-0199
EX. 48" ZONING - R8 DEED REF.: 9012-0298 FP
ZONING - R8 FIRE HYDRANT F.H. F.H.
ARCH I T E C TURE
EX. 6"W
X
24x36 24x36
EX. 15"S LANDS N/F WATER VALVE (W.V.) OR METER (W.M.)
N 78° 25' 47 FP
DENNIS J. GRIMM
T.P.: 2-05-07709-05-6400-00001 FP
W.M. W.V. W.M. W.V. ENG I NE E R I NG
" EEX. 48" RC
X
FCM DEED REF.: 5079-0078 LANDS N/F STORM DRAIN MANHOLE (S.D.M.H.)
PFIP
Dover, DE
N 16° 12'
ZONING - R8 KATHLEEN M. UNTERKOFLER
10" W 75.44'
FP
EX. 15"S
12
T.P.: 2-05-07709-05-6300-00001
24x36
STORM DRAIN LINE (CMP OR RCP)
24x36
X
U.T.
FP
FP
DEED REF.: IS-0026-0405 LANDS N/F
LISA MARIE ROSSI
309 S. Governors Ave.
ZONING - R8
T.P.: 2-05-07709-05-6200-00001 CATCH BASIN Dover, DE 19904
FP 343.96'
EX. 12"S
FP
Ph. 302.734.7950
X
FIR DEED REF.: 7048-0014
FP FP ZONING - R8 UTILITY POLE W/ OVERHEAD SERVICE
24x36
S X
X OR ELECTRIC
(TELEPHONE OR BOTH) FP Fax 302.734.7965 24x36
48.98'
68 V X
26.45'
V X
U.T.
18 17 16 15 10' SIDE YARD SETBACK LINE °0 FP
"S EX. 15
V
FP FP
X X X X
UNDERGROUND ELECTRIC U.E. U.E. Salisbury, MD
14 6' X FP
FH 18 EX
V V
FP X X FP
FP X
. 4 33 FP
FP UNDERGROUND TELEPHONE U.T. U.T. 312 West Main St. Suite 300
24x36
8" "E FP FP 24x36
SCM 12 FP RC FP UNDERGROUND GAS MAIN EX. 2" G 2" G Salisbury, MD 21801
P FP EX. 15"S
X
W.V FP
Ph. 410.546.9100
V V
. FIR FP FP
OE OE PAVEMENT TO BE REMOVED N/A
188
OE OE OE
Fax 410.546.5824
1 OE OE
X
112 OE OE CONCRETE CURB & GUTTER
OE OE OE
Wilmington, NC
24x36 24x36
2 OE OE OE OE OE OE
V
LANDS N/F OE OE
CONCRETE SIDEWALK, SLAB / PAVING
13 MOLLY B. PHILLIPS
APPROXIMATE LOCATION FP
3333 Jaeckle Drive, Suite 120
X
EX. 8"S FP
T.P.: 2-05-07709-05-6100-00001 FP
W.V
. 11 OF 100 YEAR FLOOD PLAIN V 12 DEED REF.: 7372-0173 IMPERVIOUS SURFACED ROAD, DRIVE
Wilmington, North Carolina 28403
W.V W
24" 24" 30" 14 12 7. ZONING - R8 LANDS N/F OR LOT FP
24x36
EX. 8"W
.
13 16 FP Ph. 910.341.7600
.V.
24x36
24" DONALD L. HENRY X
.
15 14 FP ' T.P.: 2-05-07709-05-6000-00001 INDIVIDUAL TREE OR BUSH N/A
UT
W.V
UT 15 FP V DEED REF.: 5775-0149 EVERGREEN DECIDUOUS Fax 910.341.7506
16 36" 16 N 87 ZONING - R8 LANDS N/F X X X
° 59' WIRE FENCE X X X
www.beckermorgan.com
X
GIA DOWNTOWN FP
FP V 32" E PROPERTIES, LLC CHAINLINK FENCE FP
17 18 19
17 V
96"
24x36
19 24x36
FP T.P.: 2-05-07709-05-5901-00001 X STOCKADE FENCE
18 DEED REF.: 8444-0331
OE V
5 FP ZONING - R8
FP STRUCTURE (CONCRETE, WOOD,
19 FP V 152. FP
METAL, ETC.)
24x36
U.T. 09' X FP
24x36
FP N 77° 42' 04"
EX. 12"S
U.T. V
20 20
V E DRAINAGE DITCH OR SWALE
V 50.03' EMBANKMENT SIDESLOPES (DOWN)
RADIUS: 1462.69' 21
ARC LENGTH: 284.55' V S 15° 02' 25" E CONTOUR 49 55
24x36
X 24x36
CHORD BEARING: N 10° 37' 47" W 48" 21 V
V
7.58' FP
22 Xref-Phase-1-Parking-Blk 43.55 FP
.90'
CHORD LENGTH: 284.10'
FP
V ELEVATION SPOT SHOT 25.50 T.C.
25.15
108 47" W
20 Xref-Phase-2-Parking-Blk 25.00 B.C.
23
34'
BENCH MARK
X N/A
18' 18' 24' 18' 52°
24x36 24x36
22
S PROPERTY OR RIGHT-OF-WAY LINE
10
48" 24"
23 X FP
AC
CENTERLINE
FP
24 FP
5' LIGHT POLE FP
24 25
74.9
24x36 24x36
18 9
X
N/A
.85'
CONSTRUCTION NOTE
26
48" 15' REAR YARD FP
183 EX. 18"S
10 1
21 FP
SETBACK LINE
X
27 FP
25 TWO STORY 1 2
S 15° 02' 25" E
24x36
FP 24x36
BRICK 1
BUILDING 13 4 FP X
LANDS N/F
2,743 SQ. FT. 1 5
RADIUS: 1462.69' 1 6 CITY OF DOVER
1 T.P.: 2-05-07713-01-5700-00001
10 17 8
X
24x36
ARC LENGTH: 462.51' 22 24x36
DEED REF.: 5011-0121
CHORD BEARING: N 7° 08' 39" W 26 1 9 FP
1 ZONING - IO
20 1
CHORD LENGTH: 460.59' 48" FP X
FP
2 2
PROPOSED 2 LANDS N/F
24x36
AC
APPROXIMATE LOCATION 24x36
"S
CONCRETE CURB (typ.) 23
X
70.00'
.
EX. 12 23 60" 24 OF 100 YEAR FLOOD PLAIN CITY OF DOVER
ONE STORY
27 FRAME
25 T.P.: 2-05-07713-01-5000-00001
BUILDING
26 N 74° 57' 34" E FP
X
DEED REF.: T-0036-0203 N
24x36
28 1,112 SQ. FT.
27 170.01' FP ZONING - IO 24x36
71.52'
10 34 98.49'
S 15° 02' 25" E
X
V
28
24 10 FP
V X
FP
24x36 24x36
V
24"
PHASE 1 PARKING ADDITION 28 FP
PROPOSED PARKING PROPERTY LINE TO BE V X
29
139,815 S.F. / 15,535 S.Y. LIGHT FIXTURE (typ.) EXTINGUISHED PER THE V
FP
FP
CONSOLIDATION PLAN V
24x36 24x36
X
25 29
60"
25 30"
9'
26 18' FP
20' FRONT YARD
X
30'
SETBACK LINE
27
36OE 30 21 9
80.00'
24x36 24x36
30" OE OE OE PROJECT TITLE
36"
X X X 10 X
11
BAYHEALTH
28
24"
18' 265 12
30" 31 ONE STORY 2 4 13 S8
RADIUS: 1462.69' 2 14 X 7° 2
POLE 9' 2
294 197 MEDICAL
29
245
24x36 24x36
X
ARC LENGTH: 177.96' 26
31 BUILDING 15 2" E
CHORD BEARING: N 1° 34' 16" W 1,440 SQ. FT.
26
2 16 N 73° 01' 53" E X
24' 17 28.34' X 78.4
EET
CHORD LENGTH: 177.86' EXISTING ASPHALT 18 8'
CENTER, INC
X
30" PARKING AREA
15 19
40' 20 S
10 74
24x36 24x36
30 21 X
18' 22 °5
0'
X
SCULL PROPERTY
23 5
.
W.V
24' 8"
STR 38 34 6 "S
.
W.M 31 X.
X E
SITE DEVELOPMENT
E
24
24x36 24x36
18' TWO STORY 26
X
20
MASTER PLAN
KCR OT W
FRAME BUILDING 25 X
EX. 6"S
1,044 SQ. FT.
X FP
PROPOSED PROPOSED 24 3
TE
25
BAYHEALTH STAFF
24x36
2 FP
24x36
24'
25, IDE R
X
32 CONCRETE CURB (typ.) EX. 6"S CONCRETE CURB (typ.) 23 4
30 29 2
PARKING LOT
X
31
24'
32 28 EX. SIGN 25 X
STA MIN IG
9' 27 FP FP
12" STEEL - MD - 7.13'
26 EXPANSION
27
18'
OR HT O
24x36 24x36
X
EX. 30" F.M.
26
4" PVC - MD - 2.01'
FP
42 34 26
X 18
3.8 605 S. STATE STREET
9' 8
ART F W
FP
8" PVC - MD - 5.55'
8" PVC - MD - 5.84'
X
24x36
18' 4" PVC - MD - 1.66'
4" PVC - MD - 1.70'
4" PVC - MD - 2.34'
8" PVC - MD - 3.84'
13 SHED 18' '
X
FP CITY OF DOVER 24x36
9 KENT COUNTY, DELAWARE
A
8" PVC - MD - 3.53'
SOU ERI
30" 33 FP
AL Y
28
FP
PROPOSED PARKING SHEET TITLE
X
TWO STORY
12"S 24' PROPOSED
STUCCOPARKING 27'
TH
BUILDING LIGHT FIXTURE (typ.)
34
S 34
LIGHT FIXTURE (typ.)
SITE PLAN
24x36 24x36
2,100 SQ. FT. G.M.
EX. X
60 ° 35
FO 17 PHASE 2
EX. 10" WATER
26 FP X
' 27"
18'
EXISTING ONE-STORY EX. 18"S
24x36 24x36
44 26
.P.
32 COVERED
BRICK BUILDING
R.C 33
.88' ENTRANCE X
E
TOTAL PARKING
24"
31 OUTPATIENT SURGERY CENTER 18'
184 17
EX.
24x36 30 10,800 S.F. ± - FOOTPRINT FP X 24x36
15' REAR YARD
SPACES: 589
26
27"
PHASE 1 EXISTING PARKING PHASE 2 PARKING ADDITION
29
PROPOSED 28 27 SETBACK LINE X
EXISTING ASPHALT
26 27'
ACCESSIBLE RAMP (typ.) TO BE PARKING
REPAVED AREA 31,975 S.F. / 3,553 S.Y.
14 ACCESSIBLE PARKING SPACES (2 VAN) 36,261 S.F. / 4,029 S.Y.
GEN
24x36 24x36
28
X
W.V.
FP
W.M.
W.M.
17 27
13 18'
X
24x36 32 32 32 10 9 24x36
27
AC
33 60" 33 X
29
32 W.V. 15' AC
FP 0 20 40 80
EX. 8" W
28 W.V. X
PROPOSED 31 ONE STORY
LIGHT POLE 27 D.
9'
24x36
13
24x36
17 FRAME
30
30 CONCRETE SIDEWALK (typ.) 18' 176
E 29
31 BUILDING Do Not Explode - Select Scale
SCALE: 1" = 40'
X
34" 28 5,044 SQ. FT.
F.H. .50'
W.V.
FP
32 AC
98
24x36
34' PROPOSED
X 24x36
27 F.M.
EX. 10" W
33 27 EXISTING
CONCRETE CURB (typ.) ISSUE BLOCK
SCULL TERRACE
N 1° EXISTING ASPHALT CONCRETE CURB 30" 32'
34
EX. 24" R.C.P. X
33 32 PARKING AREA
EX.
26 N 78° 28' 32
"E
X
E
10' SIDE YARD FLOODPLAIN LINE FP X
UTILITY POLE (typ.) EXISTING
24x36 24x36
25.33'
WHEELCHAIR RAMP 37.87'
OE SETBACK LINE
OE OE OE 12 26 18 20 13 18'
S 11° 54' 41"
OE
W.M
. .
F.H OE OE
OE 121.55'
24x36 24x36
FCM FCM
.
W.V
18" FP
24"
.
W.V
.
W.V 1115.96' 12 12 12 12 12 12 12
S 72° 59' 55" W
10"S
X
29
.P.
15 0 15
R.C
30 30
24x36
EX. 60
75
90
45 45
60
75
90 X
24x36
24" 75
60
75
60
45 45
30 30
20' WIDE KENT COUNTY
15 0 15
EX.
FP
12
LANDS N/F W X
.
UTILITY EASEMENT .1
0" . . .
CHURCH OF THE HOLY CROSS, DOVER, DELAWARE
S
24x36
EX 18" 24x36
30 X MARK DATE DESCRIPTION
30 T.P.: 2-05-07713-01-5600-00001 EX.
LAYER STATE: C-202
DEED REF.: Q-0020-0165
12
PROJECT NO.: 2019184-07
X
ZONING - IO X X X FP
30 X
DATE: 2020-09-04
24x36 24x36
30 X
EX.
12"
29
R.C
.P.
28 12 X
SCALE: AS SHOWN
27
X
OE 20'
FP DRAWN BY: M.A.R. PROJ. MGR.: M.A.R.
24x36 24x36
X
12
X SHEET
C-202
20' WIDE CITY OF DOVE
R
X
24"
UTILITY EASEMENT
24x36 24x36
X
12
FP
COPYRIGHT 2020
C-202 - BayHealth Scull Property - Phase 2
123
24x36
F:\AutoCAD\Projects\2019\2019184-07\DWG\201918407-Site-C3d18.dwg, Sep 04, 2020 - 12:26pm 24x36
Page 124
24x36 24x36
Item 7.
UE X LEGEND
FP
ITEM EXISTING PROPOSED
24x36 24x36
12
X
SANITARY GRAVITY SEWER LINE, EX. 10"S 10" S
FP SIZE & FLOW DIRECTION
FP
X
SANITARY SEWER FORCE MAIN, SIZE
24x36 24x36
LANDS N/F FP
EX. 10" F.M. 12" F.M.
12 & FLOW DIRECTION FP
18 U.T. RICHARD J. KOSIOR
U.T. & KATHLEEN P. KOSIOR FP
SANITARY SEWER MANHOLE (S.M.H.)
X
T.P.: 2-05-07709-05-7100-00001
DEED REF.: 5045-0067 P LANDS N/F
24x36 LANDS N/F F MICHAEL GRANT SANITARY SEWER CLEANOUT 24x36
MATHEW PERZA ZONING - R8 X
EX. 15"S
T.P.: 2-05-07709-05-7101-00001
& RACHEL GRANT FP EX. 10" W 12" W
12
FP T.P.: 2-05-07709-05-6500-00001 WATER MAIN & SIZE
RCP DEED REF.: 8452-0199
EX. 48" ZONING - R8 DEED REF.: 9012-0298 FP
ZONING - R8 FIRE HYDRANT F.H. F.H.
ARCH I T E C TURE
EX. 6"W
X
24x36 24x36
EX. 15"S LANDS N/F WATER VALVE (W.V.) OR METER (W.M.)
N 78° 25' 47 FP
DENNIS J. GRIMM
T.P.: 2-05-07709-05-6400-00001 FP
W.M. W.V. W.M. W.V. ENG I NE E R I NG
" EEX. 48" RC
X
FCM DEED REF.: 5079-0078 LANDS N/F STORM DRAIN MANHOLE (S.D.M.H.)
PFIP
Dover, DE
N 16° 12'
ZONING - R8 KATHLEEN M. UNTERKOFLER
10" W 75.44'
FP
EX. 15"S
12
T.P.: 2-05-07709-05-6300-00001
24x36
STORM DRAIN LINE (CMP OR RCP)
24x36
X
U.T.
FP
FP
DEED REF.: IS-0026-0405 LANDS N/F
LISA MARIE ROSSI
309 S. Governors Ave.
ZONING - R8
T.P.: 2-05-07709-05-6200-00001 CATCH BASIN Dover, DE 19904
FP 343.96'
EX. 12"S
FP
Ph. 302.734.7950
X
FIR DEED REF.: 7048-0014
FP FP ZONING - R8 UTILITY POLE W/ OVERHEAD SERVICE
24x36
S X
X OR ELECTRIC
(TELEPHONE OR BOTH) FP Fax 302.734.7965 24x36
48.98'
68 V X
26.45'
V X
U.T.
18 17 16 15 10' SIDE YARD SETBACK LINE °0 FP
"S EX. 15
V
FP FP
X X X X
UNDERGROUND ELECTRIC U.E. U.E. Salisbury, MD
14 6' X FP
FH 18 EX
V V
FP X X FP
FP X
. 4 33 FP
FP UNDERGROUND TELEPHONE U.T. U.T. 312 West Main St. Suite 300
24x36
8" "E FP FP 24x36
SCM 12 FP RC FP UNDERGROUND GAS MAIN EX. 2" G 2" G Salisbury, MD 21801
P FP EX. 15"S
X
W.V FP
Ph. 410.546.9100
V V
. FIR FP FP
OE OE PAVEMENT TO BE REMOVED N/A
188
OE OE OE
Fax 410.546.5824
1 OE OE
X
112 OE OE CONCRETE CURB & GUTTER
OE OE OE
Wilmington, NC
24x36 24x36
2 OE OE OE OE OE OE
V
LANDS N/F OE OE
PHASE 3 ENTRANCE
CONCRETE SIDEWALK, SLAB / PAVING
13 MOLLY B. PHILLIPS
APPROXIMATE LOCATION FP
3333 Jaeckle Drive, Suite 120
X
EX. 8"S FP FP
W.V 38' 11 12
T.P.: 2-05-07709-05-6100-00001
. 12,195 S.F.
24" / 1,355 S.Y. OF 100 YEAR FLOOD PLAIN V
7.
DEED REF.: 7372-0173 IMPERVIOUS SURFACED ROAD, DRIVE
Wilmington, North Carolina 28403
W.V W
24" 30" 14 12 ZONING - R8 LANDS N/F OR LOT FP
24x36
EX. 8"W
.
13 16 FP Ph. 910.341.7600
.V.
24x36
24" DONALD L. HENRY X
.
15 14 FP ' T.P.: 2-05-07709-05-6000-00001 INDIVIDUAL TREE OR BUSH N/A
UT
W.V
UT 15 FP V DEED REF.: 5775-0149 EVERGREEN DECIDUOUS Fax 910.341.7506
16 36" 16 N 87 ZONING - R8 LANDS N/F X X X
° 59' WIRE FENCE X X X
www.beckermorgan.com
X
GIA DOWNTOWN FP
FP V 32" E PROPERTIES, LLC CHAINLINK FENCE FP
17 18 19
17 V
96"
24x36
19 24x36
FP T.P.: 2-05-07709-05-5901-00001 X STOCKADE FENCE
18 DEED REF.: 8444-0331
OE V
5 FP ZONING - R8
FP STRUCTURE (CONCRETE, WOOD,
19 FP V 152. FP
METAL, ETC.)
24x36
U.T. 09' X FP
24x36
FP N 77° 42' 04"
EX. 12"S
U.T. V
20 20
V E DRAINAGE DITCH OR SWALE
V 50.03' EMBANKMENT SIDESLOPES (DOWN)
RADIUS: 1462.69' 21
ARC LENGTH: 284.55' V S 15° 02' 25" E CONTOUR 49 55
24x36
X 24x36
CHORD BEARING: N 10° 37' 47" W 48" 21 V
V
7.58' FP
22 Xref-Phase-1-Parking-Blk 43.55 FP
.90'
CHORD LENGTH: 284.10'
FP
V ELEVATION SPOT SHOT 25.50 T.C.
25.15
108 47" W
20 Xref-Phase-2-Parking-Blk 25.00 B.C.
23 Xref-Phase-3-Parking-Blk
34'
BENCH MARK
X N/A
18' 18' 24' 18' 52°
24x36 24x36
22
S PROPERTY OR RIGHT-OF-WAY LINE
10
48" 24"
23 X FP
AC
CENTERLINE
FP
24 FP
5' LIGHT POLE FP
24 25
74.9
24x36 24x36
18 9
X
N/A
.85'
CONSTRUCTION NOTE
26
48" 15' REAR YARD FP
183 EX. 18"S
10 1
21 FP
SETBACK LINE
X
27 FP
25 TWO STORY 1 2
S 15° 02' 25" E
24x36
FP 24x36
BRICK 1
BUILDING 13 4 FP X
LANDS N/F
2,743 SQ. FT. 1 5
RADIUS: 1462.69' 1 6 CITY OF DOVER
1 T.P.: 2-05-07713-01-5700-00001
10
6 17 8
X
24x36
ARC LENGTH: 462.51' 22 24x36
DEED REF.: 5011-0121
CHORD BEARING: N 7° 08' 39" W 26 1 9 FP
1 ZONING - IO
20 1
CHORD LENGTH: 460.59' 48" FP X
FP
2 2
PROPOSED 2 LANDS N/F
24x36
AC
APPROXIMATE LOCATION 24x36
"S
CONCRETE CURB (typ.) 23
X
70.00'
.
EX. 12 23 60" 24 OF 100 YEAR FLOOD PLAIN CITY OF DOVER
ONE STORY
27 FRAME
25 T.P.: 2-05-07713-01-5000-00001
BUILDING
26 N 74° 57' 34" E FP
X
DEED REF.: T-0036-0203 N
24x36
28 1,112 SQ. FT.
27 170.01' FP ZONING - IO 24x36
71.52'
10 34 98.49'
S 15° 02' 25" E
X
V
28
24 10 FP
V X
FP
24x36 24x36
V
24"
PHASE 1 PARKING ADDITION 28 FP
PROPOSED PARKING PROPERTY LINE TO BE V X
29
139,815 S.F. / 15,535 S.Y. LIGHT FIXTURE (typ.) EXTINGUISHED PER THE V
FP
FP
CONSOLIDATION PLAN V
24x36 24x36
X
25 29
60"
25 30"
9'
26 18' FP
20' FRONT YARD
X
30'
SETBACK LINE
27
36OE 30 21 9
80.00'
24x36 24x36
30" OE OE OE PROJECT TITLE
36"
X X X 10 X
11
BAYHEALTH
28
24"
18' 265 12
30" 31 ONE STORY 2 4 13 S8
RADIUS: 1462.69' 2 14 X 7° 2
POLE 9' 2
290
294 197 MEDICAL
29
245
24x36 24x36
X
ARC LENGTH: 177.96' 26
31 BUILDING 15 2" E
CHORD BEARING: N 1° 34' 16" W 1,440 SQ. FT.
26
2 16 N 73° 01' 53" E X
24' 17 28.34' X 78.4
EET
CHORD LENGTH: 177.86' EXISTING ASPHALT 18 8'
CENTER, INC
X
30" PARKING AREA
15 19
40' 20 S
10 74
24x36 24x36
30 21 X
18' 22 °5
0'
X
SCULL PROPERTY
23 5
.
W.V
24' 8"
STR 38 34 6 "S
.
W.M 31 X.
X E
SITE DEVELOPMENT
E
24
24x36 24x36
18' TWO STORY 26
X
20
MASTER PLAN
KCR OT W
FRAME BUILDING 25 X
EX. 6"S
1,044 SQ. FT.
X FP
PROPOSED PROPOSED 24 3
TE
25
BAYHEALTH STAFF
24x36
2 FP
24x36
24'
25, IDE R
X
32 CONCRETE CURB (typ.) EX. 6"S CONCRETE CURB (typ.) 23 4
30 29 2
PARKING LOT
X
31
24'
32 28 EX. SIGN 25 X
STA MIN IG
9' 27 FP FP
12" STEEL - MD - 7.13'
26 EXPANSION
27
18'
OR HT O
24x36 24x36
X
EX. 30" F.M.
26
4" PVC - MD - 2.01'
FP
42 34 26
X 18
3.8 605 S. STATE STREET
9' 9' 8
ART F W
FP
8" PVC - MD - 5.55'
8" PVC - MD - 5.84'
X
24x36
18' 4" PVC - MD - 1.66'
4" PVC - MD - 1.70'
19 4" PVC - MD - 2.34'
8" PVC - MD - 3.84'
18' 13 SHED 18' '
X
FP CITY OF DOVER 24x36
9 KENT COUNTY, DELAWARE
A
8" PVC - MD - 3.53'
SOU ERI
30" 33 FP
AL Y
28
FP
PROPOSED PARKING SHEET TITLE
PHASE 3 PARKING ADDITION
X
TWO STORY
12"S 24' PROPOSED
STUCCOPARKING 27' 27'
TH
BUILDING LIGHT FIXTURE (typ.)
34
S 34
SITE PLAN
LIGHT FIXTURE (typ.) 30,780 S.F. / 3,420 S.Y.
24x36 24x36
2,100 SQ. FT. G.M.
EX. X
60 ° 35
FO 17 PHASE 3
EX. 10" WATER
26 FP X
' 27"
18' 18'
EXISTING ONE-STORY EX. 18"S
24x36 24x36
44 38 26
.P.
32 COVERED
BRICK BUILDING
R.C 33
.88' ENTRANCE X
E
TOTAL PARKING
24"
31 OUTPATIENT SURGERY CENTER 18' 18'
184 17
EX.
24x36 30 10,800 S.F. ± - FOOTPRINT FP X 24x36
15' REAR YARD
SPACES: 680
26
193
27"
PHASE 1 EXISTING PARKING PHASE 2 PARKING ADDITION
29
PROPOSED 28 27 SETBACK LINE X
EXISTING ASPHALT
26 PROPOSED 27' 27'
ACCESSIBLE RAMP (typ.) TO BE PARKING
REPAVED 31,975 S.F. / 3,553 S.Y.
14 ACCESSIBLE PARKING SPACES (2 VAN)
AREA
CONCRETE CURB (typ.) GEN
36,261 S.F. / 4,029 S.Y.
24x36 24x36
28
X
W.V.
FP
W.M.
W.M.
17 27
19 18' 13 18'
X
24x36 32 32 32 10 9 24x36
27
AC
33 60" 33 X
29
32 15' W.V. 15' AC
FP 0 20 40 80
EX. 8" W
28 W.V. X
PROPOSED 31 ONE STORY
LIGHT POLE
9' 27 D.
9'
24x36
19 13
24x36
17 FRAME
30
30 CONCRETE SIDEWALK (typ.) 18' 18' 176
E 29
31 BUILDING Do Not Explode - Select Scale
SCALE: 1" = 40'
X
34" 28 5,044 SQ. FT.
F.H. .50'
W.V.
FP
32
PROPOSED PARKING
AC
98
24x36
34' PROPOSED
X 24x36
27
32'.M.
EX. 10" W
33 27 LIGHT FIXTURE
EXISTING (typ.) CONCRETE CURB (typ.) ISSUE BLOCK
SCULL TERRACE
32'
F
N 1° EXISTING ASPHALT CONCRETE CURB 30"
34
EX. 24" R.C.P. X
33 32 PARKING AREA
EX.
26 N 78° 28' 32
"E
X
E
10' SIDE YARD FLOODPLAIN LINE FP X
UTILITY POLE (typ.) EXISTING
24x36 24x36
25.33'
WHEELCHAIR RAMP 37.87'
OE SETBACK LINE
OE OE OE 12 26 18 2020 18' 13 18'
S 11° 54' 41"
OE
W.M
. .
F.H OE OE
OE 121.55'
24x36 24x36
FCM FCM
.
W.V
18" FP
24"
.
W.V
.
W.V 1115.96' 12 12 12 12 12 12 12
S 72° 59' 55" W
10"S
X
29
.P.
15 0 15
R.C
30 30
24x36
EX. 60
75
90
45 45
60
75
90 X
24x36
24" 75
60
75
60
45 45
30 30
20' WIDE KENT COUNTY
15 0 15
EX.
FP
12
LANDS N/F W X
.
UTILITY EASEMENT .1
0" . . .
CHURCH OF THE HOLY CROSS, DOVER, DELAWARE
S
24x36
EX 18" 24x36
30 X MARK DATE DESCRIPTION
30 T.P.: 2-05-07713-01-5600-00001 EX.
LAYER STATE: C-203
DEED REF.: Q-0020-0165
12
PROJECT NO.: 2019184-07
X
ZONING - IO X X X FP
30 X
DATE: 2020-09-04
24x36 24x36
30 X
EX.
12"
29
R.C
.P.
28 12 X
SCALE: AS SHOWN
27
X
OE 20'
FP DRAWN BY: M.A.R. PROJ. MGR.: M.A.R.
24x36 24x36
X
12
X SHEET
C-203
20' WIDE CITY OF DOVE
R
X
24"
UTILITY EASEMENT
24x36 24x36
X
12
FP
COPYRIGHT 2020
C-203 - BayHealth Scull Property - Phase 3
124
24x36
F:\AutoCAD\Projects\2019\2019184-07\DWG\201918407-Site-C3d18.dwg, Sep 04, 2020 - 12:27pm 24x36
Page 125
FP Item 7.
ZONING - R8 FP
LANDS N/F
DENNIS J. GRIMM
T.P.: 2-05-07709-05-6400-00001
FCM EX. 48" RC FP DEED REF.: 5079-0078
PFIP LANDS N/F
ZONING - R8 KATHLEEN M. UNTERKOFLER
T.P.: 2-05-07709-05-6300-00001
FP LANDS N/F
ET
DEED REF.: IS-0026-0405
FP ZONING - R8 LISA MARIE ROSSI
TRE
R S
FP
T.P.: 2-05-07709-05-6200-00001
E
WAT
FP
FP FIR FP DEED REF.: 7048-0014
ZONING - R8
18 17 FP V V
16 15 V FP FP
18 14 V FP
EX FP FP
. 4 FP
8" FP FP
12 FP FIP RC FP
P FP
FIR V FP FP
OE OE
V
188 OE OE
1 OE OE
112
2 OE OE OE OE ARCH I T E C TURE
V LANDS N/F SITE
13 MOLLY B. PHILLIPS FP
1
11
FP T.P.: 2-05-07709-05-6100-00001
FP ENG I NE E R I NG
SOUTH GOVERN
DEED REF.: 7372-0173
14
Y
24"
FP
132
24" 30" ZONING - R8 LANDS N/F
DONALD L. HENRY HWA
Dover, DE
24"
15 1
14
V
FP T.P.: 2-05-07709-05-6000-00001
165 DEED REF.: 5775-0149
SOUTH STATE STREET
16 36" FP ZONING - R8 LANDS N/F HIG
ORS AVENUE
17 V GIA DOWNTOWN
PROPERTIES, LLC FP FP 309 S. Governors Ave.
17 1819
96" V Dover, DE 19904
C-PR-L-TREE-AR
19
T.P.: 2-05-07709-05-5901-00001 NT
18 FP DEED REF.: 8444-0331
UPO Ph. 302.734.7950
5
ZONING - R8
FP V
C-PR-L-TREE-AR
FIP
19 FP
FP Fax 302.734.7965
V
SOU
Salisbury, MD
C-PR-L-TREE-CV
FP
TH
20 20
V
FP
21 V D
C-PR-L-TREE-AR
V 312 West Main St. Suite 300
48"
22
C-PR-L-TREE-C
V
21 FP Xref-Phase-1-Parking-Blk FCM V Salisbury, MD 21801
V
20 Xref-Phase-2-Parking-Blk
Xref-Phase-3-Parking-Blk
Ph. 410.546.9100
23 FP FP Fax 410.546.5824
LOCATION MAP
C-PR-L-TREE-AR
22
FP SCALE : 1" = 1,000'
10 Wilmington, NC
24"
48"
AC
23
24
24 25 FP FP 3205 Randall Parkway, Suite 211
C-PR-L-TREE-AR
18 9 26 SITE DATA Wilmington, North Carolina 28403
EX. 18"S
FP
Ph. 910.341.7600
48" FP
1011
21
25 27 FP 1. OWNER OF RECORD : KGH DEVELOPMENT CORP.
TWO STORY
Fax 910.341.7506
12
FP
BRICK (DEVELOPER) 625 SOUTH STATE STREET
BUILDING 13 4
1 5
LANDS N/F DOVER, DE 19901
www.beckermorgan.com
C-PR-L-TREE-AR
2,743 SQ. FT.
1 6 CITY OF DOVER 302-744-7027
1
C-PR-L-TREE-CV
17 8
T.P.: 2-05-07713-01-5700-00001
22
6
10 1 9 FP DEED REF.: 5011-0121 2. ENGINEER : BECKER MORGAN GROUP INC.
26 1 20
C-PR-L-TREE-C
V
ZONING - IO 309 SOUTH GOVERNORS AVE.
C-PR-L-TREE-CV C-PR-L-TREE-CV C-PR-L-TREE-CV C-PR-L-TREE-C C-PR-L-TREE-C
FP
V V
48"
DOVER, DE 19904
AC 21 2
2 LANDS N/F 302-734-7950
2
2 3 CITY OF DOVER
3. PROPERTY MAP NUMBER : ED-05-077.13-01-51.00
254
23 60"
ONE STORY FP
27 FRAME
T.P.: 2-05-07713-01-5000-00001
2 FP DEED REF.: T-0036-0203
BUILDING 276 4. ZONING CLASSIFICATION : IO - INSTITUTIONAL AND OFFICE (CITY OF DOVER)
C-PR-L-TREE-CV
C-PR-L-TREE-C
ZONING - IO
V
28 1,112 SQ. FT.
SWPOZ TIER 1 AND 3 - SOURCE WATER PROTECTION OVERLAY ZONE
10 34 V 5. USE : EXISTING : OFFICE BUILDINGS AND DAYCARE CENTER
28
24 10 FP FP PROPOSED : PARKING LOT EXPANSION
V
C-PR-L-TREE-CV
6. TOTAL SITE AREA : 11.43 ACRES ± / 497,676.5 S.F. ±
C-PR-L-TREE-CV C-PR-L-TREE-C
V
24"
V
28
29 FP V
FP
GENERAL LANDSCAPE NOTES :
25 29 V
25
60"
30" FP
1. QUALITY AND SIZE OF PLANTS, SPREAD OF ROOTS, AND SIZE OF BALLS SHALL BE IN ACCORDANCE WITH THE
C-PR-L-TREE-CV C-PR-L-TREE-C C-PR-L-TREE-CV
V
C-PR-L-TREE-CV
26 C-PR-L-TREE-CV
FIP
CURRENT STANDARDS OF THE AMERICAN ASSOCIATION OF NURSERYMEN "AMERICAN STANDARDS FOR
30"
27
OE
C-PR-L-TREE-C
V
X OE
X 36
OE
30 21 9
10 NURSERY STOCK."
36"
24" 11
28 265 12
31 24 13
C-PR-L-TREE-C C-PR-L-TREE-CV
V
30" ONE STORY 2. EVERGREEN TREES SHALL HAVE A FULL, WELL-BRANCHED, CONICAL FORM TYPICAL OF THE SPECIES.
C-PR-L-TREE-CV C-PR-L-TREE-C
V
POLE 2 14
290
294 197
245
29
15
26
31 BUILDING
1,440 SQ. FT.
226 16
17 3. ALL DECIDUOUS SHADE TREES SHALL BRANCH A MINIMUM OF 7'-0" ABOVE GROUND LEVEL. TREES SHALL BE
30" ET 15
18
19
20
PLANTED AND STAKED IN ACCORDANCE WITH THE DETAIL SHOWN.
10 30 21
STR
4. PLANT MATERIALS DELIVERED TO THE SITE IN UNCOVERED TRUCKS WILL BE REJECTED.
C-PR-L-TREE-CV C-PR-L-TREE-C C-PR-L-TREE-CV
22
V
C-PR-L-TREE-C
V
23
38 34 "S
E
31 .6
24E
X
5. UNACCEPTABLE PLANT MATERIALS: MATERIALS WHICH HAVE DAMAGED OR CROOKED LEADERS, DEFORMED
TWO STORY 26 GROWTH HABIT, ABRASIONS OF THE BARK, SUN SCALD, WINDBURN, DISFIGURING NOT COMPLETELY CALLUSED
20
60
C-PR-L-TREE-C
V
FRAME BUILDING 25 WILL BE REJECTED. IN ADDITION, TREES HAVING THEIR CENTRAL LEADERS HEADED BACK WILL ALSO BE
C-PR-L-TREE-CV C-PR-L-TREE-C C-PR-L-TREE-CV
V
EX. 6"S
1,044 SQ. FT.
28
FO
2423 FP REJECTED. PLANTS WITH LOOSE OR CRACKED ROOT BALL OR CONTAINERS WILL BE REJECTED.
25
TE
KCR OT W
32 EX. 6"S 23 4 FP
FP
30 29 2 6. ALL PLANTS SHALL BE PLANTED IN TOPSOIL THAT IS THOROUGHLY WATERED AND TAMPED AS BACKFILLING
31
C-PR-L-TREE-CV
32 28
25, IDE R
25 PROGRESSES. NOTHING BUT SUITABLE TOPSOIL, FREE OF DRY SOD, STIFF CLAY, LITTER, STONES IN EXCESS OF
STA 27 26
C-PR-L-TREE-CV C-PR-L-TREE-C C-PR-L-TREE-CV
V
ONE (1) INCH DIAMETER, ETC. SHALL BE USED FOR PLANTING.
C-PR-L-TREE-CV 12" STEEL - MD - 7.13'
C-PR-L-TREE-CV
26 EX. 30" F.M. FP
4" PVC - MD - 2.01'
MIN IG
42 34
27
FP
OR HT O
26 7. MULCH FOR PLANTING BEDS SHALL BE SHREDDED HARDWOOD BARK MULCH UNLESS OTHERWISE SPECIFIED ON
8" PVC - MD - 5.84' 8" PVC - MD - 5.55'
FP
4" PVC - MD - 1.66'
4" PVC - MD - 1.70'
19 4" PVC - MD - 2.34'
13 THE PLANS AND SHALL HAVE NO LEAVES, YOUNG GREEN GROWTH, BRANCHES, TWIGS, GREATER IN DIAMETER
ART F W
8" PVC - MD - 3.84'
C-PR-L-TREE-C
9
V
8" PVC - MD - 3.53'
C-PR-L-TREE-C C-PR-L-TREE-C C-PR-L-TREE-CV C-PR-L-TREE-CV C-PR-L-TREE-CV C-PR-L-TREE-C
OF ½", WEEDS, SHAVINGS OR FOREIGN MATERIAL SUCH AS STONES, ETC. SHALL BE MIXED WITH THE MULCH.
V V V
FP
TH
30" 33
A
ALL SHRUB MASSES SHALL BE PLANTED IN CONTINUOUS MULCHED BEDS WITH A LIGHTLY COMPACTED DEPTH
ERI
AL Y
TWO STORY
STUCCO BUILDING FP OF THREE (3) INCHES. ALL CONTAINER PLANTS ARE TO HAVE ROOTS CUT ON FOUR SIDES AND/ OR SPREAD OUT
34
SOU
2,100 SQ. FT. G.M.
IN NEW SOIL MIXTURE.
C-PR-L-TREE-CV C-PR-L-TREE-CV C-PR-L-TREE-C
V
17 C-PR-L-TREE-C
V
C-PR-L-TREE-CV
26 C-PR-L-TREE-CV C-PR-L-TREE-C
V
8. ALL AREAS NOT STABILIZED IN PAVING OR PLANT MATERIALS SHOULD BE SEEDED AND MULCHED. (SEE EROSION
EXISTING ONE-STORY EX. 18"S & SEDIMENT CONTROL PLAN AND NOTES.)
44 33 32 COVERED
ENTRANCE
BRICK 38
BUILDING 26 FP
31 OUTPATIENT SURGERY CENTER PROJECT TITLE
9. LANDSCAPE BEDS NOT DEFINED BY CURBS, SIDEWALKS, WALLS OR OTHER STRUCTURES SHALL BE ENCLOSED
C-PR-L-TREE-CV
30 17 10,800 S.F. ± - FOOTPRINT BY ALUMINUM EDGING UNLESS OTHERWISE INDICATED.
BAYHEALTH
C-PR-L-TREE-C C-PR-L-TREE-C C-PR-L-TREE-CV C-PR-L-TREE-C C-PR-L-TREE-CV C-PR-L-TREE-CV C-PR-L-TREE-CV
V V V
26
193
27"
29 28 27 26 FP
10. AREAS DISTURBED BY LANDSCAPE OPERATIONS SHALL BE GRADED TO MATCH EXISTING TOPSOIL AND SEED OR
MEDICAL
GEN
SOD AS REQUIRED.
28 W.M. W.V.
W.M.
11. CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO UTILITIES AND MAY MAKE MINOR ADJUSTMENTS IN
CENTER, INC
17 27 19 13
C-PR-L-TREE-CV
C-PR-L-TREE-C C-PR-L-TREE-CV C-PR-L-TREE-CV C-PR-L-TREE-CV
V C-PR-L-TREE-C
V
C-PR-L-TREE-C
C-PR-L-TREE-CV
10 9
V
32 SPACING AND/OR LOCATION OF PLANT MATERIALS. CONTRACTOR TO VERIFY "AS BUILT" LOCATION OF ALL
32 32
33 60" 33 27 AC
UTILITIES.
29 FP ST. JONES RIVER
32 C-PR-L-TREE-AR
C-PR-L-TREE-AR
C-PR-L-TREE-AR
C-PR-L-TREE-AR C-PR-L-TREE-AR
C-PR-L-TREE-AR
C-PR-L-TREE-AR
AC
SCULL PROPERTY
W.V.
C-PR-L-TREE-AR
28 LANDSCAPE 12. NO PLANT, EXCEPT GROUNDCOVER, SHALL BE WITHIN THREE (3) FEET FROM SIDEWALKS.
C-PR-L-TREE-AR
C-PR-L-TREE-AR
C-PR-L-TREE-AR
C-PR-L-TREE-AR
W.V.
31 ONE STORY
30 27 D.
PROJECT
17 19 13FRAME
SITE DEVELOPMENT
30 29 BUILDING 13. NO TREE SHALL BE PLANTED CLOSER THAN TEN (10) FEET FROM ANY STRUCTURE OR BUILDING.
31
28
C-PR-L-TREE-CV
C-PR-L-TREE-CV
C-PR-L-TREE-C
V
C-PR-L-TREE-CV
5,044 SQ. FT.
C-PR-L-TREE-CV
AREA
F.H.
W.V.
32 FP 14. NO TREE SHALL BE PLANTED WITHIN TEN (10) FEET OF UNDERGROUND UTILITIES OR FIRE HYDRANTS. MASTER PLAN
98
AC
27 .M.
33 27
SCULL TERRACE
30"
F
34 33 32 EX.
26
15. ONLY TREES THAT REACH A HEIGHT AND SIZE AT MATURITY OF SMALL TO MEDIUM SHALL BE PLANTED UNDER
POWER LINES. BAYHEALTH STAFF
OE OE
OE C-PR-L-TREE-CV
OE 12
C-PR-L-TREE-CV
18
C-PR-L-TREE-CV C-PR-L-TREE-CV
2020
C-PR-L-TREE-C
V
13
C-PR-L-TREE-CV
FP 16. THE CONTRACTOR SHALL WATER ALL PLANTS THOROUGHLY TWICE DURING THE FIRST 24-HOUR PERIOD
PARKING LOT
26
OE
FCM
OE OE OE
FCM
AFTER PLANTING, AND THEN WEEKLY OR MORE OFTEN, IF NECESSARY, DURING THE FIRST GROWING SEASON,
UNLESS THE OWNER AGREES TO MAINTAIN AND WATER THEM.
EXPANSION
18"
605 S. STATE STREET
C-PR-L-TREE-AR C-PR-L-TREE-AR C-PR-L-TREE-AR C-PR-L-TREE-AR C-PR-L-TREE-AR C-PR-L-TREE-AR
C-PR-L-TREE-AR C-PR-L-TREE-AR C-PR-L-TREE-AR C-PR-L-TREE-AR
24"
17. TREES TO REMAIN ON-SITE SHALL BE PROTECTED WITH SNOW FENCE DURING CONSTRUCTION (SEE DETAIL).
CITY OF DOVER
29
60
45
30
15 0 15
30
45
60
FP
SNOW FENCING TO BE MAINTAINED DURING CONSTRUCTION BY CONTRACTOR.
KENT COUNTY, DELAWARE
75 75
90 90
75 75
60 60
45 45
30 30
15 0 15
18. THE PLANTING PLAN SHALL TAKE PRECEDENCE OVER THE PLANT SCHEDULE SHOULD ANY PLANT QUANTITY
LANDS N/F
DISCREPANCIES OCCUR. SHEET TITLE
CHURCH OF THE HOLY CROSS, DOVER, DELAWARE
S
18"
30
T.P.: 2-05-07713-01-5600-00001
CONCEPT
EX.
30
DEED REF.: Q-0020-0165 19. NO SUBSTITUTIONS SHALL BE MADE WITHOUT APPROVAL OF THE OWNER AND/ OR THE LANDSCAPE ARCHITECT
ZONING - IO FP
AND MUST BE APPROVED BY THE CITY OF DOVER PLANNING DEPARTMENT PRIOR TO INSTALLATION.
LANDSCAPE
30
30
29
2
278 20. ALL NEW TREES SHALL BE GUARANTEED TO SURVIVE FOR ONE FULL YEAR AFTER INSTALLATION (FULL COST).
ALL STAKES AND GUYS SHALL BE REMOVED FROM TREES AND SITE AS EARLY AS THREE (3) MONTHS, BUT NO
MASTER PLAN
OE
LONGER THAN ONE (1) YEAR AFTER PLANTING.
TREE PRESERVATION & DENSITY REQUIREMENTS
NOTE:
1.
2.
EXISTING WOODLAND AREA :
TOTAL PRESERVED WOODLANDS :
N/A
N/A
PHASE 3
DO NOT HEAVILY PRUNE THE TREE
AT PLANTING. PRUNE ONLY 3. TOTAL NON-WOODLAND PROJECT AREA : 6.40 ACRES / 278,779 S.F.
CROSSOVER LIMBS, CO-DOMINANT 4. DENSITY : 1 TREE PER 3,000 S.F. OF NON-WOODLAND AREA
LEADERS, AND BROKEN OR DEAD 317,158.4 S.F. / 1 TREE PER 3000 S.F. = 105.7 TREES 106 TREES REQUIRED
BRANCHES. SOME INTERIOR
5. EXISTING TREES TO BE RETAINED : 14
TWIGS AND LATERAL BRANCHES
MAY BE PRUNED; HOWEVER, DO 6. PROPOSED TREES FOR PROJECT AREA : 122
NOT REMOVE THE TERMINAL BUDS TOTAL TREES PROVIDED 136 0 25 50 100
OF BRANCHES THAT EXTEND TO
THE EDGE OF THE CROWN.
DELAWARE LANDSCAPE ARCHITECTS CERTIFICATION SCALE : 1" = 50'
SET ROOT BALL 2" ABOVE CANVAS WEBBING OR I, CHAD D. CARTER, RLA, ASLA, HEREBY CERTIFY THAT I AM A
GRADE. REMOVE EXCESS
SOIL ON TOP OF THE
PLASTIC HORTICULTURAL
TAPE. DO NOT STRETCH.
LEGEND LANDSCAPE ARCHITECT IN THE STATE OF DELAWARE, THAT THE
LANDSCAPING INFORMATION SHOWN HEREON HAS BEEN PREPARED ISSUE BLOCK
BALL, JUST EXPOSING UNDER MY SUPERVISION AND TO MY BEST KNOWLEDGE AND BELIEF,
THE ROOT FLARE. REPRESENTS GOOD LANDSCAPING PRACTICES.
SET ROOT BALL 2" ABOVE CANVAS WEBBING OR EXISTING TREES
GRADE. REMOVE EXCESS PLASTIC HORTICULTURAL TO BE RETAINED
SOIL ON TOP OF THE TAPE. DO NOT STRETCH.
BALL, JUST EXPOSING
MULCH - PLACE 3" 2"x2" WOODEN THE ROOT FLARE.
LAYER OF SPECIFIED STAKES. DRIVE
DRIP LINE DRIP LINE
MULCH. DO NOT PLACE SECURELY INTO
IN CONTACT WITH TREE GROUND. 3 PER
EXISTING TREES
TRUNK. KEEP MULCH TREE.
WEEDED AND REPLACE MULCH - PLACE 3" 2"x2" WOODEN
TO BE REMOVED
AS NEEDED. FINISHED LAYER OF SPECIFIED STAKES. DRIVE
MULCH. DO NOT PLACE SECURELY INTO NO ENTRANCE INTO CHAD D. CARTER, RLA, ASLA S1-499 DATE
GRADE ROOT ZONE BY YELLOW SAFETY
IN CONTACT WITH TREE GROUND. 3 PER
TRUNK. KEEP MULCH TREE. MACHINERY, PARKING RIBBON AND SILT
WEEDED AND REPLACE OR MATERIALS FENCE AROUND TREES
AS NEEDED. FINISHED STORAGE PR. CANOPY TREE
GRADE MARK DATE DESCRIPTION
C-PR-L-TREE-AR
METAL POSTS LAYER STATE : L-101
PROJECT NO.: 2019184.07
REMOVE TOP 1/3 OF BURLAP. SOIL MIXTURE - CONSISTING OF DATE: 2020-09-04
CUT & REMOVE ALL STRAPPING, 1/4 HUMUS AND 3/4 TOPSOIL PR. FLOWERING TREE
SCALE: 1" = 50'
C-PR-L-TREE-CV
ROPES, AND WIRE CAGES. REMOVE TOP 1/3 OF BURLAP. SOIL MIXTURE - CONSISTING OF
CUT & REMOVE ALL STRAPPING, 1/4 HUMUS AND 3/4 TOPSOIL
NOTE :
UNDISTURBED SOIL
ROPES, AND WIRE CAGES.
DRAWN BY: C.D.C. PROJ. MGR.: M.A.R.
SILT FENCE OR TREE PRESERVATION FENCE TO BE PLACED AROUND
UNDISTURBED SOIL LIMITS OF CLEARING SHEET
PR. EVERGREEN TREE
DECIDUOUS TREE PLANTING DETAIL TREE PROTECTION DETAIL
NO SCALE BMG NO. : L-01
EVERGREEN TREE PLANTING DETAIL
NO SCALE BMG NO. : L-02 NO SCALE BMG NO. : L-02
L-101
COPYRIGHT 2013
125
F:\AutoCAD\Projects\2019\2019184-07\DWG\201918407-LSCAPE-C3d18.dwg, Sep 04, 2020 - 11:03am
Page 126
24x36 24x36
Item 7.
24x36 24x36
ET
TRE
E R S
24x36
LANDS N/F WAT 24x36
MATHEW PERZA LANDS N/F
T.P.: 2-05-07709-05-7101-00001 RICHARD J. KOSIOR
DEED REF.: 8452-0199 & KATHLEEN P. KOSIOR LANDS N/F
24x36
ZONING - R8 T.P.: 2-05-07709-05-7100-00001 MICHAEL GRANT 24x36
N 78° 25' 47 DEED REF.: 5045-0067 & RACHEL GRANT
"E ZONING - R8 T.P.: 2-05-07709-05-6500-00001 LANDS N/F LANDS N/F
FCM FIP DEED REF.: 9012-0298 DENNIS J. GRIMM KATHLEEN M. UNTERKOFLER
T.P.: 2-05-07709-05-6400-00001
75.44' ARCH I T E C TURE
ZONING - R8 T.P.: 2-05-07709-05-6300-00001
26.45' DEED REF.: 5079-0078 DEED REF.: IS-0026-0405
SITE
24x36 24x36
ZONING - R8 ZONING - R8 ENG I NE E R I NG
S AVENUE
FIR
343.96' IGH
KERBIN STREET
338.05' WAY Dover, DE
N 16° 12' 10" W
SIRC S
SOUTH STATE STREET
68
24x36 24x36
°0 T H 309 S. Governors Ave.
T.P.: 2-05-07709-05-5901-00001 LLC
6' Dover, DE 19904
SOUTH GOVERN
48.98' 33 LANDS N/F
LANDS N/F UPO Ph. 302.734.7950
"E LISA MARIE ROSSI N
KGH DEVELOPMENT CORPORATION
GIA DOWNTOWN PROPERTIES,
FIP
T.P.: 2-05-07709-05-6200-00001 Fax 302.734.7965
OR
24x36 24x36
T.P.: 2-05-07713-01-5100-00001 S 78° 48' 37
SOU
"W 1 FIR DEED REF.: 7048-0014
T.P.: 2-05-07709-05-6000-00001
DEED REF.: S-0039-0127 1
Salisbury, MD
TH
8.
10 ZONING - R8
D
SIRC '
DEED REF.: 8444-0331
19,389 S.F.± 312 West Main St. Suite 300
DUSTIN H. WOOD
24x36 24x36
LANDS N/F
Salisbury, MD 21801
SOUTH STREET LANDS N/F
DEED REF.: 5775-0149
MOLLY B. PHILLIPS Ph. 410.546.9100
LANDS N/F
12 Fax 410.546.5824
7. T.P.: 2-05-07709-05-6100-00001
LOCATION MAP
ZONING - R8
16' DEED REF.: 7372-0173 SCALE : 1" = 1,000'
Wilmington, NC
24x36 24x36
PROPERTY LINE TO BE ZONING - R8
ZONING - R8
EXTINGUISHED PER THIS PLAN N 87
° 59' 3333 Jaeckle Drive, Suite 120
1938
32" E
N
65
°5
SITE DATA Wilmington, North Carolina 28403
0.45 9 S.F
Ph. 910.341.7600
24x36 24x36
3'
TE ST
23 1. OWNER OF RECORD: BAYHEALTH MEDICAL CENTER, INC
"W
FIP 640 SOUTH STATE STREET Fax 910.341.7506
AC. .±
N: 420009.82
115.
52'
152.0
9' E: 626824.76
DOVER, DE 19901
www.beckermorgan.com
±
KCR 25,WIDE RIGHT REET
N 77° 42' 04"
24x36 24x36
2. ENGINEER / SURVEYOR: BECKER MORGAN GROUP INC.
E SIRC 309 SOUTH GOVERNORS AVE.
SIRC 50.03' DOVER, DELAWARE 19904
S 88
° 31'
37" W
S 15° 02' 25" E 302-734-7950
"W
24x36 24x36
7.58'
N 16° 19' 35" W
LANDS N/F
FCM
34 ' 47 3. PROPERTY ADDRESS: 605 & 625 SOUTH STATE STREET
.90' 2°
108 S5
DOVER, DE 19901
BAYHEALTH MEDICAL CENTER, INC
32.15'
OF WAY
RADIUS: 1462.69'
ARC LENGTH:284.55'
T.P.: 2-05-07713-01-4900-00001 4. TAX PARCEL NUMBERS: 2-05-07713-01-4900-00001 & 2-05-07713-01-5100-00001
3ACRES±
DEED REF.: 0657-0020
24x36 24x36
3.45 .4
MINOR A
CHD. BRG: N 10° 37' 47" W
5. DEED REFERENCE : D-657-20 & S-39-127
5 AC
CHD. LENGTH: 284.10'
STA
EXISTING CHAINLINK FENCE 6. SITE AREA SUMMARY: P. 49 3.45 ACRES±
. ±
5' P. 51 7.98 ACRES±
74.9
RTERIAL
24x36 24x36
TOTAL AFTER CONSOLIDATION = 11.43 ACRES±
.85' EXISTING CHAINLINK FENCE 7. NUMBER OF LOTS: EXISTING: 2
183 PROPOSED: 1
70.00' S 15° 02' 25" E
SOUTH
24x36 24x36
LANDS N/F LANDS N/F 8. ZONING CLASSIFICATION: IO - INSTITUTIONAL AND OFFICE
60 FOOT
CITY OF DOVER CITY OF DOVER SWPOZ - SOURCE WATER PROTECTION OVERLAY ZONE
T.P.: 2-05-07713-01-5700-00001 T.P.: 2-05-07713-01-5000-00001 (PART OF PARCELS)
DEED REF.: 5011-0121 DEED REF.: T-0036-0203
24x36
ZONING - IO ZONING - IO 9. SETBACKS: IO - INSTITUTIONAL AND OFFICE 24x36
STREET YARD: 10 FEET
SIDE YARD: 10 FEET DSP
REAR YARD: 15 FEET
SIDE/REAR ADJOINING "R" ZONES: 30 FEET
83 /
24x36 24x36
RADIUS: 1462.69' 10. BULK STANDARDS: IO - INSTITUTIONAL AND OFFICE
N 74° 57' 34" E
ARC LENGTH: 462.51'
CHD. BRG: N 7° 08' 39" W 170.01'
MINIMUM AREA:
MINIMUM FRONTAGE:
10,000 SQ. FT.
100 FEET
.NAD
24x36
71.52' 24x36
CHD. LENGTH: 460.59' 98.49' MINIMUM DEPTH: 100 FEET
S 15° 02' 25" E
EXISTING CHAINLINK FENCE BUILDING HEIGHT: 150 FEET/10 STORIES
FLOOR AREA RATIO: 6.0
N
N 16° 19' 35" W
24x36 MAX LOT COVERAGE: 85% 24x36
11. PRESENT USE: MEDICAL FACILITIES
12. ROAD CLASSIFICATION: SOUTH STATE STREET - MINOR ARTERIAL - 25 MPH
13. PROPERTY LOCATION: LATITUDE: N 39° 09' 08.66" GRS80 - NAD83 (2011)
24x36 24x36
N 73° 40' 25" E LONGITUDE: W 075° 31' 16.22" GRS80 - NAD83 (2011)
566.54' FIP 14. SURVEY DATUM: NGS MONUMENTS
VERTICAL: NAVD 88 - DNREC
80.00'
24x36 24x36
HORIZONTAL: NAD 83 (2007) DSP - DNREC
PROPERTY LINE TO BE
EXTINGUISHED PER THIS PLAN SIRC S 87 15. MONUMENTATION: 8 FOUND / 7 SET
TOT ° 29
' 22 16. SURVEY CLASSIFICATION: SUBURBAN SURVEY
AL -
N 73° 01' 53" E "E
24x36 24x36
PROJECT TITLE
28.34' 78.4
11.4
8'
S
LANDS OF
7.53 3 AC
74
BAYHEALTH
24x36 24x36
°5
0'
AC. RES
58
"E
24x36
± ± MEDICAL 24x36
24x36
RADIUS: 1462.69'
ARC LENGTH:177.96'
CHD. BRG: N 1° 34' 16" W
CENTER, INC 24x36
CHD. LENGTH: 177.86'
24x36 24x36
18
LANDS N/F 3.8
8'
24x36
KGH DEVELOPMENT CORPORATION 24x36
T.P.: 2-05-07713-01-5100-00001 605 & 625 SOUTH STATE STREET
DEED REF.: S-0039-0127
S 34 CITY OF DOVER
7.53 ACRES± KENT COUNTY, DE
24x36 24x36
SDH
° 35
.88'
184 ' 27" SHEET TITLE
24x36 24x36
E
AREA AFTER CONSOLIDATION LOT
11.43 ACRES±
CONSOLIDATION
RIVE
24x36 24x36
PLAN
R
24x36 24x36
ONES
24x36 24x36
24x36 24x36
0 20 40 80
ST. J
24x36
176 24x36
.50' Do Not Explode - Select Scale
SCALE: 1" = 40'
E
34" N 78° 28' 32
"E
37.87'
24x36 24x36
POB 34' ISSUE BLOCK
N: 419257.99
E: 626242.16 N 1°
24x36
FCM FCM 121.55' S 11° 54' 41" E 24x36
SDH 1115.96' S 72° 59' 55" W
25.33'
N: 419548.78
LANDS N/F E: 627193.12
CHURCH OF THE HOLY CROSS, DOVER, DELAWARE
24x36 24x36
T.P.: 2-05-07713-01-5600-00001
DEED REF.: Q-0020-0165
ZONING - IO
24x36 24x36
SURVEY LEGEND GENERAL NOTES : .
C-1-NOTES-LEGEND-SURVEY
ITEM EXISTING PROPOSED . . .
24x36
1. THE PURPOSE OF THIS PLAN IS TO CONSOLIDATE PARCELS 2-05-07713-01-4900-00001 & 24x36
2-05-07713-01-5100-00001, IN TO ONE PARCEL. PARCELS OWNED BY BAYHEALTH MEDICAL CENTER, INC, MARK DATE DESCRIPTION
UNMARKED POINT LAYER STATE: 24x36
AND IS MORE PARTICULARLY DESCRIBED IN D.R. 1017-127 AS RECORDED IN THE KENT COUNTY
CONCRETE MONUMENT FCM SCM
SURVEYOR CERTIFICATION OWNERS CERTIFICATION RECORDER OF DEEDS. PROJECT NO.: 2019184.07
IRON PIPE FIP SIP 2. THE BOUNDARY & TOPOGRAPHIC DATA SHOWN HEREON WAS COMPILED FROM A FIELD SURVEY
DATE: 08/27/2020
24x36 24x36
I, JEFFREY C. DODD, REGISTERED AS A PROFESSIONAL LAND SURVEYOR IN THE STATE OF DELAWARE, HEREBY WE, BAYHEALTH MEDICAL CENTER, INC. HEREBY CERTIFY THAT WE ARE THE OWNER OF THE PROPERTY PERFORMED BY BECKER MORGAN GROUP, INC. , DOVER, DE. IN MARCH 2020
IRON PIPE W/ CAP FIPC
STATE THAT THE INFORMATION SHOWN ON THIS PLAN HAS BEEN PREPARED UNDER MY SUPERVISION AND DESCRIBED AND SHOWN ON THIS PLAN, THAT THE PLAN WAS MADE AT OUR DIRECTION, AND THAT WE
IRON ROD FIR SIR MEETS THE STANDARDS OF PRACTICE AS ESTABLISHED BY THE STATE OF DELAWARE BOARD OF ACKNOWLEDGE THE SAME TO BE OUR ACT AND DESIRE THE PLAN TO BE DEVELOPED AS SHOWN IN
3. THE BOUNDARY LINES PORTRAYED HEREON HAVE BEEN ESTABLISHED BASED SOLELY ON PHYSICAL SCALE: 1" = 40'
EVIDENCE DISCOVERED IN THE FIELD, IN CONJUNCTION WITH DETERMINATIONS DERIVED FROM SOURCE
PROFESSIONAL LAND SURVEYORS. ANY CHANGES TO THE PROPERTY CONDITIONS, IMPROVEMENTS, ACCORDANCE WITH ALL APPLICABLE LAWS AND REGULATIONS.
IRON ROD W/ CAP FIRC SIRC OF TITLE AND ADJACENT DEED RECORD INFORMATION. DRAWN BY: J.H.K. PROJ. MGR.: J.C.D.
24x36 24x36
BOUNDARY OR PROPERTY CORNERS AFTER THE DATE SHOWN HEREON SHALL NECESSITATE A NEW REVIEW
DRILL HOLE FDH SDH AND CERTIFICATION FOR ANY OFFICIAL OR LEGAL USE. 4. PROPERTY SHOWN HEREON IS SUBJECT TO ANY RIGHT-OF-WAY, EASEMENTS, RESTRICTIONS, ETC. AS SHEET
MAY BE SHOWN OR NOTED IN ANY RECORD, PUBLIC OR OTHERWISE, OR ANY REQUIREMENT OR
1 OF 1
STONE FSTONE REGULATION OF ANY PUBLIC AGENCY.
24x36 24x36
PK NAIL FPK SPK 5. THIS PARCEL IS LOCATED WITHIN ZONE "X", AREA OF MINIMAL FLOOD HAZARD, BASED ON FIRM MAP
JEFFREY C. DODD P.L.S.NO. 782 DATE BAYHEALTH MEDICAL CENTER, INC DATE FLOOD ELEVATION 9.0', BASED ON FIRM MAP 10001C0169J, PANEL 169, REVISED JULY 7, 2014.
COPYRIGHT 2020
126
24x36
F:\AutoCAD\Projects\2019\2019184-07\DWG\201918407-Consolidation Plan-C3D18.dwg, Aug 27, 2020 - 11:04am 24x36
2020-08-27